Page 1: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

HU

MID

ITY

MOTOR CONTROLSM

OT

OR

C

ON

TR

OL

S

Core VFD Series | p. 695 FCXLS/NFCXLS | p. 692PSR Series | p. 681

Kele Has Soft Starters and VFDs to Extend the Life of Your Motor and Help Save Energy and Maintenance Costs.

Page 2: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

MODEL/SERIES PAGEProducts manufactured in the United States

Products that are new to the catalog

ke le .com

MOTOR CONTROLS

A Series | p. 683

TEC Compact | p. 687 Starters

Smart VFD | p. 704 HVAC

MO

TO

R

CO

NT

RO

LS

Motor DisconnectsABB EOT Series — Enclosed Non-Fused Disconnect Switch . . . . . . . . . . . . .689BCXLS Series — Breaker Combination Motor Starters . . . . . . . . . . . . . . . . . .690FCXLS, NFCXLS Series — Fusible and Non-Fusible Motor Starters . . . . . . .692 Motor StartersPSR Series — Softstarters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .681A Series — ABB 3 Phase Motor Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .683TEC Compact Starters — 3 Phase Motor Starters . . . . . . . . . . . . . . . . . . . . .687 Variable Frequency Drives (VFD) and BypassesCORE VFD — Honeywell Variable Frequency Drives . . . . . . . . . . . . . . . . . . . .695CORE VFD With Bypass — Honeywell Variable Frequency Drives . . . . . . . . .698SmartDrive Compact VFD — Honeywell Compact Variable Frequency

Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .702SMARTVFD HVAC — Honeywell All Purpose Variable Frequency Drives . . . .704SMARTVFD HVAC With Bypass Assembly — Variable Frequency Drives

with Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .707

Page 3: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

681

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

Model PSR3 - 16 with MCCB Model PSR25 - 45 with MCCBL/+ N/C

PSR

Fuse(customersupplied)

Circuitprotection

by customer

Note: verify motor nameplatevoltage and horsepowerrating for soft starter selection

Sup

ply

Vol

tage

CO

M L/+ N/C

PSR

Fuse(customersupplied)

Circuitprotection

by customer

Note: verify motor nameplatevoltage and horsepowerrating for soft starter selection

Sup

ply

Vol

tage

CO

M

SOFTSTARTERSPSR SERIES

DESCRIPTION

Constant-speed AC motors are used to drive HVAC fans and pumps . During start and stop, both mechanical and electrical stresses are high, causing undesirable load peaks each time the motors are started . An ABB Softstarter eliminates many of these problems . The voltage is smoothly applied to, and removed from, the motor . Both the torque and the current consequently behave in the same way . The result is that mechanical and electrical stresses are significantly lower than with conventional starting methods .

The PSR series Compact Softstarters range covers motor currents from 3 to 46A . All sizes include a Run signal relay . The 25A and above are also provided with an output signal for TOR (Top Of Ramp, i .e . full voltage) . With standard performance the PSR Softstarters handle ten starts per hour . When an auxiliary cooling fan is added, the starting capacity is increased to 20 starts per hour .

FEATURES

• Compact size• Easy to install and adjust• DIN rail or screw mounting

Supply Voltage 100/ 240 V, 24 VDCMotor Voltage Rating 208 to 600 VACCurrent Rating PSR3 3 .9A Starting capacity 15 .6A for 6s PSR6 6 .8A Starting capacity 27 .2A for 6s PSR9 9A Starting capacity 36A for 6s PSR12 12A Starting capacity 48A for 6s PSR16 16A Starting capacity 64A for 6s PSR25 25A Starting capacity 100A for 6s PSR30 30A Starting capacity 120A for 6s PSR37 37A Starting capacity 148A for 6s PSR45 46A Starting capacity 180A for 6sHorsepower Based on rated Voltage and FLA

Acceleration Time 1-10 secondsDeceleration Time 0-20 secondsAltitude Limits 13,123 ft . (4000 m)Protection Rating Main circuit IP20 Control Circuit IP20LED Indication On/ Ready Green On/ Ready Green

Run/ Top of Ramp Green Run/ Top of Ramp Green

Operating Temperature -13° to 140°F (-25° to 60°C)Storage Temperature -40° to 158°F (-40° to 70°C)Number of Starts/ hr 10 standard; 20 with Aux . FanApprovals UL ListedFile E161428Warranty 12 months from installation,

maximum 18 months from factory

SPECIFICATIONS

WIRING

PSR30-600-70PSR45-600-70PSR16-600-70

• Run signal relay• 25A and above includes "Top Of Ramp" output signal• Motor ratings up to 600 VAC and 40Hp• Seperate Acceleration/ Deceleration times

Page 4: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

682

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

SOFTSTARTERSPSR SERIES

ORDERING INFORMATION

ACCESSORIESPSR-FAN Cooling Fan for increased starting capacity (field-installable)

ModelControl Supply Voltage

Full Load Amps

Horsepower Circuit Breaker

Max.Fuse Size Dimensions Weight

208V 240V 480V 600V

PSR3-600-70 100/ 240 V 3.4 .5 0.75 2 2 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR6-600-70 100/ 240 V 6.1 1 1.5 3 5 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR9-600-70 100/ 240 V 9 2 2 5 7.5 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR12-600-70 100/ 240 V 11 3 3 7.5 10 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR16-600-70 100/ 240 V 15.2 3 3 10 10 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR25-600-70 100/ 240 V 24.2 7.5 7.5 15 20 50 A 40 A J-Type6.30" x 1.77" x 5.04"

(160mm x 45mm x 128mm)1.43 lbs.(0.65 kg)

PSR30-600-70 100/ 240 V 28 7.5 7.5 20 25 50 A 40 A J-Type6.30" x 1.77" x 5.04"

(160mm x 45mm x 128mm)1.43 lbs.(0.65 kg)

PSR37-600-70 100/ 240 V 34 10 10 25 30 50 A 40 A J-Type7.36" x 1.77" x 6.02"

(187mm x 45mm x 153mm)2.20 lbs.(1.00 kg)

PSR45-600-70 100/ 240 V 46.2 15 15 30 40 50 A 40 A J-Type7.36" x 1.77" x 6.02"

(187mm x 45mm x 153mm)2.20 lbs.(1.00 kg)

PSR3-600-81 24 VDC 3.4 .5 .5 2 2 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)2.20 lbs.(1.00 kg)

PSR6-600-81 24 VDC 6.1 1 1 3 5 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR9-600-81 24 VDC 9 2 2 5 7.5 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR12-600-81 24 VDC 11 3 3 7.5 10 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR16-600-81 24 VDC 15.2 3 3 10 10 50 A 40 A J-Type5.51" x 1.77" x 4.47"

(140mm x 45mm x 113.5mm)0.99 lbs. (0.45 kg)

PSR25-600-81 24 VDC 24.2 7.5 7.5 15 20 100 A 60 A J- Type6.30" x 1.77" x 5.04"

(160mm x 45mm x 128mm)1.43 lbs.(0.65 kg)

PSR30-600-81 24 VDC 28 7.5 10 20 25 100 A 70 A J- Type6.30" x 1.77" x 5.04"

(160mm x 45mm x 128mm)1.43 lbs.(0.65 kg)

PSR37-600-81 24 VDC 34 10 10 25 30 150 A 100 A J- Type7.36" x 1.77" x 6.02"

(187mm x 45mm x 153mm)2.20 lbs.(1.00 kg)

PSR45-600-81 24 VDC 46.2 15 15 30 40 150 A 100 A J- Type7.36" x 1.77" x 6.02"

(187mm x 45mm x 153mm)2.20 lbs.(1.00 kg)

Page 5: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

683

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

MODEL SIZEA9, A16

A26

A50, A75

A145

A260

5.3"H x 1.7"W x 3.7"D(13.3 x 4.4 x 9.5 cm)

5.8"H x 2.1"W x 4.3"D(9.0 x 2.1 x 11.0 cm)

6.9"H x 2.8"W x 4.4"D(17.7 x 7.0 x 11.3 cm)

12.9"H x 4.1"W x 6.3"D(32.9 x 10.5 x 16.0 cm)17.5"H x 5.5"W x 7.1"D(44.4 x 14 x 18.1 cm)

Open Frame Starters in (cm)

Enclosed Starters in (cm)

NEMA 111"H x 6"W x 5"D

(27.9 x 15.2 x 12.7 cm)13"H x 9"W x 7"D

(33.0 x 22.9 x 17.8 cm)30"H x 24"W x 12"D

(76.2 x 61.0 x 30.5 cm)30"H x 24"W x 12"D

(76.2 x 61.0 x 30.5 cm)

NEMA 1 fused14"H x 12"W x 8"D

(35.6 x 30.5 x 20.3 cm)20"H x 16"W x 8"D

(50.8 x 40.6 x 20.3 cm)30"H x 24"W x 12"D

(76.2 x 61.0 x 30.5 cm)36"H x 30"W x 12"D

(91.4 x 76.2 x 30.5 cm)

NEMA 1 circuit breaker14"H x 12"W x 8"D

(35.6 x 30.5 x 20.3 cm)14"H x 12"W x 8"D

(35.6 x 30.5 x 20.3cm)24"H x 20"W x 8"D

(61.0 x 50.8 x 20.3 cm)30"H x 24"W x 12"D

(76.2 x 61.0 x 30.5 cm)

MODEL SIZEA9, A16, A26

A50, A75

A145

A260

DESCRIPTION

The A Series ABB starter line offers motor start/stop and protection . The double-break contacts allow stopping a motor with minimal conact wear . The thermal overloads are sized for the motor FLA and keep motor windings from over-heating during overload conditions . We offer these starters in open, enclosed, enclosed with fusible disconnect, and enclosed with circuit breaker . Auxiliary contacts are available for field installation .

FEATURES

• NEMA sizes 00 thru 5• UL508A panel program, file #E105450• Compact space-saving design• Auxiliary contacts available• Coil operates 85 to 110% of rated voltage• Solid-state adjustable overload relays standard• Conventional bimetallic overloads available

DIMENSIONS

ABB 3 PHASE MOTOR STARTERA SERIES

A50NSF1-84A6B A9NS1-81E

Page 6: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

684

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

ABB 3 PHASE MOTOR STARTERA SERIES

All units ship with a NO and NC contacts.Additional contacts can be added in the field.

Incoming LinesL1

L1 L2 L3

Incoming LinesL1 L2 L3

DisconnectFuse

Disconnect Breaker

1

X1

L1 L2 L3

T1M

F R

OL

OL

OL

T2 T3

T1 T2

MOTOR

MOTOR

T3

X2

3 5 1

External ControlSupply Standard 120 VAC

External ControlSupply Standard 120 VAC

CX1

2-1 1-1

3-4 3-4

3-2 3-2

3-13-7

3-7

3-6

3-5

3-3

3-6

3-3

1-2 2-2

2-1 1-1 1-2 2-2

CX23 5

98

JUM

PE

R

97

OL9695

OLM

Remote ContactCustomer

*

15

A1 A2

14

1 2

2 4 6

2 4 6

L1 L2 L3 L1 L2

X1

X2

L3

T1 T2 T3

T1 T2 T3

T1 T2 T3

DisconnectFuse

Disconnect Breaker

1 3 5 1 3 5

2 4 6

2 4 6

CX1 CX2

3-4 3-4

3-2 3-2

JUM

PE

R

FA1 A2F

F14 13

0121

0122

0121

0122

R

F

R

R

14 13

RA1 A2

Remote ContactCustomer

*

*

13 42

Non-reversing, reversingAF09 - AF750, AFN00 - AFN4

WIRING

Page 7: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

685

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

ABB 3 PHASE MOTOR STARTERA SERIES

All units ship with a NO and NC contacts.Additional contacts can be added in the field.

2-1 1-1

3-4

Jumper

3-4

3-2 3-2

3-7

3-3

3-5

3-9

3-6

1-2 2-2

2-1 1-1 1-2 2-2

DisconnectIncoming Lines

L1

SOL

SOL FOL SS

F

F

SF

S*

*F

S F

FOL

L2 L3

FuseDisconnect

External ControlSupply Standard 120VAC

Remote ContactCustomer

Breaker

1

X1L1 L2 L3 L1 L2 L3

T1 T2 T3 T1 T2 T3

T1

9514 13

14

3 1 2 4

13

96 95 96

T1 T11MOTOR*T2 T12T13

T2 T3 T1 T2 T3

X2

3 5 1

CX1 CX2

3 5

2 4 6

2 4 6

DisconnectFuse

Disconnect Breaker

1 3 5 1 3 5

2 4 6

2 4 6

0121

0122

0121

0122

A1 A2

A1 A2

3-2 3-2

3-7

3-3

3-53-9

3-6

SOL FOL95 96 95 96

S

2F14 13

14 13

1F

S0121

0122

0121

0122

2F

1F

14 13

21 22

S*

*F

Remote ContactCustomer

3 1 2 4

A1 A2

2F

1F

A1 A2

SA1 A2

Jumper

3-4 3-4

External ControlSupply Standard 120VAC

CX1 CX2

2 speed, 1 winding; 2 speed, 2 windingAF09 - AF75

WIRING

Page 8: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

686

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

ORDERING INFORMATION

NEMASIZE00

0

1

2

3

4

5

200V–––

1/3, 1/41/23/4–1

1.5–23–5

7.5––10–152025––30405060–

230V–

1/41/31/2–

3/41

1.5––23–5

7.5–1015––20

25, 30––4050–60100

460V1/4

1/3, 1/23/41–

1.5, 2–––35–

7.510–152025–304050–6075100–

125200

575V1/2–

3/41

1.5, 2––––5––10––2025–304050–6075100–

125150–

OVERLOADRELAY

SETTINGRANGE

0.63 - 1.01.0 - 1.41.3 - 1.61.7 - 2.42.2 - 3.12.8 - 4.03.5 - 5.04.5 - 6.56.0 - 8.54.5 - 6.56.0 - 8.57.5 - 1110 - 1413 - 1918 - 2518 - 2522 - 3229 - 4229 - 4236 - 5245 - 6360 - 8065 - 9065 - 9065 - 9065 - 90

110 - 150130 - 185220 - 310

MODELOPEN STYLE

A9N00S-*EA9N00S-*FA9N00S-*GA9N00S-*HA9N00S-*JA9N00S-*KA9N00S-*LA9N00S-*MA9N00S-*NA16N0S-*MA16N0S-*NA16N0S-*PA26N1S-*QA26N1S-*RA26N1S-*SA50N2S-*AA50N2S-*BA50N2S-*CA75N3S-*CA75N3S-*DA75N3S-*EA75N3S-*F

A145N4S-*RA145N4S-*AA145N4S-*BA145N4S-*CA260N5S-*TA260N5S-*AA260N5S-*C

MODELNEMA 1

ENCLOSEDA9NS1-*EA9NS1-*FA9NS1-*GA9NS1-*HA9NS1-*JA9NS1-*KA9NS1-*LA9NS1-*MA9NS1-*N

A16NS1-*MA16NS1-*NA16NS1-*PA26NS1-*QA26NS1-*RA26NS1-*SA50NS1-*AA50NS1-*BA50NS1-*CA75NS1-*CA75NS1-*DA75NS1-*EA75NS1-*F

A145NS1-*RA145NS1-*AA145NS1-*BA145NS1-*CA260NS1-*TA260NS1-*AA260NS1-*C

FUSECLIPSIZE

CLASSJ

30A30A30A30A30A30A30A30A30A30A30A30A30A30A30A60A60A60A100A100A100A100A400A400A400A400A400A400A400A

MODELNEMA 1ENCL.

