ies lm-79-08 - atg electronics lm-79-08 measurement and test report for atg electronics corp. 9020...

12
STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp. 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: FPUS22-40W-3K Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Power Factor, Off-state Power Test Engineer: Daniel Duan Report Number: RSZ150427507-10 Test Date: 2015-05-15 to 2015-05-19 Report Date: 2015-05-19 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

Upload: duongnguyet

Post on 12-Mar-2018

223 views

Category:

Documents


1 download

TRANSCRIPT

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.

(Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification,

approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

IES LM-79-08

MEASUREMENT AND TEST REPORT For

ATG Electronics Corp. 9020 Rancho Park Court Rancho Cucamonga, CA 91730

Test Model: FPUS22-40W-3K

Report Type:

Electrical and Photometric tests including: Luminous Flux,

Color, Luminous Intensity Distribution, THD, Power

Factor, Off-state Power

Test Engineer: Daniel Duan

Report Number: RSZ150427507-10

Test Date: 2015-05-15 to 2015-05-19

Report Date: 2015-05-19

Reviewed By: Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)

6/F, the 3rd Phase of WanLi Industrial Building,

ShiHua Road, FuTian Free Trade Zone

Shenzhen, Guangdong, China

Tel: +86-755-33320018

Fax: +86-755-33320008

Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial

Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation: The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 2 of 12 The NVLAP Lab Code is 200707-0.

1. Product Description

General Information:

One sample was received on 2015-04-27 and used for testing. Sample No.: RSZ150427507-S01 Model: FPUS22-40W-3K

Model Tested: FPUS22-40W-3K

Manufacturer: ATG Electronics Corp.

Brand Name: ATG

Product Designation: 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces

Burning Time Before Test: 0 hour(For New Products)

Rated Values:

Rated Voltage/Frequency: AC100-277 V 50/60Hz

Rated Power: 40W

Nominal CCT: 3500K

2. Standards Used

IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration

due date

Integrating

Sphere SENSING SPR-600 S09008 1.5 meter 2015-03-16 2016-03-16

Spectral

photometer SENSING SPR3000 90902027 380nm~800nm 2015-03-16 2016-03-16

Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2015-03-05 2016-03-05

AC Power Supply ALL Power APW-

105N 970613 0V-300V 50-400Hz 2015-03-05 2016-03-05

Standard Light

Source EVERFINE D204 LSD090808 N/A 2014-08-05 2015-08-05

Thermal Meter SENSING N/A N/A 25℃,45℃,55℃ 2015-03-05 2016-03-05

DC Power Supply ITECH IT6154 0061 0417 6471 0010

19 0~60V 2015-03-05 2016-03-05

AC Power Supply EVERFINE VPS1060

PWM 1101006 0-150V, 0-300V 2015-03-12 2016-03-12

DC Power Supply EVERFINE WY12010 1009009 30V/5A 2015-03-05 2016-03-05

Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2015-03-05 2016-03-05

Goniophotometer EVERFINE GO-R5000 YG108492N10120001 1600mm,3000W/10A 2015-03-04 2016-03-04

Thermal Meter Victor VC230 EE091 0~40℃0~90% 2013-04-01 2016-03-31

Standard Light

Source EVERFINE D908 1012004 N/A 2014-07-31 2015-07-31

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been

performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 3 of 12 The NVLAP Lab Code is 200707-0.

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=1.64% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.6 (K=2) , at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

Additional Test

The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at

the 95% confidence level.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 4 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.0 hour

Test orientation: Downward

Electrical Measurement

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

120.03 60.0 0.3349 39.86 0.992

Photometric Measurement

Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

3418.893 10.485 85.773 3529 -2.00E-05

Chromaticity Coordinate

x y u v u' v'

0.4037 0.3899 0.2350 0.3405 0.2350 0.5107

Color Rendering Index

Ra

83.3

R1 R2 R3 R4

82 89 95 83

R5 R6 R7 R8

82 85 86 65

R9 R10 R11 R12

14 74 83 68

R13 R14 R15

84 97 76

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 5 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution

