hunter xci polyiso installation...

27
www.hunterpanels.com 888-746-1114 Hunter Xci Polyiso Installation Guide Hunter Xci Foil, Hunter Xci Foil (Class A), Hunter Xci CG, Hunter Xci CG (Class A) or Hunter Xci 286

Upload: others

Post on 18-Jul-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

www.hunterpanels.com

888-746-1114

Hunter Xci Polyiso Installation Guide

Hunter Xci Foil, Hunter Xci Foil (Class A), Hunter Xci CG, Hunter Xci CG (Class A) or Hunter Xci 286

Page 2: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

2 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

TA B L E O F C O N T E N T S

General Guidelines and Application ...............................................................................5 - 6

XCI OA - Fastening Hunter Xci Continuous Wall Insulation .................................................7

Caulking Sealant and AdhesivesExpansion JointsMechanical Fasteners ..........................................................................................................8

4' x 8' Hunter Xci Polyiso Over Steel Stud/Standard or FRT Wood Framing with Exterior Gypsum/Plywood/OSB Sheathing and Air/Vapor/Water Resistive Barrier Detailing

XCI-1 – 4' x 8' Polyiso Insulation Fastener Pattern ................................. 10XCI-2 – 4' x 8' Polyiso Insulation Adhesive Pattern ................................ 11XCI-3 – 4' x 8' Polyiso Insulation with Brick-Ties ................................... 12

16" x 8' And 24" x 8' Hunter Xci Polyiso Over Steel Stud/Standard or FRT Wood Framing with Exterior Gypsum/Plywood/OSB Sheathing and Air/Vapor/ Water Resistive Barrier with Brick-Ties Already in Place Detailing

XCI-4 – 24" x 8' Polyiso Insulation with Brick-Ties ............13XCI-5 – 24" x 8' Polyiso Insulation with Brick-Ties ...........14XCI-6 – 16" x 8' Polyiso Insulation with Brick-Ties ............15

Termination at Foundation Detailing

XCI-7 – Polyiso Insulation Foundation Tie-In ......................................... 16

Window Sill Detailing

XCI-8 – Polyiso Insulation Punched Window - Sill .................................. 17

Page 3: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 3

TA B L E O F C O N T E N T S CONTINUED

Window Jamb Detailing

XCI-9 – Polyiso Insulation Punched Window - Jamb ............................. 18

Window Head Detailing

XCI-10 – Polyiso Insulation Punched Window - Head ........................... 19

Shelf Angle Detailing

XCI-11 – Polyiso Insulation Shelf Angle ................................................. 20

Parapet Detailing

XCI-12 – Polyiso Insulation at Parapet ................................................... 21

Expansion Joint Detailing

XCI-13 – Vertical Expansion Joint .......................................................... 22

Inside and Outside Corners Detailing

XCI-14 – Outside/Inside Corners ........................................................... 23

Mechanical/Electrical/Pipe Penetrations Detailing

XCI-15 – Pipe and Penetration Flashing ................................................ 24

Termination at Existing Construction Detailing

XCI-16 – Termination at Existing Construction ...................................... 25

Repair and Protection .......................................................................................................26

Hunter Xci Insulation Fastener Specifications ....................................................................27

Page 4: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

4 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

This application guide has been assembled to assist in the

application of Hunter Panels Xci polyisocyanurate (polyiso)

insulation board and is intended to offer guidance to

the construction community. It is intended to be used

in conjunction with current Hunter Panels published

literature. Other acceptable methods of application that

are not depicted in this guide may be incorporated during

construction provided all applications follow proven and

sound construction techniques.

Page 5: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 5

COORDINATION• Pre-construction meeting shall cover all decisions pertaining to design so that the Hunter Xci polyiso is properly installed.• Review submittals, surface preparation, installation procedures, special details, sequence of construction, responsibilities,

mock-up requirements, inspection, testing and repair procedures.• Mock-up shall establish procedures and workmanship that must be followed during installation.• Review adjacent construction materials such as windows, doors, ducts, and other penetrations for conformance to

manufacturer's application instructions.• Sequence and schedule installation of lashing and sealant to prevent damage and water infltration.• Refer to project-specifc contract documentation for components manufactured by others.

SUBSTRATE• Do not adhesively apply Hunter Xci polyiso and associated materials in ambient and substrate temperatures below 25°F.

Provide properly vented, supplementary heat during adhesive installation and drying period when temperatures less than 25°F prevail.

• Do not adhesively apply Hunter Xci polyiso and associated materials to damp or frozen surfaces.• Do not adhesively apply Hunter Xci polyiso in rain or if rain is expected a minimum of 16 hours after installation.• Protrusions, mortar droppings shall be removed from surfaces and brick-ties to facilitate ft and fnish of Hunter Xci polyiso.• Limit exposure of Hunter Xci Foil, Hunter Xci Foil (Class A), Hunter Xci 286, Hunter Xci CG, Hunter Xci CG (Class A), and

accessory products to a maximum of 60 days. If exposure limitation is exceeded, cover Hunter Xci polyiso with building wrap.

