hyundai electro electric systems electro2012_1.pdf · • vacuum circuit breakers (vcb) up to 36/38...

32
HYUNDAI Electro Electric Systems

Upload: others

Post on 19-Apr-2020

4 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

HYUNDAI Electro Electric SystemsHYUNDAI Electro Electric Systems

Page 2: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

Keeping a Green StepAs an integral division of Hyundai Heavy Industries, Electro Electric Systems (“HHI”) has

been designing, engineering and manufacturing electrical equipment for more than three

decades in collaboration with world-renowned technical partners in the industry.

We have developed HHI's own quality assurance program complying with the requirements

of ISO9001-1994 to assure that HHI products are designed, manufactured, inspected,

tested, and delivered according to global standards. Our focus is also on the human

element, which we consider the most important in our efforts to enhance safety as well as

environmental protection in accordance with ISO 14000.

We will dedicate our efforts to the supply of the best quality products and services for a

green future.

Page 3: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

We are greatly pleased to present our company's general brochure, to help you gain a

better understanding of our core business activities.

As you will see in the following pages, our product lines cover a wide range of electrical

equipment, such as transformers, gas insulated switchgear(GIS), switchgear, LV & MV circuit

breakers, motors, generators, integrated control & monitoring systems, and power electronics.

For more than 30 years Hyundai has accumulated an enormous amount of experience in

power industries enabling us to provide turnkey solutions for our clients.

In order to satisfy our clients with the best quality products and services, we have established a

complete quality assurance program, from marketing to after-sales service, to comply with the

requirements of ISO 9001 and ISO 14001.

Through our assurance program we have an exceptional reputation and performance record

for products and services provided to our clients around the world.

We look forward to serving your interests the best way we can.

Yours sincerely,

Oh-Shin Kwon

Chief Operating Officer

“Towards a better future”

Page 4: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •
Page 5: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

10 Transformers | 12 Gas Insulated Switchgear | 14 Switchgear | 16 LV & MV Circuit Breakers

18 Rotating Machinery | 20 Electrical Marine Equipment | 22 Integrated Control & Monitoring Systems

24 Power Electronics | 26 Turnkey Substations | 28 Research & Development

� < Business Areas

Your green partner for a better future!

With a variety of products and proven engineering capabilities in every field of

the electrical industry, we are fully prepared to meet the most demanding

requirements and to provide turnkey solutions.

Our high quality products and services will satisfy our clients whenever and

wherever they need us.

Total Solution for Electrical & Automation Equipment

Page 6: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

1970

1980

1977 Feb. Established Electrical Engineering Division

(EED) as a new division of Hyundai Heavy

Industries

1978 Jan. Switchgear Factory Completed

1978 Oct. Completed Transformer Factory

1978 Nov. Incorporation of the Company as

Hyundai Electrical Engineering (HEECO)

1979 Aug. Completed Rotating Machinery Factory

1979 Sep. Dedicated High Voltage Transformer Test

Laboratory

1982 Dec. Established Hyundai Industrial Research

Institute

1983 Dec. Completed Circuit Breaker Factory

1984 Dec. Completed Power Electronics Factory

1986 Jun. Established Low Voltage Motor Factory

“HIMCO” (Joint Venture with General Electric)

1989 May Completed High Voltage Switchgear Factory

Page 7: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

1990

2000

1994 Jan. Merged with Hyundai Heavy Industries

1996 Nov. Completed Turbine & Generator Factory

1997 Jul. Acquired Elprom Trafo Co. in Bulgaria

1998 Oct. Established Research & Development

Company in Hungary, named HUNELEC

Engineering & Technology Co.

(The current name is Hyundai

Technologies Center Hungary)

1999 Nov. Completed 800kV Transformer, GIS

Factory & Test Facility

2001 Jan. Renamed Electro Electric Systems (EES) Division

2001 Jun. Developed 800kV Gas Insulated Switchgear

2003 Oct. Incorporated Jiangsu-Hyundai Electrical Company

in China (The current name is Hyundai Heavy

Industries (China) Electric)

2007 Apr. Acquired Ideal Electric Company in U.S.A.

and incorporated Hyundai Ideal Electric Company

2008 May Completed Solar Cell / Module Factory

2009 Aug. Completed Wind Turbine Factory

2010 Dec. Achieved total 700,000MVA production in

Transformers

2011 Jan. Established Green Energy Division as a new division

of Hyundai Heavy Industries specializing in

Solar Power and Wind Turbine Business

Brief HistoryIn the face of a great challenge and with an

unyielding will to become one of the world's top

industrial leader, we have made significant

strides in the field of modern electric technology.