nm mW

nm mW

nm mW

nm mW

nm mW

380 1.389E-03 465 6.659E-02 550 1.522E-01 635 1.573E-01 720 1.864E-02

385 1.341E-03 470 4.967E-02 555 1.588E-01 640 1.463E-01 725 1.610E-02

390 4.885E-04 475 4.433E-02 560 1.639E-01 645 1.340E-01 730 1.376E-02

395 2.144E-04 480 4.570E-02 565 1.713E-01 650 1.207E-01 735 1.195E-02

400 5.000E-04 485 5.146E-02 570 1.783E-01 655 1.086E-01 740 1.004E-02

405 7.399E-04 490 6.107E-02 575 1.857E-01 660 9.709E-02 745 8.881E-03

410 1.536E-03 495 7.436E-02 580 1.922E-01 665 8.444E-02 750 7.595E-03

415 3.844E-03 500 8.637E-02 585 1.982E-01 670 7.248E-02 755 6.675E-03

420 8.392E-03 505 9.801E-02 590 2.019E-01 675 6.185E-02 760 5.845E-03

425 1.671E-02 510 1.080E-01 595 2.066E-01 680 5.430E-02 765 5.132E-03

430 3.225E-02 515 1.159E-01 600 2.047E-01 685 4.814E-02 770 4.445E-03

435 6.311E-02 520 1.222E-01 605 2.023E-01 690 4.368E-02 775 4.021E-03

440 1.181E-01 525 1.276E-01 610 1.970E-01 695 3.865E-02 780 3.424E-03

445 1.747E-01 530 1.319E-01 615 1.915E-01 700 3.327E-02 785 2.894E-03

450 1.568E-01 535 1.366E-01 620 1.856E-01 705 2.906E-02 790 2.734E-03

455 1.105E-01 540 1.400E-01 625 1.784E-01 710 2.552E-02 795 2.427E-03

460 8.568E-02 545 1.448E-01 630 1.683E-01 715 2.109E-02 800 2.085E-03

0.0

0.2

0.4

0.6

0.8

1.0

1.2

380 440 500 560 620 680 740 800

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 6 of 12 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram

7-Step & 4-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50

sample

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

4-STEP 2700K

4-STEP 3000K

4-STEP 3500K

4-STEP 4000K

4-STEP 5000K

4-STEP 6500K

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 7 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.0 hour

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

120.0 60.0 0.3349 39.79 0.9900

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) CBCP (cd) S/MH (C0/180) S/MH (C90/270)

3426.8 86.12 1172 1.28 1.28

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 113.4 114.1 114.4 114.0 114.0

Field Angle (10% Imax): 163.0 163.6 163.6 163.5 163.4

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data

C

0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 1172 1172 1172 1172 1172 1172 1172 1172

5.0° 1169 1170 1170 1169 1169 1168 1167 1166

10.0° 1156 1157 1158 1158 1156 1155 1153 1150

15.0° 1132 1135 1136 1135 1134 1131 1129 1125

20.0° 1100 1103 1104 1104 1102 1099 1095 1091

25.0° 1058 1061 1063 1062 1060 1056 1052 1047

30.0° 1006 1011 1013 1013 1010 1006 1000 993

35.0° 947 951 954 954 951 946 940 931

40.0° 879 884 888 888 885 879 872 862

45.0° 804 810 814 814 811 806 796 786

50.0° 721 728 733 734 731 726 715 704

55.0° 632 640 647 649 646 640 628 616

60.0° 544 546 555 558 555 549 537 526

65.0° 441 450 459 464 462 455 443 430

70.0° 342 351 361 368 366 359 347 334

75.0° 244 253 264 271 270 264 251 239

80.0° 151 160 169 171 170 166 160 149

85.0° 65 72 74 76 75 72 69 65

90.0° 2 4 4 4 3 3 3 2

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 0 0 0 0 0

115.0° 1 1 1 1 1 0 0 0

120.0° 1 1 1 1 1 1 0 0

125.0° 1 1 1 1 1 1 1 0

130.0° 0 0 1 1 1 1 1 0

135.0° 0 1 1 1 1 1 1 1

140.0° 0 1 1 1 1 1 1 1

145.0° 0 1 0 1 1 1 0 1

150.0° 1 1 1 1 1 1 1 1

155.0° 1 1 1 1 1 1 1 1

160.0° 1 1 1 1 1 1 1 1

165.0° 1 1 1 1 1 1 1 1

170.0° 1 1 1 2 1 1 1 1

175.0° 1 1 1 1 1 1 1 1

180.0° 1 1 1 1 1 1 1 1

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.)