PROJECT/SITE CONDITIONS• Do not adhesively apply Hunter Xci polyiso and associated materials in ambient and substrate temperatures below 25°F.

Provide properly vented, supplementary heat during adhesive installation and drying period when temperatures less than 25°F prevail.

• Do not adhesively apply Hunter Xci polyiso and associated materials to damp or frozen surfaces.• Do not adhesively apply Hunter Xci polyiso in rain or if rain is expected a minimum of 16 hours after installation. • Protrusions, mortar droppings shall be removed from surfaces and brick-ties to facilitate fit and finish of Hunter Xci polyiso.• Limit exposure of Hunter Xci Foil, Hunter Xci Foil (Class A), Hunter Xci 286, Hunter Xci CG, Hunter Xci CG (Class A), and

accessory products to a maximum of 60 days. If exposure limitation is exceeded, cover Hunter Xci polyiso with building wrap.

DELIVERY, STORAGE AND HANDLING• Protect polyiso during transportation, storage, and installation to avoid physical damage.• Store Hunter Xci polyiso insulation boards flat and protected from direct sunlight and extreme heat.• Store Hunter Xci polyiso in a dry place protected from exposure to moisture, off the ground and covered with a waterproof

tarpaulin.

Page 6: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

6 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

APPLICATION• Protect surrounding areas and surfaces from damage.• Hunter Xci polyiso shall be installed continuously and appropriately secured to deliver its maximum impact on building energy

efficiency.• Hunter Xci polyiso shall not be applied over walls while they are vulnerable to water intrusion from above or behind.• Do not block flashing, weeps or other drainage paths with Hunter Xci polyiso insulation board.• Ensure that a pinhole void free vapor/air/water resistive barrier application is achieved prior to Hunter Xci polyiso installation.• Begin at base of wall from firm, permanent, or temporary support.• Apply Hunter Xci polyiso horizontally in a running bond pattern using maximum board lengths to minimize number of joints.

Offset Hunter Xci polyiso board joints minimum 6". Hunter Xci polyiso may be applied vertically as required.• Pre-cut Hunter Xci polyiso to fit openings and projections. Stagger vertical joints and corners. Stagger insulation and sheathing

board joints minimum 6". Hunter Xci polyiso insulation boards are cut with a knife using a square to guide the cut or table saw.• Abut all joints tightly and ensure overall flush, level surface.• Mechanically fasten Hunter Xci polyiso in accordance with proper fastening pattern as indicated. Space fasteners 12" o.c. at

perimeter and 16" o.c. in the field. Set back perimeter fasteners 3/8" from board edges and end. One washer may be used to bridge adjoining boards.

Note: (XCI OA) Where Hunter Xci polyiso is installed by the same trade as the cladding, or in close cooperation with that trade: cladding attachment hardware can supplement or replace the insulation fasteners and insulation adhesive. Cladding fasteners fulfilling insulation attachment function shall be designed for this function. If the cladding attachment is 16" o.c. or closer, and it tightly secures the insulation, no additional fastening or adhesive is required.

• When adhesive is used periodically verify adhesion. Properly installed adhesively applied Hunter Xci polyiso cohesively break while still wet and destroy the substrate when dry.

• Install Hunter Xci polyiso in accordance with proper adhesive pattern as indicated in these instructions. A drainage plane is maintained when using recommended adhesive pattern.

• Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

• Honor expansion joints as indicated on the drawings. Do not span expansion joints. • During installation take precaution to minimize moisture intrusion behind Hunter Xci polyiso.• Verify all materials are installed in accordance with current Hunter Panels published literature and local code requirements.

Page 7: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 7

Hunter Panels feels strongly that the fastening of our non-nailbase products is dependent on the cladding material attachment. With products such as these the cladding materials must be fastened back to the structural wall through the continuous insulation, therefore minimizing the total number of penetrations will assist in achieving optimal ther-mal, vapor and air barrier performance. Each wall assembly should be analyzed so that the best method for cladding attachment can assist in reducing unnecessary penetrations of the continuous insulation.

When reviewing this guide you will see 4’ x 8’ boards drawn showing 28 fasteners per board on the pages displaying mechanical attachment. This was done to illustrate typical fastener patterns for non-structural sheathing materials (fas-teners spaced 12” at perimeter and 16” in field). If cladding attachment fasteners also provide insulation securement, only a few fasteners may be required to hold the insulation board in place until the cladding is installed. Contact with the cladding manufacturer and/or the designer of the building to determine the method of attachment is recommend-ed. Hunter Panels can assist with the number of fasteners are needed after the cladding attachment information is obtained.

