hydraulic valves - norgren
TRANSCRIPT
Hydraulic ValvesFind out morewww.norgren.com
All of our products are backed with Norgren's 2-year warranty. Our dedicated team of experts is on hand with technical advice, support and recommendations to help you get the most effective products, in the shortest timescales, and with the best possible service. For ordering information contact your local Norgren Distributor, or Norgren customer service at [email protected], or +1 (860) 677-0272.
In the unlikely event of an item being out of stock, we will ship your item as a priority.
2
4
5
6
3
1Direct Operated Spool Valve32 NWDPFA3 NG3-Mini 36 NWDPFA4 NG4-Mini 39 NWDPFA6 NG6 43 NWDPF65A10 NG10 Pilot Operated Spool Valve47 NVPF90A10 NG10
Manifold Mount05 NB3S NG3-Mini08 NB4S NG4-Mini 12 NA6S NG6 16 NA6S43 4/3 -way NG6 19 NA10S NG10 Cartridge23 NSDSM18 M18 X1.5 ISO 778927 NSDSM22 M22 X1.5 ISO 7789
Cartridge70 NMPM16D M16 x 1.5
Direct Operated Spool Valve52 NWDPU10 - 7/8“-14 UNFPilot Operated Spool Valve56 NWVPM3359 NWVPM42
Cartridge63 NQPU16N 2-way 1 5/16”— 12 UN66 NQPU16D 3-way 1 5/16”— 12 UN
74 NPI29V 77 NE37V79 NE45W81 NE64W83 NS37W85 NE37W
87 NSIS29V89 NSIS35V 91 NSIS45V93 NNSIS45DV-M40 95 NSIS60V97 NS45W
Proportional Directional Control Valves -Manifold Mount
Proportional Directional Control Valves - Cartridge
Poppet Valves
Proportional Flow Control Valves
Proportional Pressure Reducing Valves
Solenoid Coils
Contents
7Proportional Amplifiers 100 NSD7 Digital Amplifier Controller110 NNP2 Digital Amplifier Controller115 NMD2 Digital Amplifier Controller Technical Information 126 Hydraulic Fluids and Filtration 127 Cavity drawings
Electronics & Accessories
Features• Fast response rate
• Leakage free (in closed position)
• 1.5 gpm (6 l/min) to 21 gpm (80 l/min) flow rates at 5000 psi (350 bar)
• 12 and 24v DC control
Norgren’s suite of direct operated 2/2, 3/2 and 4/3 way hydraulic poppet valves are available in both manifold mount and cartridge configurations. Our poppet valves are used for leak free load holding, clamping, gripping, or true 4/3 directional control functionality.
Poppet Valves
Po
pp
et Va
lves
05
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NB3S NG3-Mini Poppet ValveDirect Operated
Technical Data
Description Direct operated 2/2, 3/2 and 3/4-way solenoid poppet valve in sandwich construction. By means of the pressure tight switching solenoid, the poppet valve spool is opened or closed acting against the spring. Due to the poppet spool construction with pressure compensation on both sides, the flow through the valve is possible in both directions. The seat spool guide is sealed by means of an O-ring. The metallically sealing seat closes the valve virtually leak free.
Application Poppet valves are used where tight closing functions of the valve are essential like leakage-free load holding, clamping or gripping. Miniature values are used where both, reduced dimensions and weight are important.
Designation: 2/2, 3/2-way poppet valve
Construction: Direct operated
Operation: Switching solenoid
Mounting: Manifold construction
Mounting Position: Any, preferably horizontal
Fastening Torque: MD = 2.6 Nm (quality 8.8, zinc coated)
Nominal Size: NG3-Mini according to Norgren standard
Weight: 1.01 lb (0.46 kg) 2/2 and 3/2-way 1.58 lb (0.72 kg) 3/4-way
Manual Override: Screw plug (HB0), no actuation possible Optional - HB4.5; HN(K) or HR(K), See data sheet 5.400.041
Seal Material: NBR or FKM (Viton) as standard
Ambient Temperature: -13°….+158°F (-25…+70 °C) NBR -4….+158°F (-20…+70 °C) FKM
MTTFd: 150 years
Protection Class: EN 60 529 IP65
Switching Frequency: 15000/h
Service Lifetime: 107 (number of switching cycles, theoretically)
Voltage Tolerance: ± 10 % with regard to nominal voltage
Solenoid Type: Super, switching solenoid, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 20 / 18 / 14
Filtration: Required filtration grade ß 10…16 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13-+158°F (20…+70 °C)
Flow Direction: Any, See Symbols
Operating Pressure: Super: pmax = 5076 psi (350 bar)
Max. volume flow Min.: Qmax = 1.585 gpm (6 l/min), see characteristic
Leakage Oil: Seat tight, max. 0.05 ml / min (approx. 1 drop / min) at 30 cSt
» Manifold construction » 2/2, 3/2 and 3/4-way » Normally open and normally closed » Qmax = 1.585 gpm (6 l/min) » pmax = 5076 PSI (350 bar)
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 15 watts
Limiting Power 27.1 watts 26.5 watts
Nominal Resitance 10 ohms 40 ohms
Inductivity 17 mH
Number of Windings 740 1490
Total Stroke 2.5 mm
Working Stroke 1 mm
Armature Weight 0.03 lb (0.014 kg)
Weight of Solenoid 2.22 lb (1.0 kg)
See solenoid NSIS29V datasheet in solenoid section of catalogSolenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
06
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NB3S NG3-Mini Poppet ValveDirect Operated
SymbolsNB3S.22b
A
Pa b
a b
NB3S.22aA
Pa b
a b
NB3S.32bA
Pa b
T
a b
NB3S.32aA
Pa b
T
a b
NB3S.34A
Pa
T
a bo ab
Mounting Interface NB
Nominal Size 3-mini 3
Solenoid, Super S
Designation 2-way 2
3-way 3
Switching Positions 2-position 2
4-position 4
Function (Skip if selecting 3/4 )
Normally Open A
Normally Closed B
Nominal Voltage UN 12 VDC 12
24 VDC 24
Sealing Material NBR 1
Configurator
Performance SpecificationsOil viscosity u = 30 mm2/s
∆p = f (Q) Pressure volume flow characteristic
p [bar]
0 1 2 3 4 5 6 Q [l/min]
K00181210
86420
p = f (Q) Performance limits “Medium”Measured with nominal voltage -10%1: 3/2-way valves, flow direction from A → P2: All other valves and flow directions
p [bar]
0 1 2 3 4 5 6 Q [l/min]
K0019
1 2125
100
75
50
25
0
p = f (Q) Performance limits “Super”
Measured with nominal voltage -10%
p [bar]350300250200150100500
00 1 2 3 4 5 6 Q [l/min]
K0017
1234
Flow directionType P - A A - T A - P T - ANB3S22b 1 - 2 -NB3S22a 1 - 3 -NB3S32b 1 2 4 1NB3S32a 1 2 4 1NB3S34 1 1 2 4
Note: Long periods of non-actuation can reduce the switching performance
NB 3 S -1
Po
pp
et Va
lves
07
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NB3S NG3-Mini Poppet ValveDirect Operated
3/2-; 2/2-way
4 42 38 7
100 B.32031a
69
30
29
29
93 B.22031a
7.5
4.3
5.5
2
4.5
MD=
MD=MD= MD=70 40 60105020
30
1.2Nm
2.6Nm
9.5Nm 1.2Nm
A
E
E = Air bleed screw
38
100 B.22030b 100 B.32030b
B
10
35
3/4-way
53
164
A B
10
30 35
3/2-; 2/2-way
Surface Treatment • The valve body is painted with a two component paint • The solenoid and the cover are zinc coated • The socket head screws zinc coated
Commissioning Attention! When commissioning, the valve must be vented under pressure (max. two rotations of screw E).
Dimensions
Hydraulic Connection
T0T
A B
P
10
20
2111
Parts List Position Item # Description
10
20
30
35
40
50
60
70
A209.23133
E209.21101
E209.21102
C426.05103
A016.24141
A016.24109
S200.16145 S600.16145
Solenoid NSIS29V
Screw plug HB0 (incl. seal)
Electric plug A (grey)
Electric plug B (black)
Cover
Socket head screw M3 x 40 DIN 912
Socket head screw M3 x 8 DIN 912
O-ring ID 4.50 x 1.50 (NBR) O-ring ID 4.50 x 1.50 (FKM)
Standards Mounting interface Solenoids Connection execution D Protection class Contamination efficiency
Norgren standard DIN VDE 0580 EN 175301 – 803 EN 60 529 ISO 4406
AccessoriesTechnical explanations Filtration & hydraulic fluidsRelative duty factor
Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Installation Notes
Mounting type
Mounting position
Tightening torque
Manifold mounting 3 mounting holes for socket head screws M4 x 30
Any, preferably horizontal
Assembly screws MD = 2.6 Nm (quality 8.8, zinc coated)
Note: The length of the mounting screw depends on the base MD material of the connection element.
08
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NB4S NG4-Mini Poppet ValveDirect Operated
Factory Automation
Technical Data
Description Direct operated 2/2, 3/2 and 3/4-way solenoid poppet valve in sandwich construction. By means of the pressure tight switching solenoid, the poppet valve spool is opened or closed acting against the spring. Due to the poppet spool construction with pressure compensation on both sides, the flow through the valve is possible in both directions. The seat spool guide is sealed by means of an O-ring. The metallically sealing seat closes the valve virtually leak free.
Application Poppet valves are used where tight closing functions of the valve are essential like leakage-free load holding, clamping or gripping. Miniature values are used where both, reduced dimensions and weight are important.
Designation: 2/2, 3/2-way poppet valve
Construction: Direct operated
Operation: Switching solenoid
Mounting: Manifold construction
Mounting Position: Any, preferably horizontal
Fastening Torque: MD = 5.2 Nm (quality 8.8, zinc coated)
Nominal Size: NG6 according to ISO 4401-03
Weight: 3.96 lb (1.8 kg) 2/2 and 3/2-way 6.17 lb (2.8 kg) 3/4-way
Manual Override: Screw plug (HB0), no actuation possible Optional: HB6; HN(K) or HR(K), see data sheet 5.400.041
Seal Material: NBR or FKM (Viton) as standard
Ambient Temperature: -13°….+158°F (-25…+70 °C) NBR -4….+158°F (-20…+70 °C) FKM
MTTFd: 150 years
Protection Class: EN 60 529 IP65
Switching Frequency: 15000/h
Service Lifetime: 107 (number of switching cycles, theoretically)
Voltage Tolerance: ± 10 % with regard to nominal voltage
Solenoid Type: Super, switching solenoid, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 20 / 18 / 14
Filtration: Required filtration grade ß 10…16 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13-+158°F (20…+70 °C)
Flow Direction: Any, see symbols
Operating Pressure: Super: pmax = 5076 psi (350 bar)
Max. volume flow Min.: Qmax = 1.585 gpm (6 l/min), see characteristic
Leakage Oil: Seat tight, max. 0.05 ml / min (approx. 1 drop / min) at 30 cSt
» Manifold construction » 2/2, 3/2 and 3/4-way » Normally open and normally closed » Qmax = 10.57 gpm (40 l/min) » pmax = 5076 psi (350 bar)
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 22 watts
Limiting Current (50°C)(A) 1.20 A 0.63 A
Limiting Power 13 watts
Nominal Resitance 7.2 ohms 25 ohms
Number of Windings 800 1550
Total Stroke 4 mm
Working Stroke 1.7 mm
Armature Weight 0.052 lb (0.024 kg)
Weight of Solenoid 0.52 lb (0.24 kg)
See solenoid NSIS35V datasheet in solenoid section of catalogSolenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Po
pp
et Va
lves
09
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NB4S NG4-Mini Poppet Valve Direct Operated
SymbolsNB4S.22b
A
Pa b
a b
NB4S.22aA
Pa b
a b
NB4S.32bA
Pa b
T
a b
NB4S.32aA
Pa b
T
a b
NB4S.34A
Pa b
T
a bo ab
Mounting Interface NB
Nominal Size 4-mini 4
Solenoid, Super S
Designation 2-way 2
3-way 3
Switching Positions 2-position 2
4-position 4
Function Normally Open A
Normally Closed B
Nominal Voltage UN 12 VDC 12
24 VDC 24
Sealing Material NBR 1
Configurator NB 4 S -1
10
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NB4S NG4-Mini Poppet Valve Direct Operated
Performance SpecificationsOil viscosity u = 30 mm2/s
∆p = f (Q) Pressure drop volume flow characteristic
40353025201510
50
0 2 4 6 8 10 12 14 16 Q [l/min]
K0154
p [bar]
p = f (Q) Performance limits “Medium”Measured with nominal voltage -10%
160140120100
80604020
00 2 4 6 8 10 12 14 16 Q [l/min]
K0152
p [bar]
p = f (Q) Performance limits “Super”Measured with nominal voltage -10%
350300250200150100
500
0 2 4 6 8 10 12 14 16 Q [l/min]
K0153
p [bar] 1
2345
Flow directionType P - A A - T A - P T - ANB4S22b 1 - 2 -NB4S22a 1 - 4 -NB4S32b 1 3 5 1NB4S32a 1 4 5 1NB4S34 1 1 2 2
Note: Long periods of non-actuation can reduce the switching performance
3/2-; 2/2-way
54 10 59 4
134 B.32041a
38
35
35
76 5
.5
9.5
5.5
32.
5
124 B.22041a
MD=
MD=MD=MD=
E
A
20 1050 70 40 60
30
5.2Nm
2.6Nm2.6Nm9.5Nm
E = Air bleed screw
134 B.22040b 134 B.32040b
54
B
35
10
3/4-way
221
82
A B
30 35
10
3/2-; 2/2-way
Dimensions
Hydraulic Connection
Po
pp
et Va
lves
11
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NB4S NG4-Mini Poppet Valve Direct Operated
Surface Treatment • The valve body is painted with a two component paint • The solenoid and the cover are zinc coated • The socket head screws zinc coated
Commissioning Attention! When commissioning, the valve must be vented under pressure (max. two rotations of screw E).
Standards Mounting interface Solenoids Connection execution D Protection class Contamination efficiency
Norgren standard DIN VDE 0580 EN 175301 – 803 EN 60 529 ISO 4406
Parts List Position Item # Description
10
20
30
35
40
50
60
70
A209.23133
E209.21101
E209.21102
C427.05101
A016.24161
A016.24113
S200.16152 S600.16152
Solenoid NSIS35V
Screw plug HB0 (incl. seal)
Electric plug A (grey)
Electric plug B (black)
Cover
Socket head screw M4 x 60 DIN 912
Socket head screw M4 x 12 DIN 912
O-ring ID 5.28 x 1.78 (NBR) O-ring ID 5.28 x 1.78 (FKM)
Installation Notes Mounting type Manifold mounting 3 mounting holes
for socket head screws M5 x 30
Mounting position Any, preferably horizontal
Tightening torque Assembly screws MD = 5.2 Nm
Note: The length of the mounting screw depends on the base MD material of the connection element.
AccessoriesMounting ScrewsTechnical explanations Filtration & hydraulic fluidsRelative duty factor
Data sheet 5.400.046Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
12
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA6S NG6 Poppet Valve Direct Operated
Factory Automation
Technical Data
Description Direct operated 2/2, 3/2 and 3/4-way solenoid poppet valve in sandwich construction. By means of the pressure tight switching solenoid, the poppet valve spool is opened or closed acting against the spring. Due to the poppet spool construction with pressure compensation on both sides, the flow through the valve is possible in both directions. The seat spool guide is sealed by means of an O-ring. The metallically sealing seat closes the valve virtually leak free.
Application Poppet valves are used where tight closing functions of the valve are essential like leakage-free load holding, clamping or gripping.
Designation: 2/2, 3/2-way poppet valve
Construction: Direct operated
Operation: Switching solenoid
Mounting: Manifold construction
Mounting Position: Any, preferably horizontal
Fastening Torque: MD = 5.2 Nm (quality 8.8, zinc coated)
Nominal Size: NG6 according to ISO 4401-03
Weight: 3.96 lb (1.8 kg) 2/2 and 3/2-way 6.17 lb (2.8 kg) 3/4-way
Manual Override: Screw plug (HB0), no actuation possible Optional: HB6; HN(K) or HR(K), see data sheet 5.400.041
Seal Material: NBR or FKM (Viton) as standard
Ambient Temperature: -13°….+158°F (-25…+70 °C) NBR -4….+158°F (-20…+70 °C) FKM
MTTFd: 150 years
Protection Class: EN 60 529 IP65
Switching Frequency: 15000/h
Service Lifetime: 107 (number of switching cycles, theoretically)
Voltage Tolerance: ± 10 % with regard to nominal voltage
Solenoid Type: Super, switching solenoid, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 20 / 18 / 14
Filtration: Required filtration grade ß 10…16 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13-+158°F (20…+70 °C)
Flow Direction: Any, see symbols
Operating Pressure: Super: pmax = 5076 psi (350 bar)
Max. volume flow Min.: Qmax = 1.585 gpm (6 l/min), see characteristic
Leakage Oil: Seat tight, max. 0.05 ml / min (approx. 1 drop / min) at 30 cSt
» Manifold construction » 2/2, 3/2 and 3/4-way » Normally open and normally closed » Qmax = 10.57 gpm (40 l/min) » pmax = 5076 psi (350 bar)
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 30 watts
Nominal Resitance 5 ohms 21.8 ohms
Inductivity 19 mH 82 mH
Number of Windings 770 1560
Total Stroke 4 mm
Working Stroke 1.7 mm
Armature Weight 0.052 lb (0.044 kg)
Weight of Solenoid 0.52 lb (0.76 kg)
See solenoid NSIS45V datasheet in solenoid section of catalogSolenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Po
pp
et Va
lves
13
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA6S NG6 Poppet Valve Direct Operated
Symbols
NA6S.22b
A
Pa b
a b
NA6S.22a
A
Pa b
a b
NA6S.32b
A
Pa b
T
a b
NA6S.32a
A
Pa b
T
a b
NA6S.34
A
Pa b
T
a bo ab
Mounting Interface NA
Nominal Size NG6 6
Solenoid, Super S
Designation 2-way 2
3-way 3
Switching Positions
2-position 2
4-position 4
Function Normally Open A
Normally Closed B
Nominal Voltage UN
12 VDC 12
24 VDC 24
Sealing Material NBR 1
Configurator NA 6 S -1
14
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA6S NG6 Poppet Valve Direct Operated
Performance SpecificationsOil viscosity u = 30 mm2/s
∆p = f (Q) Pressure drop volume flow characteristic
p [bar]
0 5 10 15 20 25 30 35 40 Q [l/min]
K0078353025201510
50
p = f (Q) Performance limits “Medium”Measured with nominal voltage -10%
Q [l/min]
p [bar]K0077
0 5 10 15 20 25 30 35 40
200
150
100
50
0
p = f (Q) Performance limits “Super”Measured with nominal voltage -10%
350300250200150100500
00 5 10 15 20 25 30 35 40 Q [l/min]
K0127
p [bar]1
234
Flow directionType P - A A - T A - P T - ANA6S.22b 1 - 2 -NA6S.22a 1 - 4 -NA6S.32b 1 2 3 1NA6S.32a 1 2 3 1NA6S.34 1 1 2 2
Note: Long periods of non-actuation can reduce the switching performance
Po
pp
et Va
lves
15
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA6S NG6 Poppet Valve Direct Operated
3/2-; 2/2-way
64 64 15 4
153 A.32061a
45
85
45
9.5
5.5
8
46
38
138 A.22061a
MD=MD= MD=
MD=
E
50 10 70 40 60
30
5.2Nm9.5Nm 5.2Nm
5.2Nm
A
20
E = Air bleed screw
64
153 A.22060b 153 A.32060b
35
B
10
3/4-way
238
90
30 35
A B
10
3/2-; 2/2-wayDimensions
Hydraulic Connection 17.8
21
32.
5
31
40.5
21.5
B
T
P
A
Surface Treatment • The valve body is painted with a two component paint • The solenoid and the cover are zinc coated • The socket head screws zinc coated
Commissioning Attention! When commissioning, the valve must be vented under pressure (max. two rotations of screw E).
Installation Notes
Mounting type
Mounting position
Tightening torque
Manifold mounting 4 mounting holes for socket head screws M5 x 90
Any, preferably horizontal
Assembly screws MD = 9.7 Nm (quality 12.9, zinc coated)
Parts List Position Item # Description
10
30
35
50
70
E209.21101
E209.21102
A016.24171
S200.16193 S600.16192
Solenoid NSIS45V
Electric plug A (grey)
Electric plug B (black)
Socket head screw M5 x 70 DIN 912
O-ring ID 9.25 x 1.78 (NBR) O-ring ID 9.25 x 1.78 (FKM)
AccessoriesMounting ScrewsTechnical explanations Filtration & hydraulic fluidsRelative duty factor
Data sheet 5.400.046Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Note! The length of the mounting screw depends on the base MD material of the connection element.
16
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA6S43 NG6 Poppet Valve Direct Operated
Factory Automation
Technical Data
Description Direct operated 4/3-way solenoid poppet valve in Manifold construction. By means of the pressure tight switching solenoid, the poppet valve spool is opened or closed acting against the spring. Due to the poppet spool construction with pressure compensation on both sides, the flow through the valve is possible in both directions. The seat spool guide is sealed by means of an O-ring. The metallically sealing seat closes the valve virtually leak free.
Application Poppet valves are used where tight closing functions of the valve are essential like leakage-free load holding, clamping or gripping.
Designation: 4/3-way poppet valve
Construction: Direct operated
Operation: Switching solenoid
Mounting: Manifold construction
Mounting Position: Any, preferably horizontal
Fastening Torque: MD = 9.7 Nm (quality 12.9, zinc coated)
Nominal Size: NG6 according to ISO 4401-03
Weight: 11.9 lb (5.4 kg) 4/3-way
Manual Override: Screw plug (HB0), no actuation possible Optional: HB6; HN(K) or HR(K), see data sheet 5.400.041
Seal Material: NBR or FKM (Viton) as standard
Ambient Temperature: -13°….+158°F (-25…+70 °C) NBR -4….+158°F (-20…+70 °C) FKM
MTTFd: 150 years
Protection Class: EN 60 529 IP65
Switching Frequency: 15000/h
Service Lifetime: 107 (number of switching cycles, theoretically)
Voltage Tolerance: ± 10 % with regard to nominal voltage
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Solenoid Type: Super, switching solenoid, wet pin push type, pressure tight
Contamination Efficiency: ISO 4406:1999, Class 20 / 18 / 14
Filtration: Required filtration grade ß 10…16 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: 20…+70 °C. -13-+158°F
Flow Direction: Any, See Symbols
Operating Pressure: Super: pmax = 5076 psi (350 bar)
Max. volume flow Min.: Qmax = 10.57 gpm (40 l/min), see characteristic
Leakage Oil: Seat tight, max. 0.05 ml / min (approx. 1 drop / min) at 30 cSt
» Manifold construction » 4/3-way » Qmax = 10.57 (40 l/min) » pmax = 5076 PSI (350 bar)
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 60 watts
Limiting Power 13 watts
Nominal Resitance 5 ohms 21.8 ohms
Inductivity 10 mH 41mH
Number of Windings 770 1560
Total Stroke 5.5 mm
Working Stroke 2.5 mm
Armature Weight 0.096 lb (0.044 kg)
Weight of Solenoid 3.63 lb (1.65 kg)
See solenoid NSIS45DV datasheet in solenoid section of catalog
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Po
pp
et Va
lves
17
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA6S43 NG6 Poppet Valve Direct Operated
∆p = f (Q) Pressure drop volume flow characteristic
0 5 10 15 20 25 30 35 40 Q [l/min]
K0584
p [bar]50
40
30
20
10
0
P B / P A
A T / B T
p = f (Q) Performance limits “Medium”Measured with nominal voltage -10%
Q [l/min]
p [bar]K0077
0 5 10 15 20 25 30 35 40
200
150
100
50
0
p = f (Q) Performance limits “Super”Measured with nominal voltage -10%
350300250200150100
500
0 5 10 15 20 25 30 35 40 Q [l/min]
K0583
p [bar] P B / A TP A / B T
SymbolA
Pa b
T
a bo
B
Performance CharacteristicsOil viscosity u = 30 mm2/s
Mounting Interface NA
Nominal Size NG6 6
Solenoid, Super S
Designation 4-way
Switching Positions 3-position 3
Nominal Voltage UN 12 VDC 12
24 VDC 24
Sealing Material NBR 1
NA Valve Configurator NA 6 S 4 3 -1
18
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA6S43 NG6 Poppet Valve Direct Operated
4/3-way
72 64 4
220
91
131
92
5.5
9.5
8
84
MD=
MD=
E
EE
E
30 35
50 1020 70
A B5.2Nm
9.5Nm
46
E = Air bleed screw
Surface Treatment • The valve body is painted with a two component paint • The solenoid and the cover are zinc coated • The socket head screws zinc coated
Commissioning Attention! When commissioning, the valve must be vented under pressure (max. two rotations of screw E).
Parts List Position Item # Description
10
30
35
50
70
E209.21101
E209.21102
A016.24171
S200.16193 S600.16192
Solenoid NSIS45DV
Electric plug A (grey)
Electric plug B (black)
Socket head screw M5 x 70 DIN 912
O-ring ID 9.25 x 1.78 (NBR) O-ring ID 9.25 x 1.78 (FKM)
Dimensions Hydraulic Connection 17.8
21
32.
5
31
40.5
21.5
B
T
P
A
AccessoriesMounting ScrewsTechnical explanations Filtration & hydraulic fluidsRelative duty factor
Data sheet 5.400.046Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Installation Notes
Mounting type
Mounting position
Tightening torque
Manifold mounting 4 mounting holes for socket head screws M5 x 90
Any, preferably horizontal
Assembly screws MD = 9.7 Nm (quality 12.9, zinc coated)
Note: The length of the mounting screw depends on the base MD material of the connection element.
Po
pp
et Va
lves
19
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA10S NG10 Poppet Valve Direct Operated
Technical Data
Description Direct operated 2/2, 3/2 and 3/4-way solenoid poppet valve in sandwich construction. By means of the pressure tight switching solenoid, the poppet valve spool is opened or closed acting against the spring. Due to the poppet spool construction with pressure compensation on both sides, the flow through the valve is possible in both directions. The seat spool guide is sealed by means of an O-ring. The metallically sealing seat closes the valve virtually leak free.
Application Poppet valves are used where tight closing functions of the valve are essential like leakage-free load holding, clamping or gripping.
Designation: 2/2, 3/2 and 3/4-way poppet valve
Construction: Direct operated
Operation: Switching solenoid
Mounting: Manifold construction
Mounting Position: Any, preferably horizontal
Fastening Torque: MD = 8.9 Nm (quality 8.8, zinc coated)
Nominal Size: NG10 according to ISO 4401-05
Weight 10.14 lb (4.6 kg) 2/2 and 3/2-way 14.10 (6.4 kg) 3/4-way
Manual Override: Screw plug (HB0),no actuation possible Optional: HB8.5; HN(K) or HR(K), see data sheet 5.400.041
Ambient Temperature: -13°….+158°F (-25…+70 °C) NBR -4….+158°F (-20…+70 °C) FKM
MTTFd: 150 years
Protection Class: EN 60 529: IP65
Service Lifetime: 107 (number of switching cycles, theoretically)
Switching Frequency: 15000/h
Voltage Tolerance: ± 10 % with regard to nominal voltage
Solenoid Type: Super, switching solenoid, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Viscosity Range: 12 mm2/s to 320 mm2/s
Seal Material: NBR or FKM (Viton) as standard
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 20 / 18 / 14
Filtration: Required filtration grade ß 10…16 ≥ 75
Fluid Temperature: -13-+158 °F (20…+70 °C)
Flow Direction: Any, See characteristic
Operating Pressure: Super: pmax = 5076 psi (350 bar)
Max. volume flow: Qmax = 21.14 gpm (80 l/min), see characteristic
Leakage Oil: Seat tight, max. 0,05 ml / min (approx. 1 drop / min) at 30 cSt
» Manifold construction » 2/2, 3/2 and 3/4-way » Normally open and normally closed » Qmax = 21.14 gpm (80 l/min) » pmax = 5076 psi 350 bar
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 40 watts
Limiting Power 13 watts
Nominal Resitance 4 ohms 16.5 ohms
Inductivity 17 mH 65 mH
Number of Windings 780 1580
Total Stroke 8.5 mm
Working Stroke 4 mm
Armature Weight 0.22 lb (0.102 kg)
Weight of Solenoid 4.19 lb (1.9 kg)
See solenoid NSIS60V datasheet in solenoid section of catalog
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
20
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA10S NG10 Poppet Valve Direct Operated
SymbolsNA10S.22b
A
Pa b
a b
NA10S.22aA
Pa b
a b
NA10S.32bA
Pa b
T
a b
NA10S.32aA
Pa b
T
a b
NA10S.34A
Pa b
T
a bo ab
Mounting Interface NA
Nominal Size 10 10
Solenoid, Super S
Designation 2-way 2
3-way 3
Switching Positions 2-position 2
4-position 4
Function Normally Open A
Normally Closed B
Nominal Voltage UN 12 VDC 12
24 VDC 24
Sealing Material NBR 1
Configurator NA 10 -1
NA10S.22bA
Pa b
a b
NA10S.22aA
Pa b
a b
NA10S.32bA
Pa b
T
a b
NA10S.32aA
Pa b
T
a b
NA10S.34A
Pa b
T
a bo ab
NA10S.22bA
Pa b
a b
NA10S.22aA
Pa b
a b
NA10S.32bA
Pa b
T
a b
NA10S.32aA
Pa b
T
a b
NA10S.34A
Pa b
T
a bo ab
Po
pp
et Va
lves
21
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA10S NG10 Poppet Valve Direct Operated
∆p = f (Q) Pressure drop volume flow characteristic
0 10 20 30 40 50 60 70 80 Q [l/min]
K0157
p [bar]20
15
10
5
0
Flow directionType P - A A - T A - P T - ANA10S.22a 1 - 4 -NA10S.22b 1 - 2 -NA10S.32a 1 3 5 1NA10S.32b 1 3 3 1NA10S.34 1 1 4 4
p = f (Q) Performance limits “Super”Measured with nominal voltage -10%
350300250200150100
500
0 10 20 30 40 50 60 70 80 Q [l/min]
K0156
p [bar] 3 2 1
Note: Long periods of non-actuation can reduce the switching performance
Performance CharacteristicsOil viscosity u = 30 mm2/s
22
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NA10S NG10 Poppet Valve Direct Operated
3/2-; 2/2-way
60
4 81 93 18
198 A.32101a
60
62
10
1
180 A.22101a
7
10.5
6.5
55
MD=
MD= MD=
E
70 60401050
20
30
8.9Nm 8.9Nm
8.9NmA
E = Air bleed screw
93
198 A.22100b 198 A32100b
35B
10
3/4-way
133
307
30 35A B
10
3/2-; 2/2-way
Surface Treatment • The valve body is painted with a two component paint • The solenoid and the cover are zinc coated • The socket head screws zinc coated
Dimensions
Hydraulic Connection
46
54
1.5
16.
