impressed current cathodic protection for parking structures
TRANSCRIPT
![Page 1: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/1.jpg)
Impressed Current Cathodic Protection for Parking Structures
![Page 2: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/2.jpg)
2
CONCRETE PRESERVATION ALLIANCE
The Concrete Preservation Alliance is a growing coalition of organizations committed to advancing best practices in the field of concrete preservation and infrastructure renewal.
Working together to promote education and awareness of concrete repair industry standards, new and innovative corrosion prevention technologies and sustainable construction practices.
WeSaveStructures.info
![Page 3: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/3.jpg)
3
OUR MEMBERS
![Page 4: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/4.jpg)
4
WESAVESTRUCTURES.INFO
![Page 5: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/5.jpg)
5
Travis Marman, NACE CP2
Travis Marman, a NACE CP2, is a construction project developer with Vector Construction. Travis has over 10 years of experience with managing projects, operations, business development and estimating.
Travis received his Bachelor of Science in Concrete Industry Management from California State University-Chico.
Travis has worked extensively in areas related to cathodic protection installation, electrochemical chloride extraction, impressed current and post-tensioned structures.
![Page 6: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/6.jpg)
6
Topics
• What is Cathodic Protection
• Corrosion Basics
• Understand the differences between impressed current and galvanic cathodic protection systems
• Projects
• Slotted System • Mesh Overlay• Ebonex Anodes • Metalizing (Galvanic)
![Page 7: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/7.jpg)
7
Active Corrosion in Parking Structures
• Cast in Chlorides
• Marine Environments
• Deicing Salts
• Entrances / Exits • Drive Lanes
• Low Cover over Reinforcement
• Joints
• Ponding
• Coating
Corrosion Macro-Cell
Anode
Cathode
![Page 8: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/8.jpg)
8
Corrosion Cell in Concrete
Fe Fe2+ + 2e -
Fe2+ + 2Cl- FeCl2
2Fe(OH)2 + 1/2O2 Fe2O3 + 2H2O
1/2O2 + H2O + 2e - 2OH-
FeCl2 + 2OH- Fe(OH)2 + 2Cl-
2OH-
Fe3O4
γFe2O3
Fe3O4
γFe2O3
Anode
2e -
Cathode
![Page 9: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/9.jpg)
9
Widespread Corrosion
• Widespread Corrosion
• Determined by Evaluation
• Half-Cell Potential Testing • Corrosion that is active but hasn’t
started deteriorating
• Global Solutions - Impressed Current Cathodic Protection (ICCP)
• Longer life solution
• Requires maintenance
![Page 10: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/10.jpg)
10
Solution for Repairs
![Page 11: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/11.jpg)
11
Solution for Repairs / Localized Areas
![Page 12: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/12.jpg)
12
Corrosion Protection Systems
Galvanic Corrosion Protection Uses sacrificial metal anodes to provide galvanic current to the steel Minimal maintenance (low-voltage battery)
Impressed Current Cathodic Protection
Use an external power supply and inert anodes to distribute DC current to the steel Annual maintenance / monitoring required (adjustable power)
Electrochemical Treatments Change the chemistry of the concrete around the steel to facilitate passivationLong-term low-maintenance solution Protect against recontamination
![Page 13: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/13.jpg)
13
Corrosion Basics
A – anode
C – cathode
M – metallic path
E – electrolytic path
![Page 14: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/14.jpg)
14
Corrosion Circuit
Electrolyte: concrete, or water
V = IRDriving voltage is ~constant, so
Lower resistance, R, = Higher current, I
Anode (Corroding steel)-350 to -450 mV v CSE
Cathode (Passive steel)> -200 mV v CSE
Corrosion Current
(µA)Concrete
Resistance (ohm)+
0.2 to 0.4 V-
• Anode – Location where rust is formed
• Cathode – Location with no section loss
• Metallic path – steel
• Electrolyte – concrete• Requires Moisture
![Page 15: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/15.jpg)
15
What is Cathodic Protection?
• Cathodic protection (CP) • is corrosion control through the application of direct
current onto a metal, forcing it to become a cathode
• The anode delivers current into the electrolyte (metal loss, rust occurs at the anode)
• The cathode receives current from the electrolyte (The cathode is protected from section loss)
• Two main types of CP• Galvanic• Impressed current
![Page 16: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/16.jpg)
Cathodic Protection • An anode system is
embedded or attached to the surface of the concrete.
