imac fieldbus mac f eldbus€¦ · the imac lpu-2 and lpu-3 units have been specifically designed...

3
TECHNICAL DATASHEET iMAC LPU Technical Datasheet IMACB018 Version 5 19 May 2020 Page 1 of 3 ampcontrolgroup.com [email protected] +61 1300 267 373 APPROVED FOR EXTERNAL DISTRIBUTION PROPERTY OF AMPCONTROL PTY LTD NOT TO BE REPRODUCED IN PART LPU Lightning Protection Units (2-wire & 3-wire) Summary The iMAC LPU-2 and LPU-3 units have been specifically designed to protect iMAC modules from high voltage transients caused by nearby lightning strikes/surges. Damage to iMAC modules is always a possibility when the modules are installed along overland conveyors. The iMAC LPU units are compact in size allowing them to be readily installed in tight places such as iMAC Pullkeys or E/stop enclosures to protect iMAC modules mounted therein. Up to three iMAC modules can be protected by a single LPU unit. In this application the LPU units provide differential voltage protection for iMAC modules connected via the iMAC fieldbus communication line. There is no common mode protection to avoid any connection to earth. The iMAC LPU modules are designed to operate in the following two modes: Minor Lightning strike/surge - The LPU Modules divert harmful energy away from the iMAC Module. Major Lightning strike/surge - The LPU becomes sacrificial, limiting damage to the iMAC Module. Data Register(s) 0 (none) Features Protects against major and minor lightning strikes/surges Protects up to 3 iMAC modules Compact fully encapsulated design 2-wire and 3-wire iMAC fieldbus versions available Minimum System iMAC Fieldbus iMAC Fieldbus Up to 3 iMAC Modules iMAC Fieldbus Up to 3 iMAC Modules CAUTION! Must NOT be installed in a hazardous area. LPU units are NOT Intrinsically Safe.

Upload: others

Post on 30-Jan-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • TECHNICAL DATASHEET

    iMAC LPU Technical Datasheet IMACB018 Version 5 19 May 2020

    Page 1 of 3 ampcontrolgroup.com

    [email protected] +61 1300 267 373

    AP

    PR

    OV

    ED

    FO

    R E

    XT

    ER

    NA

    L D

    IST

    RIB

    UT

    ION

    – P

    RO

    PE

    RT

    Y O

    F A

    MP

    CO

    NT

    RO

    L P

    TY

    LT

    D –

    NO

    T T

    O B

    E R

    EP

    RO

    DU

    CE

    D IN

    PA

    RT

    LPU Lightning Protection Units (2-wire & 3-wire)

    Summary

    The iMAC LPU-2 and LPU-3 units have been specifically designed to protect iMAC modules from high voltage transients caused by nearby lightning strikes/surges.

    Damage to iMAC modules is always a possibility when the modules are installed along overland conveyors. The iMAC LPU units are compact in size allowing them to be readily installed in tight places such as iMAC Pullkeys or E/stop enclosures to protect iMAC modules mounted therein. Up to three iMAC modules can be protected by a single LPU unit.

    In this application the LPU units provide differential voltage protection for iMAC modules connected via the iMAC fieldbus communication line. There is no common mode protection to avoid any connection to earth.

    The iMAC LPU modules are designed to operate in the following two modes:

    Minor Lightning strike/surge - The LPU Modules divert harmful energy away from the iMAC Module.

    Major Lightning strike/surge - The LPU becomes sacrificial, limiting damage to the iMAC Module.

    Data Register(s)

    0 (none)

    Features

    Protects against major and minor lightning strikes/surges

    Protects up to 3 iMAC modules

    Compact fully encapsulated design

    2-wire and 3-wire iMAC fieldbus versions available

    Minimum System

    iMAC Fieldbus

    iMAC Fieldbus

    Up to 3 iMAC Modules

    iMAC Fieldbus

    Up to 3 iMAC Modules

    CAUTION!

    Must NOT be installed in a hazardous area.

