Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited. A1 Building, ShenZhen Low Carbon Technology Park, GuiYue Road, ZhangGe Village, GuanLan Town, LongHua New Area, Shenzhen Model:5050 Report Type: 6000 Hours Test Report Product Type: LED Package Test Engineer: Daniel Duan Report Number: R2DG130610050-10 Test Date: 2013-06-10 to 2014-02-18 Report Date: 2014-02-19 Reviewed By: Jeanne Han /Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Dongguan). Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Tel: +86-0769-86858888 Fax:+86-0769-86858588

Upload: others

Post on 15-Mar-2020

7 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: IESNA LM-80-2008 - GENLED brandsReport No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal

Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).

IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

MEASUREMENT AND TEST REPORT

For Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited.

A1 Building, ShenZhen Low Carbon Technology Park, GuiYue Road, ZhangGe Village, GuanLan Town, LongHua New Area, Shenzhen

Model:5050

Report Type:

6000 Hours Test Report

Product Type:

LED Package

Test Engineer: Daniel Duan

Report Number: R2DG130610050-10

Test Date: 2013-06-10 to 2014-02-18

Report Date: 2014-02-19

Reviewed By: Jeanne Han /Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Dongguan). Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Tel: +86-0769-86858888 Fax:+86-0769-86858588

Page 2: IESNA LM-80-2008 - GENLED brandsReport No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal

Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited. Model:5050

Report No. R2DG130610050-10 Page 2 of 8 IES LM-80-08 Test Report

TABLE OF CONTENTS

1 - GENERAL INFORMATION.................................................................................................................................. 3

1.1 DESCRIPTION OF LED LIGHT SOURCES .................................................................................................................. 3 1.2 STANDARDS USED .................................................................................................................................................. 3 1.3 TEST FACILITY ....................................................................................................................................................... 3 1.4 DESCRIPTION OF AUXILIARY EQUIPMENT .............................................................................................................. 3 1.5 OPERATING CYCLE ................................................................................................................................................. 3 1.6 AMBIENT CONDITIONS ........................................................................................................................................... 4 1.7 PHOTOMETRY MEASUREMENT UNCERTAINTY ....................................................................................................... 4 1.8 SAMPLE SET ........................................................................................................................................................... 4

2 - SUMMARY OF TEST RESULT ............................................................................................................................ 5

3.1 DATA SET 1, 85°C, 60MA (LUMEN MAINTENANCE) .............................................................................................. 6 3.2 DATA SET 1, 85°C, 60MA (CHROMATICITY SHIFT) ................................................................................................ 7

APPENDIX A – EUT PHOTO ..................................................................................................................................... 8

A.1 MECHANICAL DIMENSIONS (TA = 25°C) ............................................................................................................... 8 A.2 EUT PHOTO .......................................................................................................................................................... 8

Page 3: IESNA LM-80-2008 - GENLED brandsReport No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal

Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited. Model:5050

Report No. R2DG130610050-10 Page 3 of 8 IES LM-80-08 Test Report

1 - GENERAL INFORMATION

1.1 Description of LED Light Sources

Devices tested

Part Number: 5050 Part Name: / Part Type: LED Package

Nominal CCT: 3000K

1.2 Standards Used

x IESNA LM-80-08: IES Approved Method for Measuring Lumen Maintenance of LED Light Sources.

x ENERGY STAR® Program Guidance Regarding LED Package, LED Array and LED Module Lumen Maintenance Performance Data Supporting Qualification of Lighting Products(This test method was not accredited by IAS)

1.3 Test Facility

The testing facility used by Bay Area Compliance Laboratories Corp. (Dongguan). is located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

1.4 Description of Auxiliary Equipment

Device Manufacture Model No Serial No Test Range Calibration date

Calibration due date

Integral Sphere EVERFINE Diameter 0.3M 1011119

380-780nm, length:0.3M ,0-1999LUMEN

2013-03-08 2014-03-08

Programmable Test Power for LEDs EVERFINE LED300E 1008002 15V/2000mA 2013-03-25 2014-03-25

High accuracy array spectroradiometer EVERFINE HAAS-2000 1012016T 380-780nm 2013-03-08 2014-03-08

Standard Light Source EVERFINE D062 1011064 2856K 2013-05-23 2014-05-23

Precision digital stabilized DC power

supply EVERFINE WY605 G115987CJ

7321114 300VA 2013-03-25 2014-03-25

Multilayer LM-80 aging machine BACL B2-270 20005 270pcs 2013-08-01 2014-08-01

Multi-channel DC source

Tai Shan Xing Guang T0100F ST04387 5V/100mA 2013-03-26 2014-03-26

1.5 Operating Cycle

Samples are driven with a constant direct current (DC)

Page 4: IESNA LM-80-2008 - GENLED brandsReport No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal

Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited. Model:5050

Report No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report

1.6 Ambient Conditions

For lumen maintenance test, samples were operated in thermal chambers with minimal ambient airflow. For long term reliability test, the case temperature was controlled by mounting several thermocouples on a sample reliability stress board at the designated thermal measurement point, as shown in APPENDIX. The ambient temperature TA was measured by several thermocouples at a distance of 1.5 mm above the reliability test board. The relative humidity within chamber was less than 65%.

