index []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we...

72

Upload: others

Post on 03-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our
Page 2: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

INDEXPRESENTATION

SOLAR THERMAL ENERGYFLAT SOLAR COLLECTORS

SUPPORT STRUCTURE

ADVANTAGES OF TERMICOL COLLECTORS

TERMOSYPHON UNITS

FORCED UNITS

ADVANTAGES OF TERMICOL’S SYSTEMS

STORAGE TANKS

8

11

4

5

12

28

14

29

31

36

37

38

39

40

41

16

1734

32

9

20

22

24

26

27

6

12

22

28

36

33

Page 3: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

ACCESSORIES SOLAR THERMAL ENERGY

PANELES SOLARES PARA PISCINAS

SOLAR PANELS FOR SWIMMING POOLS

PHOTOVOLTAIC SOLAR ENERGY

AIR HEAT PUMPS

BIO MASS

ADVANTAGES TERMICOL BIOMASS

HEADQUARTERS AND OTHER LOCATIOS

50

51

52

53

43

44

45

45

46

47

48

48

48

49

49

49

56

58

6061

64 65

70

42

48

54

57

62

55

42

50

66

67

68

www.termicol.es

Page 4: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

PRESENTATIONIt is a pleasure for us to present our 2016 products catalogue, which consolidates those important changes which were done in the previous year. These changes are intended to reinforce our leadership in Spain and our international expansion.

The company Since 2001, Termicol has been dedicated to designing, manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our factory and headquarters are located in Seville, and our modern production process has a capacity for over 200,000 square meters of flat-plate solar collectors.

We have a highly-qualified and experienced client service team. Our success is based on offering a wide range of products, the pursuit of quality and continuous improvement, and excellent service. With these values, we have become the market leader in Spain, where we have the best professionals throughout the country. And with them, we are expanding internationally, with a presence already in more than twenty countries on four continents.

Complete and competitive rangeTermicol offers systems both for small standardized installations for private use and custom-designed solutions for larger installations, such as for hotels and industrial buildings. Our catalogue can offer clients all possible combinations for the energy supply of their homes at competitive prices. We make energy cost-effective.

Quality and continuous improvementTermicol has a quality management system based on the requirements of ISO 9001 and SOLARKEYMARK and AENOR Brand N certifications. The evolution of these systems has been based on our continuous improvement of processes with the aim of exceeding client satisfaction by offering high-quality, reliable products, and we consider them to be essential tools in striving for excellence in our processes and products.

Service and technical supportClients are the cornerstone of our business. Our before- and after-sales service is immediate. Our technical department has extensive experience in helping clients to select the best solutions for them. The projects team works on both small and large installations and collaborates with installers and technical consultancies with whom Termicol, as a specialist in solar energy systems, shares ideas and develops them with the best professionals in the sector.

The energy that gets us moving

Thermal Solar Energy

Photovoltaic Solar Energy

Air heat Pumps

Biomass

4

Page 5: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 5

‘SAVINGS AND QUALITY OF LIFE’The energy that comes from the sun is the most economical and cost-effective. Its ability to produce heat enables us to provide comfort at low cost.

THERMAL SOLAR ENERGY

WHY CHOOSE SOLAR THERMAL ENERGY? WHAT DOES TERMICOL OFFER?The sun is the main energy source of the Earth, giving rise to most of the primary energies we use: fossil fuels, biomass, wind. All of these are consequences of the existence of the sun and its relative proximity. Direct use of it also enables us to obtain immediate benefi ts in the form of electricity or heat. This latter form of harnessing the sun is the most economical option for producing thermal energy.

While other systems need to consume energy during the process of producing heat, solar energy systems enable this to be carried out without the need to use other types of energy.

The ability of these systems to generate heat can reach levels of coverage, depending on location, of up to 70% of demand. The cost of a kilowatt hour generated offsets the investment (systems can pay for themselves within a few years with the savings made) and reduces maintenance costs. This cost is, without doubt, the lowest of any means of thermal generation during the long useful life of these reliable and sustainable systems.

Termicol offers an extensive range of solar thermal energy products for all types of solutions:

Three ranges of fl at-plate solar collectors.

All types of support structures.

Prefabricated systems, such as thermosyphon, forced-circulation and drain-back.

Storage tanks of all sizes and systems.

All types of accessories for solar thermal energy installations.

Panels and accessories for swimming pool heating systems.

www.termicol.es | 5

Page 6: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

The grid confi guration is valid for any solar energy installation because of its reduced load losses.

High-strength ultrasonic welding.

Four connection points for assembly in any confi guration: series, parallel or array.

GRID-TYPE

Grid-type fl at-plate solar collectors consist of a network of tubes in their interior through which a fl uid circulates to convey thermal energy to the point of use. Absorbers consist of several small-diameter vertical tubes connected to two larger-diameter header tubes. Fluid fl ows in parallel in the same way through all of the tubes as a result of the ratio between the two tube widths.

One of the main characteristics of this type of absorber is the reduced loss of dynamic load that it exerts on the fl uid fl owing inside. This makes it suitable for use in thermosyphon circulation systems.

Another important characteristic is the possibility of connecting them in arrays by means of the four side inlets they have, achieving a similar confi guration to the unit collector, only larger. By doing so, signifi cant savings can be made due to the reduced number of connection elements that are integrated into the installation to which they belong.

01

02

03

Grid-type fl at-plate

01

03

02

6

FLAT-PLATE SOLAR COLLECTORS flat solars

collectors

Page 7: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 7

MEANDER-TYPE

Meander-type fl at-plate solar collectors feature a tube arrangement through which fl uid fl ows in a serpentine manner. In Termicol’s T-MS collector product family, the meander-type absorber consists of a tube connected to two horizontal collectors with larger diameters to provide four connection inlets and enable them to be joined in an array.

One of the main applications of this type of collector is its use in Termidrain systems because of the ease with which air can be extracted from the collector when the system starts operating. It is also suitable for large installations when the design enables it to work in low fl ow.

Meander-type collectors

01

02

www.termicol.es | 7

FLAT-PLATE SOLAR COLLECTORS flat solars

collectors

01 02

Monoband absorber to increase the absorption surface.

Coil with a high number of passes and four inlets to facilitate product installation and connection.

CO

LLEC

TOR

S

Page 8: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

8

Competitive collectors with grid absorbers especially recommended for areas with high solar radiation. Their selective paint coating makes them ideal for thermosyphon systems.

t-ps family Absorber Plate: a copper tube grill with aluminum fi ns welded on by ultrasound.

Treatment: selective solar paint.Anodized aluminum profi les. Insulation: glass wool.Press fi tting connection. Low iron content tempered solar glass.

Model Description confi guration net area (m2) rp €

T20PS Selective paint fl at collector standar - Grid collector Vertical

1,9 465T25PS Selective paint fl at collector large - Grid collector 2,4 565

T20PSH Selective paint fl at collector standar - Grid collector Horizontal

1,9 540T25PSH Selective paint fl at collector large - Grid collector 2,4 600

technical characteristics

energetic characteristics

Models and prices

Vertical models Horizontal models

Models t20ps t25ps t20psh t25psh

Length (mm) 2130 2130 970 1200Width (mm) 970 1200 2130 2130

Absor. Length. (mm) 2057 2057 903 903Thickness (mm) 83 83 83 83Gross Area (m2) 2,1 2,5 2,1 2,6

Aperture Area (m2) 1,9 2,4 1,9 2,4Empty weight (kg) 35 39 36 40Fluid capacity (l) 1,02 1,27 0,95 1,05

effi ciency t20ps t25ps t20psh t25pshη 0,774 0,758 0,774 0774

K1 (W/ Km2) 6,80 5,54 6,80 6,80K2 (W/ K

2m

2) 0,007 0,022 0,007 0,007

Peak power (Wp) 1455 1789 1455 1455

insulation and protection Frame anodized aluminum

Cover material Tempered solar glass Insulation Glass wool 40 mm

BASIC RANGE FLAT SOLAR COLLECTORS flat solars

collectors YEARS

W

ARRANTY

Page 9: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 9

Ultra-selective collectors with grid absorbers that ensure excellent yield in low solar radiation areas, making them ideal for thermosyphon systems and suitable for any type of installation.

technical characteristics

Models and prices

energetic characteristics

Vertical models Horizontal models

Models t20us t25us t20ush t25ush

Length (mm) 2130 2130 970 1200Width (mm) 970 1200 2130 2130

Absor. Length. (mm) 2057 2057 903 903Thickness (mm) 83 83 83 83Gross Area (m2) 2,1 2,5 2,1 2,6

Aperture Area (m2) 1,9 2,4 1,9 2,4Empty weight (kg) 35 39 36 40Fluid capacity (l) 1,02 1,27 0,95 1,05

effi ciency t20us t25us t20ush t25ushη 0,801 0,79 0,801 0,801

K1 (W/ Km2) 3,93 3,49 3,93 3,93K2 (W/ K2m2) 0,026 0,018 0,026 0,026

Peak power (Wp) 1505 1865 1505 1505

insulation and protection Frame anodized aluminum

Cover material Tempered solar glass Insulation Glass wool 40 mm

t-us familyAbsorber Plate: a copper tube grill with aluminum fi ns welded on by ultrasound.

Treatment: ultra selective. (Absorptivity: >95%, Emissivity: <5%).Anodized aluminum profi les.Insulation: glass wool.Press fi tting connection. Low iron content tempered solar glass.

Model Description confi guration net area (m2) rp €

T20US Ultra-Selective paint fl at collector standar - Grid collector Vertical

1,9 580T25US Ultra-Selective paint fl at collector large - Grid collector 2,4 675

T20USH Ultra-Selective paint fl at collector standar - Grid collector Horizontal

1,9 590T25USH Ultra-Selective paint fl at collector large - Grid collector . 2,4 685

EXCEL RANGE FLAT SOLAR COLLECTORS flat solars

collectors

CO

LLEC

TOR

S

YEARS

W

ARRANTY

Page 10: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

10

t-Ms familyAbsorber Meander with single aluminum fi ns welded on by laser.

Treatment: ultra selective.(Absorptivity: >95%, Emissivity: <5%).Anodized aluminum profi les. Insulation: glass wool.Press fi tting connection.Low iron content tempered solar glass.

technical characteristics Vertical models Horizontal models

Models t20Ms t25Ms t20Msh t25Msh

Length (mm) 2130 2130 970 1200Width (mm) 970 1200 2130 2130

Absor. Length (mm) 2088 2057 950 1180Thickness (mm) 83 83 83 83Gross Area (m2) 2,1 2,5 2,1 2,5

Aperture Area (m2) 1,9 2,4 1,9 2,4Empty weight (kg) 32 39 34 38Fluid capacity (l) 1,29 1,27 1,25 1,42

effi ciency t20Ms t25Ms t20Msh t25Mshη 0,812 0,813 0,812 0,812

K1 (W/ Km2) 3,812 3,674 3,812 3,812K2 (W/ K2m2) 0,021 0,019 0,021 0,021

Peak power (Wp) 1518 1911 1518 1518

Model Description confi guration net area (m2) rp €

T20MS Standard selective paint fl at collector - Grid collector Vertical

1,9 660

T25MS Selective paint fl at collector for big installations - Grid collector 2,4 760T20MSH Standard selective paint fl at collector - Grid collector

Horizontal1,9 660

T25MSH Selective paint fl at collector for big installations - Grid collector 2,4 760

insulation and protection Frame anodized aluminum

Cover material Tempered solar glass Insulation Glass wool 40 mm

energetic characteristics

Models and prices

Ultra-selective collectors with meander absorbers that provide high yield in any type of solar radiation area. Recommended for drain-back systems and large installations.

EXCEL RANGE FLAT SOLAR COLLECTORS flat solars

collectors YEARS

W

ARRANTY

Page 11: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 11

technical characteristics Vertical models

Models t8s t10s

Length (mm) 2130 2130Width (mm) 970 1200

Absor. Length (mm) 2057 2057Thickness (mm) 100 100Gross Area (m2) 2,1 2,5

Aperture Area (m2) 1,9 2,4Empty weight (kg) 37 38Fluid capacity (l) 1,02 1,05

effi ciency t8s t10sη 0,803 0,818

K1 (W/ Km2) 3,66 4,1K2 (W/ K2m2) 0,015 0,001

Peak power (Wp) 1518 1923

Model Description Gross area net area (m2) rp €

T8S Standard ultraselective fl at collector - Meander collector 2,1 1,9 635T10S Ultraselective fl at collector for big installations - Meander collector 2,6 2,4 745

insulation and protection Frame anodized aluminum

Cover material Tempered solar glass Insulation Glass wool 50 mm

energetic characteristics

Models and prices

Ultra-selective collectors with grid absorbers that provide yield levels that are suitable for highly adverse climates and areas of solar radiation.

t-s familyAbsorber Plate : a copper tube grill with aluminum fi ns welded on by ultrasound.

Treatment: ultra selective.(Absorptivity: >95%, Emissivity: <5%).Anodized aluminum profi les. Insulation: super insulated glass wool Press fi tting connection. Low iron content tempered solar glass.