FUSIBLEDISCONNECTA9NSF1-*E6AA9NSF1-*F6AA9NSF1-*G6AA9NSF1-*H6AA9NSF1-*J6AA9NSF1-*K6AA9NSF1-*L6AA9NSF1-*M6AA9NSF1-*N6A

A16NSF1-*M6AA16NSF1-*N6AA16NSF1-*P6AA26NSF1-*Q6AA26NSF1-*R6AA26NSF1-*S6AA50NSF1-*A6BA50NSF1-*B6BA50NSF1-*C6BA75NSF1-*C6CA75NSF1-*D6CA75NSF1-*E6CA75NSF1-*F6C

A145NSF1-*R6EA145NSF1-*A6EA145NSF1-*B6EA145NSF1-*C6EA260NSF1-*T6EA260NSF1-*A6EA260NSF1-*C6E

MODELNEMA 1ENCL.

W/CIRCUITBREAKER

A9NSM1-*E4AA9NSM1-*F4AA9NSM1-*G4AA9NSM1-*H4AA9NSM1-*J4BA9NSM1-*K4BA9NSM1-*L4CA9NSM1-*M4CA9NSM1-*N4C

A16NSM1-*M4CA16NSM1-*N4CA16NSM1-*P4DA26NSM1-*Q4DA26NSM1-*R4DA26NSM1-*S4EA50NSM1-*A4EA50NSM1-*B4EA50NSM1-*C4EA75NSM1-*C4EA75NSM1-*D4FA75NSM1-*E4FA75NSM1-*F4F

A145NSM1-*R4FA145NSM1-*A4FA145NSM1-*B4FA145NSM1-*C4FA260NSM1-*T4HA260NSM1-*A4HA260NSM1-*C4J

CIRCUITBREAKER

RATING(480 V MAX)

33335510101010102525255050505050100100100100100100100250250400

MOTOR HORSEPOWER3-PHASE, 1800 RPM**

*Insert code 84 for 120 VAC 60Hz, code 80 for 240 VAC, code 81 for 24 VAC 50/60 Hz**Check full load amp rating on motor nameplate to ensure proper overload protectionNote - for additional auxiliary contacts add suffix 10 for 1 N.O., 20 for 2 N.O., 01 for 1 N.C., 02 for 2 N.C., 11 for 1 N.O. & 1 N.C.Example: A50N2S-84A-20 Open frame style, 10 HP, 120 VAC coil, 2 N.O. auxiliary contacts

ABB 3 PHASE MOTOR STARTERA SERIES

All units ship with a NO and NC contacts.Additional contacts can be added in the field.

Incoming LinesL1

L1 L2Disconnect

FuseDisconnect Breaker

1

X1

L1 L2 L3

T1M

OL

OL

T2 T3

T1 T2

MOTOR

T3

X2

3 5 1

External ControlSupply Standard 120 VAC

CX1

2-1 1-1

3-4 3-4

3-2 3-2

3-13-7

3-6

3-3

1-2 2-2

CX23 5

98

JUM

PE

R

97

OL9695

OLM

Remote ContactCustomer

*

15

A1 A2

14

1 2

2 4 6

2 4 6

Non-reversing, single phaseAF09 - AF110, AFN00 - AFN2

WIRING

Page 9: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

687

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

C D

TEC12, TEC18 Starters TEC25 StarterA 4.72" (11.98 cm) 5.31" (13.48 cm)

B 5.51" (18.99 cm) 6.1" (15.49 cm)

C 6.54" (16.61 cm) 7.28" (18.49 cm)

D 5.9" (14.98 cm) 6.5" (16.51 cm)

E 3.46" (8.78 cm) 3.98" (10.10 cm)

A

BE

DESCRIPTION

TEC Compact Starters are compact 3 phase motor starters .They have an enameled copper wire coil and have finger-safe contacts .These starters are UL 508SB rated . There is an external window indicator that shows contact wear .

FEATURES

• Compact design• cULus, CE, and UL508 approved• Available with reset or start stop• NEMA 4X enclosed• Single or three phase• Class 10 overloads

DIMENSIONS

3 PHASE MOTOR STARTERSTEC COMPACT STARTERS

TEC18-AKSS3-18A

SPECIFICATIONS

HORSE POWER - 3PHASE

Part Number 200V 230V 480V 600VCoil

VoltageEnclosure

NEMA RatingControl Type/

VersionOverload Amp

RangeWeight lbs (kg)

TEC12-A4XR-8A 2 2.5 5 7.5 120V 4X Reset only 5.5 - 8A 2.3 (1.04)

TEC12-G4XR-8A 2 2.5 5 7.5 24V 4X Reset only 5.5 - 8A 2.3 (1.04)

TEC12-AKSS3-8A 2 2.5 5 7.5 120V 4X Start/stop 5.5 - 8A 2.3 (1.04)

TEC12-GKSS3-8A 2 2.5 5 7.5 24V 4X Start/stop 5.5 - 8A 2.3 (1.04)

TEC12-A4XR-13A 3 3 7.5 10 120V 4X Reset only 9 - 13A 2.3 (1.04)

TEC12-G4XR-13A 3 3 7.5 10 24V 4X Reset only 9 - 13A 2.3 (1.04)

TEC12-AKSS3-13A 3 3 7.5 10 120V 4X Start/stop 9 - 13A 2.3 (1.04)

TEC12-GKSS3-13A 3 3 7.5 10 24V 4X Start/stop 9 - 13A 2.3 (1.04)

TEC18-A4XR-18A 5 5 10 15 120V 4X Reset only 7 - 10A 2.3 (1.04)

TEC18-G4XR-18A 5 5 10 15 24V 4X Reset only 7 - 10A 2.3 (1.04)

TEC18-AKSS3-18A 5 5 10 15 120V 4X Start/stop 7 - 10A 2.3 (1.04)

TEC18-GKSS3-18A 5 5 10 15 24V 4X Start/stop 7 - 10A 2.3 (1.04)

TEC25-A4XR-25A 5 7.5 15 20 120V 4X Reset only 17- 25A 2.7 (1.22)

TEC25-G4XR-25A 5 7.5 15 20 24V 4X Reset only 17- 25A 2.7 (1.22)

TEC25-AKSS3-25A 5 7.5 15 20 120V 4X Start/stop 17- 25A 2.7 (1.22)

TEC25-GKSS3-25A 5 7.5 15 20 24V 4X Start/stop 17- 25A 2.7 (1.22)

Other options and models available from manufacturer.

Page 10: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

688

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

ORDERING INFORMATION

MODEL DESCRIPTIONTEC12-A4XR-8A Compact starter, 3 phase, 120 VAC, with reset and overload,5.5 to 8 AmpsTEC12-G4XR-8A Compact starter, 3 phase, 24 VAC, with reset and overload, 5.5 to 8 AmpsTEC12-AKSS3-8A Compact starter, 3 phase, 120 VAC, start/stop and overload, 5.5 to 8 AmpsTEC12-GKSS3-8A Compact starter, 3 phase, 24 VAC, start/stop and overload, 5.5 to 8 AmpsTEC12-A4XR-13A Compact starter, 3 phase, 120 VAC, with reset and overload, 9 to 13 AmpsTEC12-G4XR-13A Compact starter, 3 phase, 24 VAC, with reset and overload, 9 to 13 AmpsTEC12-AKSS3-13A Compact starter, 3 phase, 120 VAC, start/stop and overload, 9 to 13 AmpsTEC12-GKSS3-13A Compact starter, 3 phase, 24 VAC, start/stop and overload, 9 to 13 AmpsTEC18-A4XR-18A Compact starter, 3 phase, 120 VAC, with reset and overload, 12 to 18 AmpsTEC18-G4XR-18A Compact starter, 3 phase, 24 VAC, with reset and overload, 12 to 18 AmpsTEC18-AKSS3-18A Compact starter, 3 phase, 120 VAC, start/stop and overload, 12 to 18 AmpsTEC18-GKSS3-18A Compact starter, 3 phase, 24 VAC, start/stop and overload, 12 to 18 AmpsTEC25-A4XR-25A Compact starter, 3 phase, 120 VAC, with reset and overload, 17 to 25 AmpsTEC25-G4XR-25A Compact starter, 3 phase, 24 VAC, with reset and overload, 17 to 25 AmpsTEC25-AKSS3-25A Compact starter, 3 phase, 120 VAC, start/stop and overload, 17 to 25 AmpsTEC25-GKSS3-25A Compact starter, 3 phase, 24 VAC, start/stop and overload, 17 to 25 Amps

ACCESSORIES EEC0.63-1A Overload relay TEC Series/0.63-1 AmpsEEC1-1.6A Overload relay TEC Series/1-1.6 AmpsEEC1.6-2.5A Overload relay TEC Series/1.6-2.5 AmpsEEC2.5-4A Overload relay TEC Series/2.5-4 AmpsEEC4-6A Overload relay TEC Series/4-6 AmpsEEC5.5-8A Overload relay TEC Series/5.5-8 AmpsEEC7-10A Overload relay TEC Series/7-10 AmpsEEC9-13A Overload relay TEC Series/9-13 AmpsEEC12-18A Overload relay TEC Series/12-18 AmpsEEC17-25A Overload relay TEC Series/17-25 Amps

3 PHASE MOTOR STARTERSTEC COMPACT STARTERS

L1

13M

L1(X1)

14 A1 A2 95 96

(A) (B)

17 18

T1

L1

L2

M

OL

OL RESET

STOP L2(X2)

T2

L2

T3

MTR

M

START

THREE-PHASE** L2 on control circuit should be connected to neutral for 120V control voltage. Dashed lines indicate field connection.

START-STOP PUSHBUTTONS Series TEC…KSS3…*

L3

L1

T1

L1

L2

M13

14Aux. NO

OL

L2

T2

MTR

SINGLE-PHASE*

13M

L1(X1)

14 A1 A2 95 96

(A) (B)

17 18

OL RESET

STOP L2(X2)

M

START

REMOTE START-STOP PUSHBUTTONS Series TEC…4XR… (Reset only)*

WIRING

Page 11: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

689

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

Supply Voltage 600V MAXEnclosure Rating NEMA 3R/12Auxiliary Contacts (optional)

Maximum number allowed: 2NO + 1NC

Meets ARRA or BAA YesDimensions, Including Handle EOT16 & EOT32 6 .36"H x 3 .94"W x 4 .55"D

(16 .2 x 10 x 11 .6 cm) EOT45 7 .87"H x 5 .75"W x 5 .43"D

(19 .8 x 14 .6 x 18 .8 cm) EOT63 11 .81"H x 8 .27"W x 7 .12"D

(30 x 21 x 181 cm)Approvals UL Listed E63822, IEC947-3, UL 508Note: Only 1 additional pole per switch allowed

DESCRIPTIONThe EOT Series of enclosed manual motor controllers are rotary operated, 3 pole, 600V Hp rated switches, housed in thermoplastic/polycarbonate enclosures suitable for wet and corrosive environments . These NEMA 3R/12 models are equipped with selector style handles . They are compact in size have touch safe operation . cUL/IEC-47-3 approvals and UL508 listed .

FEATURES• Suitable as motor disconnect• Horsepower rated• Touch safe construction• Positive operation• Clear position indication• Self lifting tunnel terminals• Extremely compact size• Accessories include 4th Power Pole & Snap-on auxiliary

contacts• OSHA Lock Out/Tag Out

ENCLOSED NON-FUSED DISCONNECT SWITCHABB EOT SERIES

Selector switch style

EOT products are properly installed on the load side of abranch circuit protective device and are suitable for use asmotor disconnects as illustrated above.

Disconnect means

Short Circuit protective device

Controller

Overload protection

EOT Motor disconnect

WIRING

ORDERING INFORMATION

MODEL DESCRIPTIONEOT16U3P3-S Black selector handle; 16 Amp ratingEOT16U3P3-1S Black selector handle; 16 Amp rating;

1 NO auxiliary contactEOT16U3P3-S1 Red/Yellow selector handle; 16 Amp ratingEOT16U3P3-1S1 Red/Yellow selector handle; 16 Amp rating;

1 NO auxiliary contactEOT32U3P3-S Black selector handle; 40 Amp ratingEOT32U3P3-1S Black selector handle; 40 Amp rating;

1 NO auxiliary contactEOT32U3P3-S1 Red/Yellow selector handle; 40 Amp ratingEOT32U3P3-1S1 Red/Yellow selector handle; 40 Amp rating;

1 NO auxiliary contactEOT45U3P3-S Black selector handle; 60 Amp ratingEOT45U3P3-1S Black selector handle; 60 Amp rating;

1 NO auxiliarycontactEOT45U3P3-S1 Red/Yellow selector handle; 60 Amp ratingEOT45U3P3-1S1 Red/Yellow selector handle; 60 Amp rating;

1 NO auxiliary contactEOT63U3P3-P Black pistol handle; 80 Amp ratingEOT63U3P3-1P Black pistol handle; 80 Amp rating;

1 NO auxiliary contactEOT63U3P3-P1 Red/Yellow pistol handle; 80 Amp ratingEOT63U3P3-1P1 Red/Yellow pistol handle; 80 Amp rating;

1 NO auxiliary contact

ACCESSORIESOA1G01 Auxiliary contact NC, mounts on left side of switch onlyOA1G10 Auxiliary contact, NO mounts on right side of switch onlyOTPL40FP 4th Pole, late-break/early-make function (eOT16 & eOT32)OTPL80FP 4th Pole, late-break/early-make function (eOT45 & eOT63)OTPS40FP 4th Pole (EOT16 & eOT32)OTPS80FP 4th Pole (EOT45 & eOT63)

HORSEPOWER RATINGSModel Series eOT16 eOT32 eOT45 eOT63Three Phase Max HP200-208V 3 10 15 20240V 6 10 15 20480V 10 20 30 40600V 10 25 30 40Single Phase Max HP120V 1 2 2 2240V 2 5 7.5 10

SPECIFICATIONS

Page 12: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

690

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

BREAKER COMBINATION MOTOR STARTERSBCXLS SERIES

DESCRIPTION

Breaker combnation motor starters are UL508 . They include 600 Volt internatinally accepted industrial control breakers with instantaneous and thermal trip . They all have door handle safety interlocks and pilot lights . Magnetic starters with percision and consisten overload protection and different single phasing protection .