• An external current source provides power required to overcome the oxidization (corrosion) reaction at the steel surface.
• Reference electrodes provide feedback and the ability to monitor operation.
![Page 17: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/17.jpg)
17
Cathodic Protection Circuit
![Page 18: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/18.jpg)
18
Cathodic Protection Circuit
+
- PermanentDC PowerSupply
Anode
Concrete
Reinforcing Steel
Electrical Connection to Reinforcing Steel
Anode
Cathode
RcRw
Steel
+-
![Page 19: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/19.jpg)
19
Parking Garage Downtown Minneapolis, MN
![Page 20: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/20.jpg)
20
MMO Ribbon Anode Slot System
![Page 21: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/21.jpg)
MMO Ribbon Anode Slot System
![Page 22: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/22.jpg)
22
MMO Ribbon Anode Slot System
![Page 23: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/23.jpg)
23
MMO Ribbon Anode Slot System
![Page 24: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/24.jpg)
24
McCormack Building – Boston, MA
• Constructed 1972 -1975
• 22 Floors – Office Building in Beacon Hill area of Boston
• Had existing Titanium Mesh ICCP system
• ICCP system fell into disrepair
• Evaluate, remove damaged areas, and recommission system.
![Page 25: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/25.jpg)
25
Titanium Mesh Overlay System
• Uses an expanded titanium mesh anode coated with a mixed-metal oxide (MMO)
• Current distribution provided by solid titanium ribbon that is welded to the mesh
• Pinned in place with plastic anchors
• Good option for areas that have low cover over steel reinforcement throughout the structure
![Page 26: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/26.jpg)
26
Titanium Mesh Overlay System
Cathode
Anode Ti Mesh Electrolyte
Metallic Path
![Page 27: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/27.jpg)
27
Titanium Mesh Overlay System
![Page 28: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/28.jpg)
28
Titanium Mesh Overlay System
![Page 29: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/29.jpg)
29
Brentwood Towers Parking Garage – Toronto, ON
![Page 30: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/30.jpg)
30
DAC-Anode® – Conductive Coating System• Successfully used for 30 years with 10-20
years of service life expected.
• DAC-Anode® WB o single component, electrically
conductive coating applied to the surface of the concrete
• DAC-Anode® Overcoat o Flexible acrylic, crack resistant and
weather resistant.
• Distribution wire - metallurgical clad tri-metal composite used for primary distribution of the protective current to the conductive coating
![Page 31: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/31.jpg)
31
DAC-Anode® – Conductive Coating System
![Page 32: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/32.jpg)
32
DAC-Anode® – Conductive Coating System
![Page 33: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/33.jpg)
33
DAC-Anode® – Conductive Coating System
![Page 34: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/34.jpg)
34
DAC-Anode® – Conductive Coating System
![Page 35: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/35.jpg)
35
DAC-Anode® – Conductive Coating System
![Page 36: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/36.jpg)
36
Heathrow Car Park – London UK
![Page 37: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/37.jpg)
37
Discrete Ceramic Anode System
• Drill and grout system for columns, beams and slabs.• Embedded anode distributes current evenly to all
reinforcement layers.• Titanium current distribution bars embedded in grout or
epoxy are very durable.• Elements can be coated afterward if required• Ceramic / titanium composite.• Different size anodes to accommodate different
geometries.