PREMIUM RANGE FLAT SOLAR COLLECTORS flat solars

collectors

CO

LLEC

TOR

S

YEARS

W

ARRANTY

Page 12: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

12

flat roof

GALVANIZEDCOLLECTORSSUPPORT STRUCTURE structures

collectors

Modelos y precios

Steel L profi les

position collector Units reference rp € collector reference rp €

VERTICALT20PST20UST20MS

1 EST1-T20 180

T25PS T25UST25MS

EST1-T25 1802 EST2-T20 200 EST2-T25 2103 EST3-T20 290 EST3-T25 3004 EST4-T20 420 EST4-T25 4355 EST5-T20 505 EST5-T25 5256 EST6-T20 595 EST6-T25 620

position collector Units reference rp € collector reference rp €

HORIZONTALT20PSH T20USHT20MSH

1 EST1-T20H 145 T25PSH T25USHT25MSH

EST1-T25H 1502 EST2-T20H 250 EST2-T25H 2553 EST3-T20H 360 EST3-T25H 370

Models and prices

Connection between modular arrays

Structures for collector arrays on fl at roofs.Hot-dip galvanized steel.Durable and economical.Suitable for areas with benign environments.Clamping profi les on triangles adjustable to 40°, 45° and 50° (contact us for different angles).

Page 13: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 13

tiled roof

roof fi xings

GALVANIZEDCOLLECTORSSUPPORT STRUCTURE structures

collectors

Models and prices position collector Units reference rp € collector reference rp €

VERTICALT20PST20UST20MS

1 ESC1-T20 155

T25PS T25UST25MS

ESC1-T25 1552 ESC2-T20 175 ESC2-T25 1803 ESC3-T20 245 ESC3-T25 2504 ESC4-T20 350 ESC4-T25 3655 ESC5-T20 420 ESC5-T25 4356 ESC6-T20 490 ESC6-T25 505

position collector Units reference rp € collector reference rp €

HORIZONTALT20PSH T20USHT20MSH

1 ESC1-T20H 127 T25PSHT25USHT25MSH

ESC1-T25H 1302 ESC2-T20H 220 ESC2-T25H 2253 ESC3-T20H 305 ESC3-T25H 315

Note : All galvanized support for tiled roof will be suministrated with the perforated tape.

Perforated steel bands enable the structure to be easily fi xed to the roof to prevent slippage of the collection system. Their fl exibility enables them to easily adapt to any type of tile without reducing their fastening capacity.

perforated band

Structures for collector arrays on tiled roofs.Hot-dip galvanized steel.Durable and economical.Suitable for areas with benign environments.Clamping profi les with different roof grip options. S

TRU

CTU

RES

Page 14: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

14

flat roof Structures for collector arrays on fl at roofs.Extruded aluminum highly resistant to corrosion.Suitable for areas with marine environments.Preassembled clamping profi les adaptable to different angles.Strong and lightweight.Easy installation.

ALUMINUM COLLECTORSSUPPORT STRUCTURE structures

collectors

Front support Connection between modular arrays

position collector Units reference rp € collector reference rp €

VERTICALT20PS T20UST20MS

1 ESTA1-T20 216

T25PS T25UST25MS

ESTA1-T25 2162 ESTA2-T20 252 ESTA2-T25 2633 ESTA3-T20 376 ESTA3-T25 3914 ESTA4-T20 500 ESTA4-T25 5255 ESTA5-T20 628 ESTA5-T25 6546 ESTA6-T20 747 ESTA6-T25 783

position collector Units reference rp € collector reference rp €

HORIZONTALT20PSH T20USHT20MSH

1 ESTA1-T20H 206 T25PSH T25USHT25MSH

ESTA1-T25H 2112 ESTA2-T20H 345 ESTA2-T25H 3553 ESTA3-T20H 489 ESTA3-T25H 505

Connection of profi les

Models and prices

Page 15: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 15

tiled roof

roof fi xings

Structures for collector arrays on tiled roofs.Extruded aluminum highly resistant to corrosion.Suitable for areas with marine environments.Preassembled clamping profi les adaptable to different angles.Strong and lightweight.Easy installation.

ALUMINUM COLLECTORSSUPPORT STRUCTURE structures

collectors

STR

UC

TUR

ES

Stainless steel fi tting for insertion under roof tiles.Height-adjustable for different tile curvatures.

roof hook

position collector units reference rp € reference rp € reference rp €

VERTICALT20PST20UST20MS

1 ESCA1-T20 62 ESCAO1-T20 129 ESCAST1-T20 1852 ESCA2-T20 103 ESCAO2-T20 165 ESCAST2-T20 2253 ESCA3-T20 149 ESCAO3-T20 242 ESCAST3-T20 3244 ESCA4-T20 211 ESCAO4-T20 340 ESCAST4-T20 4535 ESCA5-T20 263 ESCAO5-T20 417 ESCAST5-T20 5586 ESCA6-T20 314 ESCAO6-T20 479 ESCAST6-T20 659

position collector units reference rp € reference rp € reference rp €

VERTICALT25PST25UST25MS

1 ESCA1-T25 62 ESCAO1-T25 129 ESCAST1-T25 1852 ESCA2-T25 113 ESCAO2-T25 175 ESCAST2-T25 2373 ESCA3-T25 165 ESCAO3-T25 258 ESCAST3-T25 3504 ESCA4-T25 232 ESCAO4-T25 361 ESCAST4-T25 4795 ESCA5-T25 294 ESCAO5-T25 443 ESCAST5-T25 6036 ESCA6-T25 345 ESCAO6-T25 510 ESCAST6-T25 716

position collector units reference rp € reference rp € reference rp €

HORIZONTAL

T20PSH T20USHT20MSHT25PSH T25USHT25MSH

1 ESCA1-T20H 98 ESCAO1-T20H 165 ESCAST1-T20H 2212 ESCA2-T20H 185 ESCAO2-T20H 288 ESCAST2-T20H 4843 ESCA3-T20H 278 ESCAO3-T20H 417 ESCAST3-T20H 5461 ESCA1-T25H 98 ESCAO1-T25H 165 ESCAST1-T25H 2212 ESCA2-T25H 180 ESCAO2-T25H 288 ESCAST2-T25H 4843 ESCA3-T25H 278 ESCAO3-T25H 417 ESCAST3-T25H 546

Without anchorage With adjustable anchorage With adaptable pieceModels and prices

Stainless steel fi tting with threaded bolt that enables the fi tting to be positioned on the structure’s support.

adjustable anchorage

Page 16: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

collector array connection (Batcapt)

adaptation fi ttings (racorbat)

COLLECTORCONNECTION FITTINGS flat solars

collectors

16

The collector outlets consist of 18 mm-diameter compression fi ttings with gas threading. RACORBAT contains the parts necessary for connection to standard plumbing fi ttings.

Termicol supplies all elements necessary to confi gure collector arrays. The BATCAPT contains the purge, safety and closure systems necessary for proper assembly of the installation.

Description Content reference rp €

Array accessory set

Compression cap 18 copper pipe, reducing bush 3/4” M to 1/2” F, male fi tting nipple 18-3/4”, cross Array accessory set connector 3/4” F, ball valve 1/2” M-F butterfl y. Automatic air relief

purger 3/8” M, brass thermowell housing 1/2”, ball valve 3/4” M-F butterfl y, solar safety valve 6 bar 1/2” “ F, solar and bushing sleeve 3/4” F to 1/2” F

BATCAPT-02 109

Hydraulic circuit adapter set Male fi tting Nipple 18-3/4” (4 units) RACORBAT-02 10

Models and prices

Page 17: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 17

A connection system that reduces the amount of pipework that feeds each area of the collection fi eld. It is limited to a maximum number of elements to prevent loss of performance in the fi nal collectors and pressure due to expansion in their collecting pipes.

The main characteristic of parallel connection is that performance in the collection system is more uniform with all areas working with similar inlet and outlet temperatures. The main drawback is that they produce greater total fl ow rates.

When a collector or collector array is connected in series to another collector or collector array, a higher outlet temperature is produced, thereby reducing total fl ow rates. Not all of the collectors however work with the same performance.

Mixed connection is suitable for large installations, enabling a reduction in total fl ow rate while partially making performance uniform in different areas of the installation.

Collectors can be connected in different ways. This makes it possible to achieve different thermal behavior to suit the application for which energy is being supplied.

array or row

parallel

series

series - parallel

CO

NN

ECTI

ON

S

ARRAYCOLLECTORS CONFIGURATIONS flat solars

collectors

www.termicol.es | 17

Page 18: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

18

SYSTEMSCOLLECTORS CONFIGURATIONS flat solars

collectors

A suitable system for collective consumption of hot water in hotels, hospitals, sports centers, etc.

The centralization of production improves system effi ciency and reduces overall energy consumption.

A recommended system for residential buildings with its main advantage lying in the individualization of storage, keeping the solar generation system centralized.

To control individual consumption, it is necessary to install an energy meter at the entrance of each dwelling. There are two types: with external heat exchanger to separate the heating circuit from the distribution circuit and without heat exchanger, which is only recommended in small buildings.

Installation recommended for residential buildings in which space is scarce in dwellings.

The installation of an buffer storage tank partially centralizes storage, enabling the size of the individual tank to be reduced.

system with centralized storage

Distributed storage

A suitable system for collective consumption of hot water in hotels, hospitals, sports centers, etc.

The centralization of production improves system effi ciency and reduces overall energy consumption.

Distributed storage and intermediate inertia storage tank

Page 19: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 19

CO

NFI

GU

RAT

ION

S

SYSTEMSCOLLECTORS CONFIGURATIONS flat solars

collectors

Solar thermal systems with collectors are suitable for providing low temperature heating.

The use of a combined storage tank can produce DHW and heat simultaneously, thereby saving on space and reducing the investment.

The low thermal temperature required by indoor swimming pools makes solar thermal systems with glazed collectors suitable for heating swimming pool tanks.

When required to be used throughout the year, the yields obtained are very high as collection is carried out at low average temperatures.

This system enables the swimming season to be extended by two or three months either side of summer. Unglazed plastic collectors are suitable for this type of pool, enabling spring and autumn temperatures to approach those of the summer months.

a centralized system for combined DhW and heating

a solar thermal system for indoor swimming pools

a solar thermal system for outdoor swimming pools

Page 20: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

ADVANTAGES OF TERMICOL COLLECTORS

installation - Compression fi ttings with brass rings (included with the collector).- Dismountable aluminum frame of easy maintenance. - Lateral canal of the frame that facilitates its integration.

Versatility and Design - In two sizes of vertical position as well as in horizontal. - Lateral air ducts against condensation.- Two types of treatment: selective paint and ultraselective coat. - Roof top integrated system.- Large size solar collectors.

Durability and Aesthetics- Rigid, robust and shock resistant. - High resistant tempered solar glass. - Meander absorber with ultrasonic welding. - Frame sealing with EPDM joint. - A more aesthetic exterior fi nish in 100% anodized aluminum.- Corner trims that protect the collectors. - Retractable packaging with reinforced corners.

20

Page 21: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 21www.termicol.es | 21

Installations with Termicol solar collectors

Page 22: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

22

THERMOSYPHONUNITS thermosyphon

units

HIGH TANK

ta 300 pf Serie F

Ejemple of nomenclature:

Termicol’s Range of thermosyphon units with high tanks offers energy perfomance climates, these systems provide DHW at the lowest possible cost.

The solar fl uid used also has properties that extend the life of the system. Its corrosion inhibitors prevent damage to the primary circuit. Its use is required to maintain the warranty.

“One kit, one reference”

150 liters units (1/2 users) collector reference rp €

Selective T20PS TA150PF-01 1.530

Ultraselective T20US TA150UF-01 1.600

Selective T25PS TA150PFM-01 1.595

Ultraselective T25US TA150UFM-01 1.685

300 liters units (5/6 users) collector reference rp €

Selective T25PS TA300PFX-01 2.030Ultraselective T25US TA300UFX-01 2.100

Selective T20PS x 2 TA300PF-01 2.360Ultraselective T20US x 2 TA300UF-01 2.485

Selective T25PS x 2 TA300PFM-01 2.480Ultraselective T25US x 2 TA300UFM-01 2.630

200 liters units (3/4 users) collector reference rp €

Selective T20PS TA200PFX-01 1.610Ultraselective T20US TA200UFX-01 1.690

Selective T25PS TA200PF-01 1.695Ultraselective T25US TA200UF-01 1.770

Selective T20PS x 2 TA200PFM-01 2.035Ultraselective T20US x 2 TA200UFM-01 2.160

1 or 2 collectors1 storage tank1 accessories set1 support high tank1 set of connections storage tank collector

components

Volume torage tankTermicol

High tank Collector in selective paint

Page 23: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 23

UN

ITS

Termicol’s thermosyphonswith tank have the advantage of a reduced number of connections. Energetically, this is the most effi cient confi guration as the circulation of the fl uid per thermosyphon effect is easier with this confi guration of tank and collector.

connection scheMe for hiGh tank

Características

1 COPPER PIPE COMPRESSION PLUG 2

3 CARDBOARD JOINT 4

6 BRASS “T” ¾”- 1/2” – ¾” F 1

7 WIPPLE 3/4” - 1/2” 2

11 PHY 3/4” 2

46 NIPPLE ¾ PLANE”- ¾” 2

47 NIPPLE ¾ PLANE”- ¾ -18 mm 2

49 DIELECTRIC COMPLING ¾’ M-H 2

53 JOINT M 3/4”- 1/2” 1

54 SAFETY GROUP 8 bar ½” 1

55 SAFETY VALVE 2,5 bar ½” 1

THERMOSYPHONUNITS thermosyphon

units

SUPPORT FOR HIGH TANK

Resistant, due to its inverted omega form profi les.

Easy to assemble, due tu its premounted confi guration.