8
9.7
20.8
24
A B
P
T To
Parts List Position Item # Description
10
20
30
35 4050
60
70
E209.21101
E209.21102
E229.05100 C316.24190 A316.24121
S210.16140
S610.16141
Solenoid NSIS60V
Screw plug HB0 (incl. seal)
Electric plug A (grey)
Electric plug B (black) Cover
Socket head screw M6 x 90 DIN 912 Socket head screw M6 x 20 DIN 912
O-ring ID 14.00 x 1.78 (NBR) O-ring ID 14.00 x 1.78 (FKM)
Commissioning Attention! When commissioning, the valve must be vented under pressure (max. two rotations of screw E).
AccessoriesMounting ScrewsTechnical explanations Filtration & hydraulic fluidsRelative duty factor
Data sheet 5.400.046Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Installation Notes
Mounting type
Mounting position
Tightening torque
Manifold mounting 4 mounting holes for socket head screws M5 x 65
Any, preferably horizontal
Assembly screws MD = 8.9 Nm (quality 8.8, zinc coated)
Note: The length of the mounting screw depends on the base MD material of the connection element.
Po
pp
et Va
lves
23
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSDSM18 Poppet Valve M18 X1.5 ISO 7789 Direct Operated
» Solenoid operated poppet valve cartridge » Direct operated » 2/2 and 3/2-way » Qmax = 10.568 gpm (40 l/min) » pmax = 5076 psi (350 bar)
Technical DataDesignation: 2/2, 3/2-way poppet valve
Construction: Direct operated
Operation: Switching solenoid
Mounting: Screw-in cartridge construction
Mounting Position: Any, preferably horizontal
Fastening Torque: MD = 40 Nm Screw-in cartridge MD = 5 Nm knurled nut MD = 9.5 Nm HB0 MD = 5.5 Nm HB4.5
Nominal Size: M18 x 1.5 according to ISO
Weight: 1.01 lbs (0,46 kg) 2/2-way 1.05 lbs (0,48 kg) 3/2-way
Manual Override: Screw plug (HB0), no actuation possible Optionally - HB4.5; HN(K) or HR(K), see data sheet 1.1-311
Ambient Temperature: -13-+158°F (20…+70 °C)
MTTFd: 150 years
Switching Frequency: 5000/h
Service Lifetime: 107 (number of switching cycles, theoretically)
Voltage Tolerance: ± 10 % with regard to nominal voltage
Solenoid Type: Switching Solenoid, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Seal Material: NBR or FKM (Viton) as standard
Filtration: Required filtration grade ß 10…16 ≥ 75
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 20 / 18 / 14
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13°….+158°F (-25…+70 °C ) NBR -4….+158°F (-20…+70 °C) FKM -40…+158°F (-40…+70 °C) NBR 872 (Z604)
Flow Direction: Any, see symbols
Operating Pressure: Super: pmax = 5076 psi (350 bar)
Max. volume flow: Qmax = 10.566 gpm (40 l/min), see characteristic
Leakage Oil: Seat tight, max. 0.15 ml/min (approx. 3 drops / min) at 30 cSt
Description Direct operated 2/2 and 3/2-way solenoid poppet valve in screw-in cartridge construction for cavity according to ISO 7789 / Norgren standard. By means of the pressure tight switching solenoid, the pressure compensated, metallically sealing poppet spool is either opened or closed. The seat spool guide is sealed by means of an O-ring).
Application Norgren solenoid operated poppet valve cartridges are used where tight closing functions are essential like leakage-free load holding, clamping or gripping. For machining the cartridge cavity in steel and aluminum blocks, cavity tools are available (hire or purchase). Please refer to cavity data sheets listed under hydraulic connection.
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 20.5 watts
Limiting Current 1.20 A 0.63 A
Limiting Power 22 watts
Nominal Resistance 6.4 ohms 27.2 ohms
Number of Windings 780 1560
Weight of Solenoid 0.44 lb (0.20 kg)
See solenoid NE37V datasheet in solenoid section of catalog
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
24
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSDSM18 Poppet Valve M18 X1.5 ISO 7789 Direct Operated
Symbols*“Normally open“ AB
2
1a b
“Normally closed“ BA
2
1a b
FG2
3 1a b
NS D S M18 - 1Poppet Valve NS
Directly Operated D
Solenoid, Super S
Screw-in cartridge M18 x 1.5 M18
Symbol Code*
Nominal Voltage UN
12 VDC 12
24 VDC 24
Without Coil* X5
ConnectionExecution (Skip if X5)
EN 175301 – 803 NE37VD/19x50 D
Deutsch DT04 – 2P NE37VG/19x50 G
Slip-on Coil (Skip if X5) Metal housing round with one-sided collar V
Sealing Material NBR 1
Configurator
Note: Use symbol codes above for part number configurator.
* For ordering information please see Solenoid Coils section of this catalog, NE37V
Po
pp
et Va
lves
25
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSDSM18 Poppet Valve M18 X1.5 ISO 7789 Direct Operated
Performance SpecificationsOil viscosity u = 30 mm2/s
p = f (Q) Performance limit AB / BAMeasured with nominal voltage -10%
K4238
p [bar]
Q [l/min]25 35302015100 5 40
350300250200150100
500
1
23
Flow directionExecution 1 → 2 2 → 1NSDSM18-AB 3 1NSDSM18-BA 2 1
p = f (Q) Performance limit FGMeasured with nominal voltage -10%
K4239
p [bar]
Q [l/min]12,5 17,515107,550 2,5 20
350300250200150100
500
1
23
Flow directionExecution 1 → 2 2 → 1 2 → 3 3 → 2NSDSM18-FG 3 1 1 2
∆p = f (Q) Pressure drop volume flow characteristics
K4240
∆p [bar]
Q [l/min]12,5 17,515107,550 2,5 20
3025201510
50
1
2
34
Flow directionExecution 1 → 2 2 → 1 2 → 3 3 → 2NSDSM18-AB 4 4 - -NSDSM18-BA 3 3 - -NSDSM18-FG 2 2 1 1
The switching times depend on the volume flow, pressure and viscosity. In case of very large volume flows, the switching time for closing can get considerably longer.
-
NSDSM18
Switching times
Type Flow direction Switching on Switching off
AB 1 → 22 → 1
approx. 40 msapprox. 40 ms
approx. 20 msapprox. 10 ms
BA 1 → 22 → 1
approx. 40 msapprox. 30 ms
approx. 30 msapprox. 30 ms
FG 1 → 22 → 12 → 33 → 2
approx. 40 msapprox. 40 msapprox. 40 msapprox. 40 ms
approx. 10 msapprox. 10 msapprox. 40 msapprox. 20 ms
Note:
26
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSDSM18 Poppet Valve M18 X1.5 ISO 7789 Direct Operated
SDSPM18-AB / BA
MD=5Nm
V=
37
84.9 31 (AB) 29.5 (BA)
122.1 (AB) 120.6 (BA)
76
MD= 9.5Nm s24
(2)(1)
M18
x1.5
E
15
12 17 10 50 70 60
N=
35
74.
8
10
MD=5.5Nm
HB4.5
15
SDSPM18-FG
V=
37
84.9 46.1
137.2
76
(3) (2)(1)
s24
M18
x1.5
8090
AccessoriesTechnical explanations Filtration & hydraulic fluidsRelative duty factor
Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.43
Surface Treatment The cartridge body, the slip-on coil and the armature tube are zinc-nickel coated
Dimensions
Parts List Position Item # Description
10 12
15
17
50
60
70
80
90
C274.15100 A803.25100 A209.23133 S210.16187 S210.16156 S610.16156 S210.16111 S610.16111 S819.04137 S200.16193 S600.16192
S819.04156
NE37V / 19 x 50 Knurled nut
HB4,5 manual override HB0 Screw plug
O-ring ID 18.72 x 2.62 (NBR) O-ring ID 15.60 x 1.78 (NBR) O-ring ID 15.60 x 1.78 (FKM) O-ring ID 11.11 x 1.78 (NBR) O-ring ID 11.11 x 1.78 (FKM)
Back-up ring PTSM rd 8.7 x 11.6 x 1.4 O-ring ID 9.25 x 1.78 (NBR) O-ring ID 9.25 x 1.78 (FKM)
Back-up ring PTSM rd 10.1 x 13 x 1.4
Hydraulic ConnectionCavity drawing according to ISO 7789–18–01–0–98
Cavity drawing according to standard
(2)
(1)
(1)
M18x1 .5
(1)
(3)
(2)
(1)
M18x1 .5
StandardsCartridge cavity Solenoids Connection execution D Protection class Contamination efficiency
ISO 7789 / Norgren standard DIN VDE 0580 EN 175301 – 803 EN 60 529 ISO 4406
Installation Notes Mounting type Mounting position
Tightening torque
Screw-in cartridge M18 x 1.5 Any, preferably horizontal MD = 40 Nm Screw-in cartridge MD = 5 Nm knurled nut MD = 9.5 Nm HB0 MD = 5.5 Nm HB4.5
For detailed cavity drawing and cavity tools see datasheet 5.400.035
For detailed cavity drawing and cavity tools see datasheet 5.400.049
Po
pp
et Va
lves
27
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSDSM22 Poppet Valve M22 X1.5 ISO 7789 Direct Operated
» Solenoid operated poppet valve cartridge » Direct operated » 2/2 and 3/2-way » Qmax = 10.568 gpm (40 l/min) » pmax = 5076 psi (350 bar)
Technical Data
Description Direct operated 2/2 and 3/2-way solenoid poppet valve in screw-in cartridge construction for cavity according to ISO 7789. By means of the pressure tight switching solenoid, the pressure compensated, metallically sealing poppet spool is either opened or closed. The seat spool guide is sealed by means of an O-ring.
Application Norgren solenoid operated poppet valve cartridges are used where tight closing functions are essential like leakage-free load holding, clamping or gripping. For machining the cartridge cavity in steel and aluminum blocks, cavity tools are available (hire or purchase). Please refer to cavity data sheets listed under hydraulic connection.
Designation: 2/2, 3/2-way poppet valve
Construction: Direct operated
Operation: Switching solenoid
Mounting: Screw-in cartridge construction
Mounting Position: Any, preferably horizontal
Fastening Torque: MD = 60 Nm Screw-in cartridge MD = 5 Nm knurled nut MD = 9.5 Nm HB0 MD = 5.5 Nm HB4.5
Nominal Size: M22 x 1.5 according to ISO 7789
Weight: 1.23 (0.56 kg) 2/2-way 1.32 (0.60 kg) 3/2-way
Manual Override: Screw plug (HB0), no actuation possible Optionally - HB4.5; HN(K) or HR(K), see data sheet 1.1-311
Ambient Temperature: -13-+158°F (20…+70 °C)
MTTFd: 150 years
Switching Frequency: 5000/h
Service Lifetime: 107 (number of switching cycles, theoretically)
Voltage Tolerance: ± 10 % with regard to nominal voltage
Solenoid Type: Switching Solenoid, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Seal Material: NBR or FKM (Viton) as standard
Filtration: Required filtration grade ß 10…16 ≥ 75
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 20 / 18 / 14
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13°….+158°F (-25…+70 °C ) NBR -4….+158°F (-20…+70 °C) FKM
Flow Direction: Any, See Symbols
Operating Pressure: Super: pmax = 5076 psi (350 bar)
Max. volume flow: Qmax = 10.566 gpm (40 l/min), see characteristic
Leakage Oil: Seat tight, max. 0.15 ml/min (approx. 3 drops / min) at 30 cSt
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 20.5 watts
Limiting Current 1.20 A 0.63 A
Limiting Power 22 watts
Nominal Resistance 6.4 ohms 27.2 ohms
Number of Windings 780 1560
Weight of Solenoid 0.44 lb (0.20 kg)
See solenoid NE37V datasheet in solenoid section of catalog
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
28
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSDSM22 Poppet Valve M22 X1.5 ISO 7789 Direct Operated
Configurator
Symbols*“Normally open“ AB
2
1a b
“Normally closed“ BA2
1a b
FG2
3 1a b
NS D S M22 - 1
Note: Use symbol codes above for part number configurator.
Poppet Valve NS
Directly Operated D
Solenoid, Super S
Screw-in cartridge M22 x 1.5 M22
Symbol Code*
Nominal Voltage UN
12 VDC 12
24 VDC 24
Without Coil* X5
ConnectionExecution (Skip if X5)
EN 175301 – 803 NE37VD/19x50 D
Deutsch DT04 – 2P NE37VG/19x50 G
Slip-on Coil (Skip if X5) Metal housing round with one-sided collar V
Sealing Material NBR 1
* For ordering information please see Solenoid Coils section of this catalog, NE37V
Po
pp
et Va
lves
29
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSDSM22 Poppet Valve M22 X1.5 ISO 7789 Direct Operated
Performance SpecificationsOil viscosity u = 30 mm2/s
p = f (Q) Performance limit FGMeasured with nominal voltage -10%
K4192
p [bar]
Q [l/min]15 17.512.5107.50 52.5 20
350300250200150100
500
123
Flow directionExecution 1 → 2 2 → 1 2 → 3 3 → 2NSDSM22-FG 2 1 1 3
∆p = f (Q) Pressure drop volume flow characteristics
K4193
p [bar]
Q [l/min]30 352520150 5 10 40
40353025201510
50
1
23
4
Flow directionExecution 1 → 2 2 → 1 2 → 3 3 → 2NSDSM22-AB 3 4 - -NSDSM22-BA 2 2 - -NSDSM22-FG 3 4 1 1
Swichting times
NSDSM22
Type Flow direction Switching on Switching off
AB
1 → 22 → 1
approx. 40 msapprox. 40 ms
approx. 20 msapprox. 10 ms
BA
1 → 22 → 1
approx. 30 msapprox. 40 ms
approx. 30 msapprox. 30 ms
FG
1 → 22 → 12 → 33 → 2
approx. 40 msapprox. 40 msapprox. 40 msapprox. 40 ms
approx. 10 msapprox. 10 msapprox. 40 msapprox. 20 ms
The switching times depend on the volume flow, pressure and viscosity. In case of very large volume flows, the switching time for closing can get considerably longer.
p = f (Q) Performance limit AB / BAMeasured with nominal voltage -10%
K4191
p [bar]
Q [l/min]30 352520150 105 40
350300250200150100
500
1
2
3
4
Flow directionExecution 1 → 2 2 → 1NSDSM22-AB 4 2NSDSM22-BA 3 1
Note:
30
Po
pp
et Va
lves
1
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSDSM22 Poppet Valve M22 X1.5 ISO 7789 Direct Operated
SDSPM22-AB / BA
V =
37
84.9 40 (AB) 37.1 (BA)
131.1 (AB) 128.2 (BA)
76
MD=5Nm
MD= 9.5Nm
E
s27
M22
x1.5
15
12 17 10 50 6070
(2)
(1)
N =
35
74.
8
10
MD=5.5Nm15
HB4,5
SDSPM22-FG
V =
37
84.9 60.6
151.7
76
s27
M22
x1.5
8090
(2)
(1)
(3)
Installation Notes Mounting type Screw-in cartridge M22 x 1.5
Mounting position Any, preferably horizontal
MD= 60 Nm Screw-in cartridge
Tightening torque MD = 5 Nm knurled nut MD = 9.5 Nm HB0 MD = 5.5 Nm HB4.5
Surface Treatment The cartridge body, the slip-on coil and the armature tube are zinc-nickel coated
Dimensions
Standards Cartridge cavity
Solenoids
Connection execution D
Protection class
Contamination
ISO 7789
DIN VDE 0580
EN 175301 – 803
EN 60 529
ISO 4406
Parts List Position Item # Description
10
12
15
17
50
60
70
80
90
C274.15100 A803.25100 A209.23133 S210.16187 S210.16188 S610.16188 S210.16156 S610.16156
S819.04196 S210.16140 S610.16141
S819.04156
NE37V / 19 x 50
Knurled nut HB4,5 manual override
HB0 Screw plug O-ring ID 18.72 x 2.62 (NBR) O-ring ID 18.77 x 1.78 (NBR) O-ring ID 18.77 x 1.78 (FKM) O-ring ID 15.60 x 1.78 (NBR) O-ring ID 15.60 x 1.78 (FKM)
Backup ring PTSM rd 14.5 x 17.4 x 1.4 O-ring ID 14.00 x 1.78 (NBR) O-ring ID 14.00 x 1.78 (FKM)
Back-up ring PTSM rd 12.7 x 15.6 x 1.4
Hydraulic ConnectionCavity drawing according to ISO 7789–22–01–0–98
Cavity drawing according to standard
For detailed cavity drawing and cavity tools see datasheet 5.400.036
For detailed cavity drawing and cavity tools see datasheet 5.400.037
AccessoriesTechnical explanations Filtration & hydraulic fluidsRelative duty factor
Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.43
Norgren’s broad range of proportional directional control manifold mount valves, feature robust and precise construction for low leakage, hysteresis and reliable operation. Their linear volume flow pressure characteristics allow for precise and repeatable speed and linear actuation control in industrial and mobile applications.
Features
• Direct and pilot operated options
• Linear flow control characteristics
• Low hysteresis ≤ 7%
• Low leakage oil characteristics
• 13 gpm (10 l/min) to 23 gpm (90 l/min) flow rates at 5000 psi (350 bar)
Proportional Directional Control Valves - Manifold Mount
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
32
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA3 NG3-Mini Proportional Spool Valve Direct Operated » Manifold construction » Qmax = 2.64 gpm (10 l/min) » 3 volume flow levels » QN max = 13.47 gpm (5 l/min) » Pmax = 5076 psi (350 bar)
Technical DataDesignation: Proportional spool valve
Construction: Direct operated
Operation: Proportional Solenoid
Mounting:Manifold construction
Mounting Position: Any, preferably horizontal
Fastening Torque: MD = 2.6 Nm (quality 8.8, zinc coated)
Nominal Size: NG3-Mini according to Norgren standard
Weight: 1.10 lbs (0.50 kg) 1 solenoid 1.43 lbs (0.65 kg) 2 solenoids
Manual Override: Screw plug with integrated manual override (HB4.5) Actuation by pressing the push button
Seal Material: NBR or FKM (Viton) as standard
Ambient temperature -13 to +158 °F (-25…+70 °C) if » 122 °F (50 °C), IG is only conditionally achievable
MTTFd: 150 years
Solenoid Type: Proportional Solenoid, wet pin push type, Class H, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 18 / 16 / 13
Filtration: Required filtration grade ß 6…10 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13°….+158 °F ( -25…+70 °C) NBR -4….+158°F (-20…+70 °C) FKM
Tank Pressure: pT Max= 1450 psi (100 bar)
Operating Pressure: pmax = 5076 psi (350 bar), PT = < 290 psi (20 bar) pmax = 4568 psi (315 bar), PT = » 290 psi (20 bar)
Max. Volume Flow : Qmax = 2.64 gpm (10 l/min), see characteristic
Nominal Volume: QN= 0.26; 0.52; 1.32 gpm (1 ; 2; 5 l/min)
Leakage Oil: See characteristics
Hysteriisis: < 5% at optimal dither signal
Description Direct operated proportional spool valve with 4 connections in 5-chamber system. Precise spool fit, low leakage, long service lifetime. The volume flow adjustment takes place by a Norgren proportional solenoid. Proportional to the solenoid current, the spool stroke, the spool opening and the valve volume flow increase. For the control, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional spool valves are ideally suited for demanding tasks due to the high resolution, large volume flow and low hysteresis. For use in industrial and mobile hydraulics applications for the smooth control of hydraulic actuators. Some examples: rotor blades control of wind generators, forestry and earth moving machines, machine tools and paper production machines with simple position control, robotics and fan control. Miniature valves are used where both, reduced dimensions and weight are important.
Solenoid Coil Electrical Specifications:Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 8.1 watts 8.8 watts
Limiting Current (50°C) 1.08 A 0.54 A
Limiting Power 13 watts
Nominal Resitance 3.7 ohms 15.2 ohms
Inductivity 12 mH 45
Number of Windings 645 1310
Total Stroke 2.5 mm
Working Stroke 1 mm
Armature Weight 0.03 lb (0.014 kg)
Weight of Solenoid 0.46 lb (0.21 kg)
See solenoid NPI29V datasheet in solenoid section of catalog
Solenoid Coil Connection:
Connector Type Standard Protection Class
DIN EN 175301 – 803 D: IP 65
33
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA3 NG3-Mini Proportional Spool Valve Direct Operated
Symbols*
P T
BA
aa
bb0
ACBS
P T
BA
aa
b
AC1S
P T
BA
a bb
CB2S
Meter-in control
Symmetrical Control
ADBV AD1V
P T
BA
a bb
DB2V
P T
BA
baa b
P T
BA
aa
b
Configurator NW D P F A3 5 1Spool Valve NW
Directly Operated D
Proportional P
Manifold Construction F
Mounting Interface Acc. to NG3-mini A3
Symbol Code*
Nominal Volume flow rate QN 5 l/min 5
Nominal Voltage UN 12 VDC 12
24 VDC 24
Sealing Material NBR 1
P T
BA
aa
bb0
ACBS
P T
BA
aa
b
AC1S
P T
BA
a bb
CB2S
Meter-in control
Symmetrical Control
ADBV AD1V
P T
BA
a bb
DB2V
P T
BA
baa b
P T
BA
aa
b
Note: Use symbol codes above for part number configurator.
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
34
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA3 NG3-Mini Proportional Spool Valve Direct Operated
Performance SpecificationsOil viscosity u = 30 mm2/s
Q = f (p) Volume flow pressure characteristicsI = IG
ACB-S, AC1-S, CB2-S
1210
86420
0 50 100 150 200 250 300 350 p [bar]
K1189
Q [l/min]
QN = 5 l/min
QN = 2 l/minQN = 1 l/min
Q = f (p) Volume flow pressure characteristicsI = IG
ADB-V, AD1-V, DB2-V
1210
86420
0 50 100 150 200 250 300 350 p [bar]
K1190
Q [l/min]
QN = 5 l/min
QN = 2 l/min
QN = 1 l/min
∆p = f (Q) Volume flow pressure characteristicsI = IG
ACB-S, AC1-S, CB2-S
Q [l/min]
K1191
p [bar]
QN = 5 l/min605040302010
00 2 4 6 8 10
QN = 1 l/min QN = 2 l/min
∆p = f (Q) Volume flow pressure characteristicsI = IG
ADB-V, AD1-V, DB2-V
Q [l/min]
K1192
p [bar]
QN = 5 l/min
605040302010
00 2 4 6 8 10
QN = 1 l/min QN = 2 l/min
Q = f (I) Volume flow adjustment characteristics∆p = 10 barACB-S, AC1-S, CB2-S
0 10 20 30 40 50 60 70 80 90 100
K1193
Q [l/min]6543210
I [%]
QN = 5 l/min
QN = 2 l/min
QN = 1 l/min
Q = f (I) Volume flow adjustment characteristics∆p = 10 barADB-V, AD1-V, DB2-V
0 10 20 30 40 50 60 70 80 90 100
K1194
Q [l/min]6543210
I [%]
QN = 5 l/min
QN = 2 l/min
QN = 1 l/min
QL = f (p) Leakage volume flow characteristics
8070605040302010
00 50 100 150 200 250 300 350 p [bar]
K1195
Q [cm 3/min]
Note: All values were measured over two control edges. The connections A and B were short-circuited.
35
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA3 NG3-Mini Proportional Spool Valve Direct Operated
149
A B
30 35
30
29
29
70
42 38 7
101
3
5
25
7.5
4.2
M D= M D= M D=
A
1020 50 70 605.2Nm 1.2Nm 1.2Nm
30
Parts List Position Article Description
10 NPI29V-G24 Proportional solenoid 24 volts NPI29V-G12 Proportional solenoid 12 volts
20 A803.25100 Screw plug with integrated manual override
HB4.5 (Data sheet 5.400.039)
30 E209.21101 Electric plug A (grey)
35 E209.21102 Electric plug B (black)
50 A016.24141 Socket head screw M3 x 40 DIN 912
60 A016.24109 Socket head screw M3 x 8 DIN 912
70 S200.16145 O-ring ID 4.50 x 1.50 (NBR),
preferably horizontal
Installation Notes Manifold mounting Mounting type 3 Mounting holes for socket head screws M4 x 30
Mounting position Any, preferably horizontal
Tightening torque MD= 2.6 Nm (quality 8.8) mounting screws
Note: The length of the mounting screw depends on the base material of the connection element.
Surface Treatment • The valve body is painted with a two component paint • The solenoid and the cover are re zinc-nickel coated • The socket head screws are zinc coated
Dimensions
Hydraulic Connection
T0T
A B
P
10
20
2111
AccessoriesProportional amplifier Technical explanations Filtration & hydraulic fluidsRelative duty factor
NPD2, NSD7, NMD2Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
36
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA4 NG4-Mini Proportional Spool Valve Direct Operated
» Manifold construction » Qmax = 5.28 gpm (20 l/min) » 3 volume flow levels » QN max = 3.17 gpm (12 l/min) » Pmax = 5076 psi (350 bar)
Technical DataDesignation: Proportional spool valve
Construction: Direct operated
Mounting: Manifold construction
Nominal size: NG4-Mini according to Norgren standard
Actuation: Proportional solenoid
Ambient temperature: -13 to +158 °F (-25…+70 °C) NBR -4 to +158 °F (-20…+70 °C) FKM if » 122 °F (50 °C), IG is only conditionally achievable
Weight: 1.98 lbs (0.90 kg) 1 solenoid 2.75 lbs (1.25 kg) 2 solenoids
MTTFd: 150 years
Seal Material: NBR or FKM (Viton) as standard
Solenoid Type: Proportional Solenoid, wet pin push type, Class H, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 18 / 16 / 13
Filtration: Required filtration grade ß 6…10 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -25…+70 °C , -13°….+158°F (NBR) -20…+70 °C, -4….+158°F (FKM)
Max. Volume Flow : Qmax = 5.284 gpm (20 l/min), see characteristics
Operating Pressure: pmax = 5075 psi (350 bar), PT = < 290 psi (20 bar) pmax = 4,568 psi (315 bar), PT = » 290 psi (20 bar)
Tank Pressure: PT Max= 2320 psi (160 bar)
Nominal Volume: QN= 1.057; 2.114; 3.17 gpm (4; 8; 12 l/min)
Leakage Oil: See characteristics
Hysterisis: < 5% at optimal dither signal
Description Direct operated proportional spool valve with 4 connections in 5-chamber system. Precise spool fit, low leakage, long service lifetime. The volume flow adjustment takes place by a Norgren proportional solenoid. Proportional to the solenoid current, the spool stroke, the spool opening and the valve volume flow increase. For the control, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional spool valves are ideally suited for demanding tasks due to the high resolution, large volume flow and low hysteresis. For use in industrial and mobile hydraulics applications for the smooth control of hydraulic actuators. Some examples: rotor blades control of wind generators, forestry and earth moving machines, machine tools and paper production machines with simple position control, robotics and fan control. Miniature valves are used wher both, reduced dimensions and weight are important.
