  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    1/32

    HiPath 3000/5000

    Version 4.0

    Getting Started

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    2/32

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    3/32

    GetstartedTOC.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 0-1 

    For internal distribution only Contents

    Contents 0

    1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

    2 HiPath 3000 V4.0 Standalone IP System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12.1 Important Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22.2 Step by Step Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

    3 HiPath 3000 V4.0 Networked IP System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13.1 Important Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23.2 Step by Step Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

    4 HiPath 5000 RSM V4.0 Multi-Node IP System  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14.1 Important Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

    4.2 Step by Step Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4

    Index  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z-1

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    4/32

    Contents For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    0-2 HiPath 3000/5000 V4.0, Getting Started

     

    GetstartedTOC.fm

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    5/32

    intro.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 1-1 

    For internal distribution only Introduction

    1 Introduction

    HiPath 3000/5000 V4.0 is a highly scalable communications system designed for both small

    and medium sized companies as well as for extensive Enterprise networks. HiPath 3000/5000V4.0 is available in various configurations and variants – from straightforward standalone sys-tems with a small number of stations through to centrally administrated networks with 64 nodesand up to 2000 workpoint clients. The system architecture avails of the advantages of distrib-uted systems to spread the load placed on individual components and to achieve optimal per-formance.

    HiPath 3000/5000 V4.0 is available in the following four basic variants:

    ● HiPath 3000 V4.0 Standalone IP System:The standalone system is based on Euro-ISDN for connecting analog workpoint clients,

    digital workpoint clients (such as optiPoint 500, optiPoint 600) and IP-based workpoint cli-ents (such as optiPoint 400 and optiClient 130).

    ● HiPath 3000 V4.0 Networked IP System:The networked system is a network of several HiPath 3000 V4.0 (nodes) networked over IP

    ● HiPath 5000 RSM V4.0 Multi-Node IP System:The Multi-Node system consists of several HiPath 3000 V4.0 (nodes) networked over IPwith a central HiPath 5000 RSM server. HiPath 5000 RSM (Real-time Service Manager) isbased on the Windows 2000 server and features open architecture which permits the im-plementation of different scenarios and individual capacity limits. The entire system is cen-trally administrated via the HiPath 5000 RSM server.

    ● HiPath 3000/5000 V4.0 Distributed Architecture:This is a HiPath 5000 RSM V4.0 Multi-Node IP System with a central HiPath 5000 RSMserver and an additional applications server.

    >A general introduction to the HiPath 3000/5000 family of products can be found● in the System Description and● in the Service Manual of the HiPath 3000/5000 V4.0. These documents also contain detailed informationon system installation and startup.

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    6/32

    Introduction For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    1-2 HiPath 3000/5000 V4.0, Getting Started

     

    intro.fm

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    7/32

    IP_standalone.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 2-1 

    For internal distribution only HiPath 3000 V4.0 Standalone IP System

    2 HiPath 3000 V4.0 Standalone IP System

    Overview

    HiPath 3000 V4.0 IP enables mixed mode operation with analog workpoint clients, digital work-point clients (such as optiPoint 500 and optiPoint 600) and IP-based workpoint clients (suchas optiPoint 400 and optiClient 130).

    LAN/IP

    IP phones, e.g.optiPoint 400

    optiClient 130,optiClient Atten-dant

    HiPath 3000incl. HG1500

    HiPath Cordless integrated

    HiPath applicationserver, e.g.HiPath XpressionsHiPath ProCenterSimplyPhone,...

    UP0/E phones, e.g.optiPoint 500/600

    PSTN/ISDN

    Analog phones/faxes

    HiPath Wireless

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    8/32

    HiPath 3000 V4.0 Standalone IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    2-2 HiPath 3000/5000 V4.0, Getting Started

     

    IP_standalone.fm

    Important Information 

    2.1 Important Information

    This document contains brief installation and startup instructions for a HiPath 3000 with aHG1500 module. It is intended for trained service personnel who want a brief overview of the

    chronological sequence of startup activities.

    The following points must be performed or clarified before a HiPath 3000 system is installedand started up. Cross references to the associated documentation provide further details. If youhave these instructions as an electronic document (Help), click the blue links and you will beforwarded to the corresponding documentation.

     Subject Description Detailedinformation

    Safety notes Please read the relevant safety notes on installing, upgrad-ing and starting HiPath 3000.

    HiPath 3000/5000Service Manual

    Delivery docu-ments

    Compare items delivered with the units listed in the deliverydocuments.Were all ordered items delivered?

    -

    Complete-ness/integrity

    Test unit integrity.Are there signs of transport damage?

    -

    Licensing Is all the necessary information (for example the MAC ID ofthe first HiPath HG 1500 and the MAC ID of all other HiPathHG 1500 systems, customer number, contract number andpacking slip number) available for the post Licensing of the

    features, IP workpoint clients, B channels and TAPI licencesordered? Is there Internet access for licensing?