Versatile, suitable for fl at o tile roof.

“Zinc-plated steel support”

new

Page 24: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

24

THERMOSYPHONUNITS thermosyphon

unitsLOW TANK

Example of nomenclature:

150 liters units (1/2 users) collectors reference rp €

Selective T20PS TB150PF-01 1.530

Ultraselective T20US TB150UF-01 1.600

Thermosyphon systems with low tanks enable greater integration with the roof and higher energyperformance. Slower thermosyphon circulation enables hot water to be obtained in less time.

200 liters units (3/4 users)

‘One standfor all roofs’

300 liters units (5/6 users)

tB 200 uf Serie F

horizontal kit (3/4 users) collectors reference rp €

UltraselectiveT25USH TB200UFH-01 1.850

1 or 2 collectors1 storage tank1 accessories set1 support structure for low tank1 set of connections storage tank - collectors

components

collectors reference rp €

Selective T25PS TB200PF-01 1.695

UltraselectiveT25US TB200UF-01 1.770

Selective T20PS TB200PFX-01 1.610Ultraselective T20US TB200UFX-01 1.690

collectors reference rp €

Selective T20PS x 2 TB300PF-01 2.360Ultraselective T20US x 2 TB300UF-01 2.485

Selective T25PS x 2 TB300PFM-01 2.480Ultraselective T25US x 2 TB300UFM-01 2.630

Volume torage tankTermicol

Low tank Ultraselective collector

Page 25: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 25

UN

ITS

Termicol thermosyphon kits with low tank allow a height reduction which reduces the visual impact on a fl at roof. This low confi guration of the tank makes a slower thermosyphon circulation which enables hot water to be obtained in less time.

connection scheMe for loW tank

caracterÍsticas

1 COPPER PIPE COMPRESSION PLUG 18 2

3 CARDBOARD JOINT 4

5 NIPPLE 3/4” 2

7 NIPPLE 3/4” - 1/2” 1

11 PLUG 3/4” 1

17 ANTI-THERMOSYPHON VALVE 3/4” 1

44 ELBOW 90 3/4” M-F 1

46 NIPPLE 3/4” PLANE – 3/4” 2

47 NIPPLE 3/4” PLANE – 18 mm 2

49 DIELECTRIC COUPLING 3/4” M-F 2

53 JOINT M 3/4”- F 1/2” 1

54 SAFETY GROUP 8 bar ½“ 1

55 SAFETY VALVE 2,5 bar ½“ 1

THERMOSYPHONUNITS SUPPORT FOR LOW TANK

Resistant, with steel angles 3 mm thick.

Versatile, suitable for flat or tile roof.

“ zinc-plated steel support ”

new

thermosyphon units

Page 26: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

26

THERMOSYPHONUNITS ACCESSORIESEnameled horizontal storage tanks

Model Capacity (liters) Exterior protection Reference RP €

ATZ150I 150 Galvanized and lacquered steel ACUEZ150-01 600ATZ200I 200 Galvanized and lacquered steel ACUEZ200-01 750ATZ300I 300 Galvanized and lacquered steel ACUEZ300-01 900

With double casing

Model A B C

ATZ 150I 1023 575 500ATZ 200I 1268 575 500ATZ 300I 1784 575 500

Dimensions

Accessories for thermosyphon units

Description Referencie RP €

Thermosyphon electrical kit 1,5 kW RESYTER-01 45Thermosyphon electrical kit 2,5 kW RESYTER-03 50

Controller for electrical element CENTRALI-13 200

Water treatment systems

Description Reference RP €

Polyphosphates cartridge filter 3/4¨ FILTRO-01 62

Polyphosphates cartridge filter 3/4¨

* Suitable for outside installation.

** Sanitary polyphosphates are used in water treatment due to their high performance in these processes:

- They stabilize carbonates up to 80º avoinding scales. - They melt the existing scales. - Prevent precipitation of other products sequestering heavy metal ionssuch as iron and manganese. - Avoid red waters.

Accessories for thermosyphon units

Description Reference RP €

Thermostatic mixing valve VALVTERM-01 95Release valve (PT safety) VALVDESC-01 45

“Fluidosol” concentrated antifreeze 2 l ANTICONG-05 15“Fluidosol” concentrated antifreeze 10 l ANTICONG-01 75

Thermosyphon Units

Page 27: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 27

UN

ITS

THERMOSYPHONUNITS MAINTENANCE

Maintenance of the kitsAll installations must go through a monitoring and maintenance plan (RITE-IT 3.3) so that the equipment can perform well continously. A few simple actions will make the equipment last longer as well as perform the same way over the years.

equipmentfrequence (months)

Description

Glass 6 Visual inspection for condensation and dust

Joints 6 Visual inspection, deterioration, corrosion and tighten screws

Connections 6 Visual inspection for leakages

Supports 6 Visual inspection, deterioration, corrosion and tighten screws

Storage tank 12 Muds at the bottom

Magnesium anode 12 Deterioration checkup

internal protection

eXternal protection

As a manufacturer and designer of solar systems, Termicol includes in its equipment protection systems that make their lives longer - enameled: the steel of the storage tanks is enameled to reduce corrosion

- Magnesium anode: the cathodic protection system is an active protection system which consumes this protective element: the anode. Therefore, it is mandatory to replace it in time, according to the characteristics of the water forconsumption.

As an addition to the protection elements integrated in theTermicol equipment, we recommend the installation of an external system placed at the inlet of the equipment. The elimination of calcium ions before entering the tank is an economical and efficient way to protect the storage systems.

ánode

start upProper start up of the equipment is essential for their right functioning and durability. To do this it is necessary to fill it in correctly and prevent damages at the tank. For this only a a few simple steps shown below must be followed.

Fill in the consumption circuit Pressurize the consumption circuit Fill primary circuit

thermosyphon units

Page 28: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

28

1 COILFORCED UNITS BASIC forced

units

Forced circulation units with all their components ready for installation. This range is the most competitive as the pump and control system is included separately.

150 liters units (1/2 users)

200 liters units (3/4 users)

300 liters units (5/6 users)

‘One kit one reference’

collector structure net area (m2) ref. flat roof ref. tiled roof rp €

T20PS Steel 1,9

TKG1/150PS-01 TKG1/150PSCI-01 2.230T20PS Aluminum TKA1/150PS-01 TKA1/150PSCI-01 2.270

collector structure net area (m2) ref. flat roof ref. tiled roof rp €

T25PS Steel 2,4

TKG1/200PS-01 TKG1/200PSCI-01 2.385T25PS Aluminum TKA1/200PS-01 TKA1/200PSCI-01 2.425

collector structure net area (m2) ref. flat roof ref. tiled roof rp €

Two T20PS Steel 3,8

TKG2/300PS-01 TKG2/300PSCI-01 2.930Two T20PS Aluminum TKA2/300PS-01 TKA2/300PSCI-01 3.050

Components: 1. TERMICOL solar collectors. Models T20PS or T25PS (selective paint).2. Support structures. 3. Storage tank. 4. Expansion vessel.5. Valve and connection accessories. 6. Pumping and regulation system. 7. Antifreeze fl uid. 8. Tester magnesium anode.

Example of nomenclature

tkG1/150 ps

Termicol Nr collectors

Basic Unit

Galvanized structure

Volume Accumulation

Collector Selective

new

Page 29: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 29

1 COIL

U

NIT

S

FORCED UNITS SOLAR STATION forced

units

‘One kit one reference’

Forced-circulation systems with all components ready to install.Easy and quick installation with integrated pump and control system.

collector structure net area (m2) ref. flat roof ref. tiled roof rp €

T20PS Steel

1,9

TIG1/150PS-01 TIG1/150PSCI-01 2.340T20PS Aluminum TIA1/150PS-01 TIA1/150PSCI-01 2.380T20US Steel TIG1/150US-01 TIG1/150USCI-01 2.475T20US Aluminum TIA1/150US-01 TIA1/150USCI-01 2.520

collector structure net area (m2) ref. flat roof ref. tiled roof rp €

T25PS Steel

2,4

TIG1/200PS-01 TIG1/200PSCI-01 2.500T25PS Aluminum TIA1/200PS-01 TIA1/200PSCI-01 2.545T25US Steel TIG1/200US-01 TIG1/200USCI-01 2.700T25US Aluminum TIA1/200US-01 TIA1/200USCI-01 2.750

collector structure net area (m2) ref. flat roof ref. tiled roof rp €

Two T20PS Steel

3,8

TIG2/300PS-01 TIG2/300PSCI-01 3.075Two T20PS Aluminum TIA2/300PS-01 TIA2/300PSCI-01 3.200Two T20US Steel TIG2/300US-01 TIG2/300USCI-01 3.320Two T20US Aluminum TIA2/300US-01 TIA2/300USCI-01 3.400

150 liters units (1/2 users)

200 liters units (3/4 users)

300 liters units (5/6 users)

Components: 1. TERMICOL solar collectors. Models T20US, T25US, T20PS or T25PS. 2. Support structures. 3. Storage tank. 4. Expansion vessel.5. Valve and connection accessories. 6. Pumping and regulation system. 7. Antifreeze fl uid. 8. Tester magnesium anode.

Example of nomenclature:

tia2/300 us ci

Termicol Nr collectors

Solar unit Integrated

Aluminum support structure

VolumeAccumulation

Collector Ultraselective

Tiled roof

new

Page 30: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

30

750 liters units (11/16 users)

500 liters units (7/10 users)

1000 liters units (17/20 users)

forced units

collectors support net area reference fl at terrace reference tile roof rp €

Three T20PS Steel 5,7 TIG3/500PS-01 TIG3/500PSCI-01 4.360Four T20PS Steel 7,6 TIG4/500PS-01 TIG4/500PSCI-01 4.940

Three T20US Aluminum 5,7 TIA3/500US-01 TIA3/500USCI-01 4.575Four T20US Aluminum 7,6 TIA4/500US-01 TIA4/500USCI-01 5.175

collectors support net area reference fl at terrace reference tile roof rp €

Four T25PS Steel 9,6 TIG4/800PS-01 TIG4/800PSCI-01 5.770Five T25PS Steel 12 TIG5/800PS-01 TIG5/800PSCI-01 6.380Four T25US Aluminum 9,6 TIA4/800US-01 TIA4/800USCI-01 6.035Five T25US Aluminum 12 TIA5/800US-01 TIA5/800USCI-01 6.700

collectors support net area reference fl at terrace reference tile roof rp €

Five T25PS Steel 12 TIG5/1000PS-01 TIG5/1000PSCI-01 7.635Six T25PS Steel 14 TIG6/1000PS-01 TIG6/1000PSCI-01 8.220Five T25US Aluminum 12 TIA5/1000US-01 TIA5/1000USCI-01 7.885Six T25US Aluminum 14 TIA6/1000US-01 TIA6/1000USCI-01 8.595

Forced-circulation systems with all components ready to install.Easy and quick installation with integrated pump and control system.

“One kit one reference”

We offer models ranging from 500 l to 1000 l designed for distances between the accumulation and the collecting of up to 30 meters. With anodized aluminum structures with a high mechanical resistance and highly resistant to corrosion.

FORCED UNITSSOLAR STATION 1 COIL

Page 31: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 31

collectors net area reference fl at terrace reference tile roof rp €

Four T25US 9,6 T2IA4/800US-01 T2IA4/800USCI-01 6.250Five T25US 12 T2IA5/800US-01 T2IA5/800USCI-01 6.915

750 liters units (11/16 users)

collectors net area reference fl at terrace reference tile roof rp €

Three T20US 5,7 T2IA3/500US-01 T2IA3/500USCI-01 4.735Four T20US 7,6 T2IA4/500US-01 T2IA4/500USCI-01 5.360Three T25US 7,2 T2IA3/500USM-01 T2IA3/500USMCI-01 5.030Four T25US 9,6 T2IA4/500USM-01 T2IA4/500USMCI-01 5.740

500 liters units (7/10 users)

collectors net area (m2)captación reference fl at terrace reference tile roof rp €

Five T25US 12 T2IA5/1000US-01 T2IA5/1000USCI-01 8.215Six T25US 14 T2IA6/1000US-01 T2IA6/1000USCI-01 8.880Five T25US 12 T2IA5/1000US-02** T2IA5/1000USCI-02** 7.645Six T25US 14 T2IA6/1000US-02** T2IA6/1000USCI-02** 8.265

1000 liters units (17/20 users)

collectors support net area reference fl at terrace reference tile roof rp €

T25PS Steel

2,4

T2IG1/200PS-01 T2IG1/200PSCI-01 2.595T25PS Aluminum T2IA1/200PS-01 T2IA1/200PSCI-01 2.620T25US Steel T2IG1/200US-01 T2IG1/200USCI-01 2.820

T25US Aluminum T2IA1/200US-01 T2IA1/200USCI-01 2.870

Two T20US Aluminum 3,8 T2IA2/200USM-01 T2IA2/200USMCI-01 3.470

collectors support net area reference fl at terrace reference tile roof rp €

T20PS Steel

3,8

T2IG2/300PS-01 T2IG2/300PSCI-01 3.200T20PS Aluminum T2IA2/300PS-01 T2IA2/300PSCI-01 3.310T20US Steel T2IG2/300US-01 T2IG2/300USCI-01 3.450T20US Aluminum T2IA2/300US-01 T2IA2/300USCI-01 3.570

Two T25US Aluminum 4,8 T2IA2/300USM-01 T2IA2/300USMCI-01 3.800

200 liters units (3/4 users)

300 liters units (5/6 users)

UN

ITS

forcedunits

Systems with double coil storage tanks enabling connection to other heating systems.*

FORCED UNITSSOLAR STATION 2 COILS

* These systems are not allowed in the Spanish market.

