icc-es evaluation report esr-2197*
TRANSCRIPT
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2011 Page 1 of 27
*Corrected May 2011
ICC-ES Evaluation Report ESR-2197* Reissued December 1, 2010
This report is subject to renewal in two years.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®
DIVISION: 05 00 00—METALS Section: 05 05 23—Metal Fastenings Section: 05 31 00—Steel Decking
REPORT HOLDER:
HILTI, INC. 5400 SOUTH 122ND EAST AVENUE TULSA, OKLAHOMA 74146 (800) 879-8000 www.us.hilti.com/decking [email protected] EVALUATION SUBJECT: BARE STEEL DECK AND CONCRETE-FILLED STEEL DECK DIAPHRAGMS ATTACHED WITH HILTI X-ENP-19 L15, X-EDN19 THQ12, OR X-EDNK22 THQ12 FASTENERS 1.0 EVALUATION SCOPE
Compliance with the following codes:
2009 International Building Code® (2009 IBC)
2006 International Building Code® (2006 IBC)*
*The code indicated with an asterisk is addressed in Section 8.0
Property evaluated:
Structural
2.0 USES
Hilti X-ENP-19 L15, X-EDN19 THQ12 and X-EDNK22 THQ12 fasteners are used for the attachment of bare steel deck and concrete-filled steel deck diaphragms to structural steel members.
3.0 DESCRIPTION
3.1 Power-driven Fasteners:
The Hilti fasteners are manufactured from hardened carbon steel with an electroplated zinc coating conforming to ASTM B 633-07, SC 1, Type III.
The X-ENP-19 L15 fasteners are 0.937 inch (23.8 mm) long with a 0.177-inch-diameter (4.5 mm) knurled, tapered shank fitted with two 0.590-inch-diameter (15.0 mm) steel cupped washers. The X-ENP-19 L15 fasteners have a flattened head design to accept a sealing cap.
The X-EDN19 THQ12 and X-EDNK22 THQ12 fasteners are, respectively, 0.827 inch (21.0 mm) and 0.960 inch (24.4 mm) long. Both fasteners have a dome-style head, a 0.472-inch-diameter (12.0 mm) steel flat washer and a steel top hat washer. See Table 1 for fastener drawings.
3.2 Steel Deck Panels:
The steel deck panels must have nominally 11/2-, 2- or 3-inch-deep (38, 51 and 76 mm) flutes. The 11/2-inch-deep (38 mm) panels must have a width of 36 inches (914 mm) with the flutes spaced 6 inches (152 mm) on center, and the sidelaps must be a nestable-type or a standing seam, interlocking-type. The 2-inch-deep (51 mm) panels must have a width of 36 inches (914 mm), with the flutes spaced 12 inches (305 mm) on center and standing seam, interlocking type sidelaps. The 3-inch-deep (76 mm) panels must have widths of 24 or 36 inches (610 and 914 mm), with flutes spaced 8 or 12 inches (203 and 305 mm) on center, respectively, and nestable-type or standing seam, interlocking-type sidelaps. The 11/2-inch-deep (38 mm) steel deck panels must have minimum base-steel, thicknesses of 0.0598, 0.0474, 0.0358 or 0.0295 inch (1.52, 1.19, 0.91 or 0.76 mm) [ 59, 47, 35 or 29 mils (No. 16, 18, 20 or 22 gage)]. The 2-inch-deep (51 mm) steel deck panels must have minimum base-steel thicknesses of 0.0598, 0.0474, 0.0418 or 0.0358 inch (1.52, 1.19, 1.06 or 0.91 mm) [59, 47, 41 or 35 mils (No. 16, 18, 19 or 20 gage)] . The 3-inch-deep (76 mm) steel deck panels must have minimum base-steel thicknesses of 0.0478, 0.0418, 0.0359 or 0.0299 inch (1.21, 1.06, 0.91 or 0.76 mm) [47, 41, 35 or 29 mils (No. 18, 19, 20 or 22 gage)]. Steel deck panels must conform to the requirements of ASTM A 653 SS, Grade 33. Galvanizing must be in accordance with the minimum G60 designation. For steel deck panels installed without concrete fill, the panels may also be painted or phosphatized steel complying with ASTM A 1008-10 SS, Grade 33 (minimum). Steel decks must have deck embossments or indentations for positive interlock with concrete fill.
3.3 Concrete Fill:
The structural concrete fill is either normal-weight or structural sand lightweight, with a minimum 28-day compressive strength, f′c, of 3,000 psi (20.7 MPa), and a minimum thickness above the deck of 2 inches (51 mm). Structural normal-weight concrete fill must contain aggregate complying with ASTM C 33, and have a minimum unit weight of 145 pounds per cubic foot (2323 kg/m3). Structural sand lightweight concrete fill must contain aggregate complying with ASTM C 33 and ASTM C 330 and have a minimum unit weight of 110 pounds per cubic foot (1782 kg/m3).
3.4 Reinforcement:
Steel welded plain wire reinforcement, in accordance with Section 1907.12 of the IBC, must be placed in concrete-filled diaphragms for temperature and shrinkage control. Steel welded plain wire reinforcement must consist of plain
ESR-2197 | Most Widely Accepted and Trusted Page 2 of 27
wires conforming to ASTM A 82-07 fabricated into sheets in accordance with ASTM A 185-07, and be embedded 1 inch (25.4 mm) from the top surface of the concrete slab. Table 19 provides the minimum welded wire reinforcement for allowable concrete-filled diaphragm shears.
3.5 Shear Connectors:
Concrete fill must be positively interlocked to the steel deck below by means of deck embossments, indentations or mechanical anchorages for concrete-filled diaphragms. Shear connectors (studs) must be made of ASTM A 108-07 cold-drawn steel and comply as Type B with specifications of the American Welding Society (AWS) Structural Welding Code—Steel, AWS D1.1.
Studs must be 1/2-, 5/8- or 3/4-inch-diameter (12.7, 15.9 or
19.1 mm) Type B studs with lengths as shown in Table 20. Shear connectors must be installed in accordance with the AISC 360 and AWS D1.1 referenced in Section 2205 of the IBC, with center-to-center spacing not exceeding 36 inches (914 mm). Studs at shear transfer points within the diaphragm or at perimeters must be spaced as required in Table 17 or 18. Shear connectors may substitute for Hilti fasteners where their locations coincide.
3.6 Sealing Cap:
The Hilti SDK2 sealing cap is made from SAE 316 stainless steel with a neoprene washer, and is intended to be installed over the head of the X-ENP-19 L15 fastener. Figure 6 depicts the Hilti SDK2 sealing cap.
3.7 Sidelap Screws:
The screws for steel deck panel sidelap connections must be minimum No. 10 by 3/4-inch-long (19.1 mm), HWH OR HHWH, self-drilling steel screws conforming to ASTM C 1513-10 requirements and manufactured by Hilti, Inc. These fasteners are recognized in ICC-ES evaluation report ESR-2196.
3.8 Supports:
Structural steel supports must consist of minimum ASTM A 36 steel with a base-metal thickness greater than or equal to 1/4 inch (6.4 mm) for the X-ENP-19 L15 fastener; from greater than or equal to 3/16 inch (4.8 mm) to less than or equal to 3/8 inch (9.5 mm) for the X-EDN19 THQ12 fastener; and from greater than or equal to 1/8 inch (3.2 mm) to less than or equal to 1/4 inch (6.4 mm) for the X-EDNK22 THQ12 fastener.
4.0 DESIGN AND INSTALLATION
4.1 Design:
Design information for steel deck panels attached to structural steel supports with Hilti X-ENP-19 L15, X-EDN19-THQ12, and/or X-EDNK22-THQ12, fasteners is found in the tables of this report. Table 1 provides guidance for determining the proper fastener. The required number and placement of fasteners for various spans with allowable diaphragm shears, q, and flexibility factors, F, are shown in Tables 2 through 8 for bare-steel deck diaphragms, and in Tables 10 through 15 for concrete-filled steel deck diaphragms. Nominal shear and flexibility factors for fasteners are provided in Table 21. Allowable uplift loads for fasteners must be the lower of the allowable pullout or pullover strength provided in Tables 22 and 23. The notes after Table 23 describe additional design requirements and limitations. Horizontal distribution of earthquake loads must be established in accordance with Section 12.8.4 of ASCE 7 and diaphragm design forces must be determined in accordance with Section 12.10.1.1 of ASCE 7. The analysis must determine whether the diaphragm is rigid or flexible in accordance with Section
1604.4 of the IBC and Section 12.3 of ASCE 7. The diaphragm design must comply with the requirements in Section 12.3 of ASCE 7. Diaphragm flexibility limitations are shown in Table 24. Varying deck gage and/or connections across a diaphragm is permitted, provided the configuration meets varying shear and flexibility demands. Allowable diaphragm shear values in Tables 2 through 8 are for diaphragms described in this report subjected to earthquake loads or subjected to load combinations which include earthquake loads. Allowable diaphragm shear values found in Tables 2 through 8 must also be limited to the respective ASD (qa) and LRFD (qf) buckling diaphragm capacities found in Table 9. The diaphragm shear in the tables may be increased for other applications as follows:
DESIGN METHOD
FOR
MULTIPLY DIAPHRAGM SHEARS IN TABLE BY1
ASD Diaphragms subjected to wind loads or load combinations which include wind loads
1.06
ASD Diaphragms subject to all other load combinations
1.00
LRFD
Diaphragms subjected to earthquake loads or load combinations which include earthquake loads
1.63
LRFD Diaphragms subjected to wind loads or load combinations which include wind loads
1.75
LRFD Diaphragms subject to all other load combinations
1.63
LRFD Concrete-filled diaphragms subjected to wind, earthquake or other load combinations
1.63
1Conversion factors determined from Table D5, North American Specification for the Design of Cold-Formed Steel Structural Members, 2007 edition, (AISI S100).
Allowable strength design (ASD) diaphragm capacities in Tables 10 through 15 are for concrete-filled steel deck diaphragms subjected to earthquake loads or subjected to load combinations which include earthquake loads. For LRFD diaphragm capacities, the tabulated “q” value must be multiplied by 1.63.
4.2 Installation:
Fastener selection must be in accordance with Table 1. Figures and tables are summarized in the table of contents that appears following the text of this report. Standing seam interlocking-type sidelaps must be well engaged, and the button- punching sharp and deep. Button-punching sidelaps must be spaced at 12, 8 or 6 inches (305, 203 or 152 mm) on center for bare-steel deck diaphragms, and not more than 36 inches (914 mm) for concrete-filled steel deck diaphragms. The coating of the outer protruding nose of the punched lap should be “starred,” indicating a near-penetration of the button punching tool.
5.0 CONDITIONS OF USE
The Steel Deck and Concrete-Filled Steel Deck Diaphragms Attached with Hilti X-ENP-19 L15, X-EDN19 THQ12, or X-EDNK 22 THQ12 Fasteners described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions:
5.1 The fasteners are manufactured, identified and installed in accordance with this report, the manufacturer’s instructions and the approved plans. If there is a conflict, this report governs.
ESR-2197 | Most Widely Accepted and Trusted Page 3 of 27
5.2 Steel deck and concrete-filled steel deck diaphragm construction must comply with this report.
5.3 Allowable diaphragm shears and flexibility factors must comply with Tables 2 through 24 of this report.
5.4 Adjustment for duration of load must be limited to that described in Section 4.1.
5.5 Allowable vertical loads must be limited by the deck section properties and allowable stresses for the specific deck. Composite design values are beyond the scope of this report.