Page 8: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

Transformers

�Power & Distribution Transformers

�Cast Resin Transformers

�Special Purpose Transformers

�Shunt Reactors

Gas InsulatedSwitchgear

�24 kV, 72.5 kV, 145 kV, 170 kV, 245 kV, 362 kV,

420 kV, 550 kV, 800 kV

RotatingMachinery

�Induction Motors & Generators

�Synchronous Motors & Generators

�Diesel Engine Generator Sets

�Wind Turbine Generators

�Co-generation Systems

Electrical MarineEquipment

�Main Switchboards

�Ship Automation Systems

�Control Consoles

�Synchronous Generators

Business Divisions

Page 9: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

Switchgear

�Medium Voltage Switchgear

�Cubicle-type Gas Insulated Switchgear

�Low Voltage Switchgear & Motor Control Centers

�Intelligent Measuring & Protection Devices

LV&MV CircuitBreakers

�Vacuum Circuit Breakers

�Air Circuit Breakers

�Molded Case Circuit Breakers

�Magnetic Contactors & Overload Relays

�Miniature Circuit Breakers

Integrated Control &Monitoring Systems

�SCADA System

�DCS

PowerElectronics

�General Purpose Inverter

�Solar Inverter

�Rolling Stock Propulsion Systems

�Electric Vehicle Propulsion Equipment

�Battery Chargers

Page 10: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

01 Transformers

Page 11: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 10 | 11

� < Transformers

Using modern designs, state-of-the-art manufacturing facilities and innovative production technology,

we manufacture high-quality power and distribution transformers with a rated voltage of up to 800 kV

and a capacity of up to 1,500 MVA.

HHI’s transformers are in service around the world and meet international standards such as IEC, ANSI,

NEMA, CSA, AS, and ES.

Prominent Features / Benefits:

• Suitable for various site conditions and sufficient supply records proven by worldwide end-users

• Environmentally friendly with low loss, low noise and compact design

• High reliablity and long service life

Production Range:

• Power Transformers up to 800 kV Class

• Distribution Transformers

• Cast Resin Transformers

• Special Purpose Transformers such as Dry Type Transformers,

Shunt Reactors, Gas Insulated Transformers, etc.

B C

D E F

A 765 kV Power Transformer

B 500 kV Power Transformer

C 362 kV Power Transformer

D TPRS (Tank Pressure Relief System) Transformer

E Cast Resin Transformer

F Gas Insulated Transformer

A

Page 12: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

02 Gas Insulated Switchgear

Page 13: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 12 | 13

� < Gas Insulated Switchgear

SF6 Gas Insulated Switchgear(GIS) is a major piece of electrical equipment used in a substation.

It contains a gas circuit breaker, disconnecting switch, earthing switch, voltage transformer, current

transformer, and lightning arrester in a grounded metallic enclosure. The switchgear is filled with SF6

gas, which has the best insulation and arc-quenching capability.

With its outstanding technical features, Hyundai GIS can meet all your requirements.

Prominent Features / Benefits:

• Space saving compact design

• Easy installation

• Simple maintenance

• Full protection against contact with live parts

• Protection against pollution

• Visual harmony with surroundings

Production Range:

SF6 Gas Insulated Switchgear (GIS)

• Rated voltage: 24 kV, 72.5 kV, 145 kV, 170 kV, 245 kV, 362 kV, 420 kV,

550 kV, 800 kV

• Rated short-circuit breaking current: 20-63 kA

B C

D E

A 800 kV Gas Insulated Switchgear

B 362 kV Gas Insulated Switchgear

C 245 kV Gas Insulated Switchgear

D 170 kV Gas Insulated Switchgear

E 145 kV Gas Insulated Switchgear

A

Page 14: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

03 Switchgear

Page 15: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 14 | 15

� < Switchgear

HHI’s switchgear offers the best solutions in the field of electric power distribution, protection,

measuring, control and communication in power plants as well as industrial and public facilities.