** Storage tank with small inspection hole.

Page 32: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

32

Forced circulation units with all their components ready for installation.

Forced-circulation system with automatic gravity drainage. Prevents damage inthe collection system due to overheating and freezing. Simple, easy to install andreliable.

characteristics of the hydraulic circuitcharacteristics termiDrain 150 termiDrain 200 termiDrain 300

Solar circuit material Cu Ø int Cu 10 mm - Ø ext 12 mmDistance from the base of the tank to the top of the collector From 3 to 10 m

Total maximum length of the pipe (m) 20

tDa1/300 Ms ci

Termicol

FORCED UNITSTERMIDRAIN forced

units

collectors net area (m2) reference feat roof reference tiled roof rp €

Two T20MS 3,8 TDA2/300MS-01 TDA2/300MSCI-01 3.525

300 liters unit (5/6 users)

DRAINBACK SYSTEMS ONE COIL

collectors net area (m2) reference feat roof reference tiled roof rp €

One T20MS 1,9 TDA1/200MSX-01 TDA1/200MSXCI-01 2.700One T25MS 2,4 TDA1/200MS-01 TDA1/200MSCI-01 2.800

One T20MSH 1,9 TDA1/200MSHX-01 TDA1/200MSHXCI-01 2.700One T25MSH 2,4 TDA1/200MSH-01 TDA1/200MSHCI-01 2.800

collectors net area (m2) reference feat roof reference tiled roof rp €

One T20MS 1,9 TDA1/150MS-01 TDA1/150MSCI-01 2.550

One T20MSH 1,9 TDA1/150MSH-01 TDA1/150MSHCI-01 2.550

150 liters unit (1/2 users)

200 liters unit (3/4 users)

Example of nomenclature:

Aluminium support

Storagevolume

Meander Ultraselectivecollector

Drain Back unit

Tiledroof

Nr Collectors

Page 33: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 33

characteristics of the hydraulic circuitcharacteristics termiDrain 150 termiDrain 200 termiDrain 300

Solar circuit material Cu Ø int Cu 10 mm - Ø ext 12 mmDistance from the base of the tank to the top of the collector From 3 to 10 m

Total maximum length of the pipe (m) 20

i

Termicol

UN

ITS

FORCED UNITSTERMIDRAIN forced

unitsDRAINBACK SYSTEMS DOUBLE COIL

t2Da1/300 Ms c

Nr of coils

Nr collectors

collector net area (m2) reference feat terrace reference tiled roof rp €

One T20MSH 1,9 T2DA1/200MSX-01 T2DA1/200MSXCI-01 2.910One T25MSH 2,4 T2DA1/200MS-01 T2DA1/200MSCI-01 3.015One T20MSH 1,9 T2DA1/200MSHX-01 T2DA1/200MSHXCI-01 2.910One T20MSH 2,4 T2DA1/200MSH-01 T2DA1/200MSHCI-01 3.015Two T20MS 3,8 T2DA2/200MS-01 T2DA2/200MSCI-01 3.465

200 liters unit (3/4 users)

collector net area (m2) reference feat terrace reference tiled roof rp €

Two T25MS 3,8 T2DA2/300MS-01 T2DA2/300MSCI-01 3.835Two T25MS 4,8 T2DA2/300MSM-01 T2DA2/300MSMCI-01 3.995

300 liters unit (5/6 users)

* These systems are not allowed in the Spanish market.

Example of nomenclature:

Tiledroof

Aluminium support

Storagevolume

Meander Ultraselectivecollector

Drain Back unit

Page 34: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

34

ample Range- High and low deposit

versions.- Ranges of selective

collectors and black chrome.

- Support structure for fl at and tiled roofs.

- Storage tanks from 150 to 300 actual liters.

Durability and Design - Vitrifi ed high effi ciency double

jacket tanks.- Storage tank with a galvanized

and lacquered steel lining.- PT valve for double protection

in the consumption circuit (optional).

installation and Maintenance- Numbered structures to

facilitate the mounting. - Storage tank with lateral

handles for easier transportation.

- Low maintenance reliable internal expansion system.

- A connecting system without joints.

THERMOSYPHON

TERMICOL ADVANTAGES THERMOSYPHON UNITS

Page 35: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 35www.termicol.es | 35www.termicol.es | 35

FORCED

ample Range- Storage tank systems from

150 to 1000 liters. - Two ranges: economic and

maximum integration. - Maximum security: electronic

protection and ‘’ drainback ‘’ system.

Durability and Design- Stylized storage tanks that better

effi ciency. - The possibility of extruded

aluminum structures.- Versatile and easy-to-use control

systems.- Predesigned to facilitate your

selection and to optimize production.

installation and Maintenance- Pre-mounted systems, easy

to mount. - All mounting accessories

included. - Factory pre-mounted electrical

system.- In the ESI models: electronic

assistance in starting up. - Magnesium anode tester (in

basic and ESI units).

TERMICOL ADVANTAGES FORCED UNITS

Page 36: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

36

STORAGE TANKSFOR DHW storage tanks

Vertical storage tanks with single fi xed coil for DHW, carbon steel, glazed interior, 5-year warranty. Coil inenameled steel with large exchange surface.

Vitrifi ed storage tanks with a fi xed coilModel capacity (liters) Exterior protection reference rp €

ATK150S 150

Rigid polyurethane and leatherette

ACUK0150-11 730

ATK200S 200 ACUK0200-11 820ATK300S 300 ACUK0300-11 925ATK500S 500 ACUK0500-11 1.295ATK800S 750

Flexible polyurethane and leatherette

ACUK0800-11 1.980ATK1000S 1.000 ACUk1000-11 2.480ATK1500S 1.500 ACUk1500-11 3.250ATK2000S 2.000 ACUK2000-11 3.980ATK2500S 2.500 ACUK2500-11 4.880ATK3000S 3.000 ACUK3000-11 5.380

Vitrifi ed storage tanks with a fi xed coil and integrated solar stationModel capacity (liters) Exterior protection reference rp €

ATK150ESI 150

Rigid polyurethane and leatherette

ACUK0150-12 1.155ATK200ESI 200 ACUK0200-12 1.245ATK300ESI 300 ACUK0300-12 1.350ATK500ESI 500 ACUK0500-12 1.720ATK800ESI 750

Flexible polyurethane and leatheretteACUK0800-12 2.405

ATK1000ESI 1.000 ACUK1000-12 2.950

FIXED COILVertical storage tanks with single fi xed coil for DHW, carbon steel, glazed interior, 5-year warranty. Coil inenameled steel with large exchange surface.

Enameled

new

characteristics 150 l 200 l 300 l 500 l 800 l1000 lBh/Bp

1500 l 2000 l 2500 l 3000 l

Area spiral exchanger (m2) 1,17 1,46 1,60 2,46 2,98 2,98 3,86 4,65 7,20 7,20

Weight (kg) 91 109 123 194 261 283 380 594 717 840Diameter (D mm) 590 590 590 740 900 1000 1120 1260 1445 1450

Height (A mm) 1145 1345 1900 1820 2100 2030 2300 2250 2100 2550

Working Pmax (bar) / Tmax (ºC) 10 bar / 95ºC

Page 37: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 37

STO

RA

GE

TAN

KS

STORAGE TANKSFOR DHW storage tanks

Vitrifi ed storage tanks with a double fi xed spiralModel capacity (liters) Exterior protection reference rp €

ATK200S2 200Rigid polyurethane and leatherette

ACUK0200-13 870ATK300S2 300 ACUK0300-13 1.030ATK500S2 500 ACUK0500-13 1.400ATK800S2 750

Flexible polyurethane and leatherette

ACUK0800-13 2.180ATK1000S2 1.000 ACUK1000-13 2.680ATK1500S2 1.500 ACUK1500-13 3.525ATK2000S2 2.000 ACUK2000-13 4.195ATK2500S2 2.500 ACUK2500-13 5.250ATK3000S2 3.000 ACUK3000-13 5.850

Vitrifi ed storage tanks with a double fi xed coil and integrated solar stationModel capacity (liters) Exterior protection reference rp €

ATK200ESI2 200Rigid polyurethane and leatherette

ACUK0200-14 1.350ATK300ESI2 300 ACUK0300-14 1.495ATK500ESI2 500 ACUK0500-14 1.895ATK800ESI2 750

Flexible polyurethane and leatheretteACUK0800-14 2.660

ATK1000ESI2 1.000 ACUK1000-14 3.160

Vertical storage tanks with double coil for DHW, carbon steel, glazed interior, 5-year warranty. Coils inenameled steel with large exchange surface.

DOUBLE FIXED COILVertical storage tanks with double coil for DHW, carbon steel, glazed interior, 5-year warranty. Coils inenameled steel with large exchange surface.

Enameled

characteristics 200 l 300 l 500 l 800 l1000 lBh/Bp

1500 l 2000 l 2500 l 3000 l

Exchange surface Sinf (m2) 1,02 1,30 2,46 2,98 2,98 3,86 4,65 7,20 7,20

Exchange surface Ssup (m2) 0,73 0,99 1,46 1,63 1,80 1,86 2,26 3,50 3,50Weight (kg) 112 132 223 290 318 417 640 717 925

Diameter (D mm) 590 590 740 900 1000 1120 1260 1460 1460Height (A mm) 1345 1900 1820 2100 2030 2300 2230 2200 2540

Working Pmax (bar) / Tmax (ºC) 10 bar / 95ºC

storage tanks

new

Page 38: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

38

Model capacity (liters) Exterior protection reference rp €

ATK150D 150

Rigid polyurethane and leatherette

ACUK0150-15 660ATK200D 200 ACUK0200-15 715ATK300D 300 ACUK0300-15 850ATK500D 500 ACUK0500-15 1.180ATK800D 800

Flexible polyurethane and leatherette

ACUK0800-15 1.695ATK1000D 1000 ACUK1000-15 2.180ATK1500D 1500 ACUK1500-15 2.950ATK2000D 2000 ACUK2000-15 3.480ATK2500D 2500 ACUK2500-15 4.120ATK3000D 3000 ACUK3000-15 4.580

Direct Storage Tanks

accessoriesDescription reference rp €

Electronic anode from 800 L to 1.500 L ANODO-10 190Electronic anode from 2.000 L to 4.500 L ANODO-11 250

Electronic anode up to 5.000 L ANODO-12 440

Vertical direct storage tanks for DHW, carbon steel, glazed interior, 5-year warranty. Enameled coil with large exchange surface

STORAGE TANKSFOR DHW storage tanks

DIRECT

characteristics 150 l 200 l 300 l 500 l 800 l 1000 l 1500 l 2000 l 2500 l 3000 l

Diameter (D mm) 590 590 700 750 900 1000 1120 1265 1445 1450

Height (A mm) 1125 1320 1210 1800 2100 2070 2300 2230 2220 2540Weight (Kg) 72 79 97 153 223 235 330 470 560 620

Working Pmax (bar) / Tmax (ºC) 10 bar / 95ºC

storage tanks

Page 39: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 39

STO

RA

GE

TAN

KS

Model capacity (liters) Exterior protection reference rp €

ATK 500 S ext 500

Flexible polyurethane with detachable PVC cover

ACUKS0500-11 2.200

ATK 800 S ext 800 ACUKS0800-11 2.950ATK 1000 S ext BH 400mm 1000 ACUKS1000-11 3.200ATK 1500 S ext BH 400mm 1500 ACUKS1500-11 3.400ATK 2000 S ext BH 400mm 2000 ACUKS2000-11 4.995ATK 2500 S ext BH 400mm 2500 ACUKS2500-11 5.395ATK 3000 S ext BH 400mm 3000 ACUKS3000-11 6.150ATK 4000 S ext BH 400mm 4000 ACUKS4000-11 7.950ATK 5000 S ext BH 400mm 5000 ACUKS5000-11 9.200

storage tank with detachable coil

Model capacity (liters) Exterior protection reference rp €

ATK 500 S2 ext 500

Flexible polyurethane with detachable PVC cover

ACUKS0500-13 3.120

ATK 800 S2 ext 800 ACUKS0800-13 4.005ATK 1000 S2 ext BH 400mm 1000 ACUKS1000-13 4.315ATK 1500 S2 ext BH 400mm 1500 ACUKS1500-13 5.370ATK 2000 S2 ext BH 400mm 2000 ACUKS2000-13 6.360ATK 2500 S2 ext BH 400mm 2500 ACUKS2500-13 6.740ATK 3000 S2 ext BH 400mm 3000 ACUKS3000-13 7.515ATK 4000 S2 ext BH 400mm 4000 ACUKS4000-13 9.520ATK 5000 S2 ext BH 400mm 5000 ACUKS5000-13 10.915

storage tank with 2 detachable coils

ENAMELED STORAGE TANKSFOR DHW DETACHABLE COILDirect Vertical storage tank for DHW in carbon steel and interior glaze treatment. 5 years warranty. Copper detachable coil with large exchange surface.

characteristics 500 l 800 l 1000 l 1500 l 2000 l 2500 l 3000 l 4000 l 5000 l

Exchange surface Sinf (m2) 1,26 1,64 1,86 2,16 2,99 3,1 3,3 4 4,5

Exchange surface Ssup (m2) 2,16 2,98 3,13 3,72 4,84 5,9 7 8,5 10

Weight (kg) 750 900 1000 1120 1260 1460 1460 1660 1660

Diameter (D mm) 1930 2100 2070 2300 2230 2200 2540 2610 3210Height (A mm) 310 408 432 585 665 693 848 1075 1200