5.6 Calculations demonstrating that the applied loads do not exceed the capacities in this report must be submitted to the code official for approval. The calculations must be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed.
5.7 Steel deck diaphragms may be zoned by varying steel deck panel gage and/or connections across a diaphragm to meet varying shear and flexibility demands.
5.8 Hilti fasteners may be used for attachment of steel deck roof and floor systems temporarily exposed to the exterior during construction prior to application of a built-up roof covering system or concrete-fill. The fasteners on permanently exposed steel deck roof coverings must be covered with a corrosion-resistant paint or sealant. As an alternate to applying a corrosion-resistant paint or sealant to the X-ENP-19 L15 fasteners, these fasteners may be used in
conjunction with the SDK2 Stainless Steel Sealing Caps, described in Section 3.6 of this report, on permanently exposed steel deck roof coverings. For permanently exposed steel deck roof covering installations, the roof covering system’s compliance with Chapter 15 of the code must be justified to the satisfaction of the code official.
6.0 EVIDENCE SUBMITTED
Data in accordance with the ICC-ES Acceptance Criteria for Steel Deck Roof and Floor Systems (AC43), dated October 2010.
7.0 IDENTIFICATION
The Hilti X-ENP-19 L15, X-EDN19 THQ12 and X-EDNK22 THQ12 fasteners are identified by an “H” stamped on the fastener head. Fasteners are packaged in containers noting the fastener type, the Hilti, Inc., name and address, and the evaluation report number (ESR-2197).
8.0 OTHER CODES
In addition to the code referenced in Section 1.0, the products described in this report were evaluated for compliance with the requirements of the 2006 International Building Code® (2006 IBC). The products comply with the 2006 IBC just as described in Sections 2.0 through 7.0, except the following modifications must be made to Section 4.1:
Conversion factors in Section 4.1 of this report were determined from Table D5 in the 2004 Supplement to the North American Specification for the Design of Cold-Formed Steel Structural Members, 2001 edition.
ESR-2197 | Most Widely Accepted and Trusted Page 4 of 27
TABLE OF CONTENTS PAGE
Table 1 – Frame Fastener Selector Guide. 5
Tables 2 and 3 – Allowable diaphragm shears, q, and flexibility factors, F, for standard 11/2 inch deep, 6 inches center-to-center steel deck diaphragms installed with Hilti X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners with end and interior support fastener patterns as follows: 36/5, 36/7, 36/9 and 36/11 and screwed sidelaps. 6 and 7
Table 4 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 11/2 inch deep, 6 inches center-to-center steel deck diaphragms installed with Hilti X-ENP-19 L15 fasteners with end and interior support fastener patterns as follows: 36/7, 36/9, and 36/11 and screwed sidelaps. 8
Table 5 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 11/2 inch deep, 6 inches center-to-center steel deck diaphragms installed with Hilti X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners with end and interior support fastener patterns as follows: 36/7, 36/9, and 36/11 and button punch sidelaps. 9
Table 6 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 11/2 inch deep, 6 inches center-to-center steel deck diaphragms installed with Hilti X-ENP-19 L15 fasteners with end and interior support fastener patterns as follows: 36/7 and button punch sidelaps. 10
Table 7 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 3 inch deep, 8 inches center-to-center steel deck diaphragms installed with Hilti X-ENP-19 L15 fasteners with end and interior support fastener pattern as follows: 24/4 and screwed sidelaps. 11
Table 8 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 3 inch deep, 8 inches center-to-center steel deck diaphragms installed with Hilti X-ENP-19 L15 fasteners with end and interior support fastener pattern as follows: 24/4 and button punch sidelaps. 12
Table 9 - ASD and LRFD diaphragm capacities based on buckling of the steel deck. 13
Table 10 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 11/2 inch deep, 6 inches center-to-center steel deck with (21/2”, 31/4”, 41/2” topping thickness) lightweight structural fill installed with Hilti X-ENP-19 L15, X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners with end and interior support fastener pattern as follows: 36/4 and button punch sidelaps. 14
Table 11 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 2 and 3 inch deep, 12 inches center-to-center steel deck with (2”, 31/4”, 4” and 5” topping thickness) lightweight structural fill installed with Hilti X-ENP-19 L15, X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners with end and interior support fastener pattern as: 36/4 and button punch sidelaps. 15
Table 12 and 13 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 11/2 inch deep, 6 inches center-to-center steel deck with (21/2”, 31/2”, 41/2” and 51/2” topping thickness) normal weight structural fill installed with Hilti X-ENP-19 L15, X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners with end and interior support fastener pattern as follows: 36/4 and button punch sidelaps. 16 and 17
Table 14 and 15 - Allowable diaphragm shears, q, and flexibility factors, F, for standard 2 and 3 inch deep, 12 inches center-to-center steel deck with (2”, 3”, 4” and 5” topping thickness) normal weight structural fill installed with Hilti X-ENP-19 L15, X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners with end and interior support fastener pattern as follows: 36/4 and button punch sidelaps. 18 and 19
Table 16 – Deck types for concrete diaphragms with shear studs. 20
Table 17 and 18 – Allowable diaphragm shears and flexibility factors for normal weight and lightweight concrete fills with minimum concrete shear reinforcement. 21 and 22
Table 19 – Minimum welded wire fabric for tabulated shear values. 23
Table 20 – Typical exterior or interior shear transfer studs. 24
Table 21 – Nominal shear Qf, and Flexibility Factors, Sf, for steel deck attached with X-ENP-19 L15, X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners. 24
Table 22 – Allowable (ASD) Tension Pullout loads to resist Tension (uplift) loads for steel decks attached with X-ENP-19 L15, X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners. 24
Table 23 – Allowable (ASD) Tension Pullover loads to resist Tension (uplift) loads for steel decks attached with X-ENP-19 L15, X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners. 25
Table 24 – Diaphragm Flexibility Limitation. 27
Figure 1 – 11/2 B Deck – 36” Wide (Type A). 20
Figure 2 – 2” Deck – 36” Wide (Type B). 20
Figure 3 – 3” Deck – 36” Wide (Type C). 20
Figure 4 – Shear Studs at Supports Parallel to Flutes. 23
Figure 5 – Shear Studs at Supports Perpendicular to Flutes. 23
Figure 6 – SDK2 Stainless Steel Sealing Cap. 25
Figure 7 – Nail Head Standoff (hNVS) for X-ENP-19 L15 fasteners. 26
Figure 8 – Nail Head Standoff (hNVS) for X-EDN19 THQ12 and X-EDNK22 THQ12 fasteners. 26
ESR-2197 | Most Widely Accepted and Trusted Page 5 of 27
TABLE 1—FRAME FASTENER SELECTOR GUIDE
Base Material1,2 Fastener Type Reference Tables
Bare Steel Deck Diaphragm
Concrete Filled Diaphragm
Bar Joist or Structural Steel Shape with 1/8 in. < tf < 1/4 in.
X-EDNK22 THQ12
Tables 2, 3, 5, 9
Tables 10-15 17-18
Bar Joist or Structural Steel Shape with 3/16 in. < tf < 3/8 in.
X-EDN19 THQ12
Tables 2, 3, 5, 9
Tables 10-15 17-18
Structural Steel, Hardened Structural Steel or Heavy Bar Joist with tf > 1/4 in.
X-ENP-19 L152
Tables 4, 6, 7, 8, 9
Tables 10-15 17-18
For SI: 1 inch = 25.4 mm.
1tf = Structural framing minimum uncoated base metal thickness. Steel base material tensile strength (fu) must range from 58 to 91 ksi for all fasteners and base steel thickness combinations, except for the X-EDN19 THQ12 fastener with steel thicknesses greater than 5/16 inch. In this case, the tensile strength must range from 58 to 68 ksi. Base metal must comply with minimum strength requirements of ASTM A 36. 2Reference Figure 6 for information regarding the use of the SDK2 sealing cap.
TA
BL
E 2
—A
LL
OW
AB
LE
DIA
PH
RA
GM
SH
EA
RS
, q (
PO
UN
DS
PE
R L
INE
AL
FO
OT
) A
ND
FL
EX
IBIL
ITY
FA
CT
OR
S, F
, FO
R S
TA
ND
AR
D 1
1/2
- I
NC
H-D
EE
P F
LU
TE
S, 6
INC
HE
S C
EN
TE
R-T
O-
CE
NT
ER
ST
EE
L D
EC
K IN
ST
AL
LE
D W
ITH
HIL
TI
X-E
DN
19-T
HQ
12
OR
X-E
DN
K2
2-T
HQ
12 F
AS
TE
NE
RS
WIT
H E
ND
AN
D I
NT
ER
IOR
SU
PP
OR
T F
AS
TE
NE
R P
AT
TE
RN
S A
S F
OL
LO
WS
:
P
AT
TE
RN
36/
7
P
AT
TE
RN
36/
9
PA
TT
ER
N 3
6/11
G
AG
E
SID
EL
AP
C
ON
NE
CT
ION
F
AC
TO
R
SP
AN
(F
T –
IN.)
4’-0
” 5’
-0”
6’-0
” 7’
-0”
8’-0
” 9’
-0”
10’-
0”
PIN
S P
ER
SH
EE
T T
O S
UP
PO
RT
7 9
11
7 9
11
7 9
11
7 9
11
7 9
11
7 9
11
7 9
11
22
Scr
ews
@ 1
2" o
.c.
q
508
667
76
7
461
596
676
428
544
611
404
506
563
386
476
522
371
452
492
359
432
468
F
18.7
18
.1
17.8
16
.8
16.2
15
.9
15.6
15
.0
14.7
14
.7
14.2
13
.9
14.1
13
.5
13.3
13
.6
13.1
12
.8
13.2
12
.7
12.5
Scr
ews
@ 8
" o
.c.
q
596
748
85
6
555
684
772
526
638
713
504
603
668
488
577
634
474
555
606
464
538
584
F
18.0
17
.6
17.4
16
.0
15.6
15
.4
14.6
14
.3
14.1
13
.7
13.4
13
.2
13.0
12
.7
12.5
12
.4
12.2
12
.0
12.0
11
.7
11.6
Scr
ews
@ 6
" o
.c.
q
673
81
9 93
8 63
7 76
3 86
1 61
1 72
2 80
6 59
3 69
1 76
5 57
8 66
7 73
4 56
6 64
8 70
8 55
7 63
2 68
8
F
17.5
17
.3
17.1
15
.4
15.2
15
.1
14.1
13
.8
13.7
13
.1
12.9
12
.8
12.3
12
.1
12.0
11
.8
11.6
11
.5
11.3
11
.1
11.0
20
Scr
ews
@ 1
2" o
.c.
q
614
80
6 92
6
558
720
816
518
658
738
489
612
681
467
576
635
449
547
595
435
523
566
F
13.4
12
.9
12.6
12
.3
11.8
11
.5
11.6
11
.1
10.8
11
.1
10.6
10
.4
10.8
10
.3
10.1
10
.5
10.1
9.