Combined with advanced software and hardware, our products are designed, manufactured and tested in

accordance with industrial standards including IEC, ANSI, NEMA, BS, and IEEE.

Prominent Features / Benefits:• Hyundai Metal-clad Switchgear provides maximum circuit separation and safety with an isolated

and grounded metal compartment.

• Able to withstand high levels of seismic vibration without service interruption.

• Space-saving compactness helps simplify a layout.

• Qualified for all aspects of applications, including nuclear power plants.

Production Range:

• Air Insulated Medium Voltage Metal-clad Switchgear up to 38 kV

• Cubicle-type Gas Insulated Switchgear up to 40.5 kV

• Low Voltage Switchgear & Motor Control Centers.

• Non-segregated Phase Bus & Bus Way.

• Intelligent Measuring & Protection Devices.

• Intelligent Power Management Systems.

• Intelligent Preventive Diagnostic System for Transformers.

• Current Transformers & Potential Transformers.

B C

D E

A Cubicle-type Gas Insulated Switchgear

B Motor Control Center

C Hyundai Intelligent Measuring and Protection Device (HiMAP)

D Ring Main Unit

E Hyundai Power Management System (HiPMS)

A

Page 16: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

04 LV & MV Circuit Breakers

Page 17: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 16 | 17

� < LV & MV Circuit Breakers

HHI’s circuit breakers and contactors offer the best circuit protection and switching performance for

low and medium voltage power systems. Our products cover a wide range of breaking capacities and

provide innovative solutions that satisfy your safety needs.

Pursuing flexibility, safety and reliability, our products are type-tested by internationally

recognized test authorities such as KEMA, KERI, and CESI.

Prominent Features / Benefits:

• Wide and powerful range for various applications such as construction, industrial, nuclear power plants and shipyards.

• Modern and customized design for easy installation and maintenance.

• High reliability based on advanced technology and R&D.

• Satisfaction of international standards like IEC, ANSI, and NEMA.

• Standardized process for local standards and approvals that requested by customers.

Production Range:

• Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A

• Vacuum Contactors (VC) up to 12 kV 400 A

• Air Circuit Breakers (ACB) up to 6,300 A, up to 130 kA

• Molded Case Circuit Breakers (MCCB) up to 1,600 A, up to 150 kA

• Magnetic Contactors (MC) up to 800 A

• Digital & Thermal Type Overload Relays up to 800 A

• Miniature Circuit Breakers (MCB) up to 10 kA, 125 A

B C

D E

A

A Vacuum Circuit Breaker

B Air Circuit Breaker

C Molded Case Circuit Breaker

D Magnetic Contactor

E Miniature Circuit Breaker

Page 18: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

05 Rotating Machinery

Page 19: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 18 | 19

� < Rotating Machineries

HHI supplies high quality rotating machines attested by international rules and authorities such as

IEC, NEMA, CSA, IEEE, KS, JEC, PTB and KOSHA for industrial applications and LR, ABS, DNV

and KR for marine use.

We have a rich performance record of providing the latest technology for motors and generators in the

fields of power, desalination, chemical, oil & gas as well as ocean-going vessels.

Prominent Features / Benefits:• Low vibration and noise through precise rotor dynamic balancing and electromagnetic noise analysis

• Robust frames to satisfy various load conditions by FEM and vibration test

• Optimized insulation system to guarantee durability against severe environmental conditions

• Customized engineering to clients’ various specifications

Production Range:

• Medium & High Voltage Induction Motors up to 25,000 HP 14 kV

• Standard Low Voltage Induction Motors up to 1,000 HP

• Premium Efficiency Low Voltage Motors from 1 HP to 250 HP

• Synchronous Generators up to 50,000 kVA 14 kV

• Wind Turbine Generators

• Co-generation Systems

B C

D E

A Medium & High Voltage Motor

B Low Voltage Motor

C Synchronous Generator

D Wind Turbine Generator

E Co-generation System

A

Page 20: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

06 Electrical Marine Equipment

Page 21: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 20 | 21

� < Electrical Marine Equipment

HHI’s marine electrical products include dry-type transformers, generators, main switchboards,

engine control room consoles, bridge control consoles, automation systems and various panels.