Working Pmax (bar) / Tmax (ºC) 10 bar / 95ºC

storage tanksstorage tanks

new

Page 40: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

40

AC

UM

ULA

DO

RES

Model capacity (liters) Exterior protection reference rp €

ACUVIX 100 INOX 100

Flexible polyurethane with detachable PVC cover

ACUVIX0100-10 695ACUVIX 150 INOX 150 ACUVIX0150-10 825ACUVIX 200 INOX 200 ACUVIX0200-10 930ACUVIX 300 INOX 300 ACUVIX0300-10 1.410ACUVIX 500 INOX 500 ACUVIX0500-10 2.700ACUVIX 750 INOX 750 ACUVIX0750-10 3.250ACUVIX 1000 INOX 1000 ACUVIX1000-10 4.220ACUVIX 1500 INOX 1500 ACUVIX1500-10 6.200ACUVIX 2000 INOX 2000 ACUVIX2000-10 7.700ACUVIX 2500 INOX 2500 ACUVIX2500-10 9.100ACUVIX 3000 INOX 3000 ACUVIX3000-10 10.800ACUVIX 4000 INOX 4000 ACUVIX4000-10 12.995ACUVIX 5000 INOX 5000 ACUVIX5000-10 16.500

Model capacity (liters) Exterior protection reference rp €

ACUVIX 100 INOX S 100

Flexible polyurethane with detachable PVC cover

ACUVIX0100-11 770ACUVIX 150 INOX S 150 ACUVIX0150-11 1.040ACUVIX 200 INOX S 200 ACUVIX0200-11 1.110ACUVIX 300 INOX S 300 ACUVIX0300-11 1.550ACUVIX 500 INOX S 500 ACUVIX0500-11 3.100ACUVIX 750 INOX S 750 ACUVIX0750-11 3.650ACUVIX 1000 INOX S 1000 ACUVIX1000-11 4.750ACUVIX 1500 INOX S 1500 ACUVIX1500-11 6.900ACUVIX 2000 INOX S 2000 ACUVIX2000-11 7.995ACUVIX 2500 INOX S 2500 ACUVIX2500-11 9.450ACUVIX 3000 INOX S 3000 ACUVIX3000-11 11.500ACUVIX 4000 INOX S 4000 ACUVIX4000-11 14.850ACUVIX 5000 INOX S 5000 ACUVIX5000-11 17.800

characteristics 100 l 150 l 200 l 300 l 500 l 750 l 1000 l 1500 l 2000 l 2500 l 3000 l 4000 l 5000 l

Exchange surface 0,38 0,48 0,64 1,32 1,68 2,72 3,48 4,05 4,86 5,67 6,48 7,3 8,11Diameter (D mm) 480 580 580 580 800 800 930 1140 1300 1400 1500 1600 1750

Height (A mm) 1010 980 1280 1780 1710 1920 2000 2055 2100 2155 2230 2890 2935Weight (Kg) 50 60 75 115 135 180 200 245 300 375 450 600 725

Max. working pressure (bar) 8Max. temperature (ºC) 90

Vertical storage tanks, AISI 316 stainless steel, 5-year warranty. AISI 316 stainless steel coils with large exchange surface.

STAINLESS STEELstorage tanks

STORAGE TANKS FOR DHW

Direct stainless steel storage tanks

stainless steel storage tanks with fixed coil

new

Page 41: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 41

STO

RA

GE

TAN

KS

AC

UM

ULA

DO

RES

Model capacity (liters) Exterior protection reference rp €

ACUVIN 100 INER 100

Flexible polyurethane with detachable PVC cover

ACUVIN0100-10 485ACUVIN 150 INER 150 ACUVIN0150-10 595ACUVIN 200 INER 200 ACUVIN0200-10 635ACUVIN 300 INER 300 ACUVIN0300-10 705ACUVIN 500 INER 500 ACUVIN0500-10 930ACUVIN 800 INER 800 ACUVIN0750-10 1.230ACUVIN 1000 INER 1000 ACUVIN1000-10 1.395ACUVIN 1500 INER 1500 ACUVIN1500-10 1.750ACUVIN 2000 INER 2000 ACUVIN2000-10 2.095ACUVIN 2500 INER 2500 ACUVIN2500-10 2.650ACUVIN 3000 INER 3000 ACUVIN3000-10 2.995ACUVIN 4000 INER 4000 ACUVIN4000-10 4.350ACUVIN 5000 INER 5000 ACUVIN5000-10 4.900

Model capacity (liters) Exterior protection reference rp €

ACUVIN 100 INER S 100

Flexible polyurethane with detachable PVC cover

ACUVIN0100-11 700ACUVIN 150 INER S 150 ACUVIN0150-11 770ACUVIN 200 INER S 200 ACUVIN0200-11 810ACUVIN 300 INER S 300 ACUVIN0300-11 890ACUVIN 500 INER S 500 ACUVIN0500-11 1.150ACUVIN 800 INER S 850 ACUVIN0750-11 1.695ACUVIN 1000 INER S 1000 ACUVIN1000-11 1.875ACUVIN 1500 INER S 1500 ACUVIN1500-11 2.300ACUVIN 2000 INER S 2000 ACUVIN2000-11 2.900ACUVIN 2500 INER S 2500 ACUVIN2500-11 3.300ACUVIN 3000 INER S 3000 ACUVIN3000-11 3.950ACUVIN 4000 INER S 4000 ACUVIN4000-11 5.150ACUVIN 5000 INER S 5000 ACUVIN5000-11 5.700

characteristics 100 l 150 l 200 l 300 l 500 l 850 l 1000 l 1500 l 2000 l 2500 l 3000 l 4000 l 5000 l

Exchange surface 0,38 0,48 0,64 1,32 1,68 3,1 3,48 4,05 4,86 5,67 6,48 7,3 8,11Diameter (D mm) 480 580 580 580 700 930 930 1150 1300 1400 1500 1700 1850

Height (A mm) 1050 1000 1300 1800 1950 1750 2000 2100 2150 2255 2330 2350 2450Weight (Kg) 50 60 75 115 135 180 200 245 300 375 450 600 725

Max. working pressure (bar) 6Max. temperature (ºC) 90

Vertical buffer storage tanks, carbon steel specifically for heating systems, 5-year warranty. Carbon steelcoils with large exchange surface.

storage tanks

BUFFERSTORAGE TANKS

Direct buffer storage tanks

Buffer storage tanks with fixed coil

new

Page 42: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

42

nr collectors Description reference rp €

From 5 to 20 Insulation for models INTERC 01 and 02 INTERC-11 245From 21 to 35 Insulation for models INTERC 03 INTERC-12 305From 36 to 60 Insulation for models INTERC 04 and 05 INTERC-13 305From 61 to 90 Insulation for models INTERC 06 and 07 INTERC-14 305From 91 to 100 Insulation for models INTERC 08 INTERC-15 400

Brazed-plate heat exchangers for DhW

nr collectors power inlets reference rp €

From 5 to 12 From 6 to 15 kW 3/4” INTERC-01 170From 13 to 20 From 16 to 24 kW 3/4” INTERC-02 230From 21 to 35 From 25 to 42 kW 1” INTERC-03 295From 36 to 50 From 43 to 60 kW 1” INTERC-04 345From 51 to 60 From 61 to72 kW 1” INTERC-05 595From 61 to 70 From 73 to 84 kW 1” INTERC-06 665From 71 to 90 From 85 to 108 kW 1” INTERC-07 735From 91 to 100 From 109 to 120 kW 1 1/4” INTERC-08 850

heat exchangers

insulations

ACCESSORIESSOLAR THERMAL ENERGY accessories

** Design conditions: - Primary circuit liquid temperature = 60ºC - Secondary circuit liquid outlet temperature = 50ºC - Primary circuit working liquid = propylenglycol 30 ºC - Secondary circuit working liquid = water

*** Contact technical department for models of a higher power

NETWORKWATER

Pump secondary

EXPANSIONVESSEL

FILLINGEMPTYING

Pump primary

Heat exchanger

Page 43: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 43

References BOMBAD-P01 BOMBAD-P02 BOMBAD-P03 BOMBAD-P04 BOMBAD-P05 BOMBAD-P06 BOMBAD-P07

Up to: 15 collectors 20 collectors 30 collectors 40 collectors 50 collectors 80 collectors 100 collectors

RP (€) 270 420 665 740 875 1.385 1.650

Nr collectors Q(m3/h) Hmax (m) Hmax (m) Hmax (m) Hmax (m) Hmax (m) Hmax (m) Hmax (m)

5 0,48 5,7

10 0,96 4,8 6

15 1,44 4 5,6

20 1,92 3,1 4,7 6,2

25 2,40 2,4 4 6,1 8

30 2,88 3,2 5,8 7,7 9,6

40 3,84 4,8 6,6 8,4 11,9

50 4,80 4 5,5 7,1 11,1

60 5,76 4,5 6 10,3 12

70 6,72 4,8 9,7 11,7

80 7,68 9,1 11,3

90 8,64 8,5 10,8

100 9,60 7,8 10,1

References BOMBAD-S01 BOMBAD-S02 BOMBAD-S03 BOMBAD-S04 BOMBAD-S05 BOMBAD-S06

Up to: 5 collectors 15 collectors 30 collectors 50 collectors 70 collectors 100 collectors

RP (€) 375 390 540 885 890 940

Nr collectors Q(m3/h) Hmax (m) Hmax (m) Hmax (m) Hmax (m) Hmax (m) Hmax (m)

5 0,48 4 5,4

10 0,96 3,6 4,9

15 1,44 3,1 4,4 7

20 1,92 3,1 3,7 6,7

25 2,40 3,1 6,4

30 2,88 6 8,1

40 3,84 5,2 8 9,9

50 4,80 4 7,8 9,7

60 5,76 7,5 9,5 12,6

70 6,72 7,1 9,2 12,1

80 7,68 6,9 8,7 11,6

90 8,64 8 11

100 9,60 7,3 10,5

circulation pumps

Pumps from P01 to P05 include their connection joints. Pumps from P06 to P07 include fl anges

for primary circuits

for secondary circuits

AC

CES

SO

RIE

S

ACCESSORIESSOLAR THERMAL ENERGY accessories

Pumps from S01 to S03 include their connection joints. Pumps from S04 tp S06 include their fl anges.

Page 44: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

44

1 way without controller 1 way with controller

2 ways with controller 2 ways drainback

*Maximum pressure loss in hydraulic circuit 6.5 m.w.p.

*Maximum pressure loss in hydraulic circuit 6.5 m.w.p.

for primary circuits up to 8 collectors

pump units

Description flowmeter pump inlets reference rp €

Solar station 1W - without controller 2-12 l/min Wilo Yonos for 25/7,0 3/4” M ESTASOL-01 355Solar station 1W - con centralita STDC 2-12 l/min Wilo Yonos for 25/7,0 3/4” M ESTASOL-02 565Solar station 2 W - with controller MTDC 2-12 l/min Grundfos UPM3 solar 7,5 3/4” M ESTASOL-03 705

- Circulating pump- 1 fl ow regulator (2 - 12 l/min || 8 - 38 l/min).- 1 thermometer (impulsion)- 1 safety valve (6 bar)- 1 fi lling valve and 1 emptying valve- 1 manomether- Thermal insulation

- Circulating pump (drainback)- 1 fl ow regulator- 2 thermometers (impulsion and return)- 1 safety valve (6 bar)- Without retention valve- 1 fi lling valve and 1 emptying valve- 1 manomether- Thermal insulation- Controller MTDC-E

ACCESSORIESSOLAR THERMAL ENERGY accessories

for primary circuits up to 20 collectorsDescription flowmeter pump inlets reference rp €

Solar station 1 W - without controller 8-38 l/min Wilo Yonos for 25/7,5 1” M ESTASOL-04 515Solar station 1 W - with controller MTDC 8-38 l/min Wilo Yonos for 25/7,5 1” M ESTASOL-05 745Solar station 2 W - without controller 8-38 l/min Wilo Yonos for 25/7,5 1” M ESTASOL-06 585Solar station 2 W - with controller MTDC 8-38 l/min Wilo Yonos for 25/7,5 1” M ESTASOL-07 920

for primary circuits up to 8 collectors. special DrainbackDescription flowmeter pump inlets reference rp €

Solar station 2 W - with controller MTDC 2-12 l/min Wilo Yonos for 25/7,5 PWM 1” M ESTASOL-08 875Solar station 2 W - with controller MTDC 2-12 l/min Wilo Yonos for 15/13 PWM 1” M ESTASOL-09 930

- Circulating pump- 1 fl ow regulator (8 - 38 l/min || 8 - 38 l/min).- 1 thermometer (impulsion)- 1 safety valve (6 bar)- 1 fi lling valve and 1 emptying valve- 1 manomether- Thermal insulation- Controller STDC

- Circulating pump- 1 fl ow regulator- 2 thermometers (impulsion and return)- 1 safety valve (6 bar)- 1 fi lling valve and 1 emptying valve- 1 manomether- Thermal insulation- Controller MTDC-E

