ifm catalogue australia 2010

237
2010 fluid sensors and diagnostic systems bus, identification and control systems position sensors and object recognition 7844 x Made in Germany 7844 x Made in Germany ifm efector – close to you!

Upload: hoekda

Post on 16-Oct-2014

260 views

Category:

Documents


22 download

TRANSCRIPT

2010

fluid sensors and diagnostic

systems

bus, identification

and control systems

position sensors

and objectrecognition

7844 xMade in Germany7844 xMade in Germany

ifm efector – close to you!

visit our website:

www.ifmefector.com.au

We

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

04/

10

Over 70 locations worldwide – at a glance at

Australia

ifm efector pty ltd.P.O. Box 4084Suite 3, 745 Springvale RoadMulgrave VIC 3170Tel. 1300 365 088Fax 1300 365 [email protected]

New Zealand

ifm efector pty ltd.Unit B, 20 Cain RoadPenrose, AucklandTel. +64 / 95 79 69 91Fax +64 / 95 79 92 [email protected]/nz

www.ifm.com

ifm efector – close to you!

ifm – the company 6 - 7

General information 8 - 9

List of articles / approvals 10 - 15

Inductive sensors 17 - 37

Capacitive sensors 39 - 47

Cylinder sensors 49 - 56

Safety technology 59 - 62

Valve sensors 65 - 67

Photoelectric sensors infrared / redlight 69 - 84

Photoelectric sensors laser 87 - 91

Photoelectric sensors fibre optics 93 - 98

Photoelectric sensors specific systems 101 - 106

Object recognition 109 - 112

Encoders 115 - 119

Evaluation systems 121 - 125

Level sensors 127 - 135

Flow sensors 137 - 150

Pressure sensors 153 - 164

Temperature sensors 167 - 180

Diagnostic systems 183 - 188

Bus system AS-interface 191 - 206

Multicode reading systems 209 - 211

RF-identification systems 213 - 216

Power supplies 219 - 222

Connection technology 225 - 234

ifm – worldwide addresses 236 - 237

The company in your vicinity.

State-of-the-art communication.

With the right address – www.ifm.com – only a mouse click separates you from theworld of automation technology. See the power of our products in interactive repre-sentations. Gain an impression with 3-dimension-al views of our units. DownloadCAD drawings for direct integration in your applications. And one more innovationon the internet: The e-shop – already available in many countries. Order online – noweven faster, more convenient and reliable.

We are there for you.

Close contact with our customers is part of our success. Therefore we have consi-stently developed our sales network right from the start. Today ifm electronic isrepresented in more than 70 countries – close to you! With application advice andservice at the heart of our operation. For the introduction of new products and tech-nologies we support you with workshops and seminars in our training centres or inyour plant.

Security by success.

Since its foundation in 1969 ifm electronic has constantly grown, now having morethan 3300 employees worldwide, and achieved a turnover of EUR 340 million in2009. This success gives you the security of having a reliable partner for the imple-mentation of your automation projects. Comprehensive service and a warranty of upto 5 years on standard units are just two examples of this reliability.

1980 1990

200

100

0

300

2000

400

1970

500

sale

s de

velo

pmen

t in

mill

ion

EU

R

Turnoverdevelopmentsince 1970.

ifm – the company

6www.ifm.com

ifm – the company

7

A sign of innovation.

Not only components.

ifm stands for a large range of different sensors and systems for automation. Ourrange of more than 8000 articles guarantees flexibility and compatibility. So there isalways a reliable solution for your automation projects – from the individual sensorwith practical accessories to the complete system.

Availability guaranteed.

Your deadlines matter to us. That is why we are constantly optimising our productionprocesses in order to be able to quickly and flexibly produce large quantities at a con-stantly high quality – and to continue to shorten delivery times. Your order is dispat-ched via our centralised logistics centre reliably and on time.

Quality as part of our philosophy.

The quality standard of our products is an integral part of our company philosophy.And we guarantee it! So we provide you, the users, with a maximum degree of secu-rity: By means of our own production technology, ifm film technology, as well as bymeans of extensive quality assurance measures such as 100 % final testing. By quali-ty we understand, for example, ecologically conscious production – Made in Germa-ny!

The developmentof innovative

products is oneof our core

competences.Under the name of

i-step we havecome up with a

new product gene-ration which

implements sophi-sticated technolo-gies in industrially

compatible andeasy to handleproducts. From

high-quality stan-dard solutions to

products speciallytailored to the

requirements ofthe individual

industries – frommobile machines

to the foodindustry.

www.ifm.com

www.ifm.comInformation around the clock andaround the globe in 22 languages on the internet.

• Information

- product innovations- company news- exhibition info- locations- jobs

• Documentation

- data sheets- operating instructions- manuals- approvals- CAD data

• Communication*

- request for documents- recall service- live advice- newsletter

• Selection

- interactive product selection aids- configuration tools- data sheet direct

• Animation

- virtual product animations- flash movies (video sequences)

• Application

- applications- product recommendations- calculation aids

• Transaction*

- e-shop processing- e-procurement catalogues- B2B services

*Some offered information is available country-specific

General information

8www.ifm.com

General information

9

Convenient order processingvia the e-shop** on the internet.

Secured authentication

Customer-related priceindication

Real time availability check

Personal product favourites

Online parcel tracking

Individual order history

Convenient quick input form

Simple order processing

Management of shippingaddresses

Confirmations by e-mail

** Already available in many countries.

www.ifm.com

List of articles / approvals

10www.ifm.com

Orderno.

Approvals Cataloguepage

AC002S CE, CUL 197

AC004S CE, CUL 197

AC005S CE, CUL 197

AC007S CE, CUL 197

AC009S CE, CRUUS 197

AC010S CE, CSA, UL 198

AC012S CE 198

AC015S CE, CRUUS 198

AC030S CE, CUL 197

AC031S CE 197

AC032S CE 197

AC1144 CE 199

AC1146 CE 193

AC1147 CE 193

AC1212 CE, CUL 194

AC1218 CE, CRUUS 194

AC1220 CE 194

AC1221 CE 194

AC1236 CE, CUL 194

AC1244 CE, CUL 194

AC1326 CE, CUL 193

AC1327 CE, CUL 193

AC1337 CE, CUL 193

AC1354 CE, CUL 193

AC1375 CE, CUL 193

AC1376 CE, CUL 193

AC2086 CE 195

AC2216 CE, CUL 194

AC2225 CE 193

AC2251 CE, CRUUS 194

AC2252 CE, CRUUS 194

AC2254 CE, CRUUS 194

AC2257 CE, CRUUS 194

AC2264 CE, CRUUS 194

AC2411 CE 195

AC2412 CE 196

AC2417 CE 195

AC2451 CE 195

AC2452 CE 196

AC2457 CE, CUL 195

AC2729 CE, CRUUS 194

AC2730 195

AC2900 CE, CUL 196

AC2904 CE, CUL 196

AC2910 CE, CUL 196

AC2916 CE, CUL 196

AC3000 200

AC4000 CE 200

AC4002 CE 200

AC4007 200

Orderno.

Approvals Cataloguepage

AC4008 200

AC5000 CUL 196

AC5003 CUL 196

AC5014 196

AC5015 196

AC5031 197, 199

AC5204 CE, CUL 195

AC5208 CE, CUL 195

AC5214 CE, CUL 195

AC5215 CE, CUL 195

AC5222 CE, CUL 195

AC5228 CE 197

AC5235 CE, CUL 195

AC5246 CE 197

DD2003 CE, CUL 123

DI0001 CE 123

DI5001 CE 123

DI5009 CE 123

DI6001 CE, CUL 123

DN1030 CE 221

DN1031 CE 221

DN2013 CE, CUL 221

DN2014 CE, CUL 221

DN2032 CE, CUL 221

DN2033 CE, CUL 221

DN2035 CE, CUL 221

DN2036 CE, CUL 221

DN3011 CE, CRUUS, CUL 221

DN3012 CE, CRUUS, CUL 221

DTA100 CE, CUL 198, 215

DTA300 CE, CUL 198, 215

DX2003 CE 123

E10017 159, 173, 29

E10191 228

E10200 228

E10734 28

E10735 28, 43

E10736 124, 28, 44

E10737 124, 28, 44

E11030 44

E11031 44

E11032 44

E11033 44

E11034 44

E11036 44

E11047 29

E11048 29

E11078 44

E11220 230

E11221 230

Orderno.

Approvals Cataloguepage

E11223 230

E11224 230

E11232 111, 228

E11248 CRUUS 228

E11249 CRUUS 228

E11495 CRUUS 230

E11496 CRUUS 230

E11498 CRUUS 230

E11499 CRUUS 230

E11504 CRUUS 228

E11505 CRUUS 228

E11508 CRUUS 227

E11509 CRUUS 227

E11521 28

E11530 29

E11531 29

E11533 29

E11534 29

E11572 185

E11664 185

E11697 228

E11796 54

E11797 54

E11798 54

E11799 54

E11801 54

E11816 53

E11817 53

E11818 53

E11819 53

E11820 53

E11821 53

E11822 53

E11823 53

E11877 53

E11914 54

E11928 54

E11929 61

E11958 54

E11959 54

E11960 54

E11961 54

E12004 54

E12153 45

E12208 67

E12209 67

E19503 29

E20004 77

E20005 77

E20600 96

List of articles / approvals

11www.ifm.com

Orderno.

Approvals Cataloguepage

E20615 95

E20639 95

E20718 29, 44

E20722 104, 90

E20738 228

E20765 96

E20767 96

E20768 96

E20773 96

E20774 96

E20860 29

E20861 29

E20870 29, 44

E20873 29, 44

E20874 29, 44

E20903 78

E20907 78

E20911 78

E20915 78

E20939 111, 112

E20941 111, 211

E20952 111

E20953 77

E20954 77

E20956 77

E20965 78

E20969 78

E20974 78, 90

E20984 78

E20993 89

E20994 89

E21015 78

E21084 79

E21087 104, 79

E21088 215, 79

E21117 79

E21120 79

E21125 78

E21126 78

E21166 111, 211

E21200 78

E21237 CE 78

E2D101 104, 90

E2D110 111, 211

E2D200 111

E2I200 211

E30006 132, 159

E30007 132, 160

E30016 174

E30017 174

Orderno.

Approvals Cataloguepage

E30018 174

E30047 174

E30052 FDA 132, 161

E30055 EHEDG 174

E30056 EHEDG 174

E30064 161

E30089 174

E30090 174

E30094 159, 175

E30098 185

E30104 132, 159

E30112 111, 186

E30115 187

E30116 160

E30122 EHEDG 132, 145

E30128 161

E30393 EHEDG 175

E30396 CE 159, 173

E30399 132, 159

E30400 132, 160

E30401 132, 160

E30402 132, 160

E30403 EHEDG 175

E33001 132, 161

E33002 161

E33201 EHEDG, FDA 132, 144

E33202 EHEDG, FDA 144, 160

E33222 EHEDG, FDA 144, 160

E33401 EHEDG 175

E33402 EHEDG 175

E33701 EHEDG, FDA 132, 144

E33702 EHEDG, FDA 144, 160

E33721 EHEDG, FDA 144, 160

E33722 EHEDG, FDA 145, 160

E34410 174

E35010 175

E37010 175

E3D103 112

E3D200 112

E40057 144

E40096 144, 175

E40099 144, 175

E40101 144, 174

E40107 175

E40114 143, 174

E40115 143

E40124 144, 174

E40128 143, 174

E40129 144

E40138 144

Orderno.

Approvals Cataloguepage

E40189 145

E40196 145

E40199 145

E43201 131

E43202 131

E43203 131

E43204 131

E43205 131

E43207 131

E43208 131

E43209 131

E43901 44

E43903 45

E43910 131

E60028 118

E60033 118

E60034 118

E60063 118

E60064 118

E7001S 199

E7005S 199

E70062 200

E70096 199

E70213 199

E70230 CRUUS 198

E70231 198

E70297 199

E70320 199

E70354 CUL 196, 199

E70413 200

E70454 CUL 196, 199

E73004 199

E75232 200

E80302 200, 215

E80317 200, 215

E80320 200, 215

E89005 CE 123

E89150 CE 124

EBC027 229

EBC031 229

EBC035 229

ENC02A 231

ENC05A 231

ENC11A 231

EVC002 CRUUS 227, 229

EVC003 CRUUS 227, 229

EVC005 CRUUS 227, 229

EVC006 CRUUS 227, 229

EVC094 CRUUS 228

EVC142 CRUUS 227

List of articles / approvals

12www.ifm.com

Orderno.

Approvals Cataloguepage

EVC143 CRUUS 227

EVC145 CRUUS 227

EVC146 CRUUS 227

EVC148 CRUUS 227

EVC149 CRUUS 227

EVC151 CRUUS 227

EVC152 CRUUS 227

EVC154 CRUUS 227

EVC155 CRUUS 227

EVT001 CRUUS 230

EVT002 CRUUS 230

EVT004 CRUUS 230

EVT005 CRUUS 230

EVT007 CRUUS 230

EVT008 CRUUS 230

EVT010 CRUUS 231

EVT013 CRUUS 230

EVT040 CRUUS 230

EVT041 CRUUS 230

EVT042 CRUUS 230

EVT043 CRUUS 230

EVT044 CRUUS 230

EVT058 CRUUS 231

EVT060 CRUUS 231

EVT061 CRUUS 231

EVT062 CRUUS 231

EVW002 CRUUS 229

EVW003 CRUUS 229

EVW005 CRUUS 229

EVW006 CRUUS 229

EVW008 CRUUS 229

EVW009 CRUUS 229

G1501S CE, CUL 61

G1502S CE 61

G1503S CE, CUL 61

G2001S CE 104

GF711S CE, CUL 61

GG711S CE, CUL 61

GI711S CCC, CE 61

ID0013 CCC, CE, CUL 21

ID5046 CE, CUL 22

ID5058 CE 22

ID5059 CE, CUL 25

IE5338 CE, CUL 19

IE5340 CE, CUL 19

IE5343 CE, CUL 19

IE5345 CE, CUL 19

IER200 CE, CUL 24

IF0005 CCC, CE 20

IF0007 CCC, CE 20

Orderno.

Approvals Cataloguepage

IF502A CE 28

IFC204 CE, CUL 23

IFC205 CE, CUL 23

IFC206 CE, CUL 23

IFM205 CCC, CE, CUL, E1 24

IFM206 CCC, CE, CUL, E1 24

IFR200 CE, CUL 24

IFS204 CE, CUL 21

IFS205 CE, CUL 21

IFS208 CE, CUL 21

IFS209 CE, CUL 21

IFT200 CE, CUL 25

IFT202 CE, CUL 26

IFT203 CE, CUL 25

IFT205 CE, CUL 26

IFT206 CE, CUL 26

IFT208 CE, CUL 26

IFT240 CE, CUL 25

IG0011 CCC, CE, CUL 20

IG0012 CCC, CE 20

IG509A CE 28

IGC204 CE, CUL 23

IGC205 CE, CUL 23

IGC206 CE, CUL 23

IGM204 CCC, CE, CUL, E1 24

IGM205 CCC, CE, CUL, E1 24

IGR200 CE, CUL 24

IGS204 CE, CUL 21

IGS205 CE, CUL 21

IGS208 CE, CUL 21

IGS209 CE, CUL 22

IGT200 CE, CUL 26

IGT202 CE, CUL 26

IGT203 CE, CUL 26

IGT205 CE, CUL 26

IGT206 CE, CUL 26

IGT208 CE, CUL 26

IGT247 CE, CUL 25

II0011 CE, CUL, CCC 20

II0012 CE, CUL, CCC 20

II501A CE 28

IIC200 CE, CUL 23

IIC201 CE, CUL 23

IIM208 CCC, CE, CUL, E1 24

IIM209 CCC, CE, CUL, E1 24

IIR200 CE, CUL 24

IIS204 CE, CUL 22

IIS205 CE, CUL 22

IIS206 CE, CUL 22

IIS207 CE, CUL 22

Orderno.

Approvals Cataloguepage

IIT002 CCC, CE, CUL 27

IIT200 CE, CUL 26

IIT202 CE, CUL 27

IIT204 CE, CUL 26

IIT205 CE, CUL 26

IIT207 CE, CUL 27

IIT209 CE, CUL 27

IIT228 CE, CUL 25

IL5020 CE, CUL 19

IM0010 CCC, CE, CUL 20

IM0011 CCC, CE, CUL 20

IM0049 CCC, CE 21

IM0054 CCC, CE 21

IM5020 CE, CUL 20

IM5037 CCC, CE 20

IM5038 CCC, CE 20

IM503A CE 28

IM5046 CE 20

IM504A CE 28

IM5115 CE, CUL 22

IM5116 CE, CUL 22

IM5117 CE, CUL 22

IM5123 CE, CUL 22

IM5124 CE, CUL 22, 25

IM5126 CE, CUL 22, 25

IM5127 CE 23

IM5136 CE, CUL 22

IN5121 CE 19

IN5129 CE 19

IN5409 CE 67

IS5026 CE, CUL 19

IS5070 CE 19

IT5042 CE, CUL 19

IT5043 CE, CUL 19

IV5003 CE 20

IV5004 CE 20

IV5025 CE 25

IY5051 CE 19

IZ5047 CE, CUL 19

IZ5048 CE, CUL 19

IZ5051 CE 19

JAT201 CE 23

KD0009 CCC, CE 42

KD5018 CE 41

KG0009 CCC, CE 41

KG0010 CCC, CE 41

KG5065 CE, CUL 42

KI0016 CCC, CE, CUL 41

KI0020 CCC, CE, CUL 42

KI0054 CE 43

List of articles / approvals

13www.ifm.com

Orderno.

Approvals Cataloguepage

KI5001 CE, CUL 41

KI5002 CE, CUL 41

KI5030 CCSAUS, CE, FM, IEC 43

KI5082 CE, CUL 42

KI5084 CE, CUL 41

KI5085 CE, CUL 41

KI5087 CE, CUL 41

KQ6001 CE, CUL 42

KQ6003 CE, CUL 42

KQ6005 CE, CUL 42

KX5001 CCSAUS, CE, FM 43

LI5141 CE, CUL 131

LI5142 CE, CUL 131

LI5143 CE, CUL 131

LI5144 CE, CUL 131

LK1022 CE, CUL 129

LK1023 CE, CUL 129

LK1024 CE, CUL 129

LK3122 CE, CUL 129

LK3123 CE, CUL 129

LK3124 CE, CUL 129

LK8122 CE, CUL 129

LK8123 CE, CUL 129

LK8124 CE, CUL 129

LR3000 CE, CUL 129

LR7000 CE, CUL 129

LR8000 CE, CUL 129

MK5100 CE, CUL 51

MK5101 CE, CUL 51

MK5102 CE, CUL 51

MK5103 CE, CUL 51

MK5104 CE, CUL 51

MK5106 CE, CUL 51

MK5107 CE, CUL 51

MK5108 CE, CUL 51

MK5110 CE, CUL 52

MK5111 CE, CUL 52

MK5138 CE, CUL 52

MK5139 CE, CUL 52

MK5140 CE, CUL 52

MK5157 CE, CUL 52

MK5300 CE, CUL 52

MK5301 CE, CUL 53

MK5302 CE, CUL 53

MK5306 CE, CUL 52

MK5307 CE, CUL 53

MR0100 CE 51

MR0107 CE 51

N0531A CE, CSA, FM, IEC 28, 43

N0532A CE, CSA, FM, IEC 28, 43

Orderno.

Approvals Cataloguepage

N0534A CE, CSA, FM, IEC 28, 43

NF500A CCSAUS, CE, FM, IEC 27

NF501A CCSAUS, CE, FM, IEC 27

NG500A CCSAUS, CE, FM, IEC 27

NG501A CCSAUS, CE, FM, IEC 27

NI500A CCSAUS, CE, FM, IEC 27

NI501A CCSAUS, CE, FM, IEC 27

O1D100 CE, CUL 103

O1D101 CE, CUL 89

O1D103 CE, CUL 103

O1D105 CE, CUL 103

O1D106 CE, CUL 103

O1D155 CE, CUL 103

O1D300 CE, CUL 103

O2D220 CE, CUL 111

O2I100 CE, CUL 211

O3D200 CE 111

O4E500 CE, CUL 77

O4H500 CE, CUL 77

O4P200 CE, CUL 77

O4P500 CE, CUL 77

O4S500 CE, CUL 77

O5C500 CE, CUL 103

O5E200 CE, CUL 76

O5G500 CE, CUL 103

O5H200 CE, CUL 76

O5H500 CE, CUL 76

O5P200 CE, CUL 76

O5S200 CE, CUL 76

O7E200 CE 76

O7H200 CE 76

O7H202 CE 76

O7H204 CE 76

O7P200 CE 76

O7S200 CE 75

OBF500 CE, CUL 95

OD5005 CE 103

OD5007 CE 103

OD5009 CE 104

OD5011 CE 104

OD5013 CE 104

OG0030 CCC, CE, CUL 73

OG0033 CCC, CE 73

OG0035 CCC, CE 73

OG0039 CCC, CE 73

OG5123 CE, CUL 72

OG5124 CE, CUL 72

OG5125 CE, CUL 72

OG5126 CE, CUL 72

OG5127 CE, CUL 72

Orderno.

Approvals Cataloguepage

OG5128 CE, CUL 72

OG5129 CE, CUL 72

OGE100 CE, CUL 71

OGE200 CE, CUL 71

OGE280 CE, CUL 73

OGE281 CE, CUL 73

OGE500 CE, CUL 71

OGE700 CE, CUL 89

OGH200 CE, CUL 71

OGH280 CE, CUL 73

OGH300 CE, CUL 72

OGH500 CE, CUL 72

OGH580 CE, CUL 73

OGH581 CE, CUL 73

OGH700 CE, CUL 89

OGP100 CE, CUL 71

OGP200 CE, CUL 71

OGP201 CE 71

OGP280 CE, CUL 73

OGP281 CE, CUL 73

OGP282 CE, CUL 73

OGP300 CE, CUL 72

OGP500 CE, CUL 72

OGP700 CE, CUL 89

OGS100 CE, CUL 71

OGS200 CE, CUL 71

OGS280 CE, CUL 73

OGS500 CE, CUL 71

OGS700 CE, CUL 89

OGT100 CE, CUL 71

OH5003 CE 74

OH5005 CE 74

OH5007 CE 74

OH5011 CE 74

OH5012 CE 74

OJ5023 CE, CUL 74

OJ5027 CE, CUL 74

OJ5032 CE, CUL 74

OJ5071 CE, CUL 74

OJ5122 CE, CUL 75

OJ5126 CE, CUL 75

OJ5130 CE, CUL 74

OJ5131 CE, CUL 74

OJ5148 CE, CUL 75

OJ5154 CE, CUL 89

OJ5158 CE, CUL 89

OJ5186 CE, CUL 103

OL0004 CCC, CE 75

OL0005 CCC, CE 75

OL0006 CE 75

List of articles / approvals

14www.ifm.com

Orderno.

Approvals Cataloguepage

OL0007 CCC, CE 75

OO5000 CE, CUL 95

OO5001 CE, CUL 95

OO5002 CE, CUL 95

OO5003 CE, CUL 95

OY120S CE 104

OY121S CE 104

OY122S CE 104

PA3020 CE 156

PA3021 CE 156

PA3022 CE, CUL 156

PA3023 CE, CUL 156

PA3024 CE, CUL 156

PA3026 CE, CUL 156

PA3027 CE, CUL 156

PA3028 CE, CUL 130, 156

PA3029 CE, CUL 156

PA3060 CE 156

PF2652 CE, CUL, EHEDG, FDA 158

PF2653 CE, CUL, EHEDG, FDA 158

PF2654 CE, CUL, EHEDG, FDA 158

PF2656 CE, CUL, EHEDG, FDA 158

PF2657 CE, CUL, EHEDG, FDA 158

PF2658 CE, CUL, EHEDG, FDA 158

PG2451 CE 158

PG2452 CE 158

PG2453 CE 158

PG2454 CE 158

PG2456 CE 158

PG2457 CE 158

PG2458 CE 158

PG2489 CE 158

PG2789 CE, EHEDG, FDA 130, 158

PG2793 CE, CUL, EHEDG, FDA 158

PG2794 CE, CUL, EHEDG, FDA 158

PG2795 CE, CUL, EHEDG, FDA 158

PG2796 CE, CUL, EHEDG, FDA 130, 158

PG2797 CE, CUL, EHEDG, FDA 130, 158

PG2798 CE, CUL, EHEDG, FDA 130, 158

PG2799 CE, CUL, EHEDG, FDA 130, 158

PI1093 CE, CUL, EHEDG, FDA 157

PI1094 CE, CUL, EHEDG, FDA 157

PI1095 CE, CUL, EHEDG, FDA 157

PI1096 CE, CUL, EHEDG, FDA 157

PI1097 CE, CUL, EHEDG, FDA 130, 157

PI1099 CE, CUL, EHEDG, FDA 130, 157

PI1693 CE, CUL, EHEDG, FDA 157

PI1694 CE, CUL, EHEDG, FDA 157

PI1695 CE, CUL, EHEDG, FDA 157

PI1696 CE, CUL, EHEDG, FDA 157

Orderno.

Approvals Cataloguepage

PI1697 CE, CUL, EHEDG, FDA 157

PI1698 CE, CUL, EHEDG, FDA 157

PI1699 CE, CUL, EHEDG, FDA 157

PI2093 CE, CUL, EHEDG, FDA 157

PI2094 CE, CUL, EHEDG, FDA 157

PI2095 CE, CUL, EHEDG, FDA 157

PI2096 CE, CUL, EHEDG, FDA 157

PI2097 CE, CUL, EHEDG, FDA 130, 157

PI2098 CE, CUL, EHEDG, FDA 130, 157

PI2099 CE, CUL, EHEDG, FDA 130, 157

PI2789 CE, CUL, EHEDG, FDA 130, 157

PI2793 CE, CUL, EHEDG, FDA 157

PI2794 CE, CUL, EHEDG, FDA 157

PI2795 CE, CUL, EHEDG, FDA 157

PI2796 CE, CUL, EHEDG, FDA 130, 157

PI2797 CE, CUL, EHEDG, FDA 130, 157

PI2798 CE, CUL, EHEDG, FDA 130, 157

PI2799 CE, CUL, EHEDG, FDA 130, 157

PIM693 CE, CUL, EHEDG, FDA 158

PIM694 CE, CUL, EHEDG, FDA 158

PK6520 CE, CUL 155

PK6521 CE, CUL 155

PK6522 CE, CUL 155

PK6523 CE, CUL 155

PK6524 CE, CUL 155

PM2053 CE, CUL, EHEDG, FDA 159

PM2054 CE, CUL, EHEDG, FDA 159

PM2057 CE, CUL, EHEDG, FDA 159

PM2058 CE, CUL, EHEDG, FDA 159

PMP094 CE, CUL, EHEDG, FDA 159

PMP095 CE, CUL, EHEDG, FDA 159

PMP096 CE, CUL, EHEDG, FDA 159

PMP097 CE, CUL, EHEDG, FDA 159

PN2009 CE, CUL 155

PN2020 CE, CUL 155

PN2021 CE, CUL 155

PN2022 CE, CUL 155

PN2023 CE, CUL 155

PN2024 CE, CUL 155

PN2026 CE, CUL 155

PN2027 CE, CUL 155

PN2028 CE, CUL 155

PN2069 CE, CUL 129, 155

PP2001 CE, CUL 159

PQ7809 CE 155

PQ7834 CE 155

PS3208 CE 130, 156

PS3407 CE 130, 156

PS3417 CE 130, 156

PT3550 CE, CUL 156

Orderno.

Approvals Cataloguepage

PT3551 CE, CUL 156

PT3552 CE, CUL 156

PT3553 CE, CUL 156

PT3554 CE, CUL 156

PT9550 CE, CUL 156

PT9551 CE, CUL 156

PT9552 CE, CUL 156

PT9553 CE, CUL 156

PT9554 CE, CUL 156

PY2068 CE, CUL 129, 155

RB1015 CE, CRUUS 117

RB6009 CE, CRUUS 117

RB6015 CE, CRUUS 117

RB6029 CE, CRUUS 117

RM3005 CE, CRUUS 117

RM7003 CE, CRUUS 118

RM7004 CE, CRUUS 118

RN7003 CE, CRUUS 117

RN7004 CE, CRUUS 117

RO6344 CE, CRUUS 117

RO6345 CE, CRUUS 117

RU1016 CE, CRUUS 117

RU1025 CE, CRUUS 117

SD2000 CE, CUL 142

SD5000 CE, CUL 142

SD6000 CE, CUL 142

SD6100 CE, CUL 143

SD8000 CE, CUL 142

SD9000 CE, CUL 142

SF211A TIIS 141

SF221A 141

SF320A IEC 141

SF321A IEC 141

SF5200 CUL 140

SF5350 CUL 140

SF5700 CUL 140

SF5800 CUL 140

SF6200 CUL 140

SI5000 CE, CUL 139

SI5004 CE 139

SI5006 CE, CUL 139

SI5007 CE, CUL 140

SI5010 CE, CUL 139

SI6600 CE, CUL, EHEDG, FDA 140

SI6700 CE, CUL, EHEDG, FDA 140

SI6800 CE, CUL, EHEDG, FDA 140

SL0101 CE 142

SL5101 CE 142

SM6050 CE, CUL 139

SM6100 CE, CUL 139

List of articles / approvals

15www.ifm.com

Orderno.

Approvals Cataloguepage

SM7100 CE, CUL 139

SM8100 CE, CUL 139

SN0150 CE, CUL 141

SN2301 CE, IEC 142

SN2302 CE, IEC 142

SQ0500 CE, CUL 143

SR0150 CE, CUL 141

SR2301 CE, IEC 142

SR5900 CE, CUL 141

SR5906 CE 141

SU7000 CE, CUL 143

SU8000 CE, CUL 143

SU9000 CE, CUL 143

TA3130 CE, CUL 171

TA3131 CE, CUL 171

TA3231 CE, CUL 172

TA3430 CE, CUL, EHEDG 172

TA3431 CE, CUL, EHEDG 172

TA3437 CE, EHEDG 172

TAA131 CE, CUL 172

TAA431 CE, CUL, EHEDG 173

TAD181 CE, CUL, EHEDG 173

TAD981 CE, CUL, EHEDG 173

TAP18A CE, EHEDG, FDA 173

TAP98A CE, EHEDG, FDA 173

TK6130 CE, CUL 169

TK6330 CE, CUL 169

TK7130 CE, CUL 169

TK7330 CE, CUL 169

TK7480 CE, CUL 169

TM0061 CUL, EHEDG 170

TM9550 CUL 170

TN2531 CE, CUL 169

TN7531 CE, CUL 169

TP3237 CE 170

TR2432 CE, CUL 170

TR7432 CE, CUL 170

TR8430 CE, CUL 169

TS2051 CUL 171, 172

TS2056 171, 172

TS2229 171

TS2251 171

TS2256 171

TS5051 CUL 171, 172

TT0061 CUL 172

TT1050 CUL 170

TT1061 CUL 172

TT1250 CUL 170

TT2050 CUL 170

TT2081 CUL 171

Orderno.

Approvals Cataloguepage

TT3250 CUL 170

TT5050 CUL 170

VE1001 CE, CUL 185

VE1101 CE, CUL 185

VE113A CE, IEC 185

VKV021 CE, CUL 185

VKV022 CE 185

VSA001 CE, CUL 186

VSA002 CE, CUL 186

VSA003 CE, CUL 187

VSE002 CE, CUL 186

VSE100 CE, CUL 186

16

Inductive sensors

Selection chart Page

Sensors for industrial applications, DC 19 - 20

Sensors for industrial applications, AC and AC/DC 20 - 21

Sensors with increased sensing range for industrial automation 21 - 22

Photoelectric sensors 23

Sensors for oils and coolants 23

Sensors for oils and coolants with ceramic sensing face 23

Sensors for mobile applications 24

Full-metal sensors with non-stick coating against weld spatter 24

Electromagnetic field immune sensors with correction factor K = 1 25

Electromagnetic field immune sensors 25

Full-metal sensors for hygienic and wet areas 25

Sensors for hygienic and wet areas with increased sensing range 25 - 27

Sensors with ATEX / IECex approval 1D / 1G / 2G 27

Switching amplifiers with ATEX / IECex approval 28

Sensors with ATEX approval 3D 28

Accessories 28 - 29

Wiring diagrams 30

Scale drawings - CAD download: www.ifm.com 31

17www.ifm.comwww.ifm.com

Inductive proximity sensors forall industries.

Wide choice of housing stylesand operating voltages.

High-quality housing materials.

Cylindrical housings from 3 to 34 mm diameter, various rectangular housings.

Large supporting range of mountingand wiring accessories.

Inductive sensors

In all automated processes sensors are absolutely necessary to provide the PLC withinformation. They supply the necessary signals on positions, limits or serve as pulsepick-ups for counting tasks or for monitoring rotational speed. Inductive and capaci-tive sensors are nowadays indispensable for industrial usage. As compared to me-chanical switches they offer ideal conditions: non-contact operation free from anywear and tear, high switching frequencies and accuracy. In addition, they are in-sensitive to vibration, dust and moisture. Inductive sensors detect all metals withoutcontact, capacitive sensors almost all solid and liquid media such as metal, glass,wood, plastic, water, oil, etc.

Operating principle of inductive sensors

Inductive sensors take advantage of the physical effect of the change in the qualityfactor in a resonant circuit caused by eddy current losses in conductive materials. Thisis how it works: A LC tuned circuit generates a high frequency electromagnetic field.This field is radiated from the active face of the sensor. If a conductive material entersthis field, eddy currents will be formed in accordance with the law of inductancewhich draw energy from the oscillator. This reduces the oscillation amplitude. Thechange is converted into a switching signal. The operating principle permits detec-tion of all metals irrespective of whether they are moving or not. The distance to theactive face at which an electrically conductive material causes a change of signal inthe sensor is called sensing range. The sensing range of an inductive sensor is definedby means of a target of mild steel (Fe 360). If the switch is damped by other metals,e.g. aluminium or copper, this is reduced. Using correction factors the user cancalculate the attainable sensing ranges.

Application sensors

Every application has its own requirements as regards the sensors to be used. Tem-perature shocks, mechanical influences or aggressive cleaning agents are just a fewof the possible environmental influences to which sensors are subjected. ifm elec-tronic therefore offers inductive sensors which have been developed for special appli-cations. This includes for example the use of selected housing materials such as stain-less steel, LCP, PEEK, PBT or Duroplast. An innovative, consistent sealing conceptfrom the sensor to the connector ensures ideal protection against ingress of mois-ture and aggressive media.

Typical application:Positioning sensing inautomation technolo-gy; proximity sensorsoperate reliably andwithout wear.

High frequencyelectromagnetic field:The inductive sensor

detects all metals.

Inductive sensors

18www.ifm.com

Sensors for industrial applications, DC

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

Cable 2 m · Output function · DC PNP · Wiring diagram no. 1

Ø 4 / L = 23 0.8 f stainless steel 10...30 IP65 2000 100 1 IZ5051

Ø 3 / L = 27 1 nf stainless steel 10...30 IP67 5000 100 2 IZ5048

Ø 4 / L = 27 1.5 nf stainless steel 10...30 IP67 1800 100 3 IZ5047

M5 / L = 23 0.8 f stainless steel 10...30 IP65 2000 100 4 IY5051

Ø 6.5 / L = 27 2 f high-grade st. steel 10...30 IP67 1500 100 5 IT5042

Ø 6.5 / L = 27 4 nf high-grade st. steel 10...30 IP67 500 100 6 IT5043

Cable 2 m · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 12

M8 / L = 37 3 f brass 10...30 IP67 1000 100 7 IE5343

M8 / L = 37 5 nf brass 10...30 IP67 700 100 8 IE5345

M8 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M8 / L = 40 3 f brass 10...30 IP67 1000 100 9 IE5338

M8 / L = 40 5 nf high-grade st. steel 10...30 IP67 700 100 10 IE5340

Cable 2 m · Output function · DC PNP · Wiring diagram no. 1

40 x 8 x 8 2.5 f brass 10...36 IP65 2000 250 11 IL5020

28 x 10 x 16 4 nf PBT 10...36 IP67 2000 250 12 IS5070

Cable 2 m · Output function · DC PNP/NPN · Wiring diagram no. 14

28 x 10 x 16 2 f PBT 5...36 IP67 2000 200 13 IS5026

Cable 2 m · Output function · DC PNP · Wiring diagram no. 1

40 x 12 x 26 2 f PBT 10...36 IP67 1400 250 14 IN5121

40 x 12 x 26 4 nf PBT 10...36 IP67 1300 250 14 IN5129

Inductive sensors

19www.ifm.com

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

Terminals · Output function · DC PNP · Wiring diagram no. 2

40 x 40 x 120 15 f PPE 10...36 IP65 350 250 15 IM5020

40 x 40 x 120 30 nf PPE 10...36 IP65 100 250 15 IM5046

Terminals · Output function · DC PNP/NPN · Wiring diagram no. 15

40 x 40 x 120 15 f PPE 10...55 IP65 > 350 400 15 IM5037

40 x 40 x 120 20 nf PPE 10...55 IP65 > 300 400 15 IM5038

Terminals · Output function · DC PNP · Wiring diagram no. 3

40 x 40 x 118 15 f PBT 10...60 IP67 150 200 16 IV5003

40 x 40 x 118 20 f PBT 10...60 IP67 150 200 17 IV5004

f = flush / nf = non flush

Sensors for industrial applications, AC and AC/DC

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection fAC / DC

[Hz]

IloadAC / DC

[mA]

Draw-ingno.