FEATURES

• Breakers with instantaneous and thermal trip• NEMA 1 or NEMA 12/4 enclosure• Space and drilling for fused control circuit transformer• HOA switch• Pilot light • Door safety interlocks• 24V or 120V coil voltage• UL File #E90628

BCXLS11K-1G-0N-M01-H0A-PL

FUSIBLE CONTROL TRANSFORMERSModel Primary Volts Secondary Volts Continuous VA Contactors to use with Height Width Depth

B050MBT713RK 208V, 230V, 460V 115V, 24V 50VA LS07,4,7,17,27,37, LS05,4K,7K,11K,18K 3.25" (83 mm) 3.0" (76 mm) 3.93" (100 mm)B100MBT713RK 208V, 230V, 460V 115V, 24V 100VA LS47,57,77,87,107 ,LS22K,30K,37K,45K, LS55K 3.62"(92 mm) 3.75" (95 mm) 4.55" (76 mm) B150MBT713RK 208V, 230V, 460V 115V, 24V 150VA LS177, LS75K LS90K(3P) 4.37" (111 mm) 3.75" (95 mm) 4.55" (76 mm) B200MBT713RK 208V, 230V, 460V 115V, 24V 200VA LS247 LS110K, 132K, 160K 4.5" (114 mm) 4.5" (114 mm) 5.18" (132 mm)B250MBT713RK 208V, 230V, 460V 115V, 24V 250VA LS220K, 280K, 375K 5.25" (133 mm) 4.5" (114 mm) 5.18" (132 mm)B300MBT713RK 208V, 230V, 460V 115V, 24V 300VA LS450K 5.12" (130 mm) 5.25" (133 mm) 6.12" (155 mm)B350MBT713RK 208V, 230V, 460V 115V, 24V 350VA 5.37" (137 mm) 5.25" (133 mm) 6.12" (155 mm)

BREAKER COMBINATION

L1

H1

T1

L2

H4

L3

T3

14

13M

M

A1

A1 X2

95 96

L2

A2

OL

Aux. NO

OL

T2

MTR

RA1 A2

X2

L2

X1

L1

ON PL

OFF PL

PILOT LIGHTSTRANSFORMER

CONTROL CIRCUIT

21 22M

H3 H2

FU

X1 X2

G

H1(L1) H4(L2)

X2

L2

X1

L1 95 96A1 A2

13 14

OFFHAND AUTO

REMOTE SWITCH

23 24 1

OL

M

2

X1

L1START

AUX

STOP

X2

L295 96A1 A221

13 14

13 14

22OL

M

X1

L1OFF ON

X2

L295 96A1 A2

13 14

OL

M

WIRING

Page 13: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

691

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

BREAKER COMBINATION MOTOR STARTERSBCXLS SERIES

ORDERING INFORMATION/SPECIFICATIONS

Part Number HP Voltage Coil Voltage

Enclosure NEMA Rating

Coil Inrush

Coil Holding Current

Overload Range

Breaker Rating

Dimensions in (lb)

Weight lb (kg)

BCXLS7K-1G-O-M01-HOA-PL

5 200/23024 VAC

1

45 VA 6 VA 14.5-18 Amps 30A 16" x 12" x 8"

(40.6 x 30.5 x 20.3) 31 (14.1)BCXLS7K-1G-O-M4-HOA-PL 12/4BCXLS7K-1A-O-M01-HOA-PL

120 VAC1

BCXLS7K-1A-O-M4-HOA-PL 12/4BCXLS7K-2G-O-M01-HOA-PL

10 46024 VAC

1

45 VA 6 VA 14.5-18 Amps 30A 16" x 12" x 8"

(40.6 x 30.5 x 20.3) 31 (14.1)BCXLS7K-2G-O-M4-HOA-PL 12/4BCXLS7K-2A-O-M01-HOA-PL

120 VAC1

BCXLS7K-2A-O-M4-HOA-PL 12/4BCXLS11K-1G-ON-M01-HOA-PL

7.5 23024 VAC

1

88 VA 9 VA 21-26 Amps 50A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 32 (14.5)

BCXLS11K-1G-ON-M4-HOA-PL 12/4BCXLS11K-1A-ON-M01-HOA-PL

120 VAC1

BCXLS11K-1A-ON-M4-HOA-PL 12/4BCXLS11K-2G-ON-M01-HOA-PL

15 46024 VAC

1

88 VA 9 VA 21-26 Amps 50A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 32 (14.5)

BCXLS11K-2G-ON-M4-HOA-PL 12/4BCXLS11K-2A-ON-M01-HOA-PL

120 VAC1

BCXLS11K-2A-ON-M4-HOA-PL 12/4BCXLS15K-1G-Q-M01-HOA-PL

10 20024 VAC

1

88 VA 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15)

BCXLS15K-1G-Q-M4-HOA-PL 12/4BCXLS15K-1A-Q-M01-HOA-PL

120 VAC1

BCXLS15K-1A-Q-M4-HOA-PL 12/4BCXLS15K-2G-Q-M01-HOA-PL

10 23024 VAC

1

88 VA 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15)

BCXLS15K-2G-Q-M4-HOA-PL 12/4BCXLS15K-2A-Q-M01-HOA-PL

120 VAC1

BCXLS15K-2A-Q-M4-HOA-PL 12/4BCXLS15K-3G-Q-M01-HOA-PL

20 46024 VAC

1

88 VA 9 VA 30-40 Amps 80A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 33 (15)

BCXLS15K-3G-Q-M4-HOA-PL 12/4BCXLS15K-3A-Q-M01-HOA-PL

120 VAC1

BCXLS15K-3A-Q-M4-HOA-PL 12/4BCXLS22K-1G-RN-M01-HOA-PL

15 200/23024 VAC

1

191 VA 17 VA 54-65 Amps 125A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 45 (20.4)

BCXLS22K-1G-RN-M4-HOA-PL 12/4BCXLS22K-1A-RN-M01-HOA-PL

120 VAC1

BCXLS22K-1A-RN-M4-HOA-PL 12/4BCXLS22K-2G-QN-M01-HOA-PL

30 46024 VAC

1

191 VA 17 VA 42-55 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 45 (20.4)

BCXLS22K-2G-QN-M4-HOA-PL 12/4BCXLS22K-2A-QN-M01-HOA-PL

120 VAC1

BCXLS22K-2A-QN-M4-HOA-PL 12/4BCXLS37K-1G-SN-M01-HOA-PL

20/25 200/23024 VAC

1

191 VA 17 VA 64-82 Amps 150A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 47 (21.3)

BCXLS37K-1G-SN-M4-HOA-PL 12/4BCXLS37K-1A-SN-M01-HOA-PL

120 VAC1

BCXLS37K-1A-SN-M4-HOA-PL 12/4BCXLS37K-2G-SN-M01-HOA-PL

50 46024 VAC

1

191 VA 17 VA 64-82 Amps 150A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 47 (21.3)

BCXLS37K-2G-SN-M4-HOA-PL 12/4BCXLS37K-2A-SN-M01-HOA-PL

120 VAC1

BCXLS37K-2A-SN-M4-HOA-PL 12/4BCXLS45K-1G-TM-M01-HOA-PL

25/30 200/23024 VAC

1

191 VA 17 VA 78-97 Amps 150A 24" x 20" x 8" (61 x 50.8 x 20.3) 61 (27.7)

BCXLS45K-1G-TM-M4-HOA-PL 12/4BCXLS45K-1A-TM-M01-HOA-PL

120 VAC1

BCXLS45K-1A-TM-M4-HOA-PL 12/4BCXLS45K-2G-TM-M01-HOA-PL

60 46024 VAC

1

191 VA 17 VA 78-97 Amps 150A 24" x 20" x 8" (61 x 50.8 x 20.3) 61 (27.7)

BCXLS45K-2G-TM-M4-HOA-PL 12/4BCXLS45K-2A-TM-M01-HOA-PL

120 VAC1

BCXLS45K-2A-TM-M4-HOA-PL 12/4BCXLS55K-1G-TN-M01-HOA-PL

40 23024 VAC

1

191 VA 17 VA 90-110 Amps 175A 24" x 20" x 8" (61 x 50.8 x 20.3) 63 (28.6)

BCXLS55K-1G-TN-M4-HOA-PL 12/4BCXLS55K-1A-TN-M01-HOA-PL

120 VAC1

BCXLS55K-1A-TN-M4-HOA-PL 12/4BCXLS55K-2G-TN-M01-HOA-PL

75 460 24 VAC

1

191 VA 17 VA 90-110 Amps 175A 24" x 20" x 8" (61 x 50.8 x 20.3) 63 (28.6)

BCXLS55K-2G-TN-M4-HOA-PL 12/4BCXLS55K-2A-TN-M01-HOA-PL 1BCXLS55K-2A-TN-M4-HOA-PL 12/4BCXLS75K-1G-TT-M01-HOA-PL

40/50 200/23024 VAC

1

400 VA 32 VA 140-190 Amps 225A 30" x 24" x 8"

(76.2 x 61 x 20.3) 97 (44)BCXLS75K-1G-TT-M4-HOA-PL 12/4BCXLS75K-1A-TT-M01-HOA-PL

120 VAC1

BCXLS75K-1A-TT-M4-HOA-PL 12/4BCXLS75K-2G-TT-M01-HOA-PL

100 46024 VAC

1

400 VA 32 VA 140-190 Amps 225A 30" x 24" x 8"

(76.2 x 61 x 20.3) 97 (44)BCXLS75K-2G-TT-M4-HOA-PL 12/4BCXLS75K-2A-TT-M01-HOA-PL

120 VAC1

BCXLS75K-2A-TT-M4-HOA-PL 12/4

Page 14: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

692

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

FUSIBLE AND NON-FUSIBLE MOTOR STARTERSFCXLS, NFCXLS SERIES

DESCRIPTION

Fusible and Non-Fusible combination controls for your motor. These have UL/CSA manual motor disconnects with door safety interlocks. Industrial controls disconnects are load make, load break, UL listed for motor load switching duty. Starter and overload relay complete with precision ambient compensated heaters and differential single phasing protection.

FEATURES

• NEMA 1 or NEMA 12/4 enclosure• Space and drilling for fused control circuit transformer• HOA switch• Pilot light • Door safety interlocks• 24V or 120V coil voltage• UL File #E90628 FCXLS7K-2A-0-M4-HOA-PL

RA1 A2

X2

L2

X1

L1

ON PL

OFF PL

PILOT LIGHTSTRANSFORMER

CONTROL CIRCUIT

21 22M

H3 H2

FU

X1 X2

G

X2

L2

X1

L1 95 96A1 A2

13 14

OFFHAND AUTO

REMOTE SWITCH

23 24 1

OL

M

H1(L1) H4(L2)

2

M

X1

L1START

AUX

STOP

X2

L295 96A1 A221

13 14

13 14

22OL

X1

L1OFF ON

X2

L295 96A1 A2

13 14

OL

M

FUSIBLE COMBINATION

M

A1

A1 X2

95 96

L2

A2

OL

L1

H1

T1

L2

H4

L3

T3

M

OL

T2

MTR

WIRING

FUSIBLE CONTROL TRANSFORMERSModel Primary Volts Secondary Volts Continuous VA Contactors to use with Height Width Depth

B050MBT713RK

208V, 230V, 460V 115V, 24V

50VA LS07,4,7,17,27,37, LS05,4K,7K,11K,18K 3.25" (83mm) 3.0" (76mm) 3.93" (100mm

B100MBT713RK 100VA LS47,57,77,87,107 ,LS22K,30K,37K,45K, LS55K 3.62"(92mm) 3.75" (95mm) 4.55" (76mm)

B150MBT713RK 150VA LS177, LS75K LS90K(3P) 4.37" (111mm) 3.75" (95mm) 4.55" (76mm)

B200MBT713RK 200VA LS247 LS110K, 132K, 160K 4.5" (114mm) 4.5" (114mm) 5.18" (132mm)

B250MBT713RK 250VA LS220K, 280K, 375K 5.25" (133mm) 4.5" (114mm) 5.18" (132mm)

B300MBT713RK 300VA LS450K 5.12" (130mm) 5.25" (133mm) 6.12" (155mm)

B350MBT713RK 350VA 5.37" (137mm) 5.25" (133mm) 6.12" (155mm)

Page 15: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

693

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

FUSIBLE AND NON-FUSIBLE MOTOR STARTERSFCXLS, NFCXLS SERIES

ORDERING INFORMATION - FCXLS

Part Number HP Voltage Coil

VoltageEnclosure

NEMA RatingCoil

InrushCoil Holding

CurrentOverload

RangeFuse Block

RatingDimensions

in (cm)Weight lb (kg)

FCXLS7K-1G-O-M01-HOA-PL

5 200/23024 VAC 1

45 VA 6 VA 14.5-18 30A 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.16)FCXLS7K-1G-O-M4-HOA-PL 12/4

FCXLS7K-1A-O-M01-HOA-PL 120 VAC 1FCXLS7K-1A-O-M4-HOA-PL 12/4FCXLS7K-2G-O-M01-HOA-PL

10 46024 VAC

1

45 VA 6 VA 14.5-18 Amps 30A 12" x 10" x 6"

(30.5 x 25.4 x 15.2) 18 (8.16)FCXLS7K-2G-O-M4-HOA-PL 12/4FCXLS7K-2A-O-M01-HOA-PL 120 VAC 1FCXLS7K-2A-O-M4-HOA-PL 12/4FCXLS11K-1G-ON-M01-HOA-PL

7.5 23024 VAC 1

88 VA 9 VA 21-26 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 18 (8.16)FCXLS11K-1G-ON-M4-HOA-PL 12/4

FCXLS11K-1A-ON-M01-HOA-PL 120 VAC 1FCXLS11K-1A-ON-M4-HOA-PL 12/4FCXLS11K-2G-ON-M01-HOA-PL

15 46024 VAC 1

88 VA 9 VA 21-26 Amps 30A 12" x 10" x 6" (30.5 x 25.4 x 15.2)

18 (8.16)18 (8.16)18 (8.16)18 (8.16)

FCXLS11K-2G-ON-M4-HOA-PL 12/4FCXLS11K-2A-ON-M01-HOA-PL 120 VAC 1FCXLS11K-2A-ON-M4-HOA-PL 12/4FCXLS15K-1G-Q-M01-HOA-PL

10 20024 VAC 1

88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)FCXLS15K-1G-Q-M4-HOA-PL 12/4

FCXLS15K-1A-Q-M01-HOA-PL 120 VAC 1FCXLS15K-1A-Q-M4-HOA-PL 12/4FCXLS15K-2G-Q-M01-HOA-PL

10 23024 VAC 1

88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)FCXLS15K-2G-Q-M4-HOA-PL 12/4

