Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska 10NCEE INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM B. F. Soysal 1 and Y. Arıcı 2 ABSTRACT The common tool used in the design of gravity dams is still linear analysis. However, nonlinear tools have to be utilized for the evaluation of the seismic safety of older dams designed for lower seismic risk especially in the developed world. In contrast to the experience in linear analyses of the dam monoliths, the non-linear behavior and performance limits of these systems are not well known. This study is focused on investigation of the behavior of a gravity dam monolith using incremental dynamic analysis with the purpose of determining the development of damage on the monolith and the corresponding cracking patterns. The constitutive model for the material was calibrated first to the existing experimental results to verify the ability of the utilized cracking model to simulate the fracture in this material. Incremental dynamic analysis was then conducted using 21 different ground motions in order to assess the damage state on the dam for increasing intensity measures (IM). The relation between the development of cracking on the system and the IMs was investigated. The results show that in lieu of spectral acceleration, velocity based IM are more effective in determining the damage process on the monolith. A simple equation for the prediction of the damage development on the monolith was proposed based on the velocity characteristics of the ground motions chosen. 1 Research Assistant, Dept. of Civil Engineering, Middle East Technical University, Ankara, Turkey 06800 2 Associate Professor, Dept. of Civil Engineering, Middle East Technical University, Ankara, Turkey 06800 Soysal BF, Arıcı Y. Incremental dynamic analysis of a gravity dam. Proceedings of the 10 th National Conference in Earthquake Engineering, Earthquake Engineering Research Institute, Anchorage, AK, 2014. DOI: 10.4231/D39Z90C6T

Upload: others

Post on 16-Oct-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

Tenth U.S. National Conference on Earthquake EngineeringFrontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska 10NCEE

INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

B. F. Soysal1 and Y. Arıcı2

ABSTRACT The common tool used in the design of gravity dams is still linear analysis. However, nonlinear tools have to be utilized for the evaluation of the seismic safety of older dams designed for lower seismic risk especially in the developed world. In contrast to the experience in linear analyses of the dam monoliths, the non-linear behavior and performance limits of these systems are not well known. This study is focused on investigation of the behavior of a gravity dam monolith using incremental dynamic analysis with the purpose of determining the development of damage on the monolith and the corresponding cracking patterns. The constitutive model for the material was calibrated first to the existing experimental results to verify the ability of the utilized cracking model to simulate the fracture in this material. Incremental dynamic analysis was then conducted using 21 different ground motions in order to assess the damage state on the dam for increasing intensity measures (IM). The relation between the development of cracking on the system and the IMs was investigated. The results show that in lieu of spectral acceleration, velocity based IM are more effective in determining the damage process on the monolith. A simple equation for the prediction of the damage development on the monolith was proposed based on the velocity characteristics of the ground motions chosen.

1Research Assistant, Dept. of Civil Engineering, Middle East Technical University, Ankara, Turkey 06800 2Associate Professor, Dept. of Civil Engineering, Middle East Technical University, Ankara, Turkey 06800 Soysal BF, Arıcı Y. Incremental dynamic analysis of a gravity dam. Proceedings of the 10th National Conference in Earthquake Engineering, Earthquake Engineering Research Institute, Anchorage, AK, 2014.

DOI: 10.4231/D39Z90C6T

Page 2: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

Tenth U.S. National Conference on Earthquake EngineeringFrontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska 10NCEE

Incremental Dynamic Analysis of a Gravity Dam

B. F. Soysal1 and Y. Arıcı2

ABSTRACT The common tool used in the design of gravity dams is still linear analysis. However, nonlinear

tools have to be utilized for the evaluation of the seismic safety of older dams designed for lower seismic risk especially in the developed world. In contrast to the experience in linear analyses of the dam monoliths, the non-linear behavior and performance limits of these systems are not well known. This study is focused on investigation of the behavior of a gravity dam monolith using incremental dynamic analysis with the purpose of determining the development of damage on the monolith and the corresponding cracking patterns. The constitutive model for the material was calibrated first to the existing experimental results to verify the ability of the utilized cracking model to simulate the fracture in this material. Incremental dynamic analysis was then conducted using 21 different ground motions in order to assess the damage state on the dam for increasing intensity measures (IM). The relation between the development of cracking on the system and the IMs was investigated. The results show that in lieu of spectral acceleration, velocity based IM are more effective in determining the damage process on the monolith. A simple equation for the prediction of the damage development on the monolith was proposed based on the velocity characteristics of the ground motions chosen.