Orderno.

Cable 2 m · Output function · AC · Wiring diagram no. 4

M12 / L = 71 2 f brass 20...250 IP67 25 250 18 IF0005*

M12 / L = 71 4 nf brass 20...250 IP67 25 250 19 IF0007*

Cable 2 m · Output function · AC/DC · Wiring diagram no. 5

M18 / L = 80 5 f brass 20...250 IP67 25 / 50 350 / 100 20 IG0011*

M18 / L = 80 8 nf brass 20...250 IP67 25 / 50 350 / 100 21 IG0012*

M30 / L = 81 10 f brass 20...250 IP67 25 / 50 350 / 100 22 II0011*

M30 / L = 81 15 nf brass 20...250 IP67 25 / 50 350 / 100 23 II0012*

Terminals · Output function · AC/DC · Wiring diagram no. 6

40 x 40 x 120 15 f PPE 20...250 IP65 20 / 55 350 / 100 15 IM0011*

40 x 40 x 120 20 nf PPE 20...250 IP65 20 / 55 350 / 100 15 IM0010*

Inductive sensors

20www.ifm.com

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection fAC / DC

[Hz]

IloadAC / DC

[mA]

Draw-ingno.

Orderno.

1/2“ connector · Output function · AC/DC · Wiring diagram no. 7

40 x 40 x 66 35 nf PPE 20...250 IP67 20 / 50 350 / 100 24 IM0049*

M12 connector · Output function · AC/DC · Wiring diagram no. 7

40 x 40 x 66 20 f PPE 20...250 IP67 25 / 140 350 / 100 25 IM0054*

Terminals · Output function · AC/DC · Wiring diagram no. 16

105 x 80 x 40 60 nf modified PPE 20...250 IP65 4 350 / 100 26 ID0013*

f = flush / nf = non flush

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 2 A (fast acting). Recommendation: check the unit for reliable function after a shortcircuit.

Sensors with increased sensing range for industrial automation

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M12 / L = 45 4 f brass 10...36 IP67 700 100 27 IFS204

M12 / L = 50 7 nf brass 10...36 IP67 700 100 28 IFS205

M12 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M12 / L = 70 4 f brass 10...30 IP67 500 100 29 IFS208

M12 / L = 70 7 nf brass 10...30 IP67 500 100 30 IFS209

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M18 / L = 46 8 f brass 10...36 IP67 400 100 31 IGS204

M18 / L = 51 12 nf brass 10...36 IP67 300 100 32 IGS205

M12 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M18 / L = 70 8 f brass 10...30 IP67 400 100 33 IGS208

Inductive sensors

21www.ifm.com

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M18 / L = 70 12 nf brass 10...30 IP67 300 100 34 IGS209

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M30 / L = 50 15 f brass 10...36 IP67 100 100 35 IIS204

M30 / L = 50 22 nf brass 10...36 IP67 100 100 36 IIS205

M12 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M30 / L = 70 15 f brass 10...30 IP67 100 100 37 IIS206

M30 / L = 70 22 nf brass 10...30 IP67 100 100 38 IIS207

M12 connector · Output function · DC PNP · Wiring diagram no. 8

40 x 40 x 54 20 f PA (polyamide) 10...36 IP67 100 200 39 IM5115

40 x 40 x 54 35 nf PA (polyamide) 10...36 IP67 80 200 39 IM5116

40 x 40 x 54 40 nf PA (polyamide) 10...36 IP67 60 200 39 IM5117

M12 connector · Output function · DC PNP · Wiring diagram no. 9

40 x 40 x 54 20 f PA (polyamide) 10...36 IP67 100 200 39 IM5123

40 x 40 x 54 20 f PA (polyamide) 10...36 IP67 200 200 40 IM5124

40 x 40 x 54 40 nf PA (polyamide) 10...36 IP67 60 200 39 IM5136

40 x 40 x 54 40 nf PA (polyamide) 10...36 IP67 200 200 40 IM5126

92 x 80 x 40 50 f PPE 10...36 IP67 70 250 41 ID5058

M12 connector · Output function normally open / closed programmable) · DC PNP · Wiring diagram no. 8

105 x 80 x 40 60 nf PPE 10...36 IP67 100 250 42 ID5046

f = flush / nf = non flush

Inductive sensors

22www.ifm.com

Photoelectric sensors

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M12 / L = 63 50 f high-grade st. steel 10...30 IP68 / IP69K 1600 100 43 JAT201

f = flush / nf = non flush

Sensors for oils and coolants

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP/NPN · Wiring diagram no. 17

40 x 40 x 54 15 f PA (polyamide) 10...36 IP67 200 100 44 IM5127

f = flush / nf = non flush

Sensors for oils and coolants with ceramic sensing face

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M12 / L = 45 4 f brass 10...36 IP68 700 100 27 IFC206

M12 / L = 45 4 f brass 10...36 IP68 700 100 27 IFC204

M12 / L = 50 7 nf brass 10...36 IP68 700 100 28 IFC205

M18 / L = 46 8 f brass 10...36 IP68 400 100 31 IGC206

M18 / L = 46 8 f brass 10...36 IP68 400 100 31 IGC204

M18 / L = 51 12 nf brass 10...36 IP68 300 100 32 IGC205

M30 / L = 50 15 f brass 10...36 IP68 100 100 35 IIC200

M30 / L = 50 22 nf brass 10...36 IP68 100 100 36 IIC201

f = flush / nf = non flush

Inductive sensors

23www.ifm.com

Sensors for mobile applications

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M12 / L = 70 4 f high-grade st. steel 10...60 IP67 / IP69K 400 200 45 IFM205

M12 / L = 70 7 nf stainless steel 10...60 IP67 / IP69K 300 200 46 IFM206

M18 / L = 70 8 f stainless steel 10...60 IP67 / IP69K 200 200 47 IGM204

M18 / L = 70 12 nf stainless steel 10...60 IP67 / IP69K 200 200 48 IGM205

M30 / L = 70 12 f stainless steel 10...60 IP67 / IP69K 100 200 37 IIM208

M30 / L = 70 22 nf stainless steel 10...60 IP67 / IP69K 100 200 38 IIM209

f = flush / nf = non flush

Full-metal sensors with non-stick coating against weld spatter

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M8 / L = 60 2 f stainless steel 10...36 IP67 / IP68 100 100 49 IER200

M12 / L = 60 4 f high-grade st. steel 10...36 IP67 2 100 50 IFR200

M18 / L = 70 6 f high-grade st. steel 10...36 IP67 2 100 51 IGR200

M30 / L = 70 12 f high-grade st. steel 10...36 IP67 2 100 52 IIR200

f = flush / nf = non flush

Inductive sensors

24www.ifm.com

Electromagnetic field immune sensors with correction factor K = 1

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 9

40 x 40 x 54 20 f PA (polyamide) 10...36 IP67 200 200 40 IM5124

40 x 40 x 54 40 nf PA (polyamide) 10...36 IP67 200 200 40 IM5126

f = flush / nf = non flush

Electromagnetic field immune sensors

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

40 x 40 x 118 15 f modified PPE 10...60 IP67 50 200 53 IV5025

M12 connector · Output function · DC PNP · Wiring diagram no. 9

92 x 80 x 40 50 f PPE 10...36 IP67 70 250 41 ID5059

f = flush / nf = non flush

Full-metal sensors for hygienic and wet areas

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M12 / L = 60 3 f high-grade st. steel 10...36 IP68 / IP69K 100 100 50 IFT240

M18 / L = 70 5 f high-grade st. steel 10...36 IP68 / IP69K 100 100 51 IGT247

M30 / L = 70 10 f high-grade st. steel 10...36 IP68 / IP69K 50 100 52 IIT228

f = flush / nf = non flush

Sensors for hygienic and wet areas with increased sensing range

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M12 / L = 45 4 f high-grade st. steel 10...36 IP68 / IP69K 800 100 27 IFT203

M12 / L = 50 7 nf high-grade st. steel 10...36 IP68 / IP69K 800 100 54 IFT200

Inductive sensors

25www.ifm.com

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M12 / L = 70 4 f high-grade st. steel 10...36 IP68 / IP69K 500 100 29 IFT205

M12 / L = 70 7 nf high-grade st. steel 10...30 IP68 / IP69K 700 100 46 IFT202

Cable 6 m · Output function · DC PNP · Wiring diagram no. 1

M12 / L = 50 4 f high-grade st. steel 10...36 IP68 / IP69K 800 100 55 IFT206

M12 / L = 61 7 nf high-grade st. steel 10...36 IP68 / IP69K 800 100 56 IFT208

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M18 / L = 46 8 f high-grade st. steel 10...36 IP68 / IP69K 600 100 31 IGT203

M18 / L = 51 12 nf high-grade st. steel 10...36 IP68 / IP69K 300 100 57 IGT200

M12 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M18 / L = 70 8 f high-grade st. steel 10...30 IP68 / IP69K 400 100 47 IGT205

M18 / L = 70 12 nf high-grade st. steel 10...30 IP68 / IP69K 300 100 58 IGT202

Cable 6 m · Output function · DC PNP · Wiring diagram no. 1

M18 / L = 57 8 f high-grade st. steel 10...36 IP68 / IP69K 600 100 59 IGT206

M18 / L = 62 12 nf high-grade st. steel 10...36 IP68 / IP69K 300 100 60 IGT208

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M30 / L = 50 14 f high-grade st. steel 10...36 IP68 / IP69K 50 100 35 IIT205

M30 / L = 50 22 nf high-grade st. steel 10...36 IP68 / IP69K 100 100 61 IIT200

M12 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M30 / L = 70 14 f high-grade st. steel 10...36 IP68 / IP69K 50 100 37 IIT204

Inductive sensors

26www.ifm.com

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · 3-wire DC PNP; 2-wire DC PNP/NPN · Wiring diagram no. 13

M30 / L = 70 22 nf high-grade st. steel 10...36 IP68 / IP69K 100 100 38 IIT202

1/2“ connector · Output function · AC/DC · Wiring diagram no. 10

M30 / L = 70 22 nf high-grade st. steel 20...140 IP68 / IP69K 25 / 100 200 62 IIT002

Cable 6 m · Output function · DC PNP · Wiring diagram no. 1

M30 / L = 59 22 nf high-grade st. steel 10...36 IP68 / IP69K 100 100 63 IIT207

M30 / L = 59 14 f high-grade st. steel 10...36 IP68 / IP69K 100 100 64 IIT209

f = flush / nf = non flush

Sensors with ATEX / IECex approval 1D / 1G / 2G

Type Dimensions

[mm]

Sensingrange[mm]

Material Unom.at 1 KΩ

[V]

Ub

[V]

Internalcapacit.

[nF]

Internalinductance

[μH]

f

[Hz]

Draw-ingno.

Orderno.

M12 connector · Output function · Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW · Wiring diagram no. 11

M12 / L = 45 4 f brass 8.2 DC 7.5...30 210 115 700 27 NF501A

M12 / L = 50 7 nf brass 8.2 DC 7.5...30 210 145 700 28 NF500A

M18 / L = 46 8 f brass 8.2 DC 7.5...30 200 190 400 31 NG501A

M18 / L = 51 12 nf brass 8.2 DC 7.5...30 200 85 300 32 NG500A

M30 / L = 50 15 f brass 8.2 DC 7.5...30 230 210 100 35 NI501A

M30 / L = 50 22 nf brass 8.2 DC 7.5...30 250 120 100 36 NI500A

f = flush / nf = non flush

Inductive sensors

27www.ifm.com

Switching amplifiers with ATEX / IECex approval

Type Ub

[V]

Power / currentconsumption[VA] / [mA]

f

[Hz]

Ta

[°C]

Output Protection Draw-ingno.

Orderno.

24 / < 50 5000 -20...602 transistor outputs PNP (100 mA, short-

circuit protection)IP20 65 N0531A

24 / < 50 5000 -20...602 outputs (optocoupler, bipolar, 100 mA,

short-circuit protection)IP20 65 N0532A

24 / < 50 5000 -20...602 transistor outputs PNP (100 mA, short-

circuit protection)IP20 65 N0534A

Sensors with ATEX approval 3D

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP · Wiring diagram no. 8

M12 / L = 60 3 f high-grade st. steel 10...36 IP67 100 100 50 IF502A

M18 / L = 70 5 f high-grade st. steel 10...36 IP67 100 100 51 IG509A

M30 / L = 70 10 f high-grade st. steel 10...36 IP67 50 100 66 II501A

M12 connector · Output function · DC PNP · Wiring diagram no. 9

40 x 40 x 54 40 nf PA (polyamide) 10...30 IP5x 100 200 39 IM503A

40 x 40 x 54 20 f PA (polyamide) 10...30 IP5x 100 200 39 IM504A

f = flush / nf = non flush

Accessories

Type Description Orderno.

Angle bracket · for type M8 · Housing materials: stainless steel E10734

Angle bracket · for type M12 · Housing materials: stainless steel E10735

Angle bracket · for type M18 · Housing materials: stainless steel E10736

Angle bracket · for type M30 · Housing materials: stainless steel E10737

Mounting clamp · Ø 8 mm · with end stop · for type M8 · Housing materials: PC E11521

Inductive sensors

28www.ifm.com

Type Description Orderno.

Mounting clamp · Ø 34 mm · Housing materials: PBT E10017

Mounting clip · Ø 12 mm · for smooth body switches - Ø 12 mm · Form V · Housing materials: V4A E11530

Mounting clip · Ø 18 mm · for smooth body switches - Ø 18 mm · Form V · Housing materials: V4A E11531

Mounting clip · Form O · for type M12 · Housing materials: stainless steel E11533

Mounting clip · Form O · for type M18 · Housing materials: stainless steel E11534

Mounting clamp · Ø 12 mm · with end stop · for type M12 · Housing materials: PC E11047

Mounting clamp · Ø 18 mm · with end stop · for type M18 · Housing materials: PC E11048

Mounting set · Ø 18.5 mm · Clamp mounting · free-standing M10 · for type OG, IG, KG · Housing materials: clamp: diecast zinc /fixture: steel

E20718

Mounting set · Ø 12.2 mm · Clamp mounting · free-standing M8 · for type OF, IF · Housing materials: fixture: stainless steel 316Ti /1.4571 / clamp: diecast zinc

E20860

Mounting set · Ø 12.2 mm · Clamp mounting · free-standing M8 · for type OF, IF · Housing materials: fixture: stainless steel 316Ti /1.4571 / clamp: stainless steel

E20861

Mounting set · Ø 18.5 mm · Clamp mounting · free-standing M10 · for type OG, IG, KG · Housing materials: fixture: stainless steel316Ti / 1.4571 / clamp: stainless steel

E20870

Mounting set · Ø 30.2 mm · Clamp mounting · free-standing M12 · for type OI, II, KI · Housing materials: fixture: stainless steel316Ti / 1.4571 / clamp: diecast zinc

E20873

Mounting set · Ø 30.2 mm · Clamp mounting · free-standing M12 · for type OI, II, KI · Housing materials: fixture: stainless steel316Ti / 1.4571 / clamp: stainless steel

E20874

Plastic nut for flow plate · M18 x 1 · Housing materials: POM E19503

Inductive sensors

29www.ifm.com

Wiring diagrams

1

BN

BK

BU

L+

L

2

/ L+

L

13

/2 4

3

L

L+4

2

1

32:4:

4

BN

BU

L1

N

5

BN

BU

L+L1

LN

6

/1 3

/2 4

L1L+

LN

7

1

3

2

L1L+

LN

8

L+

L

1

4

3

9

4

L

L+1

2

32:4:

10

3

2

L1

N

L+

L

11

L+

L2

1

1

1: connection to NAMUR-amplifier

12

L+

L

BN

BK

BU

L+

L

BN

BK

13

L+

L

1

4

L+

L

1

4

3

14

WH

BK

L+

L L

BK

WH

L+

15

L+

L

/1 3

/2 4

L+

L/1 3

/2 4

16

2

4

3

1

5

AC;DC NPN

L+N

LL1

2

4

3

1

5

AC;DC NPN

L+N

LL1

2

4

3

1

5

DC PNP

L+

L

2

4

3

1

5

DC PNP

L+

L

17

L+

L1

4L+

L

1

4

Inductive sensors

30www.ifm.com

Scale drawings - CAD download: www.ifm.com

1

LED

2316 4

2

LED

2717 3

3

LED

2715,4 4

4

16

LED

1823

M5x

0,5

2,7

8

5

LED

3,5 27 6,5

6

LED 8

3,5

27

6,5

7

35

LED

M8x

1

413

2

8

27

LED

M8x

1

413

82

9

4

13

28,5

40

M8x

1

LED 4 x 90°

M8x

1

32,5

10

23

40

M8x

1

LED 4 x 90°

4

13

M8x

1

832,5

11

20 105M3

8

LED

40

520

IL 5003

4

IL 50021

1: sensing face

12

10,2

27,8

5,6

1622

,2

2,75

3,1

3,5

2,83,1

LED10,4

8

13

10,2

27,8

LED

5,6

165,1

22,2

2,75

3,1

3,5

2,83,1

LED

10,4

Inductive sensors

31www.ifm.com

Scale drawings - CAD download: www.ifm.com

14

406

12LED

4

2613

32

3,2 45

LED

3,2

18

1610

1

1: threaded insert M3, depth 5.8 mm, max. tightening torque 1.2Nm (screw fixing class 8.8) when brass insert in contact with counter-part.

15

40

10,4

45,6

LED

32

5,3

30

61,5

77

5,1

121101

LED

27

16

40

13

7,35,3

46

30

60

LED58

5,3

40118

LED

17

7,35,3

46

LED

30

60

137

LED58

5,3

40118

LED

29

40

18

9

18 7160

50

M12

x1

LED 174

19

9

18 716046

M12

x1

LED 174

4

20

24LED

801869

58

M18

x1

4

9

21

24LED

80186950

M18

x1

4

9

8

22

36

8167

59

5

M30

x1,5

9

18

LED

23

8167

5

1544

36

M30

x1,5

9

18

LED

Inductive sensors

32www.ifm.com

Scale drawings - CAD download: www.ifm.com

24

40

LED

4661

30 20

5,4

105,

4 6

8,5

33

1/2"

20U

NF

2ALS

100

4066

17

34

25

40

M12

x1

4066

17

34

LED

4661

30 20

5,4

105,

4 6

16

33

26

105

80

40

7,565

65

5,59,3 40

12

2718

LEDpot.

16

27

453432

M12

x1

174

M12

x1

LED 4 x 90°

28

32

M12

x1

174

5

M12

x1

3950

LED 4 x 90°

29

LED 4 x 90°

5970

50

M12

x1

174

M12

x1

30

45

M12

x1

174

5

M12

x1

5970

LED 4 x 90°

31

M18

x1

M12

x1

3033

4635

424LED 4 x 90°

32

M18

x1

M12

x1

2538

5140

424

10

LED 4 x 90°

33

M18

x1

M12

x1

4956,5

7059

424LED 4 x 90°

Inductive sensors

33www.ifm.com

Scale drawings - CAD download: www.ifm.com

34

M18

x1

M12

x1

4058

70

LED 4 x 90°

60

10

424

35

39

33

M30

x1,5

37

50

M12

x1

LED 4 x 90° 5 36

36

39

19

M30

x1,5

37

50

M12

x1

LED 4 x 90° 5

15

36

37

59

53

M30

x1,5

57

70

M12

x1

LED 4 x 90° 536

38

LED 4 x 90°

59

38

M30

x1,5

5

57

70

36

M12

x1

15

39

40

66

40

54

M12

x130

30 2

2

1

46

46

5,5

5,5

29,5

1: LED yellow, 2: LED green

40

40

66

40

54

M12

x130

30 2

5,5

5,5

1

2

46

46

29,5

1: LED yellow, 2: LED green

41

92

80

40

7,565

65

5,59,3

M12

x1

112

40

LED171

20

1: mounting on DIN rail

Inductive sensors

34www.ifm.com

Scale drawings - CAD download: www.ifm.com

42

105

80

40

7,565

65

5,59,3

M12

x1

123

4012

2718

LEDpot.

16

43

M12

x1

174

M12

x1

5263

LED 4 x 90°

43

44

40

66

40

54

M12

x130

30 2

46

46

5,5

5,5

LED

29,5

45

5950

M12

x1

174

M12

x1

LED

70

46

45

M12

x1

174

5

M12

x1

5970

LED

47

M18

x1

M12

x1

5057

7059

424LED 4 x 90°

48

M18

x1

M12

x1

4057

70

LED 4 x 90°

59

10

424

49

M8x

1

4

13M

12x1

6049

33

LED 4 x 90°

50

4940

M12

x1

174

M12

x1

LED 4 x 90°

60

51

5957

50

M18

x1

4

M12

x1

70

24LED 4 x 90°

52

58

50

M30

x1,5

5

57

70

36

M12

x1

LED 4 x 90°

Inductive sensors

35www.ifm.com

Scale drawings - CAD download: www.ifm.com

53

40118

LEDM

12x1

139

13

7,35,3

4630

60

LED58

5,3

40

54

32

M12

x1

174

5

M12

x1

3950

LED 4 x 90°

55

5037

29

M12

x1

174

LED

56

5

614428

M12

x1

LED 4 x 90° 174

5

57

M18

x1

M12

x1

2538

5140

424

10

LED 4 x 90°

58

M18

x1

M12

x1

3956

70

LED 4 x 90°

59

10

424

59

5739,5

2933

LED4 x 90°

M18

x1

424

5

60

6244,5

24

LED4 x 90°

38

M18

x1

424

10

61

39

18

M30

x1,5

37

50

M12

x1LED 4 x 90° 5

15

36

62

38

M30

x1,5

57

70

LED4 x 90°

536

15

59

1/2"

-20U

NF-

2A

63

16

M30

x1,5

1535

5

42

LED 4 x 90°

59

5 36

64

31

M30

x1,5

35

5

42

LED 4 x 90°

59

365

Inductive sensors

36www.ifm.com

Scale drawings - CAD download: www.ifm.com

65

112

35,5

20

120

LED

1

1: Combicon plug with screw terminals (optional)

66

58

50

M30

x1,5

5

57

70

36

M12

x1

LED 4 x 90°

Inductive sensors

37www.ifm.com

38

Capacitive sensors

Selection chart Page

Sensors for industrial applications, DC 41

Sensors for industrial applications, AC and AC/DC 41 - 42

Sensors for the detection of conductive media through a wall 42

Sensors for the detection of granulates 42

Sensors for the detection of granulates 43

Sensors with ATEX approval 43

Switching amplifiers with ATEX approval 43

Accessories 43 - 45

Wiring diagrams 45

Scale drawings - CAD download: www.ifm.com 46

39www.ifm.comwww.ifm.com

Capactive sensors for detection ofnon-metalic objects.

Sensing range adjustable by means of a potentiometer.

Plastic or metal housing for different applications.

Housing styles from M12 cylindricalto 105 x 80 mm block.

Assortment of tank and sight glassmounting acccessories.

Capacitive sensors

Capacitive sensors are used for the non-contact detection of any objects. In contrastto inductive sensors, which only detect metallic objects, capacitive sensors can alsodetect non-metallic materials. Typical applications are in the wood, paper, glass,plastic, food and chemical industries. In a packaging system, capacitive sensors moni-tor that the contents of a cardboard box is complete, for example, or check the pres-ence of non-metallic caps. Another application is to monitor the conveying of sheetsof glass on a roller conveyor.

Operating principle

The capacitance between the active electrode of the sensor and the electrical earthpotential is evaluated. An approaching object influences the electrical alternatingfield between these two “capacitor plates” and, consequently, the capacitance. Thisapplies to metallic and non-metallic objects. By means of the potentiometer or thepushbutton the user can set the sensitivity.

Increased noise immunity

When detecting objects, very small changes in capacitance must be evaluated andconverted into switching signals. This makes high requirements for the electronics.The sensors must be designed so that they are insensitive to fluctuations of theparasitic basic capacitances, as these can amount to a multiple of the change incapacitance to be measured. Moreover, the sensors must be insensitive to electro-magnetic interference which typically occur in the application area.

ifm electronic has developed future-oriented solutions to meet the high sensorrequirements. A patented circuit concept efficiently prevents the mentioned pro-blems and ensures reliable functioning for all relevant noise parameters.

Not only metal: Capacitive sensorsdetect almost allmaterials, herefor example a login a saw mill.

Capacitive sensors

40www.ifm.com

Sensors for industrial applications, DC

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

Cable 2 m · Output function · DC PNP · Wiring diagram no. 1

M30 / L = 81 15 nf PBT 10...36 IP65 40 250 1 KI5002

Cable 2 m · Output function · DC PNP · Wiring diagram no. 2

M30 / L = 81 15 nf PBT 10...36 IP65 40 250 1 KI5001

M12 connector · Output function · DC PNP · Wiring diagram no. 3

M30 / L = 90 8 f high-grade st. steel 10...36 IP65 / IP67 10 100 2 KI5085

M30 / L = 90 15 nf high-grade st. steel 10...36 IP65 / IP67 10 100 3 KI5087

M12 connector · Output function · DC PNP/NPN · Wiring diagram no. 9

M30 / L = 90 8 f high-grade st. steel 10...36 IP65 / IP67 10 100 2 KI5084

Terminals · Output function · DC PNP · Wiring diagram no. 10

105 x 80 x 40 60 nf modified PPO 10...36 IP65 10 250 4 KD5018

f = flush / nf = non flush

Sensors for industrial applications, AC and AC/DC

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection fAC / DC

[Hz]

IloadAC / DC

[mA]

Draw-ingno.

Orderno.

Cable 2 m · Output function · AC/DC · Wiring diagram no. 4

M18 / L = 84 8 nf PBT 20...250 IP67 25 / 50 350 / 100 5 KG0009*

Cable 2 m · Output function · AC/DC · Wiring diagram no. 5

M18 / L = 84 8 nf PBT 20...250 IP67 25 / 50 350 / 100 5 KG0010*

Cable 2 m · Output function · AC/DC · Wiring diagram no. 4

M30 / L = 81 15 nf PBT 20...250 IP65 25 / 40 250 1 KI0016*

Capacitive sensors

41www.ifm.com

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection fAC / DC

[Hz]

IloadAC / DC

[mA]

Draw-ingno.

Orderno.

Cable 2 m · Output function · AC/DC · Wiring diagram no. 5

M30 / L = 81 15 nf PBT 20...250 IP65 25 / 40 250 1 KI0020*

Terminals · Output function · AC/DC · Wiring diagram no. 11

105 x 80 x 40 60 nf modified PPO 20...250 IP65 10 250 4 KD0009*

f = flush / nf = non flush

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 2 A (fast acting). Recommendation: check the unit for reliable function after a shortcircuit.

Sensors for the detection of conductive media through a wall

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

Cable 2 m · Output function · 1x open collector with automatic load detection (DC PNP or DC NPN) · Wiring diagramno. 12

20 x 14 x 48 12 nf PBT 10...36 IP65 / IP67 10 100 6 KQ6001

Cable with connector 0.04 m · Output function · 1x open collector with automatic load detection (DC PNP or DC NPN)· Wiring diagram no. 9

20 x 14 x 48 12 nf PBT 10...36 IP65 / IP67 10 100 6 KQ6003

Cable with connector 0.1 m · Output function · 1x open collector DC PNP · Wiring diagram no. 3

20 x 14 x 48 12 nf PBT 10...36 IP65 / IP67 10 100 6 KQ6005

f = flush / nf = non flush

Sensors for the detection of granulates

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP/NPN · Wiring diagram no. 9

M18 / L = 87 12 nf PBT 10...36 IP65 / IP67 10 200 7 KG5065

M30 / L = 90 20 nf PBT 10...36 IP65 / IP67 10 200 8 KI5082

f = flush / nf = non flush

Capacitive sensors

42www.ifm.com

Sensors for the detection of granulates

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection f

[Hz]

Iload

[mA]

Draw-ingno.

Orderno.

1/2“ UNF-Connector · Output function · AC/DC · Wiring diagram no. 6

M30 20 nf PBT 20...250 IP65 / IP67 10 150 9 KI0054*

f = flush / nf = non flush

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 2 A (fast acting). Recommendation: check the unit for reliable function after a shortcircuit.

Sensors with ATEX approval

Type Dimensions

[mm]

Sensingrange[mm]

Material Unom.at 1 KΩ

[V]

Ub

[V]

Internalcapacit.

[nF]

Internalinductance

[μH]

f

[Hz]

Draw-ingno.

Orderno.

Cable 2 m · Output function · Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P =120 mW · Wiring diagram no. 7

M30 / L = 81 15 nf PBT 8.2 DC 7.5...15 375 1 40 1 KI5030

Cable 2 m · Output function · Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P =120 mW · Wiring diagram no. 8

M34 / L = 92 15 nf brass 8.2 DC 7.5...15 375 1 40 10 KX5001

f = flush / nf = non flush

Switching amplifiers with ATEX approval

Type Ub

[V]

Power / currentconsumption[VA] / [mA]

f

[Hz]

Ta

[°C]

Output Protection Draw-ingno.

Orderno.

24 / < 50 5000 -20...602 transistor outputs PNP (100 mA, short-

circuit protection)IP20 11 N0531A

24 / < 50 5000 -20...602 outputs (optocoupler, bipolar, 100 mA,

short-circuit protection)IP20 11 N0532A

24 / < 50 5000 -20...602 transistor outputs PNP (100 mA, short-

circuit protection)IP20 11 N0534A

Accessories

Type Description Orderno.

Mounting clamp · Ø 34 mm · Housing materials: PBT E10017

Angle bracket · for type M12 · Housing materials: stainless steel E10735

Capacitive sensors

43www.ifm.com

Type Description Orderno.

Angle bracket · for type M18 · Housing materials: stainless steel E10736

Angle bracket · for type M30 · Housing materials: stainless steel E10737

Locknut · G 1¼ · for mounting adapter · Housing materials: PVDF E11030

Locknut · G 1½ · for mounting adapter · Housing materials: POM E11031

Locknut · G 1½ · for mounting adapter · Housing materials: PVDF E11032

Mounting adapter · M30 x 1.5 - G 1½ · Housing materials: POM / EPDM E11033

Mounting adapter · M30 x 1.5 - G 1½ · Housing materials: PVDF / EPDM E11034

Mounting adapter · M30 x 1.5 - G 1¼ · Housing materials: PVDF / EPDM E11036

Protective cover · G 1¼ · for mounting adapter · Housing materials: PES black transparent E11078

Mounting set · Ø 18.5 mm · Clamp mounting · free-standing M10 · for type OG, IG, KG · Housing materials: clamp: diecast zinc /fixture: steel

E20718

Mounting set · Ø 18.5 mm · Clamp mounting · free-standing M10 · for type OG, IG, KG · Housing materials: fixture: stainless steel316Ti / 1.4571 / clamp: stainless steel

E20870

Mounting set · Ø 30.2 mm · Clamp mounting · free-standing M12 · for type OI, II, KI · Housing materials: fixture: stainless steel316Ti / 1.4571 / clamp: diecast zinc

E20873

Mounting set · Ø 30.2 mm · Clamp mounting · free-standing M12 · for type OI, II, KI · Housing materials: fixture: stainless steel316Ti / 1.4571 / clamp: stainless steel

E20874

Mounting adapter · M18 x 1 - G ¾ · Housing materials: PVDF E43901

Capacitive sensors

44www.ifm.com

Type Description Orderno.

Locknut · G ¾ · for mounting adapter · Housing materials: PVDF E43903

Mounting adapter for free-standing mounting · for type KQ · Housing materials: adapter: PBT / inserts: brass / screw: steel galvanised· Pack quantity: 1

E12153

Wiring diagrams

1

BN

BK

BU

L+

L

2

BN

BK

BU

L+

L

3

L+

L

1

4

3

4

BN

BU

L+L1

LN

5

BN

BU

L+L1

LN

6

2

3

L1

N

L+

L

7

+BN

BU

8

BN

GN/YE

BU+

9

L+

L

1

4

3

L+

L

1

4

3

10

2

4

3

1

5

L+

L

2

4

3

1

5

L+

L

11

2

4

3

1

5

AC;DC NPN

L+N

LL1

2

4

3

1

5

AC;DC NPN

L+N

LL1

2

4

3

1

5

DC PNP

L+

L

2

4

3

1

5

DC PNP

L+

L

12

L

L+BN

BK

BU L

L+BN

BK

BU

Capacitive sensors

45www.ifm.com

Scale drawings - CAD download: www.ifm.com

1

36

8159

5

M30

x1,5

9

18pot.LED

2

60

M30

x1,5

7790

LED (4 x 90°) 5

M12

x 1

361

1: Programming buttons

3

60

M30

x1,5

7790

LED (4 x 90°) 5

M12

x 1

361

15

1: Programming buttons

4

105

80

40

7,565

65

5,59,3 40

12

2718

LEDpot.

16

5

24

58

4

84

M18

x1

pot.LED LEDpot.

6

3,2

48

3343,7

2

5,5 3

13,4

14

20

121

1: Programming buttons, 2: sensing face

7

24

7756

M18

x1

4

M12

x1

87

1 2

1: LED ring, 2: Programming buttons

8

61

M30

x1,5

8090

5

M12

x 1

3621

1: LED ring, 2: Programming buttons

9

6180

90

5

M30

3621

1/2"

UN

F

1: LED ring, 2: Programming buttons

10

822040

M34

x1,5

10

541

LEDpot.

Capacitive sensors

46www.ifm.com

Scale drawings - CAD download: www.ifm.com

11

112

35,5

20

120

LED

1

1: Combicon plug with screw terminals (optional)

Capacitive sensors

47www.ifm.com

48

Cylinder sensors

Selection chart Page

T-slot sensors for industrial applications 51

T-slot reed sensors for industrial applications 51

T-slot sensors for hygienic and wet ares 52

Sensors for short-stroke cylinders 52

Sensors for short-stroke cylinders for hygienic and wet areas 52

Non flush C-slot sensors for industrial applications 52 - 53

Accessories 53 - 54

Scale drawings - CAD download: www.ifm.com 55

Wiring diagrams 55

49www.ifm.comwww.ifm.com

Self-clamping fixture for easy adjustment and quick mounting.

Convenient: can be easily inserted into the slot from the top.

Suitable for almost all C and T slots.

Unit versions available with connection cable and M8 / M12 cable plug.

Wide selection of adapter accessories.

Cylinder sensors

Cylinder sensors are used for position detection of pistons in pneumatic cylinders.They are directly mounted onto the cylinder. The ring magnet attached to the pistonis sensed through the housing wall of non-magnetisable material (e.g. aluminium,brass or stainless steel). ifm electronic offers a standard solution for different cylindertypes and manufacturers.

Operating principle

ifm’s cylinder sensors use state-of-the-art GMR and AMR technology: A GMRelement is made up of extremely thin magnetic layers, each separated by a non-magnetic layer. Without external field they align in an antiparallel manner whichresults in a defined electrical resistance. If these layers are exposed to a magneticfield, the magnetic layers align in a parallel manner. This results in a large change inresistance that is converted into a switching signal by the internal electronics.

An AMR element consists of thin ferromagnetic layers. Electrical resistance is highestwithout external magnetic fields. The effect of a magnetic field reduces resistance.This change is converted into a switching signal by the internal electronics. Advan-tage: this method enables exact measurement of even very small changes of themagnetic field where space is extremely limited. This results in a smaller hysteresisand a short travel distance. So, the sensors can be used wherever exact positioning isrequired (e.g. short-stroke cylinder).

Response sensitivity

The response sensitivity applies equally to either magnetic polarity and without exter-nal field influence. The magnetic flux density in most pneumatic cylinders is between5 and 25 millitesla (mT). ifm electronic’s cylinder sensors are factory set so that theydetect these magnetic fields safely.

Travel distance

The travel distance describes the section which is covered by the magnet in thesensing zone. It depends on the strength of the magnet. The short response times ofthe sensors allow very high travel speeds.

Position sensing:Cylinder sensorsmonitor the positionof the piston in apneumatic cylinder.

Cylinder sensors

50www.ifm.com

T-slot sensors for industrial applications

Type Dimensions

[mm]

Material Ub

[V]

f

[Hz]

Protection Iload

[mA]

Ta

[°C]

Draw-ingno.

Orderno.

Cable with connector 0.3 m · Output function · DC PNP · Wiring diagram no. 1

25 x 5 x 6.5 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 1 MK5101

25 x 5 x 6.5 PA (polyamide) 10...30 > 10000 IP67 200 -25...85 1 MK5106

25 x 5 x 6.5 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 2 MK5102

25 x 5 x 6.5 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 3 MK5107

Cable 2 m · Output function · DC PNP · Wiring diagram no. 2

25 x 5 x 6.5 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 4 MK5100

Cable 2 m · Output function · DC PNP/NPN · Wiring diagram no. 3

25 x 5 x 6.5 PA (polyamide) 10...30 4000 IP67 100 -25...85 4 MK5103

Cable with connector 0.3 m · Output function · DC PNP · Wiring diagram no. 1

25 x 5 x 6.5 PA (polyamide) 10...30 > 10000 IP67 200 -25...85 3 MK5108

Cable with connector 0.3 m · Output function · DC PNP/NPN · Wiring diagram no. 4

25 x 5 x 6.5 PA (polyamide) 10...30 4000 IP67 100 -25...85 1 MK5104

T-slot reed sensors for industrial applications

Type Dimensions

[mm]

Material Ub

[V]

f

[Hz]

Protection Iload

[mA]

Ta

[°C]

Draw-ingno.