FCXLS15K-2A-Q-M01-HOA-PL 120 VAC 1FCXLS15K-2A-Q-M4-HOA-PL 12/4FCXLS15K-3G-Q-M01-HOA-PL

20 46024 VAC 1

88 VA 9 VA 30-40 Amps 60A 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)

FCXLS15K-3G-Q-M4-HOA-PL 12/4FCXLS15K-3A-Q-M01-HOA-PL 120 VAC 1FCXLS15K-3A-Q-M4-HOA-PL 12/4FCXLS22K-1G-RN-M01-HOA-PL

15 200/23024 VAC 1

191 VA 17 VA 54-65 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 41 (18.6)FCXLS22K-1G-RN-M4-HOA-PL 12/4

FCXLS22K-1A-RN-M01-HOA-PL 120 VAC 1FCXLS22K-1A-RN-M4-HOA-PL 12/4FCXLS22K-2G-QN-M01-HOA-PL

30 46024 VAC 1

191 VA 17 VA 42-55 Amps 60A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 41 (18.6)FCXLS22K-2G-QN-M4-HOA-PL 12/4

FCXLS22K-2A-QN-M01-HOA-PL 120 VAC 1FCXLS22K-2A-QN-M4-HOA-PL 12/4FCXLS37K-1G-SN-M01-HOA-PL

20/25 200/23024 VAC 1

191 VA 17 VA 64-82 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 42 (19.1)FCXLS37K-1G-SN-M4-HOA-PL 12/4

FCXLS37K-1A-SN-M01-HOA-PL 120 VAC 1FCXLS37K-1A-SN-M4-HOA-PL 12/4FCXLS37K-2G-SN-M01-HOA-PL

50 46024 VAC 1

191 VA 17 VA 64-82 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 42 (19.1)FCXLS37K-2G-SN-M4-HOA-PL 12/4

FCXLS37K-2A-SN-M01-HOA-PL 120 VAC 1FCXLS37K-2A-SN-M4-HOA-PL 12/4FCXLS45K-1G-TM-M01-HOA-PL

25/30 200/23024 VAC 1

191 VA 17 VA 78-97 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 44 (20)FCXLS45K-1G-TM-M4-HOA-PL 12/4

FCXLS45K-1A-TM-M01-HOA-PL 120 VAC 1FCXLS45K-1A-TM-M4-HOA-PL 12/4FCXLS45K-2G-TM-M01-HOA-PL

60 46024 VAC 1

191 VA 17 VA 78-97 Amps 100A 20" x 16" x 8" (50.8 x 40.6 x 20.3) 44 (20)FCXLS45K-2G-TM-M4-HOA-PL 12/4

FCXLS45K-2A-TM-M01-HOA-PL 120 VAC 1FCXLS45K-2A-TM-M4-HOA-PL 12/4FCXLS55K-1G-TN-M01-HOA-PL

40 23024 VAC 1

191 VA 17 VA 90-110 Amps 200A 30" x 24" x 8" (76.2 x 61 x 20.3) 88 (40)FCXLS55K-1G-TN-M4-HOA-PL 12/4

FCXLS55K-1A-TN-M01-HOA-PL 120 VAC 1FCXLS55K-1A-TN-M4-HOA-PL 12/4FCXLS55K-2G-TN-M01-HOA-PL

75 46024 VAC 1

191 VA 17 VA 90-110 Amps 200A 30" x 24" x 8" (76.2 x 61 x 20.3) 88 (40)FCXLS55K-2G-TN-M4-HOA-PL 12/4

FCXLS55K-2A-TN-M01-HOA-PL 120 VAC 1FCXLS55K-2A-TN-M4-HOA-PL 12/4FCXLS75K-1G-TT-M01-HOA-PL

40/50 200/23024 VAC 1

400 VA 32 VA 140-190 Amps 200A 36" x 24" x 10"

(91.4 x 61 x 25.4) 124 (56.2)FCXLS75K-1G-TT-M4-HOA-PL 12/4FCXLS75K-1A-TT-M01-HOA-PL 120 VAC 1FCXLS75K-1A-TT-M4-HOA-PL 12/4FCXLS75K-2G-TT-M01-HOA-PL

100 46024 VAC 1

400 VA 32 VA 140-190 Amps 200A 36" x 24" x 10"

(91.4 x 61 x 25.4) 124 (56.2)FCXLS75K-2G-TT-M4-HOA-PL 12/4FCXLS75K-2A-TT-M01-HOA-PL 120 VAC 1FCXLS75K-2A-TT-M4-HOA-PL 12/4

Page 16: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

694

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

ORDERING INFORMATION - NFCXLS

Part Number HP Voltage Coil Voltage

Enclosure NEMA Rating

Coil Inrush

Coil Holding Current

Overload Range

Dimensions in (cm)

Weight lb (kg)

NFCXLS7K-1G-O-M01-HOA-PL

5 200/23024 VAC

1

45 VA 6 VA 14.5-18 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7)

NFCXLS7K-1G-O-M4-HOA-PL 12/4NFCXLS7K-1A-O-M01-HOA-PL

120 VAC1

NFCXLS7K-1A-O-M4-HOA-PL 12/4NFCXLS7K-2G-O-M01-HOA-PL

10 46024 VAC

1

45 VA 6 VA 14.5-18 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7)

NFCXLS7K-2G-O-M4-HOA-PL 12/4NFCXLS7K-2A-O-M01-HOA-PL

120 VAC1

NFCXLS7K-2A-O-M4-HOA-PL 12/4NFCXLS11K-1G-ON-M01-HOA-PL

7.5 23024 VAC

1

88 VA 9 VA 21-26 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7)NFCXLS11K-1G-ON-M4-HOA-PL 12/4NFCXLS11K-1A-ON-M01-HOA-PL

120 VAC1

NFCXLS11K-1A-ON-M4-HOA-PL 12/4NFCXLS11K-2G-ON-M01-HOA-PL

15 46024 VAC

1

88 VA 9 VA 21-26 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 17 (7.7)NFCXLS11K-2G-ON-M4-HOA-PL 12/4NFCXLS11K-2A-ON-M01-HOA-PL

120 VAC1

NFCXLS11K-2A-ON-M4-HOA-PL 12/4NFCXLS15K-1G-Q-M01-HOA-PL

10 20024 VAC

1

88 VA 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2)NFCXLS15K-1G-Q-M4-HOA-PL 12/4NFCXLS15K-1A-Q-M01-HOA-PL

120 VAC1

NFCXLS15K-1A-Q-M4-HOA-PL 12/4NFCXLS15K-2G-Q-M01-HOA-PL

10 23024 VAC

1

88 VA 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2)NFCXLS15K-2G-Q-M4-HOA-PL 12/4NFCXLS15K-2A-Q-M01-HOA-PL

120 VAC1

NFCXLS15K-2A-Q-M4-HOA-PL 12/4NFCXLS15K-3G-Q-M01-HOA-PL

20 46024 VAC

1

88 VA 9 VA 30-40 Amps 12" x 10" x 6" (30.5 x 25.4 x 15.2) 18 (8.2)NFCXLS15K-3G-Q-M4-HOA-PL 12/4NFCXLS15K-3A-Q-M01-HOA-PL

120 VAC1

NFCXLS15K-3A-Q-M4-HOA-PL 12/4NFCXLS22K-1G-RN-M01-HOA-PL

15 200/23024 VAC

1

191 VA 17 VA 54-65 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)NFCXLS22K-1G-RN-M4-HOA-PL 12/4NFCXLS22K-1A-RN-M01-HOA-PL

120 VAC1

NFCXLS22K-1A-RN-M4-HOA-PL 12/4NFCXLS22K-2G-QN-M01-HOA-PL

30 46024 VAC

1

191 VA 17 VA 42-55 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 27 (12.2)NFCXLS22K-2G-QN-M4-HOA-PL 12/4NFCXLS22K-2A-QN-M01-HOA-PL

120 VAC1

NFCXLS22K-2A-QN-M4-HOA-PL 12/4NFCXLS37K-1G-SN-M01-HOA-PL

20/25 200/23024 VAC

1

191 VA 17 VA 64-82 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 28 (12.7)NFCXLS37K-1G-SN-M4-HOA-PL 12/4NFCXLS37K-1A-SN-M01-HOA-PL

120 VAC1

NFCXLS37K-1A-SN-M4-HOA-PL 12/4NFCXLS37K-2G-SN-M01-HOA-PL

50 46024 VAC

1

191 VA 17 VA 64-82 Amps 16" x 12" x 8" (40.6 x 30.5 x 20.3) 28 (12.7)NFCXLS37K-2G-SN-M4-HOA-PL 12/4NFCXLS37K-2A-SN-M01-HOA-PL

120 VAC1

NFCXLS37K-2A-SN-M4-HOA-PL 12/4NFCXLS45K-1G-TM-M01-HOA-PL

25/30 200/230 24 VAC120 VAC

1

191 VA 17 VA 78-97 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 38 (17.2)NFCXLS45K-1G-TM-M4-HOA-PL 12/4NFCXLS45K-1A-TM-M01-HOA-PL 1NFCXLS45K-1A-TM-M4-HOA-PL 12/4NFCXLS45K-2G-TM-M01-HOA-PL

60 46024 VAC

1

191 VA 17 VA 78-97 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 38 (17.2)NFCXLS45K-2G-TM-M4-HOA-PL 12/4NFCXLS45K-2A-TM-M01-HOA-PL

120 VAC1

NFCXLS45K-2A-TM-M4-HOA-PL 12/4NFCXLS55K-1G-TN-M01-HOA-PL

40 23024 VAC

1

191 VA 17 VA 90-110 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 40 (18.1)

NFCXLS55K-1G-TN-M4-HOA-PL 12/4NFCXLS55K-1A-TN-M01-HOA-PL

120 VAC1

NFCXLS55K-1A-TN-M4-HOA-PL 12/4NFCXLS55K-2G-TN-M01-HOA-PL

75 46024 VAC

1

191 VA 17 VA 90-110 Amps 20" x 16" x 8" (50.8 x 40.6 x 20.3) 40 (18.1)

NFCXLS55K-2G-TN-M4-HOA-PL 12/4NFCXLS55K-2A-TN-M01-HOA-PL

120 VAC1

NFCXLS55K-2A-TN-M4-HOA-PL 12/4NFCXLS75K-1G-TT-M01-HOA-PL

40/50 200/23024 VAC

1

400 VA 32 VA 140-190 Amps 24" x 20" x 8" (60.1 x 50.8 x 20.3) 65 (29.4)

NFCXLS75K-1G-TT-M4-HOA-PL 12/4NFCXLS75K-1A-TT-M01-HOA-PL

120 VAC1

NFCXLS75K-1A-TT-M4-HOA-PL 12/4NFCXLS75K-2G-TT-M01-HOA-PL

100 46024 VAC

1

400 VA 32 VA 140-190 Amps 24" x 20" x 8" (60.1 x 50.8 x 20.3) 65 (29.4)

NFCXLS75K-2G-TT-M4-HOA-PL 12/4NFCXLS75K-2A-TT-M01-HOA-PL

120 VAC1

NFCXLS75K-2A-TT-M4-HOA-PL 12/4

FUSIBLE AND NON-FUSIBLE MOTOR STARTERSFCXLS, NFCXLS SERIES

Page 17: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

695

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

Supply Voltage Model specific, 3 phase, 60 Hz, 380-480 VAC or 200-240 VAC

Motor Rating 0 .75 to 250 HpFrequency Range 0-320 HzAcceleration Time 0 .1 - 3000 secondsDeceleration Time 0 .1 - 3000 secondsDigital Input 6 logical, 24 VDC= on, 0 VDC= off,

all configurableAnalog Input 2; 0-010v or 4-20 mA voltage Input impedance 200Ω k Current impedance 250ΩDigital Output Open collector, max . load

48V/ 50 mAAnalog Output 1; 0-10 VDC or 4-20 mA

programmable 500Ω maximum load

Relay Outputs 2; SPDT 8A at 24VDC or 250 VAC 0 .4A at 125 VDC minimum load 10mA at 5 VAC/VDCFilter Type 5% DC choke (Frame D and E

standard; 3% built in) -- Optional for frames A, B, C

Class 2 GMC/ RFIEMC Complies with EN50082-1, -2 EN61800-3Communication Protocol RS485 MODBUS, BACnetOperating Humidity 0 to 90% RH, non-condensingOperating Temperature 14° to 104°F (-10° to 40°C)Approvals UL Listed File E190898, CE, RoHSEco Friendly YesWarranty 3 years

HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD

DESCRIPTION

CORE VFDs are an economical option drive option with easy to set up functionality . The firmware includes special features that make start-up and commissioning of HVAC applications especially easy . The Wizard consists of critical commissioning questions to intuitively guide users through parameter setup process, which covers nearly all your commercial heating, ventilation and air conditioning (HVAC) applications . Additionally, the VFD CORE is rated for constant torque for industrial applications . The CORE VFD line is also available with a bypass option which is also easy to integrate . The by-pass comes with a control transformer, time delay fuses, 3 contactors, primary and secondary fuses . The CORE line of VFDs is a time saver as well as an energy saver .