Introduction A vast number of dams are constructed in Turkey as in other developing countries in order to address the growing energy needs. In contrast to the design of many other systems integrating performance based analyses in the design procedures; the lack of experience in nonlinear analyses of dams mostly leads to a design process comprised of linear elastic analyses. Such a conservative approach is inadequate for the evaluation of thousands of dams in the developed world as it cannot account for the damage development process or yield damage indicators, i.e. relating seismic demand parameters to expected performance levels. The purpose of this study is twofolds 1) to quantify the damage process for a gravity dam using incremental dynamic analysis and explore the damage patterns and 2) to investigate the relationship between the intensity measures and the damage patterns & cumulative damage state. In order to achieve these goals, the constitutive model used for the modeling was first validated by verifying a scaled shake table test [1] simulating the fracture and propagation of cracks in this material. Then, an IDA was performed at 9 levels for 21 different ground motions. The obtained damage patterns were recorded and quantified in terms of cumulative crack length. Finally, the 1Research Assistant, Dept. of Civil Engineering, Middle East Technical University, Ankara, Turkey 06800 2Associate Professor, Dept. of Civil Engineering, Middle East Technical University, Ankara, Turkey 06800 Soysal BF, Arıcı Y. Incremental dynamic analysis of a gravity dam. Proceedings of the 10th National Conference in Earthquake Engineering, Earthquake Engineering Research Institute, Anchorage, AK, 2014.

Page 3: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

relation between the damage on the system and the seismic intensity measures was investigated in order to determine the critical properties of a ground motion determining the propagation of damage in such systems.

Analytical Simulation of Shake Table Testing on a Scaled Gravity Dam Shake Table Test and Specimen The experimental results of [1] was reproduced in this study using a finite element model in DIANA [2] in order to validate the modeling assumptions for the analytical simulation of the behavior of dam monoliths. In the shake table test [1], a plain concrete gravity dam having a height of 3.4 m was built with a 2700kg mass placed at the crest in order to reduce the natural frequency of the system (Figure 1a). Two notches having a thickness of 10 mm and a length of 250 mm were made in order to specify the crack location. The monolith was put through 3 levels of pulse excitation (Figure 1b) by scaling the first peak acceleration of the pulse to 0.87, 0.94 and 0.98g’s. The second of the consecutive tests led to a partial crack propagation on a horizontal plane on the specimen while the third test led to a complete crack between the notches at the upstream and downstream sides of the specimen. As the first pulse did not lead to cracking on the specimen, the second and the third levels of testing were named as the first and second cracking test, respectively

(a) (b)

Figure 1. (a) Dam model [1] (b) Input acceleration [1]

Analysis Results and Validation Cracking of concrete can be modeled using a discrete cracking approach or through smearing in the finite element model. In the discrete cracking model, the crack is defined as a geometrical discontinuity, while in the smeared cracking model; the cracked concrete maintains its continuum [3]. The analyses are performed using the smeared cracking model in this study. In this model, it is assumed that uncracked concrete behaves isotropically; after the occurrence of cracking, the material obeys the orthotropic law and the Poissons’ effect. A reduction factor for the tensile strength and shear retention in the crack are taken into account [3]. In order to model the tensile behavior of concrete, tension softening functions are generally used. An exponential form for the softening curve was used in this study. The mesh dependence is addressed using the fracture energy concept (Gf) and integrating an equivalent size

Page 4: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

of the finite element (h) into the constitutive model (Figure 2a). The specimen was modeled in a plane stress setting using 8 node quadrilateral elements with a discretization of approximately 10 cm (Figure 2b). Stiffness proportional damping was used in the study. In accordance with [1], the damping ratio was assumed as 1% and 10% in the first mode of the structure, respectively, for the first and second cracking tests.

σ

ε

ft

Gf/h

εmax

(a) Constitutive Model (b) Validation Model

Figure 2. Concrete Constitutive model and DIANA FE Model

In order to consider the effect of the flexibility provided by the shake table, 7 individual springs were modeled at the base of the DIANA model, similar to the analytical model used in [1]. The stiffness values of the springs were set to 230 kN/mm so as to obtain the first natural frequency of the test setup correctly. The foundation stiffness selected as such was higher than the selection by [1]. The natural frequencies henceforth obtained are compared to the empirical results and analytical model (M2) from [1] in Table 1. DIANA model is more successful in leading to a close estimation of the first five modes compared to the model in [1]. Both models had difficulty in reproducing the vertical vibration mode of the system (mode 2).