Fastening Continuous Wall Insulation XCI 0A

Page 8: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

8 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

CAULKING SEALANT/ADHESIVESSealants used to seal Hunter Xci polyiso insulation board gaps and gaps around penetrations where necessary. Adhesives may be used to help secure board where necessary.

During sealant installation ensure the sealant only bonds to two surfaces. It should not bond to a third surface; if it does the sealant will not properly perform. Follow sealant manufacturer's suggested application process.

NOTE: Follow application instructions by sealant manufacturer. Do not install one-part sealants into joints exceeding ½" depth.

• CCW LM-800XL• CCW 705 FR• Sure-Seal Lap Sealant• CCW-201• Sure-Seal Universal Single-Ply Sealant• Sikaflex -1A and 2C NS• NovaLink by Chem Link• NOVA-FLEX Multipurpose Adhesive Sealant

• Pecora Dynotrol I & II• Sonneborn® NP1 & NP2™• GE Silpruf, Silpruf LM• Pecora 890, 895• PL® 300 Foamboard adhesive by Loctite®• Sonneborn Premium Adhesive by BASF• Others as approved by Hunter Panels

Foam Sealant – TVM Fireblock Gun Foam can be used to fill Hunter Xci polyiso insulation board gaps. This orange-colored foam sealant expands to take the shape of the void, creating an airtight and water-resistant bond to the Hunter Xci polyiso. Applica-tion surfaces must be free of dust, debris, grease, and other contaminants that will adversely affect the bond. Moistening of the application surface will improve adhesion and cure while resulting in a more dense cellular structure. Installs in minutes and skin formation occurs in 10 minutes. Full cure time is 12-24 hours depending on project-specific weather conditions. Contact TVM Building Products directly for distribution locations and other questions relating to the Foam Sealant at 1-800-216-1223. Other similar products as approved by Hunter Panels may also be used.

EXPANSION JOINTSExpansion joint placement and design is determined by the design professional. As a general guideline, expansion joints are installed at:

• Floor lines in multi-level wood frame construction • Dissimilar substrates, materials or construction • Joints that already exist in the substrate or support construction • Changes in building height, shape or structural system• Other areas of anticipated movement• Between pre-fabricated panels

For specific expansion joint related questions regarding placement and design, Hunter Panels recommends that you contact the design professional.

Page 9: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 9

RODENHOUSE MECHANICAL FASTENERSRodenhouse, Inc. Thermal Grip® ci washers with Grip-Deck® screws are recommended for steel or wood substrates. For concrete/block/masonry substrates Plasti-Grip® PMF fasteners are recommended. Fasten Hunter Xci polyiso insulation board to steel framing member with appropriate length fastener min. 4 threads of the fastener into steel framing and min. 1" into wood framing. Space fasteners 12" o.c. at perimeter (when able) and 16" o.c. in the field. Set back perimeter fasteners 3/8" from board edges and end. One washer may be used to bridge adjoining boards The large 2" diameter of the Thermal Grip ci washer prevents blow-offs and provides excellent wind load resistance. When installed correctly, the Ther-mal Grip ci washer can effectively seal the screw penetration against air and moisture. Grip-Deck screws are provided in 1¼" – 6" in self-drilling or coarse thread for steel or wood framing. Coated screws are available for premium corrosion protection. Contact Rodenhouse, Inc. directly for distribution locations and other questions relating to the washer at 1-616-454-3100 (or toll free at 1-800-249-4747) or visit www.rodenhouse-inc.com

WIND-LOCK MECHANICAL FASTENERSWind-lock ci-LOCK continuous insulation fasteners are recommended for use with steel or wood sub-strates. These ci-LOCK fasteners combine highly coated, corrosion resistant self-tapping screws with high-grade polypropylene plates. The unique design allows the plate to flatten out during applica-tion. Large ribs stiffen the plate and limit deflection. As the EIFS industry leading “fastener of choice”, Wind-lock has been providing mechanical fastening solutions for continuous insulation systems since 1985. With the ci-LOCK continuous insulation fastener, Wind-lock has taken the next step in leading the attachment of the newest generation of continuous insulation systems. Contact Wind-lock direct-ly for distribution locations and other questions relating to their fasteners at 800-872-5625, or visit www.wind-lock.com.

NOTES1 Take special care to avoid damage to the Hunter Xci polyiso during mechanical attachment. Other

washers/fasteners designed specifically for rigid foam insulation application may be used.