![Page 38: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/38.jpg)
38
Discrete Ceramic Anode System
![Page 39: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/39.jpg)
39
Discrete Ceramic Anode System
![Page 40: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/40.jpg)
40
Discrete Ceramic Anode System
![Page 41: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/41.jpg)
41
Three PNC Plaza – Pittsburgh, PA
![Page 42: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/42.jpg)
42
Arc-Sprayed Zinc (ASZ+ Metalizing)
• Process goes by many different names• Metalizing• Thermally Sprayed Coating / Zinc• Arc-Sprayed Anode
• System can either be used as galvanic protection or ICCP
• Involves installing a thin coating (12 to 18 mils) of metallic zinc to protect the reinforcement
• For ICCP, all near surface metals need to be removed• Like Dac-Anode, metalizing is installed on the soffit of
the concrete
![Page 43: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/43.jpg)
43
Arc-Sprayed Zinc (ASZ+ Metalizing)
To Rectifier
![Page 44: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/44.jpg)
44
Arc-Sprayed Zinc (ASZ+ Metalizing)
![Page 45: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/45.jpg)
45
Arc-Sprayed Zinc (ASZ+ Metalizing)
![Page 46: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/46.jpg)
46
Arc-Sprayed Zinc (ASZ+ Metalizing)
![Page 47: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/47.jpg)
47
Arc-Sprayed Zinc (ASZ+ Metalizing)
![Page 48: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/48.jpg)
48
ICCP System Wiring
![Page 49: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/49.jpg)
49
ICCP System Wiring
![Page 50: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/50.jpg)
6. Battery Back-up
5. Rectifier Cards/(7 Zones)
4. Anode Wires (Red)
2. (Green) Wiring to Reference Cells3. Modem
7. AC Power input
Rectifier Cabinet
1. User interface
8. Data Collection
8. (Black) Wiring to Reinforcing Steel
![Page 51: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/51.jpg)
51
Remote Monitoring• Wireless technology advances allow
web-based CP system health monitoring
• Cellular & Satellite communication available
• System alerts sent in text message format
• Automated data collection
• Remote depolarization/ System interrogation
![Page 52: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/52.jpg)
Remote Monitoring
11 Individually
Powered Zones
![Page 53: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/53.jpg)
53
ICCP Considerations
• Care must be used when designing and installing in locations with post tensioning
• Anchorages and couplers – galvanic protection
• Will require a long-term commitment to maintain and operated rectifier(s)
• Remote monitoring • Periodic maintenance
• Can be used in combination with galvanic systems
• Galvanic solutions for repairs / ICCP for locations with active corrosion
![Page 54: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/54.jpg)
54
System Selection and Project Development
• Non-destructive testing
• Concrete sampling and testing
• Chloride profile testing
• Corrosion potential surveys
• GPR mapping
• Corrosion rate testing
![Page 55: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/55.jpg)
55
System Selection and Project Development• Columns and Beams
• Joints
• Topside Deck
• Titanium Mesh Overlay• Titanium Ribbon• Discrete Ceramic Anode System
• Soffit
• Arc-Sprayed Zinc (Metalizing)• DAC-Anode
• Galvanic Solutions
• Traffic Coatings
![Page 56: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/56.jpg)
56
System Selection and Project Development
• Design
• Zones• Staging
• Generators, compressors, etc.• Power and Water
• Phasing
• By level, bay, etc.• Asset management - funding
• Dust and Noise
• Work Hours – Nights, Days, Weekends• Containment
• Cost
![Page 57: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/57.jpg)
57
Design
1. Size and location of ICCP zones and zone circuits,
2. Layout of anode and current distribution within each zone (overall plans, part plans, and typical sections),
3. Location, characteristics and enclosed electrical components of cabinets (power supply and main),
4. Location and characteristics of junction boxes and conduit,
5. Characteristics of wiring to be used,
6. Type and location of reference cells to be used,
![Page 58: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/58.jpg)
58
Design
7. Number, type and locations of negative connections to be used,
8. Special details around structural steel columns, shear heads, and for reinforcing steel passing through steel column flanges and webs,
9. Special details around existing concrete curbs and sidewalks,
10. Special details for handling reinforcing steel with low concrete cover,
11. Capacity and type of power supplies, and
12. Schematic diagram of ICCP system and reference cell circuits.
![Page 59: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/59.jpg)
QUESTIONS?
![Page 60: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/60.jpg)
60
Contact Travis
Travis Marman
Construction Project Developer
Vector Construction
West Fargo, ND
Office: (701) 261-5579
![Page 61: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/61.jpg)
61
WEBINAR RECORDING & FUTURE EVENTS
![Page 62: Impressed Current Cathodic Protection for Parking Structures](https://reader030.vdocuments.site/reader030/viewer/2022012105/61dc181aa7dde600c97e3be7/html5/thumbnails/62.jpg)
WESAVESTRUCTURES.INFO