Table 1. First five natural frequencies (Hz)

Laboratory Test [1] Model M2 [1] DIANA Model f1 16.4 16.4 16.33 f2 30.0 - - f3 60.0 57.5 63.23 f4 105.0 72.0 103.14 f5 150.0 145.3 146.93

The modulus of elasticity and the compressive strength values for the concrete dam were taken from [1] as 14.8 MPa and 14.8 GPa, respectively. Tensile strength was assumed as 3.25 MPa and amplified by 1.5 in order to consider the strength increase due to dynamic loading. In accordance with [1], and a partial crack in the downstream notch was obtained for the first cracking test with FPA= 0.94g. A complete crack joining the upstream and downstream notches were obtained for the second cracking test with FPA= 0.98g. The cracking schemes for both tests are compared with the experimental results of [1] in Figure 3.

Page 5: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

(a) (b)

Figure 3. Cracking schemes (a) Experimental results of [1] (b) First and second cracking test

results

Incremental Dynamic Analysis of a Gravity Dam In this section, the development of damage on an 80 m high dam monolith will be studied by performing an incremental dynamic analysis. After a brief explanation of the modeling process for the monolith below, the incremental dynamic analysis procedure is defined along with the selected ground motions. The analysis results are then presented. Gravity Dam Model The dam investigated in this chapter is chosen as a typical 80 m high gravity dam monolith with a 6m crest length. The vertical face of the monolith is vertical while the downstream side has a slope of 1H/0.8V (Figure 4). The foundation is modeled with a finite dimension, massless mesh, according to the simplified approach introduced in [4]. The reservoir elevation is assumed as 78 m. Hydrodynamic forces are accounted for using Westergaard’s added mass approach (Eq.1) neglecting the compressibility of the reservoir [5]. p = ρ üg (1)

In this equation, p is the hydrodynamic pressure at elevation z, where z is measured from the bottom of the dam, ρ is the water density, üg is the ground acceleration and H is the reservoir elevation.

Page 6: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

Figure 4. Concrete gravity dam model

Total strain rotating crack model was utilized in the analyses with the initial Young’s Modulus, Poisson’s ratio, density and the tensile strength assumed as 12.0 GPa, 0.2, 2400 kg/m3 and 1.8 MPa, respectively. The exponential functional form of the tension softening was used in the analyses with a fracture energy of 225 N/m. It was assumed that failure will occur due to tensile overstressing [6]; therefore, the crushing failure was ignored and the compressive behavior was assumed elastic. For the foundation, a medium quality rock foundation was assumed; Young’s Modulus was taken as 10.8 GPa and the Poisson’s Ratio as 0.3. The effective damping ratio (Eq. 2) has been calculated in accordance with [4] as given below, taking into consideration the individual contributions of the dam, foundation and reservoir.

(2)

In the above equation, is the effective damping ratio, is the damping value that is suggested to be assumed as 5% for OBE level ground motions. and are the added damping ratios due to hydrodynamic effects and dam-foundation interaction, respectively. Rr is the ratio of the first natural period of the structure with full reservoir & flexible foundation case to the empty reservoir & flexible foundation case. Similarly, Rf is the ratio of the first natural period of the structure with flexible foundation & empty reservoir case to the rigid foundation & empty reservoir case. The damping ratio for the first mode was calculated as 10% from the above equations. Mass and stiffness proportional Rayleigh damping which produces 10% effective damping ratio in the first mode of the structure is used. A constant time increment of 0.005 was used in the transient analyses. The convergence norm for both the residual displacement and force criteria was selected as 0.001. Incremental Dynamic Analysis In incremental dynamic analysis (IDA), the structure is subjected to a set of ground motions which are scaled to different levels of intensity so that a relationship between the ground motion

Page 7: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

intensity measures (IM) and the response parameters are obtained. The natural (unscaled) ground motions are scaled with a positive scaling factor that increases incrementally [7]. The intensity measure (IM) is a positive scalar that depends on the intensity of a ground motion and increases incrementally with the scaling factor. The peak ground acceleration (PGA), peak ground velocity (PGV) and the 5% damped spectral acceleration at the structure’s fist-mode period (Sa(T1,5%)) are commonly used IM values for the design or evaluation of buildings [7]. The quantification of the response parameter (or the demand measure) can be subjective based on the user’s goals (design or evaluation) and constraints (capability of the analyses tools and time constraints). A range of response parameters such as the maximum crest displacement, base shear, etc… have been commonly used as response parameters. A damage measure (DM) is sought as a response parameter in this study, which is a positive observable scalar that can be obtained from the output of the non-linear dynamic analyses.

