ims m1000 - modular intelligent synchronization · 2017-11-09 · all ims modules will report their...
TRANSCRIPT
Meinberg Radio Clocks GmbH & Co. KG
Lange Wand 931812 Bad Pyrmont, Germany
Phone: +49 (0) 52 81 / 93 09 - 0Fax: +49 (0) 52 81 / 93 09 - 30Email: [email protected]: www.meinberg.de www.meinbergglobal.com
LANTIME M1000 IntelligentModularSynchronization
TheUltra-VersatilePlatformforYourTime andFrequencySynchronizationApplications
AllIMSModuleswillreporttheirstatustotheM1000CPUandareeasilyfield-replaceable.ThemanagementCPUcanautomaticallyapplytheconfigurationofareplacedcardtoanewlyinsertedreplacementmodule.NeworremovedCLKandI/Omoduleswillberecognizedautomatically.
PWR –PowerSupplyOptions
IMS-PWR AD10: 100-240VAC/DC,50WIMS-PWR DC20: 20-72VDC,50W
• PowersupplymodulesindicateoperationalstatustoCPU.• Redundantconfigurationpossible.• Allpowersuppliesareoperatinginloadsharingmode.
CLK –Clockandcentraltimingmodules
IMS-GPS: GPSC/A-codereceiver(12channels) Antenna/ConverterSystem(IF35.4MHz) Max.Cablelengths:300m(RG58),700m(RG213)
IMS-GLN: CombinedGPS/GLONASSreceiver(32channels) Antenna:GPS/GLONASSL1 Max.Cablelength:100m(H155lowloss) AccuracyofpulseoutputsforIMS-GPSandIMS-GLN: <±100nstoUTC(TCXO,OCXOLQ) <±50nstoUTC(OCXO-SQ,-MQ,-HQ,-DHQ)
IMS-PZF: DCF77CorrelationReceiver Accuracyofpulseoutputs: <±50µstoUTC
Redundantclockconfigurationpossible(requiresanadditional integratedRSCswitchunit)
SCU –SignalChangeoverUnit(internal)
IMS-RSC: Redundant Switching of Sync signals coming from the IMS-CLKmodules.Highavailabilityofbasictimingsignals usedforallI/Omodules(1-PPS,10MHz,TOD). Seamlessswitchingof2048kHzsignalsfortelecomapplications.
IMS-SPT: SignalPathThrough(passivecardusedinnon-redundantsystems forwardingallsignalsfromtheclock).
CPU – NTP and Management Module
IMS-C051F: 500MHz,1x10/100BASE-TFastEthernetPort NTPServer: 10.000NTPreq/s Protocols: SNMP,SSH,Telnet,DHCP,IPv4,IPv6, 802.1q,RADIUS,TACACS+ ManagementuserinterfaceviawebinterfaceorCLI
MRI –MultipleReferenceInput
IMS-MRI: Basicreferenceinputsignals(BNC) - 1PPS -10MHz -IRIG-AM(B,AFNOR,IEEE1344/C37.118) -IRIG-DCLS(B,AFNOR,IEEE1344/C37.118)
ESI –ExtendedSynchronizationInterface
IMS-ESI: Extendedreferenceinputsignals -1PPS,BNC -var.frequencies(1kHz-10MHz)unframed,BNC -var.frequencies(1kHz-10MHz)unframed,RJ45 -BITSE1/T1framed,RJ45
ESI
2MHz,2MBit/sReferencevariablefrequencyInput
LNE
NetworkExpansionCard
TSUPTP / SyncE /
HardwareNTPInterface
AC/DCPowerSupplies
PWR CLKClockModule
GPS,GLONASS,PZF
CPU
Management & NTP Module
MRIReferenceInput
IRIG,1PPS,10MHz
Modules
LNE –LANNetworkExpansion
IMS-LNE: AdditionalnetworkportsforNTPandmanagement LNE-GbE: 4x10/100/1000BASE-TGigabitRJ45Ports
TSU –PTP/SyncE/HardwareNTPInterface
IMS-TSU-GbE:GigabitEthernet(RJ45/SFPComboPort) 10nstimestampresolution 1-Step/2-stepclock IEEE1588v2multiprofilesupport: - Default1588v2profile - ITU-TG.8265andG.8275Telecomprofiles - IEEEC.37.238-2011PowerProfile - SMPTEST2059-2BroadcastProfile Layer2/Layer3/IPv4/IPv6 E2E/P2P SynchronousEthernetIn/Out (ITU-TG.8261,G.8262,G.8264ESMC)
CarrierGradeNTP(10nstimestampresolution)
REL – Relay
Errorrelaycontactmoduleforerrorindicationofclockfaults.