These equipments have been installed on a large number of ocean-going vessels and are highly regarded

for their economy, efficiency, and outstanding performance.

These products have been widely recognized by not only the major classification societies of LRS, ABS,

DNV, GL, BV, NK and KR but also by leading shipowners around the world.

Main SwitchboardsHHI has accumulated decades of experience with marine electrical power distribution and control systems.

Reliable designs of power distribution systems and coordination of protective devices ensure continuity of

service.

Ship Automation SystemHHI’s ACONIS series offers the operator full integration of all control & automation functions in combination with

several systems, such as integrated bridge system, CCTV, Internet and ship’s computer systems.

Control Consoles Both conventional and microprocessor-powered automation control systems prevent every possible

malfunction caused by ship motion.

Synchronous Generators For its outstanding performance, Hyundai Synchronous Generators received wide recognition from

shipowners and have been installed on many ocean-going vessels.

B C

D E

A

A High Voltage Switchboard

B Bridge Console

C Advanced Control & Integration System (ACONIS)

D Water Cooling Generator

E L2 Compressor Motor

Page 22: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

07 Integrated Control & Monitoring Systems

HHI supplies various kinds of computerized control systems. The major products for industrial

computer systems are Distributed Control System (DCS) and Supervisory Control and Data

Acquisition (SCADA) System.

Both are very flexible and easy to access systems in terms of portability, scalability, interoperability

and connectivity.

Page 23: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 22 | 23

�< Integrated Control & Monitoring Systems

• Distributed processing

architecture

• Open system network

• Fully redundant data highway

• Embedded control blocks for

dedicated control

• Windows based HMI

• Complies with industry standards

including OPC.

• Web-based user interface

B

•••A HiMAX-2000 DCS

B SCADA System

A

SCADA System

To provide a truly open SCADA platform for efficient integration of third-party software applications and

system standard software / hardware, all software generation and hardware selections are designed and

manufactured to meet industry standards.

Features and Design Criteria of SCADA :

• Fully redundant data highway

• Distributed processing architecture

• X-Window or Windows based HMI

• Open System Network

• Support of multiple major RTU protocols (Modbus, DNP V3.0, IEC60870-5)

• Easy upgrade of modular software design

• Multi-level client/server structure

• Guarantee to create any up-to-date system structure

• Facility of migration to any structure in the future without upgrade costs

• Web-based user interface

DCS

HHI’s HiMAX-2000 DCS comprises a full range of state-of-the-art distributed control systems for

applications of CCPP, water & waste water treatment, and incinerator plants.

HiMAX-2000 DCS features powerful and versatile functions for various kinds of plants and is easily used in

HMI and configuration tools. HiMAX-2000 DCS can be ported on multiple hardware platforms and operating

systems to suit clients’ specific requirements.

Features and Design Criteria of HiMAX-2000 :

Page 24: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

08 Power Electronics

HHI’s inverters feature sensorless vector controls and intelligent controls that allow motors to operate

more efficiently. We also offer you a full range of inverters from 0.4kW to 6,400kW with international

certificate as CE, UL.

Page 25: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 24 | 25

� < Power Electronics

Inverter

General Purpose Inverter

• Precise operation using sensorless and sensored vector control

• Quick response through a built-in DSP

• AVR function to ensure high starting torque

Solar Inverter

• Compact design, lightweight, and easy installation

• Maximum efficiency with high performance MPPT control

• Increased flexibility due to a wide range of MPPT tracking

• Remote and local data monitoring

• LCD display of operating status

• Auto-tuning function for convenient start-up

• 220 V & 440 V Class: 0.4-380 kW

• 3.3 kV, 4.16 kV & 6.6 kV Class: 155-6,400 kW

• Over-/Under-Voltage and frequency protection

• Solar inverter from 3 kW to 500 kW

Rolling Stock Propulsion System

Prominent Features / Benefits:

Traction Power Supply / Auxiliary Power Supply

• Fully integrated digital circuit using 32 bit DSP

• Advanced algorithm adoption

• Self-diagnosis on operation

• More convenient human-machine communications

• Heat pipe cooling method

Traction Transformer

• Compact & light-weight

• High temperature insulation system

• Vibration-proof / Impact-proof

• High efficient cooling design

Train Control & Supervisory Control System

• Easy manageability

• Fail-safe control data transmission

• Highly reliable system

• High speed data transmission

• Improved display device

• Easy to draw out failure record

B

F

C

D E

A Medium Voltage Inverter Panel

B N700E Inverter

C Solar Inverter (250 kW)

D Solar Inverter (4 kW)

E TractionPower Supply

F Traction Transformer

A

Page 26: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

09 Turnkey Substations

Page 27: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 26 | 27

� < Turnkey Substations

Drawing on three decades of successful performance in engineering and manufacturing a variety of

electrical equipments, HHI provides turnkey substations as well as AC system solutions.

Our scope of supply covers project development, manufacturing and erection of substations on a turnkey

basis, including civil works. Hyundai is able to comply with our customers various requirements and

meet their needs of tomorrow.

Our proven technical expertise and industry experience have resulted in achieving an internationally

recognized position as a total solution provider in the field of turnkey substations ranging from 72.5 kV

up to 800 kV.

B C

D E

A 800 kV Gas Insulated Switchgear

B HiMAX-2000 DCS

C 500 kV Power Transformer

D Solar Power System

E Medium Voltage Metal-clad Switchgear

A

Scope ofTurnkey Project

Engineering Works Test, Commissing, Supervision & Training

Erection Works

Civil & Architectural Works

Control, Protection & SCADA

Transformer, Gas Insulated Switchgear,LV & MV Switchgear, Battery Charger, etc.

Page 28: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

10 Research & Development

Our commitment to research and development has been a motivating factor in our company’s technical

achievements and it will be vital to our continued success in the 21st century.

We operate three renowned in-house research institutes: HMRI (Hyundai Maritime Research Institute),

HIRI (Hyundai Industrial Research Institute), and HEMRI (Hyundai Electro-Mechanical Research Institute),

as well as an overseas institute in Budapest, Hungary.

These institutes are fully equipped with state-of-the-art R & D equipment used by specialists to explore the

possibilities of the future.

Research & Development

Page 29: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

ELECTRO ELECTRIC SYSTEMS 28 | 29

� < Research & Development

HHI's policy is to meet all contract specifications and requirements. Our quality assurance

programs are designed, organized and implemented to ensure its strict standards for quality.

All of our divisions have received ISO 9001 Quality Management Certification, as well as ISO 14001

Environmental Management System Certification.

Our well-developed resources for training enable HHI to continue to provide you with high quality,

reliable products and better services.

TDI (Techno Design Institute)

TDI was established in October 2000 and plays a major role in coordinating design development.

The institute supports optimal design technologies by supplying new designs for various products and

constructions.

The Visual Communication Design Department is creating and refining colors, web based design, and

corporate or brand identities, and the Product Design Department develops and defines products’ identities.

TDI resolves problems quickly and improves design processes. It also contributes to the creation of a new culture

of enterprise and works to actualize high value business by obtaining its own design technologies.

Quality Assurance

Certificate Year Authority Field

ISO 9001 1990QMI (Canada)

All ProductsSAQAS (Australia)

ISO 14001 1997 DNV (Norway) All Products

OHSAS 18001 2001 DNV-QA All Products

KEPIC 1997 KEA (Korea) Products for Nuclear Power Plant

CE Marking 1998 TÜV (Germany) Induction Motor

CSA 1997 CSA (Canada) LV & HV Motor

Molded Case Circuit Breaker

KS 1986 KSA (Korea)Air Circuit Breaker

Residential Panel Board

Induction Motor

UL2001

ULInduction Motor

2010 Vacuum Contactor

Vacuum Circuit Breaker

KERI 2002 KERI(Korea) Air Circuit Breaker

Magnetic Contactor

KEMA 2007 KEMA(Netherlands)Molded Case Circuit Breaker

Miniature Circuit Breaker

ATEX 2008 Baseefa(England)Ex nA Ⅱ T3 or T4

(Totally Enclosed Type Motors)

