indirect-fired air heaters cub 200/300/300 hd 300 hd...indirect-fired air heaters cub 200/300/300 hd...

68
Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0 1 7 0 8 9 3 E N

Upload: others

Post on 15-Aug-2020

5 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Indirect-fired Air Heaters

Cub 200/300/300 HD

OPERATOR’S MANUAL

0170893en 006

0809

0 1 7 0 8 9 3 E N

Page 2: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm
Page 3: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Foreword

1 Foreword

CALIFORNIAProposition 65 Warning:

Engine exhaust, some of its constituents, and certain vehiclecomponents, contain or emit chemicals known to the State ofCalifornia to cause cancer and birth defects or other reproductiveharm.

This manual provides information and procedures to safely operateand maintain this Wacker Neuson model. For your own safety andprotection from injury, carefully read, understand and observe thesafety instructions described in this manual.

Keep this manual or a copy of it with the machine. If you lose thismanual or need an additional copy, please contact Wacker NeusonCorporation. This machine is built with user safety in mind; however, itcan present hazards if improperly operated and serviced. Followoperating instructions carefully! If you have questions about operatingor servicing this equipment, please contact Wacker NeusonCorporation.

The information contained in this manual was based on machines inproduction at the time of publication. Wacker Neuson Corporationreserves the right to change any portion of this information withoutnotice.

All rights, especially copying and distribution rights, are reserved.

Copyright 2009 by Wacker Neuson Corporation.

No part of this publication may be reproduced in any form or by anymeans, electronic or mechanical, including photocopying, withoutexpress written permission from Wacker Neuson Corporation.

Any type of reproduction or distribution not authorized by WackerNeuson Corporation represents an infringement of valid copyrightsand will be prosecuted. We expressly reserve the right to maketechnical modifications, even without due notice, which aim atimproving our machines or their safety standards.

WARNING

wcghi_tx000001gb diesel.fm 3

Page 4: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Foreword

Notes:

wcghi_tx000001gb diesel.fm 4

Page 5: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Table of Contents

1. Foreword 3

2. Safety Information 7

2.1 Operating Safety .................................................................................. 72.2 Operator Safety while using Combustion Burners ............................... 82.3 Service Safety ...................................................................................... 82.4 Label Locations .................................................................................. 102.5 Label Descriptions .............................................................................. 11

3. Operation 15

3.1 System Description ............................................................................ 153.2 Installing the Lift Brackets .................................................................. 153.3 System Component Locations ........................................................... 163.4 Mounting the Handle and Base Assembly ......................................... 173.5 Machine Location ............................................................................... 183.6 Suggested Venting ............................................................................. 183.7 Connecting Power to the Machine ..................................................... 203.8 Preliminary Checks ............................................................................ 203.9 Control Panel ...................................................................................... 213.10 Starting the Machine .......................................................................... 223.11 Starting the Machine in (Extreme) Cold Weather ............................... 233.12 Shutting Down the Machine ............................................................... 243.13 Using the Remote Thermostat ........................................................... 25

4. Maintenance 27

4.1 Periodic Maintenance Schedule ......................................................... 274.2 Removing and Installing the Burner Assembly ................................... 284.3 Replacing the Burner Nozzle .............................................................. 304.4 Replacing the Fuel Filter .................................................................... 314.5 Inspecting and Aligning the Burner Electrodes .................................. 324.6 Inspecting and Cleaning the Cadmium (CAD) Cell ............................ 334.7 Checking and Adjusting the Fuel Pressure ........................................ 344.8 Cleaning the Fan Blades and Motor ................................................... 364.9 Cleaning the Interior Shell .................................................................. 374.10 Inspecting the Flame Head ................................................................ 38

ghi_bo0170893en_006TOC.fm 5

Page 6: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Table of Contents

4.11 Inspecting the Electrical Connections .................................................394.12 Fuel Blend Guide .................................................................................394.13 Transporting ........................................................................................404.14 List of Abbreviations ............................................................................414.15 Troubleshooting ...................................................................................424.16 Cub 200/300 Wiring Schematic ...........................................................444.17 Cub 300 HD Wiring Schematic ............................................................444.18 Schematic Legend ...............................................................................45

5. Technical Data 47

5.1 Machine Technical Data ......................................................................47

ghi_bo0170893en_006TOC.fm 6

Page 7: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Safety Information

2 Safety Information

This manual contains DANGER, WARNING, CAUTION, NOTICE, andNOTE callouts which must be followed to reduce the possibility ofpersonal injury, damage to the equipment, or improper service.

This is the safety alert symbol. It is used to alert you to potentialpersonal injury hazards. Obey all safety messages that follow thissymbol to avoid possible injury or death.

DANGER indicates a hazardous situation which, if not avoided, willresult in death or serious injury.

WARNING indicates a hazardous situation which, if not avoided, couldresult in death or serious injury.

CAUTION indicates a hazardous situation which, if not avoided, couldresult in minor or moderate injury.

NOTICE: Used without the safety alert symbol, NOTICE indicates asituation which, if not avoided, could result in property damage.

Note: Contains additional information important to a procedure.

2.1 Operating Safety

Familiarity and proper training are required for the safe operation ofequipment! Equipment operated improperly or by untrained personnelcan be dangerous! Read the operating instructions contained in thismanual and familiarize yourself with the location and proper use of allcontrols. Inexperienced operators should receive instruction fromsomeone familiar with the equipment before being allowed to operatethe machine.

2.1.1 Be sure the machine is on a firm, level surface and will not tip, roll,slide, or fall while operating.

2.1.2 NEVER start a machine in need of repair.

DANGER

WARNING

CAUTION

WARNING

wcghi_si000212gb.fm 7

Page 8: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Safety Information Cub 200/300/300 HD

2.1.3 Keep unauthorized personnel, children, and pets away from the

machine.

2.1.4 Always operate machine with all safety devices and guards in placeand in working order. Do not modify or defeat safety devices. Do notoperate machine if any safety devices or guards are missing orinoperative.

2.1.5 NEVER run the machine indoors or in an enclosed area unlessadequate ventilation, through such items as exhaust fans or hoses, isprovided and if local and national codes permit. Exhaust from theburner contains poisonous carbon monoxide gas. Exposure to carbonmonoxide can cause loss of consciousness and may lead to death.

2.1.6 Do not smoke while operating the machine.

2.1.7 NEVER run the machine in areas that contain flammable objects,fuels, or products that produce flammable vapors.

2.1.8 NEVER connect ductwork between the exhaust outlet port and thesupply air inlet port.

2.1.9 NEVER block the air inlet or outlet.

2.1.10 The installation of this machine must be in accordance with theregulations put forth by all governing bodies having jurisdictionincluding the Canadian Standard B139.

2.2 Operator Safety while using Combustion Burners

2.2.1 Refill the fuel tank in a well-ventilated area.

2.2.2 Replace the fuel tank cap after refueling.

2.2.3 DO NOT spill fuel when refueling the machine. Clean up spilled fuel immediately.

2.2.4 DO NOT smoke when refueling machine.

2.2.5 DO NOT refuel a hot or running machine.

2.2.6 The machine must be installed by qualified personnel who have read and understand all supplied manuals and instructions.