Orderno.

Cable 2 m · Output function · AC/DC PNP/NPN · Wiring diagram no. 5

30.5 x 5 x 6.5 PA (polyamide) 5...120 1000 IP67 100 -25...70 5 MR0100*

Cable with connector 0.3 m · Output function · AC/DC PNP/NPN · Wiring diagram no. 6

30.5 x 5 x 6.5 PA (polyamide) 5...60 1000 IP67 100 -25...70 6 MR0107*

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 0,175 A (fast acting). Recommendation: check the unit for reliable function after ashort circuit.

Cylinder sensors

51www.ifm.com

T-slot sensors for hygienic and wet ares

Type Dimensions

[mm]

Material Ub

[V]

f

[Hz]

Protection Iload

[mA]

Ta

[°C]

Draw-ingno.

Orderno.

Cable 2 m · Output function · DC PNP · Wiring diagram no. 2

25 x 5 x 6.5 PA (polyamide) 10...30 > 10000 IP67 / IP69K 100 -25...85 4 MK5110

Cable with connector 0.3 m · Output function · DC PNP · Wiring diagram no. 1

25 x 5 x 6.5 PA (polyamide) 10...30 > 10000 IP67 / IP69K 100 -25...85 7 MK5111

Sensors for short-stroke cylinders

Type Dimensions

[mm]

Material Ub

[V]

f

[Hz]

Protection Iload

[mA]

Ta

[°C]

Draw-ingno.

Orderno.

Cable 2 m · Output function · DC PNP · Wiring diagram no. 2

25 x 5 x 6.5 PA (polyamide) 10...30 > 6000 IP67 100 -25...85 8 MK5140

Cable with connector 0.3 m · Output function · DC PNP · Wiring diagram no. 1

25 x 5 x 6.5 PA (polyamide) 10...30 > 6000 IP67 100 -25...85 9 MK5138

25 x 5 x 6.5 PA (polyamide) 10...30 > 6000 IP67 100 -25...85 10 MK5139

Sensors for short-stroke cylinders for hygienic and wet areas

Type Dimensions

[mm]

Material Ub

[V]

f

[Hz]

Protection Iload

[mA]

Ta

[°C]

Draw-ingno.

Orderno.

Cable with connector 0.3 m · Output function · DC PNP · Wiring diagram no. 1

25 x 5 x 6.5 PA (polyamide) 10...30 > 6000 IP67 / IP69K 100 -25...85 11 MK5157

Non flush C-slot sensors for industrial applications

Type Dimensions

[mm]

Material Ub

[V]

f

[Hz]

Protection Iload

[mA]

Ta

[°C]

Draw-ingno.

Orderno.

Cable 2 m · Output function · DC PNP · Wiring diagram no. 2

17.5 x 2.8 x 7.7 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 12 MK5300

Cable 2 m · Output function · DC NPN · Wiring diagram no. 7

17.5 x 2.8 x 7.7 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 12 MK5306

Cylinder sensors

52www.ifm.com

Type Dimensions

[mm]

Material Ub

[V]

f

[Hz]

Protection Iload

[mA]

Ta

[°C]

Draw-ingno.

Orderno.

Cable with connector 0.3 m · Output function · DC PNP · Wiring diagram no. 1

17.5 x 2.8 x 7.7 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 13 MK5301

Cable with connector 0.3 m · Output function · DC NPN · Wiring diagram no. 8

17.5 x 2.8 x 7.7 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 13 MK5307

Cable with connector 0.3 m · Output function · DC PNP · Wiring diagram no. 1

17.5 x 2.8 x 7.7 PA (polyamide) 10...30 > 10000 IP67 100 -25...85 14 MK5302

Accessories

Type Description Orderno.

Fixing strap for clean-line cylinders · Piston diameter · Ø 8...12 mm · Piston diameter 8...12 mm · for type MKT · Housing materials:stainless steel

E11816

Fixing strap for clean-line cylinders · Piston diameter · Ø 16...20 mm · Piston diameter 16...20 mm · for type MKT · Housingmaterials: adapter: PA / Fixing strap: stainless steel

E11817

Fixing strap for clean-line cylinders · Piston diameter · Ø 25...32 mm · Piston diameter 25...32 mm · for type MKT · Housingmaterials: adapter: PA / Fixing strap: stainless steel

E11818

Fixing strap for clean-line cylinders · Piston diameter · Ø 40 mm · Piston diameter 40 mm · for type MKT · Housing materials:adapter: PA / Fixing strap: stainless steel

E11819

Fixing strap for clean-line cylinders · Piston diameter · Ø 50 mm · Piston diameter 50 mm · for type MKT · Housing materials:adapter: PA / Fixing strap: stainless steel

E11820

Fixing strap for clean-line cylinders · Piston diameter · Ø 63 mm · Piston diameter 63 mm · for type MKT · Housing materials:adapter: PA / Fixing strap: stainless steel

E11821

Fixing strap for clean-line cylinders · Piston diameter · Ø 80 mm · Piston diameter 80 mm · for type MKT · Housing materials:adapter: PA / Fixing strap: stainless steel

E11822

Fixing strap for clean-line cylinders · Piston diameter · Ø 100 mm · Piston diameter 100 mm · for type MKT · Housing materials:adapter: PA / Fixing strap: stainless steel

E11823

Adapter for clean-line cylinders · for types MKT (T-slot cylinder sensors) · Housing materials: stainless steel E11877

Cylinder sensors

53www.ifm.com

Type Description Orderno.

Adapter for tie rod / integrated profile cylinders · for types MKT (T-slot cylinder sensors) · Clamping range 5...11 mm · Housingmaterials: aluminium / screw: stainless steel

E11797

Adapter for tie rod / integrated profile cylinders · for types MKT (T-slot cylinder sensors) · Clamping range 9...15 mm · Housingmaterials: aluminium / screw: stainless steel

E11799

Adapter for tie rod / integrated profile cylinders · for types MKT (T-slot cylinder sensors) · Clamping range 14...20 mm · Housingmaterials: aluminium / screw: stainless steel

E11801

Adapter for trapezoidal slot cylinders · for types MKT (T-slot cylinder sensors) · Housing materials: aluminium alloy / set screw:stainless steel

E11796

T-slot adapter for C-slot sensor · for types MKC (C-slot cylinder sensor) for installation in T-slot cylinders · for types MKC · (height 5mm) · Housing materials: diecast zinc / fixing element: stainless steel

E11928

T-slot adapter for C-slot sensor · for types MKC (C-slot cylinder sensor) for installation in T-slot cylinders · for types MKC · (height 7.7mm) · Housing materials: diecast zinc / fixing element: stainless steel

E11914

T-slot cylinder memorisation block · for types MKT (T-slot cylinder sensors) · Housing materials: PA / stainless steel E11798

C-slot cylinder memorisation block · for types MKC (C-slot cylinder sensors) · Housing materials: PA / stainless steel E12004

Clip · for types MKT (T-slot cylinder sensors) · Piston diameter 16 mm · Housing materials: POM / fixture: aluminium / screw: stainlesssteel

E11958

Clip · for types MKT (T-slot cylinder sensors) · Piston diameter 20 mm · Housing materials: POM / fixture: aluminium / screw: stainlesssteel

E11959

Clip · for types MKT (T-slot cylinder sensors) · Piston diameter 25 mm · Housing materials: POM / fixture: aluminium / screw: stainlesssteel

E11960

Clip · for types MKT (T-slot cylinder sensors) · Piston diameter 12 mm · Housing materials: POM / fixture: aluminium / screw: stainlesssteel

E11961

Clip · for types MKT (T-slot cylinder sensors) · Piston diameter 16 mm · Housing materials: POM / fixture: aluminium / screw: stainlesssteel

E11958

Clip · for types MKT (T-slot cylinder sensors) · Piston diameter 20 mm · Housing materials: POM / fixture: aluminium / screw: stainlesssteel

E11959

Cylinder sensors

54www.ifm.com

Wiring diagrams

1

L+

L

1

4

3

2

BN

BK

BU

L+

L

3

L

BN

BU

L+

4

L+

L

1

4

5

N

L1BN

BU

L+

L

6

N

L11

4

L+

L

7

L

BN

BK

BU

L+

8

L+

L

1

4

3

Scale drawings - CAD download: www.ifm.com

1

L

25

5

LED

2

1

M8x

1

37 6,5

5,1

1: Fastening clamp, 2: sensing face

2

M8x

1

L

6,5

5,1

25

5

LED

2

141,5

1: Fastening clamp, 2: sensing face

3

L

M12

x1

25

5

LED

2

1556,5

5,1

1: Fastening clamp, 2: sensing face

4

6,5

5,1

25

5

LED

2

1

1: Fastening clamp, 2: sensing face

5

6,5

5,130,5

5

5,71

1: Fastening clamp

6

30,5

5

L

M12

x1

551

5,7 6,5

5,1

1: Fastening clamp

7

L

M12

x1

25

5

LED

2

1556,5

5,1

1: Fastening clamp, 2: sensing face

8

6,5

5,1

25

5

LED1

2

1: Fastening clamp, 2: sensing face

Cylinder sensors

55www.ifm.com

Scale drawings - CAD download: www.ifm.com

9

L

6,5

5,1

25

5

1

M8x

1

37

2

LED

1: Fastening clamp, 2: sensing face

10

L

M12

x1

255

LED155

2

6,5

5,1

1: Fastening clamp, 2: sensing face

11

6,5

5,1

25

5

1

2

LED55

L

M12

x1

1: Fastening clamp, 2: sensing face

12

17,5

7,7

2,84,8

1

4,2LED

2

1: Fastening clamp, 2: sensing face

13

M8x

1

L

37

17,5

7,7

LED

2,84,8

1 2

4,2

1: Fastening clamp, 2: sensing face

14

L

M8x

1

41,5

17,5

7,7

LED

2,84,8

1 2

4,2

1: Fastening clamp, 2: sensing face

Cylinder sensors

56www.ifm.com

Cylinder sensors

57

58

Safety technology

Selection chart Page

Fail-safe inductive sensors, 2 x OSSD, to IEC62061 SILcl 2 and ISO13849-1 PL d 61

Safety relays for fail-safe sensors 61

Accessories 61

Wiring diagrams 61

Scale drawings - CAD download: www.ifm.com 62

59www.ifm.comwww.ifm.com

Certified to IEC 61508,SIL 2 / SIL 3 and ISO 13849-1 PL d / e.

Safety monitoring of persons and machines.

No coded target required for electronic fail-safe sensors.

Connection of the sensors to safety PLCs, bus systems and switching devices possible.

Series connection of sensors and contacts.

Safety technology

Safety technology in automation has a share of the responsibility for safe human-machine interaction. Fail-safe sensors with safety functions are an important part ofa safety system for persons and machines. For the first time, the operating principleand thus the advantages of inductive sensors can also be used for safety applications.Direct detection of metal solves new applications. Up to now magnetic or mechani-cal counterparts had to be considered in the design. The wear-free non-contactsensing principle and a high protection rating ensure high plant uptime.

Connection and evaluation

No special demands such as shielding, twisted cables or laying separately, are madeon the socket. The sensor is directly connected to existing PLCs or logic modulesusing common existing unshielded 4-pole cables.

The input and output signals of the sensors correspond to DIN EN 61131-2. They aretherefore fully compatible with the inputs and outputs of a PLC. Connection to ifmsafety relays, AS-i Safety at Work, PROFIsafe, Interbus Safety bus systems or safe PLCsand logic modules is equally simple. For the unit family with dynamic pulse detectionthe corresponding software modules are required.

The fail-safe sensors with 2 x PNP output can be connected to approved two-channelsafety relays without cross-monitoring that are suitable for plus-switching non-contact guards. The safety relays from ifm electronic enable functionalities such astwo-hand controls to EN 574 or connection of e-stop devices to DIN EN 574-5-1without extra cost.

Operating principle of intelligent electronic fail-safe sensors

A magnet or coded target is no longer necessary for the function of the fail-safe sen-sor. The fail-safe inductive sensor detects metals such as stainless steel or mild steel.The fail-safe sensor operates with an enable zone which is monitored for targetposition and dwell time.

Limitation of the axisareas of a robot moni-tored by the GG505S.

Connection of thesensors to safety plcs,

bus systems andrelays possible.

Safety technology

60www.ifm.com

Fail-safe inductive sensors, 2 x OSSD, to IEC62061 SILcl 2 and ISO13849-1 PL d

Type Length

[mm]

Enablezone[mm]

Housingmaterial

UbDC[V]

Protection Response timeon removal /

approach [ms]

Draw-ingno.

Orderno.

M12 connector · Wiring diagram no. 1

70 0.5...4 nf high-grade st. steel / PBT 19.2...30 IP 65 / IP 67 < 20 / < 200 1 GF711S

70 1...8 nf high-grade st. steel / PBT 19.2...30 IP 65 / IP 67 < 20 / < 200 2 GG711S

70 1...15 nf high-grade st. steel / PBT 19.2...30 IP 65 / IP 67 < 20 / < 200 3 GI711S

f = flush / nf = non flush

Safety relays for fail-safe sensors

Type Ub

[V]

Sensorinput /output

Safety-relatedoutput

Signalcontacts

(NC)

Feedbackcontacts

Responsetime[ms]

Offdelay[ms]

Draw-ingno.

Orderno.

24 DC (19.2...30DC)

1/2 2 1 1 < 180 – 4 G1501S

24 DC (19.2...30DC)

1/2 5 1 1 < 160 0...10 5 G1502S

24 DC (19.2...30DC)

1/2 2 1 1 < 100 – 6 G1503S

Accessories

Type Description Orderno.

Combicon connector · with screw terminals 4-pole · Housing materials: PA / current carrying parts: copper alloy tin-plated · Packquantity: 5

E11929

Wiring diagrams

1

(BK)

3

1

4

2

L+

L

(BN)

A2

A1

(BU)

(WH)+24 V

IN1

GND

IN2

1

Safety technology

61www.ifm.com

Scale drawings - CAD download: www.ifm.com

1

45

M12

x1

174

5

M12

x159

70

LED

2

35

M12

x1

LED 2 x 180°

70,5

M18

x1

57

424

10

3

LED 4 x 90°

M30

x1,5

5

45

70

36

M12

x1

15

57

4

35,5

25

100

LED

105

1: Combicon connector with screw terminals

5

105

35,5

114

LED

50

6

25 105

35,5

100

LED

1: screw terminal (supplied)

Safety technology

62www.ifm.com

Safety technology

63

64

Valve sensors

Selection chart Page

Sensors for industrial applications 67

Accessories 67

Scale drawings - CAD download: www.ifm.com 67

Wiring diagrams 67

65www.ifm.comwww.ifm.com

Dual inductive feedback sensors forvalves and actuators.

Straightforward fit to standard actuators.

Compact, weatherproof andlow maintenance.

Optional back wiring option for localsolenoid control.

Versions for network, hazardous areaand conventional wiring.

Valve sensors

In industrial processes where liquids, air or gases are used valves are needed fordosing and control. There is a wide variety of valve types; butterfly or ball valvesbeing the most common quarter-turn types.

These valves are seldom operated manually. Pneumatic valve actuators are normallyused for mechanical positioning. The valve position must be monitored electroni-cally.

Mechanical switches are still often used for position feedback on the actuator shaft.For other solutions several proximity sensors are used together with a switch targetfor position detection. Disadvantage: Mounting is mechanically complex. Duringswitch mounting the signal wires can be reversed when they are connected in thetop-mounted junction box. Where there are temperature fluctuations condensinghumidity leads to corrosion and thus malfunction.

Operating principle

An innovative design eliminates the disadvantages of these conventional solutions. In1992 ifm electronic developed a standard which is now used by many leading actua-tor manufacturers. A round switch target, known as a “puck”, with two metalscrews offset by 90° is mounted on the actuator shaft. The screws are located at adifferent height. A compact dual proximity switch (type IND) with two integral sen-sors detects the upper or lower metal screw depending on the valve position andthus the two switch positions.

Due to the simple construction the system operates safely with no wear at all. It isvirtually resistant to external influence and meets the protection rating IP 67. Undercertain conditions the unit can even be self-cleaning. The sensors are also resistant tomechanical stress such as vibration and shock.

Special design AS-i (T5)

An extended design is the series T5. In addition to the inductive dual sensor, the unitprovides an integrated connection for the solenoid valve. The connection to thecontrol unit is made via a two-wire AS-i cable. The asset: Up to 30 other units can beconnected to this line and separately controlled via the AS-i master.

Feedback: Monitoringof pneumatic and

manual valves mustbe possible.

Valve sensors

66www.ifm.com

Sensors for industrial applications

Type Dimensions

[mm]

Sensingrange[mm]

Material Ub

[V]

Protection fAC / DC

[Hz]

IloadAC / DC

[mA]

Draw-ingno.

Orderno.

Terminals · Output function · DC PNP · Wiring diagram no. 1

33 x 60 x 92 4 nf PA (polyamide) 10...30 IP67 500 100 1 IN5409

f = flush / nf = non flush

Accessories

Type Description Orderno.

Cable gland · M20 x 1.5 · Housing materials: PA 6.6 E12208

Protective cap · M20 x 1.5 · Housing materials: PA 6.6 E12209

Wiring diagrams

1

L

L+2

4

1

34:2:

A2A1

6

7

8

5 IN +

IN -

OUT +

OUT -

1: solenoid valve

Scale drawings - CAD download: www.ifm.com

1

33

92

6,3

18,8

60

7,5

5,5

3060M

20x1

,5

1: sensor 1, 2: sensor 2, 3: LED OUT 1, 4: LED OUT 2

Valve sensors

67www.ifm.com

68

Photoelectric sensorsinfrared / redlight

Selection chart Page

Cylindrical housing OG (M18) BasicLine DC 71

Cylindrical housing OG (M18) PerformanceLine DC 71 - 72

Cylindrical housing OG (M18) BasicLine with lateral sensing face 72

Cylindrical housing OG (M18) WetLine for hygienic and wet areas 72

OG housing with rectangular housing 73

Cylindrical housing OG (M18) BasicLine AC/DC 73

Rectangular housing OH for industrial applications 74

Rectangular housing OJ PerformanceLine, lateral sensing face 74 - 75

Rectangular housing OL for industrial applications 75

Rectangular housing O7 BasicLine 75 - 76

Rectangular housing O5 BasicLine 76

Rectangular housing O5 PerformanceLine 76

Rectangular housing O4 BasicLine 77

Rectangular housing O4 PerformanceLine 77

Accessories 77 - 79

Wiring diagrams 79

Scale drawings - CAD download: www.ifm.com 80

69www.ifm.comwww.ifm.com

Photocells for general purposes andfor harsh environments.

Visible red and infrared light sources.

Long ranges and accuratebackground suppression.

Choice of standard industrial andhigh performance units.

Accessories for simple fitting andextra mechanical protection.

Photoelectric sensors: infrared / redlight

Automation technology can no longer be imagined without photoelectric sensors as“artificial eyes”. They are used where safe and non-contact detection of the exactposition of objects is required. The material of the objects to be detected is of noimportance. Compared to proximity sensors photoelectric sensors have a muchhigher sensing zone.

Through-beam sensors

A through-beam sensor is distinguished by a long range. The system consists of twoseparate components: a transmitter and a receiver. The light only travels one way(from the transmitter to the receiver). Adverse effects in the applications, such asdust in the air, dirt on the lenses, steam or mist do not immediately interfere with thesystem. This is called a high insensitivity to dirt or a high excess gain.

Retro-reflective sensors

For a retro-reflective sensor the transmitter and receiver are incorporated into onehousing. By means of a reflector the transmitted light is returned to the receiver. Anobject in the beam path interrupts the beam and triggers a switching operation.Retro-reflective sensors without polarisation filter operate in the infrared area,systems with polarisation filter with visible red light. Compared to through-beamsensors, retro-reflective sensors have an average excess gain.

Diffuse reflection sensors

A diffuse reflection sensor is used for the direct detection of objects. Transmitter andreceiver are incorporated into one housing. The transmitter emits light which isreflected by the object to be detected and seen by the receiver. This system evaluatesthe reflected light of an object. Reflectors are not necessary for operation.

Fixing options

ifm electronic offers a complete component system of easy-to-use mounting sets.The solutions consist of a clamp which is fastened with only one screw, keeps thesensors safely in place and at the same time guarantees free movement in all axes.

The reflector reflectsthe light beam: For aretro-reflective sensortransmitter and re-ceiver are integratedinto one housing.

Artificial eyes: Photo-electric sensors are

used to detect posi-tions in automation

technology.

Photoelectric sensorsinfrared / redlight

70www.ifm.com

Cylindrical housing OG (M18) BasicLine DC

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OGE M18 x 1 · M12 connector · plastics · DC

Receiver 8 m – D PNP 10...30 1 1 OGE100

Through-beam sensor · Type OGS M18 x 1 · M12 connector · metal · DC

Transmitter 8 m 600 – 10...30 2 1 OGS100

Through-beam sensor · Type OGE M18 x 1 · M12 connector · high-grade stainless steel · DC

Receiver 20 m – D PNP 10...36 1 2 OGE200

Through-beam sensor · Type OGS M18 x 1 · M12 connector · high-grade stainless steel · DC

Transmitter 20 m 800 – 10...36 2 2 OGS200

Retro-reflective sensor · Type OGP M18 x 1 · M12 connector · plastics · DC

Polarisation filter 0.05...2.5 m 200 D PNP 10...30 1 1 OGP100

Retro-reflective sensor · Type OGP M18 x 1 · M12 connector · high-grade stainless steel · DC

Polarisation filter 0.03...4 m 160 D PNP 10...36 1 2 OGP200

Polarisation filter 0.03...4 m 160 H PNP 10...36 3 2 OGP201

Diffuse reflection sensor · Type OGT M18 x 1 · M12 connector · plastics · DC

Diffuse reflection sensor 10...400 mm 25 H PNP 10...30 1 3 OGT100

Diffuse reflection sensor · Type OGH M18 x 1 · M12 connector · high-grade stainless steel · DC

Background suppression 15...250 mm 15 H PNP 10...36 1 4 OGH200

Cylindrical housing OG (M18) PerformanceLine DC

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OGS M18 x 1 · M12 connector · high-grade stainless steel · DC

Transmitter 25 m 1000 – 10...36 2 5 OGS500

Through-beam sensor · Type OGE M18 x 1 · M12 connector · high-grade stainless steel · DC

Receiver 25 m – H/D PNP 10...36 1 6 OGE500

Photoelectric sensorsinfrared / redlight

71www.ifm.com

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Retro-reflective sensor · Type OGP M18 x 1 · M12 connector · high-grade stainless steel · DC

Polarisation filter 0.03...5 m 200 H/D PNP 10...36 1 6 OGP500

Diffuse reflection sensor · Type OGH M18 x 1 · M12 connector · high-grade stainless steel · DC

Background suppression 15...300 mm 25 H/D PNP 10...36 1 6 OGH500

Cylindrical housing OG (M18) BasicLine with lateral sensing face

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OGS · M12 connector · high-grade stainless steel · DC

Transmitter 9 m < 3000 – 10...30 2 7 OG5129

Through-beam sensor · Type OGE · M12 connector · high-grade stainless steel · DC

Receiver 9 m – H PNP 10...30 4 7 OG5127

Receiver 9 m – D PNP 10...30 5 7 OG5128

Retro-reflective sensor · Type OGP · M12 connector · high-grade stainless steel · DC

Polarisation filter 3 m < 96 H PNP 10...30 4 7 OG5125

Polarisation filter 3 m < 96 D PNP 10...30 5 7 OG5126

Diffuse reflection sensor · Type OGH · M12 connector · high-grade stainless steel · DC

Background suppression 100 mm < 16 H PNP 10...30 4 8 OG5123

Background suppression 200 mm < 28 H PNP 10...30 4 8 OG5124

Cylindrical housing OG (M18) WetLine for hygienic and wet areas

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Retro-reflective sensor · Type OGP M18 x 1 · M12 connector · high-grade stainless steel · DC

Polarisation filter 0.03...4 m 160 D PNP 10...36 1 2 OGP300

Diffuse reflection sensor · Type OGH M18 x 1 · M12 connector · high-grade stainless steel · DC

Background suppression 100 mm 8 H PNP 10...36 1 9 OGH300

Photoelectric sensorsinfrared / redlight

72www.ifm.com

OG housing with rectangular housing

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OGS-Cube · M12 connector · high-grade stainless steel · DC

Transmitter 20 m 800 – 10...30 2 10 OGS280

Through-beam sensor · Type OGE-Cube · M12 connector · high-grade stainless steel · DC

Receiver 20 m – D PNP 10...30 6 10 OGE280

Receiver 20 m – H PNP 10...30 3 10 OGE281

Retro-reflective sensor · Type OGP-Cube · M12 connector · metal · DC

Polarisation filter 0.1...4 m 160 D PNP 10...30 6 10 OGP280

Polarisation filter 0.1...4 m 160 H PNP 10...30 3 10 OGP281

Polarisation filter 0.1...4 m 160 D NPN 10...30 7 10 OGP282

Diffuse reflection sensor · Type OGH-Cube · M12 connector · metal · DC

Background suppression 100 mm 7 H PNP 10...30 3 10 OGH280

Background suppression 15...200 mm 13 H/D PNP 10...30 1 11 OGH580

Background suppression 15...200 mm 13 H/D NPN 10...30 8 11 OGH581

Cylindrical housing OG (M18) BasicLine AC/DC

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OGS M18 x 1 · 1/2“ connector · plastics · AC/DC

Transmitter 15 m 2000 – 20...250 9 12 OG0030

Through-beam sensor · Type OGE M18 x 1 · 1/2“ connector · plastics · AC/DC

Receiver 15 m – D AC/DC 20...250 10 12 OG0039*

Retro-reflective sensor · Type OGP M18 x 1 · 1/2“ connector · plastics · AC/DC

Polarisation filter 3 m 262 D AC/DC 20...250 10 12 OG0033*

Diffuse reflection sensor · Type OGT M18 x 1 · 1/2“ connector · plastics · AC/DC

Diffuse reflection sensor 1...600 mm < 169 H AC/DC 20...250 10 12 OG0035*

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 2 A (fast acting). Recommendation: check the unit for reliable function after a shortcircuit.

Photoelectric sensorsinfrared / redlight

73www.ifm.com

Rectangular housing OH for industrial applications

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OHS · Cable with connector 0.2 m · plastics · DC

Transmitter 1.2 m 10 – 10...30 2 13 OH5012

Through-beam sensor · Type OHE · Cable with connector 0.2 m · plastics · DC

Receiver 1.2 m – D PNP 10...30 6 13 OH5003

Retro-reflective sensor · Type OHP · Cable with connector 0.2 m · plastics · DC

Polarisation filter 0.8 m 10 D PNP 10...30 6 14 OH5011

Diffuse reflection sensor · Type OHN · Cable with connector 0.2 m · plastics · DC

Diffuse reflection sensor 2...50 mm 3.5 H PNP 10...30 3 15 OH5005

Diffuse reflection sensor · Type OHH · Cable with connector 0.2 m · plastics · DC

Background suppression 1...30 mm 4.5 H PNP 10...30 3 15 OH5007

Rectangular housing OJ PerformanceLine, lateral sensing face

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OJE · M8 connector · plastics · DC

Receiver 10 m – H/D NPN 10...30 11 16 OJ5032

Retro-reflective sensor · Type OJP · M8 connector · plastics · DC

Polarisation filter 0...2 m 64 H/D NPN 10...30 11 16 OJ5027

Diffuse reflection sensor · Type OJB · M8 connector · plastics · DC

Diffuse reflection sensor 1...600 mm 60 H/D NPN 10...30 11 17 OJ5023

Diffuse reflection sensor 1...1000 mm 150 H/D PNP 10...30 12 17 OJ5071

Through-beam sensor · Type OJS · M8 connector · plastics · DC

Transmitter 10 m 1000 – 10...30 2 18 OJ5130

Through-beam sensor · Type OJE · M8 connector · plastics · DC

Receiver 10 m – H/D PNP 10...30 12 18 OJ5131

Photoelectric sensorsinfrared / redlight

74www.ifm.com

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Retro-reflective sensor · Type OJP · M8 connector · plastics · DC

Polarisation filter 0...2 m 64 H/D PNP 10...30 12 18 OJ5126

Diffuse reflection sensor · Type OJB · M8 connector · plastics · DC

Diffuse reflection sensor 1...600 mm 60 H/D PNP 10...30 12 19 OJ5122

Diffuse reflection sensor · Type OJH · M8 connector · plastics · DC

Background suppression 15...400 mm < 18 H/D PNP 10...30 12 20 OJ5148

Rectangular housing OL for industrial applications

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OLS · Terminals · plastics · AC/DC

Transmitter 25 m < 2500 – 20...250 13 21 OL0006

Through-beam sensor · Type OLE · Terminals · plastics · AC/DC

Receiver 25 m – H/D relay 20...250 14 21 OL0007

Retro-reflective sensor · Type OLP · Terminals · plastics · AC/DC

Polarisation filter 0.3...5 m 250 H/D relay 20...250 14 22 OL0004*

Diffuse reflection sensor · Type OLT · Terminals · plastics · AC/DC

Diffuse reflection sensor 1...1000 mm < 300 H/D relay 20...250 14 21 OL0005*

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 5 A (fast acting). Recommendation: check the unit for reliable function after a shortcircuit.

Rectangular housing O7 BasicLine

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type O7S · Cable with connector 0.2 m · plastics · DC

Through-beam sensor 0...1.5 m 90 – 10...30 2 23 O7S200

Photoelectric sensorsinfrared / redlight

75www.ifm.com

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type O7E · Cable with connector 0.2 m · plastics · DC

Through-beam sensor 0...1.5 m – D PNP 10...30 6 24 O7E200

Retro-reflective sensor · Type O7P · Cable with connector 0.2 m · plastics · DC

Polarisation filter 0.03...1 m 55 D PNP 10...30 6 25 O7P200

Diffuse reflection sensor · Type O7H · Cable with connector 0.2 m · plastics · DC

Background suppression 1...30 mm 2.5 H PNP 10...30 3 26 O7H200

Background suppression 0...50 mm 2.5 H PNP 10...30 3 26 O7H202

Background suppression 0...100 mm 7 H PNP 10...30 3 26 O7H204

Rectangular housing O5 BasicLine

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type O5S · M12 connector · plastics · DC

Transmitter 20 m 500 – 10...36 2 27 O5S200

Through-beam sensor · Type O5E · M12 connector · plastics · DC

Receiver 20 m – D PNP 10...36 6 27 O5E200

Retro-reflective sensor · Type O5P · M12 connector · plastics · DC

Polarisation filter 0.1...7 m 175 D PNP 10...36 6 28 O5P200

Diffuse reflection sensor · Type O5H · M12 connector · plastics · DC

Background suppression 50...1400 mm 50 H PNP 10...36 3 29 O5H200

Rectangular housing O5 PerformanceLine

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Diffuse reflection sensor · Type O5H · M12 connector · plastics · DC

Background suppression 50...1800 mm 50 H/D PNP 10...36 1 30 O5H500

Photoelectric sensorsinfrared / redlight

76www.ifm.com

Rectangular housing O4 BasicLine

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Retro-reflective sensor · Type O4P · M12 connector · plastics · DC

Polarisation filter 0.3...18 m 500 D PNP 10...36 6 31 O4P200

Rectangular housing O4 PerformanceLine

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type O4S · M12 connector · plastics · DC

Transmitter 80 m 2400 – 10...36 2 32 O4S500

Through-beam sensor · Type O4E · M12 connector · plastics · DC

Receiver 80 m – H/D PNP 10...36 1 33 O4E500

Retro-reflective sensor · Type O4P · M12 connector · plastics · DC

Polarisation filter 0.3...22 m 660 H/D PNP 10...36 1 34 O4P500

Diffuse reflection sensor · Type O4H · M12 connector · plastics · DC

Background suppression 100...2600 mm 50 H/D PNP 10...36 1 35 O4H500

Accessories

Type Description Orderno.

Prismatic reflector · Ø 25 mm · round · fixing by screw · for type OA, OC, OE, OF, OG, OI, OM, OR, OS, OT, OU · Housing materials:plastics

E20953

Prismatic reflector · Ø 35 mm · round · fixing by screw · for type OA, OC, OE, OF, OG, OI, OM, OR, OS, OT, OU · Housing materials:plastics

E20954

Prismatic reflector · Ø 42 mm · round · for type O5P, OA, OC, OE, OF, OG, OH, OI, OJ, OL, OM, OR, OS, OT, OU · Housing materials:plastics

E20004

Prismatic reflector · Ø 50 mm · round · fixing by screw · for type OA, OC, OE OF, OG, OH, OI, OJ, OM, OR, OS, OS, OT, OU ·Housing materials: plastics

E20956

Prismatic reflector · Ø 80 mm · round · for type O4P, O5P, OG, OJ, OA, OC, OE OF, OH, OI, OM, OR, OS, OT, OU · Housingmaterials: plastics

E20005

Photoelectric sensorsinfrared / redlight

77www.ifm.com

Type Description Orderno.

Mounting set · for reflector · Ø 25 mm · Clamp mounting · free-standing M8 · Housing materials: fixture: stainless steel 316Ti /1.4571 / clamp: stainless steel

E20903

Mounting set · for reflector · Ø 35 mm · Clamp mounting · free-standing M8 · Housing materials: fixture: stainless steel 316Ti /1.4571 / clamp: stainless steel

E20907

Mounting set · for reflector · Ø 50 mm · Clamp mounting · free-standing M10 · Housing materials: fixture: stainless steel 316Ti /1.4571 / clamp: stainless steel

E20911

Mounting set · for reflector · Ø 80 mm · Clamp mounting · free-standing M12 · Housing materials: fixture: stainless steel 316Ti /1.4571 / clamp: stainless steel

E20915

Reflective tape for retro-reflective sensors with polarisation filter · TS-02 · 50 x 1000 mm · Housing materials: plastics E21015

Mounting set · Ø 12.2 mm · Clamp mounting · rod mounting Ø 10 mm · for type OF, IF · Housing materials: fixture: stainless steel316Ti / 1.4571 / clamp: diecast zinc

E21200

Protective bracket for free-standing and rod mounting · Ø 18 mm · Clamp mounting · Housing materials: stainless steel 316L /1.4404

E21125

Protective bracket for free-standing and rod mounting · Ø 18 mm · with end stop · Mounting clamp · Clamp mounting · Housingmaterials: Mounting clamp: PC black / Angle bracket: stainless steel 316L / 1.4404

E21126

Angle bracket · for type M18 · Housing materials: stainless steel E10736

Basic clip · OJ · Housing materials: high-grade stainless steel E20965

Swivel-mount clip · for type OJ · Housing materials: diecast zinc E20974

Angle bracket · for type OJ · Housing materials: high-grade stainless steel E20984

Mounting set · OJ · for side lens · Clamp mounting · free-standing M8 · Housing materials: fixture: stainless steel 316Ti / 1.4571 /clamp: stainless steel

E20969

Mounting set · O7 · Clamp mounting · rod mounting Ø 10 mm · Housing materials: fixture: stainless steel / clamp: stainless steel /screw: stainless steel / Nut: stainless steel

E21237

Photoelectric sensorsinfrared / redlight

78www.ifm.com

Type Description Orderno.

Angle bracket · for type O5 · Housing materials: stainless steel 316Ti / 1.4571 E21087

Mounting set · Clamp mounting · with protective cover · free-standing M10 · for type O5 · Housing materials: stainless steel 316Ti /1.4571 / clamp: diecast zinc

E21084

Dovetail clamp · for type DTS, O4, O5 · Housing materials: AlMgSi0.5 E21088

Angle bracket · O4 · for type O4 · Housing materials: stainless steel 316L / 1.4404 E21120

Angle bracket · O4 · for type O4 · Housing materials: stainless steel 316L / 1.4404 E21117

Wiring diagrams

1

L+

L

1

4

3

2

1

3

L+

L

3

L+

L

1

4

3

4

L

L+4

2 n.c.

1

3

5

L+4

2 n.c.

1

3 L

6

L+

L

1

4

3

7

L+

L

1

4

3

8

L+

L

1

4

3

9

2

3

L1

N

L+

L

10

2

3

L1

N

L+

L

11

L+

2

4

1

3 L2: Teach

12

L+2

4

1

3 L2: Teach

13

L1L+

L

1

N2

14

L+

L

L1

N2

3

1

4

Photoelectric sensorsinfrared / redlight

79www.ifm.com

Scale drawings - CAD download: www.ifm.com

1

M18

x1

M12

x134

44LED

424

3127,5

2M

18x1

M12

x1

4047

6049

LED 4 x 90°4

24

3

M18

x1

M12

x1

3444

21,4

LED

424

316,5

1

1: with pot.

4

M18

x1

M12

x1

44

59

7261

LED 4 x 90°

50

1

424

1: with pot.