CE & UL 2009 UL(Korea) Inverter

JET 2010 JET(Japan) Solar Inverter

Page 30: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

NORTH AMERICA

U.S.A.ORLANDO4700 Millenia Blvd, Suite 370,

Orlando, Florida 32839,

USA

Tel : 1-407-249-7350

Fax: 1-407-275-4940

NEW JERSEY300 Sylvan Avenue, Englewood

Cliffs, New Jersey 07632,

USA

Tel : 1-201-816-0286/8028

Fax: 1-201-816-4083

HOUSTON1400 Broadfield, Suite 110, Park

10 Center Houston, Texas 77084,

USA

Tel : 1-281-578-7097, 7802

Fax: 1-281-578-8317

CHICAGO(Hyundai Construction Equip.

U.S.A. Inc.) 1090 Fargo Avenue

Elk Grove Village, IL60007,

USA

Tel : 1-847-228-8845

Fax: 1-847-437-3574

PANAMA(Hyundai Heavy Industries Co., Ltd.

Panama Office) AVE, Samuel

Lewis, Edif. HSBC, Piso 12,

Obarrio, Panama City, Panama

Tel : 507-213-7657~9

Fax: 507-213-7660

EUROPE

UNITED KINGDOMLONDON2nd Floor, The Triangle, 5-17

Hammersmith Grove London, W6

0LG, UK

Tel : 44-20-8741-0501

Fax: 44-20-8741-5620

BELGIUMGEEL(Hyundai Heavy Industries Europe NV)

Vossendaal 11, 2440 Geel, Belgium

Tel : 32-14-56-2211

Fax: 32-14-59-3405

SPAINMADRIDPaseo De La Castellana 216,

planta 0, 28046 Madrid, Spain

Tel : 34-91-732-0454

Fax: 34-91-733-2389

NORWAYOSLOHyundai Oslo (Liaison) Office

Raadhusgt. 20, 0151 Oslo,

Norway

Tel : 47-2310-0890

Fax: 47-2310-0899

GREECEATHENS73, Posidonos Avenue, 175 62,

Paleo Faliro, Athens,

Greece

Tel : 30-210-428-2992

Fax: 30-210-428-2144

NETHERLANDSROTTERDAMFolkert Elsingastraat 7,

3067 NW, Rotterdam,

The Netherlands

Tel : 31-10-212-1567

Fax: 31-10-212-5134

RUSSIAMOSCOWWorld Trade Center, Ent. 3#

1902, Krasnopresnenskays Nab.

12, Moscow, 123610, Russia

Tel : 7-495-258-1381

Fax: 7-495-258-1382

AFRICA

ANGOLALUANDARua Lucrecia Paim, No. 28/30

Luanda, Angola

Tel : 244-222-370-669/692

Fax: 244-222-399-667

ASIA

JAPANTOKYO8th Fl., Yurakucho Denki Bldg. 1-7-1

Yuraku-cho, Chiyoda-ku, Tokyo,

100-0006, Japan

Tel : 81-3-3212-2076/3215-7159

Fax: 81-3-3211-2093

OSAKAI-Room 5th Floor Nagahori Plaza

Bldg. 2-4-8 Minami Senba, Chuo-

Ku, Osaka, 542-0081, Japan

Tel : 81-6-6261-5766~7

Fax: 81-6-6261-5818

SINGAPORE7 Temasek Boulevard, #41-02 Suntec

Tower One 038987, Singapore

Tel : 65-6337-2366

Fax: 65-6337-8966

OSLO

CHANGZHOU

BEIJING

ZAPOROZHYE

MOSCOW

KUWAIT

RIYADH

MADRID

ROTTERDAM

DUBAI

MUMBAI

SINGAPORE

YANTAI

YANGZHONG

TOKYOSOFIA

OSAKA

LUANDA

ISTANBULATHENS

BUDAPEST

LONDON

GEEL

Gas Insulated Switchgear, L/V & M/V Switchgear,Low Voltage Circuit Breakers

HYUNDAI HEAVY INDUSTRIES(CHINA)ELECTRIC CO., LTD.