8 10
.3
9.9
9.7
Scr
ews
@ 8
" o
.c.
q
721
903
1034
67
1 82
7 93
3 63
6 77
1 86
1 61
0 73
0 80
8 59
0 69
7 76
6 57
4 67
2 73
4 56
2 65
0 70
7
F
12.7
12
.4
12.2
11
.5
11.2
11
.0
10.8
10
.5
10.3
10
.2
9.9
9.8
9.8
9.5
9.4
9.5
9.2
9.1
9.2
9.0
8.9
Scr
ews
@ 6
" o
.c.
q
814
990
1133
77
0 92
2 10
41
740
873
975
717
836
926
700
807
887
686
784
857
674
765
832
F
12.3
12
.1
12.0
11
.1
10.9
10
.7
10.2
10
.0
9.9
9.6
9.5
9.4
9.2
9.0
9.0
8.9
8.7
8.6
8.6
8.5
8.4
18
Scr
ews
@ 1
2" o
.c.
q
807
1057
12
15
733
945
1071
68
2 86
4 97
0 64
4 80
4 89
5 61
5 75
7 83
7 59
2 72
0 78
9 57
3 69
0 74
7
F
8.7
8.2
8.0
8.2
7.8
7.5
8.0
7.5
7.3
7.8
7.4
7.1
7.7
7.3
7.1
7.6
7.2
7.0
7.5
7.2
7.0
Scr
ews
@ 8
" o
.c.
q
948
1186
13
58
883
1086
12
26
837
1014
11
32
803
960
1063
77
8 91
8 10
09
757
884
966
740
857
931
F
8.1
7.8
7.7
7.6
7.3
7.1
7.2
7.0
6.8
7.0
6.7
6.6
6.8
6.6
6.5
6.7
6.5
6.3
6.6
6.4
6.3
Scr
ews
@ 6
" o
.c.
q
1070
13
00
1489
10
13
1212
13
68
974
1148
12
82
944
1100
12
18
922
1062
11
68
904
1032
11
28
889
1007
10
96
F
7.7
7.5
7.4
7.2
7.0
6.9
6.8
6.6
6.5
6.5
6.4
6.3
6.3
6.2
6.1
6.2
6.0
5.9
6.0
5.9
5.8
For
SI:
1 in
ch =
25.
4 m
m, 1
foot
= 3
05 m
m, 1
plf
= 1
4.6
N/m
, 1 p
si =
6.8
9 kP
a, 1
inch
/lb =
5.7
mm
/N.
1 Ref
er t
o fo
otno
tes
on P
age
26 fo
llow
ing
Tab
le 2
3 fo
r ad
ditio
nal i
nsta
llatio
n an
d de
sign
req
uire
men
ts.
2 Allo
wab
le s
tres
s de
sign
dia
phra
gm
cap
aciti
es a
re p
rese
nted
for
dia
phra
gms
mec
hani
cally
con
nect
ed to
the
stru
ctur
e su
bjec
ted
to e
arth
quak
e lo
ads
or lo
ad c
ombi
natio
ns w
hich
in
clud
e ea
rthq
uake
load
s. D
iaph
ragm
she
ars
ma
y be
incr
ease
d fo
r ot
her
appl
icat
ions
as
pres
crib
ed in
Sec
tion
4.1
of t
his
repo
rt.
ESR-2197 | Most Widely Accepted and Trusted Page 6 of 27
ESR-2197 | Most Widely Accepted and Trusted Page 7 of 27 TABLE 3—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 11/2 - INCH-DEEP FLUTES, 6 INCHES CENTER-TO-CENTER STEEL DECK INSTALLED WITH HILTI X-EDN19-THQ12 OR X-EDNK22-THQ12 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERN AS FOLLOWS:
PATTERN 36/5
GAGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
4’-0” 5’-0” 6’-0” 7’-0” 8’-0” 9’-0” 10’-0”
PINS PER SHEET TO SUPPORT
5 5 5 5 5 5 5
22
Screws @ 12" o.c.
q 447 412 388 369 355 343 334
F 73.2 60.4 51.9 45.9 41.4 37.9 35.1
Screws @ 8" o.c.
q 511 483 464 449 437 428 420
F 72.3 59.5 50.9 44.8 40.2 36.6 33.8
Screws @ 6" o.c.
q 561 540 524 512 503 496 489
F 71.9 58.9 50.3 44.1 39.5 35.9 33.0
20
Screws @ 12" o.c.
q 540 499 469 447 429 415 404
F 47.0 39.2 34.1 30.4 27.7 25.6 23.9
Screws @ 8" o.c.
q 617 584 561 543 529 517 508
F 46.3 38.4 33.1 29.4 26.6 24.4 22.7
Screws @ 6" o.c.
q 678 652 634 619 608 599 592
F 45.8 37.9 32.6 28.8 26.0 23.8 22.0
18
Screws @ 12" o.c.
q 709 655 617 588 565 547 532
F 25.4 21.7 19.2 17.4 16.1 15.1 14.3
Screws @ 8" o.c.
q 810 768 737 714 696 681 669
F 24.8 20.9 18.4 16.5 15.2 14.1 13.3
Screws @ 6" o.c.
q 890 857 833 815 800 789 779
F 24.4 20.5 17.9 16.0 14.6 13.6 12.7
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 2Allowable stress design diaphragm capacities are presented for diaphragms mechanically connected to the structure subjected to earthquake loads or load combinations which include earthquake loads. Diaphragm shears may be increased for other applications as prescribed in Section 4.1 of this report.
TA
BL
E 4
—A
LL
OW
AB
LE
DIA
PH
RA
GM
SH
EA
RS
, q (
PO
UN
DS
PE
R L
INE
AL
FO
OT
) A
ND
FL
EX
IBIL
ITY
FA
CT
OR
S, F
, FO
R S
TA
ND
AR
D 1
1 / 2 IN
CH
-DE
EP
FL
UT
ES
, 6
INC
HE
S C
EN
TE
R-T
O-
CE
NT
ER
ST
EE
L D
EC
K IN
ST
AL
LE
D W
ITH
HIL
TI
X-E
NP
-19
L15
FA
ST
EN
ER
S W
ITH
EN
D A
ND
INT
ER
IOR
SU
PP
OR
T F
AS
TE
NE
R P
AT
TE
RN
S A
S F
OL
LO
WS
:
PA
TT
ER
N 3
6/7
PA
TT
ER
N 3
6/9
P
AT
TE
RN
36/
11
GA
GE
S
IDE
LA
P
CO
NN
EC
TIO
N
FA
CT
OR
SP
AN
(F
T –
IN.)
4’-0
” 5’
-0”
6’-0
” 7’
-0”
8’-0
” 9’
-0”
10’-
0”
PIN
S P
ER
SH
EE
T T
O S
UP
PO
RT
7 9
11
7 9
11
7 9
11
7 9
11
7 9
11
7 9
11
7 9
11
22
Scr
ews
@ 1
2" o
.c.
q
533
705
811
481
627
71
2
445
57
1 64
2
419
529
589
399
495
543
38
3 46
8 51
0
370
446
484
F
17.9
17
.4
17.2
16
.1
15.5
15
.2
14.8
14
.3
14.0
14
.0
13.4
13
.1
13.4
12
.8
12.5
12
.9
12.4
12
.1
12.6
12
.0
11.7
Scr
ews
@ 8
" o
.c.
q
623
788
902
577
717
810
545
666
745
521
628
696
503
599
658
488
575
629
476
556
604
F
17.5
17
.1
16.9
15
.5
15.1
1
4.9
14
.2
13.8
13
.6
13.3
12
.9
12.7
12
.6
12.2
12
.0
12.0
11
.7
11.5
11
.7
11.3
1
1.1
Scr
ews
@ 6
" o
.c.
q
702
861
986
662
798
901
633
753
840
612
718
795
596
692
760
583
670
732
572
653
709
F
17.2
16
.9
16.8
15
.1
14.9
14
.7
13.8
13
.5
13.4
12
.8
12.6
1
2.4
12
.1
11.
8
11.7
11
.5
11.3
11
.2
11.1
1
0.9
10
.7
20
Scr
ews
@ 1
2" o
.c.
q
644
852
980
582
757
860
539
690
776
507
639
713
483
600
565
463
566
617
448
540
586
F
12.7
12
.2
12.0
11
.6
11.1
10
.9
11.0
10
.4
10.2
10
.5
10.0
9.
7 10
.2
9.7
9.4
10.0
9.
4 9.
2 9.
8 9.
3 9.
0
Scr
ews
@ 8
" o
.c.
q
753
951
1090
69
8 86
7 97
9 65
9 80
6 90
0 63
0 76
0 84
2 60
8 72
4 79
6 59
1 69
6 76
0 57
7 67
2 73
1
F
12.3
11
.9
11.8
11
.1
10.8
10
.6
10.4
10
.0
9.8
9.8
9.5
9.3
9.4
9.1
8.9
9.2
8.8
8.7
8.9
8.6
8.5
Scr
ews
@ 6
" o
.c.
q
849
1040
11
91
801
965
1089
76
6 91
0 10
16
741
869
962
721
837
919
706
811
886
693
790
85
9
F
12.0
11
.8
11.6
10
.8
10.5
10
.4
10.0
9.
7 9.
6 9.
4 9.
2 9.
1 9.
0 8.
8 8.
6 8.
7 8.
5 8.
3 8.
4 8.
2 8.
1
18
Scr
ews
@ 1
2" o
.c.
q
846
1117
12
85
765
994
1129
70
9 90
6 10
19
667
840
937
635
790
87
4 61
0 74
9
818
590
713
77
3
F
8.1
7.6
7.4
7.6
7.2
7.0
7.4
6.9
6.7
7.3
6.8
6.6
7.2
6.7
6.5
7.1
6.6
6.4
7.1
6.6
6.4
Scr
ews
@ 8
" o
.c.
q
990
1249
14
30
918
1139
12
86
867
1059
11
83
830
999
1107
80
1 95
3 10
48
779
916
1001
76
0 88
5 96
3
F
7.7
7.4
7.3
7.2
6.9
6.8
6.9
6.6
6.4
6.7
6.4
6.2
6.5
6.2
6.1
6.4
6.1
6.0
6.3
6.1
5.9
Scr
ews
@ 6
" o
.c.
q
1116
13
66
1564
10
53
1268
14
31
1009
11
97
1336
97
6 11
43
1265
95
0 11
01
1210
93
0 10
68
1167
91
4 10
40
1131
F
7.5
7.3
7.1
6.9
6.7
6.6
6.6
6.3
6.2
6.3
6.1
6.0
6.1
5.9
5.8
6.0
5.8
5.7
5.9
5.7
5.6
For
SI:
1 in
ch =
25.
4 m
m, 1
foot
= 3
05 m
m, 1
plf
= 1
4.6
N/m
, 1 p
si =
6.8
9 kP
a, 1
inch
/lb =
5.7
mm
/N.
1 Ref
er t
o fo
otno
tes
on P
age
26 fo
llow
ing
Tab
le 2
3 fo
r ad
ditio
nal i
nsta
llatio
n an
d de
sign
req
uire
men
ts.
2 Allo
wab
le s
tres
s de
sign
dia
phra
gm
cap
aciti
es a
re p
rese
nted
for
dia
phra
gms
mec
hani
cally
con
nect
ed to
the
stru
ctur
e su
bjec
ted
to e
arth
quak
e lo
ads
or lo
ad c
ombi
natio
ns w
hich
in
clud
e ea
rthq
uake
load
s. D
iaph
ragm
she
ars
ma
y be
incr
ease
d fo
r ot
her
appl
icat
ions
as
pres
crib
ed in
Sec
tion
4.1
of t
his
repo
rt.
