HOMEPRO RESIDENTIAL INSPECTION REPORT
1408 16th Ave NWRochester MN 55901
David KemperAUGUST 19, 2020
InspectorRick Erickson
InterNACHI Certified Home Inspector507-202-8942
All definitions listed below refer to the property or item listed as inspected on thisreport at the time of inspection.
Acceptable - Item is functional with no obvious signs of defect.
Positive Attribute - Items that are considered a positive attribute to the property
Maintenance - Item is functional but due to normal wear and tear requiresmaintenance repair or servicing. Item not present or not found.
Repairs Recommended - Item is worn, unsafe, damaged, non functional and warrantsrepairs or replacement
Not Present - Item was not present at the time of the inspection
Not Inspected - Item was unable to be inspected for safety reasons or due to lack ofpower, inaccessible, or disconnected at time of inspection.
1408 16th Ave NW David Kemper
Homepro Inspections Page 2 of 26
7.2.1 Plumbing - Water Lines : Water valve leaking
10.5.1 Electrical - Wiring Notes : 3-prong outlets did not test properly, Open ground
10.5.2 Electrical - Wiring Notes : Hot/neutral reversed
10.5.3 Electrical - Wiring Notes : Improper splice not within a junction box
10.5.4 Electrical - Wiring Notes : Loose light fixture
10.6.1 Electrical - GFCI's : Recommend GFCIs
11.3.1 Interior - Windows : Glazing/caulking deteriorated
11.6.1 Interior - Floors : Potential asbestos in linoleum flooring
12.3.1 Fireplace - Vent System : Bricks have broken or popped surfaces
17.1.1 Garage - Detached - Exterior Walls : Slight bow at top of wall structure - cables/turnbuckles support
17.2.1 Garage - Detached - Roof: Roofing materials at/near end of useful lifespan
17.3.1 Garage - Detached - Trim, Soffit, Eaves : Trim materials at or near end of lifespan
17.8.1 Garage - Detached - Sheathing : Old dry moisture stains present
17.11.1 Garage - Detached - Floor/Foundation: Surface raised/settled
17.11.2 Garage - Detached - Floor/Foundation: Recommend further evaluation for structural integrity
17.12.1 Garage - Detached - Service Door: Threshold damaged/missing
17.14.1 Garage - Detached - Door Opener : Recommend adjusting auto reverse down pressure
17.15.1 Garage - Detached - Electrical Panel : Openings in the panel should be covered
17.18.1 Garage - Detached - GFCI's : Recommend GFCIs
SUMMARY
1408 16th Ave NW David Kemper
Homepro Inspections Page 3 of 26
Property Address
1408 16th Ave NW, RochesterMN 55901
Client Name
David Kemper
Agent Name
Weather ConditionsSunny
TemperatureMid 70's
Utilities OnYes
Building TypeSingle family, Garage Detached
Start Time:11:15
Stop Time:12:40
1: GENERAL INFORMATION
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 4 of 26
Grading : DescriptionLevel Site, Moderate slope
Driveway : DescriptionConcrete, Common cracks,Surface raised or settled
Sidewalks : DescriptionConcrete, Common cracks,Surface raised or settled
Patio : DescriptionConcrete, Common Cracks,Surface raised or settled
Fences & Gates : DescriptionChain link
2: GROUNDS
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 5 of 26
Exterior Walls : DescriptionWood frame, Metal siding,Common cracks
Trim, Soffit, Eaves : DescriptionWood, Metal, Common cracks
Stairs/Steps : DescriptionConcrete, Common cracks,Stair/hand railing acceptable
3: EXTERIOR
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 6 of 26
Foundation: DescriptionMasonry Block, Concrete floor,Common cracks, Full basement
Foundation: Basement SpacePartially finished
Structure/Support: DescriptionJoists, Beam and posts, Commoncracks
Reference
Radon Mitigation : DescriptionActive radon system, Monometerpresent
4: FOUNDATION
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 7 of 26
General : DescriptionHip, Composition shingle
General : Method of inspectionWalking roof
General : Number of Layers1
Flashings : DescriptionMetal
Plumbing Vents : DescriptionCast Iron
Gutters/Downspouts :Description
Metal, Fully Installed
5: ROOF
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 8 of 26
DescriptionCloset
Method of InspectionInspection limited to view fromaccess
Roof Framing : DescriptionRafter
Sheathing : DescriptionDimensional wood
Insulation/Vapor Barrier :Description
Fiberglass batt, Cellulose blown,Vermiculite, Potential asbestos atvermiculite insulation