C

180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 1172 1172 1172 1172 1172 1172 1172 1172

5.0° 1165 1165 1164 1164 1165 1166 1167 1167

10.0° 1152 1151 1151 1150 1151 1153 1155 1157

15.0° 1125 1123 1123 1122 1124 1126 1129 1132

20.0° 1089 1086 1085 1085 1087 1090 1093 1098

25.0° 1043 1040 1039 1039 1041 1044 1049 1054

30.0° 988 984 984 984 985 990 995 1001

35.0° 924 920 921 921 923 927 934 940

40.0° 853 849 850 851 853 858 865 871

45.0° 775 772 772 774 776 782 788 795

50.0° 692 688 689 692 694 699 705 711

55.0° 604 600 601 604 606 611 616 621

60.0° 511 508 508 512 515 519 523 527

65.0° 416 412 414 418 420 424 426 429

70.0° 320 317 319 323 325 328 328 331

75.0° 226 223 225 229 231 233 232 234

80.0° 137 134 134 133 134 137 140 142

85.0° 54 51 46 43 44 46 50 57

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 0 0 0 0 0

115.0° 0 0 0 0 0 0 0 0

120.0° 0 0 0 0 1 1 1 1

125.0° 0 0 0 1 1 1 1 0

130.0° 0 0 1 1 1 1 1 0

135.0° 0 0 1 1 1 1 1 1

140.0° 0 1 1 1 1 1 1 1

145.0° 0 0 0 1 1 1 0 1

150.0° 0 1 1 1 1 1 0 1

155.0° 0 1 1 1 0 0 1 1

160.0° 0 1 1 1 1 1 1 1

165.0° 0 0 1 1 1 1 1 1

170.0° 0 0 0 1 1 1 1 1

175.0° 1 1 0 0 1 1 1 1

180.0° 1 1 1 1 1 1 1 1

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 10 of 12 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure

Height (m) Diameter

(cm) Eavg(lx) Emax(lx)

0.5 154.0 1348.0 4689.0

1.0 308.0 337.0 1172.0

1.5 462.0 149.8 521.0

2.0 615.9 84.2 293.1

2.5 769.9 53.9 187.6

3.0 923.9 37.4 130.2

3.5 1077.9 27.5 95.7

4.0 1231.9 21.1 73.3

4.5 1385.9 16.6 57.9

5.0 1539.9 13.5 46.9

Angle: 114.00 °. Flux out: 2510.0 lm.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 11 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 28.0 0.82 0-5 28.0 0.82

5-10 83.0 2.42 0-10 111.0 3.24

10-15 135.4 3.95 0-15 246.4 7.19

15-20 183.2 5.35 0-20 429.6 12.54

20-25 224.9 6.56 0-25 654.5 19.10

25-30 259.2 7.56 0-30 913.7 26.66

30-35 284.8 8.32 0-35 1198.5 34.98

35-40 301.1 8.78 0-40 1499.6 43.76

40-45 307.4 8.97 0-45 1807.0 52.73

45-50 303.6 8.86 0-50 2110.5 61.59

50-55 289.7 8.45 0-55 2400.3 70.04

55-60 266.4 7.78 0-60 2666.7 77.82

60-65 234.8 6.85 0-65 2901.5 84.67

65-70 195.9 5.72 0-70 3097.3 90.39

70-75 151.9 4.43 0-75 3249.2 94.82

75-80 104.8 3.06 0-80 3354.0 97.88

80-85 56.4 1.64 0-85 3410.4 99.52

85-90 13.2 0.39 0-90 3423.6 99.91

90-95 0.1 0.00 0-95 3423.8 99.91

95-100 0.1 0.00 0-100 3423.8 99.91

100-105 0.1 0.01 0-105 3423.9 99.92

105-110 0.2 0.00 0-110 3424.1 99.92

110-115 0.2 0.01 0-115 3424.3 99.93

115-120 0.2 0.00 0-120 3424.5 99.93

120-125 0.2 0.01 0-125 3424.8 99.94

125-130 0.2 0.01 0-130 3425.0 99.95

130-135 0.3 0.01 0-135 3425.3 99.96

135-140 0.3 0.00 0-140 3425.5 99.96

140-145 0.3 0.01 0-145 3425.8 99.97

145-150 0.2 0.01 0-150 3426.0 99.98

150-155 0.2 0.00 0-155 3426.2 99.98

155-160 0.2 0.01 0-160 3426.4 99.99

160-165 0.2 0.00 0-165 3426.6 99.99

165-170 0.1 0.01 0-170 3426.7 100.00

170-175 0.1 0.00 0-175 3426.8 100.00

175-180 0.0 0.00 0-180 3426.8 100.00

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150427507-10 Page 12 of 12 The NVLAP Lab Code is 200707-0.

[Additional Test]

Test Item Test Voltage (V) Frequency (Hz) Test Result

Power Factor: 277 60 0.9038

Total Harmonic Distortion: 277 60 7.99%

Total Harmonic Distortion: 120 60 5.37%

Off State Power (W): 120 60 0.0

6. Product Photo

***********END OF REPORT***********