Table 2. Selected ground motions for IDA

No. Earthquake Name Component Moment Magnitude

PGA (g)

USGS Soil Type

1 Imperial Valley, 1979 315 degree 6.5 0.204 B 2 San Fernando, 1971 90 degree 6.6 0.110 B 3 San Fernando, 1971 270 degree 6.6 0.136 B 4 Landers, 1992 0 degree 7.3 0.171 B 5 Loma Prieta, 1989 0 degree 6.9 0.512 B 6 Loma Prieta, 1989 67 degree 6.9 0.357 B 7 Loma Prieta, 1989 270 degree 6.9 0.244 B 8 Morgan Hill, 1984 90 degree 6.2 0.292 B 9 Northridge, 1994 360 degree 6.7 0.514 B 10 Düzce, 1061 Lamont E 7.1 0.134 B 11 Manjil, Abbar – ABBAR Longitudinal 7.37 0.5146 B 12 Tabas Transverse 7.35 0.8518 A 13 Loma Prieta, Gilroy 337 degree 6.9 0.325 B 14 Northridge, Burbank – Hw Rd. 330 degree 6.7 0.163 B 15 Northridge, 24088 Pacoima 360 degree 6.7 0.433 B 16 Spitak 0 degree 6.8 0.199 B 17 Cape Mendocino 1992 0 degree 7.1 1.497 A 18 Chi-Chi, Taiwan, 1999 E 7.6 0.133 A 19 Kocaeli – Gebze, 1999 0 degree 7.4 0.244 A 20 Kocaeli – İzmit, 1999 90 degree 7.4 0.22 A 21 Palm Springs, 1986 270 degree 6.0 0.612 A

Selection of Ground Motions In order to perform IDA, a set of 21 ground motions are selected (Table 2) so that the effect of different characteristics of the ground motions can be investigated along with the effect of different scaled levels. The motions are chosen from the Pacific Earthquake Engineering

Page 8: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

Research (PEER) strong motion database from the ground motions recorded on rock or stiff soil (type A or B of USGS). Near fault motions (with epicentral distances of 2 to 39 km) from earthquakes in a magnitude range of 6 to 7.6 was used in accordance with [8]. The IDA was performed by scaling the selected ground motions such that the spectral acceleration at the dam’s first natural period is scaled from 0.4 to 0.8g with 0.05g increments (Figure 5). These target levels led to the use of scale factors ranging from 0.22 to 6.68.

Figure 5. Scaled acceleration response spectra of selected ground motions The Results of the Incremental Dynamic Analysis A total number of 189 analyses were conducted and the schemes of cracking were recorded for each analysis at the end of the motion. Two extreme cases of mildly-damaged and severely-damaged cracking schemes are presented in Figure 6. The selection of a damage measure for a gravity dam monolith, similar to the use of a parameter like story drift ratio in buildings, is a significant challenge. First of all, field or experimental data on dams that has undergone significant damage is extremely scarce. Secondly, a numerical index should to be tied to some qualitative performance level which is still subjective. Performance levels are still widely debated within the dam engineering community. Therefore, a relatively simpler choice is made in this study and the total crack length within the dam body was chosen as the damage measure. Cracks may start at various heights on the dam body, and occur perpendicular to the upstream (horizontal cracks) and the downstream (inclined cracks) face. Accordingly, the dam body is divided into 17 crack initiation zones with 5m increments, the first one corresponding to the cracking that would occur at the base, and the sequential ones corresponding to cracks that will form in these zones within the height of the increment (Figure 6). In accordance with [9], if more than one crack occurred in one of the crack zones, the longest crack was taken into account and the other cracks were neglected due to the well-known smearing of damage to the nearby elements along the main crack in the constitutive model. Some minor cracks in the upstream direction (that did not propagate towards the downstream cracks) were also neglected. As a demonstration of the process, the individual cracks taken into account for motion 18, scaled to 0.80g is presented in Figure 6c with red lines. The total crack length is calculated as 174 m for this example; 117 m in the upstream direction and 57 m in the downstream direction.

Page 9: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

(a) (b) (c)

Figure 6. (a) A schematic drawing of the crack zones (b) Mildly-damaged cracked scheme

(motion 7, Sa scaled to 0.80g) (c) Severely-damaged cracked scheme (motion 18, Sa

scaled to 0.80g) The effect of damage on the structure in terms of extending the fundamental period was also recognized and the elongated natural period and its effect was investigated. By simulating the discontinuities in the upstream and downstream sides separately in Eigen analyses, the change in the fundamental period was compiled, for each motion, as given in Figure 7. The obtained range is an upper bound on the damaged period considering 1) not every crack is open during a cycle of motion 2) cracks open and close (upstream and downstream side alternating) during a given earthquake shaking. When the elongated period due to the upstream and downstream cracking was investigated separately, it was observed that the influence of the upstream cracking on the period elongation was very significant, unlike the downstream cracking. With the increase in the length and number of upstream cracks, the period of the dam elongates considerably, by as much as 3 times of the initial period (motion 18, scaled to 0.80g). The effect of downstream cracking was significantly less; the elongation was limited to 20%. At average, period increases by 45% due to the damage occurring on the system. Even if the very damaging effect of motion 18 is disregarded, the period increase is 42%. A second degree polynomial can be fitted to the mean of the estimates for each design level with a correlation coefficient of 0.68 (shown in magenta in Figure 7); however, the correlation coefficient is increased to 0.81 when motion 18 is disregarded.

