house wiring (domestic wiring)
TRANSCRIPT
Basic Domestic WiringA Presentation on
Contents
Introduction
Types Wiring system
Types of wire
I.E. rule for wiring.
Domestic wiring panel
Conclusion
Introduction:• Wiring is electric circuit.
• Wiring is systematic laying of wires for the smooth flowing of electricity current at different utility places with utmost safety and precautions.
Types of wirings:Chapter no. : 1
TYPESOf
WIRINGBATTERN
PVC wiring
TRS/CTS wiring
Lead sheath wiring
CLEAT
CASING CAPING
CONDUIT
Surface conduit
Concealed conduit
Conduit wiring
Surface conduit wiring
Metal conduit
P.V.C. conduit
Concealed conduit wiring
Metal conduit
P.V.C. conduit
Cleat wiring:
•It fit on the wall.•Distance of half meter between two cleat.•Vulcanized Indian rubber wire used.•Temporary used.•Wire are in the open atmosphere.
Wooden casing capping wiring:
•It fit on the wall with help of screw.•It protect wire against mechanical damage, Moisture, dust.
PVC casing capping wiring:
•It become popular,•Less cost,•Easily fault detect•Appearance of wiring is good,
Surface conduit wiring:
•PVC, or metallic conduit are used.•PVC, VIR wire are used.•Appearance is good.•It protect wire against mechanical damage, Moisture, dust.
Concealed conduit wiring:
•PVC, or metallic conduit are used Conduit inside the wall•Appearance is good•Protect against fire dust moisture mechanical damage,•Less maintenance•Less chance of Fault•Cost is high
Concealed conduit wiring
Types of wire used in domestic wiring
Chapter no. : 2
Types of
wire
V.I.R. wire
C.T.S./T.R.S. WIRE
Weather proof wire
Lead covered
wire
MICC wire
PVCwire
Vulcanized Rubber wire
Weather proof wire
•It made waterproof by drooping it into waterproof compound•It is useful for service connection
Lead covered wire
•No effect of moisture on it•It used where there is moisture presence.
Mineral insulated copper covered:
•Coating of magnesium oxide is provided.•Less effect of temperature.•Copper sheath is provided.•It is used in mines, factory, refinery, furnace, boiler, rolling, mill est.
Poly Vinyl Chloride wire:
•Dielectric strength is more•Mechanical strength is more•Life is long•Protect against flame•Protect against oil, alkali•PVC wire is widely used
General rules for domestic wiring:
Chapter no. : 3
1. General rules of domestic wiring.
1. Cut-out on consumer’s premises.
2. Meters, maximum demand indicators and other apparatus on consumer Premises.
3. Weatherproof wire for service connection with sufficient current carrying capacity.
6. All conductor/wire should be sage in all term of voltage rating with proper insulation.
7. Ever line or phase should be protected by suitable ratings fuse.
8. In metal conduit wiring metal conduit pipe continuously earthed.
9. Each load point an appliances should be a independent control switch.
10. In any building. the wiring installation, there must be separate sub circuits for light/fan/3 pin socket load and for 3 pin socket 15 Amp. power load.
11. In any light/fan and the number of load points connected in one sub circuit should be less than 10(ten).
13. In any power sub circuit, the maximum should not be more than 3000 watts and the number of power point should be up to two only. 14.The rating of fuse in any circuit should not be less than half the capacity of the lowest size cable. In any sub-circuit the fuse rating should not be more than 5 amp.
15. The earthed terminals of all 3 pin sockets outlets and plugs should be permanently connected to the earth wire.. 16. Sufficient number of 3 pin socket outlets should be provided at suitable places in all rooms of the building
17. In the bath rooms. the 3 pin socket should be at a height of not less than 1.5 m.
18. All ceiling fans are to be hung 2.75 m above the floor level refer IS :4648 -1968.
19. In the domestic wiring earth wire should be of 14 SWG GI for single phase supply and for 3 phase supply system earth wire must be of 8 SwG GI.
20. If the load on any domestic wiring installation exceeds 6.0 kw. then 3 415 v. 50 Hz, 4 wire supply should be used. The load on 3 phases should be properly balanced.
21. when the covered area in the building complex is more than 5000 m2 and the total load is more than 1000kva. The separate sub station is required to be installed.
Domestic wiring panel:Chapter no. : 4
Single line diagram of electrical Installation
Line Diagram of Service line to Main Switch connection
Single Phase 2-wire line diagram
3-phase, 2-wire, load up to 6kw
Plan Layout of Electric Installation.
Reference:
• http://www.electrical-engineering-assignment.com/electric-supply-system-a-c
• Electrical wiring estimation coasting cotracting (by P.M. soni ) Pub. By Atul Prakashan
Conclusion
After study the basic introduction of Domestic wiring. We can conclude about the types of wiring, types of wire, line diagram of wiring ,main switch panel ect.
THANKYOU