2.2.7 When operating the machine indoors, install a carbon monoxidedetector in the work area according to the detector manufacturer’sinstructions.

2.2.8

2.3 Service Safety

HIGH VOLTAGE! This unit uses high voltage circuits capable ofcausing serious injury or death. Only a qualified electrician shouldtroubleshoot or repair electrical problems occurring with thisequipment.WARNING

wcghi_si000212gb.fm 8

Page 9: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Safety Information

2.3.1 ALWAYS replace the safety devices and guards after repairs andmaintenance.

2.3.2 Keep the machine clean and labels legible. Replace all missing andhard-to-read labels. Labels provide important operating instructionsand warn of dangers and hazards.

2.3.3 ALWAYS make sure slings, chains, hooks, ramps, jacks, and othertypes of lifting devices are attached securely and have enough weight-bearing capacity to lift or hold the machine safely. Always remainaware of the location of other people in the area when lifting themachine.

2.3.4 ALWAYS replace or repair electrical components with componentsthat are identical in rating and performance as the original component.

2.3.5 Do not use gasoline or other types of fuels or flammable solvents toclean parts, especially in enclosed areas. Fumes from fuels andsolvents can become explosive.

2.3.6 Always wear protective epuipment when servicing the machine. Somemachine components may be hot and contain hot fluids.

2.3.7 Notes:

wcghi_si000212gb.fm 9

Page 10: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Safety Information Cub 200/300/300 HD

2.4 Label Locations

wcghi_si000212gb.fm 10

Page 11: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Safety Information

2.5 Label Descriptions

Ref. Label Label Text

1 Danger! Hazardous voltage. Do not oper-ate without this cover in place. Disconnect and lock out power source before opening panel. Could cause severe injury or death.

2 Warning: Blower can automatically start which can cause serious injury. Disconnect power source before servicing.

3 Warning: Blower can automatically start which can cause serious injury. Disconnect power source before servicing.

WARNING

WARNUNG

ADVERTENCIA

AVERTISSEMENT

177370

wcghi_si000212gb.fm 11

Page 12: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Safety Information Cub 200/300/300 HD

4 Using a heater indoors can kill you in min-utes. Heater exhaust contains carbon mon-oxide. This is a poison you cannot see or smell. During indoor operation, vent exhaust gas outdoors. Refer to Operator's Manual.

5 Warning: Electric shock hazard. Disconnect power before servicing. Read Operator’s Manual.

6 Danger: To avoid injury from moving parts, shut off the equipment before removing this cover.

7 Caution: This machine uses diesel fuel.

8 Hot surface hazard!

9 Caution: Lift point.Attach lifting device in this location.

Ref. Label Label Text

DANGERTO AVOID INJURY FROM

MOVING PARTS, SHUT OFF THE EQUIPMENT BEFORE REMOVING THIS COVER.

D

DIESEL

CAUTIONVORSICHT

PRECAUCIONPRECAUCION

CAUTION

VORSICHTPRECAUCION

PRECAUTION

wcghi_si000212gb.fm 12

Page 13: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Safety Information

10 Diesel fuel blend guide. This label indicates the recommended fuel blending values for diesel fuel usage.

11 Tie-down point.

12 Machine rating label: This label indicates rating information for the machine.

13 Weight/mass label: This label indicates the total weight of the machine, including the trailer and a full fuel tank.

14 Model and serial number label: This label shows the model name and the serial num-ber for the heat exchanger on your machine.

Ref. Label Label Text

wcghi_si000212gb.fm 13

Page 14: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Safety Information Cub 200/300/300 HD

15 A nameplate listing the model number, item number, revision number, and serial num-ber is attached to each unit. Please record the information found on this plate so it will be available should the nameplate become lost or damaged. When ordering parts or requesting service information, you will always be asked to specify the model num-ber, item number, revision number, and serial number of the unit.

16 Schematic label. This label, located behind the control panel, shows the electrical schematic for the machine.

17 Installation and instruction label. This label shows installation and operation instruc-tions for the unit.

18 Center of gravity.

Ref. Label Label Text

wcghi_si000212gb.fm 14

Page 15: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Operation

3 Operation

3.1 System Description

The Cub series Air Heater machines are indirect-fired air heaters. TheCub series Air Heater machines incorporate aluminized steel shellsand heat exchangers. The machines run on three fuel options: diesel,Kerosene, or winter blend diesel (winter blend diesel is treated withanti-gelling conditioners for use in cold weather). The fuel is consumedin a closed combustion chamber. The exhaust gasses must be ventedoutdoors through a vent pipe. The clean, dry hot air is recirculated bymeans of an enclosed blower. The Cub series Air Heater machines are intended to heat air onconstruction sites and in other rugged environments. Do not use themachines for any other purpose.

3.2 Installing the Lift Brackets

See graphic ghi_gr005931Before attempting to lift the Cub 200 and 300 models, the lift bracketsmust be installed.

3.2.1 Remove the machine from the crate. 3.2.2 Intstall the four lift brackets (a) as shown using the supplied bolts and

washers.

wcghi_tx000720gb.fm 15

Page 16: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Operation Cub 200/300/300 HD

3.3 System Component Locations

Ref Component Ref Component

1 Fuel tank 2 Air outlet

3 Flue collar (vent) 4 Burner access panel

5 Handle (and base) 6 Control panel

7 Blower 8 Fuel oil filter

9 Lifting device 10 Duct adapter

wcghi_tx000720gb.fm 16

Page 17: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Operation

3.4 Mounting the Handle and Base Assembly

See graphics: wcghi_003991 and ghi_gr005319The Cub series Air Heater machines are shipped partially assembled.Before operating either machine, use the following procedure to mountthe handles and base assembly. This assembly includes the handle,base support, and wheels with axles. Note: There are pre-drilled bolt holes for all the components installedwithin this procedure.Note: The Cub 300 HD requires that only the handle be attached.Refer to the procedure below to install the handle.

3.4.1 Attach the axles to the sides of the fuel tank using the supplied boltsand washers.

3.4.2 Install the wheels using a rubber mallet to secure them to the axleends.

3.4.3 Attach the base support to the rear of the fuel tank using the suppliedbolts and washers.

3.4.4 Attach the handle to the machine using the supplied bolts (andwashers, if applicable).

wcghi_tx000720gb.fm 17

Page 18: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Operation Cub 200/300/300 HD

3.5 Machine Location

The Air Heater machines may be located outdoors or in anyenvironment that requires heating. When locating a machine within thearea to be heated, the exhaust gases must be vented to the outdoors. The machines must be installed:• By qualified personnel who have read and understood all

supplied instructions.• On a flat, firm surface.• With the following minimum clearances:

• 3.05 m (10 ft.) to front.• 0.61 m (2 ft.) to rear.• 0.61 m (2 ft.) to sides.• 1.52 m (5 ft.) to top.• 0.915 m (3 ft.) to flue pipe.

3.6 Suggested Venting

See Graphic: wcghi_gr003990Exhaust gas from this machine CAN KILL YOU IN MINUTES. Theexhaust contains carbon monoxide, a deadly poison you can not seeor smell. This machine must be properly vented to reduce the risk ofcarbon monoxide poisoning.