ESR-2197 | Most Widely Accepted and Trusted Page 8 of 27
TA
BL
E 5
—A
LL
OW
AB
LE
DIA
PH
RA
GM
SH
EA
RS
, q (
PO
UN
DS
PE
R L
INE
AL
FO
OT
) A
ND
FL
EX
IBIL
ITY
FA
CT
OR
S, F
, FO
R S
TA
ND
AR
D 1
1 / 2 -
INC
H-D
EE
P F
LU
TE
S, 6
INC
HE
S C
EN
TE
R-
TO
-CE
NT
ER
ST
EE
L D
EC
K IN
ST
AL
LE
D W
ITH
HIL
TI X
-ED
N19
-TH
Q12
OR
X-E
DN
K22
-TH
Q12
FA
ST
EN
ER
S W
ITH
EN
D A
ND
IN
TE
RIO
R S
UP
PO
RT
FA
ST
EN
ER
PA
TT
ER
NS
AS
F
OL
LO
WS
:
PA
TT
ER
N 3
6/7
PA
TT
ER
N 3
6/9
PA
TT
ER
N 3
6/11
GA
GE
S
IDE
LA
P
CO
NN
EC
TIO
N
FA
CT
OR
SP
AN
(F
T –
IN.)
5’-0
” 6’
-0”
7’-0
” 8’
-0”
9’-0
” 10
’-0”
PIN
S P
ER
SH
EE
T T
O S
UP
PO
RT
7 9
11
7 9
11
7 9
11
7 9
11
7 9
11
7 9
11
22
Bu
tto
n P
un
ch
@
12"
o.c
.
q
316
460
531
275
393
452
246
345
395
223
308
352
208
283
322
195
263
298
F
21.1
18
.7
17.8
21
.0
18.2
17
.2
21.2
18
.1
16.9
21
.6
18.2
16
.9
22.1
18
.5
17.0
22
.7
18.8
17
.3
Bu
tto
n P
un
ch
@
8"
o.c
.
q
355
496
570
317
435
493
287
386
437
265
350
394
249
324
364
237
304
340
F
20.6
18
.5
17.6
20
.3
17.9
16
.9
20.3
17
.7
16.6
20
.5
17.7
16
.5
20.8
17
.8
16.5
21
.2
18.0
16
.7
Bu
tto
n P
un
ch
@
6"
o.c
.
q
391
530
605
356
475
535
329
428
478
307
392
436
291
366
405
279
346
381
F
20.2
18
.3
17.5
19
.7
17.6
16
.7
19.6
17
.3
16.3
19
.6
17.2
16
.1
19.8
17
.2
16.1
20
.0
17.4
16
.2
20
Bu
tto
n P
un
ch
@
12"
o.c
.
q
404
575
664
355
499
570
320
441
502
293
397
450
273
363
411
258
339
382
F
16.2
14
.1
13.2
16
.5
14.0
13
.1
17.0
14
.2
13.1
17
.6
14.6
13
.3
18.2
15
.0
13.7
18
.9
15.4
14
.0
Bu
tto
n P
un
ch
@
8"
o.c
.
q
457
625
716
414
558
632
381
502
563
355
459
512
334
425
472
319
400
443
F
15.8
13
.8
13.1
15
.9
13.7
12
.8
16.2
13
.8
12.8
16
.6
14.1
13
.0
17.1
14
.4
13.2
17
.6
14.7
13
.5
Bu
tto
n P
un
ch
@
6"
o.c
.
q
509
673
767
467
609
687
437
561
625
414
520
573
396
486
534
381
462
505
F
15.4
13
.6
12.9
15
.4
13.4
12
.6
15.5
13
.5
12.6
15
.8
13.6
12
.7
16.1
13
.8
12.8
16
.5
14.1
13
.0
18
Bu
tto
n P
un
ch
@
12"
o.c
.
q
576
797
915
519
709
806
476
637
716
441
580
649
414
535
597
393
500
555
F
11.6
9.
8 9.
0 12
.2
10.1
9.
2 12
.9
10.5
9.
5 13
.6
11.0
9.
9 14
.3
11.5
10
.3
15.0
12
.0
10.7
Bu
tto
n P
un
ch
@
8"
o.c
.
q
667
882
1004
61
3 79
8 90
0 57
3 73
5 82
3 54
3 68
7 75
7 51
9 64
3 70
5 50
0 60
8 66
3
F
11.2
9.
6 8.
9 11
.7
9.8
9.0
12.2
10
.1
9.3
12.8
10
.5
9.6
13.3
10
.9
9.9
13.8
11
.4
10.3
Bu
tto
n P
un
ch
@
6"
o.c
.
q
752
963
1091
70
1 88
3 99
0 66
4 82
3 91
6 63
5 77
7 85
8 61
2 74
1 81
3 59
4 71
1 77
1
F
10.9
9.
4 8.
8 11
.2
9.6
8.9
11.6
9.
8 9.
1 12
.1
10.1
9.
3 12
.5
10.5
9.
6 12
.9
10.8
9.
9
For
SI:
1 in
ch =
25.
4 m
m, 1
foot
= 3
05 m
m, 1
plf
= 1
4.6
N/m
, 1 p
si =
6.8
9 kP
a, 1
inch
/lb =
5.7
mm
/N.
1 Ref
er t
o fo
otno
tes
on P
age
26 fo
llow
ing
Tab
le 2
3 fo
r ad
ditio
nal i
nsta
llatio
n an
d de
sign
req
uire
men
ts.
2 Allo
wab
le s
tres
s de
sign
dia
phra
gm
cap
aciti
es a
re p
rese
nted
for
dia
phra
gms
mec
hani
cally
con
nect
ed to
the
stru
ctur
e su
bjec
ted
to e
arth
quak
e lo
ads
or lo
ad c
ombi
natio
ns
whi
ch in
clud
e ea
rthq
uake
load
s. D
iaph
ragm
she
ars
ma
y be
incr
ease
d fo
r ot
her
appl
icat
ions
as
pres
crib
ed in
Sec
tion
4.1
of th
is r
epor
t.
ESR-2197 | Most Widely Accepted and Trusted Page 9 of 27
ESR-2197 | Most Widely Accepted and Trusted Page 10 of 27 TABLE 6—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 11/2-INCH-DEEP FLUTES, 6 INCHES CENTER-TO-CENTER STEEL DECK INSTALLED WITH HILTI X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERN AS FOLLOWS:
PATTERN 36/7
GAGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
5’-0” 6’-0” 7’-0” 8’-0” 9’-0” 10’-0”
PINS PER SHEET TO SUPPORT
7 7 7 7 7 7
22
Button Punch @ 12" o.c.
q 540 460 400 350 320 290
F 25.8 25.2 25.2 25.6 26.7 27.8
Button Punch @ 8" o.c.
q 567 487 427 377 347 317
F 25.5 24.9 24.3 24.9 25.4 26.4
Button Punch @ 6" o.c.
q 580 500 440 390 360 330
F 25.3 24.4 24.2 24.5 24.8 25.7
20
Button Punch @ 12" o.c.
q 640 540 470 420 380 340
F 20.6 19.8 19.6 20.0 20.7 21.4
Button Punch @ 8" o.c.
q 667 567 497 447 407 367
F 20.4 19.5 19.3 19.5 19.8 20.5
Button Punch @ 6" o.c.
q 680 580 510 460 420 380
F 20.3 19.4 19.1 19.3 19.4 20.0
18
Button Punch @ 12" o.c.
q 830 710 620 550 490 450
F 14.5 13.8 13.6 13.7 14.1 14.6
Button Punch @ 8" o.c.
q 863 737 647 599 571 547
F 14.4 13.7 13.4 10.0 10.4 10.8
Button Punch @ 6" o.c.
q 880 750 660 590 530 490
F 14.4 13.6 13.3 13.3 13.5 13.7
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 2Allowable stress design diaphragm capacities are presented for diaphragms mechanically connected to the structure subjected to earthquake loads or load combinations which include earthquake loads. Diaphragm shears may be increased for other applications as prescribed in Section 4.1 of this report.
ESR-2197 | Most Widely Accepted and Trusted Page 11 of 27 TABLE 7—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 3 - INCH-DEEP FLUTES, 8 INCHES CENTER-TO-CENTER STEEL DECK INSTALLED WITH HILTI X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERN AS FOLLOWS:
PATTERN 24/4
GAGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
7’-0” 8’-0” 9’-0” 10’-0” 11’-0” 12’-0” 13’-0” 14’-0” 15’-0”
PINS PER SHEET TO SUPPORT
4 4 4 4 4 4 4 4 4
22
Screws @ 12" o.c.
q 361 347 336 328 320 314 309 305 301
F 42.9 39.1 36.2 33.9 32.0 30.4 29.1 28.0 27.0
Screws @ 8" o.c.
q 455 443 433 426 420 414 410 406 403
F 41.5 37.6 34.6 32.2 30.2 28.6 27.2 26.0 25.0
Screws @ 6" o.c.
q 534 524 517 510 505 500 497 493 490
F 40.6 36.7 33.6 31.2 29.2 27.5 26.1 24.9 23.9
20
Screws @ 12" o.c.
q 436 420 407 397 388 381 374 369 364
F 29.1 26.9 25.2 23.8 22.7 21.7 21.0 20.3 19.7
Screws @ 8" o.c.
q 550 536 525 516 508 502 496 492 488
F 27.8 25.5 23.7 22.2 21.0 20.0 19.2 18.5 17.9
Screws @ 6" o.c.
q 646 635 625 617 611 606 601 597 594
F 27.0 24.7 22.8 21.3 20.1 19.1 18.2 17.5 16.9
18
Screws @ 12" o.c.
q 575 553 537 523 511 502 494 487 481
F 17.5 16.5 15.7 15.1 14.6 14.1 13.8 13.5 13.2
Screws @ 8" o.c.
q 725 706 692 680 670 662 655 649 643
F 16.4 15.2 14.4 13.7 13.1 12.7 12.3 11.9 11.6
Screws @ 6” o.c.
q 851 836 824 814 805 798 793 787 783
F 15.7 14.5 13.6 12.9 12.3 11.8 11.4 11.1 10.8
16
Screws @ 12" o.c.
q 721 695 674 657 642 631 621 612 604
F 12.0 11.5 11.1 10.8 10.6 10.4 10.2 10.1 10.0
Screws @ 8" o.c.
q 909 886 868 854 842 831 823 815 809
F 11.0 10.4 10.0 9.6 9.3 9.1 8.9 8.7 8.5
Screws @ 6" o.c.
q 1067 1048 1033 1021 1011 1002 995 989 983
F 10.4 9.8 9.3 8.9 8.6 8.3 8.1 7.9 7.7
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 2Allowable stress design diaphragm capacities are presented for diaphragms mechanically connected to the structure subjected to earthquake loads or load combinations which include earthquake loads. Diaphragm shears may be increased for other applications as prescribed in Section 4.1 of this report.