    Requirementsspecifications,Licensing docu-ment,

    HiPath 3000/5000Service Manual

    Licensing serverURL:http://cls.icn.sie-mens.de

    Require-ments specifi-cations

    Are the requirements specifications agreed with the custom-er available and do they contain all the necessary data?Is the data complete or is further information required?

    -

    Numbering

    plan

    Has a numbering plan been developed in line with customer

    requirements?Refer if neces-

    sary to the Re-quirements speci-fications

    Installationsite conditions

    Does the installation site meet all necessary requirements interms of surroundings and power supply?

    HiPath 3000/5000Service Manual

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    9/32

    IP_standalone.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 2-3 

    For internal distribution only HiPath 3000 V4.0 Standalone IP System

    Important Information 

    Customer

    LAN

    Does the customer LAN meet the requirements for Voice

    over IP? Has a network analysis been performed? Are theresults available?

    Requirements

    specifications,

    HiPath 3000/5000Service Manual

    Administration HiPath 3000 is configured by means of the HiPath 3000/ 5000 Manager E service tool. To configure the HG1500module, HiPath 3000 Manager I is required. The softwareshould be available on the technician’s service laptop orshould be installed on the stationary PC at the customer site(in agreement with the customer). V.24 or Ethernet interfac-es are used for connecting to the HiPath 3000 system.

    -

     Subject Description Detailedinformation

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    10/32

    HiPath 3000 V4.0 Standalone IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    2-4 HiPath 3000/5000 V4.0, Getting Started

     

    IP_standalone.fm

    Step by Step Startup 

    2.2 Step by Step Startup

    Perform the steps described below in chronological order to start up a HiPath 3000 IP systemwith a HG1500 module. Each subject has a cross reference to relevant documentation provid-

    ing further details. If you have these instructions as an electronic document (Help), click theblue links and you will be forwarded to the corresponding documentation.

    Status Activity/description Detailedinformation

    1. Installing the hardware

    Mounting/installing the HiPath 3000 HiPath 3000/5000Service Manual

    Mounting and installing the client PCs, application server PC and- if necessary - switches and routers

    Mounting, installing and cabling of workpoint clients on a system-specific basis

    HiPath 3000/5000Service Manual

    Connecting components to the customer LAN HG 1500 Adminis-tration Manual

    Status:HiPath 3000 and the workpoint clients in use are located at theirinstallation sites and are physically connected to the customernetwork.

    -

    2. Installing additional HiPath 3000 modules

    The system must be disconnected from the power source (in thecase of HiPath 35x0 and HiPath 5000 33x0) before new modulesare added.

    HiPath 3000/5000Service Manual

    Check the available ports (master/slave) for each slot (HDLC). HiPath 3000/5000Service Manual

    3. Starting up the HiPath 3000

    Connect the system to the power source. HiPath 3000/5000Service Manual

    Perform country initialization, if necessary. HiPath 3000/5000Service Manual

    Enter the system call number. HiPath 3000/5000Service Manual

    Perform a quick check. HiPath 3000/5000Service Manual

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    11/32

    IP_standalone.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 2-5 

    For internal distribution only HiPath 3000 V4.0 Standalone IP System

    Step by Step Startup 

    Status:HiPath 3000 has been started and is recognizing the workpointclients.

    4. Assigning an IP address (for the HG1500 module and HiPath 3000)

    Note:Before assigning an IP address, use PING to ensure that this ad-dress has not already been assigned.

    -

    System integration in a LAN:Perform initial configuration (assign the IP address of the LAN

    network interface) of all available HG 1500 modules via SLIP ac-cess (serial interface) with HiPath 3000 Manager I.It is also possible to do the initial configuration using ARP over IP.

    HG 1500 Adminis-tration Manual

    For more information refer to the HG1500 CDB via the menuFile | Transfer customer database to PC .

    Assign an IP address and a subnet mask (IP network mask) un-der Settings | Network Interface | Network Interface | LAN

    Restore the CDB via the menuFile | Transfer customer database to LAN card.

    Load the HiPath 3000 CDB using the HiPath 3000/5000 ManagerEFile | Transfer | Communication | System PC

    HiPath 3000/5000Manager E

    Activate the HIP forwarding function via HiPath 3000/5000 Man-ager E and then assign the IP address to the system.Settings | Network | Basic settings | IP Access

    HiPath 3000/5000Manager E

    Save the CDB.File | Save

    HiPath 3000/5000Manager E

    Restore the data to the system.File | Transfer | Communication | PC System

    HiPath 3000/5000Manager E

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    12/32

    HiPath 3000 V4.0 Standalone IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    2-6 HiPath 3000/5000 V4.0, Getting Started

     

    IP_standalone.fm

    Step by Step Startup 

    5. Configuring the IP clients

    Load the HiPath 3000 CDB using the HiPath 3000/5000 ManagerE.File | Transfer | Communication | System PC

    HiPath 3000/5000Manager E

    Configure the IP stations and lines via System Status | System-wide | Cards | Software Expansion | Module Configuration |HXGM Configuration.