Page 10: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

10 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

4'X8' HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci 286, HUNTER Xci CG OR HUNTER Xci CG (CLASS A)

APPROVED MEMBRANE BY OTHERS

NOTES1 Install approved fasteners (ref XCI-OA) 16" O/C along Stud Line and 12" O/C on perimeter.2 Adhesive may be used as a placement aid to facilitate installation

WASHER WITH FASTENER (REF XCI-0A)

1 Begin at base of wall from firm, permanent, or temporary support.

2 Apply Hunter Xci polyiso horizontally in a running bond pattern using maximum board lengths to minimize number of joints. Offset Hunter Xci polyiso board joints minimum 6". Hunter Xci polyiso may be applied vertically as required.

3 Pre-cut Hunter Xci polyiso to fit openings and projections. Stagger vertical joints and corners. Stagger insulation and sheathing board joints minimum 6". Hunter Xci polyiso insulation boards are cut with a knife using a square to guide the cut or table saw.

4 Abut all joints tightly and ensure overall flush, level surface.

5 Fasten Hunter Xci polyiso insulation board to steel framing member with appropriate length fastener min. 4 threads of the fastener into steel framing, min. 1" into wood framing. Space fasteners 12" o.c. at perimeter and 16" o.c. in the field. Set back perimeter fasteners 3/8" from board edges and end. One washer may be used to bridge adjoining boards. Drive fasteners so that washer is tight and flush with the surface of the Hunter Xci polyiso, but do not over-tighten.

4'x8' Polyiso Insulation Fastener PatternInstallation of 4' x 8' Hunter Xci Polyiso Over Steel Stud/Standard or FRT Wood Framing with Exterior Gypsum/ Plywood/OSB Sheathing and Air/Vapor/ Water Resistive Barrier

XCI 1

Page 11: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 11

NOTES1 3/8" thick by 3" diameter dabs of approved adhesive2 Begin installation at base of wall from firm, permanent, or washer w/fasteners at base (REF XCI-0A)

1 Apply 3/8" thick by 3" diameter dabs of approved adhesive to the back of Hunter Xci polyiso (side that will face sheathing) in 4 rows with a minimum of 7 dabs per row. Space adhesive dabs evenly across the length of the board at no more than 16" o.c. Space dabs in rows of no more than 16" o.c And no more than 3" from board ends and edges. Immediately place insulation boards against the wall surface before adhesive “skins". If adhesive “skins" remove and apply fresh material. If Hunter Xci polyiso insulation is applied vertically, apply 3/8" thick by 3" diameter dabs of adhesive to the back of Hunter Xci polyiso in 7 rows with a minimum of 4 dabs per row. Space adhesive dabs evenly across the length of the board at no more than 16" o.c. Space dabs in rows of no more than 16" o.c. and no more than 3" from board ends and edges.

2 Begin installation from firm support, or washer with fasteners at base.

3 Pre-cut Hunter Xci polyiso to fit openings and projections. Stagger vertical joints and corners. Stagger insulation and sheathing board joints minimum 6". Hunter Xci polyiso insulation boards are cut with a knife using a square to guide the cut or table saw.

4 Abut all joints tightly and ensure overall flush, level surface.

APPROVED MEMBRANE BY OTHERS

WASHER WITH FASTENER (REF XCI-0A)

ACCEPTABLE SHEATHING

DABS OF APPROVED ADHESIVE

4' x 8' Polyiso Insulation Adhesive PatternInstallation of 4' x 8' Hunter Xci Polyiso Over Steel Stud/ Standard or

FRT Wood Framing with Exterior Gypsum/ Plywood/OSB Sheathing and Air/Vapor/ Water Resistive Barrier

XCI 2

4'X8' HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG HUNTER Xci CG (CLASS A), ORHUNTER Xci 286

Page 12: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

12 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

NOTES1 Follow Brick Tie Manufacturer installation instructions

ACCEPTABLE SHEATHING

4'X8' HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG HUNTER Xci CG (CLASS A), OR HUNTER Xci 286

1 Follow installation recommendations from XCI 0A on page 7.

2 Barrel style brick ties may be used for mechanical attachment provided recommended spacing pattern is honored.

3 Care should be taken when installing brick ties so that undue damage is not caused to the underlying barrier or Hunter Xci polyiso.

4 Abut all joints tightly and ensure overall flush level surface.

5 Fasten Hunter Xci polyiso insulation board to steel framing member with appropriate length fastener min. 4 threads of the fastener into steel framing, min. 1" into wood framing. Space fasteners 12" o.c. at perimeter when applicable and 16" o.c. in the field. Set back perimeter fasteners 3/8" from board edges and ends. One washer may be used to bridge adjoining boards. Drive fasteners so that washer is tight and flush with the surface of the Hunter Xci polyiso, but do not over-tighten.