ESR-2197 | Most Widely Accepted and Trusted Page 12 of 27 TABLE 8—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 3 - INCH-DEEP FLUTES, 8 INCHES CENTER-TO-CENTER STEEL DECK INSTALLED WITH HILTI X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERN AS FOLLOWS:
PATTERN 24/4
GAGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
7’-0” 8’-0” 9’-0” 10’-0” 11’-0” 12’-0” 13’-0” 14’-0” 15’-0”
PINS PER SHEET TO SUPPORT
4 4 4 4 4 4 4 4 4
22
Button Punch @ 12" o.c.
q 201 186 175 166 158 152 147 142 138
F 51.5 49.1 47.6 46.6 46.0 45.7 45.7 45.7 45.9
Button Punch @ 8" o.c.
q 243 228 217 207 200 194 189 184 180
F 50.4 47.8 46.0 44.7 43.9 43.3 42.9 42.7 42.5
Button Punch @ 6" o.c.
q 284 270 258 249 242 236 230 226 222
F 49.4 46.6 44.6 43.2 43.2 41.3 40.7 40.3 39.9
20
Button Punch @ 12" o.c.
q 265 247 233 222 213 206 199 194 189
F 36.9 36.0 35.5 35.3 35.4 35.6 36.0 36.4 36.8
Button Punch @ 8" o.c.
q 326 308 295 284 275 267 261 255 251
F 35.9 34.7 34.0 33.6 33.4 33.4 33.5 33.6 33.8
Button Punch @ 6" o.c.
q 386 369 355 344 335 328 321 316 311
F 35.1 33.7 32.8 32.2 31.8 31.6 31.5 31.4 31.5
18
Button Punch @ 12" o.c.
q 401 378 360 345 334 324 315 308 302
F 24.3 24.3 24.7 25.1 25.6 26.2 26.8 27.5 28.1
Button Punch @ 8" o.c.
q 507 484 466 452 440 430 422 414 408
F 23.4 23.3 23.4 23.6 23.9 24.3 24.6 25.1 25.5
Button Punch @ 6" o.c.
q 594 573 556 543 532 522 514 507 501
F 22.7 22.4 22.3 22.4 22.5 22.7 22.9 23.2 23.4
16
Button Punch @ 12" o.c.
q 574 545 523 505 490 478 467 459 451
F 18.0 18.5 19.1 19.8 20.4 21.1 21.8 22.5 23.2
Button Punch @ 8" o.c.
q 722 696 675 658 644 632 622 613 606
F 17.3 17.6 18.0 18.4 18.9 19.4 19.9 20.4 20.9
Button Punch @ 6" o.c.
q 851 827 808 793 780 769 760 752 745
F 16.6 16.8 17.0 17.3 17.7 18.0 18.4 18.7 19.0
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 2Allowable stress design diaphragm capacities are presented for diaphragms mechanically connected to the structure subjected to earthquake loads or load combinations which include earthquake loads. Diaphragm shears may be increased for other applications as prescribed in Section 4.1 of this report.
T
AB
LE
9—
AL
LO
WA
BL
E D
IAP
HR
AG
M S
HE
AR
S, q
a (P
OU
ND
S P
ER
LIN
EA
L F
OO
T)
FO
R B
UC
KL
ING
AN
D L
RF
D D
IAP
HR
AG
M S
HE
AR
S, q
f (P
OU
ND
S P
ER
LIN
EA
L F
OO
T),
FO
R
BU
CK
LIN
G F
OR
ST
AN
DA
RD
11 / 2
–IN
CH
-DE
EP
FL
UT
ES
, 6-I
NC
HE
S C
EN
TE
R-T
O-C
EN
TE
R A
ND
ST
AN
DA
RD
3 -
IN
CH
-DE
EP
FL
UT
ES
, 8 IN
CH
ES
CE
NT
ER
-TO
-CE
NT
ER
ST
EE
L D
EC
K:
ST
EE
L D
EC
K
TY
PE
D
EC
K
GA
GE
Min
imu
m
Mo
me
nt
of
Iner
tia4
, I
in4 /f
t
SP
AN
(F
T -
IN
.)
3’-0
” 4’
-0”
5’-0
” 6’
-0”
7’-0
” 8’
-0”
9’-0
” 10
’-0”
11
’-0”
12
’-0”
AS
D, q
a
Sta
ndar
d 1
1 / 2-in
ch
Dee
p F
lute
s, 6
-In
ches
Cen
ter-
to-
Cen
ter
22
0.15
2
8,44
4
4,75
0
3,04
0
2,11
1
1,55
1
1,18
8
938
760
628
528
20
0.19
8
11,0
00
6,18
8
3,96
0
2,75
0
2,02
0
1,54
7
1,22
2
990
818
688
18
0.28
4
15,7
78
8,87
5
5,68
0
3,94
4
2,89
8
2,21
9
1,75
3
1,42
0
1,17
4
986
16
0.35
5
19,7
02
11,0
94
7,10
0
4,93
1
3,62
2
2,77
3
2,19
1
1,77
5
1,46
7
1,23
3
Sta
ndar
d 3
-Inc
h D
eep
Flu
tes,
8-
Inch
es C
ente
r-to
-C
ente
r
22
0.55
1
30,6
11
17,2
19
11,0
20
7,65
3
5,62
2
4,30
5
3,40
1
2,75
5
2,27
7
1,91
3
20
0.71
4
39,6
67
22,3
13
14,2
80
9,91
7
7,28
6
5,57
8
4,40
7
3,57
0
2,95
0
2,47
9
18
1.03
6
57,5
56
32,3
75
20,7
20
14,3
89
10,5
71
8,09
4
6,39
5
5,18
0
4,28
1
3,59
7
16
1.29
5
71,9
44
40,4
69
25,9
00
17,9
86
13,2
14
10,1
17
7,99
4
6,47
5
5,35
1
4,49
7
LR
FD
, q
f
Sta
ndar
d 1
1 / 2-in
ch
Dee
p F
lute
s, 6
-In
ches
Cen
ter-
to-
Cen
ter
22
0.15
2
13,5
11
7,60
0
4,86
4
3,37
8
2,48
2
1,90
0
1,50
1
1,21
6
1,00
5
844
20
0.19
8
17,6
00
9,90
0
6,33
6
4,40
0
3,23
3
2,47
5
1,95
6
1,58
4
1,30
9
1,10
0
18
0.28
4
25,2
44
14,2
00
9,08
8
6,31
1
4,63
7
3,55
0
2,80
5
2,27
2
1,87
8
1,57
8
16
0.35
5
31,5
56
17,7
50
11,3
60
7,88
9
5,79
6
4,43
8
3,50
6
2,84
0
2,34
7
1,97
2
Sta
ndar
d 3
-inch
D
eep
Flu
tes,
8-
Inch
es C
ente
r-to
-C
ente
r
22
0.55
1
48,9
78
27,5
50
17,6
32
12,2
44
8,99
6
6,88
8
5,44
2
4,40
8
3,64
3
3,06
1
20
0.71
4
63,4
67
35,7
00
22,8
48
15,8
67
11,6
57
8,92
5
7,05
2
5,71
2
4,72
1
3,96
7
18
1.03
6
92,0
89
51,8
00
33,1
52
23,0
22
16,9
14
12,9
50
10,2
32
8,28
8
6,85
0
5,75
6
16
1.29
5
115,
111
64
,750
41
,440
28
,778
21
,143
16
,188
12
,790
10
,360
8,
562
7,
194
For
SI:
1 in
ch =
25.
4 m
m, 1
ksi
= 6
.89
MP
a, 1
plf
= 0
.014
6 N
/mm
, 1
in4 /ft
= 1
,368
mm
4/m
m.
1 Load
val
ues
are
bas
ed u
pon
a sa
fety
fact
or (Ω
) of
2.0
0 fo
r A
SD
or
a re
sist
ance
fact
or (ϕ)
of 0
.80
for
LRF
D.
2 Dia
phra
gm s
hear
s in
this
tabl
e ar
e fo
r st
eel d
eck
buck
ling
failu
re m
ode
only
an
d a
re to
be
used
as
pres
crib
ed in
Sec
tion
4.1
of th
is r
epor
t. If
desi
gn c
ondi
tion
is n
ot ta
bula
ted,
dia
phra
gm s
hear
s fo
r bu
cklin
g m
ay
be c
alcu
late
d us
ing
the
follo
win
g eq
uatio
ns:
For
AS
D, S
buck
ling =
(I*
106 /(
lv)2
)/2.
0 ;
For
LR
FD
, Sbu
cklin
g =
(I*
106 /(
l v)2 )*
0.8
3 Dia
phra
gm r
esis
tanc
e m
ust
be li
mite
d to
less
er o
f va
lues
in t
his
ta
ble
and
the
corr
esp
ondi
ng r
espe
ctiv
e A
SD
and
LR
FD
she
ar
capa
citie
s sh
own
in T
able
s 2
thro
ugh
8 o
r ca
lcul
ated
per
Sec
tion
4.1
of th
is r
epor
t.
4 The
tab
ulat
ed m
omen
t of i
nert
ia,
I, is
the
requ
ired
gros
s m
omen
t of
iner
tia o
f the
ste
el d
eck
pane
ls a
bout
the
horiz
onta
l neu
tral
axi
s of
the
pan
el c
ross
sec
tion
.
ESR-2197 | Most Widely Accepted and Trusted Page 13 of 27
ESR-2197 | Most Widely Accepted and Trusted Page 14 of 27 TABLE 10—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 1-1/2- INCH-DEEP FLUTES, 6 INCHES CENTER-TO-CENTER STEEL DECK WITH STRUCTURAL CONCRETE FILL INSTALLED WITH HILTI X-EDN19-THQ12, X-EDNK22-THQ12 OR X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERNS AS FOLLOWS:
PATTERN 36/4
dc
f ’c
FILL TYPE
GAGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
6’-0” 7’-0” 8’-0” 9’-0” 10’-0” 11’-0” 12’-0” 13’-0” 14’-0”
PINS PER SHEET TO SUPPORT
4 4 4 4 4 4 4 4 4
21/2” 3,000 psi Structural
Sand Light
Weight Concrete
22 Button Punch
@ 36” o.c.
q 1132 1115 1103 1094 1086 1080 1075 1071 1067
F 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.42
20 Button Punch
@ 36” o.c.
q 1165 1146 1131 1120 1110 1103 1097 1091 1087
F 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41
18 Button Punch
@ 36” o.c.
q 1231 1205 1186 1171 1159 1150 1142 1134 1129
F 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41
16 Button Punch
@ 36” o.c.
q 1307 1276 1252 1233 1219 1206 1196 1188 1181
F 0.40 0.40 0.40 0.40 0.40 0.41 0.41 0.41 0.41
31/4” 3,000 psi Structural
Sand Light
Weight Concrete
22 Button Punch
@ 36” o.c.
q 1520 1504 1492 1482 1475 1469 1464 1459 1455
F 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
20 Button Punch
@ 36” o.c.
q 1554 1534 1519 1508 1499 1492 1485 1480 1476
F 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
18 Button Punch
@ 36” o.c.
q 1619 1594 1575 1560 1548 1538 1530 1523 1517
F 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
16 Button Punch
@ 36” o.c.
q 1696 1664 1640 1622 1607 1595 1585 1576 1569
F 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31
41/2” 3,000 psi Structural
Sand Light
Weight Concrete
22 Button Punch
@ 36” o.c.
q 1929 1913 1901 1892 1884 1883 1873 1869 1865
F 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
20 Button Punch
@ 36” o.c.
q 1963 1943 1929 1917 1908 1901 1894 1990 1884
F 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
18 Button Punch
@ 36” o.c.
q 2028 2003 1984 1969 1957 1947 1939 1914 1908
F 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
16 Button Punch
@ 36” o.c.
q 2105 2073 2058 2031 2016 2004 1994 1965 1957
F 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Concrete cover depth as indicated in table above. 2Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 3See Table 1 for required base steel thickness ranges for each fastener. 4Steel deck and reinforcement must comply with Section 3.2 and 3.4, respectively. 5Allowable stress design diaphragm shears are presented. Diaphragm shears may be increased for LRFD by multiplying the tabulated “q” value by 1.63.
ESR-2197 | Most Widely Accepted and Trusted Page 15 of 27 TABLE 11— ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 2 – AND 3-INCH-DEEP FLUTES, 12 INCHES CENTER-TO-CENTER STEEL DECK WITH STRUCTURAL CONCRETE FILL INSTALLED WITH HILTI, X-EDN19-THQ12, X-EDNK22-THQ12 OR X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERN AS FOLLOWS:
PATTERN 36/4
dc
f ’c
FILL TYPE GAGE
SIDELAP CONNECTION
FACTOR
SPAN (FT – IN.)
