ICARUSELECTRONIC GAS VOLUME CONVERTER
1. INTRODUCTION 2. TECHNICAL DETAILS
ICARUS is an electronic volume converter
which, combined with a gas meter, provides
the gas measurement in Sm3, calculated at
base conditions of + 15 C and 1,01325 bar.
ICARUS fully conforms to all current
European standards and directives, such as
EN 12405-1 and ATEX 94/9/EC, and is
certified according to MID n 2004/22/EC.
ICARUS is a type 1 device, manufactured
with integrated pressure and temperature
sensors.
2.1 Pressure Measurement
ICARUS is always fitted with an external
piezo-resistive absolute pressure sensor,connected to the processing unit by a cable
whose typical lenght is 3 mt.The sensor is enclosed in a stainless steel
casing.
The connection is G !, flat sealing.
Available full scale ranges: 2,5; 6; 10; 30;
81 bar A
Accuracy: 0,1% of the full scale.
-
7/24/2019 ICARUS EN
2/6
FIMIGAS S.p.A.Via C. Goldoni, 3 - 20063 CERNUSCO SUL NAVIGLIO (MI)Telefono n 02 9249234 - Fax n. 02 9249078E-mail: [email protected] http://www.fimigas.it
2.2 Temperature Measurement
ICARUS is always provided with a 4 wires PT
1000 sensor compliant with European
Standard EN IEC 60751 (its resistance value is
1000" at 0 C). 4 wires connection grants ahigh accuracy measurement despite cable
resistance.
The sensor is connected to the processing unitby a cable whose typical lenght is 3 mt.
The operating measuring range of the sensor is
-30C70C.
2.5 Outputs
- N 1 optical serial port to communicate
with a local PC (configuration setup, data
download).
- N 1 RS 232 serial port to connect to an
external GSM/GPRS modem, necessary to
achieve remote transmission of stored data
for tele-reading applications.- N 1 RS 485 serial port, used or to
communicate with a DCS by MODBUSRTU protocol, or to connect to an external
GSM/GPRS modem, necessary to achieveremote transmission of stored data for tele-
reading applications.
2.3 Signal inputs
ICARUS has an Open Collector high-
frequency input and a low-frequency pulse
input.When connected to a LF pulse emitter, gasmeter pulses are divided by a pulse weight
factor [pulse/m3] which is set in the device.
When Icarus is connected to a HF gas meter,
its Open Collector HF input must be
configured specifying:
- The pulse weight factor.
- The frequency value of the pulse train
corresponding to the maximum flow
rate.The maximum frequency that can be read
by the input is 5Khz. HF input can operate
only if ICARUS is powered by an external
main DC voltage supply.
- N 2 pulse outputs to transfer volume
pulses associated to internal counters, or the
presence of an alarm in the device.
- N 1 PWM (pulse with modulated) output,
by which its possible to have a 4-20 mAoutput associated to a parameter
(temperature, pressure or flow-rate), thanks
to an external converter that, located in safe
area, converts the PWM signal into 4-20
mA format.
- N 1 LAN connection by ethernet port and
n 4 4-20 mA outputs available on request.
2.6 Flow-rate calculation
ICARUS can calculate both measured flow-rate and base flow-rate (instantaneous or
average flow-rate).
The instantaneous flow-rate at measured gas
conditions (Qm) is calculated by counting the
number of read pulses and measuring the time
elapsed since the last calculation (minimumtime 15 seconds).
The instantaneous flow-rate at base gas
conditions is calculated thanks to the
following formula:
Qb = Qm x C
The average flow-rate Qb e Qm (stored every15 minutes) is calculated according to
Standard UNI TS 11291-4.
2.4 Conversion function
Referring to ISO 12405 European Standard,
ICARUS operates togheter with a gas meter to
convert the measured gas volume into base
conditions, according to the following
formula:!"" #$ !"
N 4 different algorithms for the calculation of
compressibility:
- SGERG 88
- AGA8 Gross 1
- AGA8 Gross 2
- AGA NX19
-
7/24/2019 ICARUS EN
3/6
FIMIGAS S.p.A.Via C. Goldoni, 3 - 20063 CERNUSCO SUL NAVIGLIO (MI)Telefono n 02 9249234 - Fax n. 02 9249078E-mail: [email protected] http://www.fimigas.it
2.7 Keypad 2.9 Power
The keypad is composed of five keys:
- Four directional arrow shaped keys
(Up, Down, Left, Right directions).
- One confirmation central key (OK).
Up/Down direction keys let the user:
- Scroll up/down the items in a menu
page.
- Move the cursor of the display from
one line to the upper/lower one.
Left/Right direction keys let the user:
-Return to the previous menu page.
- Move the cursor of the display
leftwards/rightwards.
OK key is used:
- To select a menu item.
- To confirm a parameter setup.
ICARUS can be powered by:
- Internal lithium battery (3.6V)
- External power (8Vdc)
ICARUS is always provided with an internal
battery satisfying ATEX requirement.The internal battery guarantees a life
autonomy of 5 years at normal user
conditions.
In presence of the external power (compulsory
to read HF incoming pulses or to activate the
RS 485 serial port) the battery operates as
backup power.
