INDOT Wall System Approval Criteria and Design Review

Yuhui Hu, P.E. Office of Geotechnical Services, INDOT

March 12, 2014

Slide 1

Page 2: INDOT Wall System Approval Criteria and Design Review

Outline

Types of earth retaining structures

Types of Mechanically Stabilized Earth walls (MSE walls)

Criteria for approving wall system

MSE Wall project design review

Slide 2

Page 3: INDOT Wall System Approval Criteria and Design Review

Types of Earth Retaining Structures Wall Development

Reinforced concrete (rigid) structure – gravity wall

Gravity wall

Slide 3

Page 4: INDOT Wall System Approval Criteria and Design Review

Cantilever wall

Backfill

Slide 4

Types of Earth Retaining Structures Wall Development

Cantilever wall: semi-gravity

Page 5: INDOT Wall System Approval Criteria and Design Review

Types of Earth Retaining Structures Wall Development

Mechanically Stabilized Earth wall includes three components:

Structural backfill

Reinforcement

Facing

Reinforced Backfill

Slide 5

Reinforcement

Facing

Page 6: INDOT Wall System Approval Criteria and Design Review

Types of MSE Wall Category

Precast concrete panel type of MSE wall with extensible or inextensible reinforcement

Inextensible reinforcement

Extensible reinforcement

Note: Current Indiana specification only allows inextensible

reinforcement.

Slide 6

Page 7: INDOT Wall System Approval Criteria and Design Review

Types of MSE Wall Category

Modular block wall with typical extensible reinforcement

Dry-cast block

Dry-cast block wall without reinforcement – gravity wall

Dry-cast block wall with reinforcement – MSE wall

Wet-cast block

Large-size block without reinforcement – gravity wall

Large-size block with reinforcement – MSE wall

Slide 7

Page 8: INDOT Wall System Approval Criteria and Design Review

Precast panel MSE wall

Steel Reinforcement

Economical in fill areas

Lighter in weight

Tolerate more settlement

Massive block wall

No reinforcement

Economical in cut areas

Heavier in weight

Tolerate relatively less settlement

Slide 8

Conclusion: Large block wall shall follow gravity wall design.

Massive Block Wall vs. MSE Wall

Page 9: INDOT Wall System Approval Criteria and Design Review

Comparison

Precast panel MSE wall

Steel reinforcement

Tested mechanical connection strength

Settlement tolerance 1/100

Need evaluation for approval to use

Wet-cast block wall with reinforcement

Geosynthetic reinforcement

Wrap around blocks or pure friction

Settlement tolerance 1/200

Need evaluation for application

Conclusion: Evaluation needed before wet cast block wall with reinforcement could be used.

Slide 9

Page 10: INDOT Wall System Approval Criteria and Design Review

Block Wall Criteria

INDOT criteria for using modular block walls:

Maximum wall height without reinforcement: 5 Feet

Reinforced block wall height limit: 15 Feet

Modular block walls could be used only for non-critical application

Slide 10

Page 11: INDOT Wall System Approval Criteria and Design Review

Other State’s Criteria

Minnesota DOT:

Wet-cast gravity block walls maximum height without reinforcement: 8 feet

Gravity block walls shall not support traffic

Reinforced block wall height limit: 18 feet

Slide 11

Page 12: INDOT Wall System Approval Criteria and Design Review

Slide 12

Wall Design Height (Hd)

Page 13: INDOT Wall System Approval Criteria and Design Review

Effect of Settlement on Wall

Longitudinal settlement along wall facing: Panel may crack, gap between panels exposed.

Settlement perpendicular to wall front face: The reinforcement connection may be overstressed.

Slide 13

Page 14: INDOT Wall System Approval Criteria and Design Review

Typical MSE Wall Problems

Slide 14

Page 15: INDOT Wall System Approval Criteria and Design Review

Slide 15

Typical MSE Wall Problems

Page 16: INDOT Wall System Approval Criteria and Design Review

Slide 16

Typical MSE Wall Problems

Page 17: INDOT Wall System Approval Criteria and Design Review

Slide 17

Typical MSE Wall Problems

Page 18: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

Approval MSE walls system:

Precast reinforced concrete panel

Galvanized steel reinforcement

Mechanical connection

Slide 18

Page 19: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

Link to the website of wall approval list: http://www.in.gov/indot/div/mt/appmat/pubs/apl33.pdf

Slide 19

Page 20: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System Benefits of establishment of pre-approval list

of MSE wall: Past successful experience of the system in public

transportation projects, if any.

Information of possible failure/disadvantages of the system.

Structural strength of the components.

Reliable system components’ configuration.

Project design review.

Slide 20

Page 21: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

Indiana Test Method 806, No. 14, Procedure J requires the following:

Highway Innovative Technology Evaluation Center (HITEC) Evaluation Report

Pullout tests to confirm pullout performance is in lieu of the performance of reinforcement in AASHTO LRFD Bridge Design Specifications Figure 11.10.6.3.2-1

Slide 21

Page 22: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

Indiana Test Method 806, No. 14 Procedure J requires (cont’d): Conditional approval with two-year monitoring

program

Other information requested by Office of Geotechnical Services

Type A Certification

Shop drawings and design samples with hand calculation verification

Slide 22

Page 23: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

Revisions to approval criteria:

An alternative approach to HITEC Evaluation Report: evaluation report from independent evaluators

Conditional approval with two-year monitoring program

Pullout test procedures

Slide 23

Page 24: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

HITEC evaluation

It accepts both high-tech and low-tech products.

The evaluation includes multiple consultant’s evaluation and each of them may request additional documentation and/or product test results.

