hp-2 / hp-4 wall wash recessed spackle & visible flange

12
HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview 1 of 12 Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary. © 2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21 Kicker Wall Wall Wash Orientation Step 1 Rough-Ins & Mounting Options Pages 2-3 Step 3 Opening Luminaires Page 5 Step 4 Mounting Starter to Structure Pages 6-7 Step 2 Identification & Preparation Page 4 Step 7 Closing Luminaires Pages 10-12 Step 5 Joining Luminaires Page 8 Ceiling Step 6 Securing Luminaire Joints Page 9 All power connections should be installed according to local/national codes by a Certified Electrician. This installation requires proper support as each luminaire is being installed. DO NOT attempt to join luminaires together on the floor. Damage may result when lifted. NOTES 0-10V Dimming Simple Plug-Together Wiring Universal & Robust Joints HELPFUL VIDEOS Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732

Upload: others

Post on 18-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation InstructionsOverview

1 of 12Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.comThis is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary.

© 2021 FINELITE, INC. ALL RIGHTS RESERVED. Form

- 98551 V3 EFFECTIVE DATE: 09/21

Kicker

Wall

Wall Wash Orientation

Step 1Rough-Ins & Mounting OptionsPages 2-3

Step 3Opening Luminaires

Page 5

Step 4Mounting Starter to StructurePages 6-7

Step 2Identification & PreparationPage 4

Step 7Closing Luminaires Pages 10-12

Step 5Joining LuminairesPage 8

Ceiling

Step 6Securing Luminaire JointsPage 9

• All power connections should be installed according to local/national codes by a Certified Electrician.

• This installation requires proper support as each luminaire is being installed.

• DO NOT attempt to join luminaires together on the floor. Damage may result when lifted.

NOTES

0-10V Dimming

SimplePlug-Together

Wiring

Universal &Robust Joints

HELPFUL VIDEOS

Prot

ecte

d by

one

or m

ore

US

Pate

nts:

891

5613

; D70

2,39

1; D

702,

390;

D70

0,73

2

2 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

Step 1 - Rough-Ins & Mounting Options

Z = Mounting Hole Location(Does not include endcaps)

HP-2 5"

HP-4 6"

Rough-In Lengths Rough-In Widths

W

L

X = Luminaire section length (Does not include endcaps)Y = Total run length of luminaire (Includes 1/8" for BOTH endcaps)Z = Mounting hole locationEndcap = 1/16"

Refer to Record Drawings and building plans to determine exact mounting, suspension points, and power feed locations.

* Tolerance +/- 1/16"

Spackle Flange (SF)

W

Visible Flange (VF)

W

• Use rough-in Length & Width dimensions and Record Drawings to determine rough-in measurements.• Build wall/ceiling with rough-in according to rough-in dimensions.• CRITICAL: Drywall or weak paneling must be secured to blocking (studs) around rough-in opening in

the wall/ceiling.

CONTINUED

L = Total Run Rough-In Length*Spackle Flange Visible Flange

HP-2 & HP-4 Y + 3/4" Y + 1/2"

W = Rough-In Width*Spackle Flange Visible Flange

HP-2 3-1/8" 2-1/2"

HP-4 4-7/8" 4-1/4"

* Tolerance +/- 1/16"

Mount Starter to Structure

Z Z Z Z

X2X1 X3Endcap

Starter Joiner EnderID: 1 ID: 2 ID: 3

Wal

l

Wal

l

Y

3 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

Step 1 - Rough-Ins & Mounting Options

1/4" Washer(by others)

1/4"-20 Nut(by others)

Mounting Option 1

Threaded Rod(by others)

¹ Wall/ceiling surface = drywall, wood, concrete or masonry, metal panels, tile, etc.² Support blocking = Wooden beams/studs, sheet metal framing beams, steel beams, concrete beams, etc. Use hardware appropriate to the beam material.

Mounting Options

Option 1 - Mount to Threaded Rod Option 2 - Mount to Structure

1/4"-20 Nut (by others)

1/4" Washer (by others)

1/4" Threaded Rod (by others)

Drywall Ceiling/Wall Drywall Ceiling/Wall

Structure Support (by others)

SupportBlocking2

(by others)

SupportBlocking2

(by others)

1/4" Lag Bolt (by others)

• Luminaire mounting holes sized for 1/4"-20 threaded rod.• Distance from threaded rod to wall/ceiling surface1 must be a minimum of 3-1/2".• Refer to Record Drawings to determine mounting hole locations on luminaires and install threaded rods to structure.