    LPU units are NOT Intrinsically Safe.

    mailto:[email protected]

  • IMACB018 LPU TECHNICAL DATASHEET Version: 5, Date: 19 MAY 2020

    Uncontrolled Copy - Refer to Ampcontrol Website for Latest Version Page 2 of 3

    AP

    PR

    OV

    ED

    FO

    R E

    XT

    ER

    NA

    L D

    IST

    RIB

    UT

    ION

    – P

    RO

    PE

    RT

    Y O

    F A

    MP

    CO

    NT

    RO

    L P

    TY

    LT

    D –

    NO

    T T

    O B

    E R

    EP

    RO

    DU

    CE

    D IN

    PA

    RT

    Electrical Connections

    LPU - 2

    L1-

    L1+ L1+

    L1-

    iMACModule

    L1-

    L1+

    iMAC Fieldbus

    L1+

    L1-

    L1A+

    2-wire

    3-wire

    RED

    BLACK

    WHITE/RED

    WHITE/BLACK

    Note: refer to iMACB094 – iMAC Installation Requirements

    Label Wire colour Type Description

    L1+ Red L1 Comms (unprotected) iMAC Fieldbus (2 wire)

    L1- Black

    L1+ White/Red L1 Comms (protected) iMAC Module (2 wire)

    L1- WhiteBlack

    LPU - 3

    L1-

    L1+

    L1A+ L1A+

    L1+

    L1-

    iMACModule

    L1-

    L1+

    L1A+WHITE

    iMAC Fieldbus

    L1+

    L1-

    L1A+

    2-wire

    3-wire

    RED

    BLACK

    WHITE/PURPLE

    WHITE/RED

    WHITE/BLACK

    Note: refer to iMACB094 – iMAC Installation Requirements

    Label Wire colour Type Description

    L1A+ White

    L1 Comms(unprotected) iMAC Fieldbus (3 wire) L1+ Red

    L1- Black

    L1A+ White/Purple

    L1 Comms (protected) iMAC Module (3 wire) L1+ White/Red

    L1- White/Black

    Specifications

    Mechanical

    Dimensions 30mm x 20mm x 15mm (See diagram below)

    Weight 60g

    IP Rating Module is fully encapsulated

    Mounting Enclosure to be mounted using double sided tape or cable ties (not supplied – e.g. 3M VHB double sided tape)

    Electrical Connections Individual 350mm flying leads (0.4mm2 PVC insulated multi-strand flexible wire with an overall outside diameter of 1.5mm)

    Environmental

    Operating Temperature -10°C to +65°C

    Protection

    DC Spark > 90VDC

    Impulse Spark < 500V spike at 100V/µs

    Impulse Discharge Current 20kA

    Find Out More

    For more information on this product, contact Ampcontrol Customer Service on +61 1300 267 373 or [email protected] or visit the Ampcontrol website: www.ampcontrolgroup.com

    mailto:[email protected]://www.ampcontrolgroup.com/

  • IMACB018 LPU TECHNICAL DATASHEET Version: 5, Date: 19 MAY 2020

    Uncontrolled Copy - Refer to Ampcontrol Website for Latest Version Page 3 of 3

    AP

    PR

    OV

    ED

    FO

    R E

    XT

    ER

    NA

    L D

    IST

    RIB

    UT

    ION

    – P

    RO

    PE

    RT

    Y O

    F A

    MP

    CO

    NT

    RO

    L P

    TY

    LT

    D –

    NO

    T T

    O B

    E R

    EP

    RO

    DU

    CE

    D IN

    PA

    RT

    Dimensions

    20

    FRONT VIEWSIDE VIEW

    3015

    Equipment List

    Part Number Description

    118911 MODULE IMAC LPU-2 WIRE

    142326 MODULE IMAC LPU-3 WIRE

    DISCLAIMER

    While every effort has been made to ensure the accuracy of this document at the date of issue, Ampcontrol assumes no liability resulting from any omissions or errors in this document, and reserves the right to revise content at any time.