iluminat solutie 1
DESCRIPTION
aTRANSCRIPT
Project 1
Partner for Contact: Order No.: Company: Customer No.:
Date: 16.01.2014Operator:
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Table of contents
Project 1Project Cover 1Table of contents 2Luminaire parts list 3PHILIPS BGP323 T35 1xECO287-2S/657 DK
Luminaire Data Sheet 4PHILIPS BGP070 GB 1xLLM3000/740
Luminaire Data Sheet 5Street 1
Planning data 6Luminaire parts list 7Photometric Results 8False Color Rendering 10Valuation Fields
Valuation Field Roadway 1Isolines (E) 11Observer
Observer 1Isolines (L) 12
Observer 2Isolines (L) 13
Valuation Field Roadway 2Isolines (E) 14Observer
Observer 3Isolines (L) 15
Observer 4Isolines (L) 16
Page 2
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Project 1 / Luminaire parts list
14 Pieces PHILIPS BGP323 T35 1xECO287-2S/657 DKArticle No.: Luminous flux (Luminaire): 23797 lmLuminous flux (Lamps): 28671 lmLuminaire Wattage: 251.5 WLuminaire classification according to CIE: 100CIE flux code: 36 77 98 100 83Fitting: 1 x ECO287-2S/657 (Correction Factor 1.000).
Page 3
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
PHILIPS BGP323 T35 1xECO287-2S/657 DK / Luminaire Data Sheet
Luminous emittance 1:
200
300
400
cd/klm 83%C0 - C180 C90 - C270
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
Luminaire classification according to CIE: 100CIE flux code: 36 77 98 100 83
SpeedStar – LEDs ensure a safe journey home Municipalities are under pressure to meet energy conservation goals by reducing their energy consumption and carbon footprint while complying with lighting norms and standards Our SpeedStar LED luminaire addresses these fundamental issues and provides a solution to reduce the impact on our environment. SpeedStar is an energy-efficient luminaire requiring minimal maintenance and incorporating the easy-to-upgrade LEDGINE, which can be connected to lighting regulation systems for further energy savings. This carbon-neutral luminaire is the ideal solution for functional road and street lighting
Due to missing symmetry properties, no UGR table can be displayed for this luminaire.
Page 4
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
PHILIPS BGP070 GB 1xLLM3000/740 / Luminaire Data Sheet
Luminous emittance 1:
200
300
400
500
cd/klm 84%C0 - C180 C90 - C270
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
Luminaire classification according to CIE: 100CIE flux code: 29 65 96 100 84
Koffer² LED – economical system When it comes to lighting residential streets, municipal authorities face a dual challenge – to ensure people’s safety while saving energy and driving down cost of ownership. This calls for functional luminaires that are energy-efficient and do not require maintenance The stylish, minimalist Koffer² LED is such a solution, its outstanding warm-white light, energy efficiency and very low maintenance meeting all the needs of today’s road users and operators. And its on-board LED module is easy to upgrade, ensuring continued savings far into the future
Due to missing symmetry properties, no UGR table can be displayed for this luminaire.
Page 5
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Planning data
Street Profile
Light loss factor: 0.67
Roadway 2 (Width: 10.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
Median 1 (Width: 1.000 m, Height: 0.000 m)
Roadway 1 (Width: 10.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
Luminaire Arrangements
25.00 m0.00
21.68 m
-0.68
Luminaire: PHILIPS BGP323 T35 1xECO287-2S/657 DKLuminous flux (Luminaire): 23797 lm Maximum luminous intensities
at 70°: 638 cd/klmat 80°: 253 cd/klmat 90°: 18 cd/klmAny direction forming the specified angle from the downward vertical, with the luminaire
installed for use.
Arrangement complies with glare index class D.6.
