Min. 323mm / 12”-23/32 Max. 627mm / 24”-23/32 281 mm 11”-1/16 174,4 mm 6”-7/8 364 mm 14”-21/64 Min. 237,5mm 9”-11/32 Max. 383mm 15”-3/32 384 mm 15”-1/8 Specification Sheet NORTH AMERICAN EDITION Delta Light nv HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca IC AT MEDIUM HOUSING APPLICATION Rough-in section for use in new construction applications Suited for insulation covering Suitable for damp locations Airtight , complies with ASTM E283 CEILING THICKNESS For 5/8” ceiling standard DISTANCE BETWEEN JOISTS Min.: 237,5mm = 9”-11/32 Max.: 627mm = 24”-23/32 SPECIFICATION FEATURES Galvanized steel construction 3-Dimensional adjustable hanger system Electronic power supply included Patented system for easy driver servicing from room side Listings Conforms to ANSI/UL Std. 1598 Cert. to CAN/CSA Std. 22.2 No. 250.0 1 6 202 XX 113 XX Rev. 01 02/08/2022

Upload: others

Post on 28-Apr-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IC AT HOUSING - Delta Light

Min. 323mm / 12”-23/32Max. 627mm / 24”-23/32

281 mm11”-1/16

174,4 mm6”-7/8

364 mm14”-21/64

Min. 237,5mm 9”-11/32

Max. 383mm15”-3/32

384 mm15”-1/8

Speci�cation SheetNORTH AMERICAN EDITION

Delta Light nv HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca

IC AT MEDIUM HOUSING

APPLICATIONRough-in section for use in new construction applicationsSuited for insulation coveringSuitable for damp locationsAirtight , complies with ASTM E283

CEILING THICKNESSFor 5/8” ceiling standard

DISTANCE BETWEEN JOISTSMin.: 237,5mm = 9”-11/32Max.: 627mm = 24”-23/32

SPECIFICATION FEATURESGalvanized steel construction3-Dimensional adjustable hanger systemElectronic power supply includedPatented system for easy driver servicing from room side

Listings

Conforms to ANSI/UL Std. 1598Cert. to CAN/CSA Std. 22.2 No. 250.0

16 202 XX 113 XX Rev. 01 02/08/2022

Page 2: IC AT HOUSING - Delta Light

1

OR

2

543

6

2x

OT OG OT OG 25

A

A

HANGERS ON THE LONG SIDE

Min. 237,5mm 9”-11/32

Max. 383mm15”-3/32

Min. 323mm12”-23/32

Max. 627mm24”-23/32

B A

9

7

8

13” minWhen a fixture is installed in a location that requires servicing from below the ceiling through the fixture aperture, the branch circuit connections need to be able to be brought out through the aperture. Leave an extra 13” branch wires in the wiring compartment or ther equivalent method.

HANGERS ON THE SHORT SIDE

Speci�cation SheetNORTH AMERICAN EDITION

Delta Light nv HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca

1

Conforms to ANSI/UL Std. 1598Cert. to CAN/CSA Std. 22.2 No. 250.0

6 202 XX 113 XX Rev. 01 02/08/2022

Page 3: IC AT HOUSING - Delta Light

16

MORE INFO FOR CEILING FINISHINGhttps://www.deltalight.com/downloads/CeilingFinishing.pdf

10

NL

CAUTION! - RISK OF FIRETHIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

ATTENTION! - RISQUE D’INCENDIECE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION PERTINENT,PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.

FIELD INSTALLED POWER LIMITED CIRCUITS SHALL HAVE MINIMUM 300V RATED INSULATED CONDUCTORS

12

DRYWALL CEILING PLASTER

MIN. Tolerance between fixture and opening = 2mm;1/16”

PAINT170mm x 92mm6” 11/16 x 3” 5/8

13 14 15

11 12

1/2”1 3 4

2

MAX 5 x 14-18AWG 50L/STR

+

L L

+

--

ED1

1/2”1 3 4

2

MAX 5 x 14-18AWG 50L/STR

E1

L L

E1

E2E2

ED13 - ECO SYSTEMED8/ED12

1/2”1 3 4

2

MAX 5 x 14-18AWG 50L/STR

L

N

L

N

N NN N

Speci�cation SheetNORTH AMERICAN EDITION

Delta Light nv HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca

26 202 XX 113 XX Rev. 01 02/08/2022