htvblee-mvp series barrier-free water coolers

12
PAGE 1 98496C (Rev. A - 3/09) HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C OWNERS MANUAL HTVBLEE-MVP Series Barrier-Free Water Coolers 8 54, 68 23, 36, 51 30 4, 16 57 12 66, 70 56 6 35 69 27 67 33 15, 59, 60 35 25 65 7 65 2, 3, 5 49 62 41 Fig. 1 (A) - See. Fig. 10 58 43 53 34 40 22, 29 64 31 28 77 45, 46 35 63 42 55 21, 29 18, 20, 26 24 13 52 17 44 1, 47 23, 36, 51

Upload: others

Post on 28-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 1 98496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

OWNERS MANUAL

HTVBLEE-MVP Series Barrier-Free Water Coolers

8

54, 68 23, 36, 51

30

4, 16

57

12

66, 70

56

6

35

69

27

67

33

15, 59, 60

35

2565

765

2, 3, 5

49

62

41

Fig. 1

(A) - See. Fig. 10

58

43 53

34

40

22, 29

64

31

287745, 4635

63

42

55

21, 29

18,20,26

24

13

52

17

44

1, 47

23, 36, 51

Page 2: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 298496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

Fig. 2 LE

GE

ND

/LE

YE

ND

A/L

ÉG

EN

DE

A =

RE

CO

MM

EN

DE

D W

AT

ER

SU

PP

LY L

OC

AT

ION

. S

HU

T O

FF

VA

LVE

(N

OT

FU

RN

ISH

ED

) TO

AC

CE

PT

3/8

” O

.D. U

NP

LA

TE

DC

OP

PE

R T

UB

E.

La U

BIC

AC

ION

RE

CO

ME

ND

AD

A d

e A

BA

ST

EC

IMIE

NT

O D

E A

GU

A. A

PA

GU

E V

ALV

ULA

(no

AM

UE

BLA

DO

) AC

EP

TAR

3/8

O. D

.

E

l TU

BO

del

CO

BR

E d

e U

NP

LAT

ED

L’E

MP

LAC

EM

EN

T D

E P

RO

VIS

ION

D’E

AU

RE

CO

MM

AN

DE

. ET

EIN

DR

E L

A S

OU

PA

PE

(P

AS

FO

UR

NI)

AC

CE

PT

ER

3/8

O.D

. LE

TU

BE

DE

CU

IVR

E D

E U

NP

LAT

ED

.B

= R

EC

OM

ME

ND

ED

LO

CA

TIO

N F

OR

WA

ST

E O

UT

LE

T 1

-1/4

” O

.D.

DR

AIN

UB

ICA

CIÓ

N R

EC

OM

EN

DA

DA

PA

RA

EL

DR

EN

AJE

DE

SA

LID

A D

E A

GU

A, D

E 1

¼”

DE

DIÁ

ME

TR

O.

EM

PLA

CE

ME

NT

RE

CO

MM

AN

PO

UR

LE

DR

AIN

DE

D.E

. 1-1

/4"

DE

SO

RT

IE D

’EA

U.

C =

1-1

/2 T

RA

P N

OT

FU

RN

ISH

ED

**P

UR

GA

DO

R D

E 1

-1/2

NO

PR

OP

OR

CIO

NA

DO

**S

IPH

ON

1-1

/2 N

ON

FO

UR

NI*

*D

= E

LE

CT

RIC

AL

SU

PP

LY (

3) W

IRE

RE

CE

SS

ED

BO

XC

AJA

RE

CE

SIV

A D

E A

LAM

BR

ES

(3)

DE

SU

MIN

IST

RO

ELÉ

CT

RIC

OB

OÎT

E E

NC

AS

TR

ÉE

D’A

LIM

EN

TAT

ION

ÉLE

CT

RIQ

UE

(3)

FIL

SE

= IN

SU

RE

PR

OP

ER

VE

NT

ILA

TIO

N B

Y M

AIN

TAIN

ING

6"

(152

mm

) (M

IN.)

