indiana center for coal technology research carbon … · 2016-12-08 · indiana center for coal...
TRANSCRIPT
INDIANA CENTER FOR
COAL TECHNOLOGY RESEARCH
Carbon Capture & Sequestration
HTC Purenergy
September 10, 2009
HTC… “Leaders in CO2 Capture & Management ”
3
Technical Services Centre is based at U of R, International Test Centre for CO2 Capture
Commercial Offices located in Regina Canada, Vermont USA,Sydney Australia, and Beijing China
Traded on the Toronto Venture Exchange. Symbol: HTC
Successful aggregation, development, integration and commercialization of world leading carbon clear energy technologies.
HTC Profile“Energy Technology Company founded to seize opportunities in Carbon
Capture , Carbon Management and Carbon Mitigation”
HTC… “Leaders in CO2 Capture & Management ”
Strategy
License or own CO2 capture plants,
retrofitted to coal and gas fired power
plants
Will finance, construct and manage based
on long-term contracted off-taker of CO2
Preference is to own the plant (as a speed-
to-market tool)
Initially license to establish a beachhead
5
CO2 Capture CO2 EOR CO2 Storage
1.Technology Licensor 1.Oil Field Analysis/ 1. Geological Profiling
Simulation
2. OEM Supplier 2. Oil Field Economics/ 2. Risk Assessment
project validation
3. Engineering Services 3. CO2 Compression 3. CO2 Audit & Monitor
& Injection
4. Carbon Credit Validation
Core Business Activities
Confidential & Proprietary Information
HTC… “Leaders in CO2 Capture & Management ”
6
HTC’s Collaborative Partners
Confidential & Proprietary Information
HTC… “Leaders in CO2 Capture & Management ”
Licensing Partner:
Bechtel Overseas Corporation
Confidential & Proprietary Information
•World’s largest power
plant EPC
• 110 year history - 19,000
projects
• Experience with CO2 capture
systems
• Procurement capabilities from
many countries world-wide
Headquartered in Crawley,
England, with main facilities in
Renfrew, Scotland, and Branch
offices throughout the UK
FY 2007 annual order book
forecast £623 million
(US$1250m approx)
Employees 4,500 worldwide
Largest power plant boiler
OEM/EPC in the world
20 locations world-wide to
service power industry
Owned by Korean based
Doosan Heavy Industries
(40,000 employees),
committed to expanding the
technology globally
Crawley
Licensing Partners:
Doosan Babcock Energy Limited
Renfrew
Page 9
Doosan Mecatec Experience Record -
Column/TowerClient PJ Name Service Name Material Size Weight
(TH'k x ID x Length) (Ton)
Foster Wheeler UK Yanbu Wash Tower A516-70+304L 55+3~61+3 x 8,100 x 86,500 1,500
Reliance (India) Jerp Main Column A387-22+410S 54+3~61+3 x 11,000 x 51,400 912
Reliance (India) Jerp Crude Column A516-70+SS347 54+3x9,600 x 62,700 993
Reliance (India) Jerp Vacuum Column A516-70+410S 20+3~46+3 x 12,500 x 27,300 649
Reliance (India) Jerp C3 Splitter A516-70 68 x 7,500 x 97,000 1,304
JGC (Japan) Rabigh Main Fractionator A387-11+304L 72+3 x 10,200 x 52,400 1,013
Chiyoda (japan) CSPC N. LOP Quench T/W A516-70 20/27/28 X 10,000 x 51,800 790
Bechtel (USA) Equiva CDHS Column A516-70+410S 51.4+2.6 x 5,792 x 43,892 710
Technip (France) 10th Olefin C2 Splitter A537+CL2 40/41 x 6,000 x 88,920 644
Chiyoda (japan) QGX II Deetanizer A240-304L 94/112/71 x 6,000 x 46,785 635
YAEG PJ(2006)
61+3mm(Th’k) X 8,100mm(ID) X 86,500mm(L)
1,500Ton , SA516-70 +SS304L WASH TOWER
JAMNAGAR COMPLEX PJ(2005)
68mm(Th’k) X 7.5m(ID) X 97m(L) 13.5m(Skirt ID),
1,304Ton,SA516-70C3 Splitter
- 9m(ID) x 57m(L)
- NET W’T : 821TON
- GROSS W’T : 920TON
10
Doosan Changwon Plant
⊙ Seoul
◎
Changwon
Total Area : 4,425,570 ㎡
Floor Space : 554,988 ㎡
• Largest energy infrastructure manufacturing facility in the world.
• Similar Plant under construction in Vietnam.
• Manufacturing of Integrated boilers and CCS systems.