5

M18

x1

M12

x1

3459

7261

LED 4 x 90°4

24

6

M18

x1

M12

x1

3459

7261

LED 4 x 90°

1

424

1: Programming buttons

7

14,5

24

M18 x1

M12 x1

70,159

,3344

16

LED 4 x 90°

8,2

8

LED 4 x 90°

13,6

75

M18 x1

M12 x1

646229

419

9,7

27

24

9

M18

x1

M12

x144

59

7261

LED 4 x 90°4

24

10

18LEDs

38

M18

x1

M12 x1

11,5

35,415,9

24,1

52

243,3

11

3,3

M18

x1

M12 x1

11,5

35,415,9

24,1

52

24

LEDs

1

18

38

1: setting pushbuttons

Photoelectric sensorsinfrared / redlight

80www.ifm.com

Scale drawings - CAD download: www.ifm.com

12

766453

M18

x1

4

5,2

86

24

LED

"20U

NF

21

1

1: pushbutton

13

3,9 9,6

12,5

3,2 15

2,9

7,6

6,4

20,6

25,1

LED

14

3,9 9,6

12,5

3,2 15

2,9

7,6

6,4

20,6

25,15,

7

LED

15

3,9 9,6

12,5

3,2 15

2,9

7,6

7,2

20,6

25,15

LED

16

45

11

LED

8,2

1

24

3,2

3,1

LED

35

M8x1

8,83,1

1

9

LED

4

1

1: pushbutton

17

11

LED

7,616

,645

1

24

3,2

3,1

LED

35

M8x1

8,83,1

1

9

LED

4

1

1: pushbutton

18

1

9

LED

4

11,6

M8x1

1

36,5

11

LED

8,2

43,5

1

24LED

35

8,5

1,8 5,

3 19

3,5

5

1: pushbutton

19

9

LED

4

11,6

1

24LED

35

8,5

1,8 5,

3 19

3,5

5

1

M8x1

36,5

11

LED

43,57,

6 16,6

1

1: pushbutton

Photoelectric sensorsinfrared / redlight

81www.ifm.com

Scale drawings - CAD download: www.ifm.com

20

24LED

35

8,5

1,8 5,

3 19

3,5

5

1

9

LED

4

11,6

1

19,5

M8x1

36,5

11

LED

43,5

1

9,5

1: pushbutton

21

27LED

1031

75

LED

1

6

62

50

49

5,5

6

LED

8,6

1

1: pushbutton

22

6

62

50

49

5,5

6

8,6

LED

127

LED

1018

13 75

LED

1

1: pushbutton

23

9

15

14,1

LED 9

26 20,3

2,7

M3

24

9

15

26 20,3

14,12,7

M3

LED 9

25

9

15

7,6

6,5

LED 9

26 20,3

2,7

M3

26

9

15

6,5

7,8

LED 926 20

,32,

7

M3

27

LED

15,4

18,2

M12 x1

17

5x9

625 1

56

6,446,8

25

70,3

5

LED

6

1

1: When a M5 mounting screw is used, the max. tightening torque is2 Nm.

Photoelectric sensorsinfrared / redlight

82www.ifm.com

Scale drawings - CAD download: www.ifm.com

28

18,2

M12 x1

1736

,5

LED

15,4

5x9

625 1

56

6,446,8

25

70,3

5

LED

6

1

1: When a M5 mounting screw is used, the max. tightening torque is2 Nm.

29

1

38

10

1

LED

24,3

15,4

18,2

M12 x1

19,5

37

5x9

625 2

56

6,446,8

25

70,3

5

1

LED

6

2

1: with pot., 2: When a M5 mounting screw is used, the max. tighte-ning torque is 2 Nm.

30

18,2

M12 x1

19,5

37

1

LED

30,5

24,3

15,4

5x9

625 2

56

6,446,8

25

70,3

5

1

LED

6

2

1: Programming buttons, 2: When a M5 mounting screw is used, themax. tightening torque is 2 Nm.

31

7,963,8

LED

40

5

8,5

74,4

86,2

1

8,5

40

5x10

1

M12 x1

27

21,1

50,9

LED

29,5

1: When a M5 mounting screw is used, the max. tightening torque is2 Nm.

32

7,963,8

LED

40

5

8,5

74,4

86,2

1

8,5

40

5x10

1

M12 x1

27

21,1

LED

29,5

1: When a M5 mounting screw is used, the max. tightening torque is2 Nm.

Photoelectric sensorsinfrared / redlight

83www.ifm.com

Scale drawings - CAD download: www.ifm.com

33

7,963,8

LED40

5

8,5

74,4

86,2

1

8,5

40

5x10

1

29,5 44

,538

,3

2

LED

M12 x1

27

21,2

1: When a M5 mounting screw is used, the max. tightening torque is2 Nm., 2: Programming buttons

34

7,963,8

LED

40

5

8,5

74,4

86,2

1

8,5

40

5x10

1

29,5 44

,538

,3

2

LED

M12 x1

27

21,2

23,5

1: When a M5 mounting screw is used, the max. tightening torque is2 Nm., 2: Programming buttons

35

7,963,8

LED

40

5

8,5

74,4

86,2

1

8,5

40

5x10

1

29,5 44

,538

,3

2

LED

M12 x1

2725

,319

,7

1: When a M5 mounting screw is used, the max. tightening torque is2 Nm., 2: Programming buttons

Photoelectric sensorsinfrared / redlight

84www.ifm.com

Photoelectric sensorsinfrared / redlight

85

86

Photoelectric sensorslaser

Selection chart Page

Cylindrical housing OG (M18) Laser PerformanceLine 89

Rectangular housing OJ Laser PerformanceLine, lateral sensing face 89

Rectangular housing O1 Laser PerformanceLine with background suppression 89

Accessories 89 - 90

Scale drawings - CAD download: www.ifm.com 90

Wiring diagrams 90

87www.ifm.comwww.ifm.com

Safe class 2 laser with visible lightfor ease of alignment.

Detect objects smaller than 1 mm across.

Long range versions for measurementup to 60 m.

Accurate and repeatable switchpoint setting.

Fine ajustment mounting bracketsfor easy installation.

Photoelectric sensors: laser

Laser systems are used where detection of small objects or precise positioning isrequired. They are available as through-beam sensors, retro-reflective sensors ordiffuse reflection sensors.

Laser light consists of light waves of identical length which have a defined phase rela-tion (coherence). This results in an important feature of laser systems, that is thealmost parallel light beam. Result: Due to the small angle of divergence long rangesof up to 60 metres can be achieved. The laser spot which is also clearly visible atdaylight simplifies the alignment of the system. Apart from the advantages somepoints have to be taken into account for the selection of the suitable optical system:compared to standard sensors the laser sensors have a reduced temperature range(-10...50 °C). In view of the small light spot and the often high ranges the system ismore sensitive to vibrations than standard sensors.

Mounting aids

The ifm laser sensors offer a useful function for easier alignment: The laser power isincreased during adjustment: This leads to a particularly bright laser spot which en-ables safe alignment from a distance even at daylight.

How dangerous are laser sensors?

Due to the small angle of divergence laser beams are focussed on a small area. Theenergy and power density on this area is extremely high. ifm laser sensors complywith the European standard EN 60825 or the international standard IEC 60825.These standards describe the operation of laser systems.

Coherent: Lasersensors emit light ofa defined wave lengthand the same phaseposition.

Photoelectric sensorslaser

88www.ifm.com

Cylindrical housing OG (M18) Laser PerformanceLine

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Through-beam sensor · Type OGSL M18 x 1 · M12 connector · high-grade stainless steel · DC

Transmitter 60 m 150 – 10...36 1 1 OGS700

Through-beam sensor · Type OGEL M18 x 1 · M12 connector · high-grade stainless steel · DC

Receiver 60 m – H/D PNP 10...36 2 2 OGE700

Retro-reflective sensor · Type OGPL M18 x 1 · M12 connector · high-grade stainless steel · DC

Polarisation filter 0.2...15 m 40 H/D PNP 10...36 2 2 OGP700

Diffuse reflection sensor · Type OGHL M18 x 1 · M12 connector · high-grade stainless steel · DC

Background suppression 20...200 mm 1.2 H/D PNP 10...36 2 2 OGH700

Rectangular housing OJ Laser PerformanceLine, lateral sensing face

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Diffuse reflection sensor · Type OJHL · M8 connector · plastics · DC

Background suppression 7...150 mm 0.8 H/D PNP 10...30 3 3 OJ5158

Background suppression 15...200 mm 2x1 H/D PNP 10...30 3 4 OJ5154

Rectangular housing O1 Laser PerformanceLine with background suppression

Type Operating principle Measuringrange

Light spotdiameter

[mm]

Ub

[V]

Currentconsumption

[mA]

Sampling rate /switching frequency

[Hz]

Draw-ingno.

Orderno.

Optical distance sensor · Type O1DL · M12 connector · metal · DC

Background suppression 0.2...10 m 6 10...30 150 5 5 O1D101

Accessories

Type Description Orderno.

Prismatic reflector · Ø 19 mm · round · fixing by screw · M3 · for laser units · for type OGPL, OJPL, OLPL · Housing materials: screw:stainless steel 316 / 1.4401 / spring washer: stainless steel 316 / 1.4401 / Nut: stainless steel 316 / 1.4401 / front plate: PMMA /base: ABS

E20993

Prismatic reflector · 30 x 20 mm · angular · for laser units · for type OGPL, OJPL, OLPL · Housing materials: front plate: PMMA / base:ABS

E20994

Photoelectric sensorslaser

89www.ifm.com

Type Description Orderno.

Prismatic reflector · 50 x 50 mm · angular · for laser sensors and glass / film detection sensors · Housing materials: plastics E20722

Swivel-mount clip · for type OJ · Housing materials: diecast zinc E20974

Mounting set · Clamp mounting · rod mounting Ø 12 mm · for type O1D, O2D · Housing materials: fixture: stainless steel / clamp:stainless steel / screws: stainless steel / Nut: high-grade stainless steel

E2D101

Wiring diagrams

1

1

3

L+

L

2

L+

L

1

4

3

3

L+2

4

1

3 L2: Teach

Scale drawings - CAD download: www.ifm.com

1

M18

x1

M12

x1

3459

7261

LED 4 x 90°4

24

2

M18

x1

M12

x1

3459

7261

LED 4 x 90°

1

424

1: Programming buttons

3

24LED

35

8,5

1,8 5,

3 19

3,5

5

1

9

LED

4

11,6

1

M8x1

36,5

11

LED

43,5

1

9,5

15,5

1: pushbutton

Photoelectric sensorslaser

90www.ifm.com

Scale drawings - CAD download: www.ifm.com

4

24LED

35

8,5

1,8 5,

3 19

3,5

5

1

9

LED

4

11,6

1

19,5

M8x1

36,5

11

LED

43,5

1

9,5

1: pushbutton

5

52

1 2

30

45

2520

4,5

6

4559

42

M12x1

30

1: 4-digit alphanumeric display, 2: Programming buttons

Photoelectric sensorslaser

91www.ifm.com

92

Photoelectric sensorsfibre optics

Selection chart Page

OOF amplifiers for acrylic fibre optics 95

OBF amplifiers for acrylic fibre optics 95

Acrylic fibre optics for OBF / OOF housings, through-beam system 95

Acrylic fibre optics for OBF / OOF housings, diffuse reflection system 95

Acrylic fibre optics for OBF / OOF housings, through-beam system, can be cut to length 96

Acrylic fibre optics for OBF / OOF housings, diffuse reflection system, can be cut to length 96

Acrylic fibres on a reel for OBF housing 96

Accessories 96

Wiring diagrams 96 - 97

Scale drawings - CAD download: www.ifm.com 97 - 98

93www.ifm.comwww.ifm.com

Acrylic and glass fibre optic sensingheads and amplifiers.

Can be used in areas where spaceand access is restricted.

Fibres for high temperatures and usewith aggressive chemicals.

Multi-channel amplifiers with displayand logic functions.

Simplified wiring and reducedspace requirement.

Photoelectric sensors: fibre optics

Fully automatic manufacturing machines become more and more compact. Fibreoptics are used where mounting space for photoelectric standard sensors is confined.Advantages of these systems: The evaluation electronics and the optoelectronic com-ponents are located separately from the sensing surface of the system. Fibre opticsensing heads can therefore be mounted in places where access is difficult. Fibreoptics are the best choice, in particular for short ranges.

Versions of fibre optic systems

Through-beam principle

Transmitting and receiving fibre optics are laid separately. The two ends (fibre opticheads) are mounted opposite each other. The light beam interruption is evaluatedaccording to the through-beam principle. The maximum range is 120 cm.

Diffuse reflection principle

Transmitting and receiving fibres are in one sheath. The sensing head incorporatesreceiving and transmitting fibre bundles. The ranges of the ifm sensors are max.70 mm.

Applications of fibre optic systems:

Confined space

The fibre optic head is directly located where sensing takes place, the mating ampli-fier where sufficient mounting space is available.

Detection of minute objects

Depending on the type of sensing head and range objects up to 0.5 mm can bedetected safely. When the movement of objects is precise, it is possible to detect finestructures, e.g. thread pitches.

High temperatures

Fibre optics with metal sheath can be used up to 290 °C, fibre optics with metalsilicone sheath up to 150 °C.

Chemical resistance

Metal silicone sheathed fibre optics are resistant to many aggressive chemicals.

Minute objects up to0.5 mm are detectedsafely.

Fibre optic systemscan also be mounted

in places where accessis difficult.

Photoelectric sensorsfibre optics

94www.ifm.com

OOF amplifiers for acrylic fibre optics

Type Numberof inputchannels

Forfibreoptics

Typeof light

Sensingrange

through beam

Sensingrangediffuse

OutputH = light-onD = dark-on

Ub

[V]

Draw-ingno.

Orderno.

Type OOF · M12 connector · plastics · DC · Wiring diagram no. 1

2 FT-11 red 3.8 m 0...300 mm H/D PNP 12...36 1 OO5000

Type OOF · M12 connector · plastics · DC · Wiring diagram no. 2

4 FT-11 red 3.8 m 0...300 mm H/D PNP 12...36 2 OO5001

Type OOF · M16 connector · plastics · DC · Wiring diagram no. 3

6 FT-11 red 3.8 m 0...300 mm H/D PNP 12...36 3 OO5002

Type OOF · M16 connector · plastics · DC · Wiring diagram no. 4

8 FT-11 red 3.8 m 0...300 mm H/D PNP 12...36 4 OO5003

OBF amplifiers for acrylic fibre optics

Type Numberof inputchannels

Forfibreoptics

Typeof light

Sensingrange

through beam

Sensingrangediffuse

OutputH = light-onD = dark-on

Ub

[V]

Draw-ingno.

Orderno.

Type OBF · M12 connector · plastics · DC · Wiring diagram no. 5

1 FT-11 red 0...2 m 0...100 mm H/D PNP/NPN 10...30 5 OBF500

Acrylic fibre optics for OBF / OOF housings, through-beam system

Type Fibre opticmaterial

RangeOB50.. / OBF5.. / OO50..

[mm]

Sensinghead

material

Ambienttemperature

[°C]

Sheathingmaterial

Draw-ingno.

Orderno.

PMMA 150 / 210 / 800 aluminium -40...70 PE (polyethylene) 6 E20615

Acrylic fibre optics for OBF / OOF housings, diffuse reflection system

Type Fibre opticmaterial

RangeOB50.. / OBF5.. / OO50..

[mm]

Sensinghead

material

Ambienttemperature

[°C]

Sheathingmaterial

Draw-ingno.

Orderno.

PMMA 20 / 25 / 60 aluminium -40...70 PE (polyethylene) 7 E20639

Photoelectric sensorsfibre optics

95www.ifm.com

Acrylic fibre optics for OBF / OOF housings, through-beam system, can be cut to length

Type Fibre opticmaterial

RangeOB50.. / OBF5.. / OO50..

[mm]

Sensinghead

material

Ambienttemperature

[°C]

Sheathingmaterial

Draw-ingno.

Orderno.

PMMA 45 / 80 / 120 aluminium -40...70 – 8 E20768

PMMA 175 / 370 / 700 aluminium -40...70 – 8 E20767

Acrylic fibre optics for OBF / OOF housings, diffuse reflection system, can be cut to length

Type Fibre opticmaterial

RangeOB50.. / OBF5.. / OO50..

[mm]

Sensinghead

material

Ambienttemperature

[°C]

Sheathingmaterial

Draw-ingno.

Orderno.

PMMA 55 / 110 / 235 aluminium -40...70 – 9 E20765

Acrylic fibres on a reel for OBF housing

Type Description Orderno.

acrylic fibres on a reel · 20 m · for type OBF · Housing materials: PE / Fibre: : PMMA E20773

acrylic fibres on a reel · 50 m · for type OBF · Housing materials: PE / Fibre: : PMMA E20774

Accessories

Type Description Orderno.

cutter for fibre optics · Housing materials: plastics E20600

Wiring diagrams

1

L+

L

1

4

2

7

3Out 2Out 1

2:4:

7: function check

Photoelectric sensorsfibre optics

96www.ifm.com

Wiring diagrams

2

4:2:5:

Out 1Out 2Out 3

6: Out 4

L+

L

1

4

6

7

3

7: function check

3

L+

L

A

E

T

O

L

E:P:S:

Out 1Out 2Out 3

G: Out 4C:T:

Out 5Out 6

O: function check

4

E:P:S:

Out 1Out 2Out 3

G: Out 4C:T:

Out 5Out 6

N:J:

Out 7Out 8

L+

L

A

E

J

O

L

O: function check

5

2

L

L+4

1

3

4

L

L+2

1

3

Scale drawings - CAD download: www.ifm.com

1

1: mounting on DIN rail

2

1: mounting on DIN rail

Photoelectric sensorsfibre optics

97www.ifm.com

Scale drawings - CAD download: www.ifm.com

3

1: mounting on DIN rail

4

1: mounting on DIN rail

5

15

36

LED

2

M12

x1

1

74

6044

3,2

1: mounting on DIN rail, 2: setting pushbuttons

6

15

M4

7

23

M416

8

3010,5

5

M5

9

40

M89

14,5

Photoelectric sensorsfibre optics

98www.ifm.com

Photoelectric sensorsfibre optics

99

100

Photoelectric sensorsspecific systems

Selection chart Page

Sensors for the detection of transparent objects 103

Sensors for distance and level measurement 103

Sensors for colour detection 103 - 104

Safety light grids 104

Accessories 104

Evaluation units light curtains / safety light grids 104

Scale drawings - CAD download: www.ifm.com 105

Wiring diagrams 105

101www.ifm.comwww.ifm.com

High-quality photoelectric sensorsfor different applications.

Excellent price / performance ratio.

Extremely compact laser distancesensor with 10 m range.

Sensor for the detection of transpa-rent objects (PET, glass, film etc.).

Extensive range of system componentsfor easy and safe mounting.

Detection of transparent objects

Counting bottles and glasses or the reliable monitoring of film for tear can be per-formed without problem using specially designed retro-reflective sensors.

ifm offers a retro-reflective sensor with a small switching hysteresis, in particular forthe detection of transparent objects. Due to the operating principle, retro-reflectivesensors have the advantage that the light beam must pass the object to be detectedtwice. Thus the light is sufficiently weakened to detect a transparent object safely.Precise adjustment is made by means of the Teach button.

Distance measurement

The continued development of the pmd technology (Photonic Mixer Device) nowenables distance measurement to within a millimetre at high ranges using a lasersensor. The efector pmd laser sensor operates to the time-of-flight principle: A lightbeam is emitted by a transmitting element and reflected to the receiver element byan object. The measured time of flight relates to the distance from the sensor to theobject.

Traditional time-of-flight sensors use a photodiode as receiver element. Additionalelectronics is used for signal acquisition and processing.

Disadvantage: This sensor design is complex, large in size and therefore often notsuitable for industrial position sensing.

In comparison, the efector pmd sensor’s receiver element is a “System-on-Chip”design: both sensor element and electronics for signal evaluation are integrated on asingle silicon chip called a Photonic Mixer Device (PMD).

The advantage: The sensor offers a high performance in a compact, industrially com-patible housing.

“efector pmd” can be used for level measurement and positioning tasks, for exam-ple to position industrial trucks in high bay storage areas and to protect autonomousindustrial transport systems against collision.

Typical application forcontrast sensors:Counting of glassbottles.

The efector pmdprovides an analoguesignal that is propor-tional to the object-to-sensor distance.

Photoelectric sensorsspecific systems

102www.ifm.com

Sensors for the detection of transparent objects

Type Operating principle Sensingrange

Spot Ø atmax.range[mm]

OutputH = light-onD = dark-on

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Retro-reflective sensor · Type OJPG · M8 connector · plastics · DC

Polarisation filter 0.2...1.5 m 64 H/D PNP 10...30 1 1 OJ5186

Retro-reflective sensor · Type O5G · M12 connector · plastics · DC

Polarisation filter 0...1.5 m 40 / 80 H/D PNP/NPN 10...36 6 2 O5G500

Sensors for distance and level measurement

Type Operating principle Measuringrange

Light spotdiameter

[mm]

Ub

[V]

Currentconsumption

[mA]

Sampling rate /switching frequency

[Hz]

Draw-ingno.

Orderno.

M12 connector · Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable oranalogue (4...20 mA / 0...10 V, scalable) · DC PNP · Wiring diagram no. 7

Optical distance sensor 0.2...10 m 6 18...30 150 1...50 3 O1D100

M12 connector · Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable oranalogue (4...20 mA / 0...10 V, scalable) · DC NPN · Wiring diagram no. 8

Optical distance sensor 0.2...10 m 6 18...30 150 1...50 3 O1D103

M12 connector · Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable oranalogue (4...20 mA / 0...10 V, scalable) · DC PNP · Wiring diagram no. 7

Optical distance sensor 0.3...6 m 6 18...30 150 1...33 3 O1D155

Optical distance sensor 0.2...10 m 6 18...30 150 1...33 3 O1D105

Optical level sensor 0.2...10 m 6 18...30 150 1...33 3 O1D300

Optical distance sensor 1...75 m 150 18...30 150 1...33 3 O1D106

Sensors for colour detection

Type Operating principle Measuringrange

Light spotdiameter

[mm]

Ub

[V]

Currentconsumption

[mA]

Sampling rate /switching frequency

[Hz]

Draw-ingno.

Orderno.

M12 connector · Output function light-on / dark-on programmable · DC PNP/NPN · Wiring diagram no. 2

Colour sensor 17 mm 2.5 x 6 10...36 50 2000 4 O5C500

M12 connector · DC PNP · Wiring diagram no. 3

Colour sensor 12.5 mm 2 x 4 12...30 80 1000 5 OD5005

Colour sensor 60 mm 13 12...30 80 1000 5 OD5007

Photoelectric sensorsspecific systems

103www.ifm.com

Type Operating principle Measuringrange

Light spotdiameter

[mm]

Ub

[V]

Currentconsumption

[mA]

Sampling rate /switching frequency

[Hz]

Draw-ingno.

Orderno.

M12 connector · DC PNP · Wiring diagram no. 4

Colour sensor 12.5 mm 2 x 4 12...30 80 300 5 OD5009

Colour sensor 60 mm 13 12...30 80 300 5 OD5011

M12 connector · DC PNP · Wiring diagram no. 3

Colour sensor 9 mm – 12...30 80 1000 6 OD5013

Safety light grids

Type Numberof beams

Protectedarea height

[mm]

Protectedarea width

[m]

Responsetime

[ms]

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Complies with the requirements: type 4 , SIL 3 , SILcl 3 , PL e · M12 connector

2 510 0...10 / 3...20 2.5 24 5 7 OY120S

3 810 0...10 / 3...20 2.5 24 5 7 OY121S

4 910 0...10 / 3...20 2.5 24 5 7 OY122S

Accessories

Type Description Orderno.

Angle bracket · for type O5 · Housing materials: stainless steel 316Ti / 1.4571 E21087

Prismatic reflector · 50 x 50 mm · angular · for laser sensors and glass / film detection sensors · Housing materials: plastics E20722

Mounting set · Clamp mounting · rod mounting Ø 12 mm · for type O1D, O2D · Housing materials: fixture: stainless steel / clamp:stainless steel / screws: stainless steel / Nut: high-grade stainless steel

E2D101

Evaluation units light curtains / safety light grids

Type Description Draw-ingno.

Orderno.

Safety relay · Muting relay · Housing for DIN rail mounting · For the connection of safety light curtains / safety light gridswith OSSD · Safety category type 4 to IEC 61496 · for industrial applications

8 G2001S

Photoelectric sensorsspecific systems

104www.ifm.com

Wiring diagrams

1

L+2

4

1

3 L2: Teach

2

L+

L

2

5

1

4

3Out

N.C.

AT

2: Input AT activation trigger

3

L+

L

2

5

1

4

3Out

2: Input AT activation trigger,5: input „External Teach“

4

Out 3

5

3

1

4

6

Out 1

Out 2

L+2

L7

1: Input AT activation trigger,5: input „External Teach“

5

5

4

3

2

6

7

1 OSSD1

OSSD2

K1/K2/Restart

SEL_A

SEL_B

8

L+

L

6

L+

L

2

5

1

4

3

n.c.

L+

L

2

5

1

4

3

n.c.

7

L+

L3

4

2

1

Out 1Out 2

4:2:

4

L

L+1

2

3Out 1Out 2

4:2:

8

L

L+

Out 2Out 1

2:4: 3

4

2

1L+

LOut 2Out 1

2:4: 3

2

4

1

Scale drawings - CAD download: www.ifm.com

1

1

9

LED

4

11,6

M8x1

1

36,5

11

LED

8,2

43,5

1

24LED

35

8,5

1,8 5,

3 19

3,5

5

1: pushbutton

2

18,2

M12 x1

19,5

37

1

LED

30,5

24,3

15,4

5x9

625 2

56

6,446,8

25

70,3

5

1

LED

6

2

1: Programming buttons, 2: When a M5 mounting screw is used, themax. tightening torque is 2 Nm.

Photoelectric sensorsspecific systems

105www.ifm.com

Scale drawings - CAD download: www.ifm.com

3

52

1 2

30

45

2520

4,5

6

4559

42

M12x1

30

1: 4-digit alphanumeric display, 2: Programming buttons

4

56

6,446,8

25

70,3

5

1

LED

6

2

1

LED

30,5

24,3

15,4

5x9

625 2

18,2

M12 x1

25,9

38

1: Programming buttons, 2: When a M5 mounting screw is used, themax. tightening torque is 2 Nm.

5

4380

M12

x1

96

28

21 30

M5

M12

x1

3928

4053

69

M5

15

1

LED

LED

2

3

4

1: lens, 2: selection switch color tolerance, 3: programming selectorswitch, 4: teach button

6

4380

M12

x1

96

28

21 30

M5

119

M12

x1

3928

4053

69

M5

LED

LED

2

3

4

14

1

1: fibre optic connection, 2: selection switch color tolerance, 3: pro-gramming selector switch, 4: teach button

7

40 2010

3

1010,528

28

5,5

40

10

2010

1,5

M5

14,5

30

28

T

M12x1

5129

,510

2L

R

T: Transmitter, R: Receiver, 1: LED 3 colours (red/green/orange), 2:LED yellow, 3: LED 2 colours (red/green)

8

114,5

99

35

Photoelectric sensorsspecific systems

106www.ifm.com

Photoelectric sensorsspecific systems

107

108

Object recognition

Selection chart Page

Sensors for object recognition with PNP output function 111

Accessories 2D 111

Sensors for 3D object recognition 111

Accessories 3D 112

Scale drawings - CAD download: www.ifm.com 112

109www.ifm.comwww.ifm.com

2D vision sensor for object recognition.

3D sensor for assessment of distance, level or volume.

3D camera for spatial detection of scenes and objects.

Easy, time-saving parameter setting.

Robust, industrially compatible housing with integrated lighting.

2D vision sensor for object recognition

In automation technology visions sensors are an integral part of assembly and manu-facturing tasks as well as quality control and thus increase efficiency. They arecameras with application-specific evaluation, i.e. reliable electronic eyes at a low costand a high degree of integration. In a robust, industrially compatible housing theycombine lighting, lens, camera chip, evaluation and process connections for the inte-gration in the higher-level controller.

The application possibilities of efector dualis range from presence, position andorientation monitoring, via sorting and counting tasks to quality control.

3D sensor for assessment of distance, level or volume

efector pmd 3d is the first industrial 3D sensor that can assess objects in three dimen-sions at a glance.

Special feature: the time-of-flight measurement and evaluation are integrated onone chip. Each pixel of this chip matrix evaluates its distance to the object. The imageof the object on the chip matrix and the respective distance values correspond to a3D image.

This technology enables the detailed assessment of the object’s or scene’s conditionsby means of volume, distance or level detection in three dimensions. Typical applica-tions are completeness checks and level monitoring in the food industry as well aspresence and dimension monitoring in conveying.

3D camera for detection in three dimensions of scenes and objects

The pmd 3d camera detects scenes and objects in their spatial dimensions at aglance. In contrast to laser scanners it does not require moving components and isthus robust and wear-free. The operating principle is the same as for the 3D sensor.

Besides the 3D distance image the camera provides a grey image of the scene. Thecombination of these images offers integrators the possibility to freely programapplication-specific tasks by means of a software development kit. This results in low-cost application solutions in the areas of packaging, storage and materials handling,airport logistics, collision avoidance, robotics, monitoring of space and persons.

Set-up in just a fewsteps: The profes-sional and easy menuguidance allowsconfiguration of theefector dualis to yourapplication in just sixoperating steps.

Object recognition

110www.ifm.com

Sensors for object recognition with PNP output function

Type Operatingprinciple

Typeof light

Max.field of

view size[mm]

Detectionrate

[Hz]

Motionspeed(max.)[m/s]

Draw-ingno.

Orderno.

Type O2D2 · · metal · DC

Object recognition sensor – 640 x 480 10 1 1 O2D220

Accessories 2D

Type Description Orderno.

Operating software · O2D E2D200

Mounting set · O2D, O2M, O2I · Clamp mounting · rod mounting Ø 12 mm · Housing materials: fixture: stainless steel / clamp:stainless steel

E2D110

mounting rod · Ø 14 / M12 · Length: 130 mm · straight · Housing materials: stainless steel 316Ti / 1.4571 E20939

mounting rod · Ø 14 / M12 · Length: 200 mm · angled · Housing materials: stainless steel 316Ti / 1.4571 E20941

Cube · M12 · aluminium profile · Housing materials: diecast zinc E20952

Plastic protective pane for the food industry · O2D / O2I · Housing materials: housing: diecast zinc black / lens: PMMA E21166

Patch cable · Cross-over patch cable · Cable length 5 m E30112

Socket · ifm electronic · angled · Free from silicone · Free from halogen · gold-plated contacts · M12 connector · 5 m · Housingmaterials: PUR

E11232

Sensors for 3D object recognition

Type Operatingprinciple

Reso-lution

[pixels]

Angle of aperture(horizontal x

vertical)[°]

Lighting Max.sampling

rate[Hz]

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

PMD 3D sensor · Type O3D · M12 connector · metal · DC

PMD 3D sensor 64 x 48 30° x 40° Infrared LED 20 24 1 2 O3D200

Object recognition

111www.ifm.com

Accessories 3D

Type Description Orderno.

Operating software for PMD 3D sensor · O3D E3D200

Mounting set · O3D · Clamp mounting · rod mounting Ø 14 mm · Housing materials: fixture: stainless steel / clamp: stainless steel E3D103

mounting rod · Ø 14 / M12 · Length: 130 mm · straight · Housing materials: stainless steel 316Ti / 1.4571 E20939

Scale drawings - CAD download: www.ifm.com

1

M12x1

2

19

M12x1

53,5

4,3

20,5

44

19,733

1

45

24,5

42

57

8060

21

9,57

3

1: display, 2: Focus setting, 3: Centre of the lens axes

2

95

60,540

4563

,8

16

75

137

120

123,

5

18M12x1

M12x1

94

21,5

1: lens, 2: Illumination unit, 3: Display / buttons / LEDs, 4: Focus set-ting

Object recognition

112www.ifm.com

Object recognition

113

114

Encoders

Selection chart Page

Incremental encoders with solid shaft 117

Incremental encoders with hollow shaft 117

Absolute multiturn encoders (Profibus) 117

Absolute singleturn - encoders (CANopen) 117

Absolute multiturn - encoders (CANopen) 118

Accessories 118

Scale drawings - CAD download: www.ifm.com 118 - 119

115www.ifm.comwww.ifm.com

Robust designs.

Industrial standard housings.

Cable entry for axial and radial use.

Designs with integrated bus interface.

Hollow shaft encoder for direct mounting on actuators.

Encoders

In many manufacturing and production processes they are indispensable as reliabletransducers to ensure precise positioning. They convert rotary movement into digitalsignals. Linear measurement is also possible in conjunction with rack and pinion ormeasuring wheels. Encoders use the wear-free photoelectric detection. A pulse discfirmly attached to the shaft ensures this detection. Encoders are basically divided intotwo types: incremental and absolute encoders.

Incremental encoders

Incremental encoders generate a precisely defined number of pulses per revolution.They are a measure of the angular or linear distance moved. The coded disc is dividedinto separate segments which are alternately transparent or opaque. An LED emits aparallel-orientated light beam which illuminates all segments of the coded disc.Photo elements receive the modulated light and convert it into two sinusoidal sig-nals. Digitalisation electronics amplify the signals and shape them into square-wavepulse trains which are generated via the line driver in the output. The phase differ-ence between signal A and B, which are phase-shifted by 90 degrees, allows evalua-tion of the direction of rotation.

Absolute encoders

Absolute encoders provide an absolute numerical value for each angular position.This code value is available immediately after power is applied. This “absolute” valuemakes a reference procedure like the one required for the incremental encoderunnecessary. Absolute encoders are used wherever angular positions have to beallocated to a certain value and where the detection of the present position is abso-lutely necessary in the case of a power failure.

Singleturn and multiturn

Singleturn encoders divide a mechanical revolution (0 to 360 degrees) into a certainnumber of measuring steps. The measuring values are repeated after one revolution.The maximum resolution is 8192.

Multiturn encoders, however, do not only detect angular positions but also distin-guish between multiple revolutions.

Linear measurementby means of a count-er: rotary movementis converted intodigital signals.

Hollow shaft encoderfor direct mounting

on the axis.

Encoders

116www.ifm.com

Incremental encoders with solid shaft

Type Resolution Ub

[V]

f

[kHz]

Iload

[mA]

Shaft

[mm]

Ambienttemperature

[°C]

Cableentry

Draw-ingno.

Orderno.

Cable 2 m · Output TTL output 20 mA

500 5 300 20 6 -30...100 radial / axially 1 RB1015

Cable 2 m · Output HTL-output 50 mA, short-circuit protected < 1 min

125 10...30 160 50 6 -30...70 radial / axially 1 RB6009

500 10...30 160 50 6 -30...70 radial / axially 1 RB6015

1000 10...30 160 50 6 -30...70 radial / axially 1 RB6029

Cable 2 m · Output TTL output 20 mA

500 5 300 20 6 -40...100 radial / axially 2 RU1016

1024 5 300 20 6 -40...100 radial / axially 2 RU1025

Incremental encoders with hollow shaft

Type Resolution Ub

[V]

f

[kHz]

Iload

[mA]

Shaft

[mm]

Ambienttemperature

[°C]

Cableentry

Draw-ingno.

Orderno.

Cable 1 m · Output HTL-output 50 mA, short-circuit protected < 1 min

500 10...30 300 50 12 H7 -40...100 radial / axially 3 RO6344

1024 10...30 300 50 12 H7 -40...100 radial / axially 3 RO6345

Absolute multiturn encoders (Profibus)

Type Resolution Ub

[V]

f

[kHz]

Iload

[mA]

Shaft

[mm]

Ambienttemperature

[°C]

Cableentry

Draw-ingno.

Orderno.

Terminals · Output Profibus data interface

25 bits 10...30 – – 10 -40...70 – 4 RM3005

Absolute singleturn - encoders (CANopen)

Type Resolution Ub

[V]

f

[kHz]

Iload

[mA]

Shaft

[mm]

Ambienttemperature

[°C]

Cableentry

Draw-ingno.

Orderno.

Terminals · Output CANopen interface

13 bits 9...36 – – 6 -40...70 – 5 RN7003

13 bits 9...36 – – 10 -40...70 – 4 RN7004

Encoders

117www.ifm.com

Absolute multiturn - encoders (CANopen)

Type Resolution Ub

[V]

f

[kHz]

Iload

[mA]

Shaft

[mm]

Ambienttemperature

[°C]

Cableentry

Draw-ingno.

Orderno.

Terminals · Output CANopen interface

25 bits 9...36 – – 6 -40...70 – 5 RM7003

25 bits 9...36 – – 10 -40...70 – 4 RM7004

Accessories

Type Description Orderno.