• Distance from support block to wall/ceiling surface1 must be a minimum of 4-1/8".• Refer to Record Drawings to determine mounting hole locations on luminaires and install support blocking² to structure.

3-1/2" min.4-1/8" min.

1/4"-20 Lag Bolt(by others)

Mounting Option 2

4 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

CAUTION

Arrange luminaires in order according to ID# at their install locations.

#10 x 1/2" ScrewPart# 92081Closing Luminairesp. 10, Step 7

1/4" WasherPart# 94082Opening Luminairesp. 5, Step 3Closing Luminairesp. 10, Step 7

#8-18 x 1/4" ScrewPart# 69026Opening Luminairesp. 5, Step 3Closing Luminairesp. 10, Step 7

Yoke BracketPart# 45042

#10-32 x 5/8" ScrewPart# 94144Securing Luminaire Jointsp. 9, Step 6

A. Identify Luminaires B. Remove Diffuser

Kitted Hardware

• Identify all luminaires by their ID label that can be found on the box, on the diffuser, and inside the luminaire. • NOTE: Exact location of labels in these areas may vary. • Remove all luminaires from their box.• Refer to Record Drawings that can be found in the hardware kit.

HP-6 VF - 8'

ABC Corporation - A12345HP-6-VF - 32' - S - 835 - F - 120V - SC - C1 - OBO

STARTER ID: 1 HP-6 VF - 16'

ABC Corporation - A12345HP-6-VF - 32' - S - 835 - F - 120V - SC - C1 - OBO

JOINER ID: 2 HP-6 VF - 23'

ABC Corporation - A12345HP-6-VF - 32' - S - 835 - F - 120V - SC - C1 - OBO

ENDER ID: 3

ABC Corporation - A12345

HP-4 WW-R - K - 32' - S - 835 - 120V - SC - C1

HP-4 WW-R - VF - X'ID: 1

STARTER

Lorem ipsumFactory Order NumberJob Name

Unique LuminaireID Number

Full Catalog Order ID

Luminaire Section Type

Luminaire Type and/or Run Length

• Finelite has provided items listed here, with their Finelite part numbers. These items can be found in separate boxes shipped with the luminaire.

• Account for all parts and set aside until they are needed.

• All other hardware needed for this installation will be by others.

Mud Guard

Diffuser

ID Label

HP-2

Kicker

Diffuser

1

2

Backplate

Putty Knife

• 1. Slide putty knife between the backplate and diffuser. • 2. Carefully separate diffuser from the backplate, keeping it inside its protective bag.• Set aside all diffusers to prevent from getting dirty or damaged.• Ensure diffuser can be clearly identified back to its corresponding luminaire.• CAUTION (Spackle Flange Only): Carefully remove Mud Guards and keep them as

they will be reinstalled in Step 7C.

• 1. Push bottom edge of the diffuser into backplate. • 2. Slide diffuser out of backplate.• Carefully remove and set aside all diffusers to prevent from getting dirty

or damaged.• Ensure diffuser can be clearly identified back to its corresponding luminaire.• CAUTION (Spackle Flange Only): Carefully remove Mud Guards and keep

them as they will be reinstalled in Step 7C.

Kicker

Diffuser

1

2

HP-4

Step 2 - Identification & Preparation

5 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

Step 3 - Opening Luminaires

#8-18 x 1/4" Screw(provided)

A. Release Backplates B. Remove Backplates

Backplate

1/4" Washer(provided)

• NOTE: If installing an independent, leave backplate installed and PROCEED TO STEP 4.• Release backplate from luminaire body by removing the #8-18 x 1/4" screw and

1/4" washer from both ends of the luminaire.• CAUTION: Set these screws and washers aside. Do not lose.

• NOTE: If installing an independent, leave backplate installed and PROCEED TO STEP 4.• Release backplate from luminaire body by removing the #8-18 x 1/4" screw from both

ends of the luminaire.• CAUTION: Set these screws aside. Do not lose.

#8-18 x 1/4" Screw (provided)

HP-4HP-2

#8-18 x 1/4" Screw (provided) 1/4" Washer (provided)

• Remove backplates by rotating then lifting up and out of the luminaire body.

• Keep backplate hanging with safety cables connected.

• Remove backplates by rotating then lifting up and out of the luminaire body.

• Keep backplate hanging with safety cables connected.

Backplate

HP-4HP-2

WALL SIDE

6 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

Step 4 - Mounting Starter to Structure

Jam Nut

Jam Nut

Splice Box

Conduit Plate

#8 Screw

Conduit Plate#8 Screw

Jam Nut

Conduit Plate

Starter

Conduit

CONTINUED

CONDUIT PLATE - ENDCAP (Standard)• Remove two screws holding conduit plate.• Install conduit and jam nut onto conduit plate.• Wire-nut electrical connections. See wiring legend above.• Reinstall conduit plate and screws. Do not damage any wires.

