hydride effect on cladding behaviour for spent fuel storage and transport conditions ·...

18
ENUSA PROPRIETARY - CONFIDENTIAL Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions IAEA- International Conference on Management of Spent Fuel Vienna, Austria , 15 – 19 June 2015 M. Lloret (ENUSA) J.M. Rey Gayo (CSN) –F.J. Fernández (ENRESA)

Upload: others

Post on 22-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

ENUSA PROPRIETARY - CONFIDENTIAL

Hydride Effect on Cladding Behaviour for Spent Fuel Storage

and Transport Conditions

IAEA- International Conference on Management of Spent Fuel

Vienna, Austria , 15 – 19 June 2015

M. Lloret (ENUSA)

J.M. Rey Gayo (CSN) –F.J. Fernández (ENRESA)

Page 2: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

2 ENUSA PROPRIETARY - CONFIDENTIAL

Spanish Fuel Cycle Strategy - Open Cycle

REACTOR

INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TRANSPORT

ENUSA FACTORY

SPENT FUEL POOL

(re-racking)

URANIUM

3 ISFSI in operation Designed in detail Being licensed

Operation in 2018

CENTRALIZED INTERIM STORAGE (ATC)

Page 3: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

3 ENUSA PROPRIETARY - CONFIDENTIAL

SAFETY FUNCTIONS

Subcriticality Confinement

Retrievability Heat Removal

Shielding

Key Parameter

Cladding Integrity

Dry Spent Fuel Storage and Transport

Requirements in standards

10CFR 71 / 10 CFR 72

No gross cladding rupture

Geometric form not altered

Cladding Failure mechanism

Creep

Hydride embrittlement

Good behaviour Analyzed in other R&D projects (1)

Objective of the R&D project presented today (1) M. Quecedo et al. “Results of Thermal Creep Test on Highly

Irradiated ZIRLO”. WRFPM 2008. Korea M. Lloret et al. “Results of thermal creep tests on irradiated Zry-2”, TopFuel meeting, Manchester, UK, 2012

Page 4: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

4 ENUSA PROPRIETARY - CONFIDENTIAL

R&D Project

Objective: Effect of hydrides in cladding behaviour during dry storage and transport

Material: Prehidrurated/ Non irradiated ZIRLO Cold Work Stress Relieved (CWSR)

Results presented: Cladding Hidruration

Hydride reorientation

Ring Compression Tests

Effect of Circumferential vs Radial Hydrides

Fractographic analysis

Failure criteria

Page 5: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

5 ENUSA PROPRIETARY - CONFIDENTIAL

Cladding hidruration

• Cathodic Charge technique in KOH solution

Parameters can be adjusted to obtain different H

concentrations

• Thermal treatment Homogeneous distribution along hoop direction

Zr cathode Cladding sample

Pt anode

450oC

20oC

Page 6: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

6 ENUSA PROPRIETARY - CONFIDENTIAL

Cladding hidruration

• 150 – 500-1200-2000 ppm hydrogen

150 ppm 500 ppm 1200 ppm

Page 7: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

7 ENUSA PROPRIETARY - CONFIDENTIAL

Hydride reorientation along radial direction

Circumferential stress

0-60-90-120-140 MPa

Termomechanical treatment

400oC

20oC

Constant hoop stress during cooling down: Thermal dilatation considered and load

decreases as temperature decreases

Page 8: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

8 ENUSA PROPRIETARY - CONFIDENTIAL

Hydride reorientation along radial direction

150 ppm

90 MPa 140 MPa

1200 ppm

Cladding samples

Page 9: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

9 ENUSA PROPRIETARY - CONFIDENTIAL

Hydride reorientation • Fn factor (reoriented hydride percentage) has been calculated

for de 3 hydrogen concentration • It has been calculated following ASTM B811

σѲ MPa

Fn %

Highest reorientation factor for 150 ppm Similar values and evolution for 500 and 1200 ppm

Page 10: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

10 ENUSA PROPRIETARY - CONFIDENTIAL

Ring Compression Tests

Representative Load-Displacement curve

Displacement (mm)

Load

(kN

)

Higher stresses Load decrease Crack initiation

Mechanical tests has been performed on different hydrides morphologies samples to evaluate the cladding structural integrity