When installing vents:• Adhere to all local and national codes.• Consult all appropriate governing bodies or local contractor for

venting and fresh air requirements.• Place the machine in a manner that avoids excessive vent bends

(elbows), and long horizontal runs.• Keep air inlets and outlets free from obstruction. • Route the venting pipes in a manner that avoids any flammable

material. • Route the venting pipes in a manner that avoids contact with

humans.

WARNING

wcghi_tx000720gb.fm 18

Page 19: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Operation

Exhaust gas from this machine CAN KILL YOU IN MINUTES. Theexhaust contains carbon monoxide, a deadly poison you can not seeor smell. This machine must be properly vented to reduce the risk ofcarbon monoxide poisoning.

• The above venting diagram shows suggested venting layouts only. Consult all appropriate governing bodies or local contractor for venting and fresh air requirements.

WARNING

wcghi_tx000720gb.fm 19

Page 20: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Operation Cub 200/300/300 HD

3.7 Connecting Power to the Machine

Fire and electric shock hazard. High voltage can cause severe injuryor death. This unit must be electrically grounded. Do NOT useadapters.

The Air Heater machines come equipped with power cords. Connectthe power cord to a grounded outlet rated for 115V, 60 Hz, 15A.

3.8 Preliminary Checks

Before starting the machine, check the following:• Fuel supply on diesel burning machines. See Fuel Blend Guide.• Position of power switch. It must be in the Off (“O”) position.• Power supply. The machine must be connected to a 115V 60Hz

power supply.• Machine location. Ensure that the machine is properly located

according to the Machine Location guidelines in this manual.• Remote thermostat connection. If the remote thermostat will not

be used, the remote thermostat receptacle cover must be installed.

WARNING

wcghi_tx000720gb.fm 20

Page 21: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Operation

3.9 Control Panel

Ref Component Function

a Remote thermostat receptacle

The remote thermostat receptacle (shown with protective cap installed) is used for connecting an optional remotethermostat

b Burner fault lamp and reset button (dual function).

The dual function burner fault lamp and reset button:• illuminates red when the burner has

faulted.• resets the machine when pressed.

c Power switch The power switch provides power to the machine.

d Power cord The power cord provides a means of connecting the machine to a 115V 60 Hz receptacle.

e Power indicator lamp The power indicator lamp illuminates green when the power cord is connected to a 115V 60 Hz receptacle.

wcghi_tx000720gb.fm 21

Page 22: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Operation Cub 200/300/300 HD

3.10 Starting the Machine

3.10.1 Perform the necessary preliminary checks. See section PreliminaryChecks.

3.10.2 If using the remote thermostat, connect it to the control panel at theremote thermostat receptacle. Place the remote thermostat in the areato be heated. Set it to the desired temperature.Note: If the ambient temperature is below 32°F (0°C), it may benecessary to preheat the fuel. See section Preheating the Fuel Filterand Nozzle Heater.

3.10.3 Move the power switch to the On “I” position. • The blower will turn on immediately.• The burner will go through a prepurge cycle and then light.• The burner will continue to fire until the temperature of the space

being heated reaches the temperature set by the thermostat. At that time, the burner shuts down but the blower will remain on.

• If not using the remote thermostat, the blower will continue to operate until shutdown.

wcghi_tx000720gb.fm 22

Page 23: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Operation

3.11 Starting the Machine in (Extreme) Cold Weather

In temperatures below 32°F (0°C), it may be necessary to preheat thefuel inside the fuel filter canister. The fuel filter and nozzle contain low-wattage heating elements that are controlled by a thermostat and arespecifically designed for this purpose.

Hot surface hazard. The external surface of the fuel filter may be hot. • Wear safety gloves when handling the fuel filter.

Note: Excess heating may increase the need for maintenance. Seesections “Replacing the Fuel Filter” and “Replacing the Burner Nozzle”.To preheat the fuel, carry out the following procedure.

3.11.1 Connect power to the machine. See section Connecting Power to theMachine.

3.11.2 Wait 20-30 minutes—longer for colder temperatures. 3.11.3 Start the machine. See section Starting the Machine.

Note: In extreme wind, the machine may need to be temporarilyblocked from the wind in order to start.

3.11.4 If the burner does not start on the first attempt, allow the power-onsequence to cycle again (see 3.10.3).

3.11.5 If, after the second power-on sequence completes, the machine willnot fire, move the power switch to the off position.

3.11.6 Wait another 20-30 minutes and attempt to start the machine again.

CAUTION

wcghi_tx000720gb.fm 23

Page 24: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Operation Cub 200/300/300 HD

3.12 Shutting Down the Machine

Electric shock and cutting injury hazard! At temperatures above 104°F(40°C), electric power is available at the supply blower even with theoperation mode switch in the OFF position. Always remove all powerto the machine before servicing it.

3.12.1 Move the power switch to the Off (“O”) position.Note: The burner will shut down; however, the fan will continue tooperate for approximately two minutes to allow the combustionchamber to cool.

3.12.2 When the blower has shut off automatically, disconnect the powersupply cord.

3.12.3 Disconnect the remote thermostat and re-install the receptacle cover.

WARNING

wcghi_tx000720gb.fm 24

Page 25: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Operation

3.13 Using the Remote Thermostat

See Graphic: wcghi_gr004009In order for the machine to function, the remote thermostat (b) or thereceptacle cover (a) must be installed into the control panel. To use theremote thermostat:

3.13.1 Plug (c) the remote thermostat into the control panel.3.13.2 Set the sensor end within the space to be heated.3.13.3 Adjust the temperature setting with dial (d).

wcghi_tx000720gb.fm 25

Page 26: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Operation Cub 200/300/300 HD

Notes:

wcghi_tx000720gb.fm 26

Page 27: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

4 Maintenance

4.1 Periodic Maintenance Schedule

Prior to first seasonal use

As needed or during regular maintenance

Every 1200 hours

or yearly

Replace the burner nozzle

Replace the fuel filter

Inspect the burner electrodes

Inspect and clean the Cadmium (CAD) cell.

Check the fuel pressure

Clean the fan blades and motor

Clean the interior shell

Inspect the flame head

Inspect all electrical connections

wcghi_tx000721gb.fm 27

Page 28: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.2 Removing and Installing the Burner Assembly

See graphic: wcghi_gr004015Before performing any maintenance on the burner assembly, it mustbe removed from the machine. To remove or install the burnerassembly perform the following procedure:Removal:

4.2.1 Shut down the machine and allow it to cool.

4.2.2 Disconnect the power cord from the power source.

4.2.3 Remove the two bolts (a) and open the access panel.4.2.4 Remove the screw (d) to disconnect the ground wire (c) from the

burner assembly.