FEATURES

• Intuitive commissioning• Start-up wizard• Real-time clock• Detachable keypad• PID with sleep control

SPECIFICATIONS

HCRDA005DA1000T

DIMENSIONS AND WEIGHTS

Frame 208/230 VAC 460 VACEnclosure NEMA type

Width in (cm)

Height in (cm)

Depth in (cm)

Weight lb (kg)

A 1.0 - 7.5 HP 1.0 - 10 HP NEMA 1 5.12 (13.0) 9.84 (25.0) 6.69 (17.0) 6.17 (2.8)

B 10 - 15 HP 15 HP NEMA 1 7.48 (19.0) 12.6 (32.0) 7.48 (19.0) 10.14 (4.6)

B 20 HP 20 - 25 HP NEMA 1 7.48 (19.0) 12.6 (32.0) 7.48 (19.0) 12.35 (5.6)

C 25 - 40 HP NEMA 1 9.84 (25.0) 15.75 (40.0) 8.27 (21.0) 23.15 (10.5)

C 30 - 40 HP NEMA 1 9.84 (25.0) 15.75 (40.0) 8.27 (21.0) 19.18 (8.7)

C 50 HP NEMA 1 9.84 (25.0) 15.75 (40.0) 8.27 (21.0) 20.72 (9.4)

D 50 - 60 HP 60 - 75 HP NEMA 1 12.99 (33.0) 27.10 (68.83) 10.83 (27.5) 78.26 (35.5)

D 100 - 125 HP NEMA 1 12.99 (33.0) 27.10 (68.83) 10.83 (27.5) 89.29 (40.5)

E 75 HP NEMA 1 14.57 (37.0) 28.18 (71.58) 11.81 (30.0) 100.75 (45.7)

E 100 HP NEMA 1 14.57 (37.0) 28.18 (71.58) 11.81 (30.0) 101.85 (46.2)

E 125 HP NEMA 1 14.57 (37.0) 28.18 (71.58) 11.81 (30.0) 120.59 (54.7)

Page 18: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

696

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Frame Sizes A, B, and C

R(L1)

S(L2)

T(L3)

FWD

R(L1)

S(L2)

T(L3)

NFB U(T1)

V(T2)

W(T3)

MOTOR

JUMPER

DC CHOKE(OPTIONAL) BREAKING RESISTOR

(OPTIONAL)

IM3~

REVMI1

FWD/STOPREV/STOP

3-PHASE POWER IS PROVIDED

FUSE/NO FUSE BREAKER

FACTORY SETTING:PNP SOURCE

PRESET SPD 1PRESET SPD 2PRESET SPD3

PRESET SPD 4EXT FAULTFAULT RESET

NANA

MI3MI2

MI4MI5MI6MI7MI8

MULTI-FUNCTIONOUTPUT TERMINALS

RA1

RB1

RC1

RA2

RC2

RA3

RC3

250VAC/6A

30VDC/6A

30VDC/5A

MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A

MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A

30VDC/5ADCM

SCM

S1

DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE

FACTORY SETTING

POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP

DIGITAL SIGNAL COMMON TERMINAL

+10V/20mA

0~10V/0~20mA

0-20mA/0~10V

ANALOG SIGNALCOMMON TERMINAL

3 21

5KΩ

MAIN CIRCUIT (POWER) TERMINALS

CONTROL TERMINALS

SHIELDED LEADS & CABLES

+10V

AVI1

ACI

AVI2 ACM

AFM1

ACM

AFM2ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA

ANALOG SIGNAL COMMON TERMINAL

ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA

OPTION SLOT 1

OPTION SLOT 3

COMMUNICATION EXTENSION CARD

I/O & RELAY EXTENSION CARD8 18 1MODBUS RS-485PIN 1~2, 7, 8: RESERVEDPIN 3, 6: GNDPIN 4: SG-PIN 5: SG+

SG+

SG-

0~+10V

COM

DCM

+24V

RA1 (RELAY OUT 1): RUNRA2 (RELAY OUT 2): FAULTRA3 (RELAY OUT 3): READY

MI: MULTIFUNCTION INPUTAVI: ANALOG VOLTAGE INPUTACI: ANALOG CURRENT INPUT

+24V

Frame Sizes D and E

FWD

U(T1)

V(T2)

W(T3)

MOTOR

IM3~

REVMI1

FWD/STOPREV/STOP

3-PHASE POWER IS PROVIDED

R(L1)

S(L2)

T(L3)

R(L1)

S(L2)

T(L3)

NFB

FUSE/NO FUSE BREAKER

FACTORY SETTING:PNP SOURCE

PRESET SPD 1PRESET SPD 2PRESET SPD 3

PRESET SPD 4EXT FAULTFAULT RESET

NANA

MI3MI2

MI4MI5MI6MI7MI8

MULTI-FUNCTIONOUTPUT TERMINALS

RA1

RB1

RC1

RA2

RC2

RA3

RC3

250VAC/6A

30VDC/6A

30VDC/5A

250VAC/5A

MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A

MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 30VDC/5A

DCM

SCM

S1

DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE

FACTORY SETTING

POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP

DIGITAL SIGNAL COMMON TERMINAL

+10V/20mA

0~10V/0~20mA

0-20mA/0~10V

ANALOG SIGNALCOMMON TERMINAL

3 21

5KΩ

MAIN CIRCUIT (POWER) TERMINALS

CONTROL TERMINALS

SHIELDED LEADS & CABLES

+10V

AVI1

ACI

AVI2 ACM

AFM1

ACM

AFM2ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA

ANALOG SIGNAL COMMON TERMINAL

ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA

OPTION SLOT 1

OPTION SLOT 3

COMMUNICATION EXTENSION CARD

I/O & RELAY EXTENSION CARD8 18 1MODBUS RS-485PIN 1~2, 7, 8: RESERVEDPIN 3, 6: GNDPIN 4: SG-PIN 5: SG+

SG+

SG-

0~+10V

COM

DCM

+24V

+1/DC+ -/DC+

r

s

R

S

FRAME E

RA1 (RELAY OUT 1): RUNRA2 (RELAY OUT 2): FAULTRA3 (RELAY OUT 3): READY

MI: MULTIFUNCTION INPUTAVI: ANALOG VOLTAGE INPUTACI: ANALOG CURRENT INPUT

+24V

Source Mode with internal power (+24 VDC)

M1

M2

M8

+24V

DCM

COM

INTERNAL CIRCUIT

WIRING

HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD

Page 19: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

697

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

ORDERING INFORMATION

MODEL DESCRIPTIONHCRDA0020A1000T Core VFD 230 V, 2 HP, NEMA 1HCRDA0030A1000T Core VFD 230 V, 3 HP, NEMA 1HCRDA0050A1000T Core VFD 230 V, 5 HP, NEMA 1HCRDA0075A1000T Core VFD 230 V, 7.5 HP, NEMA 1HCRDA0100B1000T Core VFD 230 V, 10 HP, NEMA 1HCRDA0150B1000T Core VFD 230 V, 15 HP, NEMA 1HCRDA0200B1000T Core VFD 230 V, 20 HP, NEMA 1HCRDA0250C1000T Core VFD 230 V, 25 HP, NEMA 1HCRDA0300C1000T Core VFD 230 V, 30 HP, NEMA 1HCRDA0400C1000T Core VFD 230 V, 40 HP, NEMA 1HCRDA0500D1000T Core VFD 230 V, 50 HP, NEMA 1HCRDA0600D1000T Core VFD 230 V, 60 HP, NEMA 1HCRDA0750E1000T Core VFD 230 V, 75 HP, NEMA 1HCRDA1000E1000T Core VFD 230 V, 100 HP, NEMA 1HCRDA1250E1000T Core VFD 230 V, 125 HP, NEMA 1HCRDC0010A1000T Core VFD 460 V, 1 HP, NEMA 1HCRDC0020A1000T Core VFD 460 V, 2 HP, NEMA 1HCRDC0030A1000T Core VFD 460 V, 3 HP, NEMA 1HCRDC0050A1000T Core VFD 460 V, 5 HP, NEMA 1HCRDC0075A1000T Core VFD 460 V, 7.5 HP, NEMA 1HCRDC0100A1000T Core VFD 460 V, 10 HP, NEMA 1HCRDC0150B1000T Core VFD 460 V, 15 HP, NEMA 1HCRDC0200B1000T Core VFD 460 V, 20 HP, NEMA 1HCRDC0250B1000T Core VFD 460 V, 25 HP, NEMA 1HCRDC0300C1000T Core VFD 460 V, 30 HP, NEMA 1HCRDC0400C1000T Core VFD 460 V, 40 HP, NEMA 1HCRDC0500C1000T Core VFD 460 V, 50 HP, NEMA 1HCRDC0600D1000T Core VFD 460 V, 60 HP, NEMA 1HCRDC0750D1000T Core VFD 460 V, 75 HP, NEMA 1HCRDC1000D1000T Core VFD 460 V, 100 HP, NEMA 1HCRDC1250D1000T Core VFD 460 V, 125 HP, NEMA 1HCRDA0010A1000T Core VFD 230 V, 1 HP, NEMA 1

HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD

Page 20: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

698

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Supply Voltage Model specific, 3 phase, 60 Hz, 380-480 VAC or 200-240 VAC

Motor Rating 0 .75 to 250 HpFrequency Range 0-320 HzAcceleration Time 0 .1 - 3000 secondsDeceleration Time 0 .1 - 3000 secondsDigital Inputs 6 logical, 24 VDC = on, 0 VDC = off,

all configurableAnalog Input 2; 0-010V or 4-20 mA voltageInput Impedance 200Ω kCurrent Impedance 250ΩDigital Output Open collector, max . load 48V/ 50

mAAnalog Output 1; 0-10 VDC or 4-20 mA

programmable 500Ω maximum load

Relay Outputs 2; SPDT 8A at 24VDC or 250 VAC 0 .4A at 125 VDC minimum load 10mA at 5 VAC/VDCFilter Type 5% DC choke optional on frames

A, B, and CClass 2 GMC/ RFIEMC Complies with EN50082-1, -2 EN61800-3Communication Protocol RS485 MODBUS, BACnetOperating Humidity 0 to 90% RH, non-condensingOperating Temperature 14° to 104°F (-10° to 40°C)Approvals UL Listed File #E190898, CE, RoHSEco Friendly YesWarranty 3 years

HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD WITH BYPASS

DESCRIPTION

The CORE VFD with a bypass option comes with a control transformer, time delay fuses, three contactors, primary and secondary fuses . CORE VFDs are an economical option drive option with easy to set up functionality . The firmware includes special features that make start-up and commissioning of HVAC applications especially easy . The Wizard consists of critical commissioning questions to intuitively guide users through a parameter setup process, which covers nearly all your commercial heating, ventilation and air conditioning (HVAC) applications . Additionally, the VFD CORE is rated for constant torque for industrial applications . The CORE line of VFDs is a time saver as well as an energy saver .

FEATURES

• Intuitive commissioning• Start-up wizard• Real-time clock• Detachable keypad• PID with sleep control

SPECIFICATIONS

Core VFD with Bypass

DIMENSIONS AND WEIGHTS

Frame 208/230 VAC 460 VACEnclosure NEMA type

Width in (cm)

Height in (cm)

Depth in (cm)

Weight lb (kg)

A 1.0 - 7.5 HP 1.0 - 10 HP NEMA 1 8.9 (22.7) 22.0 (55.9) 9.3 (23.6) 37.0 (16.78)

B 10 - 20 HP 15 - 25 HP NEMA 1 12.4 (31.6) 48.0 (121.9) 9.66 (24.5) 67.0(30.39)

C 25 - 40 hp 30 - 50 HP NEMA 1 12.4 (31.6) 48.0 (121.9) 9.66 (24.5) 83.0 (37.65)

D 50 - 60 HP 60 - 125 HP NEMA 1 19.5 (49.7) 53.5 (135.9) 11.4 (29.1) 193.0 (87.54)

E 75 - 125 HP NEMA 1 23.0 (48.3) 66.5 (168.9) 14.4 (36.7) 225 (102.06)

Page 21: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

699

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

Frame Sizes A, B, and C

R(L1)

S(L2)

T(L3)

FWD

R(L1)

S(L2)

T(L3)

NFB U(T1)

V(T2)

W(T3)

MOTOR

JUMPER

DC CHOKE(OPTIONAL) BREAKING RESISTOR

(OPTIONAL)

IM3~

REVMI1

FWD/STOPREV/STOP

3-PHASE POWER IS PROVIDED

FUSE/NO FUSE BREAKER

FACTORY SETTING:PNP SOURCE

PRESET SPD 1PRESET SPD 2PRESET SPD3

PRESET SPD 4EXT FAULTFAULT RESET

NANA

MI3MI2

MI4MI5MI6MI7MI8

MULTI-FUNCTIONOUTPUT TERMINALS

RA1

RB1

RC1

RA2

RC2

RA3

RC3

250VAC/6A

30VDC/6A

30VDC/5A

MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A

MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A

30VDC/5ADCM

SCM

S1

DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE

FACTORY SETTING

POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP

DIGITAL SIGNAL COMMON TERMINAL

+10V/20mA

0~10V/0~20mA

0-20mA/0~10V

ANALOG SIGNALCOMMON TERMINAL

3 21

5KΩ

MAIN CIRCUIT (POWER) TERMINALS

CONTROL TERMINALS

SHIELDED LEADS & CABLES

+10V

AVI1

ACI

AVI2 ACM

AFM1

ACM

AFM2ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA

ANALOG SIGNAL COMMON TERMINAL

ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA

OPTION SLOT 1

OPTION SLOT 3

COMMUNICATION EXTENSION CARD

I/O & RELAY EXTENSION CARD8 18 1MODBUS RS-485PIN 1~2, 7, 8: RESERVEDPIN 3, 6: GNDPIN 4: SG-PIN 5: SG+

SG+

SG-

0~+10V

COM

DCM

+24V

RA1 (RELAY OUT 1): RUNRA2 (RELAY OUT 2): FAULTRA3 (RELAY OUT 3): READY

MI: MULTIFUNCTION INPUTAVI: ANALOG VOLTAGE INPUTACI: ANALOG CURRENT INPUT

+24V

WIRING

HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD WITH BYPASS

Page 22: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

700

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Frame Sizes D and E

FWD

U(T1)

V(T2)

W(T3)

MOTOR

IM3~

REVMI1

FWD/STOPREV/STOP

3-PHASE POWER IS PROVIDED

R(L1)

S(L2)

T(L3)

R(L1)

S(L2)

T(L3)

NFB

FUSE/NO FUSE BREAKER

FACTORY SETTING:PNP SOURCE

PRESET SPD 1PRESET SPD 2PRESET SPD 3

PRESET SPD 4EXT FAULTFAULT RESET

NANA

MI3MI2

MI4MI5MI6MI7MI8

MULTI-FUNCTIONOUTPUT TERMINALS

RA1

RB1

RC1

RA2

RC2

RA3

RC3

250VAC/6A

30VDC/6A

30VDC/5A

250VAC/5A

MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 250VAC/5A

MULTI-FUNCTION OUTPUT FREQUENCY TERMINALS 30VDC/5A

DCM

SCM

S1

DIGITAL SIGNAL COMMON TERMINAL WHILE USING INTERNAL POWER TO RUN SINK MODE

FACTORY SETTING

POWER REMOVAL SAFETY FUNCTION FOR EMERGENCY STOP

DIGITAL SIGNAL COMMON TERMINAL

+10V/20mA

0~10V/0~20mA

0-20mA/0~10V

ANALOG SIGNALCOMMON TERMINAL

3 21

5KΩ

MAIN CIRCUIT (POWER) TERMINALS

CONTROL TERMINALS

SHIELDED LEADS & CABLES

+10V

AVI1

ACI

AVI2 ACM

AFM1

ACM

AFM2ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA

ANALOG SIGNAL COMMON TERMINAL

ANALOG MULTI-FUNCTION OUTPUT TERMINAL 0~10V/0~20mA

OPTION SLOT 1

OPTION SLOT 3

COMMUNICATION EXTENSION CARD

I/O & RELAY EXTENSION CARD8 18 1MODBUS RS-485PIN 1~2, 7, 8: RESERVEDPIN 3, 6: GNDPIN 4: SG-PIN 5: SG+

SG+

SG-

0~+10V

COM

DCM

+24V

+1/DC+ -/DC+

r

s

R

S

FRAME E

RA1 (RELAY OUT 1): RUNRA2 (RELAY OUT 2): FAULTRA3 (RELAY OUT 3): READY

MI: MULTIFUNCTION INPUTAVI: ANALOG VOLTAGE INPUTACI: ANALOG CURRENT INPUT

+24V

WIRING (continued)

HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD WITH BYPASS

Page 23: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

701

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

ORDERING INFORMATION

MODEL DESCRIPTIONHCRBA0010A1300T CORE VFD W/BYPASS/208V/1 HP/NEMA 1HCRBA0020A1300T CORE VFD W/BYPASS/208V/2HP/NEMA 1/FRAHCRBA0030A1300T CORE VFD W/BYPASS/208V/3HP/NEMA 1/FRAHCRBA0050A1300T CORE VFD W/BYPASS/208V/5HP/NEMA 1/FRAHCRBA0075A1300T CORE VFD W/BYPASS/208V/7.5HP/NEMA 1/FRAHCRBA0100B1300T CORE VFD W/BYPASS/208V/10HP/NEMA 1/FRBHCRBA0150B1300T CORE VFD W/BYPASS/208V/15HP/NEMA 1/FRBHCRBA0200B1300T CORE VFD W/BYPASS/208V/20HP/NEMA 1/FRBHCRBA0250C1300T CORE VFD W/BYPASS/208V/25HP/NEMA 1/FRCHCRBA0300C1300T CORE VFD W/BYPASS/208V/30HP/NEMA 1/FRCHCRBA0400C1300T CORE VFD W/BYPASS/208V/40HP/NEMA 1/FRCHCRBA0500D1300T CORE VFD W/BYPASS/208V/50HP/NEMA 1/FRDHCRBA0600D1300T CORE VFD W/BYPASS/208V/60HP/NEMA 1/FRDHCRBA0750E1300T CORE VFD W/BYPASS/208V/75HP/NEMA 1/FREHCRBA1000E1300T CORE VFD W/BYPASS/208V/100HP/NEMA 1/FREHCRBA1250E1300T CORE VFD W/BYPASS/208V/125HP/NEMA 1/FREHCRBB0010A1300T CORE VFD W/BYPASS/230V/1HP/NEMA 1/FRAHCRBB0020A1300T CORE VFD W/BYPASS/230V/2HP/NEMA 1/FRAHCRBB0030A1300T CORE VFD W/BYPASS/230V/3HP/NEMA 1/FRAHCRBB0050A1300T CORE VFD W/BYPASS/230V/5HP/NEMA 1/FRAHCRBB0075A1300T CORE VFD W/BYPASS/230V/7.5HP/NEMA 1/FRAHCRBB0100B1300T CORE VFD W/BYPASS/230V/10HP/NEMA 1/FRBHCRBB0150B1300T CORE VFD W/BYPASS/230V/15HP/NEMA 1/FRBHCRBB0200B1300T CORE VFD W/BYPASS/230V/20HP/NEMA 1/FRB

MODEL DESCRIPTIONHCRBB0250C1300T CORE VFD W/BYPASS/230V/25HP/NEMA 1/FRCHCRBB0300C1300T CORE VFD W/BYPASS/230V/30HP/NEMA 1/FRCHCRBB0400C1300T CORE VFD W/BYPASS/230V/40HP/NEMA 1/FRCHCRBB0500D1300T CORE VFD W/BYPASS/230V/50HP/NEMA 1/FRDHCRBB0600D1300T CORE VFD W/BYPASS/230V/60HP/NEMA 1/FRDHCRBB0750E1300T CORE VFD W/BYPASS/230V/75HP/NEMA 1/FREHCRBB1000E1300T CORE VFD W/BYPASS/230V/100HP/NEMA 1/FREHCRBB1250E1300T CORE VFD W/BYPASS/230V/125HP/NEMA 1/FREHCRBC0010A1300T CORE VFD W/BYPASS/460V/1HP/NEMA 1/FRAHCRBC0020A1300T CORE VFD W/BYPASS/460V/2HP/NEMA 1/FRAHCRBC0030A1300T CORE VFD W/BYPASS/460V/3HP/NEMA 1/FRAHCRBC0050A1300T CORE VFD W/BYPASS/460V/5HP/NEMA 1/FRAHCRBC0075A1300T CORE VFD W/BYPASS/460V/7.5HP/NEMA 1/FRAHCRBC0100A1300T CORE VFD W/BYPASS/460V/10HP/NEMA 1/FRAHCRBC0150B1300T CORE VFD W/BYPASS/460V/15HP/NEMA 1/FRBHCRBC0200B1300T CORE VFD W/BYPASS/460V/20HP/NEMA 1/FRBHCRBC0250B1300T CORE VFD W/BYPASS/460V/25HP/NEMA 1/FRBHCRBC0300C1300T CORE VFD W/BYPASS/460V/30HP/NEMA 1/FRCHCRBC0400C1300T CORE VFD W/BYPASS/460V/40HP/NEMA 1/FRCHCRBC0500C1300T CORE VFD W/BYPASS/460V/50HP/NEMA 1/FRCHCRBC0600D1300T CORE VFD W/BYPASS/460V/60HP/NEMA 1/FRDHCRBC0750D1300T CORE VFD W/BYPASS/460V/75HP/NEMA 1/FRDHCRBC1000D1300T CORE VFD W/BYPASS/460V/100HP/NEMA 1/FRDHCRBC1250D1300T CORE VFD W/BYPASS/460V/125HP/NEMA 1/FRD

Transformer

Three bypass contactorsshown (BC-1, BC-2, BC-3).BC-3 not supplied in a twocontactor bypass

M

HVFDSB3

Main Disconnect

L1

L2

L3

UVW

L1

L2

L3

BC-3 BC-1

BC-2

To factory wired bypass controls (switches, coils, etc.)

Note: Typical wiring shown. Refer to product installation manual for electrical wiring connections and requirements.

WIRING (continued)

HONEYWELL VARIABLE FREQUENCY DRIVESCORE VFD WITH BYPASS

Page 24: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

702

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Supply Voltage 208 to 230 VAC, 1 phase input - 3 phase output

380 to 480 VAC, 3 phase input/ output

Motor Rating 0 .25 - 7 .5 hpAcceleration Time 0 .1- 3000 secondsDeceleration Time 0 .1 - 3000 secondsFrequency Range 30 - 320 HzDigital Switch Inputs 6; 0 - 30 VDC programmableAnalog Inputs 2; (1) 0-10 VDC, (1) 0-20 mA or

4-20 mADigital Outputs 1 Open Collector, max . load 48V/

50mAAnalog Output 1, 0-20 mA or 4-20 mA, RL=500ΩRelay Outputs 2; (1) SPST N .O . (1) SPDT 250

VAC/2A, 250 VDC/0 .4A

Filter Type RFICommunication Protocol

RS485 (Modbus protocol), SerialOperating Humidity 0 to 90% RH (non-condensing)Operating Temperature 14° to 122°F (-10° to 50°C)Frame Size MI1, MI2, MI3Dimensions Frame sizes MI1 6 .1"H x 2 .6"W x 3 .9"D

(15 .5 x 6 .6 x 9 .9 cm) MI2 7 .7"H x 3 .5"W x 4 .0"D

(19 .6 x 8 .9 x 10 .2 cm) MI3 10 .3"D x3 .9"W x 4 .3"D

(26 .2 x 9 .9 x 10 .9 cm)Weights MI1 1 .20 lb (0 .55 kg) MI2 1 .50 lb (0 .65 kg) MI3 2 .18 lb (0 .99 kg)Approvals CE, UL, cUL FILE #E190898Warranty 3 years

HONEYWELL COMPACT VARIABLE FREQUENCY DRIVESMARTDRIVE COMPACT VFD

DESCRIPTIONThis compact VFD is a true micro drive, which saves space in the equipment cabinet and makes installation easy . The SmartDrive architecture allows for ease and speed in drive configuration . The intuitive user interface makes commissioning a breeze . The SmartDrive Compact VFD provides a standard PI Controller . Choose options to fit any application . Interface type, filter, enclosure, inputs, and outputs are available in a wide array of combinations . For wall mounting, a frame kit is recommended . Frame kits are not necessary for installation inside a panel .

FEATURES• Small, compact micro drive design• PI controller standard• No main power supply required for programming• Intuitive user interface• DIN rail or screw mounting• Flexible options include inputs, outputs, field bus, and

filtering• Application interface "touch wheel" makes

programming easy

SPECIFICATIONS

Terminal Signal Factory preset Description

1 +10Vre Ref. voltage out Maximum load 10 mA2 AI1 Analog signal in 1 Freq. reference P)

0 - +10 V Ri = 200 kΩ (min)

3 GND I/O signal ground6 24Vout 24V output for DI's

±20%, max. load 50 mA

7 GND I/O signal ground8 DI1 Digital input 1 Start forward P) 0 - +30 V Ri = 12 kΩ min9 DI2 Digital input 2 Start reverse P) 10 DI3 Digital input 3 Preset speed B0 P) A A RS485 signal A FB CommunicationB B RS485 signal B FB Communication4 AI2 Analog signal in 2 PI actual value P) 0(4) - 20 mA, Ri = 200Ω5 GND I/O signal ground13 GND I/O signal ground14 DI4 Digital input 4 Preset speed B1P) 0 - +30 V Ri = 12 kΩ (min)15 DI5 Digital input 5 Fault reset P)

16 DI6 Digital input 6 Disable PI contr. P)

18 AO Output frequency P) 0(4) - 20 mA, RL = 500Ω20 DO Digital signal out Active = READY P) Open collector, max. load

48V/50mA22 RO 11 Relay out 1 Active = RUN P) Max. switching load:

250 VAC/2A or 250 VDC/0.4A

23 RO 12

24 RO 21 Relay out 2 Active = FAULT P) Max. switching load:250 VAC/2A or 250 VDC/0.4A

25 RO 2226 RO 23

P) = Programmable function, see parameter lists and descriptions in installation manual.

mA

API FULL

Note: NEMA 1 frame kits include the top protection from vertically dripping water with additional physical contact protection over the wiring terminals . Recommended for non-enclosed VFD mounting .

CONTROL I/O

Page 25: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

703

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

HONEYWELL COMPACT VARIABLE FREQUENCY DRIVESMARTDRIVE COMPACT VFD

ORDERING INFORMATION

Full IO Model Limited IO Model Supply Voltage Current Rating

Horsepower EMCFrame Size

HVFDCD1B0003F00 HVFDCD1B0003L00 208 to 230 VAC, 1 phase input - 3 phase output 1.7A 0.25 NO MI1

HVFDCD1B0003F01 HVFDCD1B0003L01 208 to 230 VAC, 1 phase input - 3 phase output 1.7A 0.25 YES MI1

HVFDCD1B0005F00 HVFDCD1B0005L00 208 to 230 VAC, 1 phase input - 3 phase output 2.4A 0.5 NO MI1

HVFDCD1B0005F01 HVFDCD1B0005L01 208 to 230 VAC, 1 phase input - 3 phase output 2.4A 0.5 YES MI1

HVFDCD1B0007F00 HVFDCD1B0007L00 208 to 230 VAC, 1 phase input - 3 phase output 2.8A 0.75 NO MI1

HVFDCD1B0007F01 HVFDCD1B0007L01 208 to 230 VAC, 1 phase input - 3 phase output 2.8A 0.75 YES MI1

HVFDCD1B0010F00 HVFDCD1B0010L00 208 to 230 VAC, 1 phase input - 3 phase output 3.7A 1 NO MI1

HVFDCD1B0010F01 HVFDCD1B0010L01 208 to 230 VAC, 1 phase input - 3 phase output 3.7A 1 YES MI1

HVFDCD1B0015F00 HVFDCD1B0015L00 208 to 230 VAC, 1 phase input - 3 phase output 4.8A 1.5 NO MI2

HVFDCD1B0015F01 HVFDCD1B0015L01 208 to 230 VAC, 1 phase input - 3 phase output 4.8A 1.5 YES MI2

HVFDCD1B0020F00 HVFDCD1B0020L00 208 to 230 VAC, 1 phase input - 3 phase output 7.0A 2 NO MI2

HVFDCD1B0020F01 HVFDCD1B0020L01 208 to 230 VAC, 1 phase input - 3 phase output 7.0A 2 YES MI2

HVFDCD1B0030F00 HVFDCD1B0030L00 208 to 230 VAC, 1 phase input - 3 phase output 11.0A 3 NO MI3

HVFDCD1B0030F01 HVFDCD1B0030L01 208 to 230 VAC, 1 phase input - 3 phase output 11.0A 3 YES MI3

HVFDCD3C0005F00 HVFDCD3C0005L00 380 to 480 VAC, 3 phase input/ output 1.3A 0.5 NO MI1

HVFDCD3C0005F01 HVFDCD3C0005L01 380 to 480 VAC, 3 phase input/ output 1.3A 0.5 YES MI1

HVFDCD3C0007F00 HVFDCD3C0007L00 380 to 480 VAC, 3 phase input/ output 1.9A 0.75 NO MI1

HVFDCD3C0007F01 HVFDCD3C0007L01 380 to 480 VAC, 3 phase input/ output 1.9A 0.75 YES MI1

HVFDCD3C0010F00 HVFDCD3C0010L00 380 to 480 VAC, 3 phase input/ output 2.4A 1 NO MI1

HVFDCD3C0010F01 HVFDCD3C0010L01 380 to 480 VAC, 3 phase input/ output 2.4A 1 YES MI1

HVFDCD3C0015F00 HVFDCD3C0015L00 380 to 480 VAC, 3 phase input/ output 3.3A 1.5 NO MI1

HVFDCD3C0015F01 HVFDCD3C0015L01 380 to 480 VAC, 3 phase input/ output 3.3A 1.5 YES MI1

HVFDCD3C0020F00 HVFDCD3C0020L00 380 to 480 VAC, 3 phase input/ output 4.3A 2 NO MI2

HVFDCD3C0020F01 HVFDCD3C0020L01 380 to 480 VAC, 3 phase input/ output 4.3A 2 YES MI2

HVFDCD3C0030F00 HVFDCD3C0030L00 380 to 480 VAC, 3 phase input/ output 5.6A 3 NO MI2

HVFDCD3C0030F01 HVFDCD3C0030L01 380 to 480 VAC, 3 phase input/ output 5.6A 3 YES MI2

HVFDCD3C0040F00 HVFDCD3C0040L00 380 to 480 VAC, 3 phase input/ output 7.6A 4 NO MI3

HVFDCD3C0040F01 HVFDCD3C0040L01 460 to 480 VAC, 3 phase input/ output 7.6A 4 YES MI3

HVFDCD3C0050F00 HVFDCD3C0050L00 460 to 480 VAC, 3 phase input/ output 9.0A 5 NO MI3

HVFDCD3C0050F01 HVFDCD3C0050L01 460 to 480 VAC, 3 phase input/ output 9.0A 5 YES MI3

HVFDCD3C0075F00 HVFDCD3C0075L00 460 to 480 VAC, 3 phase input/ output 12.0A 7.5 NO MI3

HVFDCD3C0075F01 HVFDCD3C0075L01 460 to 480 VAC, 3 phase input/ output 12.0A 7.5 YES MI3