For photometry measurement, temperature was set to 25°C ± 2°C, RH <65%.

1.7 Photometry Measurement Uncertainty

The uncertainty of the light output measurements is U=1.59% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. This calibration results traceable to the NATIONAL INSTITUTE OF METROLOGY (NIM).

1.8 Sample Set

Sampling Method:

LED samples for IESNA LM-80 testing consist of units built from a minimum of three manufacturing lots with each manufacturing lot built from different wafer lots built on non-consecutive days.

These manufacturing lots are picked to represent a wide parametric distribution.

Each Sample is soldered to all of the reliability stress boards for a given set of IESNA LM-80 tests.

Sample Size:

Total 25Pcs;

The 25pcs samples tested only at 85°C, was received at 2013-06-10 and tested during 2013-06-10 to 2014-02-18. The samples were numbered from 1 to 25.

Data Set : 85°C, 60mA Part Number: 5050

Number of Units: 25

Actual Case Temperature(TS): TS = 84.6°C

Actual Ambient Temperature(TA): TA = 81.3°C

Life Test Drive Current: IF = 60mA

Measurement Current: IF = 60mA

Page 5: IESNA LM-80-2008 - GENLED brandsReport No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal

Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited. Model:5050

Report No. R2DG130610050-10 Page 5 of 8 IES LM-80-08 Test Report

2 - SUMMARY OF TEST RESULT

Data Set: Data Set 1, 85°C, 60mA

Number of Units: 25

Failures Observed: 0

Average. Lumen Maintenance at 6000 hours: 96.38%

Average Chromaticity Shift at 6000 hours (∆u’v’): 0.0017

Reported TM-21 L70 Lifetime: >36,000 hours

Page 6: IESNA LM-80-2008 - GENLED brandsReport No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal

Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited. Model:5050

Report No. R2DG130610050-10 Page 6 of 8 IES LM-80-08 Test Report

3 - Test Data

3.1 Data Set 1, 85°C, 60mA (Lumen Maintenance)

No. VF(V) Φ(lm) Lumen Maintenance (%)

0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs

1 3.239 20.90 100.05 99.38 99.00 97.70 97.56 96.56

2 3.234 21.24 99.86 99.53 98.87 97.83 97.46 96.47

3 3.253 21.30 99.95 99.48 98.73 97.98 97.28 96.01

4 3.242 21.05 99.81 99.38 98.72 97.72 97.34 96.01

5 3.238 21.12 99.91 99.57 98.82 97.63 97.16 96.07

6 3.233 21.34 99.81 99.30 98.88 97.80 97.61 96.63

7 3.233 19.90 100.00 99.65 98.84 97.54 97.49 96.18

8 3.231 21.31 99.91 99.39 98.69 97.98 97.61 96.90

9 3.242 20.60 99.85 99.51 98.83 97.72 97.43 96.84

10 3.237 20.63 100.15 99.66 98.93 98.16 97.58 96.46

11 3.233 21.38 99.95 99.49 98.88 97.66 97.24 96.21

12 3.250 21.08 100.09 99.34 98.72 97.87 97.01 96.11

13 3.238 21.33 100.00 99.34 98.69 98.03 97.47 96.72

14 3.234 21.39 100.09 99.53 98.74 97.66 97.29 96.54

15 3.248 21.30 100.09 99.53 98.64 97.93 97.18 96.24

16 3.250 21.36 100.05 99.49 99.02 98.13 97.38 96.63

17 3.244 21.14 99.91 99.48 98.86 97.82 97.30 96.31

18 3.247 20.91 99.95 99.23 98.76 98.13 97.08 96.08

19 3.246 21.21 100.05 99.48 98.87 97.93 97.36 96.65

20 3.247 21.26 100.00 99.39 99.06 97.93 97.32 96.71

21 3.241 21.21 99.91 99.34 99.06 97.97 97.08 96.18

22 3.234 21.14 99.81 99.24 98.82 97.78 97.35 96.36

23 3.235 21.02 99.90 99.33 98.86 97.81 97.29 96.10

24 3.248 21.14 99.86 99.20 98.86 97.63 97.07 95.98

25 3.230 21.10 100.09 99.62 98.63 97.68 97.30 96.49

Ave. 3.240 21.09 99.96 99.44 98.83 97.84 97.33 96.38

Med. 3.239 21.14 99.95 99.48 98.84 97.82 97.32 96.36

st dev 0.0069 0.3250 0.1015 0.1285 0.1218 0.1721 0.1713 0.2811

Min. 3.230 19.90 99.81 99.20 98.63 97.54 97.01 95.98

Max. 3.253 21.39 100.15 99.66 99.06 98.16 97.61 96.90

TM-21 Projection:

Test Duration: 6000 hours Failures Observed: 0

α: 7.336E-06 β: 1.008

Calculated L70: 50,000 hours Reported L70: >36,000 hours

Page 7: IESNA LM-80-2008 - GENLED brandsReport No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal

Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited. Model:5050

Report No. R2DG130610050-10 Page 7 of 8 IES LM-80-08 Test Report

3.2 Data Set 1, 85°C, 60mA (Chromaticity Shift)

No. u’ v’ CCT(K) Chromaticity Shift (∆u’v’)

0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs

1 0.2520 0.5302 2915 0.0003 0.0004 0.0005 0.0012 0.0016 0.0017

2 0.2526 0.5309 2899 0.0005 0.0006 0.0008 0.0013 0.0013 0.0016

3 0.2528 0.5313 2890 0.0004 0.0006 0.0007 0.0010 0.0011 0.0018

4 0.2512 0.5268 2953 0.0001 0.0006 0.0009 0.0014 0.0017 0.0018

5 0.2518 0.5301 2920 0.0004 0.0004 0.0009 0.0014 0.0016 0.0019

6 0.2513 0.5299 2933 0.0005 0.0007 0.0012 0.0014 0.0015 0.0015

7 0.2479 0.5287 3019 0.0004 0.0007 0.0011 0.0012 0.0013 0.0017

8 0.2487 0.5269 3010 0.0003 0.0006 0.0008 0.0013 0.0014 0.0014

9 0.2525 0.5286 2913 0.0005 0.0007 0.0008 0.0012 0.0013 0.0016

10 0.2520 0.5294 2919 0.0006 0.0008 0.0011 0.0015 0.0016 0.0019

11 0.2501 0.5290 2965 0.0001 0.0004 0.0008 0.0012 0.0015 0.0017

12 0.2519 0.5284 2927 0.0006 0.0008 0.0011 0.0014 0.0017 0.0019

13 0.2510 0.5291 2944 0.0001 0.0006 0.0011 0.0013 0.0016 0.0018

14 0.2521 0.5295 2916 0.0002 0.0007 0.0009 0.0010 0.0013 0.0015

15 0.2516 0.5273 2940 0.0001 0.0005 0.0012 0.0013 0.0017 0.0019

16 0.2509 0.5293 2945 0.0005 0.0007 0.0009 0.0010 0.0010 0.0013

17 0.2527 0.5288 2906 0.0005 0.0006 0.0008 0.0011 0.0013 0.0014

18 0.2529 0.5290 2902 0.0003 0.0004 0.0011 0.0015 0.0017 0.0019

19 0.2512 0.5285 2942 0.0004 0.0006 0.0008 0.0012 0.0013 0.0017

20 0.2504 0.5263 2973 0.0004 0.0005 0.0007 0.0012 0.0015 0.0018

21 0.2503 0.5272 2971 0.0004 0.0006 0.0008 0.0011 0.0015 0.0019

22 0.2506 0.5273 2964 0.0004 0.0006 0.0010 0.0014 0.0015 0.0018

23 0.2512 0.5290 2940 0.0003 0.0004 0.0008 0.0014 0.0016 0.0017

24 0.2527 0.5294 2902 0.0005 0.0007 0.0010 0.0014 0.0016 0.0017

25 0.2510 0.5281 2951 0.0003 0.0004 0.0010 0.0013 0.0013 0.0016

Ave. 0.2513 0.5288 2938 0.0004 0.0006 0.0009 0.0013 0.0015 0.0017

Med. 0.2513 0.5290 2940 0.0004 0.0006 0.0009 0.0013 0.0015 0.0017

st dev 0.0012 0.0013 32.8340 0.0001 0.0001 0.0002 0.0001 0.0002 0.0002

Min. 0.2479 0.5263 2890 0.0001 0.0004 0.0005 0.0010 0.0010 0.0013

Max. 0.2529 0.5313 3019 0.0006 0.0008 0.0012 0.0015 0.0017 0.0019

Page 8: IESNA LM-80-2008 - GENLED brandsReport No. R2DG130610050-10 Page 4 of 8 IES LM-80-08 Test Report 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal

Shenzhen Yuliang Optoelectrnic Industrial Co.,Limited. Model:5050

Report No. R2DG130610050-10 Page 8 of 8 IES LM-80-08 Test Report

Appendix A – EUT PHOTO

A.1 Mechanical Dimensions (Ta = 25°C)

Unit: mm

A.2 EUT Photo

***********END OF REPORT***********