Angle bracket · for encoders · for type RB, RC, RU, RN, RM · Housing materials: aluminium black anodised E60033

Angle bracket · for encoders · for type RM, RMU, RN, RU · Housing materials: aluminium black anodised E60034

Flexible coupling with clamp connection [KV] · Ø 6 mm / Ø 6 mm · Housing materials: aluminium E60064

Flexible coupling with adjusting screw connection [SV] · Ø 6 mm / Ø 6 mm · Housing materials: aluminium E60063

Flexible coupling with adjusting screw connection [SV] · Ø 6 mm / Ø 10 mm · Housing materials: aluminium E60028

Scale drawings - CAD download: www.ifm.com

1

251

237,5

618 35

215

30°

4,5

1: reference mark, 2: M3 5 mm deep

2

4

3

650 58

3

10

h7

46,7±0,5

6

120°

421 2

1: reference mark, 2: M4 5 mm deep

Encoders

118www.ifm.com

Scale drawings - CAD download: www.ifm.com

3

2063 68

3,2

6

34,5

12H

724

28

47,2±0,5

58

TX 8

4

120°

48

20°

24

1

70

18

1036 58

20

f8

10

1: M4 5 mm deep

5

120°

42

20°

24

1

80

18

4

3

650 58

3

10,5

h7

1: M4 5 mm deep

Encoders

119www.ifm.com

120

Evaluation systems

Selection chart Page

Universal speed monitors 123

Speed monitor with integrated sensor 123

Multifunctional displays for digital signals / frequency input 123

Universal counters 123

Multifunctional displays for analogue standard signals 124

Accessories 124

Scale drawings - CAD download: www.ifm.com 124

Wiring diagrams 124

121www.ifm.comwww.ifm.com

Easy adjustment and parameter setting.

Clear LCD display with simplepushbutton setup.

Primary voltage 24V dc or 110 / 230V ac.

Switching relays and transistor outputs.Analogue also available.

Standstill, overspeed, direction, slipand frequency conversion.

Evaluation systems

Although PLC applications in industrial automation are becoming more and moreversatile there are still numerous processes in practice which require decentralisedmonitoring.

For this ifm electronic offers a number of pulse evaluation systems in the productgroup “ecomat 200”. The application area ranges from simple standstill monitoringor blockage protection of a conveyor belt, maximum speed monitoring in windpower stations, slip monitoring of couplings through to direction monitoring, e.g.twin pumps with non-return valves.

Different units for rail mounting and compact designs in M18 and M30 metalhousings are available. They include microprocessor-controlled units for panemounting to display analogue signals, RPM, speeds, processing times, quantities andelectronic preset counters for the detection of quantities or linear measurement aswell as electronic timer relays.

All units are distinguished by a high reliability and easy handling. Independent of thePLC they indicate operating states or signal faults. This helps to reduce downtimesand production loss.

ifm electronic offers the following evaluation systems:

Speed monitor

Standstill monitor

Slip- / synchronisation monitor

Direction monitor

Frequency-to-current converter

Threshold relay

Displays with frequency and analogue input

Counters

Switching amplifiers

Pulse evaluationsystems are used fordecentralised moni-toring of drives.

Machine cycles mustalso be monitored in

conveying.

Evaluation systems

122www.ifm.com

Universal speed monitors

Type Ub

[V]

In-puts

Inputfunction

Settingrange

[puls. / min.]

Settingrange[Hz]

Out-puts

analog

Out-puts

relays

Out-puts

transist.

Draw-ingno.

Orderno.

Type FR-1 · dual-chamber terminals 2 x 2.5 mm² (2 x AWG 14) · plastics

110...240 AC/DC / 27 DC 1 PNP / NPN / Namur 1...60000 0.1...1000 1 2 2 1 DD2003

Speed monitor with integrated sensor

Type Sensingrange[mm]

Electricaldesign

Ub

[V]

Settingrange

[puls. / min.]

Start-updelay

[s]

Terminalconnection

no.

Draw-ingno.

Orderno.

10 f AC/DC 20...250 AC/DC 5...300 12 1 2 DI0001*

10 f DC PNP 10...36 DC 3...300 15 2 2 DI5001

10 f DC PNP 10...36 DC 3...300 15 3 3 DI5009

12 nf DC PNP 10...36 DC 3...6000 0...15 4 4 DI6001

f = flush / nf = non flush

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 2 A (fast acting). Recommendation: check the unit for reliable function after a shortcircuit.

Multifunctional displays for digital signals / frequency input

Type Ub

[V]

In-puts

Inputfunction

Settingrange

[puls. / min.]

Settingrange[Hz]

Out-puts

analog

Out-puts

relays

Out-puts

transist.

Draw-ingno.

Orderno.

Type FX 360 · 10 screw terminals...1.5 mm² (DC and inputs) · plastics · AC/DC

115/230 2 PNP / NPN – – – – 2 5 DX2003

Universal counters

Type Ub

[V]

In-puts

Inputfunction

Settingrange

[puls. / min.]

Settingrange[Hz]

Out-puts

analog

Out-puts

relays

Out-puts

transist.

Draw-ingno.

Orderno.

Plug-in screw terminals · plastics

90...260 AC 1 PNP / NPN – – – 2 – 6 E89005

Evaluation systems

123www.ifm.com

Multifunctional displays for analogue standard signals

Type Ub

[V]

In-puts

Inputfunction

Settingrange

[puls. / min.]

Settingrange[Hz]

Out-puts

analog

Out-puts

relays

Out-puts

transist.

Draw-ingno.

Orderno.

terminals up to 2.5 mm² · plastics

– 1 4...20 mA – – 1 2 2 7 E89150

Accessories

Type Description Orderno.

Angle bracket · for type M18 · Housing materials: stainless steel E10736

Angle bracket · for type M30 · Housing materials: stainless steel E10737

Wiring diagrams

1

BN

BU

L+L1

LN

2

BN

BK

BU

L+

L

3

L+

L

1

4

3

4

4

L

L+1

2

3

2: pulse output (the pulsesequence corresponds to thedamping frequency), 4: swit-ching output (adjustable)

Scale drawings - CAD download: www.ifm.com

1

45

78

1 4 652

19 20 21 22 23 24

13 14 15 16 17 18

3

97A1 8A2 10 11 12

120

35,5

1

1: mounting on DIN rail

2

36

8167

58

5

M30

x1,5

9

18

2 LED

pot. 61

3

36

8266

59

5LED

M30

x1,5

M12

x1

92

pot.

4

M12

x1

77

5640

M18

x1

68

10

42421

1: 3 LED, 2: setting pushbutton

Evaluation systems

124www.ifm.com

Scale drawings - CAD download: www.ifm.com

5

96

48

129 9

6

48105

86,5 3

45

7

75

39

50 4

33

control panel cutout: 68 x 33 mm (according to DIN)

Evaluation systems

125www.ifm.com

126

Level sensors

Selection chart Page

Sensors for oils and coolants, LK12xx: approval to the German overspill standard WHG,section 19 129

Variable level sensors for water-based media (dielectric constant > 20) 129

Sensors for hydrostatic level monitoring 129 - 130

Sensors for hydrostatic level monitoring in hygienic and wet areas 130

Sensors for oils and coolants, LI20xx: approval to the German overspill standard WHG,section 19 131

Accessories for level sensors LK, LR, LT, LL, LI 131

Accessories for level sensors PA, PG, PI, PN, PS, PY 132

Scale drawings - CAD download: www.ifm.com 133

Wiring diagrams 133

127www.ifm.comwww.ifm.com

Guided wave radar, capacitive andhydrostatic level sensors.

No movings parts means highreliability and long life.

Outputs for continuous or discretelevel measurement.

Integrated LED display for localindication of the current level.

Units suitable for common industrialand process fluids.

Level sensors

In industrial applications where fluids or bulk material are used, storage tanks or silosare used for processing or storing of media. Sensors are used to detect the levels.Even critical process conditions such as emptying a hydraulic tank or the uninten-tional overspill of a tank are monitored by level sensors.

Advantages of electronic sensors

Deposits and wear and tear often lead to failures in particular if mechanical switchesare in contact with the medium. The electronic ifm sensors however can do withoutany mechanical components. This makes the sensors especially robust and reliable.

Another advantage of electronic sensors is the local indication of the level or the easysetting of the switching threshold simply by pressing a button.

Measurement technique

For continuous level measurement the level is detected continuously, converted intoan electrical signal and indicated. Depending on the type the units have freely pro-grammable switching outputs or an analogue output for further processing.

Continuous level sensors from ifm electronic use three different physical measuringprinciples:

For capacitive measurement the probe and the tank form an electrical capacitor. Thecapacity changes with the level and is converted into a level measurement by amicroprocessor.

For hydrostatic level measurement a measuring cell detects the hydrostatic pressureof the material. Here the pressure change is a measure for the level.

The efector gwr level sensor operates on the principle of guided wave radar. Electro-magnetic pulses are transmitted by the sensor head and guided along the probe. Ifthe microwave pulse hits the medium to be detected, it is reflected and the time offlight is evaluated by the sensor.

Measurement inthe medium:Probe sensors willdirectly immersed inthe medium to bemonitored.

For special applica-tions: Capacitive

probe for monitoringoils and coolants.

Level sensors

128www.ifm.com

Sensors for oils and coolants, LK12xx: approval to the German overspill standard WHG, section 19

Type Probelength[mm]

Activezone[mm]

Inactive zone[mm]

Ub

[V]

Mediumtemperature

[°C]

Iload

[mA]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector (according to EN 61076-2-101) · Output function 1 x analogue 4...20 mA / 0...10 V (OUT2); 1 x normally open / clo-sed programmable (OUT-OP) · DC PNP

264 195 53 / 15 18...30 – 200 1 1 LK3122

472 390 53 / 30 18...30 – 200 1 1 LK3123

728 585 102 / 40 18...30 – 200 1 1 LK3124

M12 connector (according to EN 61076-2-101) · Output function 2 x normally open / closed programmable · DC PNP

264 195 53 / 15 18...30 – 200 2 1 LK1022

472 390 53 / 30 18...30 – 200 2 1 LK1023

728 585 102 / 40 18...30 – 200 2 1 LK1024

M12 connector (according to EN 61076-2-101) · Output function 3 x normally open / closed programmable (OUT1...OUT3); 1 x nor-mally open / closed programmabl (OUT-OP) · DC PNP

264 195 53 / 15 18...30 – 200 3 1 LK8122

472 390 53 / 30 18...30 – 200 3 1 LK8123

728 585 102 / 40 18...30 – 200 3 1 LK8124

Variable level sensors for water-based media (dielectric constant > 20)

Type Probelength[mm]

Activezone[mm]

Inactive zone[mm]

Ub

[V]

Mediumtemperature

[°C]

Iload

[mA]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector (according to EN 61076-2-101) · Output function normally open / closed programmable; 4...20 mA or 0...10 V · DCPNP

150...1600 L - 50 40/10 18...30 0...80 200 4 2 LR3000

M12 connector (according to EN 61076-2-101) · Output function 2 x normally open / closed programmable · DC PNP

150...1600 L - 50 40/10 18...30 0...80 200 2 2 LR7000

M12 connector (according to EN 61076-2-101) · Output function 4 x normally open / closed programmable · DC PNP

150...1600 L - 50 40/10 18...30 0...80 200 5 3 LR8000

Sensors for hydrostatic level monitoring

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) · DC PNP/NPN

G¼ I Display unit -0.25...0.25 10 30 18...32 9 4 PY2068

M12 connector · Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 xanalogue (4...20 mA / 0...10 V; scaleable 1:4) · DC PNP/NPN

G¼ I Display unit -0.5...0.5 10 30 20...30 10 5 PN2069

Level sensors

129www.ifm.com

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Cable 3 m · Output function 4...20 mA analogue · DC

– – 0...0.25 2 2.4 10...30 6 6 PS3208

Cable 10 m · Output function 4...20 mA analogue · DC

– – 0...0.6 4 4.8 10...30 6 6 PS3407

Cable 12 m · Output function 4...20 mA analogue · DC

– – 0...1 5 6 10...30 6 6 PS3417

M12 connector · Output function 4...20 mA analogue · DC

G¼ I – 0...0.25 10 30 9.6...32 7 7 PA3028

Sensors for hydrostatic level monitoring in hygienic and wet areas

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) · DC PNP/NPN

Aseptoflex Display unit -1...1 10 30 18...32 9 8 PI2099

Aseptoflex Display unit -0.0124...0.25 10 30 18...32 9 8 PI2098

Aseptoflex Display unit -0.05...1 10 30 18...32 9 8 PI2097

M12 connector · Output function 4...20 (20...4) mA analogue (scaleable 1:4) · DC

Aseptoflex Display unit -1...1 10 30 20...32 11 8 PI1099

Aseptoflex Display unit -0.05...1 10 30 20...32 11 8 PI1097

M12 connector · Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed pro-grammable or 1 x analogue (4...20 / 20...4 mA, scalable) · DC PNP/NPN

Aseptoflex Vario Display unit -0.005...0.1 4 30 18...32 10 9 PI2789

Aseptoflex Vario Display unit -0.0124...0.25 10 30 18...32 10 9 PI2798

Aseptoflex Vario Display unit -1...1 10 30 18...32 10 9 PI2799

Aseptoflex Vario Display unit -0.05...1 10 30 18...32 10 9 PI2797

Aseptoflex Vario Display unit -0.124...2.5 20 50 18...32 10 9 PI2796

M12 connector · Output function 1 x normally open / closed programmable + 1 x analogue (4...20 / 20...4 mA, scalable) · DCPNP/NPN

Aseptoflex Vario Display unit -0.005...0.1 4 30 18...32 9 10 PG2789

Aseptoflex Vario Display unit -0.0124...0.25 10 30 18...32 9 10 PG2798

Aseptoflex Vario Display unit -1...1 10 30 18...32 9 10 PG2799

Aseptoflex Vario Display unit -0.05...1 10 30 18...32 9 10 PG2797

Aseptoflex Vario Display unit -0.124...2.5 20 50 18...32 9 10 PG2796

Level sensors

130www.ifm.com

Sensors for oils and coolants, LI20xx: approval to the German overspill standard WHG, section 19

Type Probe length

[mm]

Output Ub

[V]

Mediumtemperature

[°C]

Iload

[mA]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function · DC PNP

132normally open / closed

programmable10...36 – 200 8 11 LI5141

273normally open / closed

programmable10...36 – 200 8 11 LI5142

481normally open / closed

programmable10...36 – 200 8 11 LI5143

737normally open / closed

programmable10...36 – 200 8 11 LI5144

Accessories for level sensors LK, LR, LT, LL, LI

Type Description Orderno.

Flange plate · 73-90 / G ¾ · for level sensors LR · according to DIN 24557 · Housing materials: flange: stainless steel / sealing: NBR E43201

Flange plate · 65-80 / G ¾ · for level sensors LR · Housing materials: flange: stainless steel E43202

Probe · Probe length: 240 mm · for level sensors LR · Housing materials: stainless steel E43203

Probe · Probe length: 450 mm · for level sensors LR · Housing materials: stainless steel E43204

Probe · Probe length: 700 mm · for level sensors LR · Housing materials: stainless steel E43205

Probe · Probe length: 1000 mm · for level sensors LR · Housing materials: stainless steel E43207

Probe · Probe length: 1200 mm · for level sensors LR · Housing materials: stainless steel E43208

Probe · Probe length: 1400 mm · for level sensors LR · Housing materials: stainless steel E43209

Protective cover · for LK / LL / LR / LT sensors · Housing materials: PP E43910

Level sensors

131www.ifm.com

Accessories for level sensors PA, PG, PI, PN, PS, PY

Type Description Orderno.

Protective cover · for fluid sensors with connector M12 · Housing materials: polyurethane E30006

Protective cover · for fluid sensors · stainless steel with transparent Teflon window · Housing materials: stainless steel 316Ti / 1.4571/ PFA / EPDM / ventilation strip: Teflon film 0.32 mm / O-ring: EPDM

E30104

Adapter · G ¼ - G ¼ · Housing materials: stainless steel / FPM E30007

Cable clamp fastener · for submersible pressure transmitter PS3 · Housing materials: steel / plastics E30399

Filter element · for submersible pressure transmitter PS3 · for fixing on the capillary tube E30400

Splitter box · with ventilation and terminal block · for submersible pressure transmitter PS3 · Housing materials: plastics E30401

Additional weight · for submersible pressure transmitter PS3 · Housing materials: stainless steel 316Ti / 1.4571 E30402

Welding adapter · Ø 50 mm · with Aseptoflex thread · Housing materials: stainless steel 316L / 1.4404 / O-ring: FPM FDA compliant E30052

Aseptoflex adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex adapter · Housing materials: stainless steel 316L / 1.4404 E33001

Welding adapter · Ø 50 mm · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housing materials: stainless steel316L / 1.4435

E30122

Aseptoflex Vario adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housingmaterials: stainless steel 316L / 1.4435

E33201

Aseptoflex Vario adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex Vario adapter · Metal to metal seal · Housingmaterials: stainless steel 316L / 1.4435

E33701

Level sensors

132www.ifm.com

Wiring diagrams

1

L+

L3 BU

4 BK

2 WH

1 BN

Out-OPOut 2

4:2:

2

2

L

L+4

1

3Out 1Out 2

4:2:

3

Out-OP / Out 4

3

4

2

5

6

Out 1

Out 3

L+1

n.c.7

Out 2

L

4

L+

LOUT1OUT2

4:2:

4

2

1

3

5

L+

Ln.c.Out 4

Out 1Out 2

124

673

Out 35

6

BN

GY

WHL+

L

7

L+

L

1

2

8

L+

L

1

4

3

9

4

1

3

2L+

L

2

1

3

4L+

L

10

4

L

L+2

1

3Out 1Out 2

4:2:

4

L

L+2

1

3Out 1Out 2

4:2:

4

1

3

2L+

LOut 1Out 2

4:2:

2

1

3

4L+

LOut 1Out 2

4:2:

11

4

1

3

2L+

L

L

P

2

L+

L

1

2

1

1: Normal operation, 2: Programming operation (P = communi-cation via EPS / FDT interface)

Scale drawings - CAD download: www.ifm.com

1

30,5

64

M12

x1

4 3I1L

16

50

57A

I2

32

1

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming buttons, 4:Housing connection (flat-pin connector 6.3 mm following DIN 46244)

Level sensors

133www.ifm.com

Scale drawings - CAD download: www.ifm.com

2

I1

L

50

57A

I2

32

1

7687

30

63

M12

x1G 43

8 6

32

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching sta-tus), 3: Programming buttons

3

30

63

M12

x1

G 43

8 6

32

I1

L

50

57A

I2

32

1

7687

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching sta-tus), 3: Programming buttons

4

91,5

34

27

1,3

21,5

2 3

1

30

48

57,3

G

M12

x1

14

1 4/

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching sta-tus), 3: Programming button

5

91,5

34

27

1,3

21,5

2 3

1

30

47

57,3

G

M12

x1

14

1 4/

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching sta-tus), 3: Programming button

6

100

27

7

75

M12 x130

30

27

1,3

21,5

14

G 41

8

119

34

14,5

2 3

36

1

48

36

47

85M

12x1

4 5

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4:Aseptoflex sealing edge, 5: Aseptoflex thread

Level sensors

134www.ifm.com

Scale drawings - CAD download: www.ifm.com

9

16,8

G1

64

M12

x1

105,

852

,8

50

34

1

2 3

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button

10

24

3

153

16,8

100

2

1

57

60,5

M12

x1

G1

1: Analogue display, 2: 4-digit alphanumeric display, 3: Programmingbutton

11

L

16

53

M12

x1

LED

21,3

1

16,6

A

1: Programming buttons

Level sensors

135www.ifm.com

136

Flow sensors

Selection chart Page

Magnetic-inductive flow sensors with integrated temperature measurement (sealingmaterial EPDM) 139

Magnetic-inductive flow sensors (sealing material FKM) 139

Compact housings for adapters for flow monitoring 139

Compact designs for adapter with flow and temperature monitoring 140

Compact housings for adapters for hygienic and wet areas 140

Flow sensors for connection to control monitors, industrial applications 140

Flow sensors for connection to control monitors, industrial applications, titanium housing 140

Control monitors for industrial applications 141

Flow sensors for connection to control monitors with ATEX approval 141

Control monitors with ATEX approval 142

Air flow monitors 142

Compressed air meters 142

Compressed air meter for special gases 143

Inline sensor for small dosing quantities of water and aqueous solutions 143

Ultrasonic flow rate sensors for liquids (water, glycol solutions, oils) 143

Accessories for flow sensors and control monitors 143 - 144

Flange adapters for flow sensors 144 - 145

Accessories for volumetric flow sensors 145

Grounding clamps for magnetic-inductive volumetric flow sensors 145

Wiring diagrams 145 - 146

Scale drawings - CAD download: www.ifm.com 146 - 150

137www.ifm.comwww.ifm.com

For liquids and gases.

Special versions for food applications and hazardous areas.

Optional fittings for variable process connection.

Flow monitoring also for aggressive media.

Flow sensors

In almost all fields of process and plant engineering liquids or gases are used forcoolant and lubricant supply of machines and units, ventilation of installations andbuildings and the processing of products. In case of no flow of these media consid-erable damage and downtime may result. Thus it is very important to monitor thatthese media are at the right place at the right time and in sufficient quantities. Inmodern installations electronic flow monitors are used for this purpose. They workwithout wear and tear and without mechanical components. This guarantees reliablemonitoring even in case of difficult media over a long period.

Operating principle

Electronic flow sensors from ifm electronic operate with different measurement tech-niques.

They meet all requirements from a simple monitoring function to the exact detectionof flow quantities.

Harmonised operating menus ensure that operators who use different flow sensorscan quickly and precisely carry out settings on the sensors.

Some flow sensors feature an integrated temperature monitor which makes anadditional measuring point unnecessary. This enables to control processes in theoptimum operating status especially with regard to energy savings.

Analogue, binary and pulse outputs offer various possibilities to process the mea-sured data. Due to the flexible programming by means of pushbuttons the flow sen-sors can be adapted to different conditions. The sensors are mounted via adapters.

Monitoring very smallflow rates: Flow moni-tor with flow adapter.

Optimisedconsumption ofcompressed air.

Flow sensors

138www.ifm.com

Magnetic-inductive flow sensors with integrated temperature measurement (sealing material EPDM)

Type Processconnection

Measuringrange

[l/min]

Mediumtemperature

[°C]

Pressurerating

[bar]

Responsetime

[s]

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programm-

G½ 0.25...25.00 -10...70 16 < 0.150 19...30 1 1 SM6100

G¾ 0.5...50.0 -10...70 16 < 0.150 19...30 1 2 SM7100

G1 0.7...100.0 -10...70 16 < 0.150 19...30 1 3 SM8100

Magnetic-inductive flow sensors (sealing material FKM)

Type Processconnection

Measuringrange

[l/min]

Mediumtemperature

[°C]

Pressurerating

[bar]

Responsetime

[s]

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 4...20 mA analogue · DC

G½ 0...25 -10...70 16 < 0.150 19...30 2 4 SM6050

Compact housings for adapters for flow monitoring

Type Setting rangeliquids / gases

[cm/s]

Greatestsensitivity

[cm/s]

Mediumtemperature

[°C]

Pressurerating[bar]

Responsetime[s]

Ub

[V]

Draw-ingno.

Orderno.

M12 connector · Wiring diagram no. 3

3...300 / 200...3000 3...100 / 200...800 -25...80 30 1...10 19...36 5 SI5000

1/2“ UNF-Connector · Wiring diagram no. 4

3...300 / 200...3000 3...100 / 200...800 -25...80 300 1...10 85...265 6 SI5006*

M12 connector · Wiring diagram no. 2

3...300 / - 3...100 -25...80 / - 300 1...10 19...36 7 SI5004

M12 connector · Wiring diagram no. 5

3...300 / 200...3000 3...100 / 200...800 -25...80 300 1...2 / 1...10 19...36 7 SI5010

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 5 A (fast acting). Recommendation: check the unit for reliable function after a shortcircuit.

Flow sensors

139www.ifm.com

Compact designs for adapter with flow and temperature monitoring

Type Setting rangeliquids / gases

[cm/s]

Greatestsensitivity

[cm/s]

Mediumtemperature

[°C]

Pressurerating[bar]

Responsetime[s]

Ub

[V]

Draw-ingno.

Orderno.

M12 connector · Wiring diagram no. 6

3...300 / 200...3000 3...100 / 200...800 -25...80 300 1...10 19...36 7 SI5007

Compact housings for adapters for hygienic and wet areas

Type Setting rangeliquids / gases

[cm/s]

Greatestsensitivity

[cm/s]

Mediumtemperature

[°C]

Pressurerating[bar]

Responsetime[s]

Ub

[V]

Draw-ingno.

Orderno.

M12 connector · Wiring diagram no. 3

3...300 / 200...3000 3...100 / 200...800 -25...95 30 1...10 19...36 8 SI6600

3...300 / 200...3000 3...100 / 200...800 -25...95 30 1...10 19...36 9 SI6700

3...300 / 200...3000 3...100 / 200...800 -25...95 30 1...10 19...36 10 SI6800

Flow sensors for connection to control monitors, industrial applications

Type Setting rangeliquids / gases

[cm/s]

Greatestsensitivity

[cm/s]

Mediumtemperature

[°C]

Responsetime[s]

Max. T0gradient[K/min]

Pressurerating[bar]

Draw-ingno.

Orderno.

M12 connector · Wiring diagram no. 7

3...300 / 200...3000 3...60 / 200...800 -25...80 1...10 30 30 11 SF6200

3...300 / 200...3000 3...60 / 200...800 -25...80 1...10 300 300 12 SF5200

Cable 6 m · Wiring diagram no. 8

3...300 / 200...3000 3...60 / 200...800 -25...80 1...10 300 300 13 SF5350

Flow sensors for connection to control monitors, industrial applications, titanium housing

Type Setting rangeliquids / gases

[cm/s]

Greatestsensitivity

[cm/s]

Mediumtemperature

[°C]

Responsetime[s]

Max. T0gradient[K/min]

Pressurerating[bar]

Draw-ingno.

Orderno.

M12 connector · Wiring diagram no. 7

3...300 / 200...3000 3...60 / 200...800 -25...80 1...10 300 300 12 SF5700

Cable 6 m · Wiring diagram no. 8

3...300 / 200...3000 3...60 / 200...800 0...120 / 0...100 1...10 300 300 13 SF5800

Flow sensors

140www.ifm.com

Control monitors for industrial applications

Type Ub / Tolerance

[V] / [%]

Currentconsumpt.

[mA]

Powerconsumpt.

[VA]

Power-ondelay time

[s]

Outputwhen flow is

present

Outputwhen temp. is exceeded

Outputin case of

wire break

Draw-ingno.

Orderno.

Combicon connector · Wiring diagram no. 13

/ -5 /+10 – 4 10...80 relay energised relay energised relay de-energised 14 SN0150*

Combicon connector · Wiring diagram no. 14

24 DC / +10 / -20

90 – 10...80 relay energised relay energised relay de-energised 14 SR0150*

M12 connector · Wiring diagram no. 3

19...36 DC 70 – 10no / nc

programmable– – 15 SR5900

1/2“ UNF-Connector · Wiring diagram no. 4

85...265 AC / -5/ +10

– < 3.5 10no / nc

programmable– – 16 SR5906*

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, Note: miniature fuse to IEC60127-2 sheet 1,. Recommendation: check the unit for relia-ble function after a short circuit.

Flow sensors for connection to control monitors with ATEX approval

Type Setting rangeliquids / gases

[cm/s]

Greatestsensitivity

[cm/s]

Mediumtemperature

[°C]

Responsetime[s]

Max. T0gradient[K/min]

Pressurerating[bar]

Draw-ingno.

Orderno.

Cable 6 m · Wiring diagram no. 9

3...300 / 200...2000 3...60 / 200...800 -20...60 1...10 15 300 17 SF211A

3...300 / 200...2000 3...60 / 200...800 -20...70 1...10 15 30 18 SF221A

3...300 / 200...2000 3...60 / 200...800 -20...70 1...10 15 30 19 SF321A

M12 connector · Wiring diagram no. 10

3...300 / 200...2000 3...60 / 200...800 -20...70 1...10 15 30 20 SF320A

Flow sensors

141www.ifm.com

Control monitors with ATEX approval

Type Ub / Tolerance

[V] / [%]

Currentconsumpt.

[mA]

Powerconsumpt.

[VA]

Power-ondelay time

[s]

Outputwhen flow is

present

Outputwhen temp. is exceeded

Outputin case of

wire break

Draw-ingno.

Orderno.

15 terminals...2.5 mm²

230 AC / ± 10 – 5 30 relay energised – relay de-energised 21 SN2301*

110 AC / ± 10 – 5 30 relay energised – relay de-energised 21 SN2302*

24 DC / ± 10 125 – 30 relay energised – relay de-energised 21 SR2301*

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, Wire break monitoring. Recommendation: check the unit for reliable function after ashort circuit.

Air flow monitors

Type Setting rangeliquids / gases

[cm/s]

Greatestsensitivity

[cm/s]

Mediumtemperature

[°C]

Responsetime[s]

Ub / tolerance

[V] / [%]

Draw-ingno.

Orderno.

Cable 2 m · Wiring diagram no. 11

100...1000 100...400 -10...50 3...60 80...250 AC/DC 22 SL0101*

Cable 2 m · Wiring diagram no. 12

100...1000 100...400 -10...50 3...60 24 DC ± 25 % 22 SL5101

* Note for AC and AC/DC units

Miniature fuse to IEC60127-2 sheet 1, ≤ 5 A (fast acting). Recommendation: check the unit for reliable function after a shortcircuit.

Compressed air meters

Type Setting range

[Nm3/h]

Mediumtemperature

[°C]

Pressurerating

[bar]

Responsetime

[s]

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programm-able or analogue (4...20 mA scaleable) · DC PNP

0.14...15.00 0...60 16 < 0.1 19...30 15 23 SD5000

0.7...75.0 0...60 16 < 0.1 19...30 15 24 SD6000

2.0...225.0 0...60 16 < 0.1 19...30 15 25 SD8000

3.5...410.0 0...60 16 < 0.1 19...30 15 26 SD9000

6...700 0...60 16 < 0.1 19...30 15 27 SD2000

Flow sensors

142www.ifm.com

Compressed air meter for special gases

Type Setting range

[Nm3/h]

Mediumtemperature

[°C]

Pressurerating

[bar]

Responsetime

[s]

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programm-able or analogue (4...20 mA scaleable) · DC PNP

Ar: 0.8...118.2 / CO2: 0.5...71.7 / N2:0.5...73.0 Nm³/h

0...60 16 < 0.1 19...30 15 24 SD6100

Inline sensor for small dosing quantities of water and aqueous solutions

Type Processconnection

Measuring range

[ml/min]

Display range

[ml/min]

Pressurerating[bar]

Mediumtemp.[°C]

Draw-ingno.

Orderno.

M12 connector · Wiring diagram no. 15

G1/8 1...200 0...240 10 0...60 28 SQ0500

Ultrasonic flow rate sensors for liquids (water, glycol solutions, oils)

Type Processconnection

Measuringrange

[l/min]

Mediumtemperature

[°C]

Pressurerating

[bar]

Responsetime

[s]

Ub

[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programm-able or analogue (4...20 mA / 0...10 V, scaleable) · DC PNP/NPN

G¾ 0.1...50.0 -10...80 16 < 0.250 19...30 1 29 SU7000

G1 0.2...100.0 -10...80 16 < 0.250 19...30 1 30 SU8000

G1¼ 0.4...200.0 -10...80 16 < 0.250 19...30 1 31 SU9000

Accessories for flow sensors and control monitors

Type Description Orderno.

Adapter · M18 x 1.5 - G ½ · Insertion depth of the probe of SID, SFD, TN: · 21 mm · Housing materials: titanium E40114

Adapter · M18 x 1.5 - G ¼ · Insertion depth of the probe of SID, SFD, TN: · 13.5 mm · Housing materials: titanium E40115

Adapter · M18 x 1.5 - M12 x 1 · Insertion depth of the probe of SID, SFD, TN: · 13.5 mm · Housing materials: titanium E40128

Flow sensors

143www.ifm.com

Type Description Orderno.

Adapter · M18 x 1.5 - M12 x 1 · Insertion depth of the probe of SID, SFD, TN: · 13.5 mm · Housing materials: stainless steel 316L /1.4404

E40101

Adapter · M18 x 1.5 - G ¼ · Insertion depth of the probe of SID, SFD, TN: · 13.5 mm · Housing materials: stainless steel 316L /1.4404

E40099

Adapter · M18 x 1.5 - G ½ · Insertion depth of the probe of SID, SFD, TN: · 21 mm · Housing materials: stainless steel 316L / 1.4404 E40096

Welding adapter · M18 x 1.5 - Ø 23 mm · Insertion depth of the probe of SID, SFD, TN: · 21 mm · Housing materials: PE-100 E40138

Welding adapter · M18 x 1.5 - Ø 24 mm · Insertion depth of the probe of SID, SFD, TN: · 15 mm · Housing materials: stainless steel316L / 1.4404

E40124

Flow adapter (for low flow rates) · M12 x 1 - G 1/8 · for flow sensors and compact flow monitors with adapter · Housing materials:stainless steel 316L / 1.4404

E40129

Flow adapter (for low flow rates) · G ¼ - G 1/8 · for flow sensors and compact flow monitors · ¼“ · Housing materials: PVDF E40057

Flange adapters for flow sensors

Type Description Orderno.

Aseptoflex Vario adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housingmaterials: stainless steel 316L / 1.4435

E33201

Aseptoflex Vario adapter · Clamp · 2“ · ISO 2852 · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housingmaterials: stainless steel 316L / 1.4435

E33202

Aseptoflex Vario adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex Vario adapter · Metal to metal seal · Housingmaterials: stainless steel 316L / 1.4435

E33701

Aseptoflex Vario adapter · Clamp · 2“ · ISO 2852 · for units with Aseptoflex Vario adapter · Metal to metal seal · Housing materials:stainless steel 316L / 1.4435

E33702

Aseptoflex Vario adapter · Varivent type N · DN40 (1.5“), D = 68 · for units with Aseptoflex Vario adapter · Sealing by sealing ring ·Housing materials: stainless steel 316L / 1.4435

E33222

Aseptoflex Vario adapter · Varivent type F · DN25 (1“), D = 50 · for units with Aseptoflex Vario adapter · Metal to metal seal ·Housing materials: stainless steel 316L / 1.4435

E33721

Flow sensors

144www.ifm.com

Type Description Orderno.

Aseptoflex Vario adapter · Varivent type N · DN40 (1.5“), D = 68 · for units with Aseptoflex Vario adapter · Metal to metal seal ·Housing materials: stainless steel 316L / 1.4435

E33722

Welding adapter · Ø 50 mm · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housing materials: stainless steel316L / 1.4435

E30122

Accessories for volumetric flow sensors

Type Description Orderno.

Adapter · G ½ - R ½ · for flow monitor type SM6 · flat seal · Housing materials: stainless steel 316Ti / 1.4571 · Pack quantity: 2 E40199

Adapter · G ½ - G ¾ · for flow monitor type SM6 · flat seal · Housing materials: high-grade stainless steel E40189

Grounding clamps for magnetic-inductive volumetric flow sensors

Type Description Orderno.

Grounding clamp G½ · for flow monitor type SM6 · Housing materials: stainless steel E40196

Wiring diagrams

1

4

1

3

2 OUT2/InD

L+

L

BN

BUOUT1

WH

BK

2

L+

L3

2

4

1

n.c.

n.c. = not connected

3

L+

L

1

4

3

4

1

3

4

2

5

n.c.