ACCESSORIESHVFDCABLE Commissioning cable and USB adaptorHVFDCDMCA VFD commissioning deviceHVFDCDMCAKIT Commisioning kitHVFDCDNEMA1FR1 Enclosure upgrade Nema 1 kit frame size1HVFDCDNEMA1FR2 Enclosure upgrade Nema 1 kit frame size2HVFDCDNEMA1FR3 Enclosure upgrade Nema 1 kit frame size3

Page 26: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

704

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVESSMARTVFD HVAC

Supply Voltage Model specific, 3 phase, 60 Hz, 380-480 VAC or 200-240 VAC

Motor Rating 0 .75 to 250 HpFrequency Range 0-320 HzAcceleration Time 0 .1 - 3000 secondsDeceleration Time 0 .1 - 3000 secondsDigital Inputs 6 logical, 24 VDC= on, 0 VDC= off,

all configurableAnalog Input 2; 0-10V or 4-20 mA voltage input impedance 200Ω k current impedance 250ΩDigital Output Open collector,

max . load 48V/ 50 mAAnalog Output 1; 0-10 VDC or 4-20 mA

programmable 500Ω maximum loadRelay Outputs 2; SPDT 8A at 24 VDC or 250 VAC 0 .4A at 125 VDC minimum load 10mA at 5 VAC/VDCFilter Type 5% DC choke Class 2 GMC/ RFIEMC Complies with EN50082-1, -2 EN61800-3Communication Protocol RS485 JCI N2, MODBUS, BACnet MS/TP Ethernet BACnet/ IP, Modbus/TCPOperating Humidity 0 to 95% RH (non-condensing)Operating Temperature 14° to 104°F (-10° to 40°C)Approvals UL Listed File E190898 CE RoHSEco Friendly YesWarranty 3 years

DESCRIPTION

SmartVFD HVAC drives are all-purpose, and can handle both constant-torque and variable-torque loads . The firmware includes special features that make start-up and commissioning of HVAC applications especially easy . Application-specific startup wizards for pumps and fans, combined with the simple and intuitive user interface, make the SmartVFD a pleasure rather than a chore . Integration is a snap with the SmartVFD . It includes both Ethernet and RS485 connections, and will talk BACnet, Modbus, and JCI N2 . Take the complexity out of drive selection, installation, and startup - choose SmartVFD for your HVAC projects and start saving time, money, and manpower as well as energy .

FEATURES

• Intuitive commissioning• High resolution graphic interface• User manual included in firmware• Simple start-up wizard - pump or fan• Fire mode• 2 PID controllers • Real-time clock

SPECIFICATIONS

Terminal Signal Technical information

1 Reference output +10 VDC, +3%; Maximum current 10 mA

2Analog input,

voltage or current

Analog input channel 1; Short-circuited protected

0- +10VDC (Ri = 200 kΩ)

4-20 mA (Ri = 250 Ω)

Resolution 0.1%, accuracy ±1%

Selection V/mA with dip-switches

3Analog input

common (current)

Differential input if not connected to ground;

Allows ±20V differential mode voltage to GND

4Analog input

voltage or current

Analog input channel 2; Short-circuited protected

Default: 4-20 mA (Ri =250 Ω)

0-10 VDC (Ri = 200kΩ)

Resolution 0.1%, accuracy ±1%

Selection V/mA with dip-switches

5Analog input

common (current)

Differential input if not connected to ground;

Allows 20V differential mode voltage to GND

6 24VDC aux. voltage

+24 VDC, ±10%, max volt. ripple < 100mVrms; max. 250mA

Dimensioning: max. 1000mA/control unit.

Short-circuit protected

7 I/O groundGround for reference and controls (connected internally to

frame earth through 1MΩ)

8 Digital input 1 Positive or negative logic

Ri = min. 5kΩ

0...5VDC = “0”

15…30VDC = “1”

9 Digital input 2

10 Digital input 3

11Common A for

DIN1-DIN6

Digital inputs can be disconnected from ground

12 24 VDC aux. voltage

+24 VDC, ±10%, max volt. ripple < 100mVrms; max. 250mA

Dimensioning: max. 1000mA/control unit.

Short-circuit protected

13 I/O groundGround for reference and controls (connected internally to

frame earth through 1MΩ)

14 Digital input 4 Positive or negative logic

Ri = min. 5kΩ

0...5VDC = “0”

15…30VDC = “1”

15 Digital input 5

16 Digital input 6

17Common A for

DIN1-DIN6Digital inputs can be isolated from ground.

18Analog signal

(+output)Analog output channel 1, selection 0 -20mA, load <500Ω

Default: 0-20 mA/0-10 VDC

Resolution 0.1%, accuracy ±2%

Selection V/mA with dip-switches

Short-circuited protected.19

Analog output

common

3024 VDC auxiliary

input voltageCan be used as external power backup for the control unit

A RS485 Differential receiver/transmitter

Set bus termination with dip switchesB RS485

STANDARD I/O BOARD

Page 27: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

705

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVESSMARTVFD HVAC

Relay

board

21Relay

Output 1*

Switching capacity 2 4VDC/8A250 VAC/8A125 VDC/0.4AMin.switching load 5V/10mA

22

23

24Relay

Output 2*

Switching capacity 24 VDC/8A250 VAC/8A125 VDC/0.4AMin.switching load 5V/10mA

25

26

28 ThermistorInput

Rtrip = 4.7 kΩ (PTC); Measuring voltage 3.5V29

* If 230VAC is used as control voltage from the output relays, the control circuitry must be powered with a separate isolation transformer to limit short circuit current and ovrvoltage spikes. This is to prevent welding on the relay contacts. Refer to standard EN 60204-1, section 7.2.9

Relay board with two change-over contact (SPDT) relays and one relay with normally-open (NO or SPST) contact. 5.5 mm isolation between channels.

RelayBoardTerminal Signal

21 RO1/1 Relay output 1

22 RO1/2

23 RO1/3

24 RO2/1 Relay output 2

25 RO2/2

26 RO2/3

28 TI1+Thermistor input

29 TI1-

From Standard I/O board

From term.

#13

From term.

#12

RUN

DIMENSIONS AND WEIGHTS

RELAY BOARD TECHNICAL INFORMATION RELAY CONNECTIONS

Frame 208/ 230 VAC 460 VACEnclosure NEMA type

Width in. (cm)

Height in. (cm)

Depth in. (cm)

Weight lb (kg)

4 0.75-4 HP 1.5-7.5 HP 1 5 (12.7) 12.9 (32.77) 7.5 (19.05) 13.0 (5.9)4 0.75-4 HP 1.5-7.5 HP 12 5 (12.7) 12.9 (32.77) 7.5 (19.05) 13.0 (5.9)4 0.75-4 HP 1.5-7.5 HP 3 20.5 (52.07) 20 (50.8) 10 (25.4) 13.0 (5.9)5 5-10 Hp 10-20 Hp 1 5.7 (14.48) 16.5 (41.91) 8.4 (21.34) 22.0 (10.0)5 5-10 Hp 10-20 Hp 12 5.7 (14.48) 16.5 (41.91) 8.4 (21.34) 22.0 (10.0)5 5-10 Hp 10-20 Hp 3 20.5 (52.07) 24 (60.96) 10 (25.4) 22.0 (10.0)6 15-20 Hp 25-40 Hp 1 7.7 (19.56) 21.9 (55.63) 9 (22.86) 44.0 (20.0)6 15-20 Hp 25-40 Hp 12 7.7 (19.56) 21.9 (55.63) 9 (22.86) 44.0 (20.0)6 15-20 Hp 25-40 Hp 3 28.5 (72.39) 36 (88.9) 10 (25.4) 44.0 (20.0)7 25-40 Hp 50-75 Hp 1 9.3 (23.62) 25.4 (64.51) 10.2 (25.91) 83.0 (37.7)7 25-40 Hp 50-75 Hp 12 9.3 (23.62) 25.4 (64.51) 10.2 (25.91) 83.0 (37.7)7 25-40 Hp 50-75 Hp 3 28.8 (73.15) 48 (121.92) 12 (30.48) 83.0 (37.7)8 50-75 Hp 100-150 Hp 1 11.4 (28.96) 38 (96.52) 13.5 (34.29) 154.0 (70.0)8 50-75 Hp 100-150 Hp 12 11.4 (28.96) 38 (96.52) 13.5 (34.29) 154.0 (70.0)8 50-75 Hp 100-150 Hp 3 11.4 (28.96) 38 (96.52) 13.5 (34.29) 154.0 (70.0)9 100-125 Hp 200-250 Hp 1 18.9 (48.00) 45.3 (115.06) 14.4 (36.58) 238.0 (108.2)9 100-125 Hp 200-250 Hp 12 18.9 (48.00) 45.3 (115.06) 14.4 (36.58) 238.0 (108.2)

Page 28: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

706

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

ORDERING INFORMATION

HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVESSMARTVFD HVAC

HP Amps Frame NEMA 1 NEMA 12 NEMA3R

460 VAC1.5 3.4 4 HVFDSD3C0015G100 HVFDSD3C0015G200 HVFDSD3C0015G300

2 4.8 4 HVFDSD3C0020G100 HVFDSD3C0020G200 HVFDSD3C0020G300

3 5.6 4 HVFDSD3C0030G100 HVFDSD3C0030G200 HVFDSD3C0030G300

4 8 4 HVFDSD3C0040G100 HVFDSD3C0040G200 HVFDSD3C0040G300

5 9.6 4 HVFDSD3C0050G100 HVFDSD3C0050G200 HVFDSD3C0050G300

7.5 12 4 HVFDSD3C0075G100 HVFDSD3C0075G200 HVFDSD3C0075G300

10 16 5 HVFDSD3C0100G100 HVFDSD3C0100G200 HVFDSD3C0100G300

15 23 5 HVFDSD3C0150G100 HVFDSD3C0150G200 HVFDSD3C0150G300

20 31 5 HVFDSD3C0200G100 HVFDSD3C0200G200 HVFDSD3C0200G300

25 38 6 HVFDSD3C0250G100 HVFDSD3C0250G200 HVFDSD3C0250G300

30 46 6 HVFDSD3C0300G100 HVFDSD3C0300G200 HVFDSD3C0300G300

40 61 6 HVFDSD3C0400G100 HVFDSD3C0400G200 HVFDSD3C0400G300

50 72 7 HVFDSD3C0500G100 HVFDSD3C0500G200 HVFDSD3C0500G300

60 87 7 HVFDSD3C0600G100 HVFDSD3C0600G200 HVFDSD3C0600G300

75 105 7 HVFDSD3C0750G100 HVFDSD3C0750G200 HVFDSD3C0750G300

100 140 8 HVFDSD3C1000G100 HVFDSD3C1000G200 HVFDSD3C1000G300

125 170 8 HVFDSD3C1250G100 HVFDSD3C1250G200 HVFDSD3C1250G300

150 205 8 HVFDSD3C1500G100 HVFDSD3C1500G200 HVFDSD3C1500G300

200 261 9 HVFDSD3C2000G100 HVFDSD3C2000G200 -

250 310 9 HVFDSD3C2500G100 HVFDSD3C2500G200 -

208/ 230 VAC0.75 3.7 4 HVFDSD3A0007G100 HVFDSD3A0007G200 HVFDSD3A0007G300

1 4.8 4 HVFDSD3A0010G100 HVFDSD3A0010G200 HVFDSD3A0010G300

1.5 6.6 4 HVFDSD3A0015G100 HVFDSD3A0015G200 HVFDSD3A0015G300

2 8 4 HVFDSD3A0020G100 HVFDSD3A0020G200 HVFDSD3A0020G300

3 11 4 HVFDSD3A0030G100 HVFDSD3A0030G200 HVFDSD3A0030G300

5 18 5 HVFDSD3A0050G100 HVFDSD3A0050G200 HVFDSD3A0050G300

7.5 24 5 HVFDSD3A0075G100 HVFDSD3A0075G200 HVFDSD3A0075G300

10 31 5 HVFDSD3A0100G100 HVFDSD3A0100G200 HVFDSD3A0100G300

15 48 6 HVFDSD3A0150G100 HVFDSD3A0150G200 HVFDSD3A0150G300

20 62 6 HVFDSD3A0200G100 HVFDSD3A0200G200 HVFDSD3A0200G300

25 75 7 HVFDSD3A0250G100 HVFDSD3A0250G200 HVFDSD3A0250G300

30 88 7 HVFDSD3A0300G100 HVFDSD3A0300G200 HVFDSD3A0300G300

40 105 7 HVFDSD3A0400G100 HVFDSD3A0400G200 HVFDSD3A0400G300

50 140 8 HVFDSD3A0500G100 HVFDSD3A0500G200 HVFDSD3A0500G300

60 170 8 HVFDSD3A0600G100 HVFDSD3A0600G200 HVFDSD3A0600G300

75 205 8 HVFDSD3A0750G100 HVFDSD3A0750G200 HVFDSD3A0750G300

100 261 9 HVFDSD3A1000G100 HVFDSD3A1000G200 -

125 310 9 HVFDSD3A1250G100 HVFDSD3A1250G200 -

Drives are typically sized to match the horsepower rating of the motor, which will be accurate 95 percent of the time. For greatest accuracy, drives should be sized based upon the Full Load Amps or current draw of the motor. The VFD must have a slightly larger current rating maximum.

ACCESSORIES32006630-001 LON communication cardHVFDCABLE Commissioning cable and USB adaptor

Page 29: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

707

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

Transformer

Three bypass contactorsshown (BC-1, BC-2, BC-3).BC-3 not supplied in a twocontactor bypass

M

HVFDSB3

Main Disconnect

L1

L2

L3

UVW

L1

L2

L3

BC-3 BC-1

BC-2

To factory wired bypass controls (switches, coils, etc.)

WIRING

Supply Voltage 208 VAC, 3 phase, 60 Hz 230 VAC, 3 phase, 60 Hz 480 VAC, 3 phase, 60HzMotor Rating 1 .0 to 250 HpFrequency Range 0 - 320 HzAcceleration Time 0 .1 - 3000 secondsDeceleration Time 0 .1 - 3000 secondsDigital Inputs 6 factory presetAnalog Input 2; 0-10V or 4-20 mA programmableDigital Output Open collector,

max . load 48V / 50 mAAnalog Output 1; 4-20 mA

Relay Outputs 2 each SPDT 8A at 24 VDC or 250 VAC 0 .4A at 125 VDC Minimum load 10Ma at 5 VAC/VDC

Filter Type 5% DC choke , and class 2 GMC/RFIEMC Complies with EN50082-1, -2Communication Protocol RS485 BACnet MS/TP, N2, Modbus Ethernet BACnet/ IP, Modbus/TCPOperating Humidity 0 to 95% RH (non-condensing)Operating Temperature 14° to 104°F (-10° to 40°C)Approvals UL Listed File #E190898 cUL CE

RoHSEco Friendly YesWarranty 3 years

HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASSSMARTVFD HVAC WITH BYPASS ASSEMBLY

DESCRIPTION

Honeywell’s integral bypass and disconnect system make applying the SmartVFD drive a snap . Available with a simple fused disconnect switch, a 2-contactor bypass assembly, or a 3-contactor bypass assembly, it simplifies installation . All the features of the SmartVFD are included -- a wide array of configurable inputs and outputs, and all the most popular network protocols, and the super easy startup wizards that speed commissioning . All drives feature Hand-Off-Auto operation as a is fully integrated keypad function . Make the SmartVFD choice for your variable speed drive needs .