Luminous flux (Lamps): 28671 lmLuminaire Wattage: 251.5 WArrangement: Double row, opposingPole Distance: 25.000 mMounting Height (1): 10.000 mHeight: 9.874 mOverhang (2): -0.650 mBoom Angle (3): 15.0 °Boom Length (4): 2.000 m
Page 6
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Luminaire parts list
PHILIPS BGP323 T35 1xECO287-2S/657 DKArticle No.: Luminous flux (Luminaire): 23797 lmLuminous flux (Lamps): 28671 lmLuminaire Wattage: 251.5 WLuminaire classification according to CIE: 100CIE flux code: 36 77 98 100 83Fitting: 1 x ECO287-2S/657 (Correction Factor 1.000).
Page 7
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Photometric Results
1
2
25.00 m0.00
21.00 m
0.00
10.00
11.00
Light loss factor: 0.67 Scale 1:222
Calculation Field List
1 Valuation Field Roadway 1
Length: 25.000 m, Width: 10.000 mGrid: 10 x 6 PointsAccompanying Street Elements: Roadway 1. tarmac: R3, q0: 0.070Selected Lighting Class: ME4a (All lighting performance requirements are met.)
Lav [cd/m²] U0 Ul TI [%] SR
Calculated values: 1.96 0.77 0.70 7 0.84Required values according to class: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15 ≥ 0.50
Fulfilled/Not fulfilled:
Page 8
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Photometric Results
Calculation Field List
2 Valuation Field Roadway 2
Length: 25.000 m, Width: 10.000 mGrid: 10 x 6 PointsAccompanying Street Elements: Roadway 2. tarmac: R3, q0: 0.070Selected Lighting Class: ME4a (All lighting performance requirements are met.)
Lav [cd/m²] U0 Ul TI [%] SR
Calculated values: 1.96 0.77 0.70 7 0.84Required values according to class: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15 ≥ 0.50
Fulfilled/Not fulfilled:
Page 9
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / False Color Rendering
0 10 20 30 40 50 60 70 80 lx
Page 10
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Isolines (E)
30
30
40
40
40
50
50
25.00 m0.00
10.00 m
0.00
Values in Lux, Scale 1 : 222
Grid: 10 x 6 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
41 22 51 0.535 0.428
Page 11
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Observer 1 / Isolines (L)
1.681.68
1.68
1.681.82 1.82
1.96
1.961.96
1.96
1.96
2.10
2.10
2.10
2.10
2.10
2.10
25.00 m0.00
10.00 m
0.00
Values in Candela/m², Scale 1 : 222
Grid: 10 x 6 Points Observer Position: (-60.000 m, 2.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 1.96 0.77 0.70 6
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 12
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Observer 2 / Isolines (L)
1.80
1.80
1.95
1.95
1.95
1.95
2.10
2.10
2.10
2.10
2.10
2.10
2.10
2.25 2.25
25.00 m0.00
10.00 m
0.00
Values in Candela/m², Scale 1 : 222
Grid: 10 x 6 Points Observer Position: (-60.000 m, 7.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 2.04 0.81 0.88 7
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 13
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 2 / Isolines (E)
3030
40
4040
40
50
50
25.00 m0.00
21.00 m
11.00
Values in Lux, Scale 1 : 222
Grid: 10 x 6 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
41 22 51 0.535 0.428
Page 14
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 2 / Observer 3 / Isolines (L)
1.80
1.801.80
1.95
1.95
1.951.95
2.10
2.10
2.10
2.10
2.10
2.102.25
2.25
25.00 m0.00
21.00 m
11.00
Values in Candela/m², Scale 1 : 222
Grid: 10 x 6 Points Observer Position: (-60.000 m, 13.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 2.04 0.81 0.88 7
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 15
Project 1
16.01.2014
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 2 / Observer 4 / Isolines (L)
1.68
1.68
1.68
1.681.82
1.82
1.82
1.96
1.96
1.96
1.96
2.10
2.102.10
2.10
2.10
2.10
25.00 m0.00
21.00 m
11.00
Values in Candela/m², Scale 1 : 222
Grid: 10 x 6 Points Observer Position: (-60.000 m, 18.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 1.96 0.77 0.70 6
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 16