Host utility Host company
Staying ahead of their
Progressive Customer Base:
How Fort Collins is taking steps
to modernize their electric grid
![Page 2: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/2.jpg)
Copyright © 2013 eMeter, A Siemens Business. All rights reserved.
Dennis Sumner Advanced Meter Fort Collins
Project Manager
Senior Electrical Engineer City of Fort Collins
![Page 4: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/4.jpg)
AMFC: Overview
Background
Highlights
Schedule
Issues
Partners
Discussion
![Page 5: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/5.jpg)
AMFC: Overview
Background
Highlights
Schedule
Issues
Partners
Discussion
![Page 6: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/6.jpg)
Reducing Local Greenhouse Gas Emissions
Fort Collins is a national leader in reducing local
greenhouse (GHG) emissions.
City Council policies support GHG reduction goals.
• 2008 Climate Action Plan
• 2009 Energy Policy
Policy helps advance economic and environmental
sustainability.
6
![Page 7: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/7.jpg)
City Council Goals
2008 Climate Action Plan
Green House Gases - 2005 base levels:
• 20% reduction by 2020
• 80% reduction by 2050
Advanced Metering first proposed in Climate
Action Plan
7
![Page 8: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/8.jpg)
City Council Goals
City of Fort Collins Energy Policy
1.5% energy savings
System peak reduction goals
• 2015: 5%
• 2020: 10%
Highly reliable electric service
Renewable resources to meet the
Colorado Renewable Energy Standard
8
![Page 9: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/9.jpg)
Highly Reliable Service
12 month period ending September 2012:
Electric system was available to customers an average of 99.9967% of the time
Goal: 99.9956%
Customers experienced an average service interruption of 41 minutes
Goal: 45 minutes
Customers experienced an average system outage frequency of 0.42
Goal: 0.66
9
![Page 10: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/10.jpg)
AMFC: Overview
Background
Highlights
Schedule
Issues
Partners
Discussion
![Page 11: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/11.jpg)
Scope
$36M total cost,
Electric: $32M
• $16M : Department of Energy –
Smart Grid Investment Grant (SGIG)
Water: $4M
11-year payback
Device installations early 2012
through mid-2013
11
![Page 12: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/12.jpg)
Equipment
AMI Infrastructure
• Electric Metering
• Water Metering Modules
• Communications
• Distribution Automation
12
![Page 13: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/13.jpg)
Metering & Communications
Enhanced Cyber Security
13
![Page 14: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/14.jpg)
Distribution Automation
Fault Indicators
Remotely operated
switchgear
Power Quality Monitoring
14
![Page 15: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/15.jpg)
Customer Engagement
Web Portal
Mobile Platform
Demand Response
Management System
(DRMS)
15
![Page 16: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/16.jpg)
Customer Dashboard
Billing Comparison
Bill Analysis
Energy & Water Management
Rate Comparison
Consumer Alerts
Targeted models for reducing
use
Online bill pay
Customer Web Portal
![Page 17: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/17.jpg)
Mobile Platform
Account Status
Bill Summary
Bill-to-Date
Cost Alerts
• Water & Electric Tiered
rates and TOU alerts
Demand Response
Participation Notifications
• Opt-in or Opt-out
![Page 18: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/18.jpg)
AMFC: Web Portal Success Factors
Customer Use of
Portal
Enhanced Customer
Service
Customer Satisfaction
Energy/Water :
Reduce Use & Carbon
![Page 19: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/19.jpg)
AMFC: Overview
Background
Highlights
Schedule
Issues
Partners
Discussion
![Page 20: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/20.jpg)
Template
Template
Template
![Page 21: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/21.jpg)
AMFC: Overview
Background
Highlights
Schedule
Issues
Partners
Discussion
![Page 22: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/22.jpg)
Fort Collins, Colorado
Issues: Customer Concerns
• Cost
• Privacy
• Health
Customer Options
AMFC
![Page 23: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/23.jpg)
23
Cost
11-year payback
Enhanced customer data - better customer decision making
Enhanced operations data – better operations & Planning
Remote outage notification speeds repair and reduces vehicle trips.