6’-0” 7’-0” 8’-0” 9’-0” 10’-0” 11’-0” 12’-0” 13’-0” 14’-0”
PINS PER SHEET TO SUPPORT
4 4 4 4 4 4 4 4 4
2” 3,000 psi Structural Sand Light
Weight Concrete
20 Button Punch
@ 36” o.c.
q 952 934 921 911 903 896 891 886 882
F 0.51 0.51 0.51 0.51 0.51 0.51 0.52 0.52 0.52
19 Button Punch
@ 36” o.c.
q 983 963 948 936 926 918 912 906 902
F 0.51 0.51 0.51 0.51 0.51 0.51 0.51 0.51 0.51
18 Button Punch
@ 36” o.c.
q 1014 991 973 960 949 941 933 927 922
F 0.50 0.51 0.51 0.51 0.51 0.51 0.51 0.51 0.51
16 Button Punch
@ 36” o.c.
q 1086 1057 1036 1019 1006 995 986 978 972
F 0.50 0.50 0.50 0.50 0.51 0.51 0.51 0.51 0.51
31/4” 3,000 psi Structural Sand Light
Weight Concrete
20 Button Punch
@ 36” o.c.
q 1541 1523 1510 1499 1491 1484 1479 1474 1470
F 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
19 Button Punch
@ 36” o.c.
q 1572 1551 1536 1524 1515 1507 1500 1495 1490
F 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
18 Button Punch
@ 36” o.c.
q 1602 1579 1562 1549 1538 1529 1522 1515 1510
F 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
16 Button Punch
@ 36” o.c.
q 1675 1646 1624 1608 1594 1583 1574 1566 1560
F 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31
4” 3,000 psi Structural Sand Light
Weight Concrete
20 Button Punch
@ 36” o.c.
q 1750 1732 1719 1709 1700 1694 1688 1683 1680
F 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26
19 Button Punch
@ 36” o.c.
q 1781 1760 1745 1733 1723 1716 1710 1704 1699
F 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26
18 Button Punch
@ 36” o.c.
q 1811 1788 1771 1758 1747 1738 1731 1724 1719
F 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26
16 Button Punch
@ 36” o.c.
q 1883 1855 1833 1817 1804 1792 1783 1776 1769
F 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26
5” 3,000 psi Structural Sand Light
Weight Concrete
20 Button Punch
@ 36” o.c.
q 2148 2131 2118 2108 2099 2093 2087 2082 2079
F 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21
19 Button Punch
@ 36” o.c.
q 2180 2159 2144 2132 2122 2115 2108 2103 2098
F 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21
18 Button Punch
@ 36” o.c.
q 2210 2187 2170 2157 2146 2137 2130 2133 2118
F 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21
16 Button Punch
@ 36” o.c.
q 2282 2254 2232 2215 2202 2191 2182 2175 2168
F 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Concrete cover depth as indicated in table above. 2Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 3See Table 1 for required base steel thickness ranges for each fastener. 4Steel deck and reinforcement must comply with Section 3.2 and 3.4, respectively. 5Allowable stress design diaphragm shears are presented. Diaphragm shears may be increased for LRFD by multiplying the tabulated “q” value by 1.63.
ESR-2197 | Most Widely Accepted and Trusted Page 16 of 27 TABLE 12—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 1-1/2- INCH-DEEP FLUTES, 6 INCHES CENTER-TO-CENTER STEEL DECK WITH STRUCTURAL CONCRETE FILL INSTALLED WITH HILTI X-EDN19-THQ12, X-EDNK22-THQ12 OR X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERNS AS FOLLOWS:
PATTERN 36/4
dc
f ’c
FILL TYPE
GAUGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
6’-0” 7’-0” 8’-0” 9’-0” 10’-0” 11’-0” 12’-0” 13’-0” 14’-0”
PINS PER SHEET TO SUPPORT
4 4 4 4 4 4 4 4 4
21/2” 3,000 psi Normal Weight
Concrete
22 Button Punch
@ 36” o.c.
q 1644 1627 1615 1618 1598 1592 1587 1583 1579
F 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.42
20 Button Punch
@ 36” o.c.
q 1677 1657 1643 1631 1622 1615 1609 1603 1599
F 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41
18 Button Punch
@ 36” o.c.
q 1743 1717 1698 1683 1671 1662 1654 1646 1641
F 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41
16 Button Punch
@ 36” o.c.
q 1819 1788 1764 1745 1731 1718 1708 1700 1693
F 0.40 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41
31/2” 3,000 psi Normal Weight
Concrete
22 Button Punch
@ 36” o.c.
q 2247 2231 2219 2209 2202 2196 2191 2187 2182
F 0.29 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30
20 Button Punch
@ 36” o.c.
q 2281 2261 2246 2235 2226 2218 2212 2207 2203
F 0.29 0.29 0.30 0.30 0.30 0.30 0.30 0.30 0.30
18 Button Punch
@ 36” o.c.
q 2346 2321 2302 2287 2275 2265 2257 2250 2244
F 0.29 0.29 0.29 0.30 0.30 0.30 0.30 0.30 0.30
16 Button Punch
@ 36” o.c.
q 2423 2391 2367 2349 2334 2322 2312 2303 2296
F 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.30 0.30
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Concrete cover depth as indicated in table above. 2Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 3See Table 1 for required base steel thickness ranges for each fastener. 4Steel deck and reinforcement must comply with Section 3.2 and 3.4, respectively. 5Allowable stress design diaphragm shears are presented. Diaphragm shears may be increased for LRFD by multiplying the tabulated “q” value by 1.63.
ESR-2197 | Most Widely Accepted and Trusted Page 17 of 27 TABLE 13—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 1-1/2- INCH-DEEP FLUTES, 6 INCHES CENTER-TO-CENTER STEEL DECK WITH STRUCTURAL CONCRETE FILL INSTALLED WITH HILTI X-EDN19-THQ12, X-EDNK22-THQ12, OR X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERNS AS FOLLOWS:
PATTERN 36/4
dc
f ’c
FILL TYPE
GAGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
6’-0” 7’-0” 8’-0” 9’-0” 10’-0” 11’-0” 12’-0” 13’-0” 14’-0”
PINS PER SHEET TO SUPPORT
4 4 4 4 4 4 4 4 4
41/2” 3,000 psi Normal Weight
Concrete
22 Button Punch
@ 36” o.c.
q 2851 2835 2822 2813 2805 2799 2794 2790 2786
F 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
20 Button Punch
@ 36” o.c.
q 2884 2865 2850 2839 2829 2822 2816 2811 2806
F 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
18 Button Punch
@ 36” o.c.
q 2950 2925 2905 2890 2879 2869 2861 2853 2848
F 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
16 Button Punch
@ 36” o.c.
q 3026 2995 2971 2952 2938 2925 2915 2907 2900
F 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
51/2” 3,000 psi Normal Weight
Concrete
22 Button Punch
@ 36” o.c.
q 3454 3438 3426 3417 3409 3403 3398 3394 3390
F 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19
20 Button Punch
@ 36” o.c.
q 3488 3468 3454 3442 3433 3426 3420 3414 3410
F 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19
18 Button Punch
@ 36” o.c.
q 3554 3528 3509 3494 3482 3472 3464 3457 3452
F 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19
16 Button Punch
@ 36” o.c.
q 3630 3598 3574 3556 3541 3529 3519 3511 3503
F 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19 0.19
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Concrete cover depth as indicated in table above. 2Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 3See Table 1 for required base steel thickness ranges for each fastener. 4Steel deck and reinforcement must comply with Section 3.2 and 3.4, respectively. 5Allowable stress design diaphragm shears are presented. Diaphragm shears may be increased for LRFD by multiplying the tabulated “q” value by 1.63.
ESR-2197 | Most Widely Accepted and Trusted Page 18 of 27 TABLE 14—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 2 - INCH-DEEP FLUTES, 12 INCHES CENTER-TO-CENTER STEEL DECK WITH STRUCTURAL CONCRETE FILL INSTALLED WITH HILTI X-EDN19-THQ12, X-EDNK22-THQ12 OR X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERN AS FOLLOWS:
PATTERN 36/4
dc
f ’c
FILL TYPE
GAGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
6’-0” 7’-0” 8’-0” 9’-0” 10’-0” 11’-0” 12’-0” 13’-0” 14’-0”
PINS PER SHEET TO SUPPORT
4 4 4 4 4 4 4 4 4
2” 3,000 psi Normal Weight
Concrete
20 Button Punch
@ 36” o.c.
q 1361 1344 1331 1321 1312 1306 1300 1295 1292
F 0.51 0.51 0.51 0.51 0.51 0.51 0.52 0.52 0.52
19 Button Punch
@ 36” o.c.
q 1393 1372 1357 1345 1335 1328 1321 1316 1311
F 0.51 0.51 0.51 0.51 0.51 0.51 0.51 0.51 0.52
18 Button Punch
@ 36” o.c.
q 1423 1400 1383 1370 1359 1350 1343 1336 1331
F 0.50 0.50 0.50 0.50 0.51 0.51 0.51 0.51 0.52
16 Button Punch
@ 36” o.c.
q 1495 1467 1445 1429 1415 1404 1395 1388 1381
F 0.50 0.50 0.50 0.50 0.51 0.51 0.51 0.51 0.51
3” 3,000 psi Normal Weight
Concrete
20 Button Punch
@ 36” o.c.
q 1965 1948 1934 1924 1916 1909 1904 1899 1895
F 0.34 0.34 0.34 0.34 0.35 0.35 0.35 0.35 0.35
19 Button Punch
@ 36” o.c.
q 1996 1976 1961 1949 1928 1931 1925 1919 1915
F 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34
18 Button Punch
@ 36” o.c.
q 2027 2004 1986 1973 1949 1954 1946 1940 1935
F 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34
16 Button Punch
@ 36” o.c.
q 2099 2070 2058 2032 2000 2008 1999 1991 1985
F 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Concrete cover depth as indicated in table above. 2Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 3See Table 1 for required base steel thickness ranges for each fastener. 4Steel deck and reinforcement must comply with Section 3.2 and 3.4, respectively. 5Allowable stress design diaphragm shears are presented. Diaphragm shears may be increased for LRFD by multiplying the tabulated “q” value by 1.63.
ESR-2197 | Most Widely Accepted and Trusted Page 19 of 27 TABLE 15—ALLOWABLE DIAPHRAGM SHEARS, q (POUNDS PER LINEAL FOOT) AND FLEXIBILITY FACTORS, F, FOR STANDARD 2 – AND 3-INCH-DEEP FLUTES, 12 INCHES CENTER-TO-CENTER STEEL DECK WITH STRUCTURAL CONCRETE FILL INSTALLED WITH HILTI X-EDN19-THQ12, X-EDNK22-THQ12 OR X-ENP-19 L15 FASTENERS WITH END AND INTERIOR SUPPORT FASTENER PATTERN AS FOLLOWS:
PATTERN 36/4
dc
f ’c
FILL TYPE
GAGE SIDELAP
CONNECTION FACTOR
SPAN (FT – IN.)