Attention: external power is supplied by a
specific model of power supply that is
ATEX certified.It may only be used a battery, or a certified
power supply, provided by Fimigas.
3. INSTALLATION SITE
ICARUS is generally installed in Zone 1
hazardous area next to the gas pipeline. It canbe connected to a modem to remotely transfer
recorded gas data. The modem shall always beinstalled in safe area and connected to
ICARUS by an intrinsically safe barrier. The
schemes reported below show the typical
installation of the device.
ICARUS enclosure is provided with 4 fixing
threaded holes positioned on the back corners
of the device. The internal diameter of the
holes is 4 mm.
By these holes ICARUS can be both wall-fixed and plate-fixed.
2.8 Display
The display of ICARUS lets the user:
- Visualize real time gas data.
- Visualize historical gas data.
- Visualize active alarms on the device.
- Visualize/modify setup.
- Calibrate pressure and temperature
sensors.
-
7/24/2019 ICARUS EN
4/6
FIMIGAS S.p.A.Via C. Goldoni, 3 - 20063 CERNUSCO SUL NAVIGLIO (MI)Telefono n 02 9249234 - Fax n. 02 9249078E-mail: [email protected] http://www.fimigas.it
-
7/24/2019 ICARUS EN
5/6
FIMIGAS S.p.A.Via C. Goldoni, 3 - 20063 CERNUSCO SUL NAVIGLIO (MI)Telefono n 02 9249234 - Fax n. 02 9249078E-mail: [email protected] http://www.fimigas.it
4. DATA READING 9. REFERENCE DIRECTIVES AND
STANDARDS
Directives
- European Directive 2004/22/EC related to
measurement instruments (MID), MI-002.
- European Directive 1994/9/EC related to
equipment and protective systems
intended to be used in potentially
explosive atmospheres (ATEX).
- European Directive 2006/95/EC related to
low voltage devices;
- European Directive 2004/108/EC related
to electromagnetic compatibility (EMC);
- European Directive 2002/95/EC related to
the use of hazardous substances in
electrical and electronic equipment(RoHs);
- European Directive 2002/96/EC related to
collection and recycling of electrical and
electronic equipment (WEE).
Standards
- Italian Standard UNI 9167-2009 related to
the design, manufacturing and test of
natural gas measurements systems;
- European Standard ISO 12405-1/A1, Gas
meters Conversion instruments Part 1:
Conversion of volume, 2005. related to
the technical specifics of type 2 volume
gas conversion devices. (this is the
harmonized Norm of the cited MID
Directive);
- EN-IEC 60079-0, Explosive atmospheres
Part 0: General requirements, 2007.- EN-IEC 60079-11, Explosive
atmospheres Part 11: Equipment
Protection by Intrinsic Safety, 2007.
ICARUS has ample memory space for data
storage.
All the values in storage can be read in two
different methods:
By remote reading of the device viaexternal GSM/GPRS.
By local connection to a PC, viaoptical or RS232/485 serial port.
ICARUS meets all the requirements of
the UNI 9167 Standard and is already
equipped with the CTE communication
protocol (upgradeable with future updates),
according to UNI TS 11291:2009.
5. ENVIRONMENTAL CONDITIONS
-Ambient Temperature: -25C 55C
- Storage Temperature: -40C 80C
- Relative Humidity: 0% 100%
6. MID CERTIFICATE
ICARUS received by International Institute of
Metrology the Certificate of Approval inaccordance with Directive MID (2004/22/CE):
MID Certificate: CH-MI002-12009-00
7. ATEX CERTIFICATE
ICARUS is an intrinsically safe device and it
has two ATEX markings:
ATEX Certificate: TUV 11 ATEX 556245 X
o Ex II 1G Ex ia IIC T4 Ga
o Ex II (1)G [Ex ia] IIC
8. DIMENSIONS AND WEIGHT
IP 66 plastic case.
Dimensions: 210 x 150 x 95 mm
Weight: 1,5 Kg.
-
7/24/2019 ICARUS EN
6/6
FIMIGAS S.p.A.Via C. Goldoni, 3 - 20063 CERNUSCO SUL NAVIGLIO (MI)Telefono n 02 9249234 - Fax n. 02 9249078E-mail: [email protected] http://www.fimigas.it
- IEC 60079-14: Explosive atmospheres
Part 14: Electrical installations design,
selection and erection
- IEC 60079-17: Explosive atmospheres
Part 17: Inspection & Maintenance Of
Installations In Hazardous Areas
-
EN-IEC 60079-28, Explosiveatmospheres Part 28: Protection of
Equipment and transmission Systems
using Optical radiation, 2006.
- EN-IEC 60079-26, Explosive
atmospheres Part 26: Equipment with
Equipment Protection Level (EPL) GA,
2007.
- EN-IEC 62056-21, Electricity metering
Data exchange for meter reading, tariff
and load control Part 21: Direct local
data exchange, 2002.
- European Standard ISO 12213-1/2/3
related to the calculation of gas
compressibility factor (Z factor);
- AGANX19 Standard related to the
calculation of Z gas compressibility
factor;
- European Standard ISO 6976 related to
the calculation of gas density;- International Standard IEC 60529,
Degrees of Protection Provided by
Enclosures (IP code), 2001.