![Page 24: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/24.jpg)
Privacy
Utilities adheres to strict policies to protect customer information. • Federal: “Red Flags Rules of the FACT Act”
• Colorado Open Records Act
• internal policies
Security • Detailed and confidential
cyber security plan adopted.
24
![Page 25: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/25.jpg)
Health:
Radio Frequency Exposure Levels*
25
Source Notes: Electric Power Research Institute (EPRI)
“Radio Frequency Exposure Levels from Smart Meters:
A Case Study of One Model”
(1) Based on a 3-inch, 250 mW antenna emitting in a cylindrical wavefront.
(2) ICNIRP. 2009. “Exposure to high frequency electromagnetic fields,
biological effects and health consequences (100 kHz-300 GHz).”
International Commission on Non-Ionizing Radiation Protection,
Oberschleißheim, Germany, page 21.
Tell RA. 1978. Field-strength measurements of microwave-oven leakage
at 915 MHz. IEEE Trans Electromagnetic Compatibility 20:341-346.
R.A. Tell, personal communication.
(3) Wireless router based on 30-100 mW isotropic emitter.
(4) Tell RA, Mantiply ED. 1980. Population Exposure to VHF and UHF
Broadcast Radiation in the United States. Proc IEEE 68:6-12.
(5) Based on spatial peak power density with 6 dB (x4) antenna gain.
Maximum values are based on 5% duty cycle and 1W broadcast power.
Minimum values are based on 1% duty cycle and 250mW broadcast power.
For instantaneous power density during transmission, multiply the number
for minimum values by 100, and the number for maximum values by 20.
*All values are shown in milliwatts per square centimeter (mW/cm2).
![Page 26: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/26.jpg)
Radio Frequency Exposure Levels
&
Source Notes
26
Notes:
Source: Electric Power Research Institute (EPRI) – “Radio Frequency
Exposure Levels from Smart Meters: A Case Study of One Model”
(1) Based on a 3-inch, 250 mW antenna emitting in a cylindrical wavefront.
(2) ICNIRP. 2009. “Exposure to high frequency electromagnetic fields, biological effects
and health consequences (100 kHz-300 GHz).” International Commission on
Non-Ionizing Radiation Protection, Oberschleißheim, Germany, page 21. Tell RA. 1978.
Field-strength measurements of microwave-oven leakage at 915 MHz. IEEE Trans
Electromagnetic Compatibility 20:341-346. R.A. Tell, personal communication.
(3) Wireless router based on 30-100 mW isotropic emitter.
(4) Tell RA, Mantiply ED. 1980. Population Exposure to VHF and UHF Broadcast
Radiation in the United States. Proc IEEE 68:6-12.
(5) Based on spatial peak power density with 6 dB (x4) antenna gain.
Maximum values are based on 5% duty cycle and 1W broadcast power. Minimum values
are based on 1% duty cycle and 250mW broadcast power. For instantaneous power
density during transmission, multiply the number for minimum values by 100, and the
number for maximum values by 20.
![Page 27: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/27.jpg)
3.5
Years
68
Days
1.7
Years 19
Years
32
Years
4 2
Note: Signal is reduced by
meter socket and wall
Cell phone exposure:
- 5 Minutes at 1 cm from ear
- 0.013816 mW / cm2
1) Values calculated by FCU for meter RF power density are shown in mW/cm2, and are calculated
based on 0.1% transmit duty cycle (86 seconds per day) and 250mW transmit power.
2) Cell phone 50mW transmit power based on FCC data for HTC Thunderbolt smart phone.