4.2.5 Rotate the burner assembly (b) counter-clockwise and remove it fromthe flame head and air tube assembly (e).

4.2.6 Perform the required maintenance. Note: Refer the maintenance procedures in this manual.

4.2.7 Re-install the burner assembly. Refer to the steps below to install theburner assembly.

Installation:

4.2.8 Place the burner assembly into the flame head and air tube assembly(e).

4.2.9 Rotate the burner assembly clockwise to lock it into place.

4.2.10 Install the ground wire (c) using the screw (d).4.2.11 Close the access panel and re-install the two bolts (a) that secure the

panel.

wcghi_tx000721gb.fm 28

Page 29: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

wcghi_tx000721gb.fm 29

Page 30: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.3 Replacing the Burner Nozzle

See Graphic: wcghi_gr004016To replace the burner nozzle, carry out the following procedure:Removal:

4.3.1 Remove the burner. See section Removing and Installing the BurnerAssembly.

4.3.2 Place an adjustable wrench on the large fitting (1) on the nozzle base(3).

4.3.3 Place another adjustable wrench on the nozzle (2).4.3.4 Rotate the nozzle counter-clockwise and remove it from the assembly.

Installation:

4.3.5 Install the new nozzle (2) onto the nozzle base (3).4.3.6 Tighten the nozzle (2) using an adjustable wrench. Rotate the wrench

clockwise.

4.3.7 Re-install the burner assembly. See section Removing and Installingthe Burner Assembly.

wcghi_tx000721gb.fm 30

Page 31: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

4.4 Replacing the Fuel Filter

See Graphic: wcghi_gr004019

Hot surface hazard. The external surface of the fuel filter may be hot.

• Allow the machine to cool before servicing.

• Wear safety gloves.

Hot fluids. The fuel inside the filter canister may be hot.

• Allow the machine to cool before servicing.

• Wear safety glasses.

To replace the fuel filter (b), carry out the following procedure.Removal:

4.4.1 Shut down the machine and allow it to cool.

4.4.2 Remove all power from the machine (unplug).

4.4.3 Remove the screw (a) that secures the cover to the housing.

4.4.4 Remove the filter (b).

Installation:

4.4.1 Install the new filter (b).4.4.2 Inspect the rubber gasket (c) for damage.

4.4.3 Install the cover and the screw (a).

CAUTION

WARNING

wcghi_tx000721gb.fm 31

Page 32: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.5 Inspecting and Aligning the Burner Electrodes

See graphic: wcghi_gr004020To inspect and align the burner electrodes, carry out the followingprocedure.Inspection:

4.5.1 Remove the burner assembly. See section Removing and Installingthe Burner Assembly.

4.5.2 Inspect the electrodes for the following:• Wear. Be sure to inspect the ends of the electrodes for

pitting. Replace any worn electrodes. See section “Replacement or Alignment”.

• Straightness. Replace any bent or broken electrodes. See section “Replacement or Alignment”.

• Corrosion and/or cleanliness. Clean the electrodes with a soft dry cloth or replace if necessary. See section “Replacement or Alignment”.

• Correct alignment. Align the electrodes as shown.Replacement or Alignment:

4.5.3 Loosen the screw (1).4.5.4 Align the electrode as shown or remove if necessary.4.5.5 Install a new electrode if necessary.4.5.6 Tighten the screw (1).4.5.7 Verify the electrodes are correctly aligned.4.5.8 Reinstall the burner. See section Removing and Installing the Burner

Assembly.

wcghi_tx000721gb.fm 32

Page 33: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

4.6 Inspecting and Cleaning the Cadmium (CAD) Cell

See Graphic: wcghi_gr004021To inspect and clean the CAD cell, carry out the following procedure.

4.6.1 Remove the burner assembly. See section Removing and Installingthe Burner Assembly.

4.6.2 Twist and pull out the plastic protective holder (1) off the base of theburner assembly. The CAD cell is inside this plastic holder.

4.6.3 Inspect the CAD cell for the following:• Cleanliness. Be sure the cell is free of debris or soot.

4.6.4 Clean the cell if necessary.NOTICE: Do NOT use solvents or liquids to clean the CAD cell. Use asoft dry cloth to clean the CAD cell.

4.6.5 Reinstall the plastic protective holder (1) onto the base of the burnerassembly.

4.6.6 Reinstall the burner assembly. See section Removing and Installingthe Burner Assembly.

wcghi_tx000721gb.fm 33

Page 34: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.7 Checking and Adjusting the Fuel Pressure

See Graphic: wcghi_gr004025To check the fuel pressure a pressure gauge is needed. To check and/or adjust the fuel pressure, carry out the following procedure:

4.7.1 Shut down the machine and allow it to cool.

4.7.2 Disconnect the power cord from the power source.

4.7.3 Remove the two bolts (a) and open the access panel.4.7.4 Remove the threaded plug (b) from the pressure test port using an

allen wrench. Set the plug in a safe location to be re-installed later.

4.7.5 Install a pressure gauge with adapter in the pressure test port (c). 4.7.6 Start the machine. See section Starting the Machine.

4.7.7 With the machine running, verify the fuel pressure setting. For thecorrect settings, refer to the Technical Data charts in this manual.

4.7.8 Shut down the machine. See section Shutting Down the Machine.

4.7.9 Adjust the fuel pressure if necessary using the adjusting screw (e) andre-check the settings. Repeat steps 6-8 to re-check the settings.

Do not adjust the fuel pressure to a setting outside the safe operationalparameters.

4.7.10 Remove the pressure gauge (d) from the pressure test port (c).4.7.11 Re-install the threaded plug (b) into the pressure test port (c).4.7.12 Close the access panel and re-install the two bolts (a) that secure the

panel.

wcghi_tx000721gb.fm 34

Page 35: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

wcghi_tx000721gb.fm 35

Page 36: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.8 Cleaning the Fan Blades and Motor

See graphic: wcghi_gr004030To clean the fan blades and motor, carry out the following procedure:

4.8.1 Shut down the machine and allow it to cool.

4.8.2 Disconnect the power cord from the power source.

4.8.3 Remove the fan guard. There are four screws that secure the guard.

4.8.4 Remove the six bolts that secure the top portion of the shell.4.8.5 Remove the top shell to access the interior of the machine.

4.8.6 Inspect and, if necessary, clean the motor using compressed air.

4.8.7 Clean the fan blades using a brush.

4.8.8 Re-install the top shell using the six bolts.

4.8.9 Re-install the fan guard.

wcghi_tx000721gb.fm 36

Page 37: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

4.9 Cleaning the Interior Shell

See graphic: wcghi_gr004029To clean the interior shell, carry out the following procedure:

4.9.1 Shut down the machine and allow it to cool.4.9.2 Disconnect the power cord from the power source.4.9.3 Remove the fan guard. There are four screws that secure the guard.4.9.4 Remove the six bolts that secure the top portion of the shell.4.9.5 Remove the top shell to access the interior of the machine.4.9.6 Inspect and, if necessary, clean the interior shell using compressed air.4.9.7 Re-install the top shell using the six bolts.4.9.8 Re-install the fan guard.

wcghi_tx000721gb.fm 37

Page 38: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.10 Inspecting the Flame Head

See Graphic: wcghi_gr004028To inspect the flame head, carry out the following procedure:

4.10.1 Remove the burner assembly. See section Removing and Installingthe Burner Assembly.

4.10.2 Mark the location of the air lock sleeve (c) with a pencil.

4.10.3 Loosen the wing nut (b).4.10.4 Loosen the four screws (a) that secure the flame head (d).4.10.5 Turn the flame head (d) counter-clockwise and remove.