WASHER WITH FASTENER (REF XCI-0A)

APPROVED MEMBRANE BY OTHERS

VENEER ANCHOR, APPLIED OVER INSULATION AND FASTENED TO STUD

BRICK

4' x 8' Polyiso Insulation with Brick-TiesInstallation of 4' x 8' Hunter Xci Polyiso over Steel Stud/Standard or FRT Wood Framing with Exterior Gypsum/Plywood/OSB Sheathing and Air/Vapor/Water Resistive Barrier using brick ties for insulation attachment

XCI 3

Page 13: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 13

1 Apply 3/8"-thick by 3" diameter dabs of approved adhesive to the back of Hunter Xci polyiso (side that will face sheathing) in 2 rows with a minimum of 7 dabs per row. Space adhesive dabs evenly across the length of the board at no more than 16" o.c. Space dabs in rows of no more than 16" o.c. (12" o.c. for 16"-wide Hunter Xci polyiso) and no more than 3" from board ends and edges. Immediately place insulation boards against the wall surface before adhesive “skins". If adhesive “skins" remove and apply fresh material.

2 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

3 Verify all materials are installed in accordance with current Hunter Panels published literature and local code requirements.

NOTES1 Follow Brick Tie Manufacturer insulation instructions

DABS OF APPROVED ADHESIVE

APPROVED MEMBRANE BY OTHERS

VENEER ANCHOR, FASTENED TO STUD

FOR GAPS BETWEEN INSULATION BOARDS EXCEEDING 1/8" WIDTH: APPLY BEAD OF FOAM SEALANT, OR BUTTER EDGE OF BOARD WITH AN APPROVED ADHESIVE AND STRIKE FLUSH

16" OR 24" HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci 286, HUNTER Xci CG (CLASS A) OR HUNTER Xci CG

BRICK

ACCEPTABLE SHEATHING

16" or 24" Polyiso Insulation with Brick-TiesInstallation of 16" x 8' or 24" x 8' Hunter Xci Polyiso Over Steel Stud/Standard

or FRT Wood Framing with Exterior Gypsum/Plywood/OSB Sheathing and Air/Vapor/ Water Resistive Barrier with Brick-Ties already in place

XCI 4

Page 14: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

14 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

NOTES1 Follow Brick Tie Manufacturer insulation instructions

1 Begin at base of wall from firm, permanent, or temporary support.

2 Apply Hunter Xci polyiso horizontally in a running bond pattern using maximum board lengths to minimize number of joints. Offset Hunter Xci polyiso board joints minimum 6".

3 Pre-cut Hunter Xci polyiso to fit openings and projections. Stagger insulation and sheathing board joints minimum 6". Hunter Xci polyiso insulation boards are cut with a knife using a square to guide the cut or table saw.

4 Abut all joints tightly and ensure overall flush level surface.

5 Fasten Hunter Xci polyiso insulation board to steel framing member with appropriate length fastener min. 4 threads of the fastener into steel framing, min. 1" into wood framing. Space fasteners 12" o.c. at perimeter when applicable and 16" o.c. in the field. Set back perimeter fasteners 3/8" from board edges and ends. One washer may be used to bridge adjoining boards. Drive fasteners so that washer is tight and flush with the surface of the Hunter Xci polyiso, but do not over-tighten.

WASHER WITH FASTENER (REF XCI-0A)

APPROVED MEMBRANE BY OTHERS

VENEER ANCHOR APPLIED OVER INSULATION FASTENED TO STUD

16" OR 24" HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A) ORHUNTER Xci 286

ACCEPTABLE SHEATHING

BRICK

16" or 24" Polyiso Insulation with Brick-TiesInstallation of 16" or 24" Hunter Xci Polyiso Over Steel Stud/Standard or FRT Wood Framing with Exterior Gypsum/Plywood/OSB Sheathing and Air/Vapor/ Water Resistive Barrier with Brick-Ties

XCI 5

Page 15: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 15

1 Begin at base of wall from firm, permanent, or temporary support.

2 Apply Hunter Xci polyiso horizontally in a running bond pattern using maximum board lengths to minimize number of joints. Offset Hunter Xci polyiso board joints minimum 6".

3 Pre-cut Hunter Xci polyiso to fit openings and projections. Stagger insulation and sheathing board joints minimum 6". Hunter Xci polyiso insulation boards are cut with a knife using a square to guide the cut or table saw.

4 Abut all joints tightly and ensure overall flush, level surface.

5 Apply 3/8" thick by 3" diameter dabs of approved adhesive to the back of Hunter Xci polyiso (side that will face sheathing) in 2 rows with a minimum of 7 dabs per row. Space adhesive dabs evenly across the length of the board at no more than 16" o.c. Space dabs in rows of no more than 12" o.c. And no more than 3" from board ends and edges. Immediately place insulation boards against the wall surface before adhesive “skins". If adhesive “skins" remove and apply fresh material.