    HiPath 3000/5000Manager E

    Note:“SystemClients” for optiPoint IP and optiClient

    “So-Stations” for H.323 clients and VCAPI stations

    Save the CDB.File | Save

    HiPath 3000/5000Manager E

    Restore the data to the system.File | Transfer | Communication | PC System

    HiPath 3000/5000Manager E

    Status:The HiPath 3000 IP stations can now be administrated.

    -

    6. Further configuration

    The following important parameters must then beconfigured, for example via HiPath 3000/5000 Manager E:

    Stations/Workpoint ClientsSettings | Set up Station | Select Stations | Param | WorkpointClient

    HiPath 3000/5000Manager E

    TrunksSettings | Lines/networking | Trunks

    HiPath 3000/5000Manager E

    RoutesSettings | Lines/Networking | Routes

    HiPath 3000/5000Manager E

    Class of Services

    Settings | Least Cost Routing | Class of ServicesHiPath 3000/5000

    Manager E

    Call numbersSettings | Set up Station

    HiPath 3000/5000Manager E

    LCRSettings | Least Cost Routing

    HiPath 3000/5000Manager E

    Customer-specific system programming HiPath 3000/5000Service Manual

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    13/32

    IP_Network.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 3-1 

    For internal distribution only HiPath 3000 V4.0 Networked IP System

    3 HiPath 3000 V4.0 Networked IP System

    Overview

    HiPath 3000 V4.0 Networked IP enables mixed mode operation with analog workpoint clients,digital workpoint clients (such as optiPoint 500 and optiPoint 600) and IP-based workpoint cli-ents (such as optiPoint 400 and optiClient 130). It also makes it possible to network severalnodes over IP.

    LAN/IP

    IP phones, e.g.optiPoint 400

    optiClient 130,optiClient Atten-

    dant

    HiPath 3000incl. HG1500

    HiPath Cordless integrated

    HiPath applicationserver, e.g.HiPath XpressionsHiPath ProCenterSimplyPhone,...

    UP0/E phones, e.g.optiPoint 500/600

    PSTN/ISDN

    Analog phones/faxes

    HiPath Wireless

    PSTN/ISDN

    UP0/E phones, e.g.optiPoint 500/600

    HiPath 3000incl. HG1500

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    14/32

    HiPath 3000 V4.0 Networked IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    3-2 HiPath 3000/5000 V4.0, Getting Started

     

    IP_Network.fm

    Important Information 

    3.1 Important Information

    This document contains brief installation and startup instructions for a HiPath 3000 with aHG1500 module. It is intended for trained service personnel who want a brief overview of the

    chronological sequence of startup activities.

    The following points must be performed or clarified before a HiPath 3000 system is installedand started up. Cross references to the associated documentation provide further details. If youhave these instructions as an electronic document (Help), click the blue links and you will beforwarded to the corresponding documentation.

     Subject Description Detailedinformation

    Safety notes Please read the relevant safety notes on installing, upgradingand starting HiPath 3000 systems.

    HiPath 3000/5000Service Manual

    Deliverydocuments

    Compare items delivered with the units listed in the deliverydocuments. Were all ordered items delivered?

    -

    Complete-ness/integri-ty

    Test unit integrity. Are there signs of transport damage? -

    Licensing Is all the necessary information (for example the MAC ID of thefirst HiPath HG 1500 in the HiPath 3000 with the lowest nodeID and the MAC ID of all other HiPath HG 1500 systems, cus-tomer number, contract number and packing slip number)

    available for the post Licensing of the features, IP workpoint cli-ents, B channels and TAPI licences ordered? Is there Internetaccess for licensing?

    Requirementsspecifications,Licensing docu-ment,

    HiPath 3000/5000Service Manual

    Licensing serverURL:http://cls.icn.sie-mens.de

    Require-ments spec-ifications

    Are the requirements specifications agreed with the customeravailable and do they contain all the necessary data? Is thedata complete or is further information required?

    -

    Numbering

    plan

    Has a numbering plan been developed in line with customer

    requirements?Refer if necessary

    to the Require-ments specifica-tions

    Installationsite condi-tions

    Does the installation site meet all necessary requirements interms of surroundings and power supply?

    HiPath 3000/5000Service Manual

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    15/32

    IP_Network.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 3-3 

    For internal distribution only HiPath 3000 V4.0 Networked IP System

    Important Information 

    Customer

    LAN

    Does the customer LAN meet the requirements for Voice over

    IP? Has a network analysis been performed? Are the resultsavailable?