IMS-REL:3xDFKConnectors(3-pinCO/NO/NC)forerrorindication ofCLK-1,CLK-2andRSC(redundantsystem)or 1xDFKConnector(3-pinCO/NO/NC)forerrorindication ofCLK-1
SCG –StudioClockGenerator
WordClockfrequenciesforprofessionalAudioEquipment
IMS-SCG:• programmblewordclockrates:24Hz–24,576MHz• defaultrates:44,1kHz,48kHz,88,2kHz,96kHz• 4xBNC(2.5VTTLinto50Ω)
VSG – Video-Sync Generator
TheVSG180isavideosignalreferenceforstudioequipment.Theboardis synchronizedbyanexternal10MHzsignal.Itgeneratesconfigurablevideosignalsindifferentformatstosynchronizestudioequipment:
• Bi-LevelSync(blackburst)• Tri-LevelSync
LNO –LowNoiseOption
IMS-LNO: 10MHzsinewaveoutputs(lowphasenoise). IntegratedPLLandlowphasenoiseoscillator(OCXO-MQ/HQ).
LIU – Line Interface Unit
IMS-LIU: E1/T1-generatoravailablewith4or8outputs.
Clock Outputs:2.048MHz(E1-mode)or1.544MHz(T1-mode),G.703,75Ohm,unbalancedor2.048MHz(E1-mode)or1.544MHz(T1-mode),G.703,120Ohm,balanced.
BITS - framed outputs with SSM/BOC support:2.048Mbps(E1-mode)or1.544Mbps(T1-mode),75Ohm,unbalancedor2.048Mbps(E1-mode)or1.544Mbps(T1-mode),120Ohm,balanced.
BPE –BasicPortExpansion
Back-Endusesunmodifiedstandardsignalsprovidedbybackplane.
Front-End BackEnd
IMS-BPEavailablesignals:• 1PPS,10MHzsquare-wave• 2.048MHzsquare-wave• IRIGDCLS+AM(B,AFNOR,IEEE1344/C37.118)• ProgrammablePulsesprovidedbyclockmodule
CPE –ConfigurablePortExpansion
Thismoduleconsistsofahalf-sizestandardcontrollercard(Back-End)andadockableportexpandercard(Front-End),allowingalargevarietyofavailableandprogrammableoutputsignalsandphysicalconnectors,includingvariouselectricalandopticalinterfaces.
IMS-CPEavailableSignals:• 1PPS,10MHz• TimeCodes:IRIGA/B/E/G/AFNOR/IEEE1344/C37.118/NASA36/XR3
AMandDCLS• FrequencySynthesizer(sine-wave+TTL)• ProgrammablePulses:1PPS,1PPM,1PPH,Timer,SingleShot,• CyclicPulses,DCF77Mark,SyncStatus• Serial Timestrings (RS232 or RS422 / 485)
ACM –ActiveCoolingModule
The Active Cooling Module allows the operative use of the M1000 in hightemperatureenvironments.Ahot-plugreplacement,withouttheneedtopowerdownthesystem,ispossibleatanytime.