CL

EA

RA

NC

E F

RO

M C

AB

INE

T L

OU

VE

RS

TO

WA

LL.

AS

EG

UR

E U

NA

VE

NT

ILA

CIÓ

N A

DE

CU

AD

A M

AN

TE

NIE

ND

O U

N E

SP

AC

IO E

6"

(152

mm

) (M

ÍN.)

DE

HO

LGU

RA

EN

TR

E L

A R

EJI

LLA

DE

VE

NT

ILA

CIÓ

N D

EL

MU

EB

LE Y

LA

PA

RE

DA

SS

UR

EZ

-VO

US

UN

E B

ON

NE

VE

NT

ILA

TIO

N E

N G

AR

DA

NT

6"

(152

mm

) (M

IN.)

EN

TR

E L

ES

ÉV

EN

TS

DE

L’E

NC

EIN

TE

ET

LE

MU

R.

F =

5/1

6 B

OLT

HO

LE

S F

OR

FA

ST

EN

ING

UN

IT T

O W

ALL

AG

UJE

RO

S D

E L

AS

TU

ER

CA

S D

E 5

/16

PA

RA

SU

JETA

R L

A U

NID

AD

A L

A P

AR

ED

TR

OU

S D

’ÉC

RO

US

5/1

6 P

OU

R F

IXE

R L

’AP

PA

RE

IL A

U M

UR

*AD

A R

EQ

UIR

EM

EN

T

*RE

QU

ISIT

O D

E A

.D.A

.

*EX

IGE

NC

E A

DA

Red

uce

heig

ht b

y 3”

(76

mm

) fo

rin

stal

latio

n of

chi

ldre

ns A

DA

coo

ler.

Red

uzca

la a

ltura

por

3”

(76

mm

) pa

rala

inst

alac

ión

de c

hild

rens

AD

A m

ás f

resc

o.

Réd

uire

la h

aute

ur p

ar 3

(76

mm

) po

url’i

nsta

llatio

n de

chi

ldre

ns A

DA

plu

s fr

ais.

NO

TE

: Hal

sey

Tayl

or’s

rec

omm

ende

d or

ifice

mou

ntin

g he

ight

for

chi

ldre

n 38

” to

46”

tall

(app

rox.

fou

r th

roug

h se

ven

year

s ol

d) is

23”

from

the

fin

ishe

d flo

or.

Page 3: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 3 98496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

HANGER BRACKET & TRAP INSTALLATION1) Remove the hanger bracket fastened to back of the cooler by removing one (1) screw.2) Mount the hanger bracket as shown in Fig. 2 & Fig 3.NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes.IMPORTANT:

7 in. (178mm) dimension from wall to centerline of trap must be maintained for proper fit.

INSTALLATION OF COOLER3) Hang the cooler on the hanger bracket. Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 3.4) Remove the two (2) screws holding the bottom cover at the bottom of cooler. (Shown in Fig. 16) Remove the bottom cover by pulling straight down and set aside.5) Connect water inlet line--See Note 4 of General Inst.6) Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap. Assemble the slip nut and gasket to the trap and tighten securely.IMPORTANT: If it is necessary to cut the wasteline, loosen the clamp (Item 62) at the drain fitting (Item 41) and remove. Check for leaks after re-assembly.8) Plug in electrical power and re-install bottom cover. Unit must have electrical power to have water flow.

CAUTION: PLASTIC COMPONENTSAny service of this unit that requires use of a torch,care should be taken not to melt any of the plasticcomponents. To keep flame away from plastic, theuse of a shield may be required.

IMPORTANT:When installing cooler, do not solder 3/8” copper inlet tubewhile inserted into union fitting as damage to o-ring andplastic will result.

CLEANING:Warm, soapy water or mild household cleaning productscan be used to clean the exterior panels of the HTVseries coolers. Use of harsh chemicals or petroleumbased cleaners WILL VOID THE WARRANTY.

