india’s last-mile connectivity chain for hawkers.pdf · gherkins stowage factor: 2 to 3 m3 per...

26
India’s Last-mile Connectivity Captain Pawanexh Kohli

Upload: others

Post on 15-Aug-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

India’s Last-mile Connectivity

Captain Pawanexh Kohli

Page 2: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Village

Collection

Centre

TMS TrucksCity

Consolidation

Centre

F&V Carts

Local Cooling

Feeding Points

City

Consolidation

Centre

Farmers

Farmers

Is there a change possible here?

Page 3: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Food Saleable Quality

Moisture

Shrinkage Firmness

Color

Rot Disease

Captain Pawanexh Kohli

Page 4: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Quality

Humidity

Temperature

Control

Packing &

Hygiene

A thermally

controlled vending

Cart brings all the

factors into play –

For the common

Street Hawker.

Captain Pawanexh Kohli

Page 5: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

A Street Vending cart that will Provide the following

Utilising optimal designing, Passive Cooling System,

Portable and Reusable technology.

Protective Insulation

Thermal Cooling

Quality Preservation

Aesthetic Appeal

Captain Pawanexh Kohli

Page 6: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

• Double skin with PUF insulation.

• Compartmented for storage.

Carts with canopy, double skinned and insulated from harsh

environment.

• Encapsulated thermal cells store cooling from ordinary freezers or any ice factory outlet.

Cooling packs using Phase Change Material – thermal storage cells.

• Rickshaw Model and Push Cart Models.

• Offers advertising space on sides & roof.

Mobile and static in accordance with street

vending norms.

Captain Pawanexh Kohli

Page 7: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Qty 98 kgs in cart, 28 kgs as control in open.

No pre-cooling of F&V done.

Product drop in Temp 0.55 deg C / hr.

Max Weight loss avg1.3%.

Vs 4.8 % in ambient product.

No Spoilage / dump

Captain Pawanexh Kohli

Page 8: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Captain Pawanexh Kohli

Page 9: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Left side with Passive Cooling

Right in ambient of 25 ºC

Captain Pawanexh Kohli

Page 10: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Left side with Passive Cooling

Right in ambient of 25 ºC

Captain Pawanexh Kohli

Page 11: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Left side with Passsive Cooling

Right in ambient of 25 ºC

Captain Pawanexh Kohli

Page 12: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Validate the concept - confirm the temperature range & retention of Fresh gherkin.

Confirms that gherkins stayed fresh and saleable for a 24 hours period

The temperature retained at less than 12 ºC while in ambient it raised to 25 ºC.

Trial Confirms that with proper application of Passive Cooling Medium, temperature control is applied.

Date Time Box Internal °C Gherkin °C Gherkin in

Ambient °C

Hour 2 12.06.08 9.30PM 8.1 7.6 17

Hour 4 12.06.08 11.30PM 7.7 16

Hour 6 13.06.08 1.30AM 7.8 17.5

Hour 8 13.06.08 3.30AM 8.2 7.9 20

Hour 10 13.06.08 5.30AM 7.9 20

Hour 12 13.06.08 7.30AM 7.9 20

Hour 14 13.06.08 9.30AM 8.5 9.1 22

Hour 16 13.06.08 11.30AM 8.8 22

Hour 18 13.06.08 1.30PM 10.2 24

Hour 20 13.06.08 3.30PM 13.8 10.5 24

Hour 22 13.06.08 5.30PM 10.7 24

Hour 24 13.06.08 7.30PM 11.9 25

RECORD 1

Captain Pawanexh Kohli

Page 13: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Gherkins stowage Factor:

2 to 3 m3 per ton.

70 to 105 ft3 per ton.

Gherkin Respiration rate:

@ 10 °C, 60 watts per ton, 10 ml CO2/kg/h

@ 15 °C, 96 watts per ton, 16 ml CO2/kg/h

@ 20 °C, 141 watts per ton, 24 ml CO2/kg/h

@ 25 °C, 168 watts per ton, 28 ml CO2/kg/h

Gherkin Water Content:

96% water, Specific heat (kJ/kg/°C) 4.06

Gherkin Other Properties:

Ethylene– Low Producer, Ethylene sensitivity – High, Freezes at -0.5 °C

Ice Compatible – No, Optimal RH – 90 – 95%, Impact/Pressuresensitive.