6’-0” 7’-0” 8’-0” 9’-0” 10’-0” 11’-0” 12’-0” 13’-0” 14’-0”
PINS PER SHEET TO SUPPORT
4 4 4 4 4 4 4 4 4
4” 3,000 psi Normal Weight
Concrete
20 Button Punch
@ 36” o.c.
q 2569 2551 2538 2528 2519 2513 2507 2502 2499
F 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26
19 Button Punch
@ 36” o.c.
q 2600 2579 2564 2552 2543 2535 2529 2523 2519
F 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26
18 Button Punch
@ 36” o.c.
q 2630 2607 2590 2577 2566 2557 2550 2544 2538
F 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26
16 Button Punch
@ 36” o.c.
q 2702 2674 2652 2636 2623 2611 2602 2601 2588
F 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26
5” 3,000 psi Normal Weight
Concrete
20 Button Punch
@ 36” o.c.
q 3172 3155 3142 3131 3123 3116 3111 3106 3102
F 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21
19 Button Punch
@ 36” o.c.
q 3203 3183 3168 3156 3146 3139 3132 3126 3122
F 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21
18 Button Punch
@ 36” o.c.
q 3234 3211 3194 3180 3170 3161 3154 3147 3142
F 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21
16 Button Punch
@ 36” o.c.
q 3296 3269 3249 3233 3220 3187 3194 3194 3188
F 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21
For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1inch/lb = 5.7 mm/N.
1Concrete cover depth as indicated in table above. 2Refer to footnotes on Page 26 following Table 23 for additional installation and design requirements. 3See Table 1 for required base steel thickness ranges for each fastener. 4Steel deck and reinforcement must comply with Section 3.2 and 3.4, respectively. 5Allowable stress design diaphragm shears are presented. Diaphragm shears may be increased for LRFD by multiplying the tabulated “q” value by 1.63.
ESR-2197 | Most Widely Accepted and Trusted Page 20 of 27
TABLE 16—DECK TYPES FOR CONCRETE FILLED DIAPHRAGMS WITH SHEAR CONNECTORS
DECK TYPES TABLE TYPES GAGE FIGURE
11/2” deep B deck – 36” wide Type A 22, 20, 18, 16 Figure 1
2” deep – 36” wide Type B 20, 19, 18, 16 Figure 2
3” deep – 36” wide Type C 20, 19, 18, 16 Figure 3
For SI: 1 inch = 25.4 mm, 1 psi = 6.89 kPa.
Notes: 1.) Steel shall conform to ASTM A653, Structural Steel (SS) Grade 33 with minimum Fy = 33,000 psi (230000 kPa). 2.) Galvanizing shall be minimum G60 designation. Deck may be painted or phosphatized. 3.) Refer to notes following Tables 17 and 18.
For SI: 1 inch = 25.4 mm
FIGURE 1—11/2” B DECK – 36” WIDE (TYPE A)
For SI: 1 inch- 25.4 mm
FIGURE 2—2” DECK – 36” WIDE (TYPE B)
For SI: 1 inch = 25.4 mm
FIGURE 3—3” DECK – 36” WIDE (TYPE C)
ESR-2197 | Most Widely Accepted and Trusted Page 21 of 27
TABLE 17—ALLOWABLE DIAPHRAGM SHEARS AND FLEXIBILITY FACTORS WITH MINIMUM CONCRETE SHEAR REINFORCEMENT OF 0.00075 bW S2
1, 2, 3, 4, 5, 11
CONCRETE TYPES 6, 7
CONCRETE THICKNESS 8
ALLOWABLE DIAPHRAGM SHEAR (lb/ft)
F 10 Minimum Average Spacing of Shear Studs9
12” 18” 24” 30” 36”
NW
2” 1600 1600 1600 1600 1600 0.42
21/2” 2000 2000 2000 2000 2000 0.33
3” 2390 2390 2390 2390 2270 0.28
31/2” 2790 2790 2790 2720 2270 0.24
4” 3190 3190 3190 2720 2270 0.21
41/2” 3590 3590 3400 2720 2270 0.18
5” 3990 3990 3400 2720 2270 0.17
51/2” 4390 4390 3400 2720 2270 0.15
LW
2” 1360 1360 1360 1360 1360 0.63
21/2” 1700 1700 1700 1700 1700 0.50
3” 2030 2030 2030 2030 1880 0.42
31/4” 2200 2200 2200 2200 1880 0.38
31/2” 2370 2370 2370 2260 1880 0.36
4” 2710 2710 2710 2260 1880 0.31
41/2” 3050 3050 2820 2260 1880 0.28
5” 3390 3390 2820 2260 1880 0.25
51/2” 3730 3730 2820 2260 1880 0.23
For SI: 1 inch = 25.4 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1 psf = 16 kg/m3, 1 in2/foot = 2,117 mm2/m, 1 pcf = 16.018 kg/m3.
1The allowable diaphragm shear values in Table 17 (in pounds per foot) are based on concrete slab reinforcement with an area equal to 0.00075 (less than 0.0025) times the area of fill above the top flute of the deck, but not less than 0.028 sq. in. per foot width (ASCE 3-91, Section 2.3.3.1). The common welded wire fabric of the sized listed in Table 19 meets this requirement. 2See details in Figures 1 – 3 for qualified deck types with location of minimum number of Hilti fasteners to supports perpendicular to flutes. 3Standing seam sidelaps of deck shall be fastened by button punches at 36” o.c. 4For local shear transfer within the field of the diaphragm, 1/2” minimum diameter studs having shear values of 6.8 kips per stud for normal weight concrete and 5.6 kips per stud for structural sand lightweight concrete, except as noted hereafter shall be used. For Deck Type A (11/2” deep B deck – 36” wide) if the width of concrete at the stud is less than 2.25 inches, values for 5.7 kips per stud for normal weight concrete fills and 4.7 kips per stud for structural sand lightweight concrete fills shall be used. 5bw = web width, in. s2 = spacing of shear reinforcement in direction perpendicular to longitudinal reinforcement, in. 6Concrete fill shall have a f ’c = 3,000 psi minimum with either normal weight aggregate conforming to ASTM C 33 or lightweight coarse aggregate conforming to ASTM C 330. 7NW = Normal Weight (145 pcf) LW = Lightweight (110+/- pcf) 8The concrete thickness is measured from the top flute of steel deck. 9 Deck Types A and B ( 11/2” deep, B deck – 36” wide and 2” deep – 36” wide respectively) must use 1/2” minimum diameter Type B studs. Deck Type C (3” deep – 36” wide) must use 5/8” minimum diameter Type B studs. 10F = Flexibility Factor (Deflection in micro-inches of a one foot element under a shear of 1 pound per foot). 11Refer to notes on Page 26 following Table 23 for additional installation and design requirements.
ESR-2197 | Most Widely Accepted and Trusted Page 22 of 27
TABLE 18—ALLOWABLE DIAPHRAGM SHEARS AND FLEXIBILITY FACTORS WITH MINIMUM CONCRETE SHEAR REINFORCEMENT OF 0.0025 bW S2
1, 2, 3, 4, 5, 11
CONCRETE TYPES 6, 7
CONCRETE THICKNESS8
ALLOWABLE DIAPHRAGM SHEAR (lb/ft)
F 10 Minimum Average Spacing of Shear Studs 9
12” 18” 24” 30” 36”
NW
2” 3780 3780 3400 2720 2270 0.42
21/2” 4730 4530 3400 2720 2270 0.33
3” 5670 4530 3400 2720 2270 0.28
31/2” 6620 4530 3400 2720 2270 0.24
4” 6800 4530 3400 2720 2270 0.21
41/2” 6800 4530 3400 2720 2270 0.18
5” 6800 4530 3400 2720 2270 0.17
51/2” 6800 4530 3400 2720 2270 0.15
LW
2” 3540 3540 2820 2260 1880 0.63
21/2” 4430 3760 2820 2260 1880 0.50
3” 5310 3760 2820 2260 1880 0.42
31/4” 5640 3760 2820 2260 1880 0.38
31/2” 5640 3760 2820 2260 1880 0.36
4” 5640 3760 2820 2260 1880 0.31
41/2” 5640 3760 2820 2260 1880 0.28
5” 5640 3760 2820 2260 1880 0.25
51/2” 5640 3760 2820 2260 1880 0.23
For SI: 1 inch = 25.4 mm, 1 plf = 14.6 N/m, 1 psi = 6.89 kPa, 1 psf = 16 kg/m3, 1 in2/foot = 2,117 mm2/m, 1 pcf = 16.018 kg/m3.
1The allowable diaphragm shear values in Table 18 (in pounds per foot) are based on concrete slab reinforcement with an area equal to 0.0025 times the area of fill above the top flute of the deck but not less than 0.028 sq. in. per foot width (ASCE 3-91, Section 2.3.3.1). The common welded wire fabric of the size listed in Table 19 meets this requirement. 2See details in Figures 1 – 3 for qualified deck types with location of minimum number of Hilti fasteners to supports perpendicular to flutes. 3Standing seam sidelaps of deck shall be fastened by button punches at 36” o.c. 4For local shear transfer within the field of the diaphragm, 1/2” minimum diameter studs having shear values of 6.8 kips per stud for normal weight concrete and 5.6 kips per stud for structural sand lightweight concrete, except as noted hereafter shall be used. For Deck Type A (11/2” deep B deck – 36” wide) if the width of concrete at the stud is less than 2.25 inches, values for 5.7 kips per stud for normal weight concrete fills and 4.7 kips per stud for structural sand lightweight concrete fills shall be used. 5bw = web width, in. s2 = spacing of shear reinforcement in direction perpendicular to longitudinal reinforcement, in. 6Concrete fill shall have a f ’c = 3,000 psi minimum with either normal weight aggregate conforming to ASTM C 33 or lightweight coarse aggregate conforming to ASTM C 330. 7NW = Normal Weight (145 pcf) LW = Lightweight (110+/- pcf) 8The concrete thickness is measured from the top flute of steel deck. 9Deck Types A and B (11/2” deep, B deck – 36” wide and 2” deep – 36” wide respectively) must use 1/2” minimum diameter Type B studs. Deck Type C (3” deep – 36” wide) must use 5/8” minimum diameter Type B studs. 10F = Flexibility Factor (Deflection in micro-inches of a one foot element under a shear of 1 pound per foot). 11Refer to notes on Page 26 following Table 23 for additional installation and design requirements.
ESR-2197 | Most Widely Accepted and Trusted Page 23 of 27
TABLE 19—MINIMUM WELDED WIRE REINFORCEMENT FOR TABULATED SHEAR VALUES
TABLE NO. CONCRETE THICKNESS ( 1 ) MINIMUM WELDED WIRE FABRIC FOR TABULATED SHEAR VALUES
Table 17 (0.00075 bw s2 )
2” to 3” 6 x 6 – W1.4 x W1.4
31/4” to 4” 6 x 6 – W2.0 x W2.0
41/2” to 51/2” 6 x 6 – W2.9 x W2.9
Table 18 (0.0025 bw s2)
2” to 21/2” 6 x 6 – W4.0 x W4.0
3” to 4” 4 x 4 – W4.0 x W4.0
41/2” to 5” 6 x 6 – W7.5 x W7.5
51/2” 6 x 6 – W8.3 x W8.3
For SI: 1 inch = 25.4 mm.
1The concrete thickness is measured from the top flute of steel deck.
For SI: 1 inch = 25.4 mm
FIGURE 4—SHEAR STUDS AT SUPPORTS PARALLEL TO FLUTES
For SI: 1 inch = 25.4 mm
FIGURE 5—SHEAR STUDS AT SUPPORTS PERPENDICULAR TO FLUTES
17 & 18
TABLES 17 & 18 FOOTNOTE 4
ESR-2197 | Most Widely Accepted and Trusted Page 24 of 27
TABLE 20—TYPICAL EXTERIOR OR INTERIOR SHEAR TRANSFER STUDS
t d MINIMUM STUD LENGTH ls
11/2” 3”
2” 31/2”
3” 41/2”
For SI: 1 inch = 25.4 mm.