Insulation/Vapor Barrier :Insulation depth - approximate
~4 - 6 inches
Ventilation : DescriptionRoof and soffit vents
6: ATTIC
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 9 of 26
Main Water Shutoff : DescriptionBasement, Utility room
Main Water Shutoff : City water Water Lines : DescriptionCopper
Waste Lines : DescriptionGalvanized, Cast Iron
Waste Lines : City sewer Hose Faucets: DescriptionAnti-frost
Gas Fuel System: Fuel typeNatural Gas
Gas Fuel System: Gas meterlocation
Front
Gas Fuel System: Main valvelocation
Gas meter
Gas Fuel System: Gas servicelines
CSST, Black pipe
Water Heater: DescriptionStorage, Natural gas, 40 gallon,TPRV acceptable
Water Heater: LocationBasement, Utility room
7: PLUMBING
Information
Observations
7.2.1 Water LinesWATER VALVE LEAKINGRecommendationContact a qualified plumbing contractor.
Repair Recommendation
1408 16th Ave NW David Kemper
Homepro Inspections Page 10 of 26
Heating System : DescriptionForced air, Natural gas
Heating System : LocationBasement, Utility room
Heating System : Age2001 Years
Vent System : DescriptionWall direct vent - PVC
Air Filter : DescriptionStandard filter
Distribution : DescriptionDucts and registers
Thermostats : DescriptionIndividual, Programmable
8: HEATING
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 11 of 26
A/C System: DescriptionCentral air conditioning
A/C System: LocationRear
A/C System: Refrigerant LinesFoam
A/C System: ElectricalDisconnect
Tumble switch
9: AIR CONDITIONING
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 12 of 26
Service Type : DescriptionOverhead
Service Type : Volts240 Volts A/C
Electrical Panel : LocationBasement
Electrical Panel : Amperage150 Amps
Electrical Panel : OvercurrentDevice
Breakers
Conductors : DescriptionService wire aluminum, Branchwire copper, Non-metalicsheathed cable
Door Bell : Doorbell respondedto test
Wiring Notes : Representativenumber of outlets and fixturestested
10: ELECTRICAL
Information
Observations
10.5.1 Wiring Notes3-PRONG OUTLETS DID NOT TEST PROPERLY, OPEN GROUNDMULTIPLE LOCATIONSRecommendationContact a qualified electrical contractor.
Repair Recommendation
10.5.2 Wiring NotesHOT/NEUTRAL REVERSEDRecommendationContact a qualified electrical contractor.
Repair Recommendation
10.5.3 Wiring NotesIMPROPER SPLICE NOT WITHIN A JUNCTION BOXRecommendationContact a qualified professional.
Repair Recommendation
1408 16th Ave NW David Kemper
Homepro Inspections Page 13 of 26
10.5.4 Wiring NotesLOOSE LIGHT FIXTURERecommendationContact a qualified handyman.
Repair Recommendation
10.6.1 GFCI'sRECOMMEND GFCISKITCHEN, EXTERIOR, UNFINISHED BASEMENT SPACERecommendationContact a qualified electrical contractor.