CONDUIT PLATE - TOP (Optional: HP-4 Only)• Remove screw holding conduit plate.• Install conduit and nut onto conduit plate.• Wire-nut electrical connections. See wiring legend above.• Reinstall conduit plate and screw. Do not damage any wires.

SPLICE BOX (Optional)• Lift tab to unsnap and remove splice box cover.• Install conduit and nut onto splice box cover.• Wire-nut electrical connections. See wiring legend above.• Reinstall splice box cover. Do not damage any wires.

Wire-nut electrical connections.

(Typical for all options.)WIRING LEGEND

Black Hot Line Voltage

White Neutral Line Voltage

Green Ground

Pink Dimming 0-10V DC

Purple Dimming 0-10V DC

A. Make Electrical Connections Electrical Connection Options

Flex Conduit(by others)

0-10V Dimming

• While properly supporting luminaire, maneuver luminaire near wall/ceiling opening.

• Make electrical connections at ENDCAP, at TOP or with a SPLICE BOX.

7 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

1/4" Washer(by others)

1/4"-20 Nut(by others)

Threaded Rod(by others)

Option 1 (Shown) - Mount to Threaded Rod• Align threaded rods with mounting holes and slide luminaire into wall/ceiling.• Install 1/4"-20 nut and 1/4" washer onto 1/4"-20 threaded rod.• CRITICAL: If installing a joiner luminaire in the next step, leave the nut loose,

allowing the luminaire to hang out of ceiling at an angle.• If there is no joiner/ender, then tighten nuts fully. PROCEED TO STEP 7.

Option 2 - Mount to Structure• Slide luminaire into wall/ceiling and mount to structure support with hardware

appropriate for the structure type.• CRITICAL: If installing a joiner luminaire in the next step, leave the bolt/screw

loose, allowing luminaire to hang out of ceiling at an angle.• If there is no joiner/ender, then tighten nuts fully. PROCEED TO STEP 7.

B. Mount Starter to Structure

Ceiling

Starter

1/4"-20 Threaded Rod (by others)

Drywall Ceiling Drywall Ceiling

Drywall Ceiling Drywall Ceiling

Option 1 (Shown) - Mount to Threaded Rod

Option 2 - Mount to Structure

1/4"-20 Lag Bolt(by others)

SupportBlocking(by others)

SupportBlocking(by others)

SupportBlocking

(by others)

SupportBlocking

(by others)

Structure Support (by others)

1/4"-20 Lag Bolt(by others)

Mounting Option 2Mounting Option 1

1/4"-20 Threaded Rod (by others)

1/4" Washer (by others)

1/4"-20 Nut (by others)

Step 4 - Mounting Starter to Structure

8 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

Option 1 (Shown) - Mount to Threaded Rod Option 2 - Mount to Structure

• Align joiner/ender with aligner sleeves on starter and slide together. Be careful not to damage any wiring.

• If necessary, lift both luminaires, then slide together.

B. Join Luminaires

Joiner/Ender

Starter

Aligner Sleeve

A. Mount Joiner/Ender to Structure

StarterJoiner/Ender

Ceiling

• Align threaded rods with mounting holes and slide luminaire into wall/ceiling.• Install 1/4"-20 nut and 1/4" washer onto 1/4"-20 threaded rod.• CRITICAL: If installing a joiner luminaire in the next step, leave the nut loose,

allowing the luminaire to hang out of ceiling at an angle.

• Slide luminaire into wall/ceiling and mount to structure support with hardware appropriate for the structure type.

• CRITICAL: If installing a joiner luminaire in the next step, leave the bolt/screw loose, allowing luminaire to hang out of ceiling at an angle.

CAUTION

DO NOT attempt to join luminaires together on the floor. Damage may result when lifted. Follow these instructions.

1/4" Washer(by others)

1/4"-20 Nut(by others)

Threaded Rod(by others)

1/4"-20 Lag Bolt(by others)

Mounting Option 2Mounting Option 1

Step 5 - Joining Luminaires

• While properly supporting luminaire, maneuver luminaire near wall/ceiling opening.• If necessary, loosen bolts on previous luminaire so that it can hang out of the opening at an angle.• After installing a joiner, return to previous luminaire and tighten.