BPE
Basic PortExpansion
LIU
E1/T1Generator
08/2015 - www.meinbergglobal.com
KEYFEATURES
• IMS-IntelligentModularSynchronizationplatform
• Hotswappable,field-replaceablemodules
• Endlesscombinationsofmodules
• Optimizedspaceusage
• Redundantpowerandreferencesources
• Web based management for all modules
• Upto16additionalLANports
• Upto4PTP(IEEE1588-2008)modules
• VarioustypesofI/Omodules
INPUTSIGNALOPTIONSGNSS: GPS,GLONASSRadioSignal: DCF77-PZFcorrelationreceiverTimeCodes: IRIGAM,IRIGDCLSSerialString: RS232TOD+PPSPulses: 1PPSFrequencies: variablefrequencies(1kHz-10MHz)BITS/Clock: E1|T1(framed)/2.048|1.544MHz(unframed)Network: NTP,IEEE1588v2,SynchronousEthernet
All available input signals can be configured to be used within the Meinberg MRS (Multi-Reference Sources) concept. The inputs are inte-grated intotheMeinberg IRSA(IntelligentReferenceSelectionAlgorithm)technologywhichallowsuser-definedprioritizationofinputsandautomaticreferencefail-overcontrol.
PWRTwoPWRslotsareavailableforhighpowerrequirementsandoptionalredundantconfigurations.DifferentmodelsareavailablesupportingwiderangeACand/orvariousDCvoltagerange.
CLKReferenceclockmoduleslotwhichholdseitheraGPS,GLONASSorPZFreceiverincluding the main oscillator. The clock module provides standard backplanesignalslike1PPS,10MHzandaserialtimestring.UptotwoCLKslotscanoperateperbackplane.
Usable Modules: IMS-GPS: GPSReceiverIMS-GLN:GPS/GLONASSReceiverIMS-PZF: DCF77CorrelationReceiver
SCUSwitchModule (internal), requiredwhen using a redundant receiver solution.Automaticorremotecontrolledchangeoverofsignalsources,seamlesschange-overof2.048MHzreferencesignalsforredundanttelecomapplications.
CPUHoldsaCPUmodulewhichoperatesasthemainchassiscontrollerandprovideswebinterfaceandothermanagementservicesaswellasNTP.TheIMSplatformsupportsoneCPUslotperbackplane.
MRI Usable Modules:IMS-MRI: Standardreferenceinputsignals(1PPS,10MHz,IRIG-AM,IRIG-DCLS)IMS-ESI: Extendedreferenceinputsignals(1PPS,var.frequencies,E1/T1)IMS-TSU: IEEE1588v2Input/Output,SynchronousEthernetInput/Output, NTP(Output)
SlotMRI1:InputsignalsaredirectlyconnectedtoCLK1SlotMRI2:InputsignalsaredirectlyconnectedtoCLK2(redundant) Outputsignalsareavailablefrombothclocks(switched)
All ESI and IO modules can operate in MRI slots.
ESI (ExtendedSynchronizationInterface)Usable Modules:IMS-ESI: Extendedreferenceinputsignals(1PPS,var.frequencies,E1/T1)IMS-TSU: IEEE1588v2Input/Output,SynchronousEthernet(Outputonly), NTP(Output).
SlotESI1: InputsignalsaredirectlyconnectedtoCLK1SlotESI2: InputsignalsaredirectlyconnectedtoCLK2(redundant) Outputsignalsareavailablefrombothclocks(switched)
All IO modules can operate in ESI slots.
IOUsable Modules:IMS-TSU: PTP/SyncE/HardwareNTPInterfaceIMS-BPE: BasicPortExpansionIMS-CPE: ConfigurablePortExpansionIMS-LIU: Line Interface Unit (E1/T1 Telecom Signals)IMS-LNO: 1MHzsineLowNoiseOptionIMS-LNE: LANnetworkexpansionIMS-SCG: StudioClockGenerator(Audio)IMS-VSG: Video Sync. GeneratorIMS-REL: Relaycontactmodule(ErrorOut)IMS-FDM: Frequencydeviationmonitorforpowerlinenetworks
ACMI/OCPU
I/OCLK1
ESI-CLK1orI/OESI-,MRI-CLK1orI/O
PWR-1PWR-2
IMS-SlotTypes
ACMI/OCPU
CLK2CLK1
ESI-,MRI-CLK2orI/OESI-,MRI-CLK1orI/O
PWR-1PWR-2
Redundant Receiver-Slot Assignment with internal RSC Switch Logic
Single Receiver-Slot Assignment