Radio Frequency (RF) Exposure Comparison:
Time-averaged RF exposure AMI meter & one cellular Phone Call
![Page 28: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/28.jpg)
Customer Options
Customer Option 1
• Standard Mode
Options to address areas of customer concern
Customer Option 2
• Limited Mode Customer Option 3
• Manual Mode
![Page 29: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/29.jpg)
Customer Options Summary
Considerations
Option 1 Standard
Option 2 Limited
Option 3 Manual
Functionality and ability to take advantage of new technology; allows full customer benefits
High Limited Minimal
Data collected in 15-minute to one-hour intervals
Data collected once per day
Data collected once per month via manual read
Data transmitted 4 to 6 times per day via a 1.5 second signal
Additional customer cost
Additional system cost Requires monthly service call
Ability to support Energy Policy High Limited Minimal
![Page 30: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/30.jpg)
AMFC: Overview
Background
Highlights
Schedule
Issues
Partners
Discussion
![Page 31: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/31.jpg)
AMFC: Partners
Excergy:
• PM & Technical Support
Elster:
• Metering & Communications
(Tropos)
Corix: Deployment
Siemens: MDMS (eMeter)
Aclara:
• Web Portal, DRMS (Calico) &
Authentication (Smart Grid CIS)
![Page 32: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/32.jpg)
AMFC: Overview
Background
Highlights
Schedule
Issues
Partners
Discussion
![Page 33: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/33.jpg)
Discussion
Fort Collins AMFC Project Lead Team
33
Steve Catanach: Light & Power Operations Manager
Lisa Rosintoski: Utilities Customer Connections Manager
Kraig Bader: Standards Engineering Manager
Mary Evans: Utilities MIS Applications Services Manager
Angel Anderson: Web Portal Project Manager
Judy Dahlgren: Deployment Project Manager
Jim Ketchledge: Excergy - Project Manager
Dennis Sumner: AMFC Project Manager
QUESTIONS: [email protected]
![Page 34: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/34.jpg)
Talk More about Deployment
Judy Dahlgren
![Page 35: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/35.jpg)
Discussion: Deployment Facts
65,000 electric meters
33,000 water modules
55 sq.+ miles service
territory area
35
![Page 36: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/36.jpg)
Discussion: Mass Deployment Planning
Followed Installed
Communication Infrastructure
Contiguous deployment –
clockwise path
Immediate Cutover
36
![Page 37: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/37.jpg)
Discussion: Mass Deployment
Corix Utilities hired as
end point installer
Mass Deployment began
in Sept. 2012
12 electric & 12 water
installers
36,000+ electric installed
20,000+ water installed
37
![Page 38: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/38.jpg)
Deployment: Elements of Success
Developed plan with all impacted
parties input
Communicate early and often
Offer Options – rates not punitive
AMI Vendor – Elster added meter
functionality
38
![Page 39: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/39.jpg)
Deployment: Lessons Learned
Phase 1 Deployment: Initial Deployment Area
Flexibility: bugs & firmware updates – deployment modifications
Customer Communications is critical
• Response to customer calls
• SharePoint utilized as tracking tool
• Executive Team involvement
• Mitigated issues early
Regular status and coordination with billing team essential
Outliers - case by case, focus on Mass Deployment
39
![Page 40: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/40.jpg)
Discussion
Fort Collins AMFC Project Lead Team
40
Steve Catanach: Light & Power Operations Manager
Lisa Rosintoski: Utilities Customer Connections Manager
Kraig Bader: Standards Engineering Manager
Mary Evans: Utilities MIS Applications Services Manager
Angel Anderson: Web Portal Project Manager
Judy Dahlgren: Deployment Project Manager
Jim Ketchledge: Excergy - Project Manager
Dennis Sumner: AMFC Project Manager
QUESTIONS: [email protected]
![Page 42: How Fort Collins is taking steps to modernize their electric grid](https://reader033.vdocuments.site/reader033/viewer/2022060119/558cc294d8b42a061a8b4669/html5/thumbnails/42.jpg)
Copyright © 2013 eMeter, A Siemens Business. All rights reserved.
Host utility
Dennis Sumner
Host company
Questions?