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 20.5 watts
Limiting Current (50°C)(A) 1.20 A 0.63 A
Limiting Power 22 watts
Nominal Resitance 6.4 ohms 27.2 ohms
Number of Windings 780 1560
Weight of Solenoid 0.44 lb (0.20 kg)
See solenoid NE37V datasheet in solenoid section of catalog
Solenoid Coil Connection:
Connector Type Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
Symbols*
P T
BA
aa
bb0
ACBS
P T
BA
aa
b
AC1S
P T
BA
a bb
CB2S
Meter-in control
Symmetrical control
P T
BA
aa
bb0
ACBV
P T
BA
aa
b
AC1V
P T
BA
a bb
CB2V
Meter-in controlADBV AD1V
P T
BA
a bb
DB2V
P T
BA
baa b
P T
BA
aa
b
Meter-out control
P T
BA
aa
bb0
ACBR
P T
BA
aa
b
AC1R
P T
BA
a bb
CB2R
P T
BA
aa
bb0
ACBS
P T
BA
aa
b
AC1S
P T
BA
a bb
CB2S
Meter-in control
Symmetrical control
P T
BA
aa
bb0
ACBV
P T
BA
aa
b
AC1V
P T
BA
a bb
CB2V
Meter-in controlADBV AD1V
P T
BA
a bb
DB2V
P T
BA
baa b
P T
BA
aa
b
Meter-out control
P T
BA
aa
bb0
ACBR
P T
BA
aa
b
AC1R
P T
BA
a bb
CB2R
Note: Use symbol codes above for part number configurator.
37
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA4 NG4-Mini Proportional Spool Valve Direct Operated
Configurator NW D P FA4 12 - 1 NSpool Valve NW
Directly Operated D
Proportional P
Manifold Construction F
Mounting Interface Acc. to NG4-mini A4
Symbol Code*
Nominal Volume flow rate QN 12 l/min 12
Nominal Voltage UN 12 VDC 12
24 VDC 24
Without Coil* X5
Slip-on Coil (Skip if X5)
V Metal housing, round with one-sided collar
Connection (Skip if X5)
D Connector socket EN 175301-803 / ISO 440
G Connector deutsch DT04-2P
Sealing Material
1 NBR
Manual Overide
N Integrated
Performance SpecificationsOil viscosity u = 30 mm2/s
Q = f (p ) Volume flow pressure characteristicsI =IG
ACB-S, AC1-S, CB2-S
Q = f (I) Volume flow adjustment characteristicsΔp = 10 barACB-V, AC1-V, CB2-V, ADB-V, AD1-V, DB2-V
Δp = f (Q ) Pressure drop volume flow characteristicsI =IG
ACB-S, AC1-S, CB2-S
Q = f (p ) Volume flow pressure characteristicsI =IG
ACB-R, AC1-R, CB2-R
Q = f (I) Volume flow adjustment characteristics∆p = 10 barACB-S, AC1-S, CB2-S
Δp = f (Q) Pressure drop volume flow characteristicsI =IG
ACB-R, AC1-R, CB2-R
Q = f (p) Volume flow pressure characteristicsI =IG
ACB-V, AC1-V, CB2-V, ADB-V, AD1-V, DB2-V
Q = f (I) Volume flow adjustment characteristicsΔp = 10 barACB-R, AC1-R, CB2-R
Δp = f(Q) Pressure drop volume flow characteristicsI =IG
ACB-V, AC1-V, CB2-V, ADB-V, AD1-V, DB2-V
* For ordering information please see Solenoid Coils section of this catalog, NE37V
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
38
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA4 NG4-Mini Proportional Spool Valve Direct Operated
193
A B
30
43
80
HF1
30
44
90
HS1 133
8 57 50 18
V =
37
38
32
6
77
5.2
9.5 A
M D=
M D=
501070 60
5.2Nm
5Nm
133
15 53
N =
35
77
A
10
Installation Notes Manifold mounting Mounting type 3 Mounting holes for socket head screws M4 x 40
Mounting position Any, preferably horizontal
Tightening torque MD= 5.2 Nm (quality 8.8) mounting screws MD = 5 Nm knurled nut
Note: The length of the mounting screw depends on the base MD material of the connection element.
Surface Treatment • The valve body is painted with a two component paint • The solenoid and the cover are re zinc-nickel coated • The socket head screws are zinc coated
Manual Override • Integrated (–) Actuation pin integrated in the armature tube. Actuation
by pressing the pin• Push-button (HF1) Integrated in the knurled nut. Actuation by pressing
the push-button• Spindle (HS1) Integrated in the knurled nut. Actuation by turning the
spindle (continuously variable valve actuation) Attention! The actuation of the manual override is possible up to a tank
pressure of:
• 160 bar Integrated (–)• 160 bar Push-button (HF1)• 160 bar Spindle (HS1)
Dimensions
Hydraulic Connection
AccessoriesProportional amplifier Mating connector grey (A) Mating connector black (B) Technical explanations Filtration & hydraulic fluidsRelative duty factor
NPD2, NSD7, NMD2Item # E209.21101 Item # E209.21102 Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Position Article Description
10 NE37V1950- Solenoid Coil NE37V 19x50
50 S200.16152 S600.16152
O-ring ID 5.28 x 1.78 (NBR) O-ring ID 5.28 x 1.78 (FKM)
60 S210.16187 O-ring ID 18.72 x 2.62 (NBR)
70 C274.15100 Knurled nut
80 A703.25101 Push-button
90 A703.25100 Spindle
Parts List
39
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA6 NG6 Proportional Spool Valve Direct Operated
» ISO 4401-03» Manifold construction » Qmax = 1 1.096 gpm (42 l/min) » 4 volume flow levels » QN max = 8.454 gpm (32 l/min) » Pmax = 5076 psi (350 bar)
Technical DataDesignation: Proportional spool valve
Construction: Direct operated
Mounting: Manifold construction
Nominal size: NG6 according to ISO 4401-03
Actuation: Proportional solenoid
Ambient temperature: -13 to +158 °F (-25…+70 °C) NBR -4 to +158 °F (-20…+70 °C) FKM if » 122 °F (50 °C), IG is only conditionally achievable
Weight: 3.30 lb (1.5 kg) 1 solenoid 4.44 lb (2.0 kg) 2 solenoids
MTTFd: 150 years
Seal Material: NBR or FKM (Viton) as standard
Solenoid Type: Proportional Solenoid, wet pin push type, Class H, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, Class 18 / 16 / 13
Filtration: Required filtration grade ß 6…10 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13°….+158°F (-25…+70 °C) NBR -4….+158°F (-20…+70 °C) FKM
Max. Volume Flow: Qmax = 5.284 gpm (20 l/min), see characteristics
Operating Pressure: pmax = 5076 PSI (350 bar)
Tank Pressure: pT Max= 3625 psi (250 bar)
Max. Volume Flow: Qmax = 11.09 gpm (42 l/min), see characteristics
Nominal Volume: QN= , 1.32; 2.64; 4.22; 8.45 gpm (5; 10; 16; 32 l/min)
Leakage Oil: See characteristics
Hysteriisis: < 5% at optimal dither signal
Description Direct operated proportional spool valve with 4 connections in 5-chamber system. Precise spool fit, low leakage, long service lifetime. The volume flow adjustment takes place by a Norgren proportional solenoid. Proportional to the solenoid current, the spool stroke, the spool opening and the valve volume flow increase. For the control, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional spool valves are ideally suited for demanding tasks due to the high resolution, large volume flow and low hysteresis. For use in industrial and mobile hydraulics applications for the smooth control of hydraulic actuators. Some examples: rotor blades control of wind generators, forestry and earth moving machines, machine tools and paper production machines with simple position control, robotics and fan control.Miniature valves are used wher both, reduced dimensions and weight are important.
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 30.9 watts 31.8 watts
Limiting Current (50°C)(A) IG=1.715 A IG=0.88 A
Limiting Power 20.6 watts 21.2 watts
Nominal Resitance 4.66 ohms 18.1 ohms
Number of Windings 620 1,250
Weight of Solenoid 0.72 lb (0.33 kg)
See solenoid NE45W datasheet in solenoid section of catalog
Solenoid Coil Connection:
Connector Type Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
40
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA6 NG6 Proportional Spool Valve Direct Operated
Symbols*
P T
BA
aa
bb0
ACBS
P T
BA
aa
b
AC1S
P T
BA
a bb
CB2S
Meter-in control
Symmetrical control
ADBV AD1V
P T
BA
a bb
DB2V
P T
BA
baa b
P T
BA
aa
b
Configurator NW D P FA6 32 - W1NSSpool Valve NW
Directly Operated D
Proportional P
Manifold Construction F
Mounting Interface Acc. to NG3-mini A6
Symbol Code*
Nominal Volume flow rate QN
32 l/min 32
Nominal Voltage UN 12 VDC 12
24 VDC 24
Without Coil* X5
Slip-on Coil (Skip if X5)
W Metal housing round
Connection (Skip if X5)
D Connector socket EN 175301-803 / ISO 440
G Connector deutsch DT04-2P
Sealing Material
1 NBR
Manual Overide
N Integrated
Surface Protection
S Standard
P T
BA
aa
bb0
ACBS
P T
BA
aa
b
AC1S
P T
BA
a bb
CB2S
Meter-in control
Symmetrical control
ADBV AD1V
P T
BA
a bb
DB2V
P T
BA
baa b
P T
BA
aa
b
* For ordering information please see Solenoid Coils section of this catalog, NE45W
Note: Use symbol codes above for part number configurator.
41
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA6 NG6 Proportional Spool Valve Direct Operated
Q = f (p) Volume flow pressure characteristicsI = IG
ACB-S, AC1-S, CB2-S
50
40
30
20
10
00 50 100 150 200 250 300 350 p [bar]
K1115
Q [l/min]
QN = 32 l/min
QN = 16 l/min
QN = 10 l/minQN = 5 l/min
Q = f (p) Volume flow pressure characteristicsI = IG
ADB-V
50
40
30
20
10
00 50 100 150 200 250 300 350 p [bar]
K1116
Q [l/min]
QN = 32 l/minQN = 16 l/min
QN = 10 l/minQN = 5 l/min
∆p = f (Q) Pressure drop volume flow characteristicsI = IG
ACB-S, AC1-S, CB2-S
353025201510
50
0 4 8 12 16 20 24 28 32 Q [l/min]
K1111
p [bar]QN = 5 l/min QN = 10 l/min QN = 16 l/min
QN = 32 l/min
∆p = f (Q) Pressure drop volume flow characteristicsI = IG
ADB-V
353025201510
50
0 4 8 12 16 20 24 28 32 Q [l/min]
K1111
p [bar]QN = 5 l/min QN = 10 l/min QN = 16 l/min
QN = 32 l/min
Q = f (I) Volume flow adjustment characteristics∆p = 10 barACB-S, AC1-S, CB2-S
K1113
Q [l/min]
-100 -80 -60 -40 -20 0 20 40 60 80 100
3025201510
50
QN = 32 l/min
QN = 16 l/min
QN = 10 l/min
QN = 5 l/min
l [%]
Q = f (I) Volume flow adjustment characteristics∆p = 10 barADB-V
K1114
Q [l/min]
-100 -80 -60 -40 -20 0 20 40 60 80 100
3025201510
50
QN = 32 l/min
QN = 16 l/min
QN = 10 l/min
QN = 5 l/min
l [%]
Performance SpecificationsOil viscosity u = 30 mm2/s
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
42
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPFA6 NG6 Proportional Spool Valve Direct Operated
210
10
37
51 HF1
80 37
57 HS1
90
A B
W =
45
68 13
49
152
21 50
83
9.5
5.2
8
41
M D=
M D=
70 60 10 50
5Nm
5.2Nm
152
M =
45
18 53
86
10
A
A
Installation Notes Manifold mounting Mounting type 4 Mounting holes for socket head screws M5 x 50
Mounting position Any, preferably horizontal
Tightening torque MD= 5.2 Nm (quality 8.8) mounting screws MD = 5 Nm knurled nut
Note: The length of the mounting screw depends on the base MD material of the connection element.
Surface Treatment Standard:
- The valve body is painted with a two component paint - The armature tube, the slip-on coil and the plug screw are zinc-nickel
coated
Optionally (K8): - All external parts are zinc-nickel coated ISO 9227 (800 h) salt spray test
Dimensions
Hydraulic Connection 17.8
21
32.
5
31
40.5
21.5
B
T
P
A
Manual Override • Integrated (–) Actuation pin integrated in the armature tube. Actuation
by pressing the pin• Push-button (HF1) Integrated in the knurled nut. Actuation by pressing
the push-button• Spindle (HS1) Integrated in the knurled nut. Actuation by turning the
spindle (continuously variable valve actuation) Attention! The actuation of the manual override is possible up to a tank
pressure of: • 160 bar Integrated (–)• 160 bar Push-button (HF1)• 160 bar Spindle (HS1)
AccessoriesProportional amplifier Mating connector grey (A) Mating connector black (B) Mounting screwsTechnical explanations Filtration & hydraulic fluidsRelative duty factor
NPD2, NSD7, NMD2Item # E209.21101 Item # E209.21102 Data sheet 5.400.046Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Position Article Description
10 NE45W2350- Solenoid Coil NE45W 23x50
50S200.16193 S600.16192
O-ring ID 9.25 x 1.78 (NBR) O-ring ID 9.25 x 1.78 (FKM)
60 S220.16122 O-ring ID 22.22 x 2.62 (NBR)
70 C274.15101 Knurled nut M23 x 1.5 x 19.7
80 A703.25104 Push-button
90 A703.25102 Spindle
Parts List
43
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPF65A10 NG10 Proportional Spool Valve Direct Operated
» Manifold construction » Direct operated, pressure compensated » Qmax = 26 gpm (100 l/min), pmax = 5076 psi (350 bar) » QN max = 17 gpm (65 l/min)
Technical DataDesignation: 4/3 proportional directional contrLool valve
Construction: Direct operated
Operation: Proportional solenoid
Mounting: Manifold construction
Mounting Position: Any, preferably horizontal
Mounting Type: Manifold mounting 4 fixing holes for socket head screws M6 x 40
Mounting interface Standard: ISO 4401-05
Weight: 8.6 lb (3.9 kg) 1 solenoid 11.9 lb (5.4 kg) 2 solenoids
Fastening Torque: Fixing screw MD = 10.5 Nm ± 10 % (screw quality 8.8, zinc coated) MD = 13.5 Nm ± 10 % (screw quality 10.9, zinc coated) Knurled nut MD = 5 Nm The length of the fixing screw depends on the base material of the connection element.
Nominal size: NG10 according to ISO 4401-05
Ambient Temperature: -13...+150 °F (-25…+70 °C), if »122 °F (50 °C) IG is only conditionally achievable
Seal Material: NBR or FKM (Viton) as standard
Solenoid Type: Switching solenoid, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Viscosity Range: 12 mm2/s…320 mm2/s
Contamination Efficiency: ISO 4406:1999, class 18/16/13
Filtration: Required filtration grade ß 6 to 10 ≥ 75, see data sheet 5.400.044
Fluid Temperature: -13 to +150 °F (-25 to +70 °C) NBR -4 to +150 °F (-20 to +70 °C) FKM
Flow Direction: See Symbols
Peak Pressure: pmax = 5076 psi (350 bar)
Tank Pressure: pT max = 2300 psi (160bar)
Nominal Volume: QN max = 17 gpm (65 l/min)
Max. Volume Flow: Qmax = 26 gpm (100 l/min), see characteristics
Leakage Oil: See characteristics
Hysteresis: ≤ 7 % at optimal dither signal
Description Direct operated proportional spool valve in screw-in cartridge construction. Precise spool fit, low leakage, long service lifetime. The volume flow adjustment takes place by a Norgren proportional solenoid. The valve works according to the pull-push principle. With the control of the solenoids, the volume flow direction P to A or P to B can be selected. Thanks to the optimum spool form, sensitive movement processes are possible. For the control, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional spool valves are ideally suited for demanding tasks due to the high resolution, large volume flow and low hysteresis. For use in industrial and mobile hydraulics applications for the smooth control of hydraulic actuators. Some examples: control of the rotor blades of wind generators, forestry and earth moving machines, machine tools and paper production machines, simple position controls, robotics and fan control.
See solenoid NE64W datasheet in solenoid section of catalog
Standard Nominal Voltage
Limiting Current
Nominal Power
Limiting Power
Nominal Resistance
Weight of Solenoid
U = 12 VDC U = 24 VDC
IG = 2,225 mA IG = 1105 mA
39 watts 38 watts
27.1 watts 26.5 watts
3.7 ohms 15.2 ohms
2.22 lb (1.0 kg)
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
Solenoid Coil Electrical Specifications:
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
44
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPF65A10 NG10 Proportional Spool Valve Direct Operated
Symbols*Symmetrical control
P T
BA
aa
bb0
ACB-S
P T
BA
aa
b
AC1-S
P T
BA
a bb
CB2-S
Meter-in controlADB-V AD1-V
P T
BA
a bb
DB2-V
P T
BA
baa b
P T
BA
aa
b
NW D P F 65 A10 - - 1 NSpool Valve NW
Direct Operated D
Proportional P
Manifold Construction F
Nominal Volume Flow Rate QN 90 l/min 65
International Standard Interface ISO, NG10 A10
Symbol Code*
Nominal Voltage UN 12 VDC 12
24 VDC 24
Without Coil* X5
Slip-on Coil Metal housing round (Skip if X5) W
ConnectionExecution (Skip if X5)
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Sealing Material NBR 1
Manual Override Integrated N
Configurator
* For ordering information please see Solenoid Coils section of this catalog, NE64W
Note: Use symbol codes above for part number configurator.
45
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Q = f (p) Volume flow pressure characteristicsI = IG
ACB-S, AC1-S, CB2-S
100
80
60
40
20
00 50 100 150 200 250 300 350 p [bar]
K2086
Q [l/min]
Q = f (p) Volume flow pressure characteristicsI = IG
ADB-V, AD1-V, DB2-V
100
80
60
40
20
00 50 100 150 200 250 300 350 p [bar]
K2087
Q [l/min]
∆p = f (Q) Pressure drop volume flow characteristicsI = IG
ACB-S, AC1-S, CB2-S
141210
86420
0 10 20 30 40 50 60 70 Q [l/min]
K2088
p [bar]
∆p = f (Q) Pressure drop volume flow characteristicsI = IG
ADB-V, AD1-V, DB2-V
141210
86420
0 10 20 30 40 50 60 70 Q [l/min]
K2089
p [bar]
Q = f (I) Volume flow adjustment characteristics∆p = 10 barACB-S, AC1-S, CB2-S
-100 -80 -60 -40 -20 0 20 40 60 80 100 I [%]
K2090
Q [l/min]70605040302010
0
Q = f (I) Volume flow adjustment characteristics∆p = 10 barADB-V, AD1-V, DB2-V
-100 -80 -60 -40 -20 0 20 40 60 80 100 I [%]
K2091
Q [l/min]70605040302010
0
QL = f (p) Leakage volume flow characteristics per control edge
400350300250200150100
500
0 50 100 150 200 250 300 350 p [bar]
K2092
Q [ml]
NWDPF65A10 NG10 Proportional Spool Valve Direct Operated
Characteristics Oil viscosity v = 30 mm2/s
Note: All values were measured over two control edges. The connections A and B were short-circuited.
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
46
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPF65A10 NG10 Proportional Spool Valve Direct Operated
Surface Treatment - The valve body is painted with a two component paint - The armature tube, the slip-on coil and the plug screw are zinc-nickel coated
307
BA
51
71
90
HS1
51
65
80
HF1
29
93 14
214
6.5
10.5
69.
5
72 35
W =
64
10
4
A
MD=
MD=
70 60 10 50
5Nm
5.2Nm
214 M
=60
35 72 1
05
A
10
Dimensions
Hydraulic Connection
46
54
1.5
16.
8
9.7
20.8
24
A B
P
T To
Manual Override • Integrated (–) Actuation pin integrated in the armature tube.
Actuation by pressing the pin.• Push-button (HF1) Integrated in the knurled nut. Actuation by pressing the push-button.• Spindle (HS1) Integrated in the knurled nut. Actuation by turning the spindle (continuously variable valve actuation)
Attention! The actuation of the manual override is possible up to a tank pressure of:• 20 bar Integrated (–)• 20 bar Push-button (HF1)• 80 bar Spindle (HS1)
AccessoriesProportional amplifier Mating connector grey (A) Mating connector black (B) Mounting screwsTechnical explanations Filtration & hydraulic fluidsRelative duty factor
NPD2, NSD7, NMD2Item # E209.21101 Item # E209.21102 Data sheet 5.400.046Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Installation Notes Mounting type
Mounting position
Manifold mounting 4 mounting holes for socket head screws M6 x 40
Any, preferably horizontal MD = 13.5 Nm ± 10 %, quality min. 10.9 MD = 10.5 Nm ± 10 %, quality 8.8: Maximum tank pressure without external connections: 1160 psi (80 bar) Maximum tank pressure and maximum pressure external connections: 507.5 psi (35 bar)
Note: The length of the fixing screw depends on the base material of the connection element.
Position Article Description
10 NE64W3172- Solenoid Coil NE64W 31x72
50 S210.16120 S810.16124
O-ring ID 12.42 x 1.78 (NBR) O-ring ID 12.42 x 1.78 (FKM)
60 S220.16182 O-ring ID 28.24 x 2.62 (NBR)
70 C274.15106 Knurled nut
80 A703.25106 Push-button
90 A703.25105 Spindle
Parts List
47
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NVPF90A10 NG10 Proportional Spool Valve Pilot Operated
Factory Automation
» Manifold construction » Pilot operated » Qmax =52.8 gpm (200 l/min) » QN max = 23.78 gpm (90 l/min) » pmax = 5076 psi (350 bar)
Technical DataDesignation: 4/3 proportional directional control valve
Construction: Pilot operated
Operation: Proportional solenoid
Mounting: Manifold construction
Mounting Position: Any, preferably horizontal
Mounting Type: Manifold mounting 4 fixing holes for socket head screws M6 x 40
Mounting interface Standard: ISO 4401-05
Weight: 7.71 lb (3.5 kg) 1 solenoid 8.60 lb (3.9 kg) 2 solenoids
Fastening Torque: MD = 13.5 Nm ± 10 %, quality min. 10.9 MD = 10.5 Nm ± 10 %, quality 8.8
Nominal size: NG10 according to ISO 4401-05
Ambient Temperature: -13…158 °F (25…+70 °C) NBR -4…158 °F (-20…+70 °C) FKM if » 122 °F (50 °C), IG is only conditionally achievable
Seal Material: NBR or FKM (Viton) as standard
Fluid: Mineral oil, other fluid on request
Viscosity Range: 12 mm2/s…320 mm2/s
Contamination Efficiency: ISO 4406:1999, class 18/16/13
Filtration: Required filtration grade ß 6 to 10 ≥ 75, see data sheet 5.400.044
Fluid Temperature: -4…158°F (-20…+70 °C)
Flow Direction: See Symbols
Pilot Pressure: pv = 362.5…5076 psi (25...350 bar)
Connection X: pv = 362.5…2900 psi (25...200 bar)
Peak Pressure: pmax = 5076 psi (350 bar)
Tank Pressure: pT max = 2320 psi (160 bar), type of pilot operation ae and xi pT max = 1450 psi (100 bar), type of pilot operation ti and xe
Nominal Volume: QN max = 23.78 gpm (90 l/min)
Max. Volume Flow: Qmax = 52.8 gpm (200 l/min), see characteristics
Description Pilot operated proportional spool valve with 4 connections in 5-chamber system. Precise spool fit, low leakage, long service lifetime. Very compact construction with corresponding low weight. The pilot valve is a proportional solenoid operated pressure reducing valve. The function of the pilot and main valve as well as the interaction of both valves can be found in the hydraulic diagram. Proportional to the solenoid current, the spool stroke, the spool opening and the valve volume flow increase. The proportional spool valve is not pressure compensated. For the control, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional spool valves are ideally suited for demanding tasks due to the high resolution, large volume flow and low hysteresis. Pilot operated valves are used where large volume flows have to be controlled. Due to the large flow range and the high stiffness of the actuation, as a result of the pilot control, these valves are used for applications where fast acceleration and deceleration processes, high speeds and sensitive motion sequences are required. For use in industrial and mobile hydraulics applications for the smooth control of hydraulic actuators.
Pressure pilot oil drain: Minimum 362 psi (25 bar) lower than pv
Leakage Oil: See characteristics
Hysteresis: ≤ 7 % at optimal dither signalSolenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
See solenoid NS37W datasheet in solenoid section of catalog
Standard Nominal Voltage
Limiting Current
Nominal Power
Limiting Power
Nominal Resistance
Weight of Solenoid
U = 12 VDC U = 24 VDC
IG =1.36 A IG = 0.68 A
27.1 watts
26.5 watts
5.5 ohms 22.7 ohms
0.5 lb (0.23 kg)
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
48
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NVPF90A10 NG10 Proportional Spool Valve Pilot Operated
Symbols*Symmetrical control
P T
BA
ba 0a ab b
P T
BA
a b
P T
BA
BCA-S BC1-S CA2-S
Meter-in control
P T
BA
ba0
a a bb
P T
BA
a b
P T
BA
BDA-V BD1-V DA2-V
Types of pilot operation
P TYX P TYX P TYX P TYX
B
B
A BA BA BA
A
a
ti xi xe ae
b
BA
a b
BA
a b
BA
a b
NW V P F 90 A10 - - 1Spool Valve NW
Pilot Operated V
Proportional P
Manifold Construction F
Nominal Volume Flow Rate QN 90 l/min 90
International Standard Interface ISO, NG10 A10
Symbol Code*
Type of pilot operation: Control oil supply (x) and drain (y)
(x) and (y) internally ti
Nominal Voltage UN 12 VDC 12
24 VDC 24
Without Coil* X5
Slip-on Coil (Skip if X5)
Metal housing round W
ConnectionExecution (Skip if X5)
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Sealing Material NBR 1
Configurator
* For ordering information please see Solenoid Coils section of this catalog, NS37W
Note: Use symbol codes for part number configurator.
49
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves Ma
nifod
l Mo
unt
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NVPF90A10 NG10 Proportional Spool Valve Pilot Operated
Performance SpecificationsOil viscosity u = 30 mm2/s
∆p = f (Q) Pressure drop / flow characteristic over 2 control edges[Types: BCA-S, BC1-S, CA2-S, BDA-V, BD1-V, DA2-V]
K4249
∆p [bar]
Q [l/min]160 180140100 12060 800 20 40 200
40
30
20
10
0
Q = f (I) Volume flow signal characteristics over 2 control edges[Types: BCA-S, BC1-S, CA2-S, BDA-V, BD1-V, DA2-V]
K4129
Q [l/min]
I [%]9070 8050 6020 30 40 100
200
160
120
80
40
0
10 bar
20 bar
30 bar
50 bar100,~200 bar
QL = f (p) Leakage volume flow characteristics main stageper control edge
400350300250200150100
500
0 50 100 150 200 250 300 350 p [bar]
K2092
Q [ml]
QL = f (p) Leakage volume flow pilot control stage
@ 350 bar, p red 0 bar: 100 ml/min @ 350 bar, p red 25 bar: 320 ml/min
Note: All values were measured over two control edges. The connections A and B were short-circuited.
Pro
po
rtiona
l Directio
nal C
ontro
l Va
lves - Ma
nifod
l Mo
unt
50
2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NVPF90A10 NG10 Proportional Spool Valve Pilot Operated
Dimensions Hydraulic Connection
70.8
68
46
54
93
16.
8 1
.5
20.8
9.7
48
12
To
B
P
A
T
X Y
35
27 93
147
6.5
10.5
205
57.2
192.6 6.2
29
146
.8
20
10 40 30
60
68
38
69.
6
118
.3
BA
4/2-way spool valve (spring reset)
138.35
176
146
.8
A
4/3-way spool valve (spring centring)
Standards Mounting interface Solenoids Connection execution D Protection class Contamination efficiency
ISO 4401-05 DIN VDE 0580 EN 175301 – 803 EN 60 529 ISO 4406
Surface Treatment - The main valve body, the screw plugs, the slip-on coil
and the armature tube are zinc-nickel coated- The pilot valve body is coated with a two component
paint
ActuationPressure reducing valve (included)- NMDPFA04-P / AB-25 for BCA-S / BDA-V- NMDPFA04-P / B-25 for BC1-S / BD1-V- NMDPFA04-P / A-25 for CA2-S / DA2-V- Connector socket EN 175301 – 803
AccessoriesMounting ScrewsTechnical explanations Filtration & hydraulic fluidsRelative duty factor
Data sheet 5.400.046Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Installation Notes
Mounting type
Mounting position
Manifold mounting 4 mounting holes for socket head screws M6 x 40
Any, preferably horizontal MD = 13.5 Nm ± 10 %, quality min. 10.9 MD = 10.5 Nm ± 10 %, quality 8.8: Maximum tank pressure without external connections: 1160 psi (80 bar) Maximum tank pressure and maximum pressure external connections: 507.5 psi (35 bar)
Note: The length of the fixing screw depends on the base material of the connection element.