Page 45: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 45

* These controllers are delivered without probes

AC

CES

SO

RIE

S

shell and tube heat exchangers for swimming pool

nr collectors Description reference rp €

From 1 to 5 Power: solar from 1 to 6 kW // Heater 25 kW INTERC-41 475From 6 to 15 Power: solar from 7 to 18 kW // Heater 45 kW INTERC-42 555From 16 to 30 Power: solar from 19 to 36 kW // Heater 85 kW INTERC-43 810From 30 to 35 Power: solar from 37 to 42 kW // Heater 105 kW INTERC-44 1.290

nr collectors Description reference rp €

From 1 to 5 Power: solar from 1 to 6 kW // Heater 25 kW INTERC-51 785From 6 to 15 Power: solar from 7 to 18 kW // Heater 45 kW INTERC-52 900From 16 to 30 Power: solar from 19 to 36 kW // Heater 85 kW INTERC-53 1.420From 30 to 35 Power: solar from 37 to 42 kW // Heater 105 kW INTERC-54 1.915

stainless steel heat exchangers for swimming pool of non salted water

titanium heat exchanger for salty swimming pools

control systems

Description reference rp €

Termicol STDC with 2 probes (1 mechanic relay, 1 PVM connection, 3 inlets PT1000) CENTRALI-15 210Termicol MTDC with 3 probes (2 mechanic relays, 1 PVM connection, 4 inlets PT1000) CENTRALI-16 295Termicol LTDC with 4 probes (3 mechanic relays, 2 PVM connection, 6 inlets PT1000) CENTRALI-17 455Termicol XTDC without probes (6 mechanic relays, 2 PVM connection, 8 inlets PT1000) CENTRALI-18 870Termipool Easy Control (3 outlets relay 10 Amps) PISC-067 275Contact temperature probe PT1000 PISC-063 27Temperature probe PT1000 SONDA-01 17

ACCESSORIESSOLAR THERMAL ENERGY accesories

* 3 inlets for PT1000 temperature sensors* 1 outlet relay 230 V AC (on/off)* 1 outlet PWM (control of speed for high efficiency pumps)* 9 preconfigured hydraulics options

* 6 inlets for PT1000 temperature sensors* 2 inlets VFS/RPS Directsensor to measure flow* 2 outlets relay 230 V AC (on/off)* 2 outlets PWM (control of speed for high efficiency pumps)* 42 preconfigured hydraulics options

* 4 inlets for PT1000 temperature sensors* 2 outlets relay 230 V AC (on/off)* 1 outlet PWM (control of speed for high efficiency pumps)* 25 preconfigured hydraulics options

* 8 inlets for PT1000 temperature sensors* 2 inlets for Grundfos VFS/RPS sensor* 1 inlet for RC21 room sensor* 2 outlets PWM (control of speed for high efficiency pumps)* 2 connections for flow control* 4 outlets relay 230 V AC (on/off)* Micro SD Memory Card Slot* Ethernet connection (in model V2)* 48 preconfigured hydraulics options

stDc-V3 MtDc-V3

ltDc-V3 XtDc-V1

controllers

* Conditions of solar power: Input temperature 1º = 50ºC* Conditions of solar power: Input temperature 1º = 90ºC* Maximum flow per shell 15 m3/h

85 kW

105 kW

45 kW

25 kW

new

Page 46: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

46

Dinamic heat sinks Connections

ACCESSORIESSOLAR THERMAL ENERGY accessories

Dinamic heat sinks Models

nº collectors Description reference rp €

From 1 to 4 T25From 1 to 5 T20

Heat sink 8 kW DISIPADO-01 505

From 5 to 9 T25From 6 to 12 T20

Heat sink 18 kW DISIPADO-02 565

From 10 to 13 T25From 13 to 16 T20

Heat sink 24 kW DISIPADO-03 675

From 14 to 21 T25From 17 to 26 T20

Heat sink 40 kW DISIPADO-04 1.035

From 22 to 27 T25From 27 to 34 T20

Heat sink 52 kW DISIPADO-05 1.145

From 28 to 32 T25From 35 to 40 T20

Heat sink 61 kW DISIPADO-06 1.385

From 33 to 40 T25From 41 to 50 T20

Heat sink 76 kW DISIPADO-07 1.525

From 41 to 50 T25From 51 to 70 T20

Heat sink 106 kW * DISIPADO-08 2.250

From 51 to 80 T25From 71 to 100 T20

Heat sink 152 kW * DISIPADO-09 2.620

From 81 to 100 T25From 101 to 125 T20

Heat sink 190 kW * DISIPADO-10 2.870

air sinks

* Heat sinks of 106 kW, 152 kW and 190 kW are triple phase, the rest are single phase

** Design conditions: - Intake liquid temperature = 90ºC - Intake aire temperature = 35ºC - Working liquid propylenglycol 30%

*** Contact technical department for models of a higher power

Page 47: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 47

Thermostatic valve T 90ºC

Thermostatic valve T 70 ºC

Passive heat sink

Passive heat sink

static heat sinks Models

static heat sinks Connections

AC

CES

SO

RIE

S

ACCESSORIESSOLAR THERMAL ENERGY accessories

nº collectors Description reference rp €

1 T25 and 1 T20 Static heat sink 1.500 W DISIPEF-01 5352 T20 Static heat sink 2.500 W DISIPEF-02 625

2 T25 and 3 T20 Static heat sink 3.500 W DISIPEF-03 7103 T25 and 4 T20 Static heat sink 4.500 W DISIPEF-04 8654 T25 and 5 T20 Static heat sink 5.500 W DISIPEF-05 9005 T25 and 6 T20 Static heat sink 7.000 W DISIPEF-06 1.185

6 T25 Static heat sink 8.000 W DISIPEF-07 1.295

nº collectors Description reference rp €

1 T20 and 1 T25 Static heat sink 1.250 W DISIPET-01 4252 T20 Static heat sink 1.750 W DISIPET-02 4602 T25 Static heat sink 2.500 W DISIPET-03 545

* Design conditions for heat sinks placed in horizontal position; wind speed 0 m/s; ∆ t = 70 oC; ramp 5%.

Description reference rp €

Connection for collectors array (statis heat sinks) BATCAPT-05 122

Description reference rp €

Connection for thermosyphonic kits (static heat sinks) BATCAPT-06 25

for collector arrays

for thermosyphonic kits

Thermostatic valve

Pasive heatsink

Networkwater

Expansionvessel

Emptying

* Design conditions for heat sinks placed in horizontal position; wind speed 0 m/s; ∆ t = 70 oC; ramp 5%.

Filling

Page 48: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

48

heat transfer fl uid

expansion systems

Description reference rp €

Antifreeze “Fluidosol” concentrated 2 l ANTICONG-05 15Antifreeze “Fluidosol” concentrated 10 l ANTICONG-01 75Antifreeze “Fluidosol” concentrated 25 l ANTICONG-02 180Antifreeze “Fluidosol” concentrated 210 l ANTICONG-04 1.470Antifreeze “Fluidosol” concentrated 1000 l ANTICONG-06 6.875

Description reference rp €

Expansion vessel 8 L VASOEXPA-01 56Expansion vessel 12 L VASOEXPA-02 57Expansion vessel 18 L VASOEXPA-03 60Expansion vessel 24 L VASOEXPA-04 70Expansion vessel 35 L VASOEXPA-05 225Expansion vessel 50 L VASOEXPA-06 260Expansion vessel 80 L VASOEXPA-07 325Expansion vessel 100 L VASOEXPA-08 430Expansion vessel 220 L VASOEXPA-09 835Expansion vessel 350 L VASOEXPA-10 1.040Expansion vessel 500 L VASOEXPA-11 1.460Expansion vessel 700 L VASOEXPA-12 2.450

Expansion vessel connection set SETESTSO-01 67

insulated stainless steel pipes

Description reference rp €

Pre-insulated stainless steel double pipe connectionDN 16. Length 50 meters. Threaded joint set.

CONX - 21 825

Pre-insulated stainless steel double pipe connectionDN 16. Length 25 meters. Threaded joint set.

CONX - 13 700

Pre-insulated stainless steel double pipe connection DN 16Length 50 meters. Threaded joint set. CONX - 14 1.400

Pre-insulated stainless steel double pipe connection DN 20Length 50 meters. Threaded joint set. CONX - 17 1.800

for primary circuits

for primary circuits

Double tube with cable

* Contact us for availability and prices for other dimensions.

ACCESSORIESSOLAR THERMAL ENERGY accessories

Motorized 3 way valves

Description reference rp €

3 ways motorized valve 1/2’’ (Tmax 160 ºC) VALV3VIA-01 165

3 ways motorized valve 3/4’’ (Tmax 160 ºC) VALV3VIA-02 1653 ways motorized valve 1’’ (Tmax 160 ºC) VALV3VIA-03 165

3 ways motorized valve 1 1/4¨ (Tmax 150 ºC) VALV3VIA-04 6603 ways motorized valve 1 1/2¨ (Tmax 150 ºC) VALV3VIA-05 695

3 ways motorized valve 2¨ (Tmax 150 ºC) VALV3VIA-06 815

for primary circuits

Page 49: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 49

AC

CES

SO

RIE

S

ACCESSORIESSOLAR THERMAL ENERGY accessories

filling and maintenance system for solar energy

nº collectors Description reference rp €

From 6 to 15 Digital fi lling and draining systems 120L SLLVD-01 3.380From 16 to 25 Digital fi lling and draining systems 200L SLLVD-02 3.470From 26 to 35 Digital fi lling and draining systems 300L SLLVD-03 3.660From 36 to 50 Digital fi lling and draining systems 500L SLLVD-04 4.440From 51 to 120 Digital fi lling and draining systems 1000L SLLVD-05 4.700

nº collectors Description reference rp €

From 1 to 6 Electronic fi lling and draining systems 50L SLLVE-01 2.280From 7 to 15 Electronic fi lling and draining systems 120L SLLVE-02 2.430From 16 to 25 Electronic fi lling and draining systems 200L SLLVE-03 2.570From 26 to 35 Electronic fi lling and draining systems 300L SLLVE-04 2.780From 36 to 50 Electronic fi lling and draining systems 500L SLLVE-05 3.170From 51 to 120 Electronic fi lling and draining systems 1000L SLLVE-06 3.510

With 30-litre drum and fi lter with viewer

Digital equipment

electronic equipment

filling and draining systems

protection measurement systems

Description reference rp €

Refractometer REFRAC-01 130

pH strips (100 unit) TIRPH-01 40

Description reference rp €

With 30-litre drum and fi lter with viewer SLLMA-01 915

antifreeze

     

Telescopic handle Graduated drum 90° hose fi tting

collectors temperature

control system

Pressure control system

DHW storage

tanks

solar controller

Sola

r col

lect

ors

Page 50: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

50

‘HEATING YOUR SWIMMING POOL’Solar energy can be used to heat outdoor and indoor swimming pools and considerably extend the swimming season in an economical and environmentally-friendly manner.

PLASTIC SOLAR PANELS FOR SWIMMING POOLS

Dimensions

characteristics

Models and prices Model Description net area reference rp €

Termipool 1000 Plastic Solar panel for swimming pools 1,08 m2 PISC-001 129 Termipool 1001 Plastic Solar panel for swimming pools 1,05 m2 PISC-002 129 Termipool 1002 Plastic Solar panel for swimming pools 1,12 m2 PISC-003 129

Model termipool 1000 termipool 1001 termipool 1002Base 820 mm 820 mm 820 mm

Length 1320 mm 1280 mm 1360 mmNet Area 1,05 m2 1,05 m2 1,12 m2

technical general characteristics

Material High-molecular-weight polyethyleneFlow 150 to 250 lts.m2 /h

Reduced pressure loss Approx. 0.003 bar at 200l/h/m2

Weight Approx. Weight 6,9 kg/m2

Operating weight Capacity: Approx. 8 l/m2

Test pressure 4,5 bars a TNOperating pressure up to 1,2 bars at 40°CDegree of effi ciency up to Approx. 80 % (capacity up to 0,8 kWh/m2)

Average value 0,65 kWh/m2

Temperature resistance - 50ºC to + 115ºC

termipool 1000* termipool 1001* termipool 1002* connection between panels

SWIMMING POOLS SOLAR PANELS

*5-years warranty.

Page 51: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 51

This method provides an approximate calculation for guidance purposes. Many factors go into calculating the heating required for a swimming pool; with this method, it is possible to approximately calculate the number of panels required.

Contact Termicol’s technical department for a more detailed study.

www.termicol.es | 51

Method for approximately calculating the number of Termipool collectors required.

1º select zone factor:

2º select wind factor:

4º calculation of number of Termipool units:

FZ = 0,75 north area

FZ = 0,60 center area

FZ = 0,45 south area

FV = 1 light v < 16 km/h

FV = 1,3 Medium 17 < v < 25 km/h

FV = 1,55 strong v > 26 km/h

FP = 0,75 with thermal blanket

FP = 1 without thermal blanket

Nº Termipool= m2 pool x FZ x FV x Fp

3º select protection factor:

SWIMMING POOLS CALCULATION pools

PO

OLS

Page 52: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

52

Operation with a purification pump via a motorized three-way valve with differential temperature regulation.

This type of connection can be selected as a general rule provided that the panels are not mounted more than 6 meters above the surface of the water. In the purification system’s pressure line, a motorized three-way valve is installed. The differential temperature regulation enables the valve to be changed when the operating temperature is higher than the temperature of the swimming pool water. The flow from the filter is then pumped through the panels and the heated water flows back through a T-shaped fitting to the filter circuit.