L1

N

Out

5

P

L+1

4

3

2L

P = programming wire (forremote adjustment)

6

L

L+

3

2

4

1

S2 S1

7

2 WH

1 BN

4 BK

3 BU

5 GY

8

BU

BK

BN

WH

GY

9

BN

WH

BK

BU

123

789

GY

VS2000 Exi

10

123

789

VS2000 Exi

1 BN

2 WH

4 BK

3 BU

5 GY

11

BN

WH

BU

BK

L1

N

L+

L

12

BN

WH

BU

BKL+

L

Flow sensors

145www.ifm.com

Wiring diagrams

13

ACLN

12

11

10

9

8

7

6

5

421

19

18

17

5

4

1

3

2

GY

BK

BN

BU

WH

20

21

22

23

24

1

2

35

4

1: Flow monitoring, 2: Wire break monitoring, 3: Temperaturemonitoring, 4: Power-on delay time, 5: Selection liquid / gas

14

12

11

10

9

8

7

6

5

421

19

18

17

5

4

1

3

2

GY

BK

BN

BU

WH

20

21

22

23

24

1

2

35

4

DCL+L

1: Flow monitoring, 2: Wire break monitoring, 3: Temperaturemonitoring, 4: Power-on delay time, 5: Selection liquid / gas

15

L+

LOut 2Out 1

2:4: 3

4

2

1

L

L+

Out 2Out 1

2:4: 3

4

2

1

Scale drawings - CAD download: www.ifm.com

1

11073

M12 x1

16

G G2

1

21

M12 x1

54

2

G4

3

G4

3

11073

M12 x1

19

M12 x1

54

3

G1

G1

11073

M12 x1

19

M12 x1

54

4

11073

M12 x1

16

G G2

1

21

M12 x1

54

5

22

1 2

113

60 65

14

7,7

45

50

27

63

M12

x1

1: LED display, 2: setting pushbutton

Flow sensors

146www.ifm.com

Scale drawings - CAD download: www.ifm.com

6

22

1 2

113

60 65

14

8,2

4550

27

63

" 20U

NF

2A2

1

1: LED display, 2: setting pushbutton

7

22

1 2

113

60 65

14

8,2

45

50

27

63

M12

x1

1: LED display, 2: setting pushbutton

8

M12

x1

34

7,7

50

2071

119

27

63

1: LED display, 2: setting pushbutton, 3: G1/Aseptoflex Vario thread

9

M12

x1

34

7,710,8

50

3815

8913

7

27

63

1: LED display, 2: setting pushbutton, 3: G1/Aseptoflex Vario thread

10

M12

x1

34

7,710,8

50

5515

106

154

27

63

1: LED display, 2: setting pushbutton, 3: G1/Aseptoflex Vario thread

11

7,745

15

M12

x1

217

10

2025 146

12

M12

x1

8272

22

14

8,2

44

19 1

1: internal thread M18 x 1.5

Flow sensors

147www.ifm.com

Scale drawings - CAD download: www.ifm.com

13

8672

22

14

8,2

44

19 1

1: internal thread M18 x 1.5

14

103,5

35,5

25

100

2

1

LEDs

LEDs

1 2 3 4

5 6 7 8

9 10 11 12

21 22 23 24

17 18 19 20

1: Potentiometer (switch point flow), 2: Potentiometer (switch pointtemperature)

15

27

64

M12

x1

4

1 2

835248

50

19,7

3

1: LED display, 2: setting pushbutton, 3: connection for voltage sup-ply and output signals, 4: connection for flow sensor

16

27

64

4

1 2

835248

50

19,7

3

" 20U

NF

2A2

1

1: LED display, 2: setting pushbutton, 3: connection for voltage sup-ply and output signals, 4: connection for flow sensor

17

17

57

122713

8,2

G4

1

18

17

57

122713

7,7G

41

19

124515

80

27

G2

1

7,7

20

M12

x1

124515

75

7,727

G2

1

21

45

78

1 2

19 20 21

13 14 15 16 17 18

3

97 8

+

120

35,5

1

1: mounting on DIN rail

22

140133

11332

23

2 LED

pot.2 LED

Flow sensors

148www.ifm.com

Scale drawings - CAD download: www.ifm.com

23

182,3

21,3

M12

x1

100111

74,5

G1

4 /

45

1 2

G1

4 /

60 20

31

3

1: 4-digit alphanumeric display, 2: Programming buttons, 3: hole forM5 fixing screw

24

R

210300

16,1

21,3

M12

x1

100111

76,8

45

1 2

1: 4-digit alphanumeric display, 2: Programming buttons

25

475375

27,3

33,7

R 1

M12

x1

100111

88,5

45

1 2

1: 4-digit alphanumeric display, 2: Programming buttons

26

39R

112

275475

42

100111

M12

x1

120

451 2

1: 4-digit alphanumeric display, 2: Programming buttons

27

133

451 2

54

R2 51

100111

M12

x1

275475

1: 4-digit alphanumeric display, 2: Programming buttons

28

114

4,5

3710

M12

x1

100

125

111117

56

45

G8

1

48

65

1: 4-digit alphanumeric display, 2: Programming buttons, 3: flowconditioner

29

G4

3

G4

3

11096

100

80,5

M12

x1

installation length with pipe adapter E40151 / E40154: 185 mm

Flow sensors

149www.ifm.com

Scale drawings - CAD download: www.ifm.com

30

80,5

M12

x1

G1

13096

100

G1

installation length with pipe adapter E40152 / E40155: 205 mm,installation length with pipe adapter E40153 / E40156: 215 mm

31

80,5

M12

x1

26

48

13096

100

G1

41

G1

41

Flow sensors

150www.ifm.com

Flow sensors

151

152

Pressure sensors

Selection chart Page

Sensors with switching outputs and analogue outputs and display 155

Sensors with switching outputs and display 155

PK sensors with mechanical setting and switching outputs 155

PT sensors for mobile applications with analogue outputs 156

PA / PPA sensors for industrial applications with analogue outputs / AS-i 156

Sensors for hydrostatic level monitoring 156

PI sensors for hygienic and wet areas, 2-wire with analogue output 157

PI sensors for hygienic and wet areas with switching and analogue output 157

Full-metal sensors for hygienic and wet areas with switching output and analogue output 157

Electronic contact manometers for hygienic and wet areas with switching output and ana-logue output 158

Sensors for pump monitoring 158

PF sensors for hygienic and wet areas with switching and analogue output 158

PL / PM sensors without display for hygienic and wet areas with analogue output 159

Sensors for hygienic and wet areas with Profibus PA Interface 159

Fixing components for pressure sensors 159

Accessories and software 159 - 160

Adapters and accessories for adapters 160

Flange adapters 160 - 161

Wiring diagrams 161 - 162

Scale drawings - CAD download: www.ifm.com 162 - 164

153www.ifm.comwww.ifm.com

Transmitters or sensors with integrated control monitor.

Units with special design for hygienic applications.

Measuring principles with overload protection and a good long-term stability.

Measuring range from -1…600 bar.

Variable process connection and sealing technology via adapter.

Pressure sensors

ifm offers a wide range of electronic pressure and vacuum sensors to meet the re-quirements of various industrial applications. The ceramic-capacitive measuring cell,tried and tested a million times, is complemented by a stainless steel measuring cellwith thick-film wire strain gauges (series PK, PV, PT) and a piezoresistive measuringtechnique (for pneumatic applications).

All units have robust housings and do not require moving parts such as pistons orsprings. The result: the sensors are extremely shock and vibration resistant and ope-rate without any wear or maintenance.

The tried and tested ceramic-capacitive measuring principle is corrosion-resistant andlong-term stable. In the long run this guarantees continuous accuracy of the mea-sured values. The sensors are resistant to dynamic pressure peaks and guarantee highoverload resistance even in the case of extreme pressure peaks that occur for exam-ple with fast closing valves.

Units with wire strain gauge in thick-film technology on a stainless steel measuringcell are distinguished by their very compact and robust design. They can be used inalmost all industrial areas. The welded stainless steel measuring cell without any sealsensures a high degree of safety, in particular for applications with gas pressures ofup to 400 bar as well as in air-conditioning and refrigerating technology whereaggressive coolants (freons) are used.

The display: The7-segment displayshows the systempressure at a glance.

Separate display /programming unit

PP2001.

Pressure sensors

154www.ifm.com

Sensors with switching outputs and analogue outputs and display

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) · DC PNP/NPN

G¼ I Display unit -0.25...0.25 10 30 18...32 7 1 PY2068

M12 connector · Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 xanalogue (4...20 mA / 0...10 V; scaleable 1:4) · DC PNP/NPN

G¼ I Display unit 0...400 600 1000 20...30 8 2 PN2020

G¼ I Display unit 0...250 400 850 20...30 8 3 PN2021

G¼ I Display unit 0...100 300 650 20...30 8 3 PN2022

G¼ I Display unit -1...25 100 350 20...30 8 3 PN2023

G¼ I Display unit -1...10 75 150 20...30 8 3 PN2024

G¼ I Display unit -0.125...2.5 20 50 20...30 8 3 PN2026

G¼ I Display unit -0.05...1 10 30 20...30 8 3 PN2027

G¼ I Display unit -1...1 20 50 20...30 8 3 PN2009

G¼ I Display unit -0.5...0.5 10 30 20...30 8 3 PN2069

G¼ I Display unit -0.0125...0.25 10 30 20...30 8 3 PN2028

Sensors with switching outputs and display

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M8 connector · Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x nor-mally closed (diagnostic function) · DC PNP

G 1/8 I Display unit -1...1 20 30 18...32 1 4 PQ7809

G 1/8 I Display unit -1...10 20 30 18...32 1 4 PQ7834

PK sensors with mechanical setting and switching outputs

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function normally open / closed complementary · DC PNP

G¼ A / M5 I Operation 0...400 600 1600 9.6...32 2 5 PK6520

G¼ A / M5 I Operation 0...250 400 1000 9.6...32 2 5 PK6521

G¼ A / M5 I Operation 0...100 200 1000 9.6...32 2 5 PK6522

G¼ A / M5 I Operation 0...25 60 500 9.6...32 2 5 PK6523

G¼ A / M5 I Operation 0...10 25 300 9.6...32 2 5 PK6524

Pressure sensors

155www.ifm.com

PT sensors for mobile applications with analogue outputs

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 4...20 mA analogue · DC

G¼ A – 0...400 600 1600 8.5...32 3 6 PT3550

G¼ A – 0...250 400 1000 8.5...32 3 6 PT3551

G¼ A – 0...100 200 1000 8.5...32 3 6 PT3552

G¼ A – 0...25 60 600 8.5...32 3 6 PT3553

G¼ A – 0...10 25 300 8.5...32 3 6 PT3554

M12 connector · Output function 0...10 V analogue · DC

G¼ A – 0...400 600 1600 16...32 4 6 PT9550

G¼ A – 0...250 400 1000 16...32 4 6 PT9551

G¼ A – 0...100 200 1000 16...32 4 6 PT9552

G¼ A – 0...25 60 600 16...32 4 6 PT9553

G¼ A – 0...10 25 300 16...32 4 6 PT9554

PA / PPA sensors for industrial applications with analogue outputs / AS-i

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 4...20 mA analogue · DC

G¼ I – 0...600 800 1200 9.6...32 3 7 PA3060

G¼ I – 0...400 600 1000 9.6...32 3 7 PA3020

G¼ I – 0...250 400 850 9.6...32 3 8 PA3021

G¼ I – 0...100 300 650 9.6...32 3 8 PA3022

G¼ I – 0...25 150 350 9.6...32 3 8 PA3023

G¼ I – 0...10 75 150 9.6...32 3 8 PA3024

G¼ I – 0...2.5 20 50 9.6...32 3 8 PA3026

G¼ I – 0...1 10 30 9.6...32 3 8 PA3027

G¼ I – 0...0.25 10 30 9.6...32 3 8 PA3028

G¼ I – -1...0 10 30 9.6...32 3 8 PA3029

Sensors for hydrostatic level monitoring

Type Measuringrange[bar]

Cable length /material

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

Output 4...20 mA analogue · Wiring diagram no. 5

0...0.253 m

PUR cable2 2.4 10...30 5 9 PS3208

0...0.610 m

PUR cable4 4.8 10...30 5 9 PS3407

0...112 m

PUR cable5 6 10...30 5 9 PS3417

Pressure sensors

156www.ifm.com

PI sensors for hygienic and wet areas, 2-wire with analogue output

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 4...20 (20...4) mA analogue (scaleable 1:4) · DC

Aseptoflex Display unit -1...25 100 350 20...32 9 10 PI1093

Aseptoflex Display unit -1...10 50 150 20...32 9 10 PI1094

Aseptoflex Display unit -1...4 30 100 20...32 9 10 PI1095

Aseptoflex Display unit -0.124...2.5 20 50 20...32 9 10 PI1096

Aseptoflex Display unit -0.05...1 10 30 20...32 9 10 PI1097

Aseptoflex Display unit -1...1 10 30 20...32 9 10 PI1099

G1 A Display unit -1...25 100 350 20...32 9 11 PI1693

G1 A Display unit -1...10 50 150 20...32 9 11 PI1694

G1 A Display unit -1...4 30 100 20...32 9 11 PI1695

G1 A Display unit -0.124...2.5 20 50 20...32 9 11 PI1696

G1 A Display unit -0.05...1 10 30 20...32 9 11 PI1697

G1 A Display unit -0.0124...0.25 10 30 20...32 9 11 PI1698

G1 A Display unit -1...1 10 30 20...32 9 11 PI1699

PI sensors for hygienic and wet areas with switching and analogue output

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) · DC PNP/NPN

Aseptoflex Display unit -1...25 100 350 18...32 7 10 PI2093

Aseptoflex Display unit -1...10 50 150 18...32 7 10 PI2094

Aseptoflex Display unit -1...4 30 100 18...32 7 10 PI2095

Aseptoflex Display unit -0.124...2.5 20 50 18...32 7 10 PI2096

Aseptoflex Display unit -0.05...1 10 30 18...32 7 10 PI2097

Aseptoflex Display unit -0.0124...0.25 10 30 18...32 7 10 PI2098

Aseptoflex Display unit -1...1 10 30 18...32 7 10 PI2099

Full-metal sensors for hygienic and wet areas with switching output and analogue output

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed pro-grammable or 1 x analogue (4...20 / 20...4 mA, scalable) · DC PNP/NPN

Aseptoflex Vario Display unit -1...25 100 350 18...32 8 12 PI2793

Aseptoflex Vario Display unit -1...10 50 150 18...32 8 12 PI2794

Aseptoflex Vario Display unit -1...4 30 100 18...32 8 12 PI2795

Aseptoflex Vario Display unit -0.124...2.5 20 50 18...32 8 12 PI2796

Aseptoflex Vario Display unit -0.05...1 10 30 18...32 8 12 PI2797

Aseptoflex Vario Display unit -0.0124...0.25 10 30 18...32 8 12 PI2798

Aseptoflex Vario Display unit -1...1 10 30 18...32 8 12 PI2799

Aseptoflex Vario Display unit -0.005...0.1 4 30 18...32 8 12 PI2789

Pressure sensors

157www.ifm.com

Electronic contact manometers for hygienic and wet areas with switching output and analogue output

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / closed programmable + 1 x analogue (4...20 / 20...4 mA, scalable) · DCPNP/NPN

Aseptoflex Vario Display unit -1...25 100 350 18...32 7 13 PG2793

Aseptoflex Vario Display unit -1...10 50 150 18...32 7 13 PG2794

Aseptoflex Vario Display unit -1...4 30 100 18...32 7 13 PG2795

Aseptoflex Vario Display unit -0.124...2.5 20 50 18...32 7 13 PG2796

Aseptoflex Vario Display unit -0.05...1 10 30 18...32 7 13 PG2797

Aseptoflex Vario Display unit -0.0124...0.25 10 30 18...32 7 13 PG2798

Aseptoflex Vario Display unit -1...1 10 30 18...32 7 13 PG2799

Aseptoflex Vario Display unit -0.005...0.1 4 30 18...32 7 13 PG2789

G½ Display unit 0...250 600 1000 18...32 7 14 PG2451

G½ Display unit 0...100 300 700 18...32 7 14 PG2452

G½ Display unit -1...25 100 300 18...32 7 14 PG2453

G½ Display unit -1...10 50 150 18...32 7 14 PG2454

G½ Display unit -0.125...2.5 20 50 18...32 7 14 PG2456

G½ Display unit -0.05...1 10 30 18...32 7 14 PG2457

G½ Display unit -0.0125...0.25 10 30 18...32 7 14 PG2458

G½ Display unit -0.005...0.1 4 30 18...32 7 14 PG2489

Sensors for pump monitoring

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed pro-grammable or 1 x analogue (4...20 / 20...4 mA, scalable) · DC PNP

G1 A Display unit -1...25 100 350 18...32 10 11 PIM693

G1 A Display unit -1...10 50 150 18...32 10 11 PIM694

PF sensors for hygienic and wet areas with switching and analogue output

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 xanalogue (4...20 mA / 0...10 V; scaleable 1:4) · DC PNP/NPN

G1 A Switching status -1...100 200 650 20...30 8 15 PF2652

G1 A Switching status -1...25 100 350 20...30 8 16 PF2653

G1 A Switching status -0.5...10 50 150 20...30 8 16 PF2654

G1 A Switching status -0.13...2.5 20 50 20...30 8 16 PF2656

G1 A Switching status -0.05...1 10 30 20...30 8 16 PF2657

G1 A Switching status -0.013...0.25 10 30 20...30 8 16 PF2658

Pressure sensors

158www.ifm.com

PL / PM sensors without display for hygienic and wet areas with analogue output

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Output function 4...20 mA analogue · DC

Aseptoflex – -1...25 100 350 14...30 11 17 PM2053

Aseptoflex – -0.5...10 50 150 14...30 11 17 PM2054

Aseptoflex – -0.05...1 10 30 14...30 11 17 PM2057

Aseptoflex – -0.0125...0.25 10 30 14...30 11 17 PM2058

Sensors for hygienic and wet areas with Profibus PA Interface

Type Processconnection

Display

LED

Measuringrange[bar]

Poverload

max. [bar]

Pbursting

min. [bar]

UbDC[V]

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector · Profibus PA, electrically isolated · Wiring diagram no. 6

Aseptoflex – -1...10 50 150 9...32 6 18 PMP094

Aseptoflex – -1...4 30 100 9...32 6 18 PMP095

Aseptoflex – -0.124...2.5 20 50 9...32 6 18 PMP096

Aseptoflex – -0.05...1 10 30 9...32 6 18 PMP097

Fixing components for pressure sensors

Type Description Orderno.

Mounting clamp · Ø 34 mm · Housing materials: PBT E10017

Accessories and software

Type Description Orderno.

Protective cover · for fluid sensors with connector M12 · Housing materials: polyurethane E30006

Protective cover · for fluid sensors · stainless steel with transparent Teflon window · Housing materials: stainless steel 316Ti / 1.4571/ PFA / EPDM / ventilation strip: Teflon film 0.32 mm / O-ring: EPDM

E30104

Programming/ display unit · for EPS and IO-Link sensors · Connector · Housing materials: stainless steel 316L / 1.4404 / EPDM/X / PCcopolymer / PBT / FPM

PP2001

Protective cover · with lead seal option · for pressure sensors type PK · for temperature sensors type TK · for vibration monitor VK ·Housing materials: PP transparent

E30094

IO-Link interface · for parameter setting and analysis of units with DTM specification · Supported communication protocols: IO-Link(4800 and 38400 bits/s) EPS protocol (19200 bits/s) · contains ifm Container software (E30110)

E30396

Cable clamp fastener · for submersible pressure transmitter PS3 · Housing materials: steel / plastics E30399

Pressure sensors

159www.ifm.com

Type Description Orderno.

Filter element · for submersible pressure transmitter PS3 · for fixing on the capillary tube E30400

Splitter box · with ventilation and terminal block · for submersible pressure transmitter PS3 · Housing materials: plastics E30401

Additional weight · for submersible pressure transmitter PS3 · Housing materials: stainless steel 316Ti / 1.4571 E30402

Adapters and accessories for adapters

Type Description Orderno.

Adapter · G ¼ - G ¼ · Housing materials: stainless steel / FPM E30007

Adapter · G 1 - G ½ · Housing materials: stainless steel 316L / 1.4404 / sealing: FPM E30116

Flange adapters

Type Description Orderno.

Aseptoflex Vario adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housingmaterials: stainless steel 316L / 1.4435

E33201

Aseptoflex Vario adapter · Clamp · 2“ · ISO 2852 · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housingmaterials: stainless steel 316L / 1.4435

E33202

Aseptoflex Vario adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex Vario adapter · Metal to metal seal · Housingmaterials: stainless steel 316L / 1.4435

E33701

Aseptoflex Vario adapter · Clamp · 2“ · ISO 2852 · for units with Aseptoflex Vario adapter · Metal to metal seal · Housing materials:stainless steel 316L / 1.4435

E33702

Aseptoflex Vario adapter · Varivent type N · DN40 (1.5“), D = 68 · for units with Aseptoflex Vario adapter · Sealing by sealing ring ·Housing materials: stainless steel 316L / 1.4435

E33222

Aseptoflex Vario adapter · Varivent type F · DN25 (1“), D = 50 · for units with Aseptoflex Vario adapter · Metal to metal seal ·Housing materials: stainless steel 316L / 1.4435

E33721

Aseptoflex Vario adapter · Varivent type N · DN40 (1.5“), D = 68 · for units with Aseptoflex Vario adapter · Metal to metal seal ·Housing materials: stainless steel 316L / 1.4435

E33722

Pressure sensors

160www.ifm.com

Type Description Orderno.

Welding adapter · Ø 50 mm · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housing materials: stainless steel316L / 1.4435

E30122

Adapter plug · for Aseptoflex Vario adapter · Housing materials: high-grade stainless steel E30128

Aseptoflex adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex adapter · Housing materials: stainless steel 316L / 1.4404 E33001

Aseptoflex adapter · Clamp · 2“ · ISO 2852 · for units with Aseptoflex adapter · Housing materials: stainless steel 316L / 1.4404 E33002

Welding adapter · Ø 50 mm · with Aseptoflex thread · Housing materials: stainless steel 316L / 1.4404 / O-ring: FPM FDA compliant E30052

Adapter plug for welding adapter with Aseptoflex thread · Housing materials: high-grade stainless steel E30064

Wiring diagrams

1

2

L

L+4

1

3Out 1Out 2

4:2:

2

4

L

L+1

2

32:4:

3

L+

L

1

2

4

L+

L

1

3

2

5

BN

GY

WHL+

L

6

PA

PA+2

4

1

3n.c.

n.c.

7

4

1

3

2L+

L

2

1

3

4L+

L

8

4

L

L+2

1

3Out 1Out 2

4:2:

4

L

L+2

1

3Out 1Out 2

4:2:

4

1

3

2L+

LOut 1Out 2

4:2:

2

1

3

4L+

LOut 1Out 2

4:2:

Pressure sensors

161www.ifm.com

Wiring diagrams

9

4

1

3

2L+

L

L

P

2

L+

L

1

2

1

1: Normal operation, 2: Programming operation (P = communi-cation via EPS / FDT interface)

10

L+

LOut 2Out 1

2:4: 3

4

2

1

L

L+

Out 2Out 1

2:4: 3

4

2

1

11

L+

L

1

2

L+

L

1

3

2

Scale drawings - CAD download: www.ifm.com

1

91,5

34

27

1,3

21,5

2 3

1

30

48

57,3

G

M12

x1

14

1 4/

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching sta-tus), 3: Programming button

2

30

47,8

59,6

G

M12

x1

16,5

1 4/

94,1

34

27

1,3

21,5

2 3

1

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching sta-tus), 3: Programming button

3

91,5

34

27

1,3

21,5

2 3

1

30

47

57,3

G

M12

x1

14

1 4/

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching sta-tus), 3: Programming button

4

4,2

354,75

3220

4232

30

20,7

11,3

1: main pressure connection G 1/8; tightening torque max. 8 Nm,thread length max: 7.5 mm, 2: for mounting screw M4; max. tighte-ning torque 2.5 Nm, 3: LEDs (display unit / switching status), 4: 4-digit alphanumeric display, 5: Programming button

Pressure sensors

162www.ifm.com

Scale drawings - CAD download: www.ifm.com

5

61,6

12

M12 x127

2771

,6

G1 4/M5

7,5

21

1: tightening torque 25 Nm, 2: sealing FPM / DIN 3869-14

6

221

51,2

12

G1 4/

65,1

M12 x122

1: sealing FPM / DIN 3869-14, tightening torque 25 Nm

7

77,5

M12 x130

30

27

1,3

21,5

16,5

G 41

8

75

M12 x130

30

27

1,3

21,5

14

G 41

9

100

27

10

119

34

14,5

2 3

36

1

48

36

47

85M

12x1

4 5

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4:Aseptoflex sealing edge, 5: Aseptoflex thread

11

G125,4

119

41

34

2 348

27

1

47

85M

12x1

20°

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button

12

16,8

G1

64

M12

x1

105,

852

,8

50

34

1

2 3

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button

Pressure sensors

163www.ifm.com

Scale drawings - CAD download: www.ifm.com

13

24

3

153

16,8

100

2

1

57

60,5

M12

x1

G1

1: Analogue display, 2: 4-digit alphanumeric display, 3: Programmingbutton

14

3

169

22

100

2

1

24

75,5

57

M12

x1

G 21

1: Analogue display, 2: 4-digit alphanumeric display, 3: Touch button(programming button)

15

46,5

58M

12x1

41 20°

92

34

M12 x1

27,5

G125,4

1 2

1: 7-segment LED display, 2: Programming button

16

97,4

34

27,5

G125,4

48,51 2

46,5

63,1

M12

x1

41 20°

1: 7-segment LED display, 2: Programming button

17

36

107

34

15

M12 x1

121,

5

48

1 2

1: Aseptoflex sealing edge, 2: Aseptoflex thread

18

14,5

36

58

M12 x150

108 12

2,8

1 2

1: Aseptoflex sealing edge, 2: Aseptoflex thread

Pressure sensors

164www.ifm.com

Pressure sensors

165

166

Temperature sensors

Selection chart Page

Compact temperature sensors 169

Compact temperature sensors with display 169

Control monitors for temperature sensors 169 - 170

Control monitors for temperature sensors 170

Pt1000 probe sensors for standard applications 170

Pt100 probe sensors for standard applications 171

Cable sensors for standard applications 171

Cable sensors with bolt-on sensor for standard applications 171

Temperature transmitters for standard applications 171

AS-i temperature transmitters for standard applications 172

Probe sensors for hygienic and wet areas 172

Cable sensors for hygienic and wet areas 172

Temperature transmitters for hygienic and wet areas 172

AS-i temperature transmitters for hygienic and wet areas 173

Self-monitoring temperature transmitters for hygienic and wet areas 173

Profibus-Temperaturtransmitter mit ATEX-Zulassung 1G, 1/2GD, 2GD 173

Accessories for temperature sensors TN / TR 173

Accessories and software 173

Adapters 174 - 175

Thermowells for temperature sensors 175

Flange adapters 175 - 176

Wiring diagrams 176 - 177

Scale drawings - CAD download: www.ifm.com 177 - 180

167www.ifm.comwww.ifm.com

Increased process safety due to self-monitoring.

Compact units with integrated sensorsor modular systems.

Robust construction for high resistanceto shock and vibration.

Direct contact with medium orthermowell mounting.

Units with diverse redundant sensorsfor critical tasks.

Temperature sensors

The controlling and monitoring of temperatures are amongst the most importantmeasuring tasks in automation and process technology. In process technology forexample the right temperature is decisive for the quality and efficiency of the pro-cess. In automation technology an exact temperature detection is very important formonitoring installations and as protection against dangerous states. In heating andair conditioning economic and easy operation is not possible without temperaturemeasurement and control.

Operating principle

The temperature sensors of ifm electronic are based on a Pt100 or Pt1000 resistor.The measured temperature value corresponds to a change in resistance and is con-verted into an electrical analogue signal.

The microprocessor and the display make process adjustment much easier. The usercan set the values for the switch points, hysteresis and measuring range by means ofprogramming buttons even without the system temperature being applied. This en-ables installation and setup of the system within a few minutes.

Film technology is used for the electronic circuitry. A flexible, temperature-resistantand extremely resistant polyimide film is used as carrier of the SMD components.Together with a special potting method an extreme shock and vibration resistance isachieved.

From sensor to system

A complete temperature measurement system usually consists of several compo-nents. The temperature in a medium is detected by a sensor and is converted into anelectrical measured signal. The mechanical design and the dimensions of the sensorsmust vary to enable use for different media and measuring points. ifm electronicoffers a selection of robust probe sensors or types with connection cables. To indi-cate and process the measured value the sensor is connected to a separate controlmonitor.

For further processing, freely programmable switching or analogue outputs areavailable. If a local temperature display is not required, temperature transmitters arefrequently used. ifm electronic provides units with excellent response times (TAseries) that either have standard output signals or an integrated AS-i interface. Inhygienic applications the self-monitoring, calibration-free temperature transmitterTAD is an excellent choice.

Local display of thecurrent temperature.

Imperative:Temperature

detection in heatingand air conditioning.

Temperature sensors

168www.ifm.com

Compact temperature sensors

Type Measuringrange[°C]

Processconnection

Probe length

[mm]

Ub

[V]

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · Output function normally open / closed complementary · DC PNP

-25...140 G¼ A 25 9.6...32 1 / 3 1 1 TK6130

-25...140 ¼“ NPT 35 9.6...32 1 / 3 1 2 TK6330

M12 connector · Output function · DC PNP

-25...140 G¼ A 25 9.6...32 1 / 3 2 1 TK7130

-25...140 ¼“ NPT 35 9.6...32 1 / 3 2 2 TK7330

M12 connector · Output function 1 x normally open / 1 x normally closed · DC PNP

-25...140 G½ A 255 9.6...32 1 / 3 2 3 TK7480

Compact temperature sensors with display

Type Measuringrange[°C]

Processconnection

Probe length

[mm]

Ub

[V]

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V, scalable) · DCPNP/NPN

-40...150 M18 x 1.5 45 18...32 1 / 3 7 4 TN2531

M12 connector · Output function 2 x normally open / closed programmable · DC PNP/NPN

-40...150 M18 x 1.5 45 18...32 1 / 3 8 4 TN7531

Control monitors for temperature sensors

Type Measuringrange[°C]

Processconnection

Display

LED

Ub

[V]

Currentconsump.

[mA]

Iload

[mA]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · Output function 4 x normally open / closed programmable · DC PNP

-40...150 G½ A Display unit 18...28 90 < 500 9 5 TR8430

Temperature sensors

169www.ifm.com

Type Measuringrange[°C]

Processconnection

Display

LED

Ub

[V]

Currentconsump.

[mA]

Iload

[mA]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · Output function 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V, scalable) · DCPNP/NPN

-40...300 G½ A Display unit 20...30 55 250 10 5 TR2432

M12 connector · Output function 2 x normally open / closed programmable · DC PNP/NPN

-40...300 G½ A Display unit 18...32 50 250 11 6 TR7432

Control monitors for temperature sensors

Type Measuringrange[°C]

Processconnection

Display

LED

Ub

[V]

Currentconsump.

[mA]

Iload

[mA]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · Output function 4...20 mA analogue · DC

0...100 – – 20...32 – – 12 7 TP3237

Pt1000 probe sensors for standard applications

Type Measuringrange[°C]

Diameter

[mm]

Probe length

[mm]

Sensorelement

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · high-grade stainless steel

-40...150 6 160 1 x Pt 1000 1 / 3 3 8 TT1250

-40...150 6 360 1 x Pt 1000 1 / 3 3 8 TT3250

-40...150 10 160 1 x Pt 1000 1 / 3 3 9 TT1050

-40...150 10 260 1 x Pt 1000 1 / 3 3 9 TT2050

-40...150 10 560 1 x Pt 1000 1 / 3 3 9 TT5050

-40...125 8.2 44 1 x Pt 1000 1 / 3 3 10 TM9550

-40...150 10 50 1 x Pt 1000 5 / 14 3 11 TM0061

Temperature sensors

170www.ifm.com

Pt100 probe sensors for standard applications

Type Measuringrange[°C]

Diameter

[mm]

Probe length

[mm]

Sensorelement

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · high-grade stainless steel

-40...150 10 260 1 x Pt 100 1 / 3 3 9 TT2081

Cable sensors for standard applications

Type Measuringrange[°C]

Diameter

[mm]

Cablematerial

Sensorelement

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

Cable with connector 2 m · high-grade stainless steel

-40...150 Ø 6 / L = 45 FPM (Viton) cable 1 x Pt 1000 3 / 10 3 12 TS2251

-40...150 Ø 10 / L = 45 FPM (Viton) cable 1 x Pt 1000 6 / 25 3 13 TS2051

-50...250 Ø 6 / L = 50 PTFE cable 1 x Pt 100 11 / 37 3 14 TS2256

-50...250 Ø 10 / L = 50 PTFE cable 1 x Pt 100 12 / 39 3 15 TS2056

Cable with connector 5 m · high-grade stainless steel

-40...150 Ø 10 / L = 45 FPM (Viton) cable 1 x Pt 1000 6 / 25 3 13 TS5051

Cable sensors with bolt-on sensor for standard applications

Type Measuringrange[°C]

Diameter

[mm]

Cablematerial

Sensorelement

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

Cable with connector 2 m · stainless steel

-25...90 M6 / 12 x 51 PUR cable 1 x Pt 100 9 / 15 3 16 TS2229

Temperature transmitters for standard applications

Type Measuringrange[°C]

Processconnection

Probe length

[mm]

Ub

[V]

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · high-grade stainless steel · DC

-50...150 G¼ A 46.5 10...30 1 / 3 4 17 TA3131

0...140 G¼ A 46.5 10...30 1 / 3 4 17 TA3130

Temperature sensors

171www.ifm.com

AS-i temperature transmitters for standard applications

Type Measuringrange[°C]

Processconnection

Probe length

[mm]

Ub

[V]

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · high-grade stainless steel · DC

-10...150 G¼ A 46.5 18...31.6 1 / 3 5 18 TAA131

Probe sensors for hygienic and wet areas

Type Measuringrange[°C]

Diameter

[mm]

Probe length

[mm]

Sensorelement

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · high-grade stainless steel

-40...150 10 110 1 x Pt 1000 1 / 3 3 9 TT0061

-40...150 10 160 1 x Pt 1000 1 / 3 3 9 TT1061

Cable sensors for hygienic and wet areas

Type Measuringrange[°C]

Diameter

[mm]

Cablematerial

Sensorelement

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

Cable with connector 2 m · high-grade stainless steel

-40...150 Ø 10 / L = 45 FPM (Viton) cable 1 x Pt 1000 6 / 25 3 13 TS2051

Cable with connector 5 m · high-grade stainless steel

-40...150 Ø 10 / L = 45 FPM (Viton) cable 1 x Pt 1000 6 / 25 3 13 TS5051

Cable with connector 2 m · high-grade stainless steel

-50...250 Ø 10 / L = 50 PTFE cable 1 x Pt 100 12 / 39 3 15 TS2056

Temperature transmitters for hygienic and wet areas

Type Measuringrange[°C]

Processconnection

Probe length

[mm]

Ub

[V]

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · high-grade stainless steel · DC

0...100 G½ A 87.5 10...30 1 / 3 4 19 TA3437

0...140 G½ A 87.5 10...30 1 / 3 4 19 TA3430

-10...150 G½ A 87.5 10...30 1 / 3 4 19 TA3431

-10...150 Ø 6 mm 123 10...30 1.2 / 3.5 4 20 TA3231

Temperature sensors

172www.ifm.com

AS-i temperature transmitters for hygienic and wet areas

Type Measuringrange[°C]

Processconnection

Probe length

[mm]

Ub

[V]

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · high-grade stainless steel · DC

-10...150 G½ A 87.5 18...31.6 1 / 3 5 21 TAA431

Self-monitoring temperature transmitters for hygienic and wet areas

Type Measuringrange[°C]

Processconnection

Probe length

[mm]

Ub

[V]

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · Output function normally open / normally closed / heartbeat programmable, 4...20 mA analogue · DC PNP/NPN

-25...150 Aseptoflex Vario 87.5 15...32 3 / 6 13 22 TAD181

-25...150 Aseptoflex Vario 33 15...32 3 / 6 13 23 TAD981

Profibus-Temperaturtransmitter mit ATEX-Zulassung 1G, 1/2GD, 2GD

Type Measuringrange[°C]

Processconnection

Probe length

[mm]

Ub

[V]

Dynamic responseT05 / T09

[s]

Wiringdiagr.

no.

Draw-ingno.

Orderno.

M12 connector · Wiring diagram no. 6

-25...150 Aseptoflex Vario 87.5 9...32 3 / 6 6 24 TAP18A

-25...150 Aseptoflex Vario 33 9...32 3 / 6 6 25 TAP98A

Accessories for temperature sensors TN / TR

Type Description Orderno.

Mounting clamp · Ø 34 mm · Housing materials: PBT E10017

Protective cover · for fluid sensors with connector M12 · Housing materials: polyurethane E30006

Accessories and software

Type Description Orderno.

IO-Link interface · for parameter setting and analysis of units with DTM specification · Supported communication protocols: IO-Link(4800 and 38400 bits/s) EPS protocol (19200 bits/s) · contains ifm Container software (E30110)

E30396

Temperature sensors

173www.ifm.com

Adapters

Type Description Orderno.

Thread cover · Ø 26 mm - G ½ · to cover the G½ thread for installation in hygienic areas · for type TA · Housing materials: stainlesssteel 316L / 1.4404

E30090

Mounting set · for direct connection of temperature sensors TT to control monitors TR · Housing materials: stainless steel E30017

Mounting set · G ½ · for direct connection of temperature sensors TM to control monitors TR · Housing materials: stainless steel316L / 1.4404 / stainless steel

E30089

Clamp fitting · Ø 6/8/10 mm - G ½ · for temperature sensors TS / TT · Housing materials: stainless steel / FPM E30018

Clamp adapter · Ø 10 mm - G ½ · no dead space · Housing materials: stainless steel 316L / 1.4404 / FPM E34410

Welding adapter · M18 x 1.5 - Ø 24 mm · Insertion depth of the probe of SID, SFD, TN: · 15 mm · Housing materials: stainless steel316L / 1.4404

E40124

Welding adapter · G ½ - Ø 35 mm · ball · Housing materials: stainless steel 316L / 1.4404 E30055

Welding adapter · G ½ - Ø 45 mm · collar · Housing materials: stainless steel 316L / 1.4404 E30056

Welding adapter · Ø 50 mm · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housing materials: stainless steel316L / 1.4435

E30122

Progressive ring fitting for temperature sensors · Ø 10 mm - G ½ · Housing materials: stainless steel 316Ti / 1.4571 E30016

Progressive ring fitting for temperature sensors · Ø 6 mm - G ½ · Housing materials: stainless steel 316Ti / 1.4571 E30047

Adapter · M18 x 1.5 - G ½ · Insertion depth of the probe of SID, SFD, TN: · 21 mm · Housing materials: titanium E40114

Adapter · M18 x 1.5 - M12 x 1 · Insertion depth of the probe of SID, SFD, TN: · 13.5 mm · Housing materials: titanium E40128

Adapter · M18 x 1.5 - M12 x 1 · Insertion depth of the probe of SID, SFD, TN: · 13.5 mm · Housing materials: stainless steel 316L /1.4404

E40101

Temperature sensors

174www.ifm.com

Type Description Orderno.