4.10.6 Inspect the flame head (d) for the following:

• Wear. Replace if necessary.

• Cleanliness. Clean the flame head if necessary.

• Thermal stress. Replace if necessary.

4.10.7 Re-install the flame head (d). 4.10.8 Position the air lock sleeve (c) at the marked location.

4.10.9 Tighten the wing nut (b).4.10.10 Tighten the four screws (a).4.10.11 Re-install the burner assembly. See section Removing and Installing

the Burner Assembly.

wcghi_tx000721gb.fm 38

Page 39: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

4.11 Inspecting the Electrical Connections

After disconnecting the power cord, check all electrical connections forthe following:

• Proper connections. Be sure that all connections are complete and tight.

• Corrosion. Clean or replace if necessary.• Damaged wires/connectors. Replace if necessary.• Proper ground.

4.12 Fuel Blend Guide

Fuel Blend Guide

Temperature Range Fuel Blend

15° to 30°F 80% #2 : 20% #1

0° to 15°F 70% #2 : 30% #1

–15° to 0°F 50% #2 : 50% #1

below –15°F 30% #2 : 70% #1

wcghi_tx000721gb.fm 39

Page 40: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.13 Transporting

Cub series Air Heater machines must be supported by use of blocksduring transport. NOTICE: DO NOT strap or chain down the unit withthe foot or wheels in contact with the transporter.• Openings or the entire unit should be covered during transport to

avoid road debris and clutter. • Take care when placing straps on areas which are painted red.

Use corner protectors and never use chains.• Excessive loading on the foot, wheels, and axle will cause

permanent damage• The foot and wheels are for moving by hand and for parking only.• This unit is not designed to be towed with any vehicle.• All venting external to the machine must be removed prior to

transporting. • Only qualified riggers should attempt aerial lifting.

wcghi_tx000721gb.fm 40

Page 41: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

4.14 List of Abbreviations

Amp ampere (unit of electrical current)

asl above sea level

BTU British Thermal Unit

°C Celsius (metric unit of temperature)

°F Fahrenheit (unit of temperature)

ft2 square foot/square feet (measurement of area)

ft.lbs. foot pounds (unit of torque)

gph gallons per hour (unit of liquid flow)

GFI Ground Fault Interrupt(er) (protection device)

Hz Hertz (unit of frequency)

ID inner diameter

in. inch

kg kilogram

kilo-cal kilo-calorie (1000 calories) (metric unit of heat energy)

kPal kilo-Pascals (metric unit of pressure)

kW kilo-Watt (unit of electrical power)

lb. pound

m meter

mm millimeter (1/1000 of a meter)

psig pounds per square inch gauge (unit of pressure)

VAC Volts, Alternating Current

VDC Volts, Direct Current

VFD Variable Frequency Drive

HTF Heat Transfer Fluid

wcghi_tx000721gb.fm 41

Page 42: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.15 Troubleshooting

Note: The following symptoms and remedies are some of the morecommon issues that have arisen during the history of these machines.These do not represent all the possibilities. If you need advancedtroubleshooting assistance, please contact Wacker Neuson ProductSupport.

Symptom Possible Causes Remedy

The burner does not start • The remote thermostat or thermostat plug is not inserted correctly.

• Faulty cable or power supply

• The over temperature limit has tripped

• The burner is in lock-out mode.

• Insert the remote thermostat or thermostat plug.

• Check cable and power supply

• Press the reset button.

The burner starts, the flame does not ignite, the unit locks out

• No fuel• Worn burner nozzle• Faulty electrodes• Cad cell detecting

external light.• Cad cell defective• Burner control defective

• Fill fuel tank• Replace burner nozzle• Replace electrodes• Check the Cad cell

enclosure

The burner starts, flame ignites, but the unit locks out

• Incorrect fuel pressure• Worn burner nozzle• Incorrect air lock setting• Cad cell defective• Burner control defective

• Increase fuel pressure• Replace burner nozzle• Re-adjust air lock setting

The burner ignites but the performance is poor

• Worn burner nozzle• Clogged fuel filter• Air leaks in the fuel lines

• Insufficient oil pressure

• Replace burner nozzle• Replace the fuel filter• Inspect the lines for

leaks; replace if necessary

Black smoke from vent pipe • Insufficient combustion air

• Insufficient ventilation air

• Remove any obstructions from the air inlet and outlet areas.

The machine stops due to pressure switch fault

• Overheat condition• Faulty pressure switch

• Contact Wacker Neuson Product Support

wcghi_tx000721gb.fm 42

Page 43: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

Notes:

wcghi_tx000721gb.fm 43

Page 44: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

4.16 Cub 200/300 Wiring Schematic

4.17 Cub 300 HD Wiring Schematic

wcghi_tx000721gb.fm 44

Page 45: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Maintenance

4.18 Schematic Legend

Ref. Description Ref. Description

a Fuel solenoid valve i Pressure switch

b Photo cell j Push button reset light

c Fuse k Heated filter

d ON-OFF switch l Relay

e Motor m Temperature limit control

f Power light n Capacitor

g Remote thermostat o Air temperature switch

h Transformer p Nozzle preheater

wcghi_tx000721gb.fm 45

Page 46: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Maintenance Cub 200/300/300 HD

wcghi_tx000721gb.fm 46

Page 47: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Cub 200/300/300 HD Technical Data

5 Technical Data

5.1 Machine Technical Data

Item NumberModel

06202040620262Cub 200

0620233Cub 300

0620253Cub 300 HD

Units

Heat input BTU/hr 180,000 289,000 289,000

Heat output BTU/hr 147,000 232,000 232,000

Air flow cfm 1300 2600 2600

Fuel consumption L (gal)/hr 4.85 (1.28) 7.72 (2.04) 7.72 (2.04)

Fuel nozzle size gal/hr-deg 1.00-60 1.5-80 1.35-80

Efficiency % 81.5 80 80

Noise level at 2 m dB (A) 73 71 73.9 (at 3 m)

Power requirement VAC/Hz 115/60 115/60 115/60

Electrical current Ampere 7 12 14

Weight (no fuel) kg (lb) 79.4 (175) 116.1 (256) 264(583)

Height cm (in.) 78.7 (31) 116.8 (46) 130.8(51.5)

Length cm (in.) 139.7 (55) 172.7 (68) 228.3(89.9)

Width cm (in.) 61 (24) 69.9 (27.5) 97.5(38.4)

Flue diameter cm (in.) 15.2 (6) 15.2 (6) 15.2 (6)

Fuel tank capacity L (gal) 100 (26.42) 138.9 (36.7) 232.8(61.5)