Refer to notes on Page 26 following Table 23.
TABLE 21—NOMINAL SHEAR, Qf (LBS), AND FLEXIBILITY FACTORS, Sf (IN./KIP), FOR X-ENP-19 L15, X-EDN19-THQ12 OR X-EDNK22-THQ12 FASTENERS ATTACHING STEEL DECK TO STEEL SUPPORTS1
FASTENER FACTOR
PANEL THICKNESS (IN.)
0.0598 (16 GAGE)
0.0474 (18 GAGE)
0.0418 (19 GAGE)
0.0358 (20 GAGE)
0.0295 (22 GAGE)
X-ENP-19 L15 Qf 3149 2529 2243 1933 1603
Sf 0.0044 0.0040 0.0037 0.0034 0.0031
X-EDN19-THQ12 Qf 2924 2348 2083 1795 1489
Sf 0.0051 0.0057 0.0061 0.0066 0.0073
X-EDNK22-THQ12 Qf 2924 2348 2083 1795 1489
Sf 0.0051 0.0057 0.0061 0.0066 0.0073
For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N, 1 inch/kip = 5.7 mm/kN.
1Refer to notes following Table 23 for additional installation and design requirements.
TABLE 22—ALLOWABLE (ASD) TENSION PULLOUT LOADS TO RESIST TENSION (UPLIFT) LOADS FOR STEEL DECK PANELS ATTACHED WITH X-EDNK22 THQ12, X-EDN19 THQ12 OR X-ENP-19 L15FASTENERS (pounds) 1, 2
FASTENER BASE MATERIAL THICKNESS, in.
1/8 3/16
1/4 5/16
3/8 1/2
3 ≥ 5/8 4
ASTM A 36 (Fy = 36 ksi, Fu = 58 ksi)
X-EDNK22 THQ12 435 520 520 - - - -
X-EDN19 THQ12 - 340 440 540 540 - -
X-ENP-19 L15 - - 905 1,010 1,125 1,010 965
ASTM A 572 or A 992 Grade 50 (Fy = 50 ksi, Fu = 65 ksi)
X-EDNK22 THQ12 445 560 560 - - - -
X-EDN19 THQ12 - 340 475 575 585 - -
X-ENP-19 L15 - - 975 1,090 1,205 1,090 1,040
For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N, 1 ksi = 6.89 MPa.
1Tabulated allowable (ASD) values based upon a safety factor (Ω) of 5.0. To obtain LRFD pullout capacities, the tabulated values must be multiplied by 1.6. 2Unless otherwise noted, the tabulated pullout values are based on minimum penetration of fasteners of 9/16-inch for the X-EDNK22 and X-ENP-19 fasteners and 1/2-inch for the X-EDN19 fastener. 3Tabulated pullout capacities in 1/2-inch steel based upon a minimum point penetration of 1/2-inch. If 1/2-inch point penetration is not achieved, but a point penetration of at least 3/8-inch is obtained, the tabulated value must be multiplied by a factor of 0.63. 4Tabulated pullout capacities in greater than or equal to 5/8-inch steel based upon a minimum point penetration of 1/2-inch. If 1/2-inch point penetration is not achieved, but a point penetration of at least 3/8-inch is obtained, the tabulated value must be multiplied by a factor of 0.82.
ESR-2197 | Most Widely Accepted and Trusted Page 25 of 27
TABLE 23—ALLOWABLE TENSION PULLOVER LOADS TO RESIST TENSION (UPLIFT) LOADS FOR STEEL DECK PANELS ATTACHED WITH X-EDNK22 THQ12, X-EDN19 THQ12 OR X-ENP-19 L15 FASTENERS (pounds) 1, 2
FASTENER BASE STEEL THICKNESS,
in.
DECK GAGE (in.)
No. 22 (0.0295)
No. 20 (0.0358)
No. 18 (0.0474)
No. 16 (0.0598)
X-EDNK22-THQ12 1/8 ≤ tf ≤ 1/4 315 380 505 640
X-EDN19-THQ12 3/16 ≤ tf ≤ 3/8 315 380 505 640
X-ENP-19 L15 ≥ 1/4 660 705 805 880
For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N.
1Tabulated allowable (ASD) values are based upon a safety factor (Ω) of 3.0. To obtain LRFD pullout capacities, the tabulated values must be multiplied by 1.6. 2Based upon minimum ASTM A 653 SS Grade 33 (fy = 33 ksi, fu = 45 ksi) steel deck.
Note: To be used with X-ENP-19 L15 fasteners. X-ENP-19 Nailhead standoff (hNVS) must be as shown in Figure 7
FIGURE 6—SDK2 SEALING CAP
ESR-2197 | Most Widely Accepted and Trusted Page 26 of 27
FOOTNOTES TO TABLES 2 THROUGH 23
1. Hilti X-ENP-19 L15, X-EDN19 THQ12 or X-EDNK22 THQ12 fasteners are used at all panel ends, interior supports and deck edges parallel to the deck corrugations. The sides of adjacent panels parallel to the corrugations are lapped by nesting or interlocking and then fastened with a minimum No. 10 self-drilling steel screws as described in Section 3.7 or button punched.
2. Evenly spaced seam connectors per span length excluding those at supports.
3. The following assumptions apply to the attached tables: a. The deck sheet length is assumed to equal the span
times the number of spans. b. All tables are based on a three span condition. c. For steel deck diaphragms in Tables 2 - 8, the number
of diaphragm edge fasteners at walls or transfer zones parallel to the deck corrugations is assumed to equal the same number of stitch or sidelap connectors at interior sidelaps.
d. For concrete filled diaphragms in Tables 10 – 15, the number of edge fasteners at walls or transfer zones parallel to the deck corrugations shall not exceed 30 inches (762 mm) on center.
4. Tables 2 – 6, 10, and 12 - 13 apply to intermediate and wide rib 1-1/2-inch (38 mm) deep metal deck with a flute pitch of 6 inches provided adequate space is available for fastener placement.
5. Tables 7 - 8, 11 and 14 – 15 apply to 2-inch and 3-inch deep metal decking with flute pitch of 12 inches, provided adequate space is available for fastener placement.
6. For Tables 10-15, No.10 screws or larger may be substituted for the specified button punches.
7. The embedment of Hilti fasteners into the structural support member is such that the standoff dimension, hNVS in Figures 7 – 8 is obtained.
8. Hilti fasteners shall be centered not less than 1 inch (25 mm) from the panel ends and not less than 5/16 inch (7.9 mm) from the panel edges parallel to corrugations at the sidelaps.
9. Diaphragm deflections must be considered in the design. Table 24 describes diaphragm limitations. a. Flexibility Factor F is defined as the average micro-
inches a diaphragm web will deflect in a span of one foot under a shear load of one pound per foot. F = 1000/G', micro-inches/pound (μm/N)
b. The general deflection equation is: d2y = M / EI + q / B G’ d x2 For a uniformly loaded rectangular diaphragm on a simple span, the maximum deflection at the centerline of the diaphragm is: ∆ = 5(1728)qL4 / 384 EI + qLF/ 106
(For SI: 5(1000)4 qL4 / 384 EI + qLF/106)
∆ = Diaphragm deflection, inches (mm).
q = Wind or seismic load, kips per lineal foot (N/m)
qave = Average shear in diaphragm in pounds per foot (N/m) over length L.
L = Length of diaphragm normal to load, feet (m).
B = Width of diaphragm parallel to load, feet (m).
E = Modulus of elasticity of supporting steel chord material, pounds per square inch (kPa).
I = Moment of inertia, inches4 (mm4). Diaphragm deflection equations provided apply to rectangular symmetrical diaphragms only. Nonrectangular diaphragms, nonsymmetrical diaphragms with re-entrant corners or diaphragms subjected to torsional loadings require special design considerations.
c. Roof diaphragms supporting masonry or concrete walls shall have their deflections limited to the following: ∆ = H2 fc / 0.01E t
(For SI: 694,000 H2f′c / EI)
∆ = Deflection of top of bolt, inches (mm).
H = Wall height, feet (mm).
T = Thickness of the wall, inches (mm).
E = Modulus of elasticity of the wall material, pounds per square inch (kPa).
fc = Allowable flexural compressive strength of the wall material, pounds per square inch (kg/m3). For masonry fc = 0.33f’m; for concrete fc = 0.45f’c.
10. All end perimeter and interior members and their attachments must be designed to resist all applied loads.
FIGURE 7—NAIL HEAD STANDOFF (hNVS) FOR X-ENP-19 L15 FASTENER
FIGURE 8—NAIL HEAD STANDOFF (hnvs) FOR X-EDN19 THQ12 AND X-EDNK22 THQ12
FASTENERS
ESR-2197 | Most Widely Accepted and Trusted Page 27 of 27
694,000 2H f
Etc
H f
Etc
2
.01
TABLE 24—DIAPHRAGM FLEXIBILITY LIMITATION1,2,3,4,5
F
MAXIMUM SPAN IN FEET FOR
MASONRY OR CONCRETE WALLS
SPAN-DEPTH LIMITATION
Rotation Not Considered In Diaphragm Rotation Considered In Diaphragm
Masonry or Concrete Walls Flexible Walls Masonry or Concrete Walls Flexible Walls
More than 150 Not used Not used 2:1 Not used 11/2:1
70-150 200 2:1 or as required for deflection 3:1 Not used 2:1
10-70 400 21/2:1 or as required for deflection 4:1 As required for deflection 21/2:1
1-10 No limitation 3:1 or as required for deflection 5:1 As required for deflection 3:1
Less than 1 No limitation As required for deflection No limitation As required for deflection 31/2:1
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 plf = 14.594 N/m, 1 psi = 6894 Pa.
1Roof diaphragms shall be investigated regarding their flexibility and suggested span-depth ratio. Refer to the Tables for determination of F. 2When diaphragms are supporting masonry or concrete walls, the maximum deflection of the diaphragm should be computed using the loads in UBC Section 1612.3.1 and it should be limited to the amount δwall given by the following formula in inches (mm):
δwall = For SI:
where:
H = Unsupported height of wall, in feet (m) t = Thickness of wall, in inches (mm) E = Modulus of Elasticity of wall material for deflection determination, in pounds per square inch. (MPa) fc = Allowable compressive strength of wall material in flexure, in pounds per square inch (MPa). (fc = .45 f c for concrete and
fm = .33 f m for masonry)
3When applying these limitations to cantilever diaphragms, the suggested span-depth ratio shall be 1/2 of those shown. 4The total deflection ∆ of the diaphragm in inches (mm) shall be computed from the equation.
∆ = ∆f + ∆w. where: ∆f = Flexural deflection of the diaphragm in inches (mm) determined in the same manner as the deflection of beams.
∆w = The web deflection is determined by the equation
∆w = LlqaveF/106 (LlqaveF/175)
where: ∆w = Shear deflection of diaphragm web, in inches (mm) over span Ll
∆w = Shear deflection of diaphragm web, in inches (mm) over span Ll
F = Flexibility factor (the average micro inches a diaphragm web will deflect on a span of one foot under a shear load of one pound per foot.
Ll = Span between points for which deflection is determined, in feet (m). qave = Average required shear, in pounds per foot (KN/m) over span Ll
5Diaphragm classification (flexible or rigid) and deflection limits shall comply with Section 2.3.