Adapter · M18 x 1.5 - G ¼ · Insertion depth of the probe of SID, SFD, TN: · 13.5 mm · Housing materials: stainless steel 316L /1.4404

E40099

Adapter · M18 x 1.5 - G ½ · Insertion depth of the probe of SID, SFD, TN: · 21 mm · Housing materials: stainless steel 316L / 1.4404 E40096

Adapter · M18 x 1.5 - ½“ NPT · Insertion depth of the probe of SID, SFD, TN: · 23 mm · Housing materials: stainless steel 316L /1.4404

E40107

G ½ adapter · Clamp · 1-1.5“ · DIN 32676 · for units with G ½ adaptation · Housing materials: stainless steel 316L / 1.4404 E33401

G ½ adapter · Clamp · 2“ · DIN 32676 · for units with G ½ adaptation · Housing materials: stainless steel 316L / 1.4404 E33402

Protective cover · with lead seal option · for pressure sensors type PK · for temperature sensors type TK · for vibration monitor VK ·Housing materials: PP transparent

E30094

Thermowells for temperature sensors

Type Description Orderno.

Welding thermowell · Ø 35 mm · Probe length: 126.5 mm · for type TA343x, TAA431, TAD191 · Housing materials: stainless steel316L / 1.4404

E30403

Thermowell for temperature sensors · G ½ · Probe length: 53 mm · for type TA34xx, TAA431, TAD191 · Housing materials: stainlesssteel 316L / 1.4404

E30393

Thermowell for temperature sensors · Ø 10 mm - G ½ · Probe length: 82 mm · Housing materials: stainless steel 316L / 1.4404 E35010

Thermowell for temperature sensors · Ø 6 mm - G ½ · Probe length: 82 mm · Housing materials: stainless steel 316Ti / 1.4571 E37010

Flange adapters

Type Description Orderno.

Aseptoflex Vario adapter · Clamp · 2“ · ISO 2852 · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housingmaterials: stainless steel 316L / 1.4435

E33202

Aseptoflex Vario adapter · Clamp · 2“ · ISO 2852 · for units with Aseptoflex Vario adapter · Metal to metal seal · Housing materials:stainless steel 316L / 1.4435

E33702

Temperature sensors

175www.ifm.com

Type Description Orderno.

Aseptoflex Vario adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex Vario adapter · Sealing by sealing ring · Housingmaterials: stainless steel 316L / 1.4435

E33201

Aseptoflex Vario adapter · Clamp · 1-1.5“ · ISO 2852 · for units with Aseptoflex Vario adapter · Metal to metal seal · Housingmaterials: stainless steel 316L / 1.4435

E33701

Aseptoflex Vario adapter · Varivent type N · DN40 (1.5“), D = 68 · for units with Aseptoflex Vario adapter · Sealing by sealing ring ·Housing materials: stainless steel 316L / 1.4435

E33222

Aseptoflex Vario adapter · Varivent type N · DN40 (1.5“), D = 68 · for units with Aseptoflex Vario adapter · Metal to metal seal ·Housing materials: stainless steel 316L / 1.4435

E33722

Wiring diagrams

1

4

L

L+1

2

32:4:

2

2

L

L+4

1

3Out 1Out 2

4:2:

3

1

2

3

4

4

L+

L

1

2

5

AS-i+1

3 AS-i

6

PA

PA+2

4

1

3n.c.

n.c.

7

4

1

3

2L+

L

2

1

3

4L+

L

8

Out 1Out 2

4

L

L+2

1

34:2:

4

L

L+2

1

3Out 1Out 2

4:2:

9

TR 8430

L+

Ln.c.Out 4

Out 1Out 2

124

673

Out 353 (n.c.)

1 (n.c.)

4

2

Temperature sensors

176www.ifm.com

Wiring diagrams

10

L+

L

1 BN

2 WH

4 BK

3 BUTR 2432

1

2

3

4

2

B

1

2

3

4

3

1

1

2

3

4

B

B

1: Two-wire sensor, 2: Three-wire sensor, 3: Four-wire sensor, B:link

11

L+

L

1 BN

2 WH

4 BK

3 BU

1

2

3

4

2

B

1

2

3

4

3

1

1

2

3

4

B

B

TR

1: Two-wire sensor, 2: Three-wire sensor, 3: Four-wire sensor, B:link

12

4

1

3

2L+

L

L

IO-Link1

2

3

4

1

2

3

4

1

2

3

4

B

B

TP

1: Two-wire sensor, 2: Four-wire sensor, 3: Operation as 2-wiretemperature transmitter, 4: Operation as 3-wire unit, IO-Linkcommunication possible, B: link

13

2

L+

L

1

L+

L3 BU

4 BK

2 WH

1 BN

2 WH

1 BN

1: 2-wire operation, 2: 3-wire operation

Scale drawings - CAD download: www.ifm.com

1

39

M12 x127

27

96,5

25

8,2

G 41

87

2

48

M12 x127

27

105,

5

35

8,2

-18 NPT41

96

Temperature sensors

177www.ifm.com

Scale drawings - CAD download: www.ifm.com

3

267

M12 x127

27

327

G 21

8

255

4

4514

128

34

8,2

2 3

1

48

94,5

M12

x1

22 4

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4:internal thread M18 x 1.5

5

93

34

16,5

G 21

2 3

1

30

48

60M

12x1

4

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4:connection for temperature sensor

6

93

34

16,5

G 21

2 3

1

30

48

60M

12x1

4

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4:connection for temperature sensor

7

M12x1 17

M12x1

23,5

LED

20 50

2

1: connection for voltage supply and output signals, 2: connectionfor temperature sensor

8

18,5

L

5,95

M12

x1

21,5

401

6,2 13,8

6

1: plug area

9

8

L

10

M12

x1

21,5

18,5

401

1: plug area

10

90

60

22

14

8,2

44

12

M12x1

19

1

1: internal thread M18 x 1.5

Temperature sensors

178www.ifm.com

Scale drawings - CAD download: www.ifm.com

11

1 2

M12

x136

45

4,5 10

50

30

1: Aseptoflex thread, 2: Aseptoflex sealing edge

12

M12

x1

64572

48

13

46

M12

x1

12

745 10

14

M12

x1

42,5 50 6

15

50

12

10742

M12

x1

42,5

16

M12

x1

49,5

14 35

6,5

51

12

17

8,7

1,8

17

4460

8,2

M12x130

27

13,7

117,

7

13,5

G 41

18

5360

8,2

M12x130

27

14,9

127,

9

13,5

G 41

LED

19

G 21

43,8 123

8,2

10

M12

x130

27

18,3

13,7

47,5

180,5

LED

87,5

20

34 123

6

M12

x130

14171

21

G 21

52,8 123

8,2

10

M12

x130

27

18,3

14,7

47,5

190,5

LED

87,5

Temperature sensors

179www.ifm.com

Scale drawings - CAD download: www.ifm.com

22

34 G1

8 10

50,4

87,5140,5

210,5

M12

x1

195,7

23

34 G1

8 10

50,4

3386

156141,2

M12

x1

24

34 G1

8 10

50,4

87,5140,5

210,5

M12

x1

195,7

1

1: Grounding screw

25

34 G1

8 10

50,4

3386

156141,2

M12

x1

1

1: Grounding screw

Temperature sensors

180www.ifm.com

Temperature sensors

181

182

Diagnostic systems

Selection chart Page

Compact vibration diagnostic units with g-monitor to ISO 10816 type VB/VE 185

Accessories VB / VE 185

Vibration monitors for vibration monitoring of machines and plants to ISO 10816 type VK 185

Accessories VK 186

Diagnostic electronics - control cabinet modules for vibration diagnosis type VSE 186

Accessories VSE 186

Vibration sensors for connection to external diagnostic electronics VSE - type VSA 186 - 187

Accessories VSA 187

Scale drawings - CAD download: www.ifm.com 187 - 188

183www.ifm.comwww.ifm.com

Online vibration diagnosis – optimumprice / performance ratio.

Decentralised monitoring of plant and equipment integrated into the machine.

Compact field units and modular control cabinet units.

Digital and analogue alarm outputs.

Standard data interface (OPC).

Diagnostic systems

efector octavis is a vibration monitor which not only detects vibration data, but alsocarries out signal analysis and machine diagnosis directly on the machine. The ma-chine condition is determined and is forwarded to the PLC or to SCADA software. Itfulfils the main requirements for modern machine monitoring: compatibility, modu-larity and transferable configuration.

Compatible and modular

The compatibility with data structures such as the OPC interface makes it possible tointegrate condition data into a higher-level system. With the requirement for modu-larity the user can define the extent of condition monitoring to be implemented –this means the complete range of diagnosis is possible right from the “first unit”.Transferable configuration is attained with application-related parameter sets. Awizard function in the software guides the user through creating, managing andarchiving the monitoring parameters.

Trend memory

All units of the octavis family type VE / VSE feature an internal trend memory whichensures detailed analysis and optimisation of the application even without externaldata recording. The storage intervals are freely selectable. This means that the sto-rage length of the non volatile ring-memory is adjusted to the requirements.

The suitable system for your application:

Standard vibration characteristic values / permanent machine protection: VSE, VE, VK

Internal trend memory / root cause analysis: VSE, VE

Online diagnosis / early damage detection: VSE (VE partly)

Network capability of the system: VSE (VE partly*)

*Profibus DP gateway

Internal trend memory(type VE / VSE) of allmonitored diagnosisfactors can be evalu-ated via PC software.

Easy vibration moni-toring: type VK

provides a com-bination of switching

output and trans-mitter function in

conjunction with thetried and tested

easy-turn concept.

Diagnostic systems

184www.ifm.com

Compact vibration diagnostic units with g-monitor to ISO 10816 type VB/VE

Type Description Draw-ingno.

Orderno.

Vibration diagnostic unit · Spectral analysis / FFT · Envelope-curve FFT · Peak · V eff RMS · Trend analysis · Connection viaM12 x 1 and M8 x 1 connectors · housing: diecast zinc nickel-plated / keypad: polyester

1 VE1001

Vibration diagnostic unit · Spectral analysis / FFT · Envelope-curve FFT · Peak · V eff RMS · Trend analysis · Connection viaM12 x 1 and M8 x 1 connectors · housing: diecast zinc nickel-plated

2 VE1101

Vibration diagnostic unit · ATEX approval · Group II, category 2D · Group II, category 2G · Spectral analysis / FFT ·Envelope-curve FFT · Trend analysis · Cable · housing: diecast zinc

3 VE113A

Accessories VB / VE

Type Description Orderno.

Parameter setting cable for efector octavis · ifm electronic · straight / straight · 3 m · Housing materials: PUR E11572

USB/RS485 adapter cable · ifm electronic · straight / straight E30098

Y connection cable · ifm electronic · 2 way · Free from halogen · 0.25 m · Housing materials: TPU E11664

Vibration monitors for vibration monitoring of machines and plants to ISO 10816 type VK

Type Description Draw-ingno.

Orderno.

Vibration monitor · Connection via M12 connector · Vibration monitor to DIN ISO 10816 · Measuring range Veff: 0...25mm/s · Switching outputs: normally closed and analogue 4...20 mA · PBT / PC / FPM / stainless steel 316L / 1.4404

4 VKV021

Vibration monitor · Connection via M12 connector · Vibration monitor to DIN ISO 10816 · Measuring range Veff: 0...50mm/s · Switching outputs: normally closed and analogue 4...20 mA · PBT / PC / FPM / stainless steel 316L / 1.4404

4 VKV022

Diagnostic systems

185www.ifm.com

Accessories VK

Type Description Orderno.

Protective cover · with lead seal option · for pressure sensors type PK · for temperature sensors type TK · for vibration monitor VK ·Housing materials: PP transparent

E30094

Diagnostic electronics - control cabinet modules for vibration diagnosis type VSE

Type Description Draw-ingno.

Orderno.

Diagnostic electronics for vibration sensors · Ethernet interface · Switching output, Analogue output · Combiconconnection · PA

5 VSE002

Diagnostic electronics for vibration sensors · 4 sensor inputs 0...10 mA · Ethernet interface · Switching output, Analogueoutput · Combicon connection · PA

6 VSE100

Accessories VSE

Type Description Orderno.

Patch cable · Cross-over patch cable · Cable length 5 m E30112

Vibration sensors for connection to external diagnostic electronics VSE - type VSA

Type Description Draw-ingno.

Orderno.

Vibration sensor · for connection to external diagnostic electronics · Connector · housing: stainless steel 316L / 1.4404 7 VSA001

Vibration sensor · for connection to external diagnostic electronics · Cable with connector · housing: stainless steel 316L /1.4404

8 VSA002

Diagnostic systems

186www.ifm.com

Type Description Draw-ingno.

Orderno.

Vibration sensor · for connection to external diagnostic electronics type VSExxx · Cable · housing: stainless steel 316L /1.4404

9 VSA003

Accessories VSA

Type Description Orderno.

conical washer · Ø 8.4 / 15 mm · for efector octavis · Housing materials: stainless steel 316Ti / 1.4571 E30115

Scale drawings - CAD download: www.ifm.com

1

20 M5

M12

x1

46,458,2

14

65,3

36

37,6

5,35

10

4

M8x

1

LED

1

1: Programming buttons

2

M12

x1

46,458,2

14

65,3

36

20 M5

37,6

5

10

4

5,3

M8x

1

3

20 M5

46,462,2

14

65,3

36

37,6

5

10

4

5,3

4

63,7

11

M12 x127

27

73,1

M81

1: tightening torque 15 Nm

Diagnostic systems

187www.ifm.com

Scale drawings - CAD download: www.ifm.com

5

103,4

35,5

25,410

0

1

LEDs

1: Ethernet interface

6

50

114

LEDs

2

1

105

35,5

1: Ethernet interface, 2: Combicon plug with screw terminals (optio-nal)

7

18,5

M8x

1,25

M12

x117

5324

178

1

1: conical angle = 90°

8

13

M16

x1,5

14

2218

5

9

18

11,5

12

1500

5,5

Diagnostic systems

188www.ifm.com

Diagnostic systems

189

190

Bus system AS-interface

Selection chart Page

Controllers, gateways and software 193

AS-i repeaters 193

AS-i power supplies 194

I/O modules for control cabinets 194 - 195

Field modules IP67 195 - 196

Field modules IP69K and accessories 196

Module lower parts 196 - 197

Pneumatic and actuator solutions 197

Safety at Work 197 - 198

AS-i sensors 198

Combicon connectors 198

Flat cable splitters and accessories 199

Accessories Safety at Work 199

Accessories lower parts and addressing units 199 - 200

Accessories pneumatic components 200

Accessories RFID 200

Scale drawings - CAD download: www.ifm.com 201 - 206

191www.ifm.comwww.ifm.com

Manufacturer-independent standard.

Worldwide acceptance as a wiring system.

Communication from the sensor to the controller.

“Safety at Work” for safety-related applications.

Intelligent system solutions for special tasks.

Bus system AS-interface

AS-interface (AS-i = actuator sensor interface) is a manufacturer-independent stan-dard for the connection of actuators and sensors of the first field level. It is the onlywiring system accepted worldwide. With 15 million slaves installed AS-i has beentried and tested as a low-cost feeder for all common fieldbuses for many years.

The product range includes AS-i components for different areas from packaging andconveying via silo applications, machine tools, robotics and automation to the foodindustry and mobile vehicles.

Safe

The sophisticated AS-i technology and the extended diagnostic possibilities providehigh reliability and machine uptime.

“Safety at Work” is the extension of the AS-interface by safety-related components.Safety components up to the highest control category 4 to EN 954-1, SIL 3 to IEC61508 and EN ISO 13849 - 1 / PL e can be connected to AS-i.

Easy

Due to the standardised system, the low wiring complexity and the quick connectiontechnology, AS-i enables simple “Plug & Play”. The reduction of terminals leads toreduced documentation.

Data and energy are jointly transmitted via a two-wire cable. The reverse polarity pro-tected insulation displacement technology helps avoid errors. The modularity and thetree structure smoothly fit to the way the plant is put together.

Cost-optimised

It’s the end result that matters: wiring complexity, documentation and set-up timesare significantly reduced. The decentralisation of the AS-i participants leads tosmaller and less expensive control cabinets. Simple diagnosis and a clear systemdesign result in high machine uptime and avoid downtimes.

With “Safety atWork” AS-i alsosolves safety-related tasks.

Reduced cost:reduced wiring com-

plexity for fasterinstallation and fewer

error sources.

Bus system AS-interface

192www.ifm.com

Controllers, gateways and software

Type Numberof

AS-i masters

Description Draw-ingno.

Orderno.

1SmartLink DP · AS-i gateway / Profibus DP · Full master functions · Graphic display · Housing

materials: aluminium / steel sheet galvanised1 AC1375

2AS-i DP gateway · Full master functions · Graphic display · Profibus DP interface · Housing materials:

aluminium / steel sheet galvanised2 AC1376

2AS-i DP gateway · Full master functions · Graphic display · Profibus DP interface · Housing materials:

aluminium / steel sheet galvanised2 AC1326

1AS-i Ethernet / IP Controller E · Full master functions · Graphic display · Housing materials: aluminium /

steel sheet galvanised3 AC1327

2AS-i Ethernet / IP Controller E · Full master functions · Graphic display · Housing materials: aluminium /

steel sheet galvanised3 AC1337

2AS-i controller E · AS-i controller freely programmable · Full master functions · Graphic display ·

Ethernet programming interface · Housing materials: aluminium / steel sheet galvanised4 AC1354

AS-i repeaters

Type Description Draw-ingno.

Orderno.

AS-i repeater · Extension of the AS-i network by another 100 m · One additional AS-i power supply necessary · Combiconconnection · PA 6.6

– AC2225

Passive AS-i bus termination · Extension of the cable to a maximum of 200 m without additional repeater · Improvementof the signal quality · Monitoring of the supply voltage by means of LEDs

– AC1147

AS-i tuner diagnostic module · Extension of the cable to a maximum of 200 m without additional repeater · Monitoring ofthe message quality · Display of critical states by „traffic light„ LEDs · PBT

5 AC1146

Bus system AS-interface

193www.ifm.com

AS-i power supplies

Type OutputcurrentAS-i [A]

Description Draw-ingno.

Orderno.

0.95 Power supply · AS-i Netzteil 100...240 V DC · Integrated data decoupling · 30 Watt · PC / ABS 6 AC1220

1.9 Power supply · AS-i Netzteil 100...240 V DC · Integrated data decoupling · 60 Watt · PC / ABS 6 AC1221

2.8Power supply · AS-i Netzteil 100...240 V DC · Integrated data decoupling · AlMg3 / steel sheet

galvanised / polycarbonate7 AC1236

4Power supply · AS-i Netzteil 100...240 V DC · Integrated data decoupling · AlMg3 / steel sheet /

polycarbonate7 AC1244

2 x 4Power supply · AS-i dual power supply 115/230 V AC 2 x AS-i · Integrated data decoupling ·

aluminium8 AC1212

8Power supply · AS-i power supply 115/230 V AC · Integrated data decoupling · Jumper to deactivate

the AS-i communication · 240 watts · aluminium / steel sheet galvanised9 AC1218

I/O modules for control cabinets

Type Inputs /outputs

Description Draw-ingno.

Orderno.

4 inputsActive AS-i module · String mounting possible · Addressing socket · Input supply from

external PELV voltage source · Version 2.1 with extended addressing mode · Digital inputs· Combicon connection · PA

10 AC2254

4 outputsActive AS-i module · String mounting possible · Addressing socket · Version 2.1 · Digital

outputs · Combicon connection · PA10 AC2252

4 inputs / 3 outputsActive AS-i module · String mounting possible · Addressing socket · Version 2.1 withextended addressing mode · Digital inputs and outputs · Combicon connection · PA

10 AC2264

4 inputs / 4 outputsActive AS-i module · String mounting possible · Addressing socket · Version 2.1 · Digital

inputs and outputs · Combicon connection · PA10 AC2251

4 inputs / 4 outputs;bidirectional

Active AS-i module · String mounting possible · Addressing socket · External sensor supplyPELV · Version 2.1 · Digital inputs and outputs · Combicon connection · PA

10 AC2257

4 inputs 4...20 mAActive AS-i module · AS-i profile S-7.3 · 4 analogue inputs 4...20 mA · For the connectionof 2-wire, 3-wire or 4-wire sensors · Combicon connector for sensor connection · PA 6.6

10 AC2216

2 inputs / 1 LED output Active AS-i module · Only suited for mechanical contacts 11 AC2729

Bus system AS-interface

194www.ifm.com

Type Inputs /outputs

Description Draw-ingno.

Orderno.

4 inputs / 3 outputs Active AS-i module · AS-i version 2.1 with extended addressing mode 12 AC2730

Field modules IP67

Type Inputs /outputs

Description Draw-ingno.

Orderno.

4 inputsActive ClassicLine module · Version 2.11 and 3.0 with extended addressing mode ·Addressing socket · Three orientations of the flat cable are possible · Digital inputs ·

Sockets M12 x 1 · PA13 AC5215

4 outputsActive ClassicLine module · Addressing socket · Three orientations of the flat cable are

possible · Digital outputs · Sockets M12 x 1 · PA13 AC5208

2 outputs / 2 inputsActive ClassicLine module · Version 2.11 and 3.0 with extended addressing mode ·

Addressing socket · Three orientations of the flat cable are possible · Digital outputs andinputs · Sockets M12 x 1 · PA

13 AC5214

4 inputs / 3 outputs;bidirectional

Active ClassicLine module · Addressing socket · Three orientations of the flat cable arepossible · Version 2.11 and 3.0 with extended addressing mode · Digital inputs and

outputs · Sockets M12 x 1 · PA14 AC5204

4 inputs / 4 outputs;bidirectional

Active ClassicLine module · Only for operation with AS-i masters with the profile M4 ·Addressing socket · Three orientations of the flat cable are possible · Version 3.0 with

extended addressing mode · Digital inputs and outputs · Sockets M12 x 1 · PA14 AC5235

2 pushbuttons / 2 LED displaysActive module upper parts AS-i illuminated pushbutton module · Power supply via AS-i

cable · Colour inserts changeable · PBT15 AC2086

2 inputs 4...20 mAActive ClassicLine module · 2 analogue inputs 4...20 mA · For the connection of 2-wire

and 3-wire sensors · Addressing socket · Three orientations of the flat cable are possible ·PA

13 AC5222

4 inputsActive CompactLine module · Version 2.1 with extended addressing mode · IR addressing

possible · Digital inputs · Sockets M12 x 1 · PUR16 AC2457

4 inputsActive CompactLine module · IR addressing possible · high-grade stainless steel · Digital

inputs · Sockets M12 x 1 · PA / stainless steel 316L / 1.440416 AC2451

4 outputsActive CompactLine module · IR addressing possible · Digital outputs · Sockets M12 x 1 ·

PA16 AC2417

2 inputs / 2 outputsActive CompactLine module · IR addressing possible · Digital inputs and outputs · Sockets

M12 x 1 · PA16 AC2411

Bus system AS-interface

195www.ifm.com

Type Inputs /outputs

Description Draw-ingno.

Orderno.

4 inputs / 4 outputs;bidirectional

Active CompactLine module · IR addressing possible · Digital inputs and outputs · SocketsM12 x 1 · PA

17 AC2412

4 inputs / 4 outputs;bidirectional

Active CompactLine module · IR addressing possible · Digital inputs and outputs · SocketsM12 x 1 · PA / stainless steel 316L / 1.4404

17 AC2452

Field modules IP69K and accessories

Type Inputs /outputs

Description Draw-ingno.

Orderno.

4 inputs / 3 outputsActive ProcessLine module · Version 2.1 with extended addressing mode · Protection

rating IP 69K · high-grade stainless steel · Digital inputs and outputs · Sockets M12 x 1 ·high-grade stainless steel / Makrolon / O-ring: EPDM

18 AC2904

8 digital inputs (2 Slaves)Active ProcessLine module · Version 2.1 with extended addressing mode · Protection

rating IP 69K · high-grade stainless steel · Digital inputs · Sockets M12 x 1 · high-gradestainless steel / Makrolon / O-ring: EPDM

19 AC2910

8-way splitter boxPassive splitter box AS-i ProcessLine · Protection rating IP 69K · high-grade stainless steel ·

AS-i and AUX splitter box for the connection of intelligent sensors/actuators · SocketsM12 x 1 · high-grade stainless steel / Makrolon

20 AC2900

4 inputs 4...20 mAActive AS-i module · 4 analogue inputs 4...20 mA · For the connection of 2-wire and 3-wire sensors · Threaded bush: stainless steel 316L / 1.4404 / Makrolon / O-ring: EPDM

21 AC2916

AS-i / 24 VFC splitter · V4A · AS-i voltage and external auxiliary voltage via the M12 socket · Metal

parts: stainless steel 316L / 1.4404 / Blanks: FPM / O-ring: EPDM– E70354

AS-iFC splitter · AS-i voltage via M12 socket · Metal parts: stainless steel 316L / 1.4404 / O-

ring: EPDM / socket: PP GF30 / blade seal: TPE– E70454

Module lower parts

Type Inputs /outputs

Description Draw-ingno.

Orderno.

FC coupling moduleModule lower part flat cable · AS-i interface to module upper part · Quick mounting

technology for AS-i flat cable · PBT22 AC5000

FC-E coupling module withexternal power supply

FC-E coupling module · AS-i interface to module upper part · Quick mounting technologyfor AS-i flat cable · PBT

22 AC5003

FC coupling moduleModule lower part flat cable · stainless steel · AS-i interface to module upper part · Quick

mounting technology for AS-i flat cable · PBT / stainless steel22 AC5014

FC-E coupling module withexternal power supply

FC-E coupling module · stainless steel · AS-i interface to module upper part · Quickmounting technology for AS-i flat cable · PBT / stainless steel

22 AC5015

Bus system AS-interface

196www.ifm.com

Type Inputs /outputs

Description Draw-ingno.

Orderno.

SC coupling module Module lower part set · AS-i interface to module upper part · Screw terminal · PBT 23 AC5031

Pneumatic and actuator solutions

Type Inputs /outputs

Description Draw-ingno.

Orderno.

4 inputs / 2 outputs; AirBoxsupply via AS-i

AS-i AirBox · 2 x 3/2-way slide valves free from overlapping · Three orientations of the flatcable are possible · AS-i flat cable connection · Version 2.11 and 3.0 with extended

addressing mode · Addressing socket · PA / POM24 AC5228

4 inputs / 1 output ; AirBoxsupply via AS-i

AS-i AirBox · 5/2-way slide valve free from overlapping · Three orientations of the flatcable are possible · AS-i flat cable connection · Version 2.11 and 3.0 with extended

addressing mode · Addressing socket · PA / POM25 AC5246

Safety at Work

Type Description Draw-ingno.

Orderno.

AS-i safety monitor · Basic version · 2-channel · Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1PL e · Configuration and setup by configuration software ASIMON · Screw terminal · polyamide black

26 AC002S

AS-i safety monitor · Extended functionality · 2-channel · Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO13849 - 1 PL e · Configuration and setup by configuration software ASIMON · Screw terminal

26 AC004S

AS-i safety monitor · Extended functionality and integrated safe slave for triggering a safe AS-i output · 1-channel ·Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e · Configuration and setup by configuration

software ASIMON V3.0 · Screw terminal · polyamide black27 AC031S

AS-i safety monitor · Extended functionality and integrated safe slave for triggering a safe AS-i output · 2-channel ·Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e · Configuration and setup by configuration

software ASIMON V3.0 · Screw terminal27 AC032S

Safe active AS-i module · Control category 4 according to EN954-1 and IEC 61508 / SIL 3 · For the connection ofmechanical contacts · Combicon connection

28 AC009S

Safe active AS-i output module · Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e · for thesafe triggering of actuators · Combicon connection

29 AC030S

Safe active AS-i module · Connection via M12x1 sockets or cage clamps · Control category 4 according to EN954-1 andIEC 61508 / SIL 3 · Version 2.1 · For connection of an electro-sensitive protective equipment (ESPE) type 4 to EN 61496-1 ·

AS-i interface to FC-E lower parts30 AC007S

Safe AS-i input module · IR addressing possible · AS-i version 2.1 · Performance Level e to EN ISO 13849-1 for theconnection of mechanical contacts · Sockets M12 x 1 · PBT

31 AC005S

Bus system AS-interface

197www.ifm.com

Type Description Draw-ingno.

Orderno.

Illuminated E-STOP with integrated AS-i connection · Connector M12 x 1 · AS-i interface via AS-i flat cable IP 67 · fool-proof E-STOP to EN ISO 13850 / EN 418 · Pull to reset

32 AC010S

safe AS-i e-stop operating unit with integrated AS-i connection · AS-i interface via M12 x 1 connector · fool-proof E-STOPto EN ISO 13850 / EN 418 · Pull to reset · interchangeable button inserts

33 AC012S

AS-i safety PCB · Connection of mechanical contact and LED components · Certification according to EN 954-1 / category4 and IEC 61508 / SIL 3

11 AC015S

AS-i sensors

Type Description Draw-ingno.

Orderno.

Read/write head · DTSLF AARWASUS01 · with integrated AS-i slave profile 7.4 · M12 connector · PA 34 DTA100

Read/write head · DTSLF DCRWASUS01 · with integrated AS-i slave profile 7.4 · M12 connector · housing: PPE / Metalparts: diecast zinc / brass nickel-plated

35 DTA300

Combicon connectors

Type Description Orderno.

Combicon connector · with screw terminals 4-pole · Housing materials: current carrying parts: copper alloy tin-plated · Pack quantity:6

E70230

Combicon connector · with screw terminals 4-pole · Housing materials: current carrying parts: copper alloy tin-plated · Pack quantity:100

E70231

Bus system AS-interface

198www.ifm.com

Flat cable splitters and accessories

Type Description Orderno.

FC splitter · AS-i voltage via M12 socket · Housing materials: Metal parts: stainless steel 316L / 1.4404 / O-ring: EPDM / socket: PPGF30 / blade seal: TPE

E70454

FC splitter · V4A · AS-i voltage and external auxiliary voltage via the M12 socket · Housing materials: Metal parts: stainless steel 316L/ 1.4404 / Blanks: FPM / O-ring: EPDM

E70354

FC insulation displacement connector · Socket M12 - AS-i flat cable · Housing materials: PA E70096

Protective cap · M12 · for M12 sockets of ClassicLine modules, CompactLine modules and AirBoxes · Housing materials: PA black E73004

Protective cap · M12 · for M12 socket to cover the unused inputs and outputs on the module; for unused inputs of splitter boxes ·for ProcessLine modules · Housing materials: PVC

E70297

Accessories Safety at Work

Type Description Orderno.

Connection cable PC / AS-i safety monitor · Parameter setting cable PC / AS-i safety monitor · Western connector RJ 45 8 poles / D-Sub socket 9 poles · 2.5 m

E7001S

bridging plug for safety modules · Housing materials: PUR E7005S

Accessories lower parts and addressing units

Type Description Orderno.

AS-i addressing unit · AS-i version 2.1 with extended addressing mode AC1144

Addressing cable · for AS-i slaves · 1.6 m E70213

Programming cable for controller E · Western connector RJ11 6 poles / D-Sub socket 9 poles · 1.55 m E70320

Module lower part set · Screw terminal · Housing materials: PBT AC5031

Bus system AS-interface

199www.ifm.com

Type Description Orderno.

Use of the lower part as branching box · Housing materials: plastics AC3000

AS-i flat cable · reverse polarity protection due to special shape · for use in isolation displacement connector technology for FC lowerparts and compact modules

AC4000

AS-i flat cable · reverse polarity protection due to special shape · for use in isolation displacement connector technology for FC lowerparts and compact modules

AC4002

AS-i flat cable · for the food industry · reverse polarity protection due to special shape · 100 m AC4007

AS-i flat cable · for the food industry · reverse polarity protection due to special shape · 100 m AC4008

JOKARI flat cable stripping tool E70062

Flat cable seal · Housing materials: ULTRAMID / sealing: NBR · Pack quantity: 10 E70413

Accessories pneumatic components

Type Description Orderno.

Silencer · Housing materials: connection piece: PP / filter: PE E75232

Accessories RFID

Type Description Orderno.

ID tag · ID-TAG/TRIANGEL HOUSING/01 · with ID tag E80301 · Housing materials: PBT orange (RAL 2003) / PA black (RAL 9005) E80302

ID tag · ID-TAG/D20x2.15/01 · Ø 20 x 2.15 mm · Housing materials: polycarbonate black E80317

ID tag · ID-TAG/ISO-Card/01 · 54 x 86 x 1 mm · Housing materials: PVC white E80320

Bus system AS-interface

200www.ifm.com

Scale drawings - CAD download: www.ifm.com

1

85

124

138

LED

62

4

6857

2

4

10797

86

124

131

LED

62

LED

3

4

10797

86

124

131

LED

62

LED

4

86

124

131

LED

62

4

10797

5

44

83

90

M12 x1

LED

1 2

1: tune button, 2: mode selector

6

45 100

90

LED

Bus system AS-interface

201www.ifm.com

Scale drawings - CAD download: www.ifm.com

7

136144

136

50

129

LED

8

113118,5

134

120

9

4

10796

91

124

131

Jumper

LED

10

105

35,5

25

114

LEDs

1

1: Addressing socket

11

921 U U UU

44

32

9 10 10

12

88

44

13

14

Bus system AS-interface

202www.ifm.com

Scale drawings - CAD download: www.ifm.com

15

4530

80

16

17 24

118

FE

60

107

39

4,5

36

LED M12x1

17

60

107

39

4,5

36

M12x1LEDFE

152

17 24

18

M12

x1

43,6

80137,3

M12 x1 LED

19

137,3

M12 x1 LED

M12

x1

43,6

80

20

M12

x1

43,6

80137,3

M12 x1

21

137,3

M12 x1

1

M12

x1

43,6

80

Bus system AS-interface

203www.ifm.com

Scale drawings - CAD download: www.ifm.com

22

80

206

35

66

31

9,65,3

45

7 7

77

23

8082,5

336

35

66

45

9,65,3

31

7 7

77

24

2

4

0

1

0

1

9110

8

85

1 50

40

25

1 50

40

2

4

0

1

9110

8

85

26

120

35,5

45

104

LED

27

45

105,

9

120

35,5

102

82,6

91,2

Bus system AS-interface

204www.ifm.com

Scale drawings - CAD download: www.ifm.com

28

105

35,5

2510

8

LEDs

1

1: Addressing socket

29

2

105

35,5

25

108

1

1: Addressing socket, 2: LED

30

45,5

49,4

8011

1

31

25

80

45

LEDM12x1

32

58,5

66,5

UU

UU

93,5

5610

5

M12

x1

72

80

33

5610

5

207

12072

M12

x1

80

34

5

2

41

4,517

56

17

4,25,5

M12 x1

24

5570

LED

2

1

53,5

1: integrated antenna , 2: tag positioning mark (middle of the anten-na)

Bus system AS-interface

205www.ifm.com

Scale drawings - CAD download: www.ifm.com

35

92

80

40

7,565

65

5,59,3

M12

x1

112

40

LED171

20

1: mounting on DIN rail

Bus system AS-interface

206www.ifm.com

Bus system AS-interface

207

208

Multicode reading systems

Selection chart Page

Multicode reader 211

Accessories 211

Scale drawings - CAD download: www.ifm.com 211

209www.ifm.comwww.ifm.com

Orientation-independent identification of 1D and 2D codes.

Very small housing for flexible use.

Simple, menu-guided parameter setting.

Integrated lighting.

High reading reliability even with soiled / damaged codes.

Multicode reader

The ECC200 Data Matrix code is becoming more and more popular throughoutindustry alongside familiar barcodes. In this code lots of information can be stored ina very small space and read using the compact multicode reader. The industriallycompatible mounting and wiring technology as well as the standardised processinterfaces RS-232, Ethernet TCP/IP and EtherNet/IP enable easy and quick integrationinto the industrial control technology. Applications can be found in many differentindustrial areas: from the product tracking and production control to product identi-fication.

Orientation-independent reading

Independent of the orientation and the number of codes, the high-performancealgorithms automatically decode 1D or 2D codes. The optimisation parameters of thecodes and functions of the multicode reader undergo continuous development andare made available as upgrades.

Code comparison in the sensor

Complex application programming is no longer necessary due to adjustable, selec-tive code identification and comparison in the sensor. This allows a defined numberof characters within a code to be checked and signalled via the switching output ifthey match.

Reliable identification of 1D and 2D codes

In addition to the automatic exposure setting, manual adjustment is also possible. Sooptimum results are achieved even with highly reflective metal surfaces. For evalua-tion of the code quality parameter, ISO / IEC 15415 or 16022 can be used.

The Data Matrix code

The Data Matrix code is a two-dimensional code containing much more informationwith the same structure size than codes such as bar codes or stacked codes. Severalthousand characters can be stored in one code.

An important feature of the Data Matrix code is the high reading reliability. Ifthe code is soiled or damaged, the intelligent system can completely recomposethe information from different segments again. The Data Matrix code can bestructured differently and is variable in shape and size. The size can cover 1 x 1 mmto 100 x 100 mm.

Lose no time: themulticode reader canbe configured in afew minutes and isthen ready for use.Only five guided stepsare necessary for themulticode reader tobe ready for opera-tion. Whether printed

on paper, graved bylaser or dot-peened

on metal: reliable de-tection of the code,independent of thesensor orientation.