Fig. 3

START UPAlso See General Instructions9) Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust screw located on upper side of frame (Item 43 or 44). See Fig. 3. CW adjustment will raise stream and CCW adjustment will lower stream. For best adjustment, stream should be 1-1/2” above bubbler hood. (See Fig. 4)NOTE: If continuous flow occurs at the end of the compressor cycle, turn cold control (Item 16) counterclockwise 1/4 turn.

CORRECT STREAMHEIGHT

Fig. 4

HANGER BRACKET (Item 10)

COOLER BACK

Page 4: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 498496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

Top Cover RemovalPlease remove bottom cover before removing top cover. To remove top cover(Item 37), use a small screwdriver to release the snap for the top cover as shownin Fig. 5. Then pull the small tabs on each side of the top cover outward slightlyand slide upward to remove.

FIG. 6

37

Small tabs

Cleaning the strainerTo clean the strainer, unscrew the cap of thesolenoid valve. Remove screen and rinsethoroughly with water. Insert screen backinto solenoid valve and screw cap on. Makesure the o-ring is placed properly.

FIG. 5

76

ScreenMallaEcran

O-ringRetén anularJoint Torique

CapTapa

Bouchon

51

36

23

Page 5: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 5 98496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

Removing the basinTo remove the basin (Item 12 or 34), remove two screws (Item 58) on top of the basin(Shown in Fig. 7). Then remove the four screws (Item 71) located underneath thedispenser bottom (Item 39 or 50) as shown in Fig. 7. Finally pull polytube (Item 35)out of bubbler nipple (Item 47) as shown in Fig. 8. and remove the basin.

FIG. 8

FIG. 7

58

58

12 or 34

71

1

33

47

35See figure below forOperation of QuickConnect Fittings

Filter Installation Detail(Some parts hidden for clarity)

FIG. 9

48, 65

49

Page 6: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 698496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

SENSOR RANGE ADJUSTMENT: (A)The electronic sensor used in this cooler is factory pre-set for a “visual” range of36 inches (914 mm). If actual range varies greatly from this or a different settingis desired, follow the range adjustment procedure below: - Using a small tip screwdriver, locate range adjustment screw through the small hole between the sensor lenses (A). Turn this screw clockwise to increase range and counterclockwise to decrease range.

CAUTION: Complete range of sensor (24-46 inches/610-1168mm) is only oneturn of the adjusting screw.

SENSOR CONTROL: If sensor fails to operate valve mechanism or operateserratically, check the following. A. Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler. B. Check wire connections at the solenoid valve and sensor. CAUTION: Make sure unit is unplugged before checking any wiring. C. Ensure proper operation of solenoid valve. If there is an audible clicking sound yet no water flows,look for an obstruction in the valve itself or elsewhere in the water supply line.

FIG. 10

(A)

65

9

27

1174

32

50

Green

YellowRed

Page 7: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 7 98496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

SENSOR WITH FILTER LIFE INDICATOR: (B)The electronic sensor includes LED filter status indicators that are factory preset to monitor filter life. The sensor monitors the “ON” timeof the water valve solenoid and keeps track of total time water is dispensed. There are (3) LED’s and indicates the following:

Green LED (Good) indicates that the filter is operating within 0% - 80% of its life.Yellow LED indicates that the filter is operating within 80% - 100% of its life.Red LED (Replace) indicates that the filter needs to be replaced since it has reached end of filter life.

Once power is applied to the water cooler, if all three LED’s flash then the Green LED aluminates, this indicates that there is some filterusage memory stored. When the Green LED comes on only, this indicates that the filter life is at absolute 0% of filter life. NOTE: Youmay have some very minimal filter life in memory upon receiving water cooler due to factory functional testing.

NOTE: The filter status will be retained until reset (see resetting filter monitor). The filter monitor will retain its memory evenduring a loss of power.