    Requirements

    specifications,

    HiPath 3000/5000Service Manual

    Administra-tion

    HiPath 3000 is configured by means of theHiPath 3000 5000 Manager E service tool. To configure theHG1500 module, HiPath 3000 Manager I is required. The soft-ware should be available on the technician’s service laptop orshould be installed on the stationary PC at the customer site(in agreement with the customer). V.24 or Ethernet interfacesare used for connecting to the HiPath 3000 system.

    -

     Subject Description Detailedinformation

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    16/32

    HiPath 3000 V4.0 Networked IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    3-4 HiPath 3000/5000 V4.0, Getting Started

     

    IP_Network.fm

    Step by Step Startup 

    3.2 Step by Step Startup

    Perform the steps described below in chronological order to start up a HiPath 3000 systemwith a HG1500 module. Each subject has a cross reference to relevant documentation provid-

    ing further details. If you have these instructions as an electronic document (Help), click theblue links and you will be forwarded to the corresponding documentation.

    Status Activity/description Detailedinformation

    1. Installing the hardware

    Mounting/installing the HiPath 3000 HiPath 3000/5000Service Manual

    Mounting and installing the client PCs, application server PC and- if necessary - switches and routers

    Mounting, installing and cabling of workpoint clients on a system-specific basis

    HiPath 3000/5000Service Manual

    Connecting components to the customer LAN HG 1500 Adminis-tration Manual

    Status:HiPath 3000 and the workpoint clients in use are located at theirinstallation sites and are physically connected to the customernetwork.

    -

    2. Installing additional HiPath 3000 modules

    The system must be disconnected from the power source (in thecase of HiPath 35x0 and HiPath 5000 33x0) before new modulesare added.

    HiPath 3000/5000Service Manual

    Check the available ports (master/slave) for each slot (HDLC). HiPath 3000/5000Service Manual

    3. Starting up the HiPath 3000

    Connect the system to the power source. HiPath 3000/5000Service Manual

    Perform country initialization, if necessary. HiPath 3000/5000Service Manual

    Enter the system call number. HiPath 3000/5000Service Manual

    Perform a quick check. HiPath 3000/5000Service Manual

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    17/32

    IP_Network.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 3-5 

    For internal distribution only HiPath 3000 V4.0 Networked IP System

    Step by Step Startup 

    Status:HiPath 3000 has been started and is recognizing the workpoint cli-ents.

    4. Assigning an IP address (for the HG1500 module and HiPath 3000)

    Note:Before assigning an IP address, use PING to ensure that this ad-dress has not already been assigned.

    -

    System integration in a LAN:Perform initial configuration (assign the IP address of the LAN

    network interface) of all available HG 1500 modules via SLIP ac-cess (serial interface) with HiPath 3000 Manager I.It is also possible to do the initial configuration using ARP over IP.

    HG 1500 Adminis-tration Manual

    For more information refer to the HG1500 CDB via the menuFile | Transfer customer database to PC .

    Assign an IP address and a subnet mask (IP network mask) underSettings | Network Interfaces | Network Interfaces | LAN

    Restore the CDB via the menuFile | Transfer customer database to LAN card.

    Load the HiPath 3000 CDB using the HiPath 3000/5000 ManagerEFile | Transfer | Communication | System PC

    HiPath 3000/5000Manager E

    Activate the HIP forwarding function via HiPath 3000/5000 Man-ager E and then assign the IP address to the system.Settings | Network | Basic settings | IP Access

    HiPath 3000/5000Manager E

    Save the CDB.File | Save

    HiPath 3000/5000Manager E

    Restore the data to the system.File | Transfer | Communication | PC System

    HiPath 3000/5000Manager E

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    18/32

    HiPath 3000 V4.0 Networked IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    3-6 HiPath 3000/5000 V4.0, Getting Started

     

    IP_Network.fm

    Step by Step Startup 

    5. Configuring the IP clients

    Load the HiPath 3000 CDB using the HiPath 3000/5000 ManagerE.File | Transfer | Communication | System PC

    HiPath 3000/5000Manager E

    Configure the IP stations and lines via System Status | System-wide | Cards | Software Expansion | Module Configuration |HXGM Configuration.

    HiPath 3000/5000Manager E

    Note:“SystemClients” for optiPoint IP and optiClient

    “"So-Stations” for H.323 clients and VCAPI stations

    Save the CDB.File | Save

    HiPath 3000/5000Manager E

    Restore the data to the system.File | Transfer | Communication | PC System

    HiPath 3000/5000Manager E

    Status:The HiPath 3000 IP stations and lines can now be administrated.

    -

    6. Further configuration

    The following important parameters must then