Position Article Description
10 A729.23103 Screw Plug
20 A216.24146 Socket head screw M5 x 45 DIN 912
30 S210.16120S810.16124
O-ring ID 12.42 x 1.78 (NBR) O-ring ID 12.42 x 1.78 (FKM)
40 S200.16176 S800.16176
O-ring ID 7.65 x 1.78 (NBR) O-ring ID 7.65 x 1.78 (FKM)
60 S200.16152 S600.16152
O-ring ID 5.28 x 1.78 (NBR) O-ring ID 5.28 x 1.78 (FKM)
NS37W1950- Solenoid Coil NS37W 19x50
Parts List
Features
• Compact 4/3 functionality
• Direct and pilot operated options
• Linear flow control characteristics
• Low leakage oil characteristics
• 4.7 gpm ( l/min) to 39 gpm (150 l/min) flow rates at 5000 psi (350 bar)
• 12 and 24v DC control
Norgren’s proportional directional control cartridge valves feature 4/3 funtionality and high flow rates in a compact package, with robust and precise construction for low leakage, hysteresis and reliable operation. For use in speed control in industrial and mobile applications where footprint is a consideration.
Proportional Directional Control - Cartridge Valves
52
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPU10 Proportional Spool Cartridge Valve Direct Operated
» Screw-in cartridge » Direct Operated » Qmax = 7.4 gpm (28 l/min) » QNmax =4.76 gpm (18 l/min) » pmax = 5076 psi (350 bar)
Technical DataDesignation: Proportional spool valve
Construction: Direct operated
Operation: Proportional solenoid
Mounting: Screw-in cartridge type
Mounting Position: Any, preferably horizontal
Mounting Type: 7/8“-14 UNF
Mounting interface Standard: ISO 4401-05
Weight: 1.52 lb (0.69 kg) 1 solenoid 1.74 lb (0.79 kg) 2 solenoids
Nominal size: 7/8“-14 UNF
Fastening Torque: Mounting screw MD = 10.5 Nm ± 10 % (screw quality 8.8, zinc coated) Max. tank pressure 1160 psi (80 bar) MD =13.5 Nm ± 10 % (screw quality 10.9, zinc coated) Knurled nut MD = 5 Nm The length of the fixing screw depends on the base material of the connection element.
Relative Duty Factor: 100 % ED / DF
Ambient Temperature: -13...+150 °F if »122 °F (-25…+70 °C if »50 °C), IG is only conditionally achievable
Solenoid Type: Switching solenoid, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Seal Material: NBR or FKM (Viton) as standard
Fluid: Mineral oil, other fluid on request
Viscosity Range: 12 mm2/s…320 mm2/s
Contamination Efficiency: ISO 4406:1999, class 18/16/13
Filtration: Required filtration grade ß 6 to 10 ≥ 75, see data sheet 5.400.044
Fluid Temperature: -13 to +150 °F (-25 to +70 °C) NBR -4 to +150 °F (-20 to +70 °C) FKM
Flow Direction: See Symbols
Working Pressure: pmax = 5076 psi (350 bar)
Tank Pressure: pT max = 3625 psi (250 bar)
Max. Volume Flow: Qmax = 7.936 gpm (28 l/min), see characteristics Leakage Oil: See characteristics
Hysteresis: ≤ 7 % at optimal dither signal
Description Direct operated proportional spool valve in screw-in cartridge construction. Precise spool fit, low leakage, long service lifetime. The volume flow adjustment takes place by a Norgren proportional solenoid. The valve works according to the pull-push principle. With the control of the solenoids, the volume flow direction P to A or P to B can be selected. Thanks to the optimum spool form, sensitive movement processes are possible. For the control, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional spool valves are ideally suited for demanding tasks due to the high resolution, large volume flow and low hysteresis. For use in industrial and mobile hydraulics applications for the smooth control of hydraulic actuators. Some examples: control of the rotor blades of wind generators, forestry and earth moving machines, machine tools and paper production machines, simple position controls, robotics and fan control.
Solenoid Coil Electrical Specifications:
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 20.5 watts
Limiting Current (50°C) 1.16 A 0.58 A
Limiting Power 14 watts
Nominal Resitance 7 ohms 28 ohms
Number of Windings 710 1420
Weight of Solenoid 0.48 lb (0.22 kg)
See solenoid NE37W datasheet in solenoid section of catalog
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
53
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPU10 Proportional Spool Cartridge Valve Direct Operated
Configurator NW D P U10 - 18 - W 1 X
Symbols*Symmetrical control
3 1
42
ab 0
ACB-S Meter-in control
3 1
42
b a
ADB-V
Spool Valve NW
Directly Operated D
Proportional P
Screw-in Cartridge, 7/8 14 UNF U10
Symbol Code*
Nominal Volume Flow Rate QN 18 l/min 18
Nominal Voltage UN
12 VDC 12
24 VDC 24without coil* X5
Slip-on Coil (skip if X5)
Metal housing round W
ConnectionExecution (Skip if X5)
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Sealing Material NBR 1
Manual Override Without X
With W
* For ordering information please see Solenoid Coils section of this catalog, NE37W
Note: Use symbol codes above for part number configurator.
54
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPU10 Proportional Spool Cartridge Valve Direct Operated
Performance SpecificationsOil viscosity u = 30 mm2/s
Q = f (p) Volume flow pressure characteristicsI = IG
ACB-S
0 50 100 150 200 250 300 350 p [bar]
K4117
Q [l/min]3025201510
50
P - BA - T
P - AB - T
Q = f (p) Volume flow pressure characteristicsI = IG
ADB-V
K4121
Q [l/min]3025201510
50
p [bar]0 50 100 150 200 250 300 350
P - BA - T
P - AB - T
∆p = f (Q Pressure drop volume flow characteristicsI = IG
20
15
10
5
00 5 10 15 20 25 Q [l/min]
K4116_1
p [bar]
Q = f (I) Volume flow adjustment characteristics∆p = 10 barACB-S
-100 -80 -60 -40 -20 0 20 40 60 80 100 I [%]
K4115
Q [l/min]20
16
12
8
4
0
P - BA - T
P - AB - T
Q = f (I) Volume flow adjustment characteristics∆p = 10 barADB-V
-100 -80 -60 -40 -20 0 20 40 60 80 100 I [%]
K4119
Q [l/min]20
16
12
8
4
0
P - BA - T
P - AB - T
QL = f (Q) Leakage volume flow characteristicsper control edgeACB-S
350300250200150100
500
p [bar]
K4114
Q [cm3/min]
0 50 100 150 200 250 300 350
QL = f (Q) Leakage volume flow characteristicsper control edgeADB-V
350300250200150100
500
p [bar]
K4118_1
Q [cm3/min]
0 50 100 150 200 250 300 350
Note: All values were measured over two control edges. The connections A and B were short-circuited.
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
55
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWDPU10 Proportional Spool Cartridge Valve Direct Operated
159.2
62 97.2
W =
37
77
M D= 5Nm
7/8"
-14U
NF-
2A
4(B) 3(P) 2(A)
1(T)
20 30 40 50 90 60 70 100 80 11010
s24
90°
Pull
PushLock
M =
35
74.
8
10
33.4
14
.5
HP
A
B B
A
Manual OverrideOptionally:HP
Surface Treatment - The valve body is painted with a two component paint - The armature tube, the slip-on coil and the plug screw are zinc-nickel coated
Dimensions
Hydraulic ConnectionCavity drawing according to Norgren Standard
For detailed cavity drawing and cavity tools see datasheet 5.400.034
Note: The actuation of the manual override is possible up to a tank pressure of approx. 100 bar. The manual override cannot be retrofitted.
AccessoriesProportional amplifier Mating connector grey (A) Mating connector black (B) Technical explanations Filtration & hydraulic fluidsRelative duty factor
NPD2, NSD7, NMD2Item # E209.21101 Item # E209.21102 Data sheet 5.400.045Data sheet 5.400.044Data sheet 5.400.043
Position Article Description
10 NE37W1640- Solenoid Coil NE37W 16x40
20 C267.15100 Knurled nut M16 x 1 x 9
30 S210.16156 O-ring ID 15.60 x 1.78 (NBR)
40 S110.16162 O-ring ID 16.00 x 1.25 (NBR)
50 S210.16188 S610.16188
O-ring ID 18.77 x 1.78 (NBR) O-ring ID 18.77 x 1.78 (FKM)
60 S210.16156 S610.16156
O-ring ID 15.60 x 1.78 (NBR) O-ring ID 15.60 x 1.78 (FKM)
70 S210.16140 S610.16141
O-ring ID 14.00 x 1.78 (NBR) O-ring ID 14.00 x 1.78 (FKM)
80 S210.16120 S610.16124
O-ring ID 12.42 x 1.78 (NBR) O-ring ID 12.42 x 1.78 (FKM)
90 S319.04196 Backup ring rd 16.1 x 19 x 1.4
100 S319.77104 Back-up ring rd 14.6 x 17.5 x 1.4
110 S319.04166 Backup ring rd 13.1 x 16 x 1.4
Parts List
56
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWVPM33 Proportional Spool Cartridge Valve Pilot Operated
» Pilot Operated » Qmax = 39.625 gpm (150 l/min) » pmax = 5076 psi (350 bar)
Technical DataDesignation: Proportional spool valve
Construction: Pilot operated
Operation: Pilot valve
Mounting: Screw-in cartridge type
Mounting Position: Any, preferably horizontal
Actuation: Proportional pressure reducing valve NMDPP16 (data sheet 5.400.030)
Minimum Pilot Pressure: 65.27 psi (4.5 bar)
Maximum Pilot Pressure: 435 psi (30 bar)
Fastening Torque: MD= 70…80 Nm Screw-in cartridge
Nominal Size: M33 x 2 according to Norgren standard
Weight: 1.74 lb (0.79 kg)
Ambient Temperature: -22 to +194 °F (-30…+90 °C)
MTTFd: 150 years
Seal Material: NBR as standard
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, class 18/16/13
Filtration: Required filtration grade ß 6 to 10 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -4 to +158 °F (-20 to +70 °C)
Flow Direction: See Symbols
Operating Pressure: pmax = 5076 psi (350 bar)
Nominal Volume: QN = 23.7 gpm (90 l/min)
Max. Volume Flow: Qmax = 39.6 gpm (150 l/min), see characteristics
Leakage Volume Flow: P→T at 2900 psi (200 bar): < 0.1057 gpm (0.4 l/min)
Description Pilot operated proportional spool valve in screw-in cartridge construction. Precise spool fit, low leakage, long service life time. Spool made of hardened steel. The valve is controlled externally through a pilot pressure via the x and y connections. Without control, the piston is held in the central positon by a spring. Proportional to thepilot pressure, the spool opening and the valve volume flow increase. Thanks to the optimum spool form, sensitive movement processes are possible. For the control, Norgren proportional pressure valves (NMDP16) and Norgren proportional amplifiers are available(see proportional amplifier section under accessories).
Application Proportional spool valves are ideally suited for demanding tasks due to the high resolution, large volume flow and low hysteresis. For use in industrial and mobile hydraulics applications for the smooth control of hydraulic actuators. Some examples: rotor blades control of wind generators, forestry and earth moving machines, machine tools and paper production machines with simple position control, robotics and fan control.
Configurator Spool Valve
Directly Operated
Proportional
Screw-in Cartridge M33 x 2
Symbol Code*
Nominal Volume flow rate QN
NW
V
P
M33
90
SymbolsSymmetrical control
P T
BA
x y
P T
BA
x y
ACB-S CB2-S
Meter-in controlADB-V DB2-V
P T
BA
x y
P T
BA
x y
NW V P M33 - 90
Note: Use symbol codes above for part number configurator.
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
57
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWVPM33 Proportional Spool Cartridge Valve Pilot Operated
Q = f (∆p) Volume flow pressure characteristics
160140120100
80604020
00 2 4 6 8 10 12 14 16 18 20 22 24 p [bar]
K1072
Q [l/min]A-T B-T
P-A, P-B
Q = f (pv) Volume flow pressure characteristics
20 16 12 8 4 0 4 8 12 16 20 pv [bar]
K1073
Q [l/min]100
80
60
40
20
0
P-A P-B
Performance CharacteristicsOil viscosity u = 30 mm2/s
Connection Example
A
x y
B
P T
MDPPM16 MDPPM16NMDPM16NMDPM16 NMDPM16NMDPM16
58
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWVPM33 Proportional Spool Cartridge Valve Pilot Operated
Surface Treatment - The valve body is painted with a two component paint - The armature tube, the slip-on coil and the plug screw are
zinc-nickel coated
s 30
Ø 40
6311
8.5
x
T
A
P
B
y
M33 x 2
30
MD = 70...80 Nm
Dimensions
Installation Notes Mounting type Mounting position Tightening torque
Screw-in cartridge M33 x 2 Any, preferably horizontal MD = 70...80 Nm Screw-in cartridge
Hydraulic ConnectionCavity drawing according to standard
M33x2
(1)
(2)
(4)
(x)
(y)
(3)
For detailed cavity drawing and cavity tools see datasheet 5.400.0050
AccessoriesProportional amplifier Proportional pressure valvesFiltration & hydraulic fluidsTechnical Explanations
NPD2, NSD7, NMD2NMDP16 5.400.030 Data Data sheet 5.400.044Data sheet 5.400.045
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
59
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWVPM42 Proportional Spool Cartridge Valve Pilot Operated
» Screw-in cartridge » Pilot Operated » Qmax = 66 gpm (250 l/min), pmax = 4,568 psi (315 bar) » 39.6 gpm (150 l/min) » M42 x 2
Technical DataDesignation: Proportional spool valve
Construction: Pilot operated
Operation: Proportional solenoid
Mounting: Screw-in cartridge type
Mounting Position: Any, preferably horizontal
Actuation: Proportional pressure reducing valve NMDPP16 (data sheet 5.400.030)
Minimum Pilot Pressure: 65.27 psi (4.5 bar)
Maximum Pilot Pressure: 435 psi (30 bar)
Fastening Torque: MD= 70…80 Nm Screw-in cartridge
Nominal Size: M42 x 2 according to Norgren standard
Weight: 3.08 lb (1.4 kg) Ambient Temperature: -22 to +194 °F (-30…+90 °C)
MTTFd: 150 years
Seal Material: NBR or FKM (Viton) as standard
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, class 18/16/13
Filtration: Required filtration grade ß 6 to 10 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -4 to +158 °F (-20 to +70 °C)
Flow Direction: See Symbols
Operating Pressure: pmax = 4568 psi (315 bar)
Nominal Volume: QN = 39.6 gpm (150 l/min)
Max. Volume Flow: Qmax = 66 gpm (250 l/min), see characteristics Leakage Volume Flow: P→T at 2,900 psi (200 bar): < 0.1321 gpm (0.5 l/min)
Description Pilot operated proportional spool valve in screw-in cartridge construction. Precise spool fit, low leakage, long service life time. Spool made of hardened steel. The valve is controlled externally through a pilot pressure via the x and y connections. Without control, the piston is held in the central positon by a spring. Proportional to the pilot pressure, the spool opening and the valve volume flow increase. Thanks to the optimum spool form, sensitive movement processes are possible. For the control, Norgren proportional pressure valves (NMDP16) and Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional spool valves are ideally suited for demanding tasks due to the high resolution, large volume flow and low hysteresis. For use in industrial and mobile hydraulics applications for the smooth control of hydraulic actuators. Some examples: rotor blades control of wind generators, forestry and earth moving machines, machine tools and paper production machines with simple position control, robotics and fan control.
SymbolsSymmetrical control
P T
BA
x y
P T
BA
x y
ACB-S CB2-S
Meter-in controlADB-V DB2-V
P T
BA
x y
P T
BA
x y
Configurator Spool Valve
Directly Operated
Proportional
Screw-in Cartridge M42 x 2
Symbol Code*
Nominal Volume flow rate QN
NW
V
P
M42
150
NW V P M42 - 150
Note: Use symbol codes above for part number configurator.
60
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWVPM42 Proportional Spool Cartridge Valve Pilot Operated
Q = f (∆p) Volume flow pressure characteristics
0 2 4 6 8 10 12 14 16 18 20 22 24 26 p [bar]
K1044
Q [l/min]350300250200150100
500
A-T
B-TP-A, P-B
Q = f (pv) Volume flow pressure characteristics
20 16 12 8 4 0 4 8 12 16 20 p [bar]
K1045
Q [l/min]160
120
80
40
0
P-A P-B
Performance CharacteristicsOil viscosity u = 30 mm2/s
Connection Example
A
x y
B
P T
MDPPM16 MDPPM16NMDPM16NMDPM16 NMDPM16NMDPM16
Pro
po
rtiona
l Directio
nal C
ontro
l - Ca
rtridg
e Va
lves
61
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NWVPM42 Proportional Spool Cartridge Valve Pilot Operated
M42x2
(1)
(2)
(4)
(x)
(y)
(3)
s 41
Ø 48
7013
9x
T
A
P
B
y
M42 x 2
41
MD = 80...100 Nm
Dimensions Hydraulic ConnectionCavity drawing according to standard
For detailed cavity drawing and cavity tools see datasheet 5.400.0051
Installation Notes Mounting type Mounting position Tightening torque
Screw-in cartridge M42 x 2 Any, preferably horizontal MD = 80...100 Nm Screw-in cartridge
Surface Treatment - The valve body is painted with a two component paint - The armature tube, the slip-on coil and the plug screw are zinc-
nickel coated
AccessoriesProportional amplifier Proportional pressure ValvesFiltration & hydraulic fluidsTechnical Explanations
NPD2, NSD7, NMD2NMDP16 5.400.030 Data sheet 5.400.044Data sheet 5.400.045
Features• Linear flow control characteristics
• Flows up to 21 gpm (80 l/min)
• Low hysteresis ≤ 7%
• Pressure max. 350 bar (5000 psi)
• 12 and 24v DC control
Norgren’s direct operated 2-way normally closed and 3-way proportional flow control cartridge valves are rated for pressures up to 5000 psi (350 bar) and flows up to 21 gpm (80 l/min). These valves are ideal for speed regulation applications of actuators and hydraulic motors with precise and repeatable performance.
Proportional Flow Control Valves
63
Pro
po
rtiona
l Flow
Co
ntrol V
alves
4
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NQPU16N Proportional 2-way Flow Control Cartridge Direct Operated - Load Compensated
» Screw-in cartridge » Direct operated, load compensated » Qmax = 21.8 gpm (80 l/min)» pmax = 5076 psi (350 bar) » 1 5/16”— 12 UN
Technical DataDesignation: Proportional 2-way flow control valve
Construction: Direct Operated
Operation: Proportional solenoid
Mounting: Screw-in cartridge for cavity
Mounting Position: Any, preferable horizontal
Fastening Torque: MD = 80 Nm Screw-in cartridge MD = 5 Nm knurled nut MD = 9.5 Nm HB0 MD = 5.5 Nm HB4.5
Nominal Size: Screw-in thread 1-5/16″-12 UN
Weight:2.09 lb (0.95 kg)
Ambient Temperature: -13 to +122 °F (-25 to +50 °C)
Seal Material: NBR or FKM (Viton) as standard
Solenoid Type: Proportional, wet pin push type, pressure tight, Class H
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, class 18/16/13
Filtration: Required filtration grade ß 6 to 10 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13 to +150 °F (-25 to +70 °C) NBR -4 to +150 °F (-20 to +70 °C) FKM
Flow Direction: See Symbols
Operating Pressure: pmax = 5076 psi (350 bar)
Nominal Volume: QN =32; 63; 80 l/min(8.45; 16.64; 21 gpm)
Volume Flow Hysteresis: Qmax = 8.45; 21; 16.64 gpm (32; 63; 80 l/min) [1 → 2] Qmin = 0.10 gpm (0.4 l/min)
Volume Flow Direction: See symbols
Hysteresis: ≤ 5 % at optimal dither signal
Description Direct operated, load compensated proportional flow control valve screw-in cartridge for UNF cavity. When the solenoid is de-energized, the control spool closes practically leakage-free. The change of the electric current is followed by a proportional volume flow change. From the input (1), the fluid flows over the control and throttling spool to the controlled output (2). For the control, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional flow control valves are suitable for precise speed control, where the load current has to be maintained constant independent of the input and output pressure.
SymbolDetailed QN
2
1
2
1
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
See solenoid NS45W datasheet in solenoid section of catalog
Standard Nominal Voltage
Limiting Current
Nominal Power
Limiting Power
Nominal Resistance
Weight of Solenoid
U = 12 VDC U = 24 VDC
IG =1560 mA IG = 780 mA
28 watts
18 watts
5.3 ohms 20.6 ohms
0.79 lb (0.36 kg)
Solenoid Coil Electrical Specifications:
Pro
po
rtiona
l Flow
Co
ntrol V
alves
64
4
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NQPU16N Proportional 2-way Flow Control Cartridge Direct Operated - Load Compensated
Configurator
Performance SpecificationsOil viscosity u = 30 mm2/s
Q = f (I) Volume flow signal characteristics
0 10 20 30 40 50 60 70 80 90 100
K0978
Q [l/min]100
80
60
40
20
0
QN = 80 l/minQN = 63 l/min
QN = 32 l/min
I [%]
Q = f (p) Volume flow pressure characteristics
100
80
60
40
20
00 50 100 150 200 250 300 350 p [bar]
K0979
Q [l/min]
QN = 80 l/min
QN = 63 l/min
QN = 32 l/min
QL = f (p) Leakage volume flow characteristics
400
300
200
100
00 50 100 150 200 250 300 350 p [bar]
K0980
Q [cm 3/min]
NQ P U16 N - W1 MFlow Control Valve NQ
Proportional P
Screw-in Cartridge 1 5/16“— 12 UN U16
Normally Closed N
Nominal Volume Flow Rate QN
63 l/min 63
80 l/min 80
Nominal Voltage UN
12 VDC 12
24 VDC 24
Without Coil* X5
Slip-on Coil (Skip if X5)
Metal housing round W
ConnectionExecution (Skip if X5)
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Sealing Material NBR 1
Manual Override M
Configurator
* For ordering information please see Solenoid Coils section of this catalog, NS45W
65
Pro
po
rtiona
l Flow
Co
ntrol V
alves
4
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NQPU16N Proportional 2-way Flow Control Cartridge Direct Operated - Load Compensated
W =
45.3
95.1 47
145.1
85
MD=5.5Nm
MD=5Nm
15
12 17 10 18 50 60701-
5/16
"-12
UN
-2A
s36
(2)
(1)
M =
45
84.
8
10
MD= 9.5Nm15
HB0
1-5/16"-12 UN-2B
(2)
(1)
W =
45.3
95.1 47
145.1
85
MD=5.5Nm
MD=5Nm
15
12 17 10 18 50 6070
1-5/
16"-
12U
N-2
A
s36
(2)
(1)
M =
45
84.
8
10
MD= 9.5Nm15
HB0
1-5/16"-12 UN-2B
(2)
(1)
Installation Notes Mounting type Screw-in cartridge type M16 x 1.5
Mounting position Any, preferably horizontal
Tightening torque MD= 30 Nm Screw-in cartridge MD = 5 Nm knurled nut MD = 9.5 Nm HB0 MD = 5.5 Nm HB4.5
Surface Treatment • The cartridge body is gas-nitro carburised• The slip-on coil and the armature tube are zinc-/nickel-coated
Sealing Material NBR or FKM (Viton) as standard, choice in the type code
Manual Override HB4.5Optional: Screw plug (HB0), no actuation possible
AccessoriesProportional amplifier Connector EN 175301-803Technical explanations Filtration & hydraulic fluids
NPD2, NSD7, NMD2Article no. E209.21102Data sheet 5.400.045 Data sheet 5.400.044
Dimensions
For detailed cavity drawing and cavity tools see datasheet 5.400.052
Hydraulic ConnectionCavity drawing according to standard
Position Article Description
10 NS45W2350- Solenoid Coil NS45W 23x50
12 C274.15101 Knurled nut M23 x 1.5 x 19.7
15 A803.25100 A209.23133
HB4.5 manual override HB0 Screw plug
17 S220.16122 O-ring ID 22.22x 2.62 (NBR)
18 S220.16122 O-ring ID 21.95 x 1.78 (NBR)
50 S220.16198 S620.16196
O-ring ID 29.82 x 2.62 (NBR)O-ring ID 29.82 x 2.62 (FMK)
60 S220.16138S620.16138
O-ring ID 23.81 x 2.62 (NBR) O-ring ID 23.81 x 2.62 (FMK)
70 S329.04197 Backup ring rd 24.5 x 29 x 1.4
Parts List
Pro
po
rtiona
l Flow
Co
ntrol V
alves
66
4
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
» Screw-in cartridge » Direct operated, load compensated » Qmax = 26 gpm (100 l/min)» pmax = 5076 psi (350 bar) » 1 5/16”— 12 UN
Technical DataDesignation: 3-way proportional flow control valve
Construction: Direct operated
Operation: Proportional solenoid
Nominal Size: Screw-in thread 15/16″-12 UN
Mounting: Screw-in cartridge for cavity
Mounting Position: Any, preferably horizontal
Weight:2.2 lb (1.0 kg)
Fastening Torque: MD = 80 Nm for screw-in cartridge MD = 7 Nm for knurled nut
Ambient Temperature: -13 to +122 °F (-25 to +50 °C)
Seal Material: NBR or FKM (Viton) as standard
Solenoid Type: Proportional, wet pin push type, pressure tight, Class H
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF (data sheet 1.1- 430)
Fluid: Mineral oil, other fluid on request
Solenoid Connection Execution:WD45/23x50 (see data sheet)WJ45/23x50 (see data sheet)WG45/23x50 (see data sheet)
Contamination Efficiency: ISO 4406:1999, class 18/16/13
Filtration: Required filtration grade ß 6 to 10 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13 to +150 °F (-25 to +70 °C) NBR -4 to +150 °F (-20 to +70 °C) FKM
Flow Direction: See Symbols
Working Pressure: pmax = 5076 psi (350 bar)
Nominal Volume: QN =32; 63; 80 l/min
Volume Flow Hysteresis: Qmax = 26 gpm (100 l/min) [1 → 2] Qmin = 0.11 gpm (0.4 l/min)
Volume Flow Direction: See symbols
Hysteresis: ≤ 5 % at optimal dither signal
Description Direct operated, pressure compensated proportional flow control valve as a screw-in cartridge with a thread 15/16″-12 UN for cavity acc. Two flow ranges areavailable. The volume flow is adjusted by a Norgren proportional solenoid (VDE standard 0580). The cartridge body is made of steel. A special surface treatment guarantees a good protection against corrosion and wear as well as very good low-friction characteristics of the pressure compensating- and throttle spool. The solenoid coil is zinc- /nickel-coated.
Function The 3-way flow control valve serves for maintaning the speed of a consumer constant independent of the load. Superfluous pump output flow is fed into the return flow system in a cost saving manner, and as a result, prevents an overheating of the hydraulic system. The power controlled, proportional solenoid running in oil acts directly on the throttle spool, which opens the throttle segments in the cartridge body. Proportional to the current demand of the proportional solenoid, the throttle aperture changes, and with this the volume flow. In case of a current-free solenoid, the throttle spool is held in closed position by a spring. For driving the valve, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application Proportional flow control valves are suitable for feed control systems, where the consumer flow has to be maintained constant with a changing load. The screw-in cartridge is suitable for installation in control blocs.