RESETTING FILTER LIFE INDICATOR: (C)In order to reset the filter life indicator status LED’s, you must remove the finishing plug (Item 75) underneath the front dispenser. With astraight blade screw driver or pen, reach inside opening and depress the reset button located on the back of the sensor as seen on (C) fora minimum of 1 second. (You may need a flashlight). Reinstall finishing plug and the Green LED should be illuminated indicating that thevisual filter monitor has been reset.

(B)

(C) - Reset Button

75

FIG. 11

Page 8: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 898496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

Switch Activation Detail

FIG. 12

Closed switch

Open switch

19

40

19

40

Page 9: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 9 98496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

Please remove the basin before removing the pushbars.Remove screw (Item 73) that holds pushbars in place. Thensimply slide the pushbars upward and remove. Do not discard thesmall springs or screws. When replacing pushbars do not overtighten screws, because the pushbars need to move freely.See Figures 13 & 14 for proper spring placement.

Pushbar Replacement

FIG. 13

FIG. 14

73

40

72

72

73

Page 10: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 1098496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

To access the refrigeration system and plumbingconnections, remove two screws (Item 66) to removebottom cover (Item 38).

Bottom Cover Removal

FIG. 15

58

10

58

44

37

58

1

1

71

71

71

70

66

38

70

66

46

73 40

58

6

32, 36, 51

75

71

58

12

33

73

40

SeeFig. 10 62

41

50

53

58

58

Page 11: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 11 98496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

SOLENOIDVALVE

GNDGREEN

PURPLEJUMPER

RIBBED LEADTO "N" TERMINALON POWER INLET

GREEN LEAD TOGROUND TERMINAL

ON POWER INLET

CONNECTS TOSENSOR TO

REFRIG. SIDE UNIT

SMOOTH LEADTO "L" TERMINALON POWER INLET

SOLENOIDVALVE

GNDGREEN

RIBBED(NEUTRAL)

SMOOTH(LINE)

PURPLEJUMPER

CONNECTS TOSENSOR ON

REFRIG. SIDE UNIT

SMOOTH (LINE)

COLD CONTROL

GNDFAN

RIBBED(NEUTRAL)

RED

SENSOR

WHT

BLK

23

1

56

MS

C

3

1 2

SOLENOIDVALVE

YELLOW

BLACK

RED

WHITE

GREEN

LED PCB

PURPLE JUMPER

GRND

GREEN

MALE TERMINAL ONWHITE SHORT LEADON POWERCORD

RELAY

COMPRESSOR

OVERLOADCONNECTS TO SENSORON LESS REFRIG. UNIT

COLD CONTROL

GNDFAN

RED

SENSOR

WHT

BLK

23

1

56

MS

C

3

1 2

SOLENOIDVALVE

PURPLE

YELLOW

BLACK

RED

WHITE

GREEN

LED PCB

GND

GREEN

SMOOTH LEADTO "L" TERMINALON POWER INLET

RIBBED LEADTO "N" TERMINALON POWER INLET

GREEN LEAD TO"GROUND" TERMINAL

ON POWER INLET

MALE TERMINAL ONWHITE SHORT LEADON POWERCORD

RELAY

COMPRESSOR

OVERLOAD CONNECTS TO SENSORON LESS REFRIG. UNIT

FIG. 16

14 (Black Jumper Wire)

WIRING DIAGRAMHTV8BLEE-MVP - 115V

WIRING DIAGRAMHTVD8BL-MVP - 115V

1728

WIRING DIAGRAMHTV8BLEE-MVP - 220V-50/60Hz

WIRING DIAGRAMHTVD8BL-MVP - 220V-50/60Hz

14 (Black Jumper Wire)

1728

FIG. 18

FIG. 17

FIG. 19

Page 12: HTVBLEE-MVP Series Barrier-Free Water Coolers

PAGE 1298496C (Rev. A - 3/09)

HTV8BLEEMVP*1C HTV8BLEEMVP*2C HVT8BLEEMVP*3C HTVDBLMVP*1C HTVDBLMVP*2C HTVDBLMVP*3C

REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM

PRINTED IN U.S.A.