Gherkin Optimal Conditions:

Stored at 7 to 12 °C / 90 – 95% RH, lasts from 10 to 14 days.

Benefit of Controlled Atmosphere, Fair (+7 days).

Sensitive to contamination by fats and oils.

Left unexposed in ambient, un-processed Gherkin will loose value within 24-30 hours. They are very susceptible to mold and other micro loads.

With proper post harvest care, Gherkins can last 10 to 14 days.

Captain Pawanexh Kohli

Page 14: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

30

40

50

60

70

80

90

100

12:4

8

12:5

5

13:0

3

13:1

0

13:1

8

13:2

5

13:3

3

13:4

0

13:4

8

13:5

5

14:0

3

14:1

0

14:1

8

14:2

5

14:3

3

14:4

1

14:4

8

14:5

6

15:0

3

15:1

1

15:1

8

15:2

6

15:3

3

15:4

1

15:4

8

15:5

6

16:0

3

16:1

1

16:1

8

16:2

6

16:3

3

16:4

1

16:4

8

16:5

6

17:0

3

17:1

1

Te

mp

ºC

Temp-Time Graph - IRCTC Trials

Rice

Dal

Mix Veg

Roti

Chamber Temp

Room Temp

PCM Temp

Room Temp

Captain Pawanexh Kohli

Page 15: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

In live 48 hours transit of fresh produce, maintained

below 10 ºC for 24 hours and sustained high RH%.

Captain Pawanexh Kohli

Page 16: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Energy storage in kWh indicates cost of energy used with added cost of service provision.

TypePhase Change

temp ºCContents

Operating Temp ºC

Density (kg/m3) Liquid

Latent Heat (kJ/Kg)

FlammabilityQty per kWh

(kg)

Negative -26

Ino

rgan

ic S

alts

-25 to -26 1280 205 No 23

Negative -23 -22 to -24 1180 210 No 18

Negative -19 -17 to -21 1170 200 No 18

Negative -7 -7 to -5 1120 230 No 16

Frost 0 -1 to +1 1010 300 No 12

Positive 22 21 to 23 1540 185 No 19

Positive 24 23 to 25 1540 185 No 19

Positive 29 27 to 29 1550 190 No 19

Positive 58 57 to 59 1290 250 No 15

Positive 89 87 to 89 1540 180 No 20

Captain Pawanexh Kohli

Page 17: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Though entirely design dependant, one large cart

would use from 15 to 30 kgs of PCM (1.1 to 2.2 kWh

of energy).

This would suffice between 12 to 16 hours of

cooling or heating duration, with about 100 door

openings of 10 secs each.

Any limitation in duration, would still bring benefits

when compared to existing uncontrolled system.

PCM does not require any maintenance, has no

machinery component, and simple to use once

charged.

Captain Pawanexh Kohli

Page 18: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Improved design of on road street hawking carts.

No complicated machinery to confuse the hawker.

Reusable on a daily basis after recharging.

Provides aesthetics and hygiene to an age old retail

business.

Allows the common hawker to compete with

organised retail.

Reduces last mile wastage of food.

Brings viable and visible support to poor man – with

the support of the government.

Captain Pawanexh Kohli

Page 19: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Thermally Controlled Vending Carts

Protects Hawkers Product

Allows Portability

Brings Technology

Offers Hygiene

Enhances Income

Captain Pawanexh Kohli

Page 20: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Technology

Cart designs by

Captain Pawanexh Kohli

Page 21: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Captain Pawanexh Kohli

Cart designs by

Page 22: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Captain Pawanexh Kohli

Cart designs by

Page 23: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Captain Pawanexh Kohli

Cart designs by

Page 24: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

Captain Pawanexh Kohli

Cart designs by

Page 25: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,
Page 26: India’s Last-mile Connectivity Chain for Hawkers.pdf · Gherkins stowage Factor: 2 to 3 m3 per ton. 70 to 105 ft3 per ton. Gherkin Respiration rate: @ 10 °C, 60 watts per ton,

THANK YOU

Linking the Farm-to-Fork

[email protected] +91-9990399-638