Operation with own pump and differential temperature regulation separate from the filter circuit.

This type is used if the position of the filter is difficult to access. By means of a submerged pipe, the swimming pool water is sucked out, pumped through the panels and returned as heated water. The differential temperature regulation also ensures that the pump only functions when energy is gained. If the pump is mounted above water level and at a transportation height of over 5 m, it is necessary to install a check valve.

Different types of connection for swimming pool solar heating systems

25 mm clamp set for flat roofs 0º tiled roof assembly set 40 mm clamp

nº Description reference termicol rp €

1 Stainless steel coupling and clamps for connections ø40 PISC-011 62 Stainless steel coupling and clamps for connections ø25 PISC-012 6- Flat roof (0°) assembly set 0º PISC-021 205 - Tiled roof assembly set PISC-022 275 3 Panel field and pipe connection set Ø40 PISC-031 20 4 Pipe purging set ø40 PISC-034 30 5 Pipe draining set ø40 PISC-037 10 6 EPDM check valve ø40 PISC-041 20 7 PE/EPDM ball valve ø40 PISC-043 15 8 Swimming pool circuit connection set ø40-ø50 PISC-051 10 9 Thermowell set for swimming pool sensor ø50 PISC-054 20 10 Termipool Easy control PISC-061 275 11 Swimming pool pump 1/4 HP for H=7m A=7m3/h PISC-083 320 12 3-way manual valve PISC-098 80

SWIMMING POOLS INSTALLATION ACCESSORIES pools

Page 53: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 53

10 termipool 1002panels area: 11,2 m2

Version 1. 6 termipool 1000 and 3 termipool 1001panels area: 9,63 m2

necessary accessories for connecting the fi eld of collectorsVersion accessories

Version 1

20 stainless steel couplings and clamps for Ø40 connections

1 panel fi eld and Ø40 pipe connection set1 roof assembly set

Version 2

6 stainless steel couplings and clamps for Ø40 connections12 stainless steel couplings and clamps for Ø25 connections

1 panel fi eld and Ø40 pipe connection set1 roof assembly set

Version 3

12 stainless steel couplings and clamps for Ø40 connections12 stainless steel couplings and clamps for Ø25 connections

1 panel fi eld and Ø40 pipe connection set1 roof assembly set

136 cm

847 cm

82 cm

3 cm

82 cm

3 cm

82 cm

3 cm

82 cm

3 cm

82 cm

3 cm

82 cm

3 cm

82 cm

3 cm

82 cm

3 cm

82 cm

3 cm

82 cm

3 cm

132 cm

507 cm

267 cm

132 cm

3 cm

Version 2.

12 termipool 1000 panels area: 12,96 m2

Version 3.

82 cm 3 cm 82 cm 3 cm 82 cm 3 cm 82 cm 3 cm 82 cm 3 cm 82 cm

The three models enable multiple confi gurations to be created to suit the area in which the collection fi eld is located.

SWIMMING POOLSINSTALLATION AND CONNECTION pools

PO

OLS

398 cm

132 cm

3 cm

128 cm

3 cm

132 cm

3 cm

82 cm 3 cm 3 cm82 cm

252 cm

82 cm

Coupling and clamp

Connection set between collectors fi eld and pipe ø 40 (contains inlet and outlet)

Page 54: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

54

pumping systems

Swimming pool temperatureTermipools temperature

Selection of temperature diferential bet-ween Termipools and swimming pool to switch on the pump

Selection of maximum pool tempe-rature

Mode selection

AUTO (start and stop by diferential and maximum)

ON (manual start)

OFF (manual stop)

SWIMMING POOLSCONTROL AND PUMP pools

control system

Description reference rp €

Termipool Easy Control3 outlets of relay of 10 Amps

PISC-067 275

References PISC-083 PISC-084 PISC-085 PISC-086

Nº Termipool Flow Hmax (m.w.p.) Hmax (m.w.p.) Hmax (m.w.p.) Hmax (m.w.p.)

10 2 m3/h 11 12 13 15

15 3 m3/h 10.5 11.5 12.7 14.5

20 4 m3/h 10 11 12.5 14

25 5 m3/h 9 10.5 12 13.5

30 6 m3/h 8.5 10 11.5 13

35 7 m3/h 7 9 11 12.5

40 8 m3/h 8.5 10.5 12

45 9 m3/h 7.5 9 11

50 10 m3/h 8.5 10.5

Power (kW - CV) 0,18 kW - 1/4 CV 0,25 kW - 1/3 CV 0,40 kW - 1/2 CV 0,55 kW - 3/4 CV

RP (€) 320 345 365 385

Page 55: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 55

kits for pool heating (complete)

kits for pool heating (without pump)

PO

OLS

SWIMMING POOLSSWIMMING POOL HEATING KITS pools

list of Materials units

1 Collectors/connections/fi xations N

2 Termipool EASY Control 1

3 Pool Solar pump 1

4 Pipe go & return D40 ...

5 Air vent set 1

6 Emptying set 1

7 Antireturn valve 1

8 Antireturn valve 1

9 Ball valve (brake) 2

10 Inserting housing for pool probe 2

11 Inserting housing for pool probe 1

pool area nr termipool roof area type terrace reference rp €

18 m2 12 Termipool 1000 x = 5,2 ; y = 2,7Flat terrace PISC-K001 2.645

Tile roof PISC-K051 2.715

24 m2 8 Termipool 10008 Termipool 1001

x = 3,5 ; y = 5,3Flat terrace PISC-K002 3.205

Tile roof PISC-K052 3.275

32 m2 14 Termipool 10007 Termipool 1001

x = 6,1 ; y = 4Flat terrace PISC-K003 3.910

Tile roof PISC-K053 3.980

pool area nr termipool roof area type terrace reference rp €

18 m2 12 Termipool 1000 x = 5,2 ; y = 2,7Flat terrace PISC-K101 2.320

Tiled roof PISC-K151 2.390

24 m2 8 Termipool 10008 Termipool 1001

x = 3,5 ; y = 5,3Flat terrace PISC-K102 2.885

Tiled roof PISC-K152 2.955

32 m2 14 Termipool 10007 Termipool 1001

x = 6,1 ; y = 4Flat terrace PISC-K103 3.590

Tiled roof PISC-K153 3.660

* Contact us for a different roof confi guration.** Contact technical department for a customized technical study.

Page 56: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

‘HARNESSING THE POWER OF THE SUN’

Every 15 minutes, the surface of the Earth receives enough sunlight to meet the energy needs of the entire world for a whole year.

· Photovoltaic systems do not require sophisticated maintenance. Solar modules also have a proven useful life of more than 25 years.

· As the technology is modular, photovoltaic installations have the fl exibility to adapt to various power requirements and can be expanded according to future needs.

· It helps to conserve resources. Our natural resources are scarce; oil, gas and uranium are becoming exhausted. Solar energy however is virtually unlimited and available in all corners of the world.

Solar energy is the most abundant source of energy available on our planet. Every 15 minutes, the surface of the Earth receives enough sunlight to meet the energy needs of the entire world for a whole year. Harnessing the power of the sun has proven to be a reliable method to produce energy and, today, entire countries obtain a signifi cant portion of their energy from solar panels.

Photovoltaic solar energy is one of the most environmentally-friendly sources of energy; it is clean, does not emit harmful gases and is currently one of the main weapons in the fi ght against the serious environmental problems facing the planet.

This energy enables electricity to be produced through the incidence of solar radiation on solar modules. The direct current that photovoltaic panels provide can be converted into alternating current by an inverter, which enables it to be stored for autonomous consumption or transformed into conventional electricity for introduction into the grid.

There are many reasons to choose solar energy:

· It does not pollute and it is a clean way to generate electricity: renewable, economical and environmentally-friendly.

· It is an energy that is within everyone’s reach; it can generate electricity through installations on roofs, pergolas, or any available structure.

- 240 and 290 W modules.- Self-consumption kits.

WHY CHOOSE PHOTOVOLTAIC SOLAR ENERGY?

WHAT DOES TERMICOL OFFER?

PHOTOVOLTAIC SOLAR ENERGY PRESENTATION photovoltaic

56

Page 57: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 57www.termicol.es | 57

PH

OTO

VOLT

AIC

Highly-effi cient module with stable output power, based on an innovative process technology.

Exceptional electrical performance in conditions of high temperature or low irradiance.

Easy installation due to an innovative engineering design.

Rigorous quality control that meets the highest international standards.

Warranty: 10 years for manufacturing defects and 25 years for performance.

PHOTOVOLTAIC SOLAR ENERGYSOLAR MODULES photovoltaic

solar Modulesa 290p Gse anD a240p Gse

PH

OTO

VOLT

AIC

electrical characteristics

Maximum Power (Pmax) 240 W

Maximum Power Tension (VMP ) 30.88 V

Maximum Current Power (IMP) 7.80 A

Open Circuit Tension (VOP) 37.76 V

Shortcut current (ISCC ) 8.21 A

Module effi ciency (%) 14.73

Power Tolerance (W) 0/+5

Maximum fuses Serie (A) 15

System maximum Tension DC 1000 V (IEC) / DC 600 V (UL)

Regular working temperature of the cell (ºC) (TONC ) 46 3

electrical characteristics

Maximum Power (Pmax) 290 W

Maximum Power Tension (VMP ) 35.84 V

Maximum Current Power (IMP ) 8.11 A

Open Circuit Tension (VOP ) 44.51 V

Shortcut current (ISCC ) 8.55 A

Module effi ciency (%) 14.89

Power Tolerance (W) 0/+5

Maximum fuses Serie (A) 15

System maximum Tension DC 1000 V (IEC) / DC 600 V (UL)

Regular working temperature of the cell (ºC) (TONC ) 46 3

MoDule a240p Gse

MoDule a290p Gse

www.termicol.es | 57

Page 58: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

58

Self-consumption is a method of saving energy in which the electricity production of the photovoltaic system coincides with the household’s power consumption, thus precluding the need to consume this energy from the power grid.

The main benefit of self-consumption is energy savings. Part of the energy consumed is produced with the resultant savings on electricity bills. If the continuous rise in electricity prices is also taken into account, producing energy in this way can pay for itself in very little time.

A second benefit of self-consumption is that energy losses in the grid are avoided as the electricity does not have to travel long distances. The current model of centralized generation results in 10% of electricity being lost during transmission and distribution.

Another benefit is that electricity is produced with clean technologies, thereby reducing the use of polluting fossil fuels (oil) and dependence on its consumption. Photovoltaic energy is the most suitable way to generate electricity for self-consumption in households.

Its modular installation enables it to be expanded very easily.

What is self-consumption?

Benefits

PHOTOVOLTAIC SOLAR ENERGY SELF CONSUMPTION self

consumption

58

Page 59: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 59

PH

OTO

VOLT

AIC

self consumption

As a typical household of 4 people consumes an average of about 3,500 kWh a year, one 240 Wp photovoltaic module would produce about 10% of the energy consumed.

how much energy does it produce?

PHOTOVOLTAIC SOLAR ENERGY SELF CONSUMPTION

Description potency reference rp €

kit nº1 Self consumption 325 kWh/year 240 Wp PVAUT-01 913kit nº2 Self consumption 650 kWh/year 480 Wp PVAUT-02 1.705kit nº3 Self consumption 975 kWh/year 720 Wp PVAUT-03 2.526kit nº4 Self consumption 1.300 kWh/year 960 Wp PVAUT-04 3.404kit nº5 Self consumption 1.625 kWh/year 1.200 Wp PVAUT-05 4.240kit nº6 Self consumption 1.950 kWh/year 1.440 Wp PVAUT-06 5.075

Note: The complete kit includes: solar fi eld, micro inverter, coplanar structure (for pitched roofs without anchorage) and fi ttings. An energy meter, the structure for other types of roof and the anchorages are optional. Energy performance data is approximate and depends on the geographic location of the installation.

Module Structure Micro inverter Fittings

Models and prices

kit components

Page 60: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

‘THE MAIN REASON IS ECONOMIC’Thermal energy is present in the air that surrounds us, even at low temperatures, and air heat pumps allows us to take advantage of this energy.

WHY CHOOSE AIR HEAT PUMPS?The main reason is economic. With an air/water heat pump, it is cheaper to heat water than with a traditional system. You can reduce water heating costs by up to 75%, although the exact fi gure depends mainly on where you live. With energy prices always on the rise, it is no surprise that these systems have gained in popularity in recent years and will continue to do so in the future.

The second reason for choosing an air/water heat pump is that it is environmentally-friendly. Thermal energy is present in the air that surrounds us, even at low temperatures, and aerothermic allows us to take advantage of this energy to heat water in a tank. To do so, the system uses a CFC-free gas, which contributes to the protection of the ozone layer. This energy from the outside air is used to heat hot water, producing far fewer CO2 emissions than any traditional system using fossil fuels.

The third reason is that the installation of the MONOBLOC system is very simple, as it is similar to an electric boiler of equal capacity, and one unit can meet 100% of domestic hot water needs. To achieve the best performance, it is advisable to take the air from a ventilated, unheated interior space, such as a ventilated garage, partially-covered verandah, attic or from the extraction of air from ventilation.

Another reason for choosing an air/water heat pump to provide clean domestic hot water in an economical and easy-to-maintain manner is that it is not necessary to install a natural gas supply, gas fl ues or chimneys, thereby reducing household CO2 emissions.

AIR HEAT PUMPSPRESENTATION

60

air heat pumps

Air heat pumps enables thermal energy from the airto be transferred to heating and hot water circuits.