6 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved adhesive and strike flush.

7 Verify all materials are installed in accordance with current Hunter Panels published literature and local code requirements.

NOTES1 Rodenhouse, Inc. Plasti-Grip PMF fasteners (or approved equal) may be used to mechanically fasten the Hunter Xci polyiso

by pre-drilling the insulation board and CMU. The Plasti-Grip PMF fastener is inserted into the hole and applied flush with a hammer.

DABS OF APPROVED ADHESIVE

APPROVED MEMBRANE BY OTHERS

VENEER ANCHOR, FASTENED TO STUD

FOR GAPS BETWEEN INSULATION BOARDS EXCEEDING 1/8" WIDTH: APPLY BEAD OF FOAM SEALANT, OR BUTTER EDGE OF BOARD WITH APPROVED ADHESIVE AND STRIKE FLUSH

16" OR 24" HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A) ORHUNTER Xci 286

BRICK

CMU

16" or 24" wide Polyiso Insulation with Brick-TiesInstallation of 16" or 24" x 8' Hunter Xci Polyiso Over CMU and

Air/Vapor/Water Resistive Barrier with Brick-Ties Already in PlaceXCI 6

Page 16: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

16 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

1 Verify air/vapor/water resistive barrier is properly installed and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 Install membrane through-wall flashing over the air/vapor/water resistive barrier leaving the lower section loose. Incorporate termination bar and approved sealant as required.

3 Cut Hunter Xci polyiso with sloped top edge to support flashing. Mechanically or adhesively attach with minimum of one fastener or adhesive dab per linear foot.

4 Adhere membrane flashing through-wall flashing over sloped edge of Hunter Xci polyiso.

5 Cut Hunter Xci polyiso at angle to align with previous applied piece and mechanically or adhesively attach following the specified fastening and adhesive patterns above.

6 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

NOTES1 Ensure drainage path is maintained and left unobstructed.

INSULATION

INTERIOR SHEATHING

GYPSUM OR WOOD SHEATHING

STEEL OR WOOD STUDS

INSULATION APPROVED FOR BELOW GRADE OR

INTERIOR USE

APPROVED MEMBRANE BY OTHERS

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A)OR HUNTER Xci 286

THROUGH WALL FLASHINGS

WASHER WITH FASTENER (REF XCI 0A)

WEEP HOLE

GRADE

CAVITY FULLY GROUTED

WATERPROOFING APPROVED SYSTEM BY OTHERS

BELOW GRADE INSULATION

Polyiso Insulation Foundation Tie-InTermination at Foundation

XCI 7

Page 17: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 17

1 Verify air/vapor/water resistive barrier is properly installed and that the rough window opening has been properly flashed and treated and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

3 Install Hunter Xci polyiso tight against the window sill buck using either the mechanical or adhesive attachment method described previously.

WINDOW FLASHING MEMBRANE BY OTHERS

INTERIOR GYPSUM BOARD

LUMBER BUCK (OPTIONAL)

STEEL OR STANDARD OR FRT WOOD STUDS

NOTES1 Space washer with fastener 12" O/C at window perimeter

BACKER ROD

WASHER WITH FASTENER (REF XCI 0A)

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A)OR HUNTER Xci 286

EXTERIOR CLADDING

GYPSUM OR WOOD SHEATHING

APPROVED MEMBRANE BY OTHERS

Polyiso Insulation Punched Window - Sill XCI 8

Page 18: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

18 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

1 Verify air/vapor/water resistive barrier is properly installed and that the rough window opening has been properly treated and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation

2 Install Hunter Xci polyiso tight against the window jamb buck using either the mechanical or adhesive attachment method described previously.

3 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

EXTERIOR CLADDING

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A)OR HUNTER Xci 286

BACKER ROD

WASHER WITH FASTENER (REF XCI 0A)

GYPSUM OR WOOD SHEATHING

LUMBER BUCK OPTIONAL

NOTES1 Space washer with fastener 12" O/C at window perimeter.

FLASHING MEMBRANE BY OTHERS

STEEL OR STANDARD OR FRT WOOD STUD

INTERIOR SHEATHING

Polyiso Insulation Punched Window - JambXCI 9

Page 19: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 19

1 Verify air/vapor/water resistive barrier is properly installed and that the rough window opening has been properly treated and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 Install approved membrane through-wall flashing (by others) over the air/vapor/water resistive barrier leaving the lower section loose. Incorporate termination bar and approved sealant as required.

3 Cut Hunter Xci polyiso with sloped top edge to support flashing. Mechanically or adhesively attach with minimum of one fastener or adhesive dab per linear foot.