FEATURES

• Disconnect, 2-, or 3-contactor bypass• Fused disconnect• Auto bypass available• Available in NEMA 1, 12, or 3R enclosure types• Compact size• SmartVFD wizard for pump or fan control• Intuitive commissioning• High resolution graphic interface• User manual built in to firmware

SPECIFICATIONS

Note: Typical wiring shown . Refer to product installation manual for electrical wiring connections and requirements .

Page 30: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

708

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Our five configurations make it easy for you to select the right bypass to complete your drive package . All bundles are available in NEMA 1, NEMA 12 and ventilated NEMA 3R HOA (HAND OFF AUTO) .

SmartVFD Disconnect Only• Adds a fused disconnect to the VFD .

SmartVFD 2-Contactor BypassProvides an economical means of bypassing the VFD .• Freeze/Fire/Smoke Interlock

SmartVFD 3-Contactor BypassCommission, service or replace the VFD without affecting the operation of the motor .• Fused Disconnect• Freeze/Fire/Smoke Interlock• VFD is isolated from power with motor running in BYPASS

mode• TEST position powers the VFD without sending power to the

motor

SmartVFD 3-Contactor Bypass with Auto-BypassThe package adds the control capabilities below to the standard three contactor bypass .• Any VFD fault will automatically send the bypass to BYPASS

mode• A contact closure sends the bypass to BYPASS mode• Dry contacts indicate when the bypass is in BYPASS mode,

alerting the building management system

SMART VFD BYPASS CONFIGURATIONS

HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASSSMARTVFD HVAC WITH BYPASS ASSEMBLY

DIMENSIONS - IN (CM)

Frame Size

Horsepower and Voltage NEMA 1 NEMA 12 NEMA 3 R

208/ 230 VAC 460 VAC Configuration Width Height Depth Width Height Depth Width Height Depth

4 0.75-4 Hp 1.5-7.5 HpDisconnect 8.9 (22.6) 8.9 (22.6) 10.7 (26.2) 12.0 (29.4) 36.0 (88.2) 8.8 (21.6) 20.5 (50.2) 20.0 (49.0) 10.0 (24.5)

2-Contactor 8.9 (22.6) 8.9 (22.6) 10.7 (26.2) 16.0 (39.2) 36.0 (88.2) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5)

3-Contactor, 3-Contactor

w/ Auto- Bypass8.9 (22.6) 8.9 (22.6) 10.7 (26.2) 16.0 (39.2) 36.0 (88.2) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5)

5 5-10Hp 10-20 HpDisconnect 8.9 (22.6) 34.5 (84.5) 10.7 (26.2) 12.0 (29.4) 40.0 (98) 8.8 (21.6) 24.5 (60.0) 24.0 (58.8) 10.0 (24.5)

2-Contactor 8.9 (22.6) 34.5 (84.5) 10.7 (26.2) 16.0 (39.2) 44.0 (107.8) 8.8 (21.6) 28.5 (69.8) 30.0 (73.5) 10.0 (24.5)

3-Contactor, 3-Contactor

w/ Auto- Bypass8.9 (22.6) 41.5 (101.7) 10.7 (26.2) 16.0 (39.2) 44.0 (107.8) 8.8 (21.6) 28.5 (69.8) 30.0 (73.5) 10.0 (24.5)

6 15-20Hp 25-40 HpDisconnect 12.4 (30.4) 45.0 (110.3) 12.6 (30.9) 16.0 (39.2) 46.0 (112.7) 10.8 (26.5) 28.5 (69.8) 36.0 (88.2) 10.0 (24.5)

2-Contactor 12.4 (30.4) 45.0 (110.3) 12.6 (30.9) 20.0 (49.0) 54.0 (132.3) 10.8 (26.5) 34.5 (84.5) 36.0 (88.2) 10.0 (24.5)

3-Contactor, 3-Contactor

w/ Auto- Bypass12.4 (30.4) 55.0 (134.8) 12.6 (30.9) 20.0 (49.0) 54.0 (132.3) 10.8 (26.5) 34.5 (84.5) 36.0 (88.2) 10.0 (24.5)

7 25-40Hp 50-75 HpDisconnect 20.84 (51.1) 51.5 (126.2) 11.4 (27.9) 16.0 (39.2) 50.0 (122.5) 11.8 (28.9) 28.5 (69.8) 48.0 (117.6) 12.0 (29.4)

2-Contactor 20.84 (51.1) 51.5 (126.2) 11.4 (27.9) 24.0 (58.8) 64.0 (156.8) 13.6 (33.3) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)

3-Contactor, 3-Contactor

w/ Auto- Bypass20.84 (51.1) 59.0 (144.6) 11.4 (27.9) 24.0 (58.8) 64.0 (156.8) 13.6 (33.3) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)

8 50-75 Hp 100-150 HpDisconnect 25.0 (61.3) 60.0 (147.0) 16.2 (39.7) 20.0 (49.0) 64.0 (156.8) 15.1 (36.9) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)

2-Contactor 25.0 (61.3) 60.0 (147.0) 16.2 (39.7) 56.0 (137.2) 48.0 (117.6) 15.1 (36.9) 40.4 (98.9) 60.0 (147.0) 12.0 (29.4)

3-Contactor, 3-Contactor

w/ Auto- Bypass25.0 (61.3) 70.0 (171.5) 16.2 (39.7) 56.0 (137.2) 48.0 (117.6) 15.1 (36.9) 40.4 (98.9) 60.0 (147.0) 12.0 (29.4)

Page 31: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

709

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASSSMARTVFD HVAC WITH BYPASS ASSEMBLY

ORDERING INFORMATION

Example: HVDSB3C0400G130 480 VAC, 40 Hp, Smart VFD NEMA 1with graphic keypad display, 3 contractor bypass

HVFDSB3 Honeywell SmartVFD HVAC

A 208 VAC - up to 75 Hp

B 230 VAC - up to 75 Hp

C 480 VAC - up to 150 Hp

Motor Horsepower

0007 .75 Hp 208, 230 & 480 VAC

0010 1 Hp 208, 230 & 480 VAC

0015 1.5 Hp 208, 230 & 480 VAC

0020 2 Hp 208, 230 & 480 VAC

0030 3 Hp 208, 230 & 480 VAC

0040 4 Hp 208, 230 & 480 VAC

0050 5 Hp 208, 230 & 480 VAC

0075 7.5 Hp 208, 230 & 480 VAC

0100 10 Hp 208, 230 & 480 VAC

0150 15 Hp 208, 230 & 480 VAC

0200 20 Hp 208, 230 & 480 VAC

0250 25 Hp 208, 230 & 480 VAC

0300 30 Hp 208, 230 & 480 VAC

0400 40 Hp 208, 230 & 480 VAC

0500 50 Hp 208, 230 & 480 VAC

0600 60 Hp 208, 230 & 480 VAC

0750 75 Hp 208, 230 & 480 VAC

1000 100 Hp 480 VAC

1250 125 Hp 480 VAC

1500 150 Hp 480 VAC

User Interface

G Graphic User Interface

Enclosure

1 NEMA 1

2 NEMA 12

3 NEMA 3R

Options

10 Disconnect only

20 Drive with 2 contractor BYPASS

30 Drive with 3 contactor BYPASS

31 Drive with 3 contactor BYPASS, w/ Fused disconnect and Auto-bypass

HVFDSB3 C 0400 G 1 30

ACCESSORIES PAGE32006630-001 LON communication card HVFDCABLE Commissioning cable and USB adaptor

Page 32: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

710

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

MOTOR CONTROL ACRONYMS, CALCULATIONS & CONVERSION FORMULAS

AC = alternating current

ANSI = American National Standards Institute

ASD = adjustable speed drive

BHP = brake horsepower

CFM = cubic feet per minute

CSA = Canadian Standards Association

CSI = current source inverter

DC = direct current

DSP = digital signal processor

ECC = eddy current coupling

FPM = feet per minute

GPM = gallon per minute

GTO = gate turnoff (thyristor)

HDF = harmonic distortion factor

IGBT = insulated gate bi-thermal thyristor

IEEE = Institute of Electrical and Electronics Engineers

LCI = load-commutated inverter

NEMA = National Electrical Manufacturers Association

NPV = net present value

PAM = pulse amplitude modulation

PLC = programmable logic controller

PWM = pulse width modulated (inverter)

SCR = silicon-controlled rectifier

SR = switched reluctance

THD = total harmonic distortion

V = voltage

VSI = variable source inverter

VVI = variable voltage inverter

Calculating the Horsepower Requirement of a Load

The mechanical load required by the driven equipment is known as the Brake Horsepower (BHP) . The BHP value can be calculated by the following: BHP = T x N (required HP) 5,250

Where: HP = horsepower supplied by the motor T = Torque (lb-ft) force x radius N = base speed of motor (rpm)

Once the machine BHP (speed times torque) requirement is determined, horsepower (HP) can be calculated:

Rated motor HP = Motor Efficiency (%) / 100 = available HP

If the calculated horsepower falls between standard available motor ratings, select the higher available horsepower rating . It is good practice to allow some margin when selecting the motor horsepower .

CONVERSION FORMULAS/FACTORS

Multiply By To ObtainLength Meters 3.281 Feet

Meters 39.37 Inches

Inches 0.025 Meters

Feet 0.305 Meters

Torque Newton-Meters 0.738 lb-ft

lb-ft 1.356 Newton-Meters

lb-in 0.083 lb-ft

lb-ft 12.00 lb-in

Rotation RPM 6.00 Degrees per second

RPM 0.105 Radius per second

Degrees per second 0.167 RPM

Radius per second 9.549 RPM

Power Watts 0.001 HP

lb-ft per minute 0.000 HP

HP 746 Watts

HP 30300 lb-ft/min

Temperature Degrees C = (Degrees F-32) x 5/9Degrees F = (Degrees C x 9/5) + 32

Page 33: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!

711

MOTOR CONTROLSM

OTO

R CONTRO

LS

12

WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

GLOSSARY OF COMMON TERMS

Alternating Current: The flow of electricity which changes direction on a regular continuous cycle reaching a maximum in one direction, decreasing to zero, then reversing to reach a maximum in the opposite direction .

Air Gap: The space between the rotating and stationary part of an electric motor . Magnetic energy is transferred across this gap .

Ambient: The air which surrounds a motor for air cooled machines .

Ampere: A unit of current which is a measure of the rate of electron flow . It is often abbreviated as Amp . The unit of current flow is the amp .

Breakdown Torque: The maximum torque that a motor can develop at rated voltage without stalling or an abrupt drop in speed .

Brush: A current carrying material which is in contact with an armature or slip ring assembly to provide an elec-trical connection between rotating and stationary components of a motor . Capacitor: A device which can store electrical charge . In an AC circuit, a capacitor causes the voltage to lead the current . The unit of capacitance is the Farad .

Commutator: An assembly which is mounted on the shaft of a DC motor to provide the switching functions between the armature coils and the power supply .

Conductor: Any material which offers little resistance to the flow of electricity such as copper .

Duty Cycle: The relationship between the operating time and the resting time of an electric motor .

Eddy Current: Localized currents in electrical steels that are caused by alternating magnetic flux resulting in losses and heating .

Efficiency: The ratio of mechanical output to the electrical input power of a motor .

Electromotive Force (emf): A synonym for voltage usually used to describe induced or generated voltages in an electric circuit .

Field: The term used to describe the stationary part of a DC machine . The field provides the magnetic flux which interacts with the armature .

Flux: The magnetic field which is established around a current carrying conductor or a permanent magnet .

Frequency: The rate at which alternating current reverses its direction of flow . The unit of frequency is either Hertz or cycles per second .

Full Load Current: The current that a motor draws at rated voltage, frequency and load .

Full Load Slip: The difference between the synchronous speed of a motor and full load speed . It is often ex-pressed as a ratio of the synchronous speed to full load speed in percent .

Full Load Speed: The speed of the motor at rated voltage, frequency and load .

Full Load Torque: The torque that is necessary to produce rated horsepower at full load speed .

Horsepower: A measurement of power used to rate electric motors . The unit of power rating in motors is either horsepower or kilowatts . One horsepower is equal to 746 watts .

Page 34: HUMIDITY - KeleMOTOR CONTROLS fi˝ 684 MOTOR CONTROLS 12 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 ABB 3 PHASE MOTOR STARTER A SERIES All units

NEW!MOTOR CONTROLS

712

NEW!M

OTO

R CO

NTRO

LS

12

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

Impedance: The total opposition a circuit offers to the flow of alternating current . It is the vector sum of resis-tance and reactance .

Inductance: The property of an electrical circuit which opposes a change in current due to the magnetic field induced by that current .

Inertia: Inertia is the resistance an object has to a change in its state of motion . It is determined by the weight of the object multiplied by the square of the radius of gyration (k) . Rotating parts do not operate at the same speed, therefore calculating the inertia for each moving part allows rotating parts to be considered as a single unit work-ing together .

Line Voltage: The voltage supplied to the input terminals of an electric device .

Magnetomotive Force (mmf): The magnetic energy supplied in the establishment of magnetic flux . It is analo-gous to the electromotive force in an electric circuit .

Phase: A term used to describe the spatial relationship of windings in an electric motor or voltages and currents in an electric circuit .

Power Factor: A measurement of the difference in phase between voltage and current in an electric circuit . Most electrical devices cause the current to lag the voltage because of inductance . The voltage leads the cur-rent in capacitive circuits .

Reactance (inductive): The property of a magnetic circuit which causes the voltage to lag the current .

Resistance: The property of an electrical conductor which impedes the flow of electricity . The unit of resistance is the ohm .

Rotor: The rotating member of an electric motor .

Service Factor: The service factor of an AC motor is a multiplier which when applied to the rated horsepower indicates the permissible loading which may be carried under the conditions specified for the service factor .

Slip: The ratio between the synchronous speed and the operating speed of an induction motor, often expressed as a percent .

Stator: The stationary part of an AC motor housing the steel laminations and the windings .

Temperature Rise: The difference between the temperature of the windings of an operating motor and the am-bient temperature .

Torque: The turning force applied to a shaft, usually expressed as pound-feet (English) or Newton-meters (met-ric) .

Voltage: The standard unit of electromotive force which produces a flow of current in a conductor . The unit of electromotive force is the volt .

Watt: A measurement of power in an electrical circuit which is equal to one joule of energy being expended in one second .

GLOSSARY OF COMMON TERMS