The Imed Gemini PC-1 is a single-channel,linear peristaltic volumetric infusion devicewith ultrasonic air detection, which can beoperated either as a controller or as a
positive-pressure pump.
-
8/4/2019 Imed Gemini PC-1
5/17
Secondary (piggyback) medications can beautomatically infused at rates and volumesindependent of the primary infusionparameters, with automatic changeover to the
primary at the conclusion of the secondaryinfusion
-
8/4/2019 Imed Gemini PC-1
6/17
The PC-1 also has a 20-step programfeature, called the VersaTaper mode, whichallows stepped program of sequential ratesand volumes for TPN or antibiotic infusion
-
8/4/2019 Imed Gemini PC-1
7/17
The pump can be configured as a Micro pump(rates from 0.1-99.9 ml/hr.) or as a Macropump (1-999 ml/hr). An RS-232 port isincluded and allows the pump to serve either
as the control or slave unit for computermonitoring.
-
8/4/2019 Imed Gemini PC-1
8/17
Rate parameters:MICRO mode 0.1-99.9 ml/hr in 0.1 ml incrementsMACRO mode 1-999 ml/hr in 1 ml increments(recommended maximum in controller mode is 500 ml/hr)
Volume limits:MICRO mode 0.1-999.9 ml. in 0.1 ml increments
MACRO mode 1-9999 ml. in 1 ml increments Battery Life:
approx. 5 hours with one channel operating at 125 ml/hr before"Help/Battery" alarm, or 4 hours with 2 channels operating at 125 ml/hr.
KVO rate:1 ml/hour, or infusion rate if less than 1 ml/hr.
Occlusion Pressure:10 2 PSI for rates above 30 ml/hr.< 10 PSI and rate-dependent for rates under 30 ml/hr., unless 10 PSI islocked-in for all rates.
Accuracy: 5 %
-
8/4/2019 Imed Gemini PC-1
9/17
a. Correctly identify key operating functions ofthe pump
b. Turns machine on
c. Primes Gemini giving set
d. Installs Gemini giving set in the infusion pump e. Sets volume to be infused
f. Changes volume to be infused
g. Sets rate of infusion
h. Changes rate of infusion i. Pauses infusion by pressing pause/stop once
j. Stops infusion by pressing pause/stop twice
-
8/4/2019 Imed Gemini PC-1
10/17
a. Low Battery
b. Air-in-line
c. Low Flow d. Total Volume Infused
e. Occluded Patient Side
f. Close Door
g. Occluded Fluid Side
-
8/4/2019 Imed Gemini PC-1
11/17
Secure mounting of infusion pumps Check for regular maintenance record
4/5 prong IV pole used
Electrical cord/connections in excellentcondition
-
8/4/2019 Imed Gemini PC-1
12/17
Label by number, the following keypad controls
and indicators.
1. Controller Infusion Mode Indicator
2. Volume to be Infused Display 3. Computer Control/Monitor Switch
4. Pause/Stop Control
5. Rate Control
6. Hundreds Digit Data Entry Control
7. Tens Digit Data Entry Control
8. Clear/Silence Control
9. P/C Mode Control
10. Battery Operation Indicator 11. AC Power Indicator
12. Sec/Piggy back Indicator
13. Sec/Piggy back Control
14. Volume Infused and Set Up Control
15. Pump Infusion Mode Indicator
16. Rate display
17. Operator Information Display
18. Rate Titration Controls 19. Power ON Control
20. Start Control
21. Volume to be Infused Control
22. Tenths Digit Data Entry Control
-