4 Adhere membrane thru-wall flashing (by others) over sloped edge of Hunter Xci polyiso.5 Cut Hunter Xci polyiso at angle to align with previous applied piece and mechanically or adhesively attach following the

specified fastening and adhesive patterns previously listed.6 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved

sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

INTERIOR SHEATHING

STANDARD OR FRT WOOD STUDS

LUMBER BUCK (OPTIONAL)

WINDOW FLASHING MEMBRANE

NOTES1 Space washer with fasterner 12" O/C at window perimeter2 Install end dams at ends of through-wall flashing3 Ensure drainage path is maintained and left unobstructed

EXTERIOR WOOD OR GYPSUM SHEATHING

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A)OR HUNTER Xci 286

EXTERIOR CLADDING

THROUGH WALL FLASHING

MEMBRANE BY OTHERS

WASHER WITH FASTENER

Polyiso Insulation Punched Window - Head XCI 10

Page 20: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

20 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

1 Verify air/vapor/water resistive barrier is properly installed and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 Install membrane through-wall flashing (by others) or other approved through- wall flashing over the air/vapor/water resistive barrier leaving the lower section loose. Incorporate termination bar and approved sealant as required.

3 Cut Hunter Xci polyiso with sloped top edge to support flashing. Mechanically or adhesively attach with minimum of one fastener or adhesive dab per linear foot.

4 Adhere membrane through-wall flashing (by others) or other approved through-wall flashing over sloped edge of Hunter Xci polyiso.

5 Cut Hunter Xci polyiso at angle to align with previous applied piece and mechanically or adhesively attach following the specified fastening and adhesive patterns previously listed.

6 Install Hunter Xci polyiso tight against underside of angle using either the mechanical or adhesive attachment method described previously.

7 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

INSULATION

INTERIOR SHEATHING

GYPSUM OR WOOD SHEATHING

STANDARD OR FRT WOOD STUDS

CONSULT XCI-13 DETAILED VIEW OF EXPANSION JOINT COMPONENTS

APPROVED MEMBRANE BY OTHERS

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A)OR HUNTER Xci 286

EXTERIOR CLADDING

WASHER WITH FASTENER (REF XCI-0A)

WEEP HOLE

SHELF ANGLE

WASHER WITH FASTENER (REF XCI-0A)

APPROVED MEMBRANE BY OTHERS

Polyiso Insulation Shelf AngleXCI 11

Page 21: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 21

1 Verify air/vapor/water resistive barrier is properly installed and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 Install Hunter Xci polyiso tight against parapet blocking using either the mechanical or adhesive attachment method described previously.

3 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

NOTES1 Ensure roofing is in place and that the building is dried, prior to Hunter Xci polyiso installation.

Polyiso Insulation at Parapet XCI 12

c 2015 CARLISLE CORPORATION

COATINGS & WATERPROOFINGR

APPROVED ROOF SYSTEMTERMINATION INCLUDING

EDGING AND SECUREMENT

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A),

HUNTER Xci CG,HUNTER Xci CG (CLASS A)

OR HUNTER Xci 286SECURED TO WALL SUBSTRATE

LAP WALL MEMBRANEAND ROOF MEMBRANE

APPROVED MEMBRANEBUY OTHERS

EXTERIOR CLADDING SECURED TO HUNTER Xci FOIL,

HUNTER Xci FOIL (CLASS A), HUNTER Xci 286 OR HUNTER Xci CG

ROOF MEMBRANE SPLICE

ROOF MEMBRANE OVER APPROVED SUBSTRATE

PREPAET WALL-TO-DECKTRANSITION. CONSULT ROOFINGMANUFACTURER DETAILS

ROOF ASSEMBLY OVER APPROVED DECK, INCLUDING MEMBRANE,

INSULATION AND ACCESSORIES

Page 22: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

22 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

1 Verify air/vapor/water resistive barrier is properly installed and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 Verify expansion joint has been properly treated.3 Install Hunter Xci polyiso against the joint but not over the joint using either the mechanical or adhesive attachment method

described. Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

NOTES1 Expansion joint placement and design is per the design professional.

Vertical Expansion JointXCI 13

LAP SEALANT

INSULATION

GYPSUM OR WOOD SHEATHING

BACKER ROD

COMPRESSIBLE INSULATION

STEEL OR STANDARD OR FRT WOOD STUDS

INTERIOR SHEATHING

RIGID PLASTIC OR METAL ANGLE

EXTERIOR CLADDING

WASHER WITH FASTENER

P/S ELASTOFORM FLASHING

WASHER WITH FASTENER

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A), ORHUNTER Xci 286

Page 23: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 23

1 Verify air/vapor/water resistive barrier is properly installed and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 With factory edges exposed, stagger vertical joints at inside and outside corners, interlocking each row of Hunter Xci polyiso. Make sure the corners are straight and plumb. Use either the mechanical or adhesive attachment method previously outlined.