Multicode reading systems

210www.ifm.com

Multicode reader

Type Dimensions

[mm]

Max.field of

view size[mm]

Typeof light

LED

Motion speedint. / ext. lighting

[m/s]

Processinterface

Draw-ingno.

Orderno.

M12 plug, 8 poles M12 socket, 4 poles

60 x 42 x 53.5 68 x 50 red light 3 / 5Ethernet TCP/IP,

EtherNet/IP, RS-2321 O2I100

Accessories

Type Description Orderno.

Operating software · O2I · for multicode reader · Create and manage application-specific configurations Monitor mode for set-upand service Service reports for statistical evaluations

E2I200

Plastic protective pane for the food industry · O2D / O2I · Housing materials: housing: diecast zinc black / lens: PMMA E21166

Mounting set · O2D, O2M, O2I · Clamp mounting · rod mounting Ø 12 mm · Housing materials: fixture: stainless steel / clamp:stainless steel

E2D110

mounting rod · Ø 14 / M12 · Length: 130 mm · straight · Housing materials: stainless steel 316Ti / 1.4571 E20939

mounting rod · Ø 14 / M12 · Length: 200 mm · angled · Housing materials: stainless steel 316Ti / 1.4571 E20941

Scale drawings - CAD download: www.ifm.com

1

M12x1

2

19

M12x1

53,5

4,3

20,5

44

19,733

1

45

24,5

42

57

8060

21

9,57

3

1: display, 2: Focus setting, 3: Centre of the lens axes

Multicode reading systems

211www.ifm.com

212

RF-identification systems

Selection chart Page

RFID systems 215

Accessories 215

Wiring diagrams 215

Scale drawings - CAD download: www.ifm.com 216

213www.ifm.comwww.ifm.com

RFID write and read heads and aselection of tags.

Industrial ident system using the125 kHz range.

Up to 31 compact read / write headsper evaluation module.

Read or write up to 15 bits within20 milliseconds.

Data interface to high end systems;Profibus, DeviceNet, ethernet and others.

RF-identification systems

The constant increase of the degree of automation in modern production plants isincreasingly supported by identification systems. Their tasks include for example thecontrol or release of production steps or the assignment of information about eachproduct.

The RF identification system (Radio Frequency Identification System) from ifm elec-tronic is a compact and easy alternative for applications in which for example opticalidentification is not possible due to the ambient conditions. It is also the first RF iden-tification system for AS-interface worldwide. It allows reading and writing of codecarriers (ID tags), benefiting from the advantages of AS-interface.

It can be integrated into existing AS-I networks without problem and is immediatelyready for operation. For reading, the RF identification system uses the AS-i analogueprotocol 7.4 for data transfer. Special software modules are not required. Up to 31read/write heads can be connected to one AS-i master.

The read/write head stores transmission errors which can be retrieved for a targetedfault analysis. Antenna, electronics and AS-interface are integrated in a compacthousing. The voltage is supplied via the AS-i network via a rotatable M12 connector.No additional operating voltage required.

The ID TAG (transponder) provides flexible mounting options for workpiece carriers,tanks, etc., ...

Operating principle

The RFID system from ifm electronic generates a 125 kHz electromagnetic field forreading and writing of data. The electromagnetic field emitted by the antenna indu-ces voltage in the passive ID tag (transformer principle). This activates the ID tag(transponder) which returns its code. Processing of the code and transmission to theAS-interface are carried out in the read / write head. Advantages: reliable data trans-mission in dynamic reading processes and ID tags for each application.

The read / write headsexchange data withthe passive ID tags ata maximum distanceof 20 mm. The ID tagprovides flexibility fordifferent types ofmounting.

The ID tag is mountedto tanks or workpiece

carriers – in the tagfixture or alternatively

by direct mountingusing an M5 grub

screw.

RF-identification systems

214www.ifm.com

RFID systems

Type Dimensions

[mm]

Travel speedread / write

[m/s]

Processinterface

Wiringdiagram

no.

Draw-ingno.

Orderno.

M12 connector

55 x 24 x 41 read: ≤ 0.5 (distance to the ID tag 15 mm) write: only static AS-i 1 1 DTA100

92 x 80 x 40 read: ≤ 0.5 (distance to the ID tag 40 mm) write: only static AS-i 1 2 DTA300

Accessories

Type Description Orderno.

ID tag · ID-TAG/TRIANGEL HOUSING/01 · with ID tag E80301 · Housing materials: PBT orange (RAL 2003) / PA black (RAL 9005) E80302

ID tag · ID-TAG/D20x2.15/01 · Ø 20 x 2.15 mm · Housing materials: polycarbonate black E80317

ID tag · ID-TAG/ISO-Card/01 · 54 x 86 x 1 mm · Housing materials: PVC white E80320

Dovetail clamp · for type DTS, O4, O5 · Housing materials: AlMgSi0.5 E21088

Wiring diagrams

1

AS-i+1

3 AS-i

RF-identification systems

215www.ifm.com

Scale drawings - CAD download: www.ifm.com

15

2

41

4,517

56

17

4,25,5

M12 x1

24

5570

LED

2

1

53,5

1: integrated antenna , 2: tag positioning mark (middle of the anten-na)

2

92

80

40

7,565

65

5,59,3

M12

x1

112

40

LED171

20

1: mounting on DIN rail

RF-identification systems

216www.ifm.com

RF-identification systems

217

218

Power supplies

Selection chart Page

Switched-mode power supplies 221

Scale drawings - CAD download: www.ifm.com 221 - 222

219www.ifm.comwww.ifm.com

Range of regulated 24 V DC switchedmode power supplies.

Both 1-ph and 3-ph primaryside available.

From 1 amp up to 40 amp load.

Robust metal housing, easy and safe DIN rail mounting.

Robust metal housings with 35 mmrail mounting.

Power supplies

They may be unglamorous and unobtrusive, but without them it would not be pos-sible to operate an electronic system. Power supplies are essential. ifm offers low-cost transformer power supplies but also powerful switched-mode power suppliesfor different applications.

Transformer power supplies

Transformer power supplies provide a low voltage, normally 24 V DC. A transformeraccording to DIN 0551 ensures a safe electrical separation from mains voltage andlow voltage. The output voltage can be regulated (± 5 %) or smoothed by means ofcapacitors. The different designs and output powers allow adaptation to diverse op-erating conditions.

Switched-mode power supplies

Primary switched-mode power supplies are a compact and economical solution tosupply sensors and actuators. As opposed to conventional transformer power sup-plies with regulated output voltage they need no heavy transformers so that thereare fewer iron and copper losses. They are therefore distinguished by a very highdegree of efficiency of up to 92 %. Due to the operating principle by means of highfrequency transformers switched-mode power supplies are much smaller and lighterthan transformer power supplies with identical power. Nevertheless they guaranteean electrical separation. Furthermore, they offer a wide input voltage range as stan-dard for worldwide use.

Power reserves

Mains fluctuations up to ± 15 % and mains interference are compensated for. Evenmains voltage dips of a few milliseconds are compensated for, the output voltage iscompletely maintained. An active inrush current limitation reduces the inrush currentby means of a fixed resistor which is bridged after start up. The outputs are pro-tected against short circuits and overload. Special output characteristics allow acurrent which can be up to 1.7 higher than the nominal current without switch-offwith the voltage being reduced at the same time. The dimensioning of the compo-nents allows a 20 to 25 % higher output current for a short time. This power reserveis provided by all power supplies as from 2.5 A for a period of one minute. At an op-erating temperature of up to 45 °C this power is available continuously.

Suitable for theapplication: ifmprovides powersupplies in differentpower classes.

Power supplies

220www.ifm.com

Switched-mode power supplies

Type Current

[A]

Output voltage

[V]

Nominal voltage

[V]

Efficiencytyp.[%]

Draw-ingno.

Orderno.

10 24...28 DC (±2%) 115 / 230 AC 90 1 DN2013

20 24...28 DC (±2%) 230 AC 91 2 DN2014

5 24...28 DC (±2%) 3 x 400...500 AC 89 3 DN2032

10 24...28 DC (±2%) 3 x 400...500 AC 90 4 DN2033

30 24...28 DC (±2%) 3 x 400...500 AC 93 5 DN2036

40 24...28 DC (±2%) 3 x 400...500 AC 92.5 6 DN2035

1.25 24...28 – 84 7 DN1030

2.5 24...28 – 88 7 DN1031

2.5 24...28 – 87.1 8 DN3011

5 24...28 – 88.9 8 DN3012

Scale drawings - CAD download: www.ifm.com

1

89

4

107

124

120

131

LED

2

124

220

131

LED

227

89

4

107

Power supplies

221www.ifm.com

Scale drawings - CAD download: www.ifm.com

3

124

73

LED

131

4 122

103

4

4

121110

90

124

131

3

2

1

6

5

4

1: LED red, 2: reset push button, 3: jumper „overload performance“,4: jumper „single/parallel operation“, 5: with pot., 6: LED green

5

89

4

107

124

240

131

LED

247

6

89

4

107

124

275

131

282

LED

7

45 100

90

LED

1: with pot.

8

136144

136

50

129

1

LEDs

1: with pot.

Power supplies

222www.ifm.com

Power supplies

223

224

Connection technology

Selection chart Page

Sockets for industrial applications 227

Sockets for industrial applications 227 - 228

Cable plugs for industrial applications 228

Connectors for oils and coolants 229

Connectors for oils and coolants 229

Connectors for electromagnetric fields 229

Connectors for hygienic and wet areas 230 - 231

Connectors for hazardous areas 231

Scale drawings - CAD download: www.ifm.com 231 - 234

225www.ifm.comwww.ifm.com

Complete product range: sockets, plugs, jumper cables, splitter boxes.

Various cable materials for different applications.

High-quality materials for maximum reliability.

“ecolink” series with innovative quality features.

Integrated LEDs for easy diagnosis.

Connection technology

With a wide variety of different sensor designs ifm electronic offers a wide range ofhigh quality connectors. The choice of types covers common M8, M12, M18 typesthrough to valve plugs. The “ecolink” connectors (order no. EVxxxx) offer additionalquality features.

ecolink - a new dimension in connection technology

Due to the special installation of a mechanical end stop the O-ring is always correct-ly compressed and so permanently maintains its sealing function. The connectorremains securely positioned on the unit even in case of extreme vibration andimpacts. Novel design and a transparent black housing ensure that even in brightlighting conditions the LEDs are more clearly visible than with the clear transparentversions.

For industrial applications:

High-quality materials suited to the requirements in industrial environments. Largelyresistant to oils and greases.

For hygienic and wet areas:

PVC housing and cable, gold-plated contacts and high-grade stainless steel nuts arethe optimum choice for long life.

For oils and coolants:

With PUR housings, cable with full PUR sheaths, Viton seals and gold contacts, theseproducts set new standards for the harsh operating conditions of the machine toolindustry.

For hazardous areas

Connection technology for ATEX categories 2D, 3D and 3G. With the EC typeexamination certificate for components from DEKRA EXAM the connection technol-ogy meets the strictest requirements.

For welding applications

Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated couplingnuts prevent weld spatter sticking. The cables are also suited for drag chains and tor-sional movements.

For sensors in robust applications:

The saw tooth contoured vibration protection secures against strong shocks andvibrations. The high protection rating, wide temperature range and high-qualityhousing materials (high-grade stainless steel, TPU) ensure permanent safe connectionin harsh environments.

Black, transparenthousing for optimumLED visibility.

Maximum operationalreliability due to the

new vibration protec-tion with end stop.

Connection technology

226www.ifm.com

Sockets for industrial applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M8, 3-pole, 3-wire, straight

5 m blackPUR cable 3 x 0.25 mm2, Ø 3.7 mm

TPU /brass

50 AC60 DC

-25...90IP67 / IP68 /

IP69K– 1 EVC142

10 m blackPUR cable 3 x 0.25 mm2, Ø 3.7 mm

TPU /brass

50 AC60 DC

-25...90IP67 / IP68 /

IP69K– 1 EVC143

Socket M8, 3-pole, 3-wire, angled

5 m blackPUR cable 3 x 0.25 mm2, Ø 3.7 mm

TPU /brass

50 AC60 DC

-25...90IP67 / IP68 /

IP69K– 2 EVC145

10 m blackPUR cable 3 x 0.25 mm2, Ø 3.7 mm

TPU /brass

50 AC60 DC

-25...90IP67 / IP68 /

IP69K– 2 EVC146

Socket M8, 3-pole, 3-wire, angled, LED, PNP

5 m blackPUR cable 3 x 0.25 mm2, Ø 3.7 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /yellow

3 EVC148

10 m blackPUR cable 3 x 0.25 mm2, Ø 3.7 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /yellow

3 EVC149

Socket M8, 4-pole, 4-wire, straight

5 m blackPUR cable 4 x 0.25 mm2, Ø 3.7 mm

TPU /brass

50 AC60 DC

-25...90IP67 / IP68 /

IP69K– 4 EVC151

10 m blackPUR cable 4 x 0.25 mm2, Ø 3.7 mm

TPU /brass

50 AC60 DC

-25...90IP67 / IP68 /

IP69K– 4 EVC152

Socket M8, 4-pole, 3-wire, angled

5 m blackPUR cable 4 x 0.25 mm2, Ø 3.7 mm

TPU /brass

50 AC60 DC

-25...90IP67 / IP68 /

IP69K– 5 EVC154

10 m blackPUR cable 4 x 0.25 mm2, Ø 3.7 mm

TPU /brass

50 AC60 DC

-25...90IP67 / IP68 /

IP69K– 5 EVC155

Sockets for industrial applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4-pole, angled

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

250 AC/DC -25...100 IP68 – 6 E11509

Socket M12, 4-pole, straight

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

250 AC/DC -25...100 IP68 – 7 E11508

Socket M12, 4/5-pole, 4-wire, angled

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVC005

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVC006

Socket M12, 4/5-pole, 4-wire, straight

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 9 EVC002

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 9 EVC003

Connection technology

227www.ifm.com

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

socket M12, 8-pole, 7-wire + screen

2 m orangePUR cable 7 x 0.25 mm2 + screen

TPU /brass

30 AC36 DC

-25...90 IP67 – 10 E20738

socket M12, 8-pole, 8-wire, for temperature sensors TR 8...

5 m blackPUR cable 8 x 0.25 mm2, Ø 6.2 mm

PUR /brass

30 AC36 DC

-25...80 IP68 – 11 E11232

Socket M16, 14-pole, 12-wire, angled

5 m blackPUR cable

10 x 0.25 mm2 + 2 x0.34 mm2, Ø 7.5 mm

PUR /brass

30 DC -25...90 IP67 – 12 E11697

socket 1/2“, 2-pole + PE, 3-wire

5 m yellowPVC cable 3 x 0.34 mm2, Ø 5.2 mm

TPU /brass

250 AC300 DC

-25...90 IP67 – 13 E10200

5 m yellowPVC cable

3 x AWG22, Ø 5.2 mmTPU /brass

250 AC300 DC

-25...90 IP67 – 14 E10191

socket 1/2“, 5-pole, 4-wire

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.7 mm

TPU /brass

300 AC -25...90 IP67 – 15 E11248

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.7 mm

TPU /brass

300 AC -25...90 IP67 – 15 E11249

Cable plugs for industrial applications

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Plug M12, 4-pole, angled

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

250 AC/DC -25...100 IP68 – 16 E11505

Plug M12, 4-pole, straight

wirable ...0.75 mm2 (Ø 4...6 mm)PA /brass

250 AC/DC -25...100 IP68 – 17 E11504

Plug M12, 5-pole, 5-wire, straight

2 m blackPUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

30 AC36 DC

-25...90IP67 / IP68 /

IP69K– 18 EVC094

Connection technology

228www.ifm.com

Connectors for oils and coolants

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4/5-pole, 4-wire, angled

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVC005

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVC006

Socket M12, 4/5-pole, 4-wire, straight

5 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 9 EVC002

10 m blackPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 9 EVC003

Connectors for oils and coolants

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

M12 splitter box for 1 signal

10 m blackPUR cable

4 x 0.34 mm2 + 3 x 1 mm2,Ø 7.5 mm

PA 10...30 DC -25...80 IP67green /

4 x yellow19 EBC027

10 m blackPUR cable

6 x 0.34 mm2 + 3 x 1 mm2,Ø 7.8 mm

PA 10...30 DC -25...80 IP67green /

6 x yellow20 EBC031

10 m blackPUR cable

8 x 0.34 mm2 + 3 x0.75 mm2, Ø 8.2 mm

PA 10...30 DC -25...80 IP67green /

8 x yellow21 EBC035

Connectors for electromagnetric fields

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4-pole, 4-wire, angled

5 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVW005

10 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 8 EVW006

Socket M12, 4-pole, 4-wire, straight

5 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 9 EVW002

10 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

250 AC300 DC

-25...90IP67 / IP68 /

IP69K– 9 EVW003

Socket M12, 4-pole, 4-wire, angled, LED, PNP

5 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow22 EVW008

10 m greyPUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

10...36 DC -25...90IP67 / IP68 /

IP69Kgreen /

2 x yellow22 EVW009

Connection technology

229www.ifm.com

Connectors for hygienic and wet areas

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M8, 3-pole, 3-wire, angled

5 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 23 E11498

10 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 23 E11499

Socket M8, 3-pole, 3-wire, straight

5 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 24 E11495

10 m orangePVC cable 3 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...85 IP68 – 24 E11496

Socket M8, 4-pole, 4-wire, angled

5 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 25 E11220

10 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 25 E11221

Socket M8, 4-pole, 4-wire, straight

5 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 26 E11223

10 m orangePVC cable 4 x 0.25 mm2, Ø 5 mm

PVC / st. steel316L / 1.4404

60 AC75 DC

-25...90 IP68 – 26 E11224

Socket M12, 4-pole, 4-wire, angled

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 27 EVT004

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 27 EVT005

Socket M12, 4-pole, 4-wire, straight

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 28 EVT001

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 28 EVT002

Socket M12, 4-pole, 4-wire, angled, LED, PNP

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow29 EVT007

10 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

10...36 DC -25...100IP67 / IP68 /

IP69Kgreen /

2 x yellow29 EVT008

Jumper M12, 4-pole, 4-wire, straight / straight

0.3 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 30 EVT040

0.6 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 30 EVT041

1 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 30 EVT042

2 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 30 EVT043

5 m orangePVC cable 4 x 0.34 mm2, Ø 4.9 mm

PVC / st. steel316L / 1.4404

250 AC300 DC

-25...100IP67 / IP68 /

IP69K– 30 EVT044

Socket M12, 5-pole, 5-wire, angled

5 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 31 EVT013

Connection technology

230www.ifm.com

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 5-pole, 5-wire, straight

5 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 32 EVT010

Jumper M12, 5-pole, 5-wire, straight / straight

0.3 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 33 EVT058

1 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 33 EVT060

2 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 33 EVT061

5 m orangePVC cable 5 x 0.34 mm2, Ø 5.1 mm

PVC / st. steel316L / 1.4404

30 AC36 DC

-25...100IP67 / IP68 /

IP69K– 33 EVT062

Connectors for hazardous areas

Type Cable Wirespecification

Materialhousing/

nut

U

[V]

Ta

[°C]

Pro-tection

LEDs Draw-ingno.

Orderno.

Socket M12, 4-pole, 4-wire, angled

5 m bluePUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 8 ENC05A

Socket M12, 4-pole, 4-wire, straight

5 m bluePUR cable 4 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 9 ENC02A

Socket M12, 5-pole, 5-wire, angled

5 m bluePUR cable 5 x 0.34 mm2, Ø 4.9 mm

TPU /brass

...30 DC -25...90 IP67 – 34 ENC11A

Scale drawings - CAD download: www.ifm.com

1

9

10 31

M8x1

2

9

10 19

M8x1 25,5

3

9

10 19

M8x1 25,5

LED

4

9

10 31

M8x1

Connection technology

231www.ifm.com

Scale drawings - CAD download: www.ifm.com

5

9

10 19

M8x1 25,5

6

35

18

20

M12 x1

30

7

18

M12 x1

46

8

15,5

M12x1 36,5

26,5

14

9

15,5

M12x1 45

14

10

43

15

M12 x1

11

15

38

M12 x1

28

10,5

12

4520

M16x1

49

13

27

10,5

15

39

G 21

14

42

10,5

15

G 21

15

27

10,5

15

39

"-20UNF21

16

42

18

15

20

M12 x1

31

Connection technology

232www.ifm.com

Scale drawings - CAD download: www.ifm.com

17

5220

M12 x1

18

15,5

M12x1 49,5

14

19

1 2

43PWR

18224,

773

118,

234

55

4,5

28,539

7,5

60

M12x1

20

1 2

4

6

3

5

PWR

18224,

773

125

34

55

4,5

28,539

7,5

60

M12x1

21

1 2

4

6

8

3

5

7

PWR

18224,

773

152

34

55

4,5

28,539

7,5

60

M12x1

22

15,5

M12x1 36,5

26,5

143 LED

23

18

9

28

M8 x1

10

24

10

M8 x1

31

9

25

18

9

28

M8 x1

10

Connection technology

233www.ifm.com

Scale drawings - CAD download: www.ifm.com

26

10

M8 x1

31

9

2715

,5

M12x1 36,5

26,5

14

28

15,5

45

14

M12 x1

29

15,5

M12x1 36,5

26,5

14LED

30

L

15,5

M12 x1

49

14

45

15,5

M12 x1 14

31

15,5

M12x1 36,5

26,5

14

32

15,5

45

14

M12 x1

33

L

15,5

M12 x1

49

14

45

15,5

M12 x1 14

34

15,5

M12x1 36,5

26,5

14

Connection technology

234www.ifm.com

Connection technology

235

ifm – worldwideaddresses

236www.ifm.com

Argentinaifm electronic s.r.l.Manuela Sáenz 3235º piso, oficina 3C1107BPA - Puerto MaderoBuenos Aires, ArgentinaTel. (011) 5353-3436Fax (011) 5353-3436Interior [email protected]/ar

Australiaifm efector pty ltd.P.O. Box 4084Suite 3, 745 Springvale RoadMulgrave VIC 3170Tel. 1300 365 088Fax 1300 365 [email protected]

Austriaifm electronic gmbhWienerbergstraße 41Gebäude E1120 ViennaTel. +43 / 1 / 617 45 00Fax +43 / 1 / 617 45 00 [email protected]/at

BangladeshSensotec AutomationRed Crescent Chamber87, Motijheel CommercialAreaDhaka 1000BangladeshTel. +880 171 546 [email protected]

BelarusDEPOSIT INVESTJoint-Stock CompanyBlock 2, 27 Zheleznodorovhnaya street220089 MinskRepublic of BelarusTel. +375-17-270 75 06Fax +375-17-270 75 [email protected]

Belgium andLuxembourgifm electronic n.v./s.a.Zuiderlaan 911731 ZellikBelgiëTel. +32 2 481 0220Fax +32 2 463 [email protected]/be

BoliviaBAVARIA S.R.L.Álvaro Baptista VargasZona Morocollo, Urb. SantosPariamoC. Mario Diaz de medina (26-A), Nr. 32La Paz - BoliviaTel.: 00-591-2-277 13 78Mobile: 00-591-720-47 [email protected]

Brazilifm electronic Ltda.Rua Eleonora Cintra, 140Jardim Analia Franco03337-000 São Paulo/SPTel. +55-11-2672-1730Fax [email protected]/br

Bulgariaifm electronic eoodul. Slatinska Nr. 92 A, ap. 2/31574 SOFIATel. +359 2 807 59 69Fax. +359 2 807 59 [email protected]

Canadaifm efector Canada Inc. 700 Dorval Drive/CorporateCentreOakville; L6K3V3 OntarioTel. +1-800-441-8246 Fax [email protected]

ChileElectronica IndustrialSchädler y Cia. Ltda.Av. Antonio Varas 1871Providencia6641545 SantiagoTel. +56 / 2 / 274 74 30Fax +56 / 2 / 204 93 [email protected]

Chinaifm electronic (Shanghai)Co., LtdBuilding 15, No 912Bi Bo Road, Pu Dong DistrictShanghai 201210, ChinaTel. +86-21-50278559 Fax +86-21-50278669Fax [email protected] www.ifm.com/cnifm electronic (HK) LtdUnit 2106, 21/F, Tower 2, MetroplazaNo. 223 Hing Fong Road, Kwai Chung, N.T., Hong Kong.Telefon: +852 3528-0462Fax: +852 [email protected]/hkifm electronic (Taiwan)Limited2C, Bao-Cheng EnterpriseTower,No. 6 Mincyuan Second Road,Cianjhen District, KaohsiungCity,Postal Code 806, Taiwan,R.O.C.Tel.: +886-7-335-7778Fax: [email protected]/tw

ColumbiaSENSOMATIC Y CIA LTDA.CALLE 1 C 25a - 50BOGOTA D.C. COLOMBIATel. +57 313 430 2264and +57 1 407 96 [email protected]://www.sensomatic-ltda.com

Croatiaifm electronic gmbhWienerbergstr. 41Gebäude EA-1120 WienTel. +43 / 1 / 617 45 00Fax +43 / 1 / 617 45 00 [email protected]/hr

Czech Republicifm electronic spol.s.r.o.U Křížku 571252 43 PragueTel. +420 / 2 / 67 990 211 Fax +420 / 2 / 67 750 180 [email protected]/cz

Denmarkifm electronic a/sRingager 4A, 1.sal tv.2605 BrøndbyTel. +45 70 20 11 08Fax +45 70 20 11 [email protected]/dk

Dominican RepublicWECH AUTOCONTROLES S. A.Ave. Romulo Betancourt 2158 Edificio WechUrb. RenacimientoSanto DomingoDominican RepublicTel.: + 1 809-531-0550Fax: + 1 [email protected]

EcuadorINSELEC CIA. LTDA.Av. de los AruposE1-202 y Pan. Norte- Km 5 ½QuitoTel. +593 2 28074- 76 - 78Fax +593 2 [email protected]

EgyptEgyptian Establishment forElectromechanical SuppliesMr. Ahmed Gouda27 Al-Salam StreetAl Arezona, Al Haram RoadGiza 12111, CairoTel. +20 / 2 / 586 49 49Fax +20 / 2 / 586 49 49Mobile +20 10 10 61 [email protected]

EstoniaPesmel Estonia LTDSegu 476505 SaueEstoniaTel.: +372 674 73 30 Fax: +372 674 73 [email protected]

Finlandifm electronic oyVaakatie 5 00440 Helsinki Tel. +358 / 9 / 751 777 00 Fax +358 / 9 / 751 777 10 [email protected]/fi

Franceifm electronicSiège :Savoie Technolac BP22673374 Le Bourget du LacAgence commerciale :Immeuble Uranus1-3 rue Jean Richepin93192 NOISY LE GRANDCEDEXTél: 0820 22 30 01Fax: 0820 22 22 [email protected]/fr

Germanyifm electronic gmbhFriedrichstr. 145128 EssenTel. +49 201 24 22 0Fax +49 201 24 22 12 [email protected]/de

Greeceifm electronic monoprosopiE.P.E.27, Andrea Papandreou Street15125 AmaroussiGreeceTel +30 210 61 800 90Fax +30 210 61 994 [email protected]/gr

HondurasR y D INDUSTRIALBo. Paz Barahona11 Ave. 14 y 15 CalleS.O. #142San Pedro SulaTelefon:+504 5503703Telefax:+504 [email protected]

Hungaryifm electronic kft.Közép u. 16. II.em. 208. irodaH-9024 GyőrTel. +36-96 / 518-397Fax +36-96 / [email protected]/hu

Indiaifm electronic India Pvt. Ltd.Plot No. P-39/1MIDC Gokul ShirgaonKolhapur – 416234Maharashtra State, IndiaTel. +91 / 231 / 267 27 70Fax +91 / 231 / 267 23 [email protected]/in

IndonesiaPT Indoserako SejahteraJl. P. Jayakarta 121 No. 5910730 Jakarta PusatTel. +62 / 21 6 24 8923Fax +62 / 21 6 24 [email protected]

Irelandifm electronic (Ireland) Ltd.No. 7, The CourtyardKilcarbery Business ParkNew Nangor RoadClondalkinDublin 22Tel. +353 / 1 / 413 60 66Fax +353 / 1 / 457 38 [email protected]/ie

IsraelAstragal Ltd.3, Hashikma Str.Azur 58001P.O. Box 99Azur 58190Tel. +972 / 3 / 5 59 16 60Fax +972 / 3 / 5 59 23 [email protected]

Italyifm electronicCentro Direzionale ColleoniPalazzo Andromeda 2Via Paracelo n° 1820041 Agrate Brianza (Milano)Tel. +39 / 039 68 99 982Fax +39 / 039 68 99 [email protected]/it

Japanefector co. ltd.Chiba Higashi Techno Green Park2-9-20 OkayamadaiTogane-shi, Chiba 283-0826Tel. +81 / 475 50 3003Fax +81 / 475 50 [email protected]/jp

JordanAl Mashreqan Trading SuppliesP.O.Box.85105411185 SwaifiehAmman - Jordan.Tel. +962 6 581 8841Fax +962 6 581 [email protected]

Koreaifm electronic Ltd.2F Hyundai Liberty House#201Hannam-Dong 258,Yongsan-Gu,Seoul, KoreaTel +82 2-790-5610Fax +82 [email protected]/kr

LatviaEC SystemsKatlakalna Str. 4A1073 RigaLatviaTel.: +371 724 1231Fax: +371 724 [email protected]

ifm – worldwideaddresses

237www.ifm.com

LebanonMiddle East DevelopmentCo. SAL (MEDEVCO)Medevco Building Jeita Main Road Jeita - Kesrouan LebanonMail address :P.O.Box 67 Jounieh LebanonTel + 961-9-233550 Fax + 961-9-233554 [email protected]

LithuaniaElinta UABTerminalo g. 3, Biruliškių k.,Karmėlavos sen.LT-54469 Kauno raj. (Kauno LEZ)LithuaniaTel.: +370 37 351 999Fax: +370 37 452 [email protected]

Malaysiaifm electronic Pte. LtdMalaysian Branch OfficeNo. 2-4-2, Fourth FloorTower 2 @ PFCC, Jalan Puteri 1/2,Bandar Puteri Puchong,47100 Puchong, Selangor.Tel. +60 / 3 / 8063 9522Fax +60 / 3 / 8063 [email protected] electronicAsia Regional OfficeNo. 21, Jalan Kemunting,Taman Kebun The80250 Johor BahruJohor, West MalaysiaTel. +60 / 7 / 332 5022Fax +60 / 7 / 332 [email protected]

Mexicoifm efector S. de R.L. de C.V.Anillo Periférico, 1816-1Col. Hacienda San JerónimoMonterrey, N.L.Mexico 64630Tel. +52-81-8040-3535Fax +52-81-8040-2343www.ifmefector.mx

Netherlandsifm electronic b.v.Deventerweg 1 E3843 GA HarderwijkTel. +31 / 341 438 438Fax +31 / 341 438 [email protected]/nl

New Zealandifm efector pty ltd.Unit B, 20 Cain RoadPenrose, AucklandTel. +64 / 95 79 69 91Fax +64 / 95 79 92 [email protected]/nz

NigeriaAutomated Process Ltd3rd Floor, 32 Lagos AbeokutaExpresswayNear Cement Bus StopDopemu, AgegeLagos State, NigeriaTel. + 234 / 01 / 4729 967Fax + 234 /01 / 4925 [email protected]

NorwaySiv.Ing. J.F.Knudtzen ASBillingstadsletta 971396 BillingstadPostboks 1601378 NesbruTel. +47 / 66 98 33 50Fax +47 / 66 98 09 [email protected]

OmanTechnical Engineering Company LLC.P.O.Box. 59 Madinat Al Sultan QaboosPostal Code 115 Sultanate of OmanTel + 968 24503593Fax + 968 [email protected]

PakistanAB AutomationShop No.2. Rubab ChamberM.A. Jinnah RoadOff Sarai RoadKarachiTel. +92 / 21 / 2412 278Fax +92 / 21 / 2422 [email protected]

Perudekatec s.a.c.Los Calderos 188Urb. Vulcano, AteLima / PeruTel. +511 / 348 0293Tel. +511 / 348 0458Tel. +511 / 348 2269Fax +511 / 349 [email protected]

PhilippinesGram Industrial, Inc.Unit 410 Common GoalTowerFinance cor. Industry St.,Madrigal Business Park,Ayala Alabang, MuntinlupaCity1770 Philipines Tel. (+63) 2 850-2218Fax (+63) 2 [email protected]

Polandifm electronic Sp.z o.o.ul. Kosciuszki 175PL 40-524 KatowiceTel. +48 / 32 / 60 87 454Fax +48 / 32 / 60 87 [email protected]/pl

Portugalifm electronic –Sucursal em PortugalAvenida da Republica 25034430-208 Vila Nova de GaiaTel. +351 / 22 / 37 17 108Fax +351 / 22 / 37 17 [email protected]/pt

Romaniaifm electronic s.r.l.Str. Cristian Nr. 5550073 SibiuTel.: 0040 269 224550Fax: 0040 269 [email protected]

Russiaifm electronicIbragimova, 31, k.50office 607105318 MoscowTel.: +7 (495) 921-44-14Fax: +7 (495) [email protected]/ru

Saudi ArabiaNoor Al-Shomoe for Electric& MaintenanceKing Khalid Street, Cross 5P.O. Box 2571Al-Khobar 31952Kingdom of Saudi ArabiaTel. +9 663 864 49 58Fax +9 663 894 63 [email protected]

Singaporeifm electronic Pte. Ltd.25, Intern. Business Park#03-104 German Center609 916 SingaporeTel. +65 / 6 / 5 62 86 61Fax +65 / 6 / 5 62 86 [email protected]/sg

Slovakiaifm electronic spol. s.r.o.Rybnicna 40831 06 BratislavaTel. +421 / 2 / 44 87 23 29Fax +421 / 2 / 44 64 60 [email protected]/sk

South Africaifm electronic (pty) LtdShorrok HouseRoute 21 Corporate ParkNellmapius Drive, Irene Ext. 30, Centurion 0157, Pretoria Postnet Suite 279Private bag X8Elardus Park0047Tel. +27 (0) 861 IFM RSA /436 772Fax +27(0)12 450 [email protected]/za

Spainifm electronic s.l.Edificio Prima Muntadas AParc Mas BlauC/Berguedà 108820 El Prat de LlobregatTel. +34 / 93 / 479 30 80Fax +34 / 93 / 479 30 [email protected]/es

Swedenifm electronic abHallavägen 10 512 60 Överlida Office Gothenburg:Drakegatan 641250 GothenburgTel. +46 / 325 / 66 15 00 Tel. +46 / 325 / 66 15 50Fax +46 / 325 / 66 15 [email protected]/se

Switzerlandifm electronic agAltgraben 274624 HärkingenTel. +41 / 62 / 388 80 30Fax +41 / 62 / 388 80 [email protected]/ch

SyriaI.E.C. Industrial EngineeringCenterP.O. Box 15 Sehnaya, DamascusSyriaTel. + 963 11 532 13 19Fax. + 963 11 442 12 [email protected]

ThailandSang Chai Meter Co., Ltd.694/16-19 Phaholyothin RoadSamsen Nai, Phayathai Bangkok 10400 Tel. +66 / 2 / 616 8051Fax +66 / 2 / 616 [email protected]

Turkeyifm electronic Elektrikli ve Elektronik Aletlerİth.İhr.Paz.Tic.Ltd.Şti. Merkez Mah. Nadide Sok. Anıttepe Sitesi No:28 34381 Şişli / İstanbulTel. +90 / 212 / 210 5080Fax +90 / 212 / 221 [email protected]/tr

Ukrainaifm electronicMariny Raskovoj 1102660 KievUkraineTel. +380 44 501 8543Fax +380 44 501 [email protected]/ua

United Arab EmiratesNoor Al-Shomoe ElectricalEquipments Est.P.O.Box. 64052Unit no. 36Reef Real EstateJebel Ali Industrial Area no. 3DubaiUnited Arab EmiratesTel.. + 971 4 880 3838Fax.+ 971 4 880 3883Mobile: + 971 [email protected] Arab Emirates –Abu DhabiAl Injazat Technical Trading ServicesP.O. Box 42895Abu DhabiUnited Arab EmiratesTel. +971 2 622 6030Fax +971 2 622 [email protected]

United Kingdomifm electronic Ltd.efector HouseKingsway Business ParkOldfield RoadHamptonMiddlesex TW12 2HDTel. +44 / 20 / 8213 0000Fax +44 / 20 / 8213 [email protected]/uk

USAefector inc.805 Springdale Drive Exton, PA 19341 Tel. +1 / 610 524 2000 Fax +1 / 610 524 [email protected]

VenezuelaPetrobornas, C.A.C.C. Los Pinos - Local EAv. Principal de la UD 304(8015) - Puerto Ordaz - Edo.BolivarVenezuelaTel. +58 286 994 3406Tel. +58 416 686 5036Fax +58 286 994 [email protected]

VietnamThien Viet Electrical Serviceand Trading Co., Ltd.784 Dien Bien Phu Str.Ward 11, Dist. 10Ho-Chi-Minh-City, Viet NamTel. +84 / 8 / 830 9916 Fax +84 / 8 / 830 [email protected]

www.ifm.com