Fuel pressure psi 175 175 218

Air lock setting number 2 3 5

wcghi_td000213gb.fm 47

Page 48: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Technical Data Cub 200/300/300 HD

wcghi_td000213gb.fm 48

Page 49: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm
Page 50: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Wacker Neuson SE · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02-0 · Fax: +49 - (0)89-3 54 02-390Wacker Neuson Corporation · P.O. Box 9007 · Menomonee Falls, WI 53052-9007 · Tel. : (262) 255-0500 · Fax: (262) 255-0550 · Tel. : (800) 770-0957Wacker Neuson Limited - Room 1701–03 & 1717–20, 17/F. Tower 1, Grand Century Place, 193 Prince Edward Road West, Mongkok, Kowloon, Hongkong.Tel: (852) 3605 5360, Fax: (852) 2758 0032

Page 51: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

www.wackerneuson.com

0620253 105

05.2010

Portable Indirect Air HeatersFahrbare Kaminheizgeräte

Calentadores de aire indirectos portátilesRéchauffeurs indirects d'air (portatifs)

CUB 300HD

Parts BookErsatzteileLista de RepuestosListe de Pièces de Rechange

Page 52: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm
Page 53: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

A nameplate listing the Model Number, Item Number, Revision, and Serial Number isattached to each unit. Please record the information found on this plate so it will be availableshould the nameplate become lost or damaged. When ordering parts or requesting serviceinformation, you will always be asked to specify the model, item number, revision number,and serial number of the unit.

Ein Typenschild mit Typ, Artikelnummer, Version und Maschinen-Nummer ist an jedemGerät angebracht. Die Daten von diesem Schild bitte notieren, damit sie auch bei Verlustoder Beschädigung des Schildes noch vorhanden sind. Der Typ, die Artikel-Nummer, dieVersions- Nummer und die Maschinen-Nummer sind bei der Ersatzteilbestellung oderNachfragen bezüglich Service-Informationen stets erforderlich.

Una placa de identificación con el modelo, número de referencia, nivel de revisión y númerode serie ha sido añadida en cada máquina. Favor de anotar los datos en la placa en casode que la placa de identificación sea destruida o perdida. En todos los pedidos pararepuestos necesita siempre el modelo, el número de referencia, el nivel de revisión y elnúmero de serie de la máquina en cuestión.

Une plaque signalétique mentionnant le modèle, le numéro de référence, le niveau derevision et le numéro de série est fixée sur chaque machine. Veuillez noter les informationsrelevées sur cette plaque de façon à ce qu’elles soient toujours disponibles si la plaquesignalétique venait à être perdue ou endommagée. Lorsq ue vous commandez des piècesdétachées ou vous sollicitez des informations après-vente, on vous demandera toujours depréciser le modèle, le numéro de référence, le niveau de revision et le numéro de série dela machine.

My machine’s numbers are / Die Nummern meines Gerätes sind /Los números de mi máquina son / Les numéros de ma machine son :

CUB 300HD NameplateTypenschild

Plaque signalétiquePlaca de Identificación

0620253 - 105 3

Page 54: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Part Numbers appearing in boldface type are recommended spare parts. This means thatthese parts are subject to wear under normal operating conditions and may require periodicservice or replacement. It is recommended that these items be stocked to meet theexpected service requirements of this model. Actual stocking quantities of these and otherparts used in more extensive repairs will depend on the service practices of each customer.

Bei den in den Ersatzteillisten fettgedruckten Nummern handelt es sich um empfohleneErsatzteile. Dies bedeutet, daß diese Teile bei normalen Anwendungsbedingungennatürlicher Abnutzung ausgesetzt sind und gelegentlich ersetzt oder überarbeitet werdenmüssen. Es wird geraten, diese Teile auf Lager bereit zu haben, um für Service-Arbeiten andiesem Gerät vorbereitet zu sein. Lagerbestände für diese und andere Teile, welche fürausgiebigere Reparaturarbeiten benötigt werden, können je nach Service-Gewohnheitender einzelnen Kunden variieren.

Los números de partes en negritas en las Listas Ilustradas de Partes son los repuestosrecomendados, ésto quiere decir que estas partes se desgastarán bajo circunstancias defuncionamiento normales y pueden requerir servicio periódico o su reemplazo. Serecomienda que el cliente mantenga un abastecimiento adecuado de estas partes parapoder satisfacer la demanda requerida por el servicio a la máquina. La cantidad derepuestos que el cliente necesitará para reparaciones dependerá de la póliza de servicio decada cliente.

Les numéros de pièces imprimés en caractères gras dans les Listes des Pièces Détachéesde ce manuel sont les pièces détachées recommandées par la Wacker. Cela veut dire queces pièces sont sujettes à usure dans des conditions de travail normales et peuventnécessiter de l’entretien ou leur remplacement. Nous recommandons que vous disposezd’un stock de ces pièces pour pouvoir satisfaire la demande d’entretien de cette machine.Le client doit decider lui-même de la quantité exacte de pièces de rechange qu’il disposeradans ses stocks.

Part Numbers - BoldfaceFettgedruckte Artikelnummern CUB 300HD

Números de partes en negritasNuméros de pièce - en caractères gras

4 0620253 - 105

Page 55: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

HeaterHeizungCalentadorRéchauffeur

6

Frame/ComponentsRahmen/BestandteileChasis/ComponentesChâssis/Composants

12

LabelsAufkleberCalcomaniasAutocollants

16

CUB 300HD Table of ContentsInhaltsverzeichnis

IndiceTable des matières

0620253 - 105 5

Page 56: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

HeaterHeizung CUB 300HD

CalentadorRéchauffeur

6 0620253 - 105

Page 57: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Ref.Pos.

Part No.Artikel Nr.

Qty.St.

DescriptionBeschreibung

DescripciónDescription

Measurem./Abm.

Torque/Drehm.