Figure 7. First cracked period of the dam

Page 10: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

For design of such dams or large infrastructure projects, seismic hazard analyses are commonly conducted with the purpose of obtaining a target design spectrum that is utilized for generation of ground motions. Hence, spectral acceleration is most of the time the sole IM used in the design of such structures. In this study, apart from the spectral values Sa, the peak ground velocity (PGV) and spectral velocity Sv(T1,5%) are also among the considered intensity measures [10]. For different spectral acceleration levels (i.e. different targets) the variation of the damage on this typical monolith is presented in Figure 8a. Spectral acceleration does not appear to be an effective predictor of the performance of the system. Accordingly, the effect of different IM values on the damage on the system was investigated. A preliminary relationship between the total crack length and the considered intensity measures, PGV and Sv(T1,5%) is proposed in (Eq. 3). The predictions on the crack length obtained using the proposed formulation is compared to the analyses results in Figure 8b. IM= (3)

(a) (b)

Figure 8. Total crack length of the dam (a) with spectral acceleration at first natural period (b)

with the proposed intensity measure In this equation, PGV is the peak ground velocity of the motion and Sv(T1,5%) is the spectral velocity at structure’s first natural period. From Figure 8b, it can be observed that the chosen measure successfully correlates with the behavior of the dam, with a correlation coefficient of 0.90. The velocity characteristics of the ground motion and the spectral velocity appear to be significantly affecting the damage occurring on the system. Hence, with the consideration of the velocity characteristics of the ground motion, it is possible to estimate a bound on the damage level on the monolith for the chosen target level.

Conclusions In this study, incremental dynamic analysis of an 80 m high concrete gravity dam monolith is performed in order to determine the development of damage on the monolith and the corresponding cracking patterns. The following conclusions are drawn based on the results of the study.

Page 11: INCREMENTAL DYNAMIC ANALYSIS OF A GRAVITY DAM

• The damage development on the monolith is significantly affected by the velocity characteristics of the ground motion and the spectral velocity, in lieu of the spectral acceleration values commonly used in the design of these structures.

• The spectral quantities such as PGV and Sv(T1,5%) affect the cracking behavior of dam significantly.

• Upstream cracks change the behavior of the monolith much more comprehensively compared to the inclined downstream cracks. The natural period increased to as high as 3 times the initial period with upstream cracking compared to a maximum increase of 1.2 times for the downstream cracking. A damage measure based on PGV and Sv(T1,5%) is proposed for the estimation of the damage level of the monolith. This measure can later be generalized by taking the dimensions of the dam (upstream, downstream slopes and the height) into account.

References 1. Tinawi R, Leger P, Leclerc M, Cipolla G. Seismic safety of gravity dams: from shake table experiments to

numerical analysis. Journal of Structural Engineering 2000; 126 (4): 518-529.

2. TNO DIANA. User’s Manual R. 9.4.3, 2010.

3. Rots JG. Computational Modeling of Concrete Fracture. Delft University of Technology: Delft, 1988.

4. US Army Corps of Engineers. Seismic Design Provisions for Roller Compacted Concrete Dams. Engineering and Design, EP 110-2-12: Washington, DC, 1995.

5. Westergaard HM. Water pressures on dams during earthquakes. Transactions of the American Society of Civil Engineers 1933; 98 (2): 418-433.

6. Alembagheri M, Ghaemian M. Seismic assessment of concrete gravity dams using capacity estimation and damage indexes. Earthquake Engineering and Structural Dynamics 2012; 42 (1): 123-144.

7. Vamvatsikos D, Cornell CA. Incremental dynamic analysis. Earthquake Engineering and Structural Dynamics 2002; 31 (3): 491-514.

8. FEMA. Improvement of Nonlinear Static Seismic Analysis Procedures. FEMA 440: Washington, DC, 2005.

9. El-Aidi B, Hall JF. Non-linear earthquake response of concrete gravity dams part 2: behavior. Earthquake Engineering and Structural Dynamics 1989; 18: 583-865

10. Soysal BF. Performance of Concrete Gravity Dams under Earthquake Effects. Middle East Technical University: Ankara, 2014.