Slide 24

Page 25: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

HITEC evaluation report includes:

Features which may NOT meet AASHTO Standards.

Both design and construction of subject wall system.

All components of wall system and performance of the wall as a structure.

Slide 25

Page 26: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

HITEC to expert’s evaluation report:

Alternate to HITEC

HITEC transition.

After discussing with other states and FHWA.

Maintain HITEC evaluation quality while reducing the costs and time.

Slide 26

Page 27: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

Criteria for selecting evaluators:

HITEC panelist and/or consultants

AASHTO T-15 (Retaining Wall Subcommittee) Technical Advisors

National Highway Institute (NHI) MSE Wall design and construction course instructors and FHWA MSE Wall Manual authors/technical consultants

Selected as evaluators by other states

Publications in retaining wall industry

Slide 27

Page 28: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

INDOT list of wall system evaluators:

Ryan Berg

Barry Christopher

James Collin

Dov Leshchinsky

Slide 28

Page 29: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

Recent changes to approval criteria:

Two-year monitoring program for two projects .

Daily readings during construction, weekly monitoring after completion of construction for 12 weeks, then monthly readings for 24 months.

Slide 29

Page 30: INDOT Wall System Approval Criteria and Design Review

Criteria for Approving Wall System

Possible future revisions to approval criteria:

Pullout tests requirement to determine friction factor F*

Factors affecting F* values:

Test scale

Structural backfill grain sizes

Steel dilation

Details about pullout test procedures – under research

Slide 30

Page 31: INDOT Wall System Approval Criteria and Design Review

Slide 31

Typical MSE Wall Problems

Page 32: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Establish project requirements

Wall geometry

Loading conditions

Performance criteria

Slide 32

Page 33: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Loading conditions

Soil surcharge

Live load

Dead load

Seismic

Traffic barrier impact

Slide 33

Page 34: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Traffic barrier impact verification

AASHTO 11.10.10.2 specify that traffic barriers, constructed over or in line with the front face of the wall, shall be designed to resist overturning moments by their own mass.

INDOT Spec: When traffic barriers are constructed above a MSE Wall or reinforced backfill envelope, the wall shall be designed for extreme event II limit state.

Slide 34

Page 35: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Wall design

External stability

Internal stability

Global stability

Slide 35

Page 36: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Wall external stability

Bearing capacity

Sliding

Limiting eccentricity (overturning)

Slide 36

Page 37: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Wall internal stability

Tension rupture

Connection strength

Pullout

Slide 37

Page 38: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Wall internal stability

Coherent gravity method

Simplified method

Structure stiffness method

alTT max alTT max

calRTT max

Slide 38

Demand (Factored Load) Capacity(Factored Resistance)

Page 39: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Wall external and internal stability

Capacity vs. demand ratio should be always no less than 1.0 (CDR>=1)

alTT max alTT max alTT max

Slide 39

Page 40: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Wall global stability

Factor of safety

Slide 40

Page 41: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Shop drawings

AASHTO LRFD bridge design specification

INDOT approved wall system configurations

Slide 41

Page 42: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Corrosion of galvanized steel

Corrosion calculation for wall steel reinforcement and connectors: Theoretical structural strength – is that always reliable?

Slide 42

Page 43: INDOT Wall System Approval Criteria and Design Review

Slide 43

MSE Wall Project Design Review

Page 44: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Pullout friction factor F* values

All MSE Wall system shall refer to AASHTO Figure 11.10.6.3.2-1 for pullout friction factor F*.

Slide 44

Page 45: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Structural backfill properties

Internal friction angle shall be 34 degree for internal stability analysis.

Unit weight shall be at least 120 lbs/ft3.

Free of organics (1% max.)

Slide 45

Page 46: INDOT Wall System Approval Criteria and Design Review

Slide 46

Typical MSE Wall Problems

Page 47: INDOT Wall System Approval Criteria and Design Review

Slide 47

Typical MSE Wall Problems

Page 48: INDOT Wall System Approval Criteria and Design Review

Slide 48

Typical MSE Wall Problems

Page 49: INDOT Wall System Approval Criteria and Design Review

Slide 49

Typical MSE Wall Problems

Page 50: INDOT Wall System Approval Criteria and Design Review

MSE Wall Project Design Review

Design redundancy should be ensured by construction quality control.

Slide 50

Page 51: INDOT Wall System Approval Criteria and Design Review

Construction Quality

Coarse aggregate compaction

Geotextile

Steel reinforcement get around obstruction

Slide 51

Page 52: INDOT Wall System Approval Criteria and Design Review

Slide 52

Typical MSE Wall Problems

Page 53: INDOT Wall System Approval Criteria and Design Review

Slide 53

Typical MSE Wall Problems

Page 54: INDOT Wall System Approval Criteria and Design Review

Slide 54

Get Around Obstruction

Page 55: INDOT Wall System Approval Criteria and Design Review

Slide 55

Recommendations for Future

Possible use of geosynthetic reinforcement in MSE walls.

Possible raising modular block wall height limit.

Possible use of modular block walls for critical application not supporting any structures.

Develop a list of approved modular block wall systems.

Use Only Simplified Methods for design

CDR to be provided for each reinforcement elevation

Page 56: INDOT Wall System Approval Criteria and Design Review

Acknowledgements

FHWA

AASHTO

Minnesota Department of Transportation

North Carolina Department of Transportation

Ohio Department of Transportation

Washington State Department of Transportation

SGI Testing Services, LLC

Adama Engineering, Inc.

Slide 56

Page 57: INDOT Wall System Approval Criteria and Design Review

Questions?

Slide 57