Norm

SealantSchmierstoff

1 0172597 1 FanGebläserad

VentiladorVentilateur

2 0172598 1 Motor-fanMotor, Lüfter

Motor-ventiladorMoteur - ventilateur

3 0172092 1 Adapter fanAdapter, Lüfter

Ventilador adaptadorAdaptateur, ventilateur

4 0172599 1 Capacitor-fanKondensator, Lüfter

Condensador-ventiladorCondensateur - ventilateur

5 0172093 1 Solenoid coilSolenoidwindung

Bobina del solenoideBobine du solénoïde

6 0172094 2 Cable-fuel pumpKabel, Kraftstoffpumpe

Cable-bomba de combustibleCâble - pompe à carburant

7 0172095 1 Hose-fuelKraftstoffschlauch

Manguera-combustibleFlexible - carburant

8 0172096 1 Fitting-fuel DVerschraubung, Kraftstoff D

Unión-combustible DRaccord - carburant D

9 0172600 1 Pump-fuelKraftstoffpumpe

Bomba-combustiblePompe - carburant

10 0172097 2 WasherScheibe

ArandelaRondelle

11 0172098 3 Fitting-fuel BVerschraubung, Kraftstoff B

Unión-combustible BRaccord - carburant B

12 0172099 5 Fitting-fuel AVerschraubung, Kraftstoff A

Unión-combustible ARaccord - carburant A

13 0172100 2 Fitting-fuel CVerschraubung, Kraftstoff C

Unión-combustible CRaccord - carburant C

14 0172601 2 Hose-back flowSchlauch, Rückfluss

Manguera-retroflujoFlexible - retour

15 0172102 2 Hose-return fuelSchlauch, Rückleitung, Kraftstoff

Manguera-combustible de retornoFlexible - retour carburant

16 0170280 1 Sensor-flameFlammensensor

Sensor-llamaCapteur - flamme

17 0172103 2 Cable-electrodeKabelelektrode

Cable-electrodoCâble - électrode

18 0180719 1 Head-flameVibrationsflasche, Flamme

Cabezal-llamaTête - flamme

20 0170282 2 ElectrodeElektrode

ElectrodoÉlectrode

21 0172105 1 Cover-electric panelAbdeckung, Schaltfeld

Tapa-panel eléctricoCouvercle - tableau électrique

22 0170283 1 TransformerTransformator

TransformadorTransformateur

23 0170284 1 LampLampe

LámparaVoyant

24 0170285 1 Switch, on/offSchalter, ein/aus

Interruptor, enc./apag.Interrupteur, marche/arrêt

25 0172107 1 Cable-powerKabel, Strom

Cable-alimentaciónCâble - alimentation

26 0172603 1 FuseSicherung

FusibleFusible

CUB 300HD HeaterHeizung

CalentadorRéchauffeur

0620253 - 105 7

Page 58: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

HeaterHeizung CUB 300HD

CalentadorRéchauffeur

8 0620253 - 105

Page 59: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Ref.Pos.

Part No.Artikel Nr.

Qty.St.

DescriptionBeschreibung

DescripciónDescription

Measurem./Abm.

Torque/Drehm.

Norm

SealantSchmierstoff

27 0170287 1 Reset-pushbuttonRückstellungsdrucktaste

Restablecimiento-botónRéinitialisation - bouton - poussoir

28 0172109 1 Plug-thermostatStecker, Temperaturregler

Tapón-termostatoFiche - thermostat

29 0170313 1 Thermostat socketTemperaturregler, Buchse

Toma para el termostatoThermostat, douille

30 0176675 1 HousingGehäuse

CajaCarter

31 0172112 1 Control panelSchalttafel

Tablero de mandoTableau de commande

32 0176676 1 SpacerAbstandsstück

EspaciadorEntretoise

33 0170288 1 Burner controlBrennerbetätigung

Control del quemadorCommande de brûleur

36 0176678 1 Suction hoseSaugschlauch

Manguera de succiónTuyau de succion

37 0172114 1 Fitting-fuel EVerschraubung, Kraftstoff E

Unión-combustible ERaccord - carburant E

39 0172115 1 Nut-fuel lineMutter, Kraftstoffleitung

Tuerca-línea de combustibleÉcrou - conduite de carburant

40 0172116 1 Bracket-filterHalterung, Filter

Ménsula-filtroSupport - filtre

41 0172117 1 Fitting-fuel FVerschraubung, Kraftstoff F

Unión-combustible FRaccord - carburant F

42 0176682 1 Filter-oil, heatedÖlfilter, erwärmt

Filtro-aceite, calienteFiltre - huile, chauffée

48 0172123 1 Fitting-fuel suctionVerschraubung, Kraftstoffansaugung

Unión-succión de combustibleRaccord - aspiration carburant

50 0172605 1 Guard-fanSchutz, Lüfter

Protector-ventiladorProtection - ventilateur

51 0172606 1 Rim-fanRand, Lüfter

Aro-ventiladorCouronne - ventilateur

52 0172607 1 Cover-inspectionAbdeckung, Inspektion

Tapa-inspecciónCouvercle - inspection

53 0176679 1 Panel-topPanel, oben

Panel-superiorPanneau - haut

55 0172129 2 GrommetTülle

OjalPasse-fil

56 0172130 2 GrommetTülle

OjalPasse-fil

65 0172137 1 Cover-air, burnerAbdeckung, Luft, Brenner

Tapa-aire, quemadorCouvercle - air, brûleur

66 0172612 1 Head-flameVibrationsflasche, Flamme

Cabezal-llamaTête - flamme

67 0172613 1 Cylinder-combustionZylinder, Verbrennung

Cilindro-combustiónCylindre - combustion

68 0172614 1 Cover-heatAbdeckung, Heizung

Tapa-calorCouvercle - chaleur

69 0176680 1 Duct adapter kitLuftleitblechadaptersatz

Juego adaptador del conductoJeu d?adaptateur de conduit

CUB 300HD HeaterHeizung

CalentadorRéchauffeur

0620253 - 105 9

Page 60: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

HeaterHeizung CUB 300HD

CalentadorRéchauffeur

10 0620253 - 105

Page 61: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Ref.Pos.

Part No.Artikel Nr.

Qty.St.

DescriptionBeschreibung

DescripciónDescription

Measurem./Abm.

Torque/Drehm.

Norm

SealantSchmierstoff

70 0172140 1 Stack-flueSchacht, Luftklappe

Tubo-cañónCheminée - conduit

71 0172141 6 Clip-coverKlemme, Abdeckung

Sujetador-tapaCouvre - attache

72 0172616 1 Panel-bottomBoden-Panel

Panel inferiorTableau - fond

73 0176681 1 ThermostatTemperaturregler

TermóstatoThermostat

74 0180715 1 Pressure SwitchDruckschalter

Interruptor de PresiónInterrupteur à Pression

75 0172143 1 Bracket-air pressure gaugeHalterung, Luftdruckmesser

Ménsula-indicador de presión de aireSupport - manomètre d'air

77 0172145 1 Fitting-air hoseVerschraubung, Luftschlauch

Unión-manguera de aireRaccord - flexible d'air

80 0172118 1 Cover-fuel filterAbdeckung, Kraftstofffilter

Tapa-filtro de combustibleCouvercle - filtre à carburant

82 0170290 1 Filter cartridgeFilterpatrone

Cartucho del filtroCartouche de filtre

83 0180717 1 Heating elementHeizelement

Elemento de calefacciónÉlément chauffant

200W

84 0172122 1 Casing-fuel filterUmhüllung, Kraftstofffilter

Envoltura-filtro de combustibleGaine - filtre à carburant

85 0172108 1 Cover-reset buttonAbdeckung, Rückstelltaste

Tapa-botón de restablecimientoCouvercle - bouton de réinitialisation

86 0176683 1 Gasket KitDichtungssatz

Juego de juntasJeu de joints

91 0180716 1 CoverDeckel

TapaCouvercle

92 0180718 1 ThermostatTemperaturregler

TermóstatoThermostat

93 0172649 1 Adapter-fuelAdapter, Kraftstoff

Adaptador-combustibleAdaptateur - combustible

CUB 300HD HeaterHeizung

CalentadorRéchauffeur

0620253 - 105 11

Page 62: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Frame/ComponentsRahmen/Bestandteile CUB 300HD

Chasis/ComponentesChâssis/Composants

12 0620253 - 105

Page 63: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Ref.Pos.

Part No.Artikel Nr.

Qty.St.

DescriptionBeschreibung

DescripciónDescription

Measurem./Abm.

Torque/Drehm.