Page 61: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 61

The monoblock-type heat pump for DHW has an integrated design. This system only needs to be connected to the cold water inlet and hot water outlet pipes, making installation much simpler than other water heating products equipped with heat pumps. The product is very compact, small, simple to install and easy to use. As the heat pump uses heat from the air, its consumption of energy is minimal, so much so that 70% of the heat generated is free.

how does it work?

Benefi ts

Description reference rp €

Air heat pump 150 S AEROTER-01 2.080

Air heat pump 200 S AEROTER-02 2.230Air heat pump 300 S AEROTER-03 2.525

Models and prices

AIR HEAT PUMPSSTAINLESS STEEL MONOBLOC DHW SYSTEMS air heat pumps

· Coeffi cient of performance (COP) of up to 3.6; for each kWh of electricity consumed, 3.6 kWh of heat is produced

· Stainless steel storage tank (AISI 316).· Includes auxiliary coil for possible connection to a boiler or solar circuit.· Condenser coil external to the DHW tank (not in contact with the water).· Storage volume available in 150,200 and 300L· By default it includes an electrical backup of 1,5 kW.· Maximum hot water temperature: · Control panel with display.

characteristics technical data units aerothermics 150 s aerothermics 200 s aerothermics 300 s

Power supply V / Hz 220V~240V/50Hz

Refrigerant Type R410ACapacity L 150 200 300

Rated input power w 980 980 980Rated current A 4,5 4,5 4,5COP at 15ºC Û 3,6 3,6 3,6

Hot water output power L/h 72L/h 72L/h 72L/hAuxiliary electric resistance kW 1.5

Maximum hot water temperature ºC 65~70ºCMin/max ambient temperatures ºC -7~45ºCDimension of water connections " 3/4.

Noise dB(A) 48 48 48Weight (when empty) kg 85 90 105Net dimensions (DxH) mm Φ560*1530 Φ560*1725 Φ640*1850

Packaging dimensions (LxWxH) mm 630*630*1650 630*630*1845 710*710*1960

· Coeffi cient of performance (COP) of up to 3.6; for each kWh

AIR

HEA

T PU

MPS

Page 62: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

62

AIR HEAT PUMPSMONOBLOC EQUIPMENTS + SOLAR air heat pumps

Forced circulation units with all the required components for its installation.It is the highest effi ciency kit as it includes both solar and a high performance back up, an air heat pump

“An ideal combination of energies”

Components: 1. TERMICOL solar collectors2. Support structures3. Storage tank (monobloc air heat pump)4. Expansion vessel5. Accessories of valves and connections6. Pump and regulation system7. Antifreeze liquid

Mixed connection air heat pump + solar

air heat pump control system

Time

Heat pump working Electrical backup working (optional)

Temperature upper part of the tank Temperature at the lower part of the tank

Manual connection for electrical backup

Clock Programation

ON / OFF

Page 63: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 63

AIR

HEA

T PU

MPS

AIR HEAT PUMPSMONOBLOC EQUIPMENTS + SOLAR air heat pumps

“One kit one reference”

Forced circulation units with all the required components to install it.Easy and quick installation with pump and controll system included

collector steel captivation area (m2) flat roof reference tiled roof reference rp €

T20PS Steel

1,9

THPG1/150PS-01 THPG1/150PSCI-01 3.750T20PS Aluminum THPA1/150PS-01 THPA1/150PSCI-01 3.780T20US Steel THPG1/150US-01 THPG1/150USCI-01 3.870T20US Aluminum THPA1/150US-01 THPA1/150USCI-01 3.900

collector steel captivation area (m2) flat roof reference flat roof reference rp €

T25PS Steel

2,4

THPG1/200PS-01 THPG1/200PSCI-01 3.960T25PS Aluminum THPA1/200PS-01 THPA1/200PSCI-01 3.995T25US Steel THPG1/200US-01 THPG1/200USCI-01 4.075T25US Aluminum THPA1/200US-01 THPA1/200USCI-01 4.105

collector steel captivation area (m2) flat roof reference flat roof reference rp €

Two T20PS Steel

3,8

THPG2/300PS-01 THPG2/300PSCI-01 4.445Two T20PS Aluminum THPA2/300PS-01 THPA2/300PSCI-01 4.495Two T20US Steel THPG2/300US-01 THPG2/300USCI-01 4.685Two T20US Aluminum THPA2/300US-01 THPA2/300USCI-01 4.730

150 liters unit (1/2 users)

200 liters unit (3/4 users)

300 liters unit (5/6 users)

Example of nomenclature:

THPA2/300 US CIHeat Pump(Heat pump)

Tiledroof

Termicol Nr collectors

Aluminum support

Storage volume

Ultraselective collector

Page 64: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

BIOMASA

‘IT COMES DIRECTLY FROM NATURE’

Not only because of the energy savings it provides, but also because it is a totally ecological fuel which does not increase emissions of CO2 into the atmosphere.

WHY CHOOSE BIOMASS?When choosing a new heating system for the winter, it is 100% recommended to use biomass and, in particular, pellet stoves.

Not only because of the energy savings it provides, but also because it is a totally ecological fuel which does not increase emissions of CO2 into the atmosphere.

Biomass is a fuel that comes directly from nature, and the pellets, which are the most used fuel, consist of small cylinders of sawdust with a diameter of 5-6 mm and length of 10-25 mm. Pressing is carried out at high pressure and they are usually sold in sacks or bags, making them very easy to transport. They have to be stored in a dry place to prevent them from swelling and losing their properties, as moisture and water makes combustion slower and produces more smoke.

The pellets have a high calorifi c value, produce very little waste in the form of ash as a result of combustion, are easy to store and offer the possibility of application in stoves and boilers,

enabling them to function fully automatically. Their combustion also generates very low levels of CO2 emissions. They are a CO2-neutral fuel because their emissions are so small that they do not contribute to the greenhouse effect.

Energy savings obtained from pellets can be highly signifi cant as they have a much lower price compared to other fuels such as diesel, propane, butane or electricity.

Pellet stoves with forced-air circulation are equipped with a fan that constantly moves the hot air that the household produces. In this way, the heat spreads quickly around the room. The electronic control unit enables the power and fan speed to be controlled depending on requirements.

Pellet stoves operate fully automatically with a programmable timer and thermostat, i.e. with automated on and off functions. And the size of the tank and system determines how often the stove needs to be fi lled with pellets. Its design lends the living room a feeling of comfort and a pleasant and cozy atmosphere.

BIOMASSPRESENTATION

64

Pellet stoves produce warm air to heat the room where it is installed. They do not require a separate technical room and its installation is really easy. These pellet stoves generate heat by burning ¨pellet¨, which are small cilinders of pressed wood. They are of a high density and really compact. They do not require special conditions to maintain them and its high thermal power delivers high effi ciency and low amount of ash.

HOW DOES IT WORK?

Biomass

Page 65: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 65

Biomass

Models and prices

BIO

MA

SS

BIOMASSPELLET STOVES

Model Description colour reference rp €

Judit F65 Air 6,2 kWBurgundy PELLET-101

1.480 Old black PELLET-102Ivory PELLET-103

Judit F80 Air 8 kWBurgundy PELLET-111

1.710Old black PELLET-112Ivory PELLET-113

Judit F110 Air 11,2 kWBurgundy PELLET-121

1.905Old black PELLET-122Ivory PELLET-123

Carmen F125C Ducted air 12,5 kW Indian brown PELLET-134 3.295Jessica FL110C Air corridor 11,2 kW Ivory PELLET-144 3.160Bea Hidro F140 Hydro 14,3 kW Indian brown PELLET-154 3.960

· Particularly suitable for direct heating of rooms between 150 to 275 m3.· Supplementary smoke outlet on the right side (by default)· Clean fuel with no risk of explosion.· Forced-air circulation, providing rapid and uniform heating· Refi ned design and small dimensions.· Colour: Ivory, back old and burgundy, indian brown

advantages

new

Burgundy Old black Ivory Indian brown

Page 66: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

66

BIO

MA

SS

BIOMASSPELLET STOVES Biomass

air: models and characteristics

technical data units f65

Gross power kW 6.5Length mm 437Depth mm 460Height mm 790Weight kg 56

Potential volume for heating m3 148ø Smoke outlet mm 80

ø Air outlet mm 80Nominal electrical power w 340Pellet storage capacity kg 15

Ducted NoRight smoke outlet Yes

Colour Burgundy/old back/ivoryRecomended combustible: pellet UNIEN 14785/06. Ø6mm average length 15/20 mm. Humidity <80%

technical data units f80

Gross power kW 8.0Length mm 460Depth mm 495Height mm 830Weight kg 83

Potential volume for heating m3 195ø Smoke outlet mm 80

ø Air outlet mm 80Nominal electrical power w 395Pellet storage capacity kg 15

Ducted NoRight smoke outlet Yes

Colour Burgundy/old back/ivoryRecomended combustible: pellet UNIEN 14785/06. Ø6mm average length 15/20 mm. Humidity <80%

technical data units f110

Gross power kW 11.2Length mm 508Depth mm 545Height mm 940Weight kg 105

Potential volume for heating m3 275ø Smoke outlet mm 80

ø Air outlet mm 80Nominal electrical power w 414Pellet storage capacity kg 18

Ducted NoRight smoke outlet Yes

Colour Burgundy/old back/ivoryRecomended combustible: pellet UNIEN 14785/06. Ø6mm average length 15/20 mm. Humidity <80%

new

Judit f65

Judit f80

Judit f110

*Data may vary depending on the used combustible and the type of insulation at the house

*Data may vary depending on the used combustible and the type of insulation at the house

*Data may vary depending on the used combustible and the type of insulation at the house

Page 67: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 67

BIO

MA

SS

BIOMASSPELLET STOVES Biomass

technical data units fl110c

Gross power kW 11,2Length mm 855Depth mm 285Height mm 1160Weight kg 112

Potential volume for heating m3 275ø Smoke outlet mm 80

ø Air outlet mmNominal electrical power w 459Pellet storage capacity kg 18

Ducted YesRight smoke outlet Yes

Colour Indian BrownRecomended combustible: pellet UNIEN 14785/06. Ø6mm average length 15/20 mm. Humidity <80%

*Data may vary depending on the used combustible and the type of insulation at the house

*Data may vary depending on the used combustible and the type of insulation at the house

technical data units Bea hidro f140

Gross power kW 14,3Length mm 508Depth mm 545Height mm 1040Weight kg 130

Potential volume for heating m3 370ø Smoke outlet mm 80

ø Air outlet mmNominal tension V/Hz 230/50

Nominal electrical power w 442Pellet storage capacity kg 22

Ducted (2 engines) NoRight smoke outlet Yes

Colour Indian BrownRecomended combustible: pellet UNIEN 14785/06. Ø6mm average length 15/20 mm. Humidity <80%

*Data may vary depending on the used combustible and the type of insulation at the house

Ducted air: characteristics and models

hydro: models and characteristics

technical data units f125c

Gross power kW 12,5Length mm 508Depth mm 545Height mm 1040Weight kg 124

Potential volume for heating m3 310ø Smoke outlet mm 80

ø Air outlet mmNominal electrical power w 558Pellet storage capacity kg 23

Ducted (2 engines) YesRight smoke outlet Yes

Colour Indian Brown Recomended combustible: pellet UNIEN 14785/06. Ø6mm average length 15/20 mm. Humidity <80%

new

carmen f125c

Jessica fl110c

Bea hidro f140

Page 68: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

6868

ADVANTAGES TERMICOL PELLET STOVES

silentReduced noise thanks to the screw motor moun-ted suspended; this ways it does not transmit noisy vibrations to the rest of the structure.

easy-cleaning in full autonomyEither for the fi rst start or for the routine maintenance, the stove does not require mandatory intervention of a technician. Even the extraordinary cleaning can be carried out directly by the user, by simply unscrewing three screws we can access the body of the machine and carry out the maintenance.

rational designWe design our stoves in order to ease any ins-tallation and maintenance operations. Rational housing of all the internal components, techni-cal solutions which facilitate access and inter-ventions to all parts of the stove, intuitive and effective electronics; this is the Termicol philo-sophy at the realization of our machines.

Page 69: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 69www.termicol.es | 69

carmen: the ducted air stove with 4 enginesDistribute the hot air up to 20 meters? Drastically reduce the noise? With CArmen and its 4 engines this is possi-ble. More boost to ducted air without loosing temperatu-re but, above all, engines that can work at lower speeds with a drastic noise reduction.

exchangers in stain-less steel (aisi 304)Termicol hydro stoves are manufactured with an inno-vative design at its heater and is endowed with stain-less steel heat exchanger. This material has a high re-sistance over time and avoids any problem related to the formation of rust

Multifunction digital displayThe electronic technology of which our stoves are equipped allows to program its functioning easily.

three possibilitesfor outlet and chimny pipeIn models JUDIT, CARMEN and BEA it is possible to let out the smokes both from the rear and sideways. At the model JESSICA it is possible to direct the smoke outlet both the back side and the upper part.

Page 70: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

headquarters and Factory

sevilla | spainPh: +34 954 930 545Fax: +34 954 930 [email protected]

export

Ph: +34 954 930 [email protected]

70

Page 71: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our

www.termicol.es | 71www.termicol.es | 71

Page 72: INDEX []€¦ · manufacturing and marketing solar thermal panels and systems, and from 2014, we will also be offering solar photovoltaic, air heat pumps and biomass systems. Our