Transformers, Tap Changers

HYUNDAI HEAVY INDUSTRIES CO.-BULGARIA

Overseas Network

Page 31: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

INDIAMUMBAIHyundai Heavy Industries-

Mumbai Liaison Office

5th Floor, East Quadrant,

The IL & FS Financial Centre,

Plot No. C-22, GBlock,

Bandra-kurla Complex,

Bandra(E), Mumbai 400 051,

India

Tel : 91-22-2653-3420~26

Fax: 91-22-2653-3429~30

CHINACHANGZHOU(Hyundai (Jiangsu) Construction

Machinery Co., Ltd.) 288, Hehai

West Road, Xinbei District,

Changzhou, Jiangsu 213022,

China

Tel : 86-519-519-1002, 1020

Fax: 86-519-519-1385

BEIJING(Beijing Hyundai Jingcheng

Construction Machinary Co.,

Ltd.) No. 2 Nanli, Luguoqiao,

Fengtai District, Beijing,

China

Tel : 86-10-8321-8347~8

Fax: 86-10-8321-1353

YANTAI(Yantai Hyundai Moon Heavy

Industries Co., Ltd.)

No. 333 Changjiang Road,

Yantai Etda, Shandong, China

Tel : 86-535-216-5800~1

Fax: 86-535-216-5810/5830

MIDDLE EAST

TURKEYISTANBULDereboyu Caddesi Meydan

Sokak Beybi Giz Plaza Kat. 8

No.30 Maslak, Istanbul,

Turkey

Tel : 90-212-290-2860~1

Fax: 90-212-290-2862

UAEDUBAI205, Building 4, Emaar Square,

Sheikh Zayed Road, Pobox

252458, Dubai, UAE

Tel : 971-4-425-7995

Fax: 971-4-425-7996

KUWAITFloor 15, Al Sour Tower, Al

Sour Street, Al-Qiblah, Kuwait

Tel : 965-2291-5354

SAUDI ARABIARIYADH2nd Floor, the Plaza, P. O. Box

21840 Riyadh 11485, Saudi

Arabia

Tel : 966-1-462-2331

Fax: 966-1-464-4696

CHINA●YANGZHONG(Hyundai Heavy Industries

(China) Electric Co., Ltd.) No.

9 Xiandai Road, Xinba

Scientific and Technologic

Zone, Yangzhong, Jiangsu,

P.R.C. Zip: 212212,

China

Tel : 86-511-8842-0666/0212

Fax: 86-511-8842-0668/0231

BULGARIA●SOFIA(Hyundai Heavy Industries

Co., Bulgaria) 1271, Sofia 41,

Rojen Blvd., Bulgaria

Tel : 359-2-803-3200

Fax: 359-2-803-3203

U.S.A.●OHIO(Hyundai Ideal Electric Co.)

330 East First Street,

Mansfield, OH 44902,

U.S.A.

Tel : 419-522-3611

Fax: 419-522-9386

●MONTGOMERY(Hyundai Power Transformer

USA) 600 South Court Street,

Suite 316 Montgomery,

AL36104, U.S.A.

Tel : 1-334-230-9921

Fax: 1-334-240-6869

HUNGARY ●BUDAPEST(Hyundai Technologies

Center, Hungary, Ltd.) 1146

Budapest, Hermina UT22,

Hungary

Tel : 36-1-273-3730/3733

Fax: 36-1-220-6708

CHICAGO

MONTGOMERY

OHIO

NEW JERSEY

ORLANDO

PANAMA

HOUSTON

Generators, Motors, Switchgear & Controls, Syn. Condenser

HYUNDAI IDEAL ELECTRIC COMPANY

Transformers

HYUNDAI POWER TRANSFORMERS USA, INC.

●Overseas plant ●R&D center

Page 32: HYUNDAI Electro Electric Systems Electro2012_1.pdf · • Vacuum Circuit Breakers (VCB) up to 36/38 kV, up to 50 kA, up to 4,000 A • Vacuum Contactors (VC) up to 12 kV 400 A •

www.hyundai-elec.comwww.hyundai-elec.com

Head Office 1000, Bangeojinsunhwan-doro, Dong-gu, Ulsan, Korea Tel: 82-52-202-8101~8 Fax: 82-52-202-8100

Seoul Office 75, Yulgok-ro, Jongno-gu, Seoul, Korea Tel: 82-2-746-7585, 7896, 7555, 7623, 8568 Fax: 82-2-746-7648, 7679