Norm

SealantSchmierstoff

1 0173663 1 Upper frameOberer Rahmen

Chasis superiorChâssis supérieur

2 0173665 1 Fuel tankKraftstofftank

Depósito de combustibleRéservoir de carburant

3 0173671 1 Lifting bracketHebebügel

Ménsula alzadoraSupport de relèvement

4 0173664 1 Lower frameUnterer Rahmen

Chasis inferiorChâssis inférieur

5 0173879 1 Lifting bail handleTragegriff

Manija de Agarradero de izarPoignée de relèvement

7 0173927 2 Mounting bracketKonsole

MénsulaSupport

9 0177335 1 Fuel tank bracketKraftstofftankkonsole

Ménsula de tanque de combustibleSupport de réservoir de carburant

200 0173670 1 Heater coreHeizung, Wellenseele

Núcleo del calentadorRéchauffeur, Âme

201 0177156 2 WheelRad

RuedaRoue

16,3 OD, 760lb

202 0170453 1 Gauge-fuelKraftstoffanzeiger

Indicador-combustibleJauge - carburant S9

203 0168154 1 PlugStopfen

TapónBouchon

3/4in NPT

S9

204 0173890 1 Fuel tank capTankverschluß

Tapa del tanqueChapeau de réservoir

2,50in

205 0173998 2 CapKappe

TapaCapuchon

207 0168611 2 ClipClip

ClipClip

1/16in

500 0010374 42 Flat washerScheibe

Arandela elásticaRondelle de ressort

B8,4

501 0011457 22 Hex head screwSechskantschraube

TornilloVis à tête hexagonale

M8 x 25

20Nm/14ft.lbs

502 0033198 54 Lock washerFederring

FederringRondelle de ressort

B8

503 0010882 24 Hex nutSechskantmutter

Tuerca hexagonalÉcrou six-pans

M8

504 0010373 5 Fender washerUnterlegscheibe

ArandelaRondelle

B6,4

505 0173995 4 BoltBolzen

PernoBoulon

M8 x 45

506 0011470 2 Hexagonal head cap screwSechskantschraube

Tornillo hexagonalBoulon à tête hexagonale

M6 x 20

10Nm/7ft.lbs

507 0173987 4 Lock washerFederring

FederringRondelle de ressort

No.6

508 0173988 2 Hexagon nutSechskantmutter

Tuerca hexagonalÉcrou hexagonal

M6

510 0025661 4 Cotter pinSicherungssplint

Clavija hendidaGoupille fendue

1/8 x 1-3/4in

511 0025641 4 Flat steel washerScheibe

ArandelaRondelle

1in

CUB 300HD Frame/ComponentsRahmen/BestandteileChasis/ComponentesChâssis/Composants

0620253 - 105 13

Page 64: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Frame/ComponentsRahmen/Bestandteile CUB 300HD

Chasis/ComponentesChâssis/Composants

14 0620253 - 105

Page 65: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Ref.Pos.

Part No.Artikel Nr.

Qty.St.

DescriptionBeschreibung

DescripciónDescription

Measurem./Abm.

Torque/Drehm.

Norm

SealantSchmierstoff

512 0167806 2 Fender washerUnterlegscheibe

ArandelaRondelle

1/4 x 3/4in

513 0028404 2 Hexagonal flange head screwSechskantflanschschraube

Tornillo hexagonal de bridaVis hexagonale de bride

M8 x 20

20Nm/14ft.lbs

514 0178277 1 WasherScheibe

ArandelaRondelle

24mm ID

S9

515 0179112 1 ClampSchelle

AbrazaderaAgrafe

3/8in ID

600 0177336 1 Ground wireErdungsdraht

Alambre a tierraFil de masse

801 0181250 1 NutMutter

TuercaÉcrou

802 0183685 1 GasketDichtung

JuntaJoint

CUB 300HD Frame/ComponentsRahmen/BestandteileChasis/ComponentesChâssis/Composants

0620253 - 105 15

Page 66: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

LabelsAufkleber CUB 300HD

CalcomaniasAutocollants

16 0620253 - 105

Page 67: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Ref.Pos.

Part No.Artikel Nr.

Qty.St.

DescriptionBeschreibung

DescripciónDescription

Measurem./Abm.

Torque/Drehm.

Norm

SealantSchmierstoff

1 0176654 1 Label -logoAufkleber, Logo

Calcomanía -logotipoAutocollant - logo

2 0176655 1 Label-warningAufkleber-Warnung

Calcomania-AdvertenciaAutocollant-Avertissement

3 0176656 1 Label-instruction plateAnweisungsschild

Placa-instruccionesPlaque d'instructions

4 0176657 1 Label-hazardous voltageAufkleber, gefährliche Spannung

Calcomanía-voltaje peligrosoAutocollant - tension dangereuse

5 0176658 1 Label-dangerAufkleber, Gefahr

Calcomanía, peligroAutocollant-danger

7 0176660 1 Label-diesel fuel selectionAufkleber, Dieselkraftstoffauswahl

Calcomanía-selección de combustibledieselAutocollant - choix du carburant diesel

8 0176661 1 Label-dangerAufkleber, Gefahr

Calcomanía, peligroAutocollant-danger

401 0177155 1 Label-rating plateAufkleber, Typenschild

Calcomanía-placa de clasificaciónAutocollant - plaque signalétique

402 0177368 2 Label-weightAufkleber, Gewicht

Calcomanía-PesoAutocollant - Poids

403 0177369 4 Label-tie down markerAufkleber, Festzurrmarkierung

Calcomanía-marcador de atadurasAutocollant - marqueur d'arrimage

404 0177370 3 Label-warningAufkleber-Warnung

Calcomania-AdvertenciaAutocollant-Avertissement

405 0177371 1 Label-warningAufkleber-Warnung

Calcomania-AdvertenciaAutocollant-Avertissement

406 0168897 2 Label-center of gravityAufkleber, Schwerpunkt

Calcomanía-centro de gravedadAutocollant - centre de gravité

407 0168893 1 Label-hot surfaceAufkleber-heisse Oberfläche

Calcomania-superficie calienteAutocollant-surface brûlante

408 0172640 2 Caution labelAufkleber-Vorsicht

Calcomania-PrecauciónAutocollant-Précaution

409 0172224 1 Diesel fuel labelAufkleber, Dieselkraftstoff

Calcomanía, combustible DieselAutocollant de carburant diesel

3 x 6

CUB 300HD LabelsAufkleber

CalcomaniasAutocollants

0620253 - 105 17

Page 68: Indirect-fired Air Heaters Cub 200/300/300 HD 300 HD...Indirect-fired Air Heaters Cub 200/300/300 HD OPERATOR’S MANUAL 0170893en 006 0809 0170893 EN Foreword wcghi_tx000001gb diesel.fm

Wacker Neuson SE - Preußenstraße 41 - 80809 München - Tel.: +49-(0)89-35402-0 - Fax: +49-(0)89-35402-390Wacker Neuson Corporation - P. O. Box 9007 - Menomonee Falls, WI 53052-9007 - Tel.: (262)-255-0500 - Fax: (262)-255-0550Wacker Neuson Ltd. - Tower 1, Grand Century Place - 193 Prince Edward Road West - Mongkok, Kowloon - Hong Kong, VR China - Tel: +852-3605 5360, Fax: +852-2406 6021