9 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

SimplePlug-Together

Wiring

Universal &Robust Joints

Joiner/Ender

Starter

Yoke Screw (provided)

Aligner Sleeve

Yoke Bracket (provided)

1 Screwdriver with 6" bit required.

Yoke Bracket w/ Screw#10-32 x 5/8" (provided)

B. Make Electrical Connections A. Secure Joint with Yoke Brackets IN ALIGNMENT CORRECTLY INSTALLED

• Before installing yoke brackets, ensure the joining ends of luminaires meet flush and square.• CRITICAL: Ensure yoke brackets properly engage with aligner sleeves.• Secure joint by threading (but not yet tightening) yoke screws through yoke brackets and

into the aligner sleeves.• Tighten yoke screws¹ until joint seam of luminaires is closed.• Fully secure luminaire to structure by fully tightening the 1/4-20 nuts or lag bolts.

Luminaire Joint Luminaire Joint

YESNO

YOKE SCREW ALIGNMENT Bottom-Up View

Cross SectionView

Joiner/Ender

Starter

Plug-Together Wiring

Joiner/Ender Aligner Sleeve

Joiner/Ender Aligner SleeveLuminaire Joint

NOTE: Yoke screws should be installed directly across from each other, not diagonally, and in holes furthest from the joint line. One yoke screw per one yoke bracket. • Connect plug-together wiring.

Step 6 - Securing Luminaire Joints

10 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

Step 7 - Closing Luminaires

CONTINUED

#10 x 1/2" Screw(provided)

#8-18 x 1/4" Screw(provided)

1/4" Washer(provided)

A. Replace Backplates

HP-4HP-2

• 1. Carefully reinstall backplate into luminaire by inserting and rotating. • 2. Install joint cover plate by inserting into backplate and installing two #8-18 x 1/4"

screws at the joint. PROCEED TO STEP 7C

Joint Cover Plate

2

Joint Cover Plate

WALL SIDE

Backplate

1

Backplate

• 1. Carefully reinstall backplate into luminaire by inserting and rotating. • 2. Install 1/4" washer and #8-18 x 1/4" screw to backplate at both ends of luminaire.

1 2

Backplate

B. Secure Joint with #10 x 1/2" Screws

• Install 1/4" washers and #10 x 1/2" screws at the joint.

HP-4 Only

#8-18 x 1/4" Screw (provided)

1/4" Washer (provided)#10 x 1/2" Screw (provided)

1/4" Washer (provided)

11 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

Step 7 - Closing Luminaires

C. Secure Flange To Structure D. Apply Spackle

• Secure flanges to wall/ceiling using appropriate screws or fasteners1 for hard surface, per local building codes.• Install the "mud guard" cardboard inserts to help prevent spackle and paint from getting into the luminaire.

• Spackle and paint over flanges up to luminaire edge.• CAUTION: Careful not to drop spackle into luminaire. Immediately wipe off excess spackle that may have gotten onto luminaire edges.• Perform all spackling and painting to walls and ceiling prior to removing mud guards.• Remove all mud guards.

Every 6" to 12"

Mud Guard (provided)

Mud Guard (provided)

Putty Knife

Spackle

Ceiling

Ceiling

WallWall

Spackle Flange Only Spackle Flange Only

1 Screws or fasteners: drywall - drywall screws, wood - wood screws, etc.

Screw/Fastener(by others)

CONTINUED

Screw (by others)

12 of 12

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions©

2021 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98551 V3 EFFECTIVE DATE: 09/21

ID: 1

ID: 1

ID: 2

ID: 2

ID: 3

ID: 3

E. Final Step - Replace Diffusers

• NOTE: If your installation includes a battery backup, please see addendum (98333) that should be included with your kitting package.• Remove diffusers from protective plastic bag.• CAUTION: Wear gloves to keep diffuser surface clean.• CRITICAL: Be sure to install correct diffuser to its corresponding luminaire ID.• Install diffusers into luminaire body, ensuring they are in place.• 1. Reinstall diffusers by pushing right side of the diffuser into the backplate.• 2. Push the left side of diffuser until it lays flat on the backplate.• Turn power on to luminaire.

1

2

HP-4

• NOTE: If your installation includes a battery backup, please see addendum (98333) that should be included with your kitting package.• Remove diffusers from protective plastic bag.• CAUTION: Wear gloves to keep diffuser surface clean.• CRITICAL: Be sure to install correct diffuser to its corresponding luminaire ID.• Install diffusers into luminaire body, ensuring they are in place.• 1. Slide the side of the diffuser without a notch into the luminaire.• 2. Push the side of the diffuser that has a notch until click sound is heard.• Turn power on to luminaire.

HP-2

12

Step 7 - Closing Luminaires