Repair Recommendation
1408 16th Ave NW David Kemper
Homepro Inspections Page 14 of 26
Entry/Exterior Doors: Doorhardware acceptable
Interior Doors : Door hardwareacceptable
Windows : TypeDouble hung, Wood
Interior Walls : DescriptionPlaster, Common cracks
Ceilings: DescriptionPlaster, Common cracks
Floors : DescriptionCarpet, Wood, Tile, Linoleum
Interior Stairs: Handrails appearacceptable
Ceiling Fans : Responded tocontrols
Smoke Detector : Located atBedrooms, Every level
C/O Detector : Located within 10feet of sleeping area, on eachlevel
11: INTERIOR
Information
Observations
11.3.1 WindowsGLAZING/CAULKING DETERIORATEDRecommendationContact a handyman or DIY project
Maintenance Item
11.6.1 FloorsPOTENTIAL ASBESTOS IN LINOLEUMFLOORINGRecommendationContact a qualified professional.
Maintenance Item
1408 16th Ave NW David Kemper
Homepro Inspections Page 15 of 26
1408 16th Ave NW David Kemper
Homepro Inspections Page 16 of 26
General: DescriptionWood fired
General: LocationLiving room
Burn Chamber : DescriptionMetal
Vent System : DescriptionMetal flue, Brick chase
Doors/Screens: DescriptionGlass
Hearth : Descriptionstone
12: FIREPLACE
Information
Observations
12.3.1 Vent SystemBRICKS HAVE BROKEN ORPOPPED SURFACESRecommendationContact a qualified masonry professional.
Repair Recommendation
1408 16th Ave NW David Kemper
Homepro Inspections Page 17 of 26
General: LocationMain, Full
Toilet : Flush/plumbingacceptable
Sink/Cabinet : Faucet/plumbingunder sink acceptable
Bathtub : Faucet/drainacceptable
Shower : Faucet, drainacceptable
Exhaust: DescriptionExhaust fan
13: BATHROOM - MAIN
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 18 of 26
General: LocationLower, 3/4
Toilet : Flush/plumbingacceptable
Sink/Cabinet : Faucet/plumbingunder sink acceptable
Shower : Faucet, drainacceptable
Exhaust: DescriptionExhaust fan
14: BATHROOM - LOWER
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 19 of 26
Counter/Cabinets: DescriptionLaminate, Wood cabinets
Sink/Fixtures/Disposal :Description
Faucet acceptable, Plumbingunder sink acceptable, Garbagedisposal responded to test
Appliances: Range/OvenRange Gas, Oven Electric, Doorseal acceptable
Appliances: Refrigerator/FreezerDoor seal acceptable
Appliances: DishwasherDoor seal acceptable
Appliances: Exhaust VentVents to exterior
15: KITCHEN
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 20 of 26
LocationBasement
Washer/Dryer : Description240 volt outlet present
Dryer Vent : DescriptionRigid metal
16: LAUNDRY
Information
1408 16th Ave NW David Kemper
Homepro Inspections Page 21 of 26
Exterior Walls : DescriptionWood frame, Metal siding,Common cracks
Roof: DescriptionGable
Roof: Method of inspectionViewing from eaves
Roof: Number of Layers1
Trim, Soffit, Eaves : DescriptionWood, Metal, Common cracks
Method of InspectionViewed from floor
Gutters/Downspouts :Description
Not present
Roof Framing : DescriptionRafter
Roof Framing : Note:
Reinforcement added to existingstructure
Sheathing : DescriptionDimensional wood
Floor/Foundation: Description -Floor
Concrete, Common Cracks
Floor/Foundation: Description -Foundation
Masonry Block, Common cracks
Service Door: DescriptionMetal
Vehicle Door : DescriptionRoll Up
Door Opener : SafetyElectric eye beam responds totest
Electrical Panel : Locationgarage
Electrical Panel : AmperageSub-panel
Electrical Panel : OvercurrentDevice
Breakers
Conductors : DescriptionBranch wire copper
Wiring Notes : Representativenumber of outlets and fixturestested
17: GARAGE - DETACHED
Information
Observations
17.1.1 Exterior WallsSLIGHT BOW AT TOP OF WALL STRUCTURE -CABLES/TURNBUCKLES SUPPORTRecommendationRecommend monitoring.
Maintenance Item
17.2.1 RoofROOFING MATERIALS AT/NEAR END OF USEFUL LIFESPANRecommendationContact a qualified roofing professional.
Repair Recommendation
1408 16th Ave NW David Kemper
Homepro Inspections Page 22 of 26
17.3.1 Trim, Soffit, EavesTRIM MATERIALS AT OR NEAREND OF LIFESPANRecommendationContact a qualified siding specialist.
Repair Recommendation
17.8.1 SheathingOLD DRY MOISTURE STAINS PRESENTMonitor
RecommendationContact a qualified roofing professional.
Maintenance Item
17.11.1 Floor/FoundationSURFACE RAISED/SETTLED
Maintenance Item
17.11.2 Floor/FoundationRECOMMEND FURTHER EVALUATION FOR STRUCTURALINTEGRITYRecommendationContact a foundation contractor.
Repair Recommendation
1408 16th Ave NW David Kemper
Homepro Inspections Page 23 of 26
17.12.1 Service DoorTHRESHOLD DAMAGED/MISSINGRecommendationContact a handyman or DIY project
Maintenance Item
17.14.1 Door OpenerRECOMMEND ADJUSTING AUTO REVERSE DOWN PRESSURERecommendationContact a handyman or DIY project
Maintenance Item
17.15.1 Electrical PanelOPENINGS IN THE PANELSHOULD BE COVEREDRecommendationContact a qualified professional.
Repair Recommendation
1408 16th Ave NW David Kemper
Homepro Inspections Page 24 of 26
17.18.1 GFCI'sRECOMMEND GFCISGARAGERecommendationContact a qualified electrical contractor.
Repair Recommendation
1408 16th Ave NW David Kemper
Homepro Inspections Page 25 of 26