increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – that...

21
PDA Europe 2012 Annual Conference –Istanbul, 12-14 November Increase the intrinsic flame retardant performance of a spray applied polyurea coating ir. Anil C. Laurent Istanbul, PDA conference 13-14 November Polyurea application driven development Challenges ahead, prepare for the future

Upload: others

Post on 25-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Increase the intrinsic flame

retardant performance of a spray

applied polyurea coating

ir. Anil C. Laurent

Istanbul, PDA conference 13-14 November

Polyurea application driven development

Challenges ahead, prepare for the future

Page 2: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

1. Market i. Trends

ii. Regulation and normalization

2. Product development i. Suprasec 2154

ii. Product details

3. Summary

4. Question and answers

Agenda Details

Page 3: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Market

What are our challenges ?

Page 4: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Page 5: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

• Buildings will change dramatically

• Are we really ready for (climate) change?

Success and reward do not come automatically

How to become well adapted to the future changes?

“Fear for Future of Native ladybird” Oxford Mail 8 Feb 2012

Challenges ahead The future will be different

Page 6: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Huntsman has created many of these MDI segments

Core Science specialists working on R&D programs

Lateral thinking to create differentiated technologies

Strong pipeline of new product innovation

1958 1990 2000 2010

PIR Insulation Sheathing

SRIM + LDSRIM Structural PU

Composite Panels

Polyurea Coating

Hydroponics

Viscoelastic Flex Foam

Noise Vibration Damping

1963

1964 1962

1978

1979 1987

2004

2008

Nike Shox

OSB

1999 1992

MDI Slabstock flexible foam

1996

Structural wood Adhesives

Cast Elastomers

MDI Molded Flex-foam

Rigid Appliance Insulation

Footwear Soling

Boardstock insulation

Challenges ahead Growth in different regions

Page 7: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

• Construction Products Regulation (the CPR) is to

ensure reliable information on construction products

in relation to their performances. This is achieved by

providing a “common technical language", offering

uniform assessment methods of the performance of

construction products.

• The Construction Products Regulation

– 305/2011/EU - CPR

• The Construction Products Directive

– 89/106/EEC – CPD

Regulations Construction products directive and regulation

Page 8: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

• EN 13501

• As raw material provider we must be

aware of these regulations.

Regulations Fire test norm

Page 9: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

New product development

Introducing Suprasec 2154

Page 10: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

1. Increase the flame retardant performance

2. Minimal diff. in properties

3. Application requires a 1:1 volume ratio

4. Offer a toolbox for formulators

5. Use non-halogenated FR additives

6. 15% NCO prepolymer as Suprasec 2054

7. Fire testing with 2 resins for cross ref.

New product development Objectives

Page 11: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

New product development Development program

Products

Selection In lab trials Spray trial Production

Initial Screening Scale up Full product

release

Objective

• Screen and selecting the FR market

• Review of the test and norms

• Screening of selected FR in prepolymer trial

• Fire testing

• Mechanical and analytical testing to ensure product stability

Results

• Small selection of FR allows prepolymer faze

• Mechanical properties ok

• Stability ok

• Combination of different FR possible provides the best fire resistance

• Retain different FR and start scale up process for spray trials

Page 12: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

New product development Development program

Products

Selection In lab trials Spray trial Production

Initial Screening Scale up Full product

release

Objective

• Review FR behavior in scale up

• Evaluate the spray ability

• Fire testing

Results

• Hot spray trial are successful

• Reactivity has not changed significantly

• Fire testing ok

Page 13: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Test Norm Slabs Spray

Gel time n/a X X

Tack Free time n/a X X

Hardness Shore A EN DIN 53505 X X

Hardness Shore D EN DIN 53505 X X

Tensile @ Break EN DIN 53504 X X

Elongation EN DIN 53504 X X

Angle Tear EN DIN 53515 X X

Taber Abrasion H 18 EN DIN 53754 X X

Fire testing (small flame) EN DIN 11925-2 X X

Fire testing (SBI) EN DIN 13823 X X

Fire testing (Cone callorimeter) EN DIN 5660 X X

New product development Development program

Page 14: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

New product development Suprasec 2154 – reactivity

Test

Slabs

2054

Slabs

2154

Spray

2054

Spray

2154

Gel time 3’ 4’ 6’’ 6’’

Tack Free time 4’ 4’ 8’’ 9’’

Page 15: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Test

Slabs

2054

Slab

2154

Spray

2054

Spray

2154

Hardness

Shore A 95 85 95 95

Hardness

Shore D 45 35 45 40

Tensile @ Break 20 10 30 10

Elongation 400 300 400 200

Angle Tear 80 40 70 40

Taber Abrasion

H 18 400 200 300 500

New product development Suprasec 2154 – Mechanical

Page 16: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Fire testing

Slabs

2054

Slab

2154

Spray

2054

Spray

2154

Small flame fail pass fail pass

Cone calorimeter n/a n/a n/a n/a

SBI n/a n/a n/a n/a

New product development Suprasec 2154 – Fire

Page 17: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

New product development Picture on 2154 flame test

Page 18: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Summary

Conclusions

Page 19: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Suprasec 2154 is a new 15% NCO

prepolymer for polyurea.

– That provides an original FR capacity

– Uses non-halogenated flame retardant

– Ensures the 1:1 ratio for hot spray application

– Is the first new prepolymer, offering a toolbox

for formulators and applicators.

New product development Conclusion

Page 20: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Questions

and answers !

Page 21: Increase the intrinsic flame retardant performance of a ... · prepolymer for polyurea. – That provides an original FR capacity – Uses non-halogenated flame retardant – Ensures

PDA Europe 2012 Annual Conference –Istanbul, 12-14 November

Thank you