2222 CAMDEN COURTOAK BROOK, IL 60523630.574.3500

100322740560100806740570101516143550111411443890

1903700028237C28238C28239C28246C28266C28803C28836C30646C30873C31490C31513C

3313300035768C35948C35959C35978C35980C36247C36279C36094C36158C36263C36265C

383970003841700145875C75717C51544C

5500112256092C56082C56098C56102C56106C56110C56118C56122C56128C56132C56154C56155C56159C56190C56191C56291C66654C66661C66697C66700C66703C66697C66762C70002C70009C70018C75718C70444C70682C70683C71014C75532C75533C75568C75583C75599C75663C75621C75625C75715C75716C98169C36090C

Gasket - Bubbler (upper and lower)Grommet - Compressor Mtg.

Stud - Compressor Mtg.Screw - #8 -36 x .38 Tri-Lobed

Clip - Compressor Mtg.Support Brace

Compressor BaseBracket - Fan Motor

Bracket - EEHanger BracketBracket - Mtg.

Basin - (Filter Monitor Unit)Fan Blade

Jumper Wire - BlackFan Motor

Cold ControlAdapter Tab

Cover - RelaySwitch Electrical

RelayPower Cord (Refrig. Unit)

Power Cord (Less Refrig. Unit)Solenoid ValveWiring Harness

Compressor Serv. Pak EMI 70Overload

Sensor - EE (Filter Monitor)Jumper Wire (Purple)Bushing - Strain Relief

Screw - #8-18 x .37 HHSMWaste Line Assy.Rivet - Push In

Bubbler - ChromeBasin

Tubing - Poly (Cut To length)Regulator Nut

Top CoverBottom Cover

Dispenser Bottom (Less Refrig. Unit)Pushbar

Fitting - DrainFan Shroud

Frame (Less Refrig. Unit)Frame (Refrig. Unit)

BushingDrain Cover

Nipple - BubblerBracket - Filter Mounting

Filter AssemblyDispenser Bottom (Refrig. Unit)

RegulatorHeat Exchanger

Waste Line (Refrig. Unit)Evaporator Assembly

DrierWaste Line (Less Refrig. Unit)

CondenserScrew - #10 x 1/2” Lg. HHSM

Screw - Fan MotorHex Nut

Screw - #8-18 Flat hd. Torx DriveClamp - Drain Gasket

Fitting - Tee 1/4”Fitting - Union 1/4”

Screw - #10-16 x .50” HHHLScrew - #10-16 x .63” THSM

Screw - #8 x .63 HHSMScrew #12 x 1.50” HHSMFitting - Elbow 5/16” x 1/4”

Clip - TinnermanScrew - #10 x .50 HHSM

Spring - PushbarScrew - HTV Pushbar

Rivet - Push In RatchetingFinishing Plug

Kit - Replacement Cap/Screen/O-RingGround Wire - Green

PART NO. DESCRIPTION

*REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.

123456789

1011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677

ITEM NO.

PARTS LIST

31431C36050C36066C36067C36248C36085C36195C35826C28350C

Fan MotorRelay

Power Cord (Refrig. Unit)Power Cord (Less Refrig. Unit)

Solenoid ValveCompressor Serv. Pak

OverloadPower Inlet

Bracket - Power Inlet

PART NO. DESCRIPTION

1520212223252678NS

ITEM NO.

220V-50Hz PARTS LIST

*

31431C36050C36066C36067C36248C36092C36174C35826C28350C

Fan MotorRelay

Power Cord (Refrig. Unit)Power Cord (Less Refrig. Unit)

Solenoid ValveCompressor Serv. Pak

OverloadPower Inlet

Bracket - Power Inlet

PART NO. DESCRIPTION

1520212223252678NS

ITEM NO.

220V-60Hz PARTS LIST

*

78 (220V)

FIG. 20

*