3 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A), ORHUNTER Xci 286

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A), ORHUNTER Xci 286

WASHER WITH FASTENER

WASHER WITH FASTENER

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A), ORHUNTER Xci 286

Outside/Inside Corners XCI 14

TAPE THE EXPOSED FOAM ON THE OUTSIDE CORNER.

Page 24: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

24 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

1 Verify air/vapor/water resistive barrier is properly installed and a pinhole void free application has been achieved around all mechanical and electrical boxes. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 Rub the face of the mechanical/electrical box with chalk, place the Hunter Xci polyiso into place and thump the face. The profile of the box will be left on the facing. Cut along the marks and mechanically or adhesively attach the Hunter Xci polyiso as previously outlined.

3 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

SEALANT

BACKER ROD

EXTERIOR CLADDING

WASHER WITH FASTENER

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A), ORHUNTER Xci 286 MEMBRANE BY OTHERS

GYPSUM OR WOOD SHEATHING

STANDARD OR FRT WOOD STUDS

Pipe and Penetration FlashingMechanical/Electrical/Pipe Penetrations

XCI 15

Page 25: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 25

1 Verify air/vapor/water resistive barrier is properly installed and a pinhole void free application has been achieved. Report any deficiencies and ensure applicable repairs are conducted prior to Hunter Xci polyiso installation.

2 Install Hunter Xci polyiso using either the mechanical or adhesive attachment method described previously. An expansion joint may be required at the abutment, verify with the design professional.

3 Fill gaps greater than 1/8" between insulation boards with expanding spray foam or butter edge of board with approved sealant and strike flush. Expanding spray foam may also be applied onto the insulation board edges during installation.

STEEL OR STANDARD OR FRT WOOD STUDS

SEALANT

HUNTER Xci FOIL, HUNTER Xci FOIL (CLASS A), HUNTER Xci CG,HUNTER Xci CG (CLASS A)OR HUNTER Xci 286

JOINT FILLER

BACKER ROD

SEALANT

GYPSUM OR WOOD SHEATHING

EXTERIOR CLADDING

Termination at Existing Construction XCI 16

Page 26: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

26 888.746.1114 WWW.HUNTERPANELS.COM

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

Repair and Protection

Repair damage to the insulation by cutting out and replacing damage with new Hunter Xci polyiso, or filling smaller damage with foam or caulking sealant. Mechanically fastened repairs will require that the Hunter Xci polyiso be brought to the nearest framing member/stud so that proper fastening pattern can be maintained. Maximum recommended outdoor exposure of Hunter Xci Foil, Hunter Xci Foil (Class A), Hunter Xci 286, Hunter Xci CG and Hunter Xci CG (Class A) and accessory products is 60 days.

Permitted outdoor exposure can be extended by covering Hunter Xci polyiso with mechanically attached building wrap. Cover Hunter Xci polyiso with cladding as soon as schedule allows.

Page 27: Hunter Xci Polyiso Installation Guidetherm-all.com/wp-content/uploads/2018/09/Xci-Install-Guide-Part-1-O… · INSTALLATION GUIDELINES. 888.746.1114 . . 5. COORDINATION •e-construction

0417

H U N T E R X c i P O LY I S O C YA N U R AT E O V E R A I R / VA P O R B A R R I E R

I N S TA L L AT I O N G U I D E L I N E S

888.746.1114 WWW.HUNTERPANELS.COM 27

HUNTER Xci INSULATION FASTENER SPECIFICATIONS

InsulationProduct

Substrate Screw Washer

MinimumPenetration

of Screw intoSubstrate

Hunter Xci FoilHunter Xci Foil (Class A)

Hunter Xci CGHunter Xci CG (Class A)

or Hunter Xci 286

Steel Stud, 12 to 20 gauge

#2 Bugle Head Phil-lips or equivalent size, single thread, with self-tapping point

Minimum 1 ¾" diameter plastic,low profile, compress & hold insulation

Minimum 4 threads through steel stud

Standard or FRT Wood Studs

#2 Bugle Head Phil-lips or equivalent size, single thread, sharp- point wood screw

Minimum 1" depth into wood stud

WoodSheathing

All the way through sheathing + 3/8"

Concrete, Concrete Block or Masonry, Option 1

#2 Bugle Head Phillips or equiv-alent size, high & low hardened cutting threads with pyramid point

Minimum 1 ½" depth into concrete, con-crete block or ma-sonry

Concrete, Concrete Block or Masonry, Option 2

Plastic screw

Manufacturer Products

Rodenhouse, Inc.Thermal-Grip® CI Washers fitted with Grip-Deck® Screws, Plasti-Grip® PMF Fasteners for concrete/masonry substrates

Wind-Lock® CI-Lock