HTC… “Leaders in CO2 Capture & Management ”
Confidential & Proprietary Information
11
World Distribution of Doosan Babcock Plants
Total MW since 1995
Subcritical 12,525MW
Supercritical 29,400MW
Total 41,925MW
Total MW
Sub-critical 107,157
Supercritical 44,601
Total Fossil Fired 151,758
Nuclear 6,054
Grand Total 157,812
Confidential & Proprietary Information
12
Carbon Capture & Storage, May 2009
HTC PurenergyHTC… “Leaders in CO2 Capture & Management ”
International Test Centre for CO2 Capture
World Leader in CO2 Capture and Enhanced Oil Recovery
Home of - HTC’s technical centre
Greenhouse Gas Technology Centre
HTC… “Leaders in CO2 Capture & Management ”
ITC - Natural Gas flue gas capture Centre
HTC… “Leaders in CO2 Capture & Management ”
Coal flue gas demonstration - Test Facilities –
Boundary Dam – Estevan, Saskatchewan
HTC… “Leaders in CO2 Capture & Management ”
Weyburn Field
CANADA
U.S.A.
ALBERTA
MANITOBA
MONTANA
WYOMINGSOUTH DAKOTA
NORTH DAKOTA
EDMONTON
SASKATOON
PRINCE
ALBERT
WINNIPEG
BRANDON
REGINA
HELENA
BISMARCK
PIERRE
CALGARY
Williston Sedimentary Basin
HUDSONBAY
WEYBURN
• SASKATCHEWAN
Field Size: 70 sq. miles OOIP: 1.4 billion bbls
Oil Recovered: 370 million bbls CO2 IR: 130 million bbls
HTC… “Leaders in CO2 Capture & Management ”
Dakota Gasification CompanyLignite to natural gas
• Dakota Gasification
Company
• 250 MMscfd CO2 by-
product of coal (lignite)
gasification
• 95 MMscfd (5000
tonnes/day) contracted
and injected at Weyburn
• CO2 purity 95%
• EnCana currently injects
120 MMscfd (i.e. 21%
recycle)
Regina
Estevan
Bismarck
North Dakota
Montana
Manitoba
Saskatchewan
Weyburn
Beulah
Weyburn Field CO2 Source
HTC… “Leaders in CO2 Capture & Management ”
HTC’s CCS FEED Engine™
Rrij
Llij
Ssij
Eeij
Uij
casij
cfeij Yijp
cdqij
cbrij
Ee = ij Eeij Xp = ij Xijp
Rr = ij Rrij
L = l Ll
E = e Ee
Ll = ij Llij
Tp = ij Tpij
Fp
Cij
Xijp
Xq or Tqij
Fp1
Fp2
Tpij
Ss = ij Ssij
HTC’s proprietary “process integration & Front End Engineering Design (FEED) Engine” that delivers
customized precision design solutions for optimized carbon capture systems (CCS)
Geological ModelGeological model data sources
3D-seismic
Core data
Log data
Well survey data
Geological model sizeGrid numbers 30 X 37 X 45
Grid size 50 X 50 X 6 ft.
Active grid blocks 15,763
PVT modelAn 8-component PR EOS
Tuned based on PVT studies
Recent PVT study for MMP (2886 psi and 2407 psi)
Global Energy Presentation, March 8, 2007
Monitoring CO2
Techniques
4D, 3C surface seismic
4D, 9C surface seismic
3D, 3C vertical seismic profile (VSP)
Cross-well seismic (H and V wells)
Passive micro-seismic
Geochemical sampling analysis
Tracer injection monitoring
Conventional produced fluid analysis
Production measurement and mixing
facility
MMV TECHNOLOGY
Kårstø, Norway
Capture of 85% of the total flue gas from the 420 MW power plant with strict performance guarantees.
The required operating range of the CO2 capture plant is between 60 – 100% of the total plant flue gas capacity.
It is required to evaluate the effects of varying the CO2 capture rate between 80 and 90%.
The captured CO2 is liquefied for pump out for EOR applications.
Qualified to compete for FEED study and EPCI Contract
CO2 Capture Study
for:
Integration with the Power Plant &
Modules Delivery to the Site
UK NORTH SEA
What is Marine CNG?
Compressed Natural Gas
Pressurized Gas
120 – 275 bar
-30°C to 40°C
300:1 Energy Density
Heavier Containment
Less Cargo per Voyage
No Liquefaction & Re-gas
Liquefied Natural Gas
Cryogenic Liquid
0.25 bar
-160 °C
600:1 Energy density
Lighter Containment
More Cargo per Voyage
Liquefaction & Re-gas
Adding CO2 Capacity
Backhauling CO2
Post de-hydration, current metallurgy is
compatible
Might require CO2 shore-based buffer storage
(Possible) Dedicated carbon dioxide storage
compartment
Vessels already fitted with compression
Transport and injection is in dense phase
• Environmental Energy Technology Company
• Building a portfolio of IGCC and Synthetic Gas Facilities
• Develop, Own & Operate Strategy
• Gasification Technology and Advanced Fuel Technology expertise
• Technology Centers of Excellence --Wabash(US) & Westfield(Scotland)
• CO-Owner of Wabash River Energy: World’s cleanest coal / pet coke based IGCC power plant
• Currently building the only permitted IGCC Power plant in the US
HTC… “Leaders in CO2 Capture & Management ”
30Confidential & Proprietary Information
Ohio, Oil and Gas Map
Lima Facility
HTC… “Leaders in CO2 Capture & Management ”
•EOR production of
497mm bbls within 100
miles of Lima.
