i-wob up3tmirricomp.com.au/manuals/i-wob up3 install sheet.pdf... ... [10.32 mm] #26...
TRANSCRIPT
Call (407) 877-5655 • Web: www.senninger.com®
PULL
PINCHPINCH
Nozzle Removal
CLICK
PLACEPLACE
Nozzle Installation Nozzle VisibilityWhole sizes Half sizes
Notches
BRACKETASSEMBLY
Standard Angle 6-Groove(Gray deflector)IWOB00B3SA6-UP3
Standard Angle 9-Groove(Black deflector)IWOB00B3-UP3
Low Angle 9-Groove (Blue deflector)IWOB00B3LA9-UP3
Low Angle 6-Groove (White deflector)IWOB00B3LA-UP3
The One Weight(0.85 LB) ONEWGT4
UP3 Nozzles #6 - #26
UP3NZ06 -UP3NZ26
UP3 Dual Nozzle CarrierUP3NZCD
Component Assembly
MS-102510 iWUP3-IN 09
1.Checkstarterbuttonwitha3/8inchhexwrenchtobesureitistightlyscrewedontothebracket.
2.IfusingTheOneWeight,alwaysbesureitistightlythreadedintothebottomofthei-Wob.
i-Wob® UP3TM
Recommended installation
AvailableDecember
2010
Call (407) 877-5655 • Web: www.senninger.com®
MS-102510 iWUP3-IN 09
Performance DataTo maintain product warranty, refer to the chart below
Standard Angle 6-Groove
Standard Angle 9-Groove
Low Angle9-Groove
Low Angle6-Groove
Droplet Sizes
Small Droplets Medium Droplets Medium Droplets Large DropletsNozzle Sizes
Minimum #10 9/64" [3.57 mm] #6 3/32" [2.38 mm] #6 3/32" [2.38 mm] #12 3/16" [4.76 mm]Maximum* #26 13/32" [10.32 mm] #26 13/32" [10.32 mm] #26 13/32" [10.32 mm] #26 13/32" [10.32 mm]Flows
Minimum 2.25 gpm [511 L/hr] 0.82 gpm [186 L/hr] 0.82 gpm [186 L/hr] 3.16 gpm [718 L/hr]Maximum 20.50 gpm [4656 L/hr] 20.50 gpm [4656 L/hr] 20.50 gpm [4656 L/hr] 20.50 gpm [4656 L/hr]Maximum Spacing**
at 6 ft [1.8 m] ground clearance 18 ft [5.5 m] 20 ft [6.1 m] 18 ft [5.5 m] 15 ft [4.6 m]Operating Press. at Noz.
Minimum 10 psi [0.69 bar] 10 psi [0.69 bar] 10 psi [0.69 bar] 10 psi [0.69 bar]Maximum 20 psi [1.38 bar] 20 psi [1.38 bar] 20 psi [1.38 bar] 20 psi [1.38 bar]
* It is recommended that larger nozzle sizes be used only on soils and slopes that can handle higher application rates.** For optimum performance Senninger recommends the use of maximum spacing for 1-2 spans only. Maintenance note: Keep i-Wobs above crop canopy when outlet spacing exceeds 10 ft [3 m]. This is especially important on high profile crops.
i-Wob System Assembly Mounting1.Alwaysmountthei-Wobonaminimumof2ft.[0.6m]reinforcedflexiblehose.
2.Mountthei-Wobnolessthan3ft.[0.91m]abovetheground.3.WhenusingTheOneWeight,alwaysbesureitistightlythreadedintothebottomofthei-Wob.
4.WhenusingTheOneWeight,neveruseanotherweightabovethei-Wob.
5.Ifusingaconventionaldropweight,neveruseathreadedlowerweightalso.
6.Ifusingaconventionaldropweightabovethei-Wob,onlyuseathreadedweightweighingatleast1.5lbs[0.7kg]butnotexceeding15ft.[0.38m]inlength.Pleasenotethatusinga“slip-over”dropweightmaycauseprematurefailureofthedroptubeassembly.
7.SeeSenningerGooseneckbrochureforadditionalmountingoptions.
Pressure Regulator Location1.Pressureregulatorscanbeinstalledatthetopofthedroporneartheapplicatorasshown.
2.Alwaysfollowyourcustomizedprintoutforproperpressureregulatorplacement.
Note: Selection of weight style (location) is based on application and preference. Only one style weight should be used per i-Wob.Important: To maintain product warranty and maximize drop component life, refer to the information and diagrams here. Minimum ground clearance:
3 ft. [0.91 m]
AvailableDecember
2010