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k
See solenoid NS45W datasheet in solenoid section of catalog
Standard Nominal Voltage
Limiting Current
Nominal Power
Limiting Power
Nominal Resistance
Weight of Solenoid
U = 12 VDC U = 24 VDC
IG =1560 mA IG = 780 mA
28 watts
18 watts
5.3 ohms 20.6 ohms
0.79 lb (0.36 kg)
Solenoid Coil Electrical Specifications:
NQPU16D Proportional 3-way Flow Control Cartridge Direct Operated - Pressure Compensated
67
Pro
po
rtiona
l Flow
Co
ntrol V
alves
4
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Performance SpecificationsOil viscosity u = 30 mm2/s
(p3 = 100 bar) Q = f (p) Volume flow pressure characteristics (I = IG)
Δp = f (Q) Pressure drop-volume flow characteristics 1→ 2 (I = 0 mA) Δp = f (Q) Pressure drop-volume flow characteristics 1 → 3 (I = IG)
0 10 20 30 40 50 60 70 80 90 100
K0985
Q [l/min]100
80
60
40
20
0
QN = 63 l/min
QN = 32 l/min
I [%]
100
80
60
40
20
00 50 100 150 200 250 300 350 p [bar]
K0986
Q [l/min]
QN = 63 l/min
QN = 32 l/min
302520151050
0 20 40 60 80 100 Q [l/min]
K0987
p [bar]
0 10 20 30 40 50 60 70 80 Q [l/min]
K0988
p [bar]302520151050
QN = 63 l/min
QN = 32 l/min
NQ P U16 D - MFlow Control Valve NQ
Proportional P
Screw-in Cartridge 1 5/16“— 12 UN U16
3-Way D
Nominal Volume Flow Rate QN
32 l/min 32
63 l/min 63
Nominal Voltage UN
12 VDC 12
24 VDC 24
Without Coil* X5
Slip-on Coil Metal housing round W
ConnectionExecution
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Sealing Material NBR 1
Manual Override M
Configurator
* For ordering information please see Solenoid Coils section of this catalog, NS45W
NQPU16D Proportional 3-way Flow Control Cartridge Direct Operated - Pressure Compensated
Pro
po
rtiona
l Flow
Co
ntrol V
alves
68
4
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NQPU16D Proportional 3-way Flow Control Cartridge Direct Operated - Pressure Compensated
22,6
62,2
2,9 95,2 75,8
171
(1)
(3) (2)
1-5/
16"-
12U
N-2
A
s36
3
2
1
1-5/16"-12UN-2B
10
15
17 18 50
70
80
20
6090
22,6
62,2
2,9 95,2 75,8
171
(1)
(3) (2)
1-5/
16"-
12U
N-2
A
s36
3
2
1
1-5/16"-12UN-2B
10
15
17 18 50
70
80
20
6090
Dimensions
Symbolssimplified detailed
1
2
31
2
3
For detailed cavity drawing and cavity tools see datasheet 5.400.053
Hydraulic ConnectionCavity drawing according to standard
AccessoriesProportional amplifier Connector EN 175301-803Technical explanations Filtration & hydraulic fluids
NPD2, NSD7, NMD2Article no. E209.21102Data sheet 5.400.045 Data sheet 5.400.044
Position Article Description
10 NS45W2350- Solenoid Coil NS45W 23x50
20 C274.15101 Knurled nut M23 x 1.5 x 19.7
15 A803.25100 A209.23133
HB4.5 manual override HB0 Screw plug
17 S220.16122 O-ring ID 22.22x 2.62 (NBR)
18 S220.16120 O-ring ID 21.95 x 1.78 (NBR)
20 C274.15101 Knurled nut M23 x 1.5 x 19.7
50 S220.16198 S620.16196
O-ring ID 29.82 x 2.62 (NBR)O-ring ID 29.82 x 2.62 (FMK)
60 S220.16138S620.16138
O-ring ID 23.81 x 2.62 (NBR) O-ring ID 23.81 x 2.62 (FMK)
70 S220.16136 S620.16136
O-ring ID 23.52 x 1.78 (NBR) O-ring ID 23.52 x 1.78 (FKM)
80 S329.04197 Backup ring RD 24.5 x 29 x 1.4
90 S329.04176 Backup ring RD 24.1 x 27 x 1.4
Parts List
Features• Linear pressure adjustment characteristics
• Precise control
• High repeatability
• 12 and 24v DC control
Norgren’s proportional pressure reducing cartridge valves are ideal for use in hydraulic systems that need frequent and precise adjustment. They pair perfectly with Norgrens pilot operated proportional directional control valves.
Proportional Pressure Reducing Valves
70
Pro
po
rtiona
l Pressure R
educing
Va
lves
5
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Designation: Proportional spool valve
Construction: Screw-in cartridge for cavity
Operation: Proportional solenoid
Mounting: Screw-in cartridge type M16 x 1.5
Mounting Position: Any, preferable horizontal
Fastening Torque: MD = 30 Nm Screw-in cartridge MD = 5 Nm knurled nut MD = 9.5 Nm HB0 MD = 5.5 Nm HB4.5
Nominal Size: M16 x 1.5 according to Norgren standard
NMPM16 Proportional Pressure Reducing Cartridge Direct Operated
» Direct operated, » Qmax = 16.12 gpm (61 l/min) » pmax = 3045 psi (210 bar), pmax = 5076 psi (350 bar) » pNred max = 580 psi (40 bar) » M16 X 1.5
Technical DataWeight:0.99 lb (0.45 kg)
Ambient Temperature: -13 to +122 °F (-25 to +50 °C)
Seal Material: NBR or FKM (Viton) as standard
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Relative Duty Factor: 100 % ED / DF
Fluid: Mineral oil, other fluid on request
Contamination Efficiency: ISO 4406:1999, class 18/16/13
Filtration: Required filtration grade ß 6 to 10 ≥ 75
Viscosity Range: 12 mm2/s to 320 mm2/s
Fluid Temperature: -13 to +150 °F (-25 to +70 °C) NBR -4 to +150 °F (-20 to +70 °C) FKM
Flow Direction: See Symbols
Operating Pressure: pmax = 3045 psi (210 bar) pmax = 5076 psi (350 bar)
Nominal Pressure Range: PN red = 362 psi (25 bar), 580 psi (40 bar)
Nominal Flow Range: QN = 0 gpm -1.58 gpm (0 l/min – 6 l/min)
Hysteresis: ≤ 4 % at optimal dither signal
Repeatability: ≤ 1 % at optimal dither signal
Leakage oil: 25 bar execution at psys = 210 bar
pred = 0 bar: < 10 ml/min pred = 25 bar: < 50 ml/min
40 bar execution at psys = 210 bar pred = 0 bar: < 10 ml/min pred = 45 bar: < 40 ml/min
Description Direct operated proportional pressure reducing valve in screw-in cartridge construction for cavity according to Norgren standard. Proportionally to the solenoid current, the solenoid force and the pressure in port A (1) rise. The valve functions practically independently of the pressure in port P (2). Pressure increase in the consumer port A (1) to above the adjusted value, e.g. through an active consumer, is avoided by discharging excess oil to the tank T (3). With the solenoid deenergised, the oil flows freely from consumer port A (1) to port T (3). For the control, Norgren proportional amplifiers are available (see proportional amplifier section under accessories).
Application These valves are used in hydraulic systems where the pressure has to be changed frequently. The electrical remote control in conjunction with process controls allows economical solutions with repeatable processes.
Symbol
(T) 3
(A) 1
(P) 2
Solenoid Coil Connection:
Connection Standard Protection Class
DIN EN 175301 – 803 D: IP 65
Deutsch DT04 – 2P G: IP 67 and 69k See solenoid NS37W datasheet in solenoid section of catalog
Standard Nominal Voltage
Limiting Current
Nominal Power
Limiting Power
Nominal Resistance
Weight of Solenoid
U = 12 VDC U = 24 VDC
IG =1.36 A IG = 0.68 A
27.1 watts
26.5 watts
5.5 ohms 22.7 ohms
0.5 lb (0.23 kg)
Solenoid Coil Connection:
Pro
po
rtiona
l Pressure R
educing
Va
lves
71
5
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NMPM16 Proportional Pressure Reducing Cartridge Direct Operated
NM P M16 D 40 - W 1 M 350Configurator
Performance SpecificationsOil viscosity u = 30 mm2/s
pred = f (Q) Pressure volume flow characteristicsMaximal adjustable pressure25 bar execution*Limit of the operating range
30
20
10
06 4 2 0 2 4 6
K1145
p [bar]
Q [l/min]A T P A
pred = f (Q) Pressure volume flow characteristicsMaximal adjustable pressure40 bar execution*Limit of the operating range
60
40
20
06 4 2 0 2 4 6
K1144
p [bar]
Q [l/min]A T P A
pred = f (n) Pressure adjustment characteristicsMeasured at Q = 0 l/min (static)25 bar execution**Slightly increased hysteresis
K114725
20
15
10
5
00 10 20 30 40 50 60 70 80 90 100 l [%]
**
p [bar]
pred = f (n) Pressure adjustment characteristicsMeasured at Q = 0 l/min (static)40 bar execution**Slightly increased hysteresis
0 10 20 30 40 50 60 70 80 90 100 l [%]
K1146
p [bar]40
30
20
10
0 **
Pressuring Reducing Valve NM
Proportional P
Screw-in cartridge M16 x 1.5 M16
Direct Operated D
Nominal Pressure Range PN red 40 Bar 40
Nominal Voltage UN
12 VDC 12
24 VDC 24
Without Coil X5
Slip-on Coil Metal housing round W
ConnectionExecution
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Sealing Material NBR 1
Manual Override M
System Pressure Max. 350 bar 350
* For ordering information please see Solenoid Coils section of this catalog, NS37W
72
Pro
po
rtiona
l Pressure R
educing
Va
lves
5
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NMPM16 Proportional Pressure Reducing Cartridge Direct Operated
27.1
W =
37.1
78.3
111.6
76.
8 MD=5.5Nm
MD=5NmM
16x1
.5
(1)
(3) (2)
15
12 17 10 18 50 60 80
s30
M =
35
74.
8
10
MD= 9.5Nm15
HB0
(1)
(2)
(3)
(1)
M16x1 .5
27.1
W =
37.1
78.3
111.6
76.
8 MD=5.5Nm
MD=5Nm
M16
x1.5
(1)
(3) (2)
15
12 17 10 18 50 60 80
s30
M =
35
74.
8
10
MD= 9.5Nm15
HB0
(1)
(2)
(3)
(1)
M16x1 .5
Installation Notes Mounting type Screw-in cartridge type M16 x 1.5
Mounting position Any, preferably horizontal
Tightening torque MD= 30 Nm Screw-in cartridge MD = 5 Nm knurled nut MD = 9.5 Nm HB0 MD = 5.5 Nm HB4.5
Surface Treatment • The cartridge body is gas-nitro carburised• The slip-on coil and the armature tube are zinc nickel coated
Sealing Material NBR or FKM (Viton) as standard, choice in the type code
Manual Override HB4.5Optional: Screw plug (HB0), no actuation possible
Dimensions
For detailed cavity drawing and cavity tools see datasheet 5.400.033
Hydraulic ConnectionCavity drawing according to standard
AccessoriesProportional amplifier Connector EN 175301-803Technical explanations Filtration & hydraulic fluids
NPD2, NSD7, NMD2Article no. E209.21102Data sheet 5.400.045 Data sheet 5.400.044
Position Article Description
10 NS37W1950- Solenoid Coil NS37W 19x50
12 C274.15100 Knurled nut
15 A803.25100A209.23133
HB4.5 manual overrideHB0 Screw plug
17 S210.16187 O-ring ID 18.72 x 2.62 (NBR)
18 S210.16170 O-ring ID 17.17 x 1.78 (NBR)
50 S210.16140 S810.16140
O-ring ID14.00 x 1.78 (NBR)O-ring ID 14.00 x 1.78 (FKM)
60 S200.16193S800.16192
O-ring ID 9.25 x 1.78 (NBR)O-ring ID 9.25 x 1.78 (FKM)
80 S200.16176 S800.16176
O-ring ID 7.65 x 1.78 (NBR) O-ring ID 7.65 x 1.78 (FKM)
Parts List
Features• Reliable and precise operation
• Corrosion resistant
• Integrated manual overide options
• Din and deutsch connectors
• 12 and 24v DC control
Norgren’s solenoid coils are available with your choice of connectors and voltages. Solenoid coil configurations are specic to your select valve family
Solenoid Coils
So
lenoid
Co
ils
74
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NPI29V Proportional Solenoid Coil For NWDPFA3 Valve Family
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 %
Ambient temperature: 122 °F (50 °C)
Fluid Type: Mineral oil, other fluid on request
Corrosion Protection: Salt spray test according to EN ISO 9227: ≥ 1000 h
Seal: Viton, other on request
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580 Plug Plate to ISO 4400/DIN43650
Connection / Power Supply: Over device plug connection to ISO 4400 / DIN 43650,(2P+E), other connections on request
Protection Class to EN 60529: IP65
Switching Cycles: 15000/hr
Mounting Screws: 4 x M3 (Quality 8.8)
Housing: Zinc coated steel housing, other surface treatments on request
Description NPI29V is a proportional solenoid. Its design corresponds to VDE standard 0580. The steel housing is zinc coated as a standard. Static pressure tightness is 5076 psi (350 bar). All O-rings are Viton. The solenoids are fixed to the valve with four screws. Depending on the intended use, the solenoid can be supplied with a plug screw, or with integrated manual override. The connector plate corresponds to ISO 4400 and DIN 43650.
Function The horizontal force-stroke characteristics in the working stroke range means that: • a more or less linear force absorption can be achieved with constant stroke and increasing current absorption. • a more or less linear stroke variation can be achieved when working against a spring and with increasing current absorption.
This ensures that the reference voltage is adequate at the specified reference temperature to reach the limit current in every case. The solenoid coils are available with the standard nominal voltages 12 VDC and 24 VDC.
Application Essential for hydraulic proportional-way-, pressure- and current valves. Due to the risk of overheating, the solenoid must never be used separately. The length of the assembly screws depends on the base material of the body. An O-ring is used for the valve seal. Information on screws and O-rings will be found in the data sheets relating to the valve type. Before changing the plug screw or the screw with integrated manual override, care must be taken to ensure that the solenoid is not under pressure. Risk of injury! The maximum operating pressure is determined by the valve type actually required.
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 8.1 watts 8.8 watts
Limiting Current (50°C) 1.08 A 0.54 A
Limiting Power 13 watts
Nominal Resitance 3.7 ohms 15.2 ohms
Inductivity 12 mH 45
Number of Windings 645 1310
Total Stroke 2.5 mm
Working Stroke 1 mm
Armature Weight 0.03 lb (0.014 kg)
Weight of Solenoid 0.46 lb (0.21 kg)
75
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NPI29V Proportional Solenoid Coil For NWDPFA3 Valve Family
PerformanceF = f (s) Force-stroke characteristics
F [N] F [N]
s [mm]
K011035
30
25
20
15
10
5
0
35
30
25
20
15
10
5
00 0.5
0 20 40 60 80 1001 1.5 2 2.5
1 .2 lG
1 .0 lG
1 .8 lG
0.6 lG
0.4 lG
0.2 lG
= Working stroke
K0111
I [%]G
NPI 29 V MCoil Execution NPI
Housing Size 29 mm 29
Solenoid Completely Potted V
Nominal Voltage UN
12 VDC 12
24 VDC 24
Manual Override With mounted manual override M
Configurator
So
lenoid
Co
ils
76
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NPI29V Proportional Solenoid Coil For NWDPFA3 Valve Family
Accessoires Plug HB0 Item No. A209.23133 (data sheet 5.400.039) Plug with integrated manual override HB4.5 Item No. A803.25100 (data sheet 5.400.039) Plug grey Item No. E209.21101 Plug black Item No. E209.21102 Technical explanation see data sheet 5.400.042
M8
x 0
.75
3542
55
1.7 2329
61.6
6.3*
∅ 2
0
∅ 6
.5∅
4.5
3.4
6839
.5∅
27∅
2.9
3.3
5 (∅
1.5)
Dimensions
77
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NE37V Proportional Solenoid Coil For NWDPFA4 and NSDSM Valve Families
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100% DF / ED combined with armature tube and valve
Ambient temperature: 24.8°F...+122 °F
(-20...+50 °C) Corrosion
Protection: Salt spray test according to EN ISO 9227: ≥ 200 h
Solenoid Type: Proportional, wet pin push type, pressure tight, Class H
Solenoids Standard: DIN VDE 0580
Description The slip-on solenoid coil NE37V19 is available in 2 sizes and in three different connection versions (see type code). The construction corresponds to the VDE 0580 standard. The housing is made of steel (zinc- / nickel-coated), the connector socket is made of plastic material.
Function With the combination of an armature tube the function of a switching solenoid or of a proportional solenoid results. The solenoid coils are available with the standard nominal voltages 12 VDC and 24 VDC.
Application Slip-on solenoid coils are utilised in proportional hydraulic valve applications. They are secured to the valve armature tube using supplied knurled nut.
Configurator NE37 V 1 9 50 - Coil Execution NE37
Metal Housing Round with One Sided Collar V
Internal Coil Diameter 19 mm 19
ConnectionExecution
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Coil Length 50 mm 50
Nominal Voltage UN 12 VDC 12
24 VDC 24
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Limiting Current IG = 1.20A IG = 0.63 A
Nominal Power 22 watts
Limiting Power 16 watts 15 watts
Nominal Resistance 6.4 ohms 27.2 ohms
Number of Windings 780 1560
Weight of Solenoid 0.44 lb (0.20 kg)
Caution: Because of the danger of over-heating the solenoid coil must only be commissioned together with an armature tube as well as with a valve.
So
lenoid
Co
ils
78
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NE37V Proportional Solenoid Coil For NWDPFA4 and NSDSM Valve Families
Dimensions / Execution
Ø19Ø 37
47.5
40 /
50
40 /
50
40 /
50
47.5
55.3
Ø 23.2
Ø19Ø 37
47.5
40 /
50
40 /
50
40 /
50
47.5
55.3
Ø 23.2
Ø19Ø 37
47.5
40 /
50
40 /
50
40 /
50
47.5
55.3
Ø 23.2
Technical explanation see data sheet 5.400.042
Execution: NE37V19D50 • 3-poles 2 P+E • Protection class IP 65 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NE37V19J50 • 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 66 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NE37V19G50• 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 67 and 69 K with corresponding mating
connector (not included in delivery) and professional assembly.
79
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NE45W Solenoid Coil For NWDPFA6 Valve Family
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 % DF / ED combined with armature tube and valve
Corrosion Protection: Salt spray test according to EN ISO 9227: ≥ 1000 h
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Ambient temperature: See temperature curve at right
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
K4252
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130
130
120
110
100
90
80
70
60
50
40
130
120
110
100
90
80
70
60
50
40
1
1
2
2
3
4
Dut
y fa
ctor
in %
Ambient temperature in °C
1 Duty factor at nominal voltage2 Duty factor at 110 % nominal voltage3 Max. voltage in % for 100 % duty factor4 Min. voltage in % for proportional
limiting current at 100% duty factor
Vol
tage
in %
Description The slip-on solenoid coil NE45W23 is available in three different connection versions (see type code). The construction corresponds to the VDE 0580 standard. The housing is made of steel (zinc- / nickel-coated), the connector socket is made of plastic material.
Function With the combination of an armature tube the function of a switching solenoid or of a proportional solenoid results. The solenoid coils are available with the standard nominal voltages 12 VDC ,24 VDC, 115 VAC and 230VAC.
Application Slip-on solenoid coils are utilised in proportional hydraulic valve applications. They are secured to the valve armature tube using supplied knurled nut.
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 30.9 watts 31.8
Limiting Current 1.715 A 0.88 A
Limiting Power 20.6 watts 21.2 watts
Nominal Resistance 4.66 ohms 18.1 ohms
Number of Windings 620 1250
Weight of Solenoid 0.72 lb (0.33 kg)
Caution: Because of the danger of over-heating the solenoid coil must only be commissioned together with an armature tube as well as with a valve.
So
lenoid
Co
ils
80
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NE45W Solenoid Coil For NWDPFA6 Valve Family
56,245Ø
50
23.03Ø
50
65
50
63,2
56,245Ø
50
23,03Ø
50
65
50
63,2
56,245Ø
50
23,03Ø
50
65
50
63.2
Technical explanation see data sheet 5.400.042
Execution: NE45W23D50 • 3-poles 2 P+E • Protection class IP 65 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NE45W23J50 • 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 66 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NE45W23G50• 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 67 and 69 K with corresponding mating
connector (not included in delivery) and professional assembly.
Dimensions
NE45W 23 50 -
Coil Execution NE45
Metal Housing Round W
Internal Coil Diameter 23 mm 23
ConnectionExecution
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Coil Length 50 mm 50
Nominal Voltage UN 12 VDC 12
24 VDC 24
Configurator
81
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NE64W Solenoid Coil For NWDPF65A10 Valve Family
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 % DF / ED combined with armature tube and valve
Ambient temperature: -4...+150 °F (-20...+70 °C)
Corrosion Protection: Salt spray test according to EN ISO 9227: ≥ 1000 h
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Description The slip-on solenoid coil NE64W31 is available in three different connection versions (see type code). The construction corresponds to the VDE 0580 standard. The housing is made of steel (zinc- / nickel-coated), the connector socket is made of plastic material.
Function With the combination of an armature tube the function of a switching solenoid or of a proportional solenoid results. The solenoid coils are available with the standard nominal voltages 12 VDC and 24 VDC.
Application The solenoid coils are mainly utilised in hydraulic applications.
NE64W 31 72 -
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 39 watts 38 watts
Limiting Current 2.25 A 1.105 A
Limiting Power 27.1 watts 26.5watts
Nominal Resistance 3.7ohms 15.2 ohms
Weight of Solenoid 2.2 lb (1.0 kg)
Caution: Because of the danger of over-heating the solenoid coil must only be commissioned together with an armature tube as well as with a valve.
Coil Execution NE64
Metal Housing Round W
Internal Coil Diameter 31 mm 31
ConnectionExecution
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Coil Length 72 mm 72
Nominal Voltage UN 12 VDC 12
24 VDC 24
Configurator
So
lenoid
Co
ils
82
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NE64W Solenoid Coil For NWDPF65A10 Valve Family
Ø 3172
Ø 64
72
72
82,9
7272
Ø 31
72
Ø 64
72
72
82,9
7272
Ø 31
72
Ø 64
72
72
82,9
7272
↓ Valve side
↓ Valve side
↓ Valve side
Execution: NE64W31D72• 3-poles 2 P+E • Protection class IP 65 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NE64W31J72• 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 66 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NE64W31G72• 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 66 with corresponding mating connector
(not included in delivery) and professional assembly.
Dimensions / Execution
Technical explanation see data sheet 5.400.042
83
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NS37W Solenoid Coil For NVPF90A10 and NMPM16 Valve Families
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 % DF / ED combined with armature tube and valve
Ambient temperature: -4...+150 °F (-20...+70 °C)
Corrosion Protection: Salt spray test according to EN ISO 9227: ≥ 1000 h
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Description The slip-on solenoid coil NS37W19 is available in three different connection versions (see type code). The construction corresponds to the VDE 0580 standard. The housing is made of steel (zinc- / nickel-coated), the connector socket is made of plastic material.
Function With the combination of an armature tube the function of a switching solenoid or of a proportional solenoid results. The solenoid coils are available with the standard nominal voltages 12 VDC and 24 VDC.
Application Slip-on solenoid coils are utilised in proportional hydraulic valve applications. They are secured to the valve armature tube using supplied knurled nut.
Caution: Because of the danger of over-heating the solenoid coil must only be commissioned together with an armature tube as well as with a valve.
Standard Nominal Voltage
Limiting Current
Nominal Power
Limiting Power
Nominal Resistance
Number of Windings
Weight of Solenoid
U = 12 VDC U = 24 VDC
IG = 1.36 A IG = 0.68 A
26 watts
16 watts
5.5 ohms 22.7 ohms
705 1410
0.50 lb (0.23 kg)
NS37 W19 50 -
Coil Execution NS37
Metal Housing Round W
Internal Coil Diameter 19 mm 19
ConnectionExecution
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Coil Length 50 mm 50
Nominal Voltage UN 12 VDC 12
24 VDC 24
Configurator
So
lenoid
Co
ils
84
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NS37W Solenoid Coil For NVPF90A10 and NMPM16 Valve Families
Ø19.03
48.250
37Ø
57
5050
55,2
Ø19,03
48,2
50
37Ø
57
5050
55,2
Ø19,03
48,2
50
37Ø
57
5050
55.2
Execution: NS37W19D50• 3-poles 2 P+E • Protection class IP 65 with corresponding mating connector
(not included in delivery) and professional assembly.
Technical explanation see data sheet 5.400.042
Execution: NS37W19J50• 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 66 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NS37W19G50• 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 67 and 69 K with corresponding mating
connector (not included in delivery) and professional assembly.
Dimensions
85
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NE37W Solenoid Coil For NWDPU10 Valve Family
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100% DF / ED combined with armature tube and valve
Ambient temperature: -4...+150 °F (-20...+70 °C)
Corrosion Protection: Salt spray test according to EN ISO 9227: ≥ 200 h
Solenoid Type: Proportional, wet pin push type, pressure tight, Class H
Solenoids Standard: DIN VDE 0580
Description The slip-on solenoid coil NS37W16 is available in three different connection versions (see type code). The construction corresponds to the VDE 0580 standard. The housing is made of steel (zinc- / nickel-coated), the connector socket is made of plastic material.
Function With the combination of an armature tube the function of a switching solenoid or of a proportional solenoid results. The solenoid coils are available with the standard nominal voltages 12 VDC ,24 VDC, 115 VAC and 230VAC.
Application Slip-on solenoid coils are utilised in proportional hydraulic valve applications. They are secured to the valve armature tube using supplied knurled nut.
NE37 W 16 40 -
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 20.5 watts
Limiting Current 1.16 A 0.58 A
Limiting Power 14 watts
Nominal Resistance 7 ohms 28 ohms
Number of Windings 710 11420
Weight of Solenoid 0.48 lb (0.22 kg)
Caution: Because of the danger of over-heating the solenoid coil must only be commissioned together with an armature tube as well as with a valve.
Coil Execution NE37
Metal Housing Round W
Internal Coil Diameter 16 mm 16
ConnectionExecution
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Coil Length 40 mm 40
Nominal Voltage UN 12 VDC 12
24 VDC 24
Configurator
So
lenoid
Co
ils
86
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NE37W Solenoid Coil For NWDPU10 Valve Family
Dimensions / Execution
••
•••
•••
Ø 1647.5
Ø 37
40
47.5
40
55.3
40
Ø 1647.5
Ø 37
40
47.5
40
55.3
40
Ø 1647.5
Ø 37
40
47.5
40
55.3
40
Technical explanation see data sheet 5.400.042
Execution: NE37W16D40 • 3-poles 2 P+E • Protection class IP 65 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NE37W16J40 • 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 66 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NE37W16G40• 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 67 and 69 K with corresponding mating
connector (not included in delivery) and professional assembly.
87
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 %
Ambient temperature: 122 °F (50 °C)
Fluid Type: Mineral oil, other fluid on request
Seal: Viton, other on request
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: VDE standard 0580Plug Plate to ISO 4400/DIN43650
Connection / Power Supply: Over device plug connection to ISO 4400 / DIN 43650,(2P+E), other connections on request
Protection Class to EN 60529: IP65
Switching Cycles: 15000/hr
Mounting Screws: 4 x M3 (Quality 8.8)
Housing: Zinc coated steel housing, other surface treatments on request
Corrosion Protection: Salt spray test according to EN ISO 9227: ≥ 1000 h
Description The NSIS29V is a switching solenoid. Its design corresponds to VDE standard 0580. The steel housing is zinc coated as a standard. Static pressure tightness is 350 bars. All o-rings are Viton. The solenoids are fixed to the valve with four screws. Depending on the intended use, the solenoid can be supplied with a plug screw, or with integrated manual override. Theconnector plate corresponds to ISO 4400 and DIN 43650.
Function When the solenoid is energised with the specified nominal voltage, the armature moves from the starting position of its stroke (s = 2,5 mm)to the end position (s = 0 mm). The switching time is essentially dependent on the application. The power-stroke characteristics are designed to suit the requirements of hydraulic valves. AC versions include an electronic rectifier integrated into the connector plate. In this way maximum performance is assured.
Application Essential for hydraulic directional and poppet valves. Because of the risk of overheating, the solenoid must never be used separately. Thelenght of the fixing screws depends on the base material of the body. An o-ring is used for the valve seal. Information on screws and o-rings will be found in the data sheets relating to the valves concerned. Before changing the plug screw or the screw with integrated manual override, care must be taken to ensure that the solenoid is not under pressure. Risk of injury! The maximum operating pressure is determinded by the valve actually used.