Page 11: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

11 ENUSA PROPRIETARY - CONFIDENTIAL

RCT - Circumferential Hydrides

HYDROGEN INCREASE

Yield strength / Young Modulus

No dependence with [H]

[ H ] displacement for crack initiation

Displacement always higher than 3mm

Test Conditions Temperature: 20, 135, 300 oC Hydrogen content: 150, 250, 500, 1200, 2000 ppm

20 oC

Page 12: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

12 ENUSA PROPRIETARY - CONFIDENTIAL

RCT- Circumferential Hydrides

Ductility is not a problem with circumferential hydrides

Similar results for 135 and 300 oC

Results for the same hydrogen concentration (1200 ppm) and different temperature Temperature effect as expected:

Same Young’s Modulus Lower Yield Stress at higher Temperature

Displacement for crack initiation always higher than 3 mm

Displacement

Loa

d

Page 13: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

13 ENUSA PROPRIETARY - CONFIDENTIAL

RCT- Radial Hydrides Test Conditions

Temperature: 20, 135, 300 oC Hydrogen content: 150, 500, 1200 ppm Reorientation Hoop Stress: 60, 90, 120, 140 MPa

300 oC

Displacement Displacement

Load

Loa

d

300oC DUCTILE BEHAVIOUR

No effect of reoriented hydrides

Enough ductility

Page 14: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

14 ENUSA PROPRIETARY - CONFIDENTIAL

RCT- Radial Hydrides

No effect of reoriented hydrides

135 oC

Displacement Displacement Displacement

Load

Load

Load

Enough ductility Rupture displacement almost independent of

radial hydrides

150 ppm Relevant effect of radial

hydrides

Higher radial effect for lower hydrogen content Related with Radial-Hydride-Continuity Factor (RHCF) (2)

(2) M.C. Billone, T.A. Burtseva, R.E. Einzenger, JNM 433 (2013) 431-448

DUCTILE BEHAVIOUR EXCEPT FOR 150PPM AND 140 MPA

Page 15: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

15 ENUSA PROPRIETARY - CONFIDENTIAL

RCT- Radial Hydrides

• Important effect of radial hydrides • Relevant decrease of displacement for failure when radial hydrides increase • Rupture in elastic zone in some cases for reorientation stresses higher 90 MPa

20 oC

0

0,5

1

1,5

2

0 2 4 6 8 10

0 MPa

140 MPa

120 MPa

90 MPa

Car

ga, k

N

Desplazamiento, mm

a

0

0.5

1

1.5

2

0 2 4 6 8 10

0 MPa

60 MPa

90 MPa

120 MPa

140 MPa

Car

ga, k

N

Desplazamiento, mm

b

0

0.5

1

1.5

2

0 2 4 6 8 10

0 MPa

60MPa

120 MPa

140 MPa

Car

ga, k

N

Desplazamiento, mm

c

150 ppm 500 ppm 1200 ppm

Displacement Displacement Displacement

Loa

d

Loa

d

Load

DUCTILE ONLY FOR REORIENTATION HOOP STRESS LOWER THAN 90 MPA

Page 16: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

16 ENUSA PROPRIETARY - CONFIDENTIAL

Fractographic analysis • Scanning Electron Microscopy analysis of fracture

surface to identify fracture micromechanism has been performed

ductile brittle

Failure criteria

• Three different failure criteria based on strain, plastic deformation and Strain Energy Density has been considered.

Page 17: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

17 ENUSA PROPRIETARY - CONFIDENTIAL

Conclusions • CSN, ENRESA & ENUSA have performed R&D projects

regarding cladding material behaviour during dry storage and transport

• Samples with embrittlement states similar to irradiated material has obtained

• RCT at temperatures representative of storage and transport have been performed

• Circumferential hydrides: the material is ductile, even for 2000 ppm hydrogen and 20oC

• For radial hydrides, hydrogen content, reoriented hydride percentage, and temperature are key parameters

• The results are coherent with other authors published data for non irradiated material

Page 18: Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions · 2015-06-18 · Hydride Effect on Cladding Behaviour for Spent Fuel Storage and Transport Conditions

ENUSA PROPRIETARY - CONFIDENTIAL

www.enusa.es

Thank you for

your attention