•30% equity interest in
Carbon Management
Technologies.
Natural gas wells
Oil wells
CO2 Pipeline
Michigan Producing Wells
Masdar – Carbon Capture
Project
EMAL AND TAPCO PROJECTS – 2009
Enel - Porto Tolle, Italy
4,500 CO2 tpd coal plant FEED
Vattenfall – Denmark
Project EOR Fields in China
Figure 1 Oilfields, locations, and potential CO2 sources in China.
Oilfield: DaQing
Company: PetroChina
Distance from Beijing: 800 km
CO2 EOR fields: 2 (underway)
CO2 source: PetroChemical Plant
Oilfield: JiLin
Company: PetrChina
Distance from Beijing: 600 km
CO2 EOR field: 1 (underway)
CO2 source: 1 reservoir
Oilfield: ChangQing
Company: PetroChina
Distance from Beijing: 800 km
CO2 EOR field: N/A
CO2 source: N/A
Dagang Huashi Power Plant CCS and EOR Engineering Study
Location : 165km SE of Beijing
Administratively Tianjin is one of the four municipalities that have province – level status, reporting directly to the central government. Its urban area is the third largest in China,
ranked only after Beijing and Shanghai.
Population : 11,519,000
• 2200 MW Coal Fired Power Station
• Loy Yang Power
• Brown Coal plant: 60,000 tpd
• Supplies 1/3 Victoria’s Power
• 17mtpa CO2 emissions
• 1 of 4 majors within in 50km Hazelwood , Yallourn
• LaTrobe total emissions 50mtpa
• Sequestration evaluationcompleted and costed.
• Feasibility study agreed.
Australia - AGL Project SiteHTC… “Leaders in CO2 Capture & Management ”
European CO2 Test Centre Mongstad (TCM)Oil refinery cat cracker flue gas and gas turbine exhaust gas
Absorption Column, 14 ft-6 in ID x high 119 ft
Engagement to Reduce Steam Consumption and
to Enhance CO2 Production
Plant Design Capacity 800 TPD, two trains
CCS Purenergy 1000
SASKATCHEWAN-MONTANA
CCS PROJECT
Saskatchewan CCS Project led by University of Regina
Big Sky Regional Carbon Sequestration Partnership
Timely and meaningfully-sized CCS Project
1,000 t/d CO2 capture plant
Coal-fired power plant southern Saskatchewan
60 mile pipeline across border into USA
Plant commissioning by end of 2010
2/3 years injecting CO2 into saline aquifer with MMV
Switch CO2 supply to oil field for EOR after sequestration
Funding 1/2 Canada, 1/2 US, plus industry participation
International Performance Assessment Centre-CO2 (IPAC-CO2)
Project Location
Two possible SaskPower coal-fired plants are being considered as sites for
the capture/reference plant in southern Saskatchewan: Coronach or
Estevan/Shand lignite-fired units.
Coronach, SK
Estevan, SK
Wolfpoint, MT
The underground
pipeline attached to
the capture unit at
an existing
SaskPower plant will
deliver CO2 from
Saskatchewan to a
geological storage
site in northeastern
Montana on the
northwestern flank of
the Williston Basin.
What is IPAC-CO2? • An independent,
international network that provides and advances global expertise to benchmark, evaluate and advise on the risks and performance of geological storage of carbon dioxide.
+ 2000m TVD
Reaction Chamber
+ 30m
+ 450m
Coal >2m to > 5mthickness
NOT TO SCALE
InjectionWell
Copyright BCG Energy 2009
ProductionWell
6
synthesis gas CO + H2oxygen & steam
Well Paths
13
Firth of Forth Area UK
Edinburgh
London
Copyright BCG Energy 2009
Edinburgh
FIRTH OF FORTH, SCOTLANDPotential CO2 Source to Sink
Coal
Raw
Syngas
Gas
Cleanup
Hydrogen Power
Generation
Gas Turbine Power
Generation or Gas sales
UCG Firth of ForthHow it works…
CO +
H2
CCS
2nd Grid
3rd Chemicals
1st Grid
H2S CO2
AFC
CO Carbon Monoxide
CCS Carbon Capture and Storage
F/T Fischer -Tropsch
Methanol & PlasticsUltra Clean Diesel
Saline Aquifer/
EOR
AFC Alkaline Fuel CellH2Sx Sulphur compoundsCO2 Carbon DioxideH2 Hydrogen
Copyright BCG Energy 2009
H2
Thank you from HTC
Global CO2 Pioneers –
- HTC’s CO2 partners/ mentors
Dr. Paitoon Tontiwachwuthikul Dean of
Engineering – UofR
Has published over 180 peer reviewed papers on CO2
capture
Key role in establishing the ITC in Regina
Key role in organizing the GHG 7 Conference
Current leader of the CO2 capture program at UofR
Dr. Malcolm Wilson – Director of Energy &
Environment at the UofR
Founding member of Intergovernmental Panel on
Climate Change (IPCC) – which was a co-recipient of the
Nobel prize with Al Gore (Nov 07)
A recognized global pioneer in CCS and advisor to
Governments, Industry and organizations over the last 20
years