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 15 Watts
Nominal Resitance 10 ohms 40 ohms
Inductivity 17 mH
Number of Windings 740 1490
Total Stroke 2.5 mm
Working Stroke 1 mm
Armature Weight 0.03 lb (0.014 kg)
Weight of Solenoid 0.46 lb (0.21 kg)
NSIS29V Solenoid Coil For NB3S Valve Family
So
lenoid
Co
ils
88
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSIS29V Solenoid Coil For NB3S Valve Family
PerformanceF = f (s) Force-stroke characteristics
Accessories Plug HB0 Item No. A209.23133 (data sheet 5.400.039) Plug with integrated Item No. A803.25100 (data sheet 1.1-300)
Plug grey Item No. E209.21101 Plug black Item No. E209.21102
Technical explanation see data sheet 5.400.042
manual override HB4.5
Dimensions
NSI S 29V OCoil Execution NSI
Super S
Housing Size 35 mm 29
Solenoid Completely Potted V
Nominal Voltage UN
12 VDC 12
24 VDC 24
Manual Override with mounted screw plug O
Configurator
89
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSIS35V Solenoid Coil For NB4S Valve Family
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 %
Ambient temperature: 122 °F (50 °C)
Fluid Type: Mineral oil, other fluid on request
Seal: Viton, other on request
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: VDE standard 0580Plug Plate to ISO 4400/DIN43650
Connection / Power Supply: Over device plug connection to ISO 4400 / DIN 43650,(2P+E), other connections on request
Protection Class to EN 60529: IP65
Switching Cycles: 15000/hr
Mounting Screws: 4 x M3 (Quality 8.8)
Housing: Zinc coated steel housing, other surface treatments on request
Description The NSIS35V is a switching solenoid. Its design corresponds to VDE standard 0580. The steel housing is zinc coated as a standard. Static pressure tightness is 5076 psi (350 bar). All O-rings are Viton. The solenoids are fixed to the valve with four screws. Depending on the intended use, the solenoid can be supplied with a plug screw or with integrated manual override. The connector plate corresponds to ISO 4400 and DIN 43650.
Function When the solenoid is energized with the specified nominal voltage, the armature moves from the starting position of its stroke (s = 4 mm) to the end position (s = 0 mm). The switching time is essentially dependent on the application. The power stroke characteristics are designed to suit the requirements of hydraulic valves. AC versions include an electronic rectifier integrated into the connector plate. In this way maximum performance is assured.
Application Essential for hydraulic directional and poppet valves. Due to the risk of overheating, the solenoid must never be used separately. The length of the assembly screws depend on the base material of the body. An O-ring is used for the valve seal. Information on screws and O-rings will be found in the data sheets relating to the valve types. Before changing the plug screw or the screw with integrated manual override, care must be taken to ensure that the solenoid is not under pressure. Risk of injury! The maximum operating pressure is determined by the valve required.
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 22 Watts
Nominal Resitance 7.2 ohms 25 ohms
Inductivity 14 mH 60 mH
Number of Windings 800 1550
Total Stroke 4 mm
Working Stroke 1.7 mm
Armature Weight 0.052 lb (0.024 kg)
Weight of Solenoid 0.99 lb (0.45 kg)
So
lenoid
Co
ils
90
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSIS35V Solenoid Coil For NB4S Valve Family
PerformanceF = f (s) Force-stroke characteristics
* Solenoid energized (s = 0 mm)
53
59.2
2.9
32 45.5
8M
x0.7
5
2.2
74
70
4.5
28
35
6.25
9.9*
4
8
5.25
( ∅1.
5)
1: U = 100 % UN Reference temperature = 20 °C (22W)2: U = 90 % UN Reference temperature = 50 °C
Solenoid in operating temperature (15W)
The values refer to UN = 24VDC.With other nominal voltages deviations can occur.For curve 2 the solenoid has been mounted on a body 38 x 54.
F [N]
s [mm]
K01 1 5
1
2
130
120
110
100
90
80
70
60
50
40
30
20
10
00 0.5 1 1.5 2 2.5 3 3.5 4
Accessories Plug HB0 Item No. A209.23133 (data sheet 5.400.039) Plug with integrated Item No. A803.25100 (data sheet 1.1-300)
Plug grey Item No. E209.21101 Plug black Item No. E209.21102
Technical explanation see data sheet 5.400.042
manual override HB4.5
Dimensions
NSI S 35 V MCoil Execution NSI
Super S
Housing Size 35 mm 35
Solenoid Completely Potted V
Nominal Voltage UN
12 VDC 12
24 VDC 24
Manual Override With mounted manual override M
Configurator
91
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSIS45V Solenoid Coil For NA6S Valve Family
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 %
Ambient temperature: 122 °F (50 °C)
Fluid Type: Mineral oil, other fluid on request
Seal: Viton, other on request
Corrosion Protection: Salt spray test according to EN ISO 9227:≥ 1000 h
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580 Plug Plate to ISO 4400/DIN43650
Connection / Power Supply: Over device plug connection to ISO 4400 / DIN 43650,(2P+E), other connections on request
Protection Class to EN 60529: IP65
Switching Cycles: 15000/hr
Mounting Screws: 4 x M3 (Quality 8.8)
Housing: Zinc coated steel housing, other surface treatments on request
Description The NSIS45V is a switching solenoid. Its design corresponds to VDE standard 0580.The steel housing is zinc coated as a standard. Static pressure tightness is 5075 PSI (350 bar). All O-rings are Viton. The solenoids are fixed to the valve with four screws. Depending on the intended use, the solenoid can be supplied with a plug screw, or with integrated manual override. The connector plate corresponds to ISO 4400 and DIN 43650.
Function When the solenoid is energized with the specified nominal voltage, the armature moves from the starting position of its stroke (s = 5.5 mm) to the end position (s = 0 mm). The switching time is essentially dependent on the application. The power stroke characteristics are designed to suit the requirements of hydraulic valves. AC versions include an electronic rectifier integrated into the connector plate. In this way maximum performance is assured.
Application Essential for hydraulic directional and poppet valves. Due to the risk of overheating, the solenoid must never be used separately. The length of the assembly screws depend on the base material of the body. An O-ring is used for the valve seal. Information on screws and O-rings will be found in the data sheets relating to the valve types. Before changing the plug screw or the screw with integrated manual override, care must be taken to ensure that the solenoid is not under pressure. Risk of injury! The maximum operating pressure is determined by the valve required.
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 22 Watts
Nominal Resitance 5 ohms 21.8 ohms
Inductivity 19 mH 82 mH
Number of Windings 770 1560
Total Stroke 5.5 mm
Working Stroke 2.5 mm
Armature Weight 0.096 lb (0.044 kg)
Weight of Solenoid 1.67 lb (0.76kg)
So
lenoid
Co
ils
92
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSIS45V Solenoid Coil For NA6S Valve Family
Accessoires Plug HB0 Item No. A209.23133 (data sheet 1.1-300) Plug with integrated manual override HB6 Item No. 253.8001 (data sheet 1.1-300) Plug grey Item No. E209.21101 Plug black Item No. E209.21102 Rectifier Plug Grey Item No. 219.2105 Rectifier Plug Black Item No. 219.2106
Technical explanation see data sheet 5.400.042
* Solenoid energized (s= 0 mm)
8M
x0.7
5
54.5 2.2
64.2
74
4.9
26 55.5
84
5.5
5.5
35,36
45
6
11.2
10*
( ∅2)
6.5
9.8
13.6
PerformanceF = f (s) Force-stroke characteristics
1: U = 100 % UN Reference temperature = 20 °C (22W)2: U = 90 % UN Reference temperature = 50 °C
Solenoid in operating temperature (15W)
The values refer to UN = 24VDC.With other nominal voltages deviations can occur.For curve 2 the solenoid has been mounted on a body 36 x 64.
F [N]
s [mm]
K0062
0 1 2 3 4 5
160
140
120
100
80
60
40
20
0
1
2
Dimensions
NSI S 45 V MCoil Execution NSI
Super S
Housing Size 45 mm 45
Solenoid Completely Potted V
Nominal Voltage UN
12 VDC 12
24 VDC 24
Manual Override With mounted manual override M
Configurator
93
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
» M40 to Din VDE 0580 » Plug plate to ISO 4400 / DIN 43650» Protection class IP 65
Technical DataCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 %
Ambient temperature: 122 °F (50 °C)
Fluid Type: Mineral oil, other fluid on request
Seal: Viton, other on request
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: VDE standard 0580Plug Plate to ISO 4400/DIN43650
Connection / Power Supply: Over device plug connection to ISO 4400 / DIN 43650,(2P+E), other connections on request
Protection Class to EN 60529: IP65
Switching Cycles: 15000/hr
Mounting Screws: 4 x M3 (Quality 8.8)
Housing: Zinc coated steel housing, other surface treatments on request
Corrosion Protection: Salt spray test according to EN ISO 9227: ≥ 1000 h
Description The SIS45DV-M40 is a switching solenoid. Its design corresponds to VDE standard 0580. The steel housing has a zinc coated finish as standard. Static pressure tightness is 350 bars. All o-rings are Viton. The solenoids are fixed to the valve with eight screws. The solenoid will be supplied with a plug screw as standard, or depending on the intended use, with integrated manual override. The connector plate corresponds to ISO 4400 and DIN 43650.
Function When the solenoid is energised with the specified nominal voltage, the armature moves from the starting position of its stroke (s = 5,5 mm) to the end position (s = 0 mm). The switching time is essentially dependent on the application. The power-stroke characteristics are designed to suit the requirements of hydraulic valves. AC versions include an electronic rectifier integrated into the connector plate. In this way maximum performance is assured.
Application Essential for hydraulic poppet valves. Because of the risk of overheating, the solenoid must never be used separately. The lenght of the fixing screws epends on the base material of the body. An o-ring is used for the valve seal. Information on screws and o-rings will be found in the data sheets relating to the valves concerned. Before changing the plug screw or the screw with integrated manual override, care must be taken to ensure that the solenoid is notunder pressure. Risk of injury! The maximum operating pressure is determinded by the valve actually used.Risk of injury! The maximum operating pressures determined by the valve type actually required.
Standard Nominal Voltage U = 12 VDC U = 24 VDC
Nominal Power 15 Watts
Nominal Resitance 10 ohms 40 ohms
Inductivity 17 mH
Number of Windings 740 1490
Total Stroke 2.5 mm
Working Stroke 1 mm
Armature Weight 0.03 lb (0.014 kg)
Weight of Solenoid 0.46 lb (0.21 kg)
NSIS45DV-M40 Solenoid Coil For NA6S43 Valve Family
So
lenoid
Co
ils
94
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSIS45DV-M40 Solenoid Coil For NA6S43 Valve Family
PerformanceF = f (s) Force-stroke characteristics
Solenoids
Wandfluh AG Tel. +41 33 672 72 72 E-mail: [email protected] Illustrations not obligatory Data sheet no. Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.1-127E 1/2 CH-3714 Frutigen Edition 06 20
type code SI S 45D V - - M40 - #
Solenoid, Industrial executionSuperDouble solenoid, 45mmSolenoid completly pottedNominal voltage UN 12 VDC G12 115 VAC R115 ∗ 24 VDC G24 230 VAC R230 ∗
AC = 50 to 60 Hz∗ Rectifier integrated in the plug plateOther nominal voltages and nominal power on request
Special sealing against the valve
with mounted screw plug (data sheet 1.1-300) HB0with mounted manual override (data sheet 1.1-300) HB6with mounted special manual override (data sheet 1.1-310) H...
Design-Index (Subject to change)
dimensions
solenoid sis45dV-…-m40to Vde 0580plug plate to iso 4400 / din 43650protection class ip65
descRiptionThe SIS45DV-M40 is a switching solenoid. Its design corresponds to VDE standard 0580. The steel housing has a zinc coated finish as standard. Static pressure tightness is 350 bars. All o-rings are Viton. The solenoids are fixed to the valve with eight screws. The solenoid will be supplied with a plug screw as standard, or depending on the intended use, with integrated manual override. The connector plate corre-sponds to ISO 4400 and DIN 43650.
functionWhen the solenoid is energised with the speci-fied nominal voltage, the armature moves from the starting position of its stroke (s = 5,5 mm) to the end position (s = 0 mm). The switching time is essentially dependent on the application. The power-stroke characteristics are designed to suit the requirements of hydraulic valves. AC versions include an electronic rectifier integrated into the connector plate. In this way maximum performance is assured.
AppLicAtionEssential for hydraulic poppet valves. Because of the risk of overheating, the solenoid must never be used separately. The lenght of the fixing screws depends on the base material of the body. An o-ring is used for the valve seal. Information on screws and o-rings will be found in the data sheets relating to the valves concerned. Before changing the plug screw or the screw with integrated manual override, care must be taken to ensure that the solenoid is not under pressure. Risk of injury! The maximum operating pressure is determinded by the valve actually used.
* Solenoid energised (s= 0 mm)
64,2 2,23,5
74
4,9
26
130
91 101,
5
35,36
45
5,5
10*
9
9,8
6,8
5,5
( ∅2)
10
20
Solenoids
Wandfluh AG Tel. +41 33 672 72 72 E-mail: [email protected] Illustrations not obligatory Data sheet no. Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.1-127E 2/2 CH-3714 Frutigen Edition 06 20
AccessoiRes
cHARActeRisticsStatic pressure tightness 350 bar (seal diameter of valve max. 25 mm) With seal diameter of valve = 26 mm: Static pressure tightness = 315 bar Coil winding insulation class HConnection / Power supply Over device plug connection to ISO 4400 / DIN 43650, (2P+E), other connections on request.Protection class EN 60 529 IP65Relative duty factor 100 %Reference temperature 50 °CSeal Viton, other on requestFluid Mineral oil, other fluid on requestSwitching cycles 15 000/hMounting screws 8 x M5 (Quality 8.8)Housing Zinc coated steel housing, other surface treatments on request.
dc AcTotale stroke (mm) 5,5 5,5Working stroke (mm) 2,5 2,5Nominal power (W) 60 (VA) 70Armature weight (kg) 0,044 0,044Solenoid weight (kg) 1,650 1,650Voltage range (VDC) 10-250 (VAC) 80-250 ∗
∗ For AC voltages below 80 VAC DC solenoids plus rectifier plugs are available. 21 VDC to 24 VAC 32 VDC to 36 VAC 36 VDC to 42 VAC 42 VDC to 48 VAC
pARts List
Plug HB0 * Article No. 239.2033
Plug with integrated manual override HB6 * Article No. 253.8001 * acc. data sheet 1.1-300
Special manual override see data sheet 1.1-310
Plug grey Article No. 219.2001Plug black Article No. 219.2002 Rectifier plug grey Article No. 219.2105Rectifier plug black Article No. 219.2106
1: U = 100 % UN Reference temperature = 20 °C (30W)2: U = 90 % UN Reference temperature = 50 °C Solenoid in operating temperature (19W)The values refer to UN = 24 VDC. With other nominal voltages deviations can occur.For curve 2 the solenoids has been mounted on a body 46 x 92 x 64.
12Vdc 24Vdc 115VAc 230VAcNominal resistance (Ω) 5 21,8 445 1'400Number of windings (-) 770 1’560 7’000 13’000Inductivity (mH) 10 41
Technical explanation see data sheet 1.1-400
peRfoRmAncesF = f (s) Force-stroke characteristics (Valid for single coil)
Position Article Description
10 212.0506 Washer 20 160.6456 O-ring ID 15,60 x 1,78
s [mm]
F [N]K0062
0 1 2 3 4 5
160
140
120
100
80
60
40
20
0
1
2
Dimensions
NSI S 45D V M40 - OCoil Execution NSI
Super S
Housing Size 45 mm 45D
Solenoid Completely Potted V
Nominal Voltage UN
12 VDC 12
24 VDC 24
Special sealing against the valve M40
Manual Override with mounted screw plug O
Configurator
AccessoriesPlug HB0 Item No. A209.23133 (data sheet
5.400.039)
Plug with integrated manual override HB6
Item No. 253.8001 (data sheet 5.400.039)
Special manual override See data sheet (data sheet 5.400.040)
Plug grey Item No. E209.21101
Plug black Item No. E209.21102
Rectifier plug grey Item No. 219.2105
Rectifier plug black Item No. 219.2106
Technical explanation see data sheet 5.400.042
95
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory AutomationFactory Automation
» Din VDE 0580 » Protection class IP 65 / 67 / 69K
SpecificationsCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 %
Ambient temperature: 122 °F (50 °C)
Fluid Type: Mineral oil, other fluid on request
Seal: Viton, other on request
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580 Plug Plate to ISO 4400/DIN43650
Connection / Power Supply: Over device plug connection to ISO 4400 / DIN 43650,(2P+E), other connections on request
Protection Class to EN 60529: IP65
Switching Cycles: 15000/hr
Mounting Screws: 4 x M6 (Quality 8.8)
Housing: Zinc coated steel housing, other surface treatments on request
Standard Nominal Voltage
Nominal Power
Limiting Power
Nominal Resistance
Inductivity
Number of Windings
Total Stroke
Working Stroke
Armature Weight
Weight of Solenoid
U = 12 VDC U = 24 VDC U=125 VDC U = 115 VAC U = 230 VAC
40 watts 46 VA
13 watts
4 ohms 16.5 ohms 400 ohms 260 ohms 920 ohms
17 mH 65 mH 1625 – –
780 1580 7760 5930 11400
8.5 mm
4 mm
0.22 lb (0.102 kg)
4.18 lb (1.9 kg)
Description The NSIS60V is a switching solenoid. Its design corresponds to VDE standard 0580. The steel housing is zinc coated as a standard. Static pressure tightness is 5076 psi (350 bar). All O-rings are Viton. The solenoids are fixed to the valve with four screws. Depending on the intended use, the solenoid can be supplied with a plug screw or with integrated manual override. The connector plate corresponds to ISO 4400 and DIN 43650.
Function When the solenoid is energized with the specified nominal voltage, the armature moves from the starting position of its stroke (s = 8.5 mm) to the end position (s = 0 mm). The switching time is essentially dependent on the application. The power stroke characteristics are designed to suit the requirements of hydraulic valves. AC versions include an electronic rectifier integrated into the connector plate. In this way maximum performance is assured.
Application Essential for hydraulic directional and poppet valves. Due to the risk of overheating, the solenoid must never be used separately. The length of the assembly screws depends on the base material of the body. An O-ring is used for the valve seal. Information on screws and O-rings will be found in the data sheets relating to the valve types. Before changing the plug screw or the screw with integrated manual override, care must be taken to ensure that the solenoid is not under pressure. Risk of injury! The maximum operating pressure is determined by the valve required.
NSIS60V Solenoid Coil For NA10S Valve Family
So
lenoid
Co
ils
96
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NSIS60V Solenoid Coil For NA10S Valve Family
* Solenoid energized (s = 0 mm)
0.3
81.5
85
2.2
8M
x0.7
5
20
4.9
70.5
99
32
48.08
60
6.5
11.5
10*
8(∅
2)
6.8
15.5
Dimensions
PerformanceF = f (s) Force-stroke characteristics
1: U = 100 % UN Reference temperature = 20 °C (22W)2: U = 90 % UN Reference temperature = 50 °C
Solenoid in operating temperature (25W)
The values refer to UN = 24VDC.With other nominal voltages deviations can occur.For curve 2 the solenoid has been mounted on a body 62 x 93
F [N]
s [mm]
350
300
250
200
150
100
50
00 2 4 6 8 10
K0061
12
Coil Execution NSI
Super S
Housing Size 60 mm 60
Solenoid Completely Potted V
Nominal Voltage UN
12 VDC 12
24 VDC 24
Manual Override With mounted manual override M
Configurator NSI S 60 V M
Accessoires Plug HB0 Item No. A209.23133 (data sheet 1.1-300) Plug with integrated manual override HB8.5 Item No. 253.8001 (data sheet 1.1-300) Plug grey Item No. E209.21101 Plug black Item No. E209.21102 Rectifier Plug Grey Item No. 219.2105 Rectifier Plug Black Item No. 219.2106
Technical explanation see data sheet 5.400.042
97
So
lenoid
Co
ils
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NS45W Solenoid Coil For NQPU16 Valve Family
» Din VDE 0580» Protection class IP 65 / 67 / 69K
SpecificationsCoil Winding Insulation class: H (180 °C)
Relative Duty Factor: 100 % DF / ED combined with armature tube and valve
Ambient temperature: -4...+150 °F (-20...+70 °C)
Corrosion Protection: Salt spray test according to EN ISO 9227: ≥ 1000 h
Solenoid Type: Proportional, wet pin push type, pressure tight
Solenoids Standard: DIN VDE 0580
Description The slip-on solenoid coil NS45W23 is available in three different connection versions (see type code). The construction corresponds to the VDE 0580 standard. The housing is made of steel (zinc-/nickel-coated), the connector socket is made of plastic material.
Function With the combination of an armature tube the function of a switching solenoid or of a proportional solenoid results. The solenoid coils are available with the standard nominal voltages 12 VDC and 24 VDC.
Application Slip-on solenoid coils are utilised in proportional hydraulic valve applications. They are secured to the valve armature tube using supplied knurled nut.
Caution: Because of the danger of over-heating the solenoid coil must only be commissioned together with an armature tube as well as with a valve.
Standard Nominal Voltage
Limiting Current
Nominal Power
Limiting Power
Nominal Resistance
Number of Windings
Weight of Solenoid
U = 12 VDC U = 24 VDC
IG = 1,560 mA IG = 780 mA
28 watts
18 watts
5.3 ohms 20.6 ohms
700 1330
0.79 lb (0.36 kg)
NS45 W 23 50 -
Coil Execution NS45
Metal Housing Round W
Internal Coil Diameter 19 mm 23
ConnectionExecution
Connector socket EN 175301-803 / ISO 440 D
Connector deutsch DT04-2P G
Coil Length 50 mm 50
Nominal Voltage UN 12 VDC 12
24 VDC 24
Configurator
So
lenoid
Co
ils
98
6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NS45W Solenoid Coil For NQPU16 Valve Family
Execution: NS45W23D50• 3-poles 2 P+E • Protection class IP 65 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NS45W23J50• 2-poles 2P • Only for UN ≤ 75 VDC • Protection class IP 66 with corresponding mating connector
(not included in delivery) and professional assembly.
Execution: NS45W23G50• 2-poles 2P • only for UN ≤ 75 VDC • Protection class IP 67 and 69 K with corresponding mating
connector (not included in delivery) and professional assembly.
50
56.2ø45
ø23
63.2
50
65
50
Technical explanation see data sheet 5.400.042
Dimensions / Execution
Features
• Din-rail, direct valve mount and mobile configurations
• Included configuration software
• Available USB interface
• 12 and 24v DC control
Norgren’s electronics are used to control current at the valve for highly sensitive movement and low-hysteresis. Our electronic controllers/amplifiers utilize pulse width modulation and superimposed dither signal to control solenoid positions precisely. Parameters for controllers with SSI or optional digital USB interface can be adjusted through Norgren’s included parameterization software.
Electronics & Accessories
Electro
nics & A
ccesories
100
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
» For 1 proportional or switching solenoid» With cable outlet for free choice of the valve connection plug» Max. 4 analog differential inputs » Max. 8 digital inputs » Fixed command values
Technical Data
Description Digital amplifier module for installation on dome rail for controlling proportional or switching valves with one or two solenoids. The parameterisation takes place by means of menu-controlled parameterisation and diagnostics software «PASO» from Norgren (USB interface) or optionally with a manual operation on the front panel. Separate ramps for up and down as well as fixed adjustable command values are integrated in the amplifier module as standard. The electronics are optionally available with different fieldbus interfaces.
Function The amplifier module has one, resp., two Pulse-Width-Modulated current outputs with superimposed dither signal. The solenoid outputs can also be parameterised for switching solenoids. The analog and digital inputs as well as the digital outputs can be programmed individually. With this device control tasks can be solved in a very simple manner. The fieldbus connection enables reading the command value signal as well as the parameterisation directly via the fieldbus.
Application As snap-on module, the amplifier module is mainly utilized in the industrial field. The module can be mounted on dome-rails. The connection with terminal screws enables commissioning without special tools in a short time. The amplifier module is particularly suitable for applications with additional functions such as ramps, fixed command values, etc. Customer specific requirements can be implemented in a simple manner.
Execution: Module for control cubicle, housing made of plastic
Dimensions:See drawing page 2
Ambient Temperature:-4...+158 °F (-20...+70 °C)
Installation:35 mm domerail according to EN60715
Connections:Screw terminals: max. cable cross-section 2.5 mm2 Protection Class:IP 67 acc. to EN 60 529
Residual Ripple: <10%
Fuse: Low
No-load Current: Approx. 40 mA
Resolution: 10-bit (analog inputs 1 and 2) 16-bit (analog inputs 3 and 4)
Temperature Drift: <1 % at ΔT = 40 °C
Serial Interface: USB (plug type B) for parameterising with «PASO»
Weight:
Max. Current Consumption:No-load current + 1.8 A per solenoid (with 24 VDC) No-load current + 2.3 A per solenoid (with 12 VDC)
Command Value Signal: Selectable by means of software Input 1 and 2 Differential Input not galvanically separated for ground potential difference up to 1.5 V 4…+20 mA / 0…+20 mA 0…+10 V (1- or 2-solenoid version) -10…+10 V (2-solenoid version only) Input 3 (option): Galvanically separated for HART signal
Analog Output: Enhanced amplifier: Voltage output ± 10 VDC Max. output current ± 3 mA
Enhanced amplifier with HART: Current output 0…20 mA Max. output voltage 12 VDC
Input Resistance: Voltage input »18 kΩ Load for current input = 250 Ω Stabilised Output Voltage: 10 VDC (with 24 VDC) 8 VDC (with 12 VDC) Max. load 30 mA
Fieldbus (option) • Device receptacle DSUB, 9-pole,
CANopen, J1939, Profibus • Screw terminals HART • Bus topology Line, differential
signal transmission • Potential separation 500 VDC
Solenoid current: • Minimal current Imin Adjustable 0…950 mA Factory setting 150 mA
• Maximal current Imax Adjustable Imin…1,8 A (with 24 VDC) Imin…2,3 A (with 12 VDC) Factory setting 700 mA
Dither: Frequency adjustable 20…500 Hz Factory setting 100 Hz Level adjustable 0…400 mA Factory setting 100 mA
Digital inputs: Switching threshold high 6…30 VDC Switching threshold low 0…1 VDC Digital input 5 – 7 can be used as frequency input (frequencies 0…5 kHz) and as PWM input (automatic frequency recognition)
Digital Outputs: Low-Side-Switch: Umax = 40 VDC Imax = -700 mA
EMV: Immunity EN 61 000-6-2 Emission EN 61 000-6-4
» For snapping on to dome rail » Adjustable via PC (Optional: manual operation on front panel) » Interface: - Profibus DP - CANopen / J1939 - HART
130 g
220 g
220 g
240 g
Basic amplifer analog
Basic amplifer fieldbus
Enhanced amplifier analog
Enhanced amplifier fiieldbus
Supply Voltage Voltage Range
24 VDC 21...30 V 12 VDC 10.5...15 V
101
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
NS D7 A 3 2 Configurator
The parameterization cable is not included in the delivery (commercially available USB cable, plug type A to plug type B). The amplifier module can be configured by means of Norgren‘s included parameterization software through the USB-interface. In addition, the parameterization software makes a data analysis possible. Optionally the amplifier module is equipped with a manual operation, which enables the setting of the most important parameters by means of rotary selector switch and push-buttons and therefore makes a commissioning of the amplifier module possible without a PC.
Control Cubicle NS
Digital D7
Optional Fieldbus Without fieldbus A
Adjustable with PASO and manual operation 3
Adjustable with Basic Amplifier 0
Enhanced Amplifier 5
Number of Solenoids 2-solenoid Version 2
Supply Voltage12 VDC D12
24 VDC D24
Amplifier
Basic Amplifier without HART Analog input 1 and 2: 10 Bit Resolution A
Basic Amplifier with HART Analog input 1 and 2: 10-bit resolution Analog input 3: 16-bit resolution
B
Enhanced Amplifier Analog input 1 and 2: 10-bit resolution Analog input 3: 16-bit resolution
B
Inputs
Basic Amplifer
Analog input 1 and 2 both current Analog input 3 always current (with HART only)
2
Enhanced AmpliferAnalog input 1 and 3: both voltage Analog input 2 and 4: both current
4
Electro
nics & A
ccesories
102
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
Command value scaling The command value can be applied as a voltage, current or digital signal, or via fieldbus. For every command value, the input utilized can be selected. The scaling takes place via the parameters «Interface» and «Reference». Furthermore every command value can be monitored for a cable break (except for voltage and digital signal). For every command value a dead band can also be set. Optionally one can operate with two command values. The characteristic of these command values can be adjusted.
Fixed command values • For the Basic amplifier, 3 fixed command values are available, which can be selected via 2 digital inputs. • For the Enhanced amplifier, 7 fixed command values are available, which can be selected via 3 digital inputs.
Command value generator For each solenoid output two linear ramps for up and down are available which can be adjusted separately.
HOLD command value (fieldbus only) If via Profibus DP the device is put into the «HOLD» state, the respective command value is activated.
Valve type Here the mode of operation is set. It is also possible to select whether proportional or switching solenoids are to be controlled.
Mode of operation «Command value unipolar (1-sol)» Dependent on a unipolar command value signal (voltage, current), the solenoid is driven (e.g. 0...10V correspond to 0...100% command value, 0...100% command value correspond to Imin...Imax solenoid driver 1).
Mode of operation «Command value unipolar (2-sol)» Dependent on a unipolar command value signal (voltage, current), according to the signal level one of the two solenoids is driven. The switching threshold between the two solenoids as standard is in the middle of the values range of the command value signal (e.g. 0….10V correspond to -100….+100 % command value, -100....0 % command value correspond to Imin….Imax solenoid driver 2, 0….+100 % command value correspond to Imin….Imax solenoid driver 1).
Mode of operation «Command value bipolar (2-sol)» Dependent on a bipolar command value signal (voltage), according to the signal level one of the two solenoids is driven. The switching threshold between the two solenoids as standard is at 0V (e.g. -10….+10V correspond to -100….+100 % command value, -100…0 % command value correspond to Imin….Imax solenoid driver 2, 0….+100 % command value correspond to Imin….Imax solenoid driver 1).
Mode of operation «Command value unipolar (2-sol with DigInp)» Dependent on a unipolar command value signal (voltage, current), the solenoid is driven by solenoid driver 1, when the selected digital input is «not activated», resp. the solenoid by the solenoid driver 2, when the selected digital input is «activated» (e.g. 0….10V correspond to 0….100 % command value, 0....100 % command value correspond to Imin….Imax solenoid driver 1 or 2).
Signal recording The NSD7 amplifier module has a signal recording function. This, by means of PASO, enables the recording of various system signals, such as command value, solenoid currents, etc., which can be represented on a common time axis.
Solenoid driver Two Pulse-Width-Modulated current outputs are available. To each output, a dither signal is superimposed, whereas dither frequency and dither level can be adjusted separately. For each output, the minimum (Imin) and maximum (Imax) current can be adjusted separately. The solenoid outputs can also be configurated as switching outputs. Therewith for each output a power reduction can be adjusted separately.
Optimization of characteristic curve A characteristic curve adjustable per solenoid «Command value input – solenoid current output» enables an optimized (e.g., linearized) characteristic of the hydraulic system.
103
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
Block Diagram Basic Amplifier
Microcontroller
FEPROMRAM
EEPROM
DCDC
X1-5
X1-6
X1-7
+
-
LEDgreen
A
D
A
D
+-
X1-9
X1-10-
+
+-
X1-11
X1-12-
+
X1-1
X1-2
X1-8
UIPWM
A/D
X1-15
X1-16
UIPWM
A/D
X1-13
X1-14
X1-3
X1-4
USB see "Pin Assignment"
X2
+-
X1-21
X1-22-
+(Option)Analogue input 3 • current• HART
HART
X4Fieldbus (option)• CAN / S1939• Profibussee "Pin Assignment"
Option
LED red
LED yellow
Supply voltage
Stabilisedoutput voltage
Analogue input 1voltage
Analogue input 2current
Digital input 1
Digital input 2
Analogue ground
Solenoid A
Solenoid B
Digital output 1
Digital output 2
Electro
nics & A
ccesories
104
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
* x = P only 0...10VDC possible
Configuration Analog inputs Basic amplifier
Type designation Analog input 1 Analog input 2
Voltage Current
Voltage Voltage*
Current Current
Configuration Analog inputs Enhanced amplifier
Type designation Analog inputs
Nr. 1 Nr. 2 Nr. 3 Nr. 4
Voltage Current Voltage Current
Voltage Voltage* Voltage Voltage
Current Current Current Current
Voltage Voltage* Current Current
Current Current Voltage Voltage
Configuration Analog inputs Basic amplifier HART
Type designation Analog inputs
Nr. 1 Nr. 2 Nr. 3
Voltage Current Current
Voltage Voltage Current
Current Current Current
Configuration Analog inputs Enhanced amplifier HART
Type designation Analog inputs
Nr. 1 Nr. 2 Nr. 3 Nr. 4
Voltage Current Current Current
Voltage Voltage Current Voltage
Current Current Current Current
Voltage Voltage Current Current
Current Current Current Voltage
NSD70A0
NSD70A1NSD70A2
NSD70B0
NSD70B1NSD70B1
NSD735B4
NSD735B5NSD735B6
NSD735B7
NSD735B8
NSD7H35B4NSD7H35B4
NSD7H35B5
NSD7H35B6
NSD7H35B7
NSD7H35B8
Function Description
HOLD Fieldbus onlyCommand
value
Commandvalue 1
Commandvalue 2
DigInp
Selection
Enable
Enable
Error
Error
Error
Number Enable Solenoid 2
Solenoid output
Solenoid output
Current measurement
Current measurement
DigInp DigInp DigInp
DigInp
DigInp
Fixedcommand
valuesValvetype
Commandvalue
Scaling
Commandvalue
generator
Solenoiddriver 2
Solenoiddriver 1
The amplifier module can be configured by means of Norgren’s included parameterisation software through the USB-interface. In addition, the parameterisation software makes a data analysis possible. Optionally the amplifier module is equipped with a manual operation, which enables the setting of the most important parameters by means of rotary selector switch and push-buttons and therefore makes a commissioning of the amplifier module possible without a PC.
105
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
Block Diagram Enhanced Amplifier
LED red
LED yellow
DCDC
X1-5
X1-6
X1-7
Supplyvoltage
Stabilised outputvoltage
+
0 VDCLEDgreen
X1-9
X1-10-
+Analogue input 1
X1-11
X1-12-
+Analogue input 2
X1-1Digital input 1
X1-2Digital input 2
Solenoid A
UI
X1-15
X1-16
Solenoid B
UI
X1-13
X1-14
Digital output 1X1-3
Digital output 2X1-4
Microcontroller
FEPROMRAM
EEPROM
PWM
A/D
PWM
A/D
+-
+-
A
Digital output 3
Digital output 4
-Analogue input 3
-
+Analogue input 4
+-
+-
A
D
10-Bit
16-Bit
Stabilised outputvoltage
Ref
SPI
Digital input 3
Digital input 4
Digital input 5
Digital input 6
Digital input 7
Digital input 8
SPIA
D12-Bit
Analogue output
Ref
Analogue groundX1-8
Analogue ground
X1-17
X1-18
X1-19
X1-20
X1-21
X1-22
X1-31
X1-25
X1-26
X1-27
X1-28
+
X1-32
X1-30
X1-23
X1-24
Digital ground
FEPROMRAM
EEPROM
X1-29
X4Fieldbus (Option)• CAN / S1939• Profibussee "Pin Assignment"
USB see "Pin Assignment"
X2
Option
Electro
nics & A
ccesories
106
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
Block Diagram Enhanced Amplifier with HART
DCDC
X1-5
X1-6
X1-7
+
0 VDCLEDgreen
X1-9
X1-10-
+
X1-11
X1-12-
+
X1-1
X1-2
UI
X1-15
X1-16
UI
X1-13
X1-14
X1-3
X1-4
Microcontroller
FEPROMRAM
EEPROM
PWM
A/D
PWM
A/D
+-
+-
A
D
-
-
+
+-
+-
A
D
10-Bit
16-Bit
Ref
SPI
HART
A
D12-Bit
Ref
X1-8
X1-19
X1-20
X1-21
X1-22
X1-23
X1-24
+
X1-17 +
X1-18 -A
H-GND
H-GND
H
A
D16-Bit
X2 USB see "Pin Assignment"
LED red
LED yellow
Supplyvoltage
Stabilised outputvoltage
Analogue input 1
Analogue input 2
Digital input 1
Digital input 2
Solenoid A
Solenoid B
Digital output 1
Digital output 2
Analogue input 3
Analogue input 4
Digital input 3
Digital input 4
Analogue output
Analogue ground
107
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
Connection Example Basic Amplifier
Mode of operation „Command value unipolar (2-sol)“ or „Command value unipolar (2-sol with DigInp)“
Supply voltage +Supply voltage -
Command value presetwith potentiometeron analogue input 1
Enableon digital input 1
Solenoid B activeOnly with mode of operation«command value unipolar(2-Sol with DigInp)»on digital input 2
Fuse Solenoid A
Error active/Solenoid A active
Solenoid B active
Solenoid B
on Digital input 1
Supply voltage +
on Digital input 2
Supply voltage +Supply voltage -
Command value preset 1with potentiometeron analogue input 1
Command value preset 2with potentiometeron analogue input 2
Enableon Digital input 1
Fuse Solenoid A
Error active/Solenoid A active
Solenoid B active
Solenoid B
on Digital input 1
Supply voltage +
on Digital input 2
OptionCommand value presetand enable via fieldbus
X4FieldbusMaster
HARTMaster X1-22
X1-21OptionCommand value presetand enable via HART
OptionCommand value presetand enable via fieldbus
FieldbusMaster X4
HARTMaster X1-22
X1-21OptionCommand value presetand enable via HART
Option
Option
Supply voltage +Supply voltage -
Command value presetwith potentiometeron analogue input 1
Enableon digital input 1
Solenoid B activeOnly with mode of operation«command value unipolar(2-Sol with DigInp)»on digital input 2
Fuse Solenoid A
Error active/Solenoid A active
Solenoid B active
Solenoid B
on Digital input 1
Supply voltage +
on Digital input 2
Supply voltage +Supply voltage -
Command value preset 1with potentiometeron analogue input 1
Command value preset 2with potentiometeron analogue input 2
Enableon Digital input 1
Fuse Solenoid A
Error active/Solenoid A active
Solenoid B active
Solenoid B
on Digital input 1
Supply voltage +
on Digital input 2
OptionCommand value presetand enable via fieldbus
X4FieldbusMaster
HARTMaster X1-22
X1-21OptionCommand value presetand enable via HART
OptionCommand value presetand enable via fieldbus
FieldbusMaster X4
HARTMaster X1-22
X1-21OptionCommand value presetand enable via HART
Option
Option
Mode of operation „Command value unipolar (1-sol)“
Electro
nics & A
ccesories
108
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
Connection Example Enhanced Amplifier
Connection Example Enhanced Amplifier with HARTMode of operation „Command value unipolar (2-sol)“ or „Command value unipolar (2-sol with DigInp)“
Mode of operation „Command value unipolar (2-sol)“ or „Command value unipolar (2-sol with DigInp)“
Ramp off
Fixed command value 1Fixed command value 2Fixed command value 4
Disable solenoid ADisable solenoid B
Supply voltage +Supply voltage -
Command value presetwith potentiometeron analogue input 1
Enableon Digital input 3
Solenoid B active(only with mode of operation 5)on Digital input 4
Fuse Solenoid A
Error active/Solenoid A active
Solenoid B active
Solenoid B
on Digital input 5
on Digital input 6–8
on Digital input 1–2
on Digital input 1
Supply voltage +
on Digital input 2
X1-17
X1-18
X1-19
X1-20
X1-21
X1-22
X1-1
X1-2
OptionCommand value presetand enable via fieldbus
FieldbusMaster X4
Option
X1-22X1-21
Solenoid B active
Solenoid A activeError active/
Solenoid A Solenoid BFuseSupply voltage +Supply voltage -
Supply voltage +
on Digital input 1
on Digital input 2
Command value presetand enable via HARTon analogue input 3
X1-5X1-6
X1-3
X1-4
X1-15X1-16
X1-13X1-14HART
109
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier NSD7
Type: Fieldbus
Type: NSD730 Type: NSD720 Type: NSD735
L
AB
CD
A B
C D45
AB
CD
1 2 3 45 6 7 8
13 14 15 169 10 11 12
ERRO
RFU
NCTIO
NSU
PPLY
FIEL
DBU
S X4
USB
L
AB
CD
A B
C D
Control cubicle module, plastic housing
Mounting on 35 mm dome rail according to EN 60715
Basic amplifier PIN-assignment X1
1 = Digital input 12 = Digital input 23 = Digital output 14 = Digital output 25 = Supply voltage +6 = Supply voltage 0 VDC7 = Stabilised output voltage8 = Analog ground9 = Analog input 1+10 = Analog input 1 -11 = Analog input 2+12 = Analog input 2 -13 = Output solenoid driver 2 +14 = Output solenoid driver 2 -15 = Output solenoid driver 1 +16 = Output solenoid driver 1 –21 = HART (option) Analog input 3 +22 = HART (option) Analog input 3 -
AdditionalEnhanced amplifier
17 = Digital input 318 = Digital input 419 = Digital input 520 = Digital input 621 = Digital input 722 = Digital input 823 = Digital output 324 = Digital output 425 = Analog input 3 +26 = Analog input 3 -27 = Analog input 4 +28 = Analog input 4 -29 = Digital ground30 = Analog ground31 = Stabilised output voltage32 = Analog output
USB-interface, USB Type B X2
1 = VBUS2 = D -3 = D+4 = GND
The parameterisation cable is not included in the delivery(commercially available USB cable, plug type A to plug type B)
Device receptacle CANopen, J1939 (male) X4 (option)
1 = Reserved 6 = Reserved2 = CANLow 7 = CANHigh3 = CANGnd 8 = Reserved4 = Reserved 9 = Reserved5 = CANShield
The mating connector (plug female, DSUB, 9-pole) is not included in the delivery.
Device receptacle Profibus (female) X4 (option)
1 = Reserved 6 = VP2 = Reserved 7 = Reserved3 = RxD / TxD - P 8 = RxD / TxD - N4 = Reserved 9 = Reserved5 = DGND
The mating connector (plug male, DSUB, 9-pole) is not included in the delivery.
1 2 3 45 6 7 8
13 14 15 169 1011 12
ER
RO
RFU
NC
TIO
NS
UPP
LY
17 18 19 2021 22 23 24
FIE
LDB
US
X4
293031 32252627 28
USB
54321
9876
2
14
3
12345
6789
12345
6789
54321
9876
12345
6789
Enhanced amplifierwith HART
17 = Analog output +18 = Analog output -19 = Digital input 320 = Digital input 421 = Analog input 3 + HART22 = Analog input 3 - HART23 = Analog input 4 +24 = Analog input 4 -
Dimensions
Connector Wiring Diagram / Pin Assignment
Electro
nics & A
ccesories
110
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NPD2 Digital Amplifier Electronics
» For 1 proportional or switching solenoid» With cable outlet for free choice of the valve connection plug» Protection class IP 67» 1 analog input» 1 digital input
Technical Data
Description Norgren‘s NPD2 Amplifier with cable outlet allows for your choice of the connection plug such as DIN EN 175301-803/ISO 4400, AMP Junior Timer or Deutsch DT04-2P. Protection class IP67. The connection and solenoid cable are mounted fixed in the device. The voltage range enables the control of 12 VDC and 24VDC devices. The amplifier is also available mounted directly on the solenoid.
Function The electronics has a Pulse-Width-Modulated current output. The solenoid output can also be parameterised for switching solenoids. Configuration can be carried out directly on the device by means of push-buttons and display, or through Norgren‘s included parameterisation and diagnostics software.
Application Due to its water spray resistant connection, the amplifier is suitable for challenging environments. NPD2‘s easy connection enables assembly and commissioning with conventional tools. All settings can be carried out easily and quickly using its integrated buttons and display.
Designation: With cable outlet for free choice of the valve connection plug
Dimensions:See drawing page 2
Ambient Temperature:-40...+85 °C, -40...+185 °F
Installation:2 screws M3x20, tightening torque 0.1 Nm
Connection:
Protection Class:IP 67 acc. to EN 60 529
Supply Voltage: 8…32 V
Residual Ripple: < +/-5 %
Fuse: Low
No-load Current:Approx. 20 mA
Max. Current Consumption:No-load current + 2.5 A per solenoid
*Analog Input:1 input non-differentialVoltage / current (switchable by means of parameter)0...+/- 10V or 0/4...20mA
Dither:Frequency adjustable 4…500 HzFactory setting 80 HzLevel adjustable 0…400 mAFactory setting 180 mA
Resolution:10-bit
USB interface:Via digital inputRequires the Norgren USB adapter
Input Resistance:Voltage input »100 kΩ(Input current < 5 mA)Load for current input = 124 Ω
Stabilized Output Voltage:5 VDC Max. load 20 mA
Solenoid Current:Minimal current lmin: Adjustable 0…Imax mAFactory setting 150 mAMaximal current lmax: Adjustable Imin…2450mAFactory setting 700 mA
Temperature Drift:<1 % at ΔT = 40 °C
Digital Inputs:1 input high-active, no pull-up/downSwitching threshold high 6...32 VDCSwitching threshold low 0…1 VDCUsable as frequency input(frequency 5...5000 Hz) and as PWM input(automatic frequency recognition)
EMV:Immunity EN 61 000-6-2Emission EN 61 000-6-4
5 x 0.34 mm2,Exterior coating PVClength = 1.5 m or 7.5 m
2 x 0.34 mm2,Exterior coating PVClength = 0.5 m
Via connection«Digital input»requires the Norgren USB adapter NPD2
Connection Cable
Solenoid Cable
USB interface
» Interface: - analog - CANopen / J1939» Adjustable with pushbuttons and display directly on the device or via PC
111
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NPD2 Digital Amplifier Electronics
NP D2 A 3 0 1 D8 0 A 15Configurator
Block Diagram
Analog Interface CANopen Interface
Control Cubicle NP
Digital D2
Optional Fieldbus Without fieldbus A
Adjustable with PASO and manual operation 3
Adjustable with Basic Amplifier 0
Number of Solenoids 1-solenoid Version 1
Supply Voltage 8...32 VDC D8
10-bit resolution 0
Analog Input Voltage / current (not for fieldbus) A
Connection Cable Length 15 cm 15
Electro
nics & A
ccesories
112
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NPD2 Digital Amplifier Electronics
Dimensions4/3 way spool valve (spring centered)
Connector AssignmentConection cable (X1)
1 brown2 green3 white
4 yellow5 gray
1 brown
2 white1 = + VCC2 = Command value
3 = Dig Inp4 = Stab out
5 = GND1 = Solenoid +2 = Solenoid -
Accessories
USB-adapter NPD2Incl. USB-cable, type A-B, 1.8 m(for parameterrisation via PC)
Item No. N018271
Start-upInformation regarding installation and commissioning are contained in the information leaflet supplied with the amplifier electronics and in the operating instructions.Additional information can be found on our website: www.norgren.com
Free-of-charge download:• «NPD2» Parameterisation software• Operating instruction (*.pdf)
AdjustmentsThe NPD2 electronics have push-buttons and a 7 segment display which enable setting the most important parameters. In addition, the digital input can be used as a communication interface, through which, by means of Norgren’s included parameterisation software, the complete parameterisation and diagnostics can be carried out. For this, Norgren USB-NPD2 adapter is required. (not included in the delivery)Important: During the communication, the digital input cannot be used.
113
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NPD2 Digital Amplifier Electronics
Function Description
NPD2 Amplifier FunctionCommand Value ScalingThe command value can be applied as a voltage, current, digital, frequency or PWM signal. The scaling takes place via the parameter "Interface”. Furthermore, the command value can be monitored for a cable break. A dead band can also be set.
Fixed Command ValueThere is 1 fixed command value available, which can be selectedvia the digital input. This function has to be configurated beforein parameterization software.
Ramp GeneratorTwo linear ramps for up and down are available which can beadjusted separately.
Valve TypeAdjustment possibilities: switching solenoid or proportional solenoid.
Mode of Operation, Command value unipolar/bipolar (1-Sol)Dependent on a command value signal (voltage, current, digital, frequency or PWM), (CAN-bus, digital, frequency or PWM), the solenoid is driven (e.g. 0….10V correspond to 0 to 100% command value, 0 to +100% command value correspond to Imin….Imax solenoid driver), (e.g. 0….16383 CAN-commandcorrespond to 0….100% command value, 0….+100% commandvalue correspond to Imin….Imax solenoid driver)
Signal recordingFurthermore, the "NPD2“ amplifier electronics have a signalrecording function. This, by means of Norgren’s included parameterization software, enables the recording of various system signals, such as command value, solenoid current, etc., which can be represented on a common time axis.
Solenoid driverA Pulse-Width-Modulated current output is available. A dithersignal is superimposed, whereby the dither frequency and thedither level are separately adjustable. The minimum (Imin) andmaximum (Imax) current can be adjusted. The solenoid outputcan also be configurated as switching solenoid output. In thiscase, a power reduction can be adjusted. Optimization of characteristic curve An adjustable characteristic curve "Command value input – solenoid current output“ enables an optimised (e.g. linearised) characteristic of the hydraulic system.
Channel enablingAs per factory setting, devices with analog interface is enabled ("on“) CANbus interface devices be enabled via CANbus. This "enable channel“ can be set to "on“, "off“ or "external“ (digital input) via Norgren’s included parameterization software or via menu item.
Important!Digital input: If deenergised, not wired, the state is not definedAnalog input: If deenergised, the voltage input will read 1.11 V constantly
Electro
nics & A
ccesories
114
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
NPD2 Digital Amplifier Electronics
NPD2 Amplifier
115
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
» Robust construction for mobile applications
» For 4 or 8 proportional- or switching solenoids
» Plug-in connection suitable for mobile applications
» Protection class IP67
Technical DataExecution:Housing made of plasticConnections:Screw terminals-max. cable cross-section 2.5 mm2Weight: 1.11 lb (0.50 kg)Dimensions:153 x 57 x 147 (see dimensions)Ambient Temperature:-40...+185 °F (-40…+85 °C)Installation:On metallic surface, screwed onMating Connector:Plug (female) type SHS, 30-poles (not incl. in delivery)Plug (female) type SHS, 18-poles (for NMD2 «Enhanced» only, not incl. in delivery)Environmental Compatability:The material limit values from the RoHS-directive (2002/95/EC) and the ELV «end-of life vehicles directive» (2000/53/EC) are complied with.Protection Class:IP67 acc. to DIN / EN 60 529Supply Voltage:8...32 VDC (for logic part)Residual Ripple:<10 %Fuse:Slow-blowNo-load Current:Approx. 55 mAMax. Current Consumption:No-load current + 2 A per solenoidAnalog Inputs: • Voltage 0…+5 V / 0…+10 V / -10…+10 V• Current 4…20 mA / 0…+20 mA• Resolution Basic: Analogue inputs 1 and 2: 10-Bit resolutionEnhanced: Analogue inputs 1 to 4:16 bit resolution• Input resistance Voltage input » 18 k! Load for current input = 250 !
Stabilised Output Voltage:5 VDC Max. load 50 mASolenoid current:• Minimal current Imin Adjustable 0…950 mAFactory setting 150 mA• Maximal current Imax Adjustable Imin…2 A Factory setting 700 mA• Accumulated current limitation 10 AThe number of solenoids simultaneously supplied with current and their maximum current are dependent on the ambient temperature. Further information can be found in the operating instructions.Analog Output:Enhanced amplifier:Voltage output ± 10 VDCMax. output current ± 3 mAEnhanced amplifier with HART:Current output 0…20 mAMax. output voltage 12 VDCResolution:10-bit (analog inputs 1 and 2)16-bit (analog inputs 3 and 4)Input Resistance:Voltage input »18 kΩLoad for current input = 250 ΩStabilised Output Voltage:10 VDC (with 24 VDC)8 VDC (with 12 VDC)Max. load 30 mACANopen® Interface (optional): Two-wire line acc. to ISO 11898 differential signal transmissionBustopology:LineVoltage Separation:CANopen® to NMD2 500 VDCDither: Frequency adjustable 20…500 HzFactory-preset 100 HzAmplitude adjustable 0…400 mAFactory-preset 100 mATemperature Drift: <1 % at ΔT = 40 °C
Digital inputs:Switching threshold high 6…32 VDCSwitching threshold low 0…1 VDCUtilisable as frequency input (frequencies 0…5 kHz) and as PWM-input (automatic frequency identification)Digital Outputs: • High-Side-Switch• Maximum load 500 mA per output• Ramps adjustable 0…500 s• Serial interface USB (receptacle
type B) to set parameters with «PASO»
LED:Green: – is lit, when the NMD2 – electronics are ready for operation.– blinks twice, if the supply voltage is too low for the solenoid outputs.Red: – is lit, when an error has occurred The cause for the error can be indentified by means of the «PASO» - software.EMV:• Immunity EN 61 000-6-2• Emission EN 61 000-6-4• Road vehicles ISO 7637-2 and RL
2004/104/EC• Vibration / shock• Oscillation IEC 60 068-2-6• Single shock IEC 60 068-2-27• Continuous shock IEC 60 068-2-29
» Adjustable via PC» CANopen®-Connection » Available as amplifier or controller
Electro
nics & A
ccesories
116
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
Configurator
The parameterization cable is not included in the delivery (commercially available USB cable, plug type A to plug type B). The amplifier module can be configured by means of the parameterization software through the USB-interface. In addition, the parameterization software makes a data analysis possible. Optionally the amplifier module is equipped with a manual operation, which enables the setting of the most important parameters by means of rotary selector switch and push-buttons and therefore makes a commissioning of the amplifier module possible without a PC.
Description Digital amplifi er electronics, with four or eight solenoid outputs. They are characterised by a robust and compact construction. The extensivesupply voltage range enables the driving of 12VDC- and 24VDC- devices. The parameterisation takes place through the menu controlled through Norgren‘s parameterisation and diagnostics software (USB-interface). The electronics are available as an amplifier and as a controller function with optional CANinterface (according to CANopen® DSP-408).
Function The electronics have four, resp., eight pulse width modulated current outputs with superimposed dither signal. The solenoid outputs can also be parameterised for black /white solenoids. The two, resp. four analogue- and digital inputs as well as the two digital outputs are individually programmable. With the device, control- and closed-circuit control tasks can very easily be solved. The CAN-connection enables the reading-in of command value- and feedback value signals as well as the parameterisation directly through the fieldbus.
Application As snap-on module, the amplifier module is mainly utilized in the industrial field. The module can be mounted on dome-rails. The connection with terminal screws enables commissioning without special tools in a short time. The amplifier module is particularly suitable for applications with additional functions such as ramps, fixed command values, etc. Customer specific requirements can be implemented in a simple manner.
NM D2 A 3 0 4 D8 A-3Mobile NM
Digital D2
Optional Fieldbus Without fieldbus A
Adjustable with PASO Software 3
Adjustable with Basic Amplifier 0
Number of Solenoids 4-solenoid Version 4
Supply Voltage 8...32 VDC D8
Amplifier Basic Amplifier without HART Analog input 1 and 2: 10 Bit Resolution A
InputsBasic Amplifer
Analog input 1 and 2 both current Analog input 3 always current (with HART only)
3
117
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
Command value scaling The command value can be applied as a voltage -, current -, digital -, frequency - or PWM-signal. For each command value the input utilized can be selected. The scaling takes place through the parameters «Interface» and «Reference». Furthermore each command value can be monitored for cable break (excepting the voltage - and digital signal). For each command value a dead band can be set.
Fixed command valuesThere are 7 fixed command values available, which can be selected through 3 digital inputs.
Command value generator Per solenoid output, two linear ramps separately settable for Up and Down are available.
Valve type Here the operating mode is set, when in open-loop controller mode. In addition it can be selected, whether proportional - or switching solenoids are to be driven.
Operating mode command value unipolar (1-solenoid)» The solenoid is driven in dependence of a unipolar command value signal (voltage, current, frequency or PWM) (e.g., 0...10V correspond to 0...100 % command value, 0...100 % command value correspond to Imin...Imax solenoid driver 1).
Operating mode command value unipolar (2-solenoids)» Depending on the signal level (voltage, current, frequency or PWM), one of the two solenoids is driven in dependence of a unipolar command value signal. The switching point between the two solenoids, as standard, is at the centre of the values range of the command value signal (e.g., 0...10V correspond to -100...+100 % command value, -100...0 % command value correspond to Imin...Imax solenoid driver 2, 0...+100 % command value correspond to Imin...Imax solenoid driver 1).
Operating mode command value bipolar (2-solenoids)» In dependence of a bipolar command value signal (voltage), according to the signal level, one of the two solenoids is driven. The changeover point between the two solenoids as standard is at 0V (e.g., -10...+10V correspond to -100...+100 % command value, -100...0 % command value correspond to Imin...Imax solenoid driver 2, 0...+100 % command value correspond to Imin...Imax solenoid driver 1).
Operating mode command value unipolar (2-solenoids with DigIn)» In dependence of a unipolar command signal (voltage, current, frequency or PWM) the solenoid is driven by the solenoid driver 1, if the selected digital input is «not activated», resp. the solenoid is driven by the solenoid driver 2, if the selected digital input is «activated» (e.g., 0...10V correspond to 0...100 % command value, 0...100 % command value correspond to Imin...Imax solenoid driver 1 or 2).
Solenoid driversFour (in case of the basic version) or eight (in case of the enhanced version) pulse width modulated current outputs are available. A dither signal is superimposed on the output, whereby the dither frequency and the dither level are separately adjustable. For each output the minimum (Imin) and the maximum (Imax) current can be separately set. The solenoid outputs are also configurable as switching outputs. In doing so,a power reduction can be separately set for each output.
Design The mobile electronics can be configured by means of the parameterization software through the USB-interface. In addition, the parameterisation software makes a data analysis possible, with integrated graphic signal recording. The software is supported by Windows 2000, Windows XP, Windows Vista and Windows 7.
Electro
nics & A
ccesories
118
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
Block Diagram Basic Amplifier
119
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
Dimensions
Assembly
Parameterisation software Refer to commissioning
Connection-Set for NMD2
«Basic» Item No. EN997.72100
- 1 pce mating connector 30-poles
- 50 pce crimp terminals
- 30 pce cavity filler plugs
Connection-Set for NMD2
«Enhanced»
Item No. EN997.72101
- 1 pce mating connector 30-poles
- 1 pce mating connector 18-poles
- 80 pce crimp terminals
- 50 pce cavity filler plugs
Mating connector Plug (female) type SHS 30-poles
Cinch Item No. EN0115830029
Mating connector Plug (female) type SHS 18-poles
Cinch Item No. EN01158180213
Crimp terminal 0.8–1.0 mm2
Cinch Item No. EN0054200873
Cavity filler plug Cinch Item No. EN00158000111
Tool (to open mating connector) Cinch Item No. EN11959116218
Item No. T909.08395
Accessories
Electro
nics & A
ccesories
120
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
Connector Wiring Diagram / Pin Assignment
Start-upInformation regarding installation and commissioning are contained in the information leaflet supplied with the amplifier electronics and in the operating instructions.Additional information can be found on our website: www.norgren.com
Free-of-charge download:• «PASO-NMD2» Parameterisation software• Operating instruction (*.pdf)
121
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
K0930_e.ai
K0932_e.ai
Function
NMD2 AmplifierCommand Value Scaling:The command value can be applied as a voltage -, current -, digital -, frequency - or PWM-signal. For each command value the input utilized can be selected. The scaling takes place through the parameters «Interface» and «Reference». Furthermore each command value can be monitored for cable break (excepting the voltage - and digital signal). For each command value a dead band can be set.
Fixed Command Values:There are 7 fixed command values available, which can be selected through 3 digital inputs.
Command Value Generator:Per solenoid output, two linear ramps separately settable for Up and Down are available.
Valve Type:Here the operating mode is set, when in open-loop controller mode. In addition it can be selected, whether proportional - or switching solenoids are to be driven.
Operating Mode Command Value Unipolar (1-solenoid):The solenoid is driven in dependence of a unipolar command value signal (voltage, current, frequency or PWM) (e.g., 0...10V correspond to 0...100 % command value, 0...100 % command value correspond to Imin...Imax solenoid driver 1).
K0930_e.ai
K0932_e.ai
Operating Mode Command Value Unipolar (2-solenoids):Depending on the signal level (voltage, current, frequency or PWM), one of the two solenoids is driven in dependence of a unipolar commandvalue signal. The switching point between the two solenoids, as standard, is at the centre of the values range of the command value signal (e.g., 0...10V correspond to -100...+100 % command value, -100...0 % command value correspond to Imin...Imax solenoid driver 2, 0...+100 % command value correspond to Imin...Imax solenoid driver 1).
Operating Mode Command Value Bipolar (2-solenoids):In dependence of a bipolar command value signal (voltage), according to the signal level, one of the two solenoids is driven. The changeoverpoint between the two solenoids as standard is at 0V (e.g., -10...+10V correspond to -100...+100 % command value, -100...0 % command valuecorrespond to Imin...Imax solenoid driver 2, 0...+100 % command value correspond to Imin...Imax solenoid driver 1).
K0930_e.ai
K0932_e.ai
Design The mobile electronics can be configured by means of the parameterization software through the USB-interface. In addition, the parameterisation software makes a data analysis possible, with integrated graphic signal recording. The software is supported by Windows 2000, Windows XP, Windows Vista and Windows 7.
Description of NMD2 amplifer electronics
Electro
nics & A
ccesories
122
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
Connection Example Basic AmplifierAmplifier module: NMD2 Basic (all analogue inputs voltage)
N
123
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
Operating Mode Command Value Unipolar (2-solenoids with DigIn):In dependence of a unipolar command signal (voltage, current, frequency or PWM) the solenoid is driven by the solenoid driver 1, if the selected digital input is «not activated», resp. the solenoid is driven by the solenoid driver 2, if the selected digital input is «activated» (e.g., 0...10V correspond to 0...100 % command value, 0...100 % command value correspond to Imin...Imax solenoid driver 1 or 2).
Solenoid Drivers:Four (in case of the basic version) or eight (in case of the enhancedversion) pulse width modulated current outputs are available. A dithersignal is superimposed on the output, whereby the dither frequency andthe dither level are separately adjustable. For each output the minimum(Imin) and the maximum (Imax) current can be separately set. The solenoid outputs are also configurable as switching outputs. In doing so,a power reduction can be separately set for each output.
K0933_e.aiK0931_e.ai
Connection Example Basic Amplifier
K0933_e.ai
K0931_e.ai
N
Amplifier module: NMD2 Basic (all analogue inputs voltage)
Electro
nics & A
ccesories
124
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
Function
NMD2 AmplifierCommand Value Scaling:The command value can be applied as a voltage -, current -, digital -, frequency - or PWM-signal. For each command value the input utilised can be selected. The scaling takes place through the parameters «Interface» and «Reference». Furthermore each command value can be monitored for cable break (excepting the voltage - and digital signal). In the version with CAN-connection, the command value can also be digitally transmitted.Fixed Command Values:There are 7 fixed command values available, which can be selected through 3 digital inputs.Command Value Generator:In the open-loop controller modes, two linear ramps separately settable for Up and Down are available per solenoid output.In the closed-loop controller modes, a positive and a negative travelling speed are available.Valve Type:Here the operating mode is set, when in open-loop controller mode. In addition it can be selected, whether proportional - or switching solenoids are to be driven.Feedback value scaling The solenoid is driven in dependence of a unipolar command value signal (voltage, current, frequency or PWM) (e.g., 0...10V correspond to 0...100 % command value, 0...100 % command value correspond to Imin...Imax solenoid driver 1).Windows Available are a target -, contouring error - and solenoid-off window. Ineach window the threshold and the delay time can be adjusted.Controller Two (for the Basic version) or four (for the Enhanced version) controllercircuits are available. The following controller modes can be selected:
Controller mode 3 «Pressure / volume fl ow valve control»Driving of a pressure relief -, pressure control -, throttle - or fl ow controlvalve in the open control circuit (without feedback value return). Thenumber of solenoids that are driven is dependent on the selectedoperating mode.Controller mode 4 «Pressure / volume fl ow valve control (1-solenoid)»Driving of a 1-solenoid pressure relief -, pressure control -, throttle - orfl ow control valve in the closed control circuit (with feedback valuereturn). With it, only one solenoid can be driven (corresponds to thesolenoid driver 1).
Operating Mode Command Value Bipolar (2-solenoids):In dependence of a bipolar command value signal (voltage), according to the signal level, one of the two solenoids is driven. The changeoverpoint between the two solenoids as standard is at 0V (e.g., -10...+10V correspond to -100...+100 % command value, -100...0 % command valuecorrespond to Imin...Imax solenoid driver 2, 0...+100 % command value correspond to Imin...Imax solenoid driver 1).
N
N
Design
The mobile electronics can be configured by means of the parameterization software through the USB-interface. In addition, the parameterisation software makes a data analysis possible, with integrated graphic signal recording. The software is supported by Windows 2000, Windows XP, Windows Vista and Windows 7.
Description of NMD2 amplifer electronics
125
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Digital Amplifier Controller NMD2
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Controller Mode 6 «Axis Position Controlled»Driving of a directional control valve in the open control circuit (without feedback value return). The number of solenoids that are driven is dependent on the selected operating mode.
Controller Mode 9 «Axis Position Controlled»Driving of a 2-solenoid directional control valve in the closed control circuit (with feedback value return). With it, two solenoids can be driven.
Controller Mode 9 «Axis Position Controlled»Driving of a 2-solenoid directional control valve in the closed control circuit (with feedback value return). With it, two solenoids can be driven.
Controller mode -6 «2-Point controller (1-solenoid)»Driving of a 1-solenoid valve with switching solenoid in the closed control circuit (with feedback value return). With it, only one solenoid can be driven (corresponds to the solenoid driver 1).
Controller mode -7 «2-Point controller (2-solenoids)»Driving of a 2-solenoid valve with switching solenoid, resp. of two 1-solenoid valves with switching solenoid in the closed control circuit (with feedback value return). With it, two solenoids can be driven.
Controller mode -8 «3-Point controller (2-solenoids)»Driving of a 2-solenoid valve with switching solenoid, resp., of two 1-solenoid valves with switching solenoid in the closed control circuit (with feedback value return). With it, two solenoids can be driven.
Valve typeHere the operating mode is set when in open-loop controller mode. In addition it can be selected, whether proportional - or switching solenoids are to be driven. A detailed description of the operating modes can be found in the section «Description of the NMD2-amplifier electronics», page 6.
Solenoid driversFour (in the basic version) or eight (in the enhanced version) pulse width modulated current outputs are available. A dither signal is superimposed on the output, whereby the dither frequency and the dither level areseparately adjustable. For each output the minimum (Imin) and the maximum (Imax) current can be separately set. The solenoid outputs are also confi gurable as switching outputs. In doing so, for each output a power reduction can be separately set.
Electro
nics & A
ccesories
126
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Selection of filter / recommendationIn the following table, the degrees of contamination (extract) in accordance with ISO 4406:1999 with number of particles/100 ml, as well as hydraulicvalve groups with the filter fineness recommended for them are indicated.
Hydraulic Fluids and Filtration
Contamination in hydraulic unitsOne differentiates between the following kinds of contamination:
Initial contamination:This contamination takes place during the erection and commissioning of the hydraulic units.(Dust, swarf, rust, hammer scale, packaging residues, etc.)
Contamination by new oil:The oil supplied by the oil supplier is often contaminated, therefore the oil definitely must be filtered before filling it into the unit.
Contamination during operation:Entry of dirt into the hydraulic tank due to insufficient ventilation, piston rod seals, etc.
Filter / degree of contaminationIn the Norgren product documentation, degrees of contamination and recommended filters are indicated as follows:Example: Maximum admissible degree of contamination ISO 4406:1999, class 18/16/13
Recommended filter with retention rate ß 6…10 ≥ 75
Contamination classesThe contaminations classes indicate how many particles of a certain size are contained in 100 ml of hydraulc fluid. Usually control- and proportionalvalves are the components most sensitive to contamination in the hydraulic unit. Therefore they determine the overall degree of contamination ofthe hydraulic oil. At the moment, 5 classification systems are available (ISO 4406:1999, resp. NAS 1638 , SAE, Mil. std. 1246A). In the Norgrenproduct documentation the maximum admissible degrees of contamination are indicated in classes in accordance with ISO 4406:1999.
Retention rate / beta - valueThe retention rate of a filter element is the measure for the separation capacity of the filter for defined particle sizes. It is defined by the beta-value(ß x) The ß x value is the ratio of all particles » x μm before the filter, to the particles » x μm after the filter.
Example: Filter element with retention rate ß 10 ≥ 75
Contamination level before the filter
Filter with retention rate Contamination level afterthe filter
Filtering
Wandfluh AG Tel. +41 33 672 72 72 E-mail: [email protected] Illustrations not obligatory Data sheet no.Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.0-50E 1/1CH-3714 Frutigen Edition 17 01
CONTAMINATION IN HYDRAULIC UNITSOne differentiates between the following kinds of contamination:Initial contamination:This contamination takes place during the erection and commissioning of the hydraulic units. (Dust, swarf, rust, hammer scale, packaging residues, etc.)
Contamination by new oil:The oil supplied by the oil supplier is often contaminated, therefore the oil definitely must be filtered before filling it into the unit.
Contamination during operation:Entry of dirt into the hydraulic tank due to insufficient ventilation, piston rod seals, etc.
FILTER / DEGREE OF CONTAMINATIONIn the Wandfluh product documentation, degrees of contamination and recommended filters are indicated as follows:Example:
Maximum admissible degree of contamination ISO 4406:1999, class 18/16/13Recommended filter with retention rate ß 6…10 ≥ 75
CONTAMINATION CLASSESThe contaminations classes indicate how many particles of a certain size are contained in 100 ml of hydraulc fluid. Usually control- and proportional valves are the components most sensitive to contamination in the hydraulic unit. Therefore they determine the overall degree of contamination of the hydraulic oil. At the moment, 5 classification systems are available (ISO 4406:1999, resp. NAS 1638 , SAE, Mil. std. 1246A). In the Wandfluh product documentation the maximum admissible degrees of contamination are indicated in classes in accordance with ISO 4406:1999.
RETENTION RATE / BETA - VALUEThe retention rate of a filter element is the measure for the separation capacity of the filter for defined particle sizes. It is defined by the beta-value (ß x) The ß x value is the ratio of all particles > x µm before the filter, to the particles > x µm after the filter.
Example: Filter element with retention rate ß 10 ≥ 75
Filter with retention rateContamination levelbefore the filter
Contamination level after the filter
1'000'000particles> 10 µm
13'333particles> 10 µm
In the Wandfluh product documentation, the retention rate is indicated as ß x ≥ 75. Further customary retention rates are: ß x ≥ 2, 20 und 200
SELECTION OF FILTER / RECOMMENDATIONIn the following table, the degrees of contamination (extract) in accordance with ISO 4406:1999 with number of particles/100 ml, as well as hydraulic valve groups with the filter fineness recommended for them are indicated.
over 15 µm
Filterß 10 ≥ 75
Contaminationclasses
Number of particles per 100 ml
over 5 µm
16/14/11 > 8000…16000 > 1000…2000 ß 3…6
18/16/13 > 32000…64000 > 4000…8000 ß 6…10
20/18/14 > 130000…250000 > 8000…16000 ß 10…16
21/19/15 > 250000…500000 > 16000…32000 ß 16…25
Con
trol v
alve
s
Pro
p. v
alve
s in
gen
eral
Sof
t shi
ftva
lves
Recommendedfilter finenessß x ≥ 75(x = µm)
Pro
p. v
alve
sin
con
trol
syst
ems
Valv
es w
ithco
ntro
l pl
unge
r
Pop
pet v
alve
s
Valv
es in
ge
nera
l>
160
bar
Valv
es in
ge
nera
l<
160
bar
Pressure filterrequired
Pressure filterrecomended return line filter
Filtering
Wandfluh AG Tel. +41 33 672 72 72 E-mail: [email protected] Illustrations not obligatory Data sheet no.Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.0-50E 1/1CH-3714 Frutigen Edition 17 01
CONTAMINATION IN HYDRAULIC UNITSOne differentiates between the following kinds of contamination:Initial contamination:This contamination takes place during the erection and commissioning of the hydraulic units. (Dust, swarf, rust, hammer scale, packaging residues, etc.)
Contamination by new oil:The oil supplied by the oil supplier is often contaminated, therefore the oil definitely must be filtered before filling it into the unit.
Contamination during operation:Entry of dirt into the hydraulic tank due to insufficient ventilation, piston rod seals, etc.
FILTER / DEGREE OF CONTAMINATIONIn the Wandfluh product documentation, degrees of contamination and recommended filters are indicated as follows:Example:
Maximum admissible degree of contamination ISO 4406:1999, class 18/16/13Recommended filter with retention rate ß 6…10 ≥ 75
CONTAMINATION CLASSESThe contaminations classes indicate how many particles of a certain size are contained in 100 ml of hydraulc fluid. Usually control- and proportional valves are the components most sensitive to contamination in the hydraulic unit. Therefore they determine the overall degree of contamination of the hydraulic oil. At the moment, 5 classification systems are available (ISO 4406:1999, resp. NAS 1638 , SAE, Mil. std. 1246A). In the Wandfluh product documentation the maximum admissible degrees of contamination are indicated in classes in accordance with ISO 4406:1999.
RETENTION RATE / BETA - VALUEThe retention rate of a filter element is the measure for the separation capacity of the filter for defined particle sizes. It is defined by the beta-value (ß x) The ß x value is the ratio of all particles > x µm before the filter, to the particles > x µm after the filter.
Example: Filter element with retention rate ß 10 ≥ 75
Filter with retention rateContamination levelbefore the filter
Contamination level after the filter
1'000'000particles> 10 µm
13'333particles> 10 µm
In the Wandfluh product documentation, the retention rate is indicated as ß x ≥ 75. Further customary retention rates are: ß x ≥ 2, 20 und 200
SELECTION OF FILTER / RECOMMENDATIONIn the following table, the degrees of contamination (extract) in accordance with ISO 4406:1999 with number of particles/100 ml, as well as hydraulic valve groups with the filter fineness recommended for them are indicated.
over 15 µm
Filterß 10 ≥ 75
Contaminationclasses
Number of particles per 100 ml
over 5 µm
16/14/11 > 8000…16000 > 1000…2000 ß 3…6
18/16/13 > 32000…64000 > 4000…8000 ß 6…10
20/18/14 > 130000…250000 > 8000…16000 ß 10…16
21/19/15 > 250000…500000 > 16000…32000 ß 16…25
Con
trol v
alve
s
Pro
p. v
alve
s in
gen
eral
Sof
t shi
ftva
lves
Recommendedfilter finenessß x ≥ 75(x = µm)
Pro
p. v
alve
sin
con
trol
syst
ems
Valv
es w
ithco
ntro
l pl
unge
r
Pop
pet v
alve
s
Valv
es in
ge
nera
l>
160
bar
Valv
es in
ge
nera
l<
160
bar
Pressure filterrequired
Pressure filterrecomended return line filter
In the Norgren product documentation, the retention rate is indicated as ß x ≥ 75.Further customary retention rates are: ß x ≥ 2, 20 und 200
127
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Tool Article Description of Contents Component #
Ecoline 2-way M18 x1.5 T908.0839 Form drill Form reamer
Form tool set 2-way M18 x 1.5 T908.0839
Form drill Form reamerTap
T901.0830T902.0830T906.0830
Cavity Tools
Valve Family
NSDSM18BA
NSDSM18AB
Application
Cartridge Cavity ISO 7789-18-01-0-98Cavities
:epyt egdirtraC :rebmun teehs ataD Data sheet number:
Tel. +41 33 672 72 72 E-mail: Illustrations not obligatory Data sheet no.Postfach Fax +41 33 672 72 12 Internet: www Data subject to change 2.13-1002E 1/1 CH-3714 Frutigen Edition 19 40
Cavity toolsDenomination: Article number: Content: Article number:
Cartridge cavity ISO 7789–18–01–0–98
Gen
eral
tole
ranc
esIS
O 2
768
Surface textureEdges according to ISO 13715
mmHHH
N8+0.4
±1 ±0.5 ±0.2
±0.3 ±0.2 ±0.1±0.1>30-120>6-30>3-6>0,5-3
Extract general tolerances ISO-2768-1
Radiuses, chamfer height
Linear dim.Nominal dim.-0.1
-0.3
Length dimensions, curves, chamfers AnglesStraightness, flatness Perpendicularity, symmetryRadial runout, axial runout Envelope condition acc. to ISO 14405
2-way-cavity forgeneral function(without pressure relief)
- PG - Migration - Default - 11.04.11/00:04:10
Ecoline 2-way M18 x 1,5 983.0809 Form drillForm reamer
Tool kit 2-way M18 x 1,5 983.0800 llird mroF 983.0100 remaer mroF 983.0200
Tap 983.0600
1.11-2050 DNIPM18-... 2.4-5121.11-2052 DR.PM18-... 2.4-6101.11-2054 QA.PM18-... 2.5-5101.11-2080 D.PPM18-... 2.6-510
ApplicationCartridge type: NSDSPM18-... NSDYPM18-... NSDZPM18-... NSVSPM18-... DN.PM18-... 2.4-510
Electro
nics & A
ccesories
128
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
3-way Cavity M18 x 1.5
Tool Article Description of Contents Component #
Form tool set 3-way Cavity M18 T908.0835
Form drill Form reamerTap
T901.0835T902.0835T983.0600
Cavity ToolsValve Family
NSDSM18FG
Application
129
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Valve Family
NSDSM18FG
Valve Family
NSDSM22BA
NSDSM22AB
Application Tool Article Description of Contents Component #
Form tool set 2-way Cavity M22 T908.0834
Form drill Form reamerTap
T901.0834T902.0834T906.0831
Cavity Tools
Cartridge Cavity ISO 7789-22-01-0-98
Cavity toolsDenomination: Article number: Content: Article number:
Application :epyt egdirtraC :epyt egdirtraC :rebmun teehs ataD Data sheet number:
Tel. +41 33 672 72 72 E-mail: Illustrations not obligatory Data sheet no.Postfach Fax +41 33 672 72 12 Internet: Data subject to change 2.13-1008E 1/1 CH-3714 Frutigen Edition 19 33
Cavities
Cartridge cavity ISO 7789–22–01–0–98
34 min.
M22x1.5
R0.1...0.2
0.3
R0.1...0.2
45° ±5°
30°
-0°
2°
18.5 max.
19 H8 + 0.0330 /38.5 tief min.
23.8 + 0.10 15° ±1°
0
2.4 + 0.40
15.5 min.
28 + 0.40
29.3 + 0.40
0
17 min.
27.5 max.
39 min. 40
+ 20
1
2
1
Ra 1.6
Ra 1.6
0.1 B
0.05 A
B
A
Allg
emei
n-to
lera
nzen
ISO
276
8
M 2:1
Dokument darf ohne schriftliche Einwilligung weder kopiert,verwertet noch an Dritte weitergegeben werden.Zuwiderhandlung ist strafbar und wird gerichtlich verfolgt.
Material: Material <nicht festgelegt>
Blatt 1 von 1
Revision
Gewicht
Gezeichnet
FreigegebenGeprüft
29.09.201629.11.2017
BEH
29.11.2017BRBR
Datum Name Änderungsbeschrieb
IND07.08.2017 Toleranz bei Ø23.8 auf +0.1/0 korrigiert04
Ersetzt durch:Ersatz für: 3-395.4 Rev.02Dok.-Nr.
Art.-Nr.
Rev. Änderungsnr.
Oberflächenbeschaffenheit
Serie freigegeben
Längenmasse, Rundungen,FasenWinkelGeradheit, EbenheitRechtwinkligkeit, SymmetrieRundlauf,PlanlaufHüllbedingung nach ISO 14405
Kanten nach ISO 13715
2-Wege Allgemeine FunktionSenkung ISO 7789-22-01-0-98
2 316020\eguezkreW_essülhcsnA_01\eihcrareihlekitrA\hulfdnaW_00\:C
A4
04
mmHHH
0.000 kg
3-395.4
0206132
Ra 3.2
03 BEH Neu in SolidWorks 29.09.2106
+0.4
±1 ±0.5 ±0.2
±0.3 ±0.2 ±0.1±0.1>30-120>6-30>3-6>0,5-3
Auszug Allgemeintoleranzen ISO-2768-1
Radien, Fasenhöhe
LängenmasseNennmass
Format
-0.1-0.3
E
Gen
eral
tole
ranc
esIS
O 2
768
Surface texture Length dimensions, curves, chamfersAnglesStraightness, flatnessPerpendicularity, symmetryRadial runout, axial runout
Edges according to ISO 13715
mmHHH
+0.4
±1 ±0.5 ±0.2
±0.3 ±0.2 ±0.1±0.1>30-120>6-30>3-6>0,5-3
Extract general tolerances ISO-2768-1
Radiuses, chamfer height
Linear dim.Nominal dim.-0.1
-0.3
Envelope condition acc. to ISO 14405
Ra 3.2
2-way-cavity forgeneral function(without pressure relief)
QZ.PM22-… 2.5-535D.PPM22-… 2.6-531 D.BPM22-… 2.6-535DNPPM22-../ME 2.6-541QNPPM22-… 2.6- 631QNPPM22-../ME 2.6-633QNBPM22-… 2.6-634
2-way M22 x 1,5 983.0804 llird mroF 983.0104 remaer mroF 983.0204
Tap 983.0601
SDSPM22-BA/AB-… 1.11-2060 SDSPM22-BA/AB-… 1.11-2061SDYPM22-BA/AB-… 1.11-2064 SVSPM22-BC/CB-… 1.11-2082SVYPM22-… 1.11-2084 MS.PM22 2.2-532
...-22MPIND 2.4-532QRSPM22-... 2.5-530
Electro
nics & A
ccesories
130
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Valve Family
NSDSM22FG
Application Tool Article Description of Contents Component #
Form tool set 3-way Cavity M22 T908.0832
Form drill Form reamerTap
T901.0832T902.0832T906.0831
Cavity Tools
Cartridge Cavity ISO 7789-22-04-0-98
33--wwaayy--ccaavviittyyggeenneerraall ffuunnccttiioonn(without pressure relief)
131
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Valve Family
NSDSM22FG
2-way Cavity 1 5/16-12 UN-2B
Valve Family
NQPU16N
Application
2-way-cavity
10
Electro
nics & A
ccesories
132
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Valve Family
NQDPU16D
Application
3-way-cavity
3-way Cavity 1 5/16-12 UN-2B
133
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Valve Family
NMPM16D
Application
3-way Cavity M16 x 1.5
R0.1...0.2
R0.1...0.2
R0.1...0.2
3-way cavity
Valve Family
NQDPU16D
Electro
nics & A
ccesories
134
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Valve Family
NWVPFM33
Application
4-way Cavity M33 x 2
4-way cavity with 2 pilot pipes
135
Electro
nics & A
ccesories
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Valve Family
NWVPFM42
Application
4-way Cavity M42 x 2
4-way cavity with 2 pilot pipes
Valve Family
NWVPFM33
Electro
nics & A
ccesories
136
7
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021-9619a) © 2021 Norgren
Factory Automation
Valve Family
NWDPPU10
Application
4-way Cavity 7/8“-14 UNF-2B
ApplicationCartridge type: Data sheet number: Cartridge type: Data sheet number:
Wandfluh AG Tel. +41 33 672 72 72 E-mail: [email protected] Illustrations not obligatory Data sheet no.Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 2.13-1057E 1/1 CH-3714 Frutigen Edition 15 46
Cavities
Cartridge cavity
4-way-cavity
WDPPU10 1.10-2720
30° +2°0°
Radien können auchals Fasen gefertigtwerden
X (5 : 1)
R0.1-0.2
0.8
max
.
R0.1
30 min.
14.27 max.
15.9 ±0.025
6.75
max
.
20.6 + 0.050
17.5 ±0.025
R1.6
R1.6
R1.6
19.08 ±0.025
45°
7/8"-14 UNF-2B
15°
0 2.75 ±0.2
38.1
54
63.5 min.
24 ±0.05
15.9
22.1
0
18.26
49.78
33.78
X
1
2
4
3X
XRa 1.6
Ra 1.6
ø0.01 B
0.025 A0.05 B
A
B
Ra 1.6
0.01 B
30° +
2°0°
Radii can also be made as chamfers
X (5 : 1)
R0.1-0.2
0.8
max
.
R0.1
30 min.
14.27 max.
15.9 ±0.025
6.75
max
.
20.6 +0.05
0
17.5 ±0.025
R1.6
R1.6
R1.6
19.08 ±0.025
45°
7/8"-14 UNF-2B
15°
0 2.75 ±0.2
38.1
54
63.5 min.
24 ±0.05
15.9
22.1
0
18.26
49.78
33.78
X
1
2
4
3X
XRa 1.6
Ra 1.6
ø0.01 B
0.025 A0.05 B
A
B
Ra 1.6
0.01 B
Norgren, Buschjost, FAS, Herion, Kloehn, Maxseal and Thompson Valves are registered trademarks of Norgren companies.Due to our policy of continuous development, Norgren reserve the right to change specifications without prior notice.z9774CT en/05/21Selected Images used under license from Shutterstock.com
For further information, scan this QR code or visit
www.norgren.com
2
4
5
6
3
1Direct Operated Spool Valve32 NWDPFA3 NG3-Mini 36 NWDPFA4 NG4-Mini 39 NWDPFA6 NG6 43 NWDPF65A10 NG10
Pilot Operated Spool Valve47 NVPF90A10 NG10
Manifold Mount05 NB3S NG3-Mini08 NB4S NG4-Mini 12 NA6S NG6 16 NA6S43 4/3 -way NG6 19 NA10M NG10
Cartridge23 NSDSM18 M18 X1.5 ISO 778927 NSDSM22 M22 X1.5 ISO 7789
Cartridge70 NMPM16D M16 x 1.5
Direct Operated Spool Valve52 NWDPU10 - 7/8“-14 UNFPilot Operated Spool Valve56 NWVPM3359 NWVPM42
Cartridge63 NQPU16N 2-way 1 5/16”— 12 UN66 NQPU16D 3-way 1 5/16”— 12 UN
74 NPI29V 77 NE37V79 NE45W81 NE64W
83 NS37W85 NE37W87 NSIS29V89 NSIS35V
91 NSIS45V93 NSIS45DV-M40 95 NSIS60V97 NS45W
Proportional Directional Control Valves - Manifold Mount
Proportional Directional Control Valves - Cartridge
Poppet Valves
Proportional Flow Control Valves
Proportional Pressure Reducing Valves
Solenoid Coils
7Proportional Amplifiers 100 NSD7 Digital Amplifier Controller110 NNP2 Digital Amplifier Controller115 NMD2 Digital Amplifier Controller
Technical Information 126 Hydraulic Fluids and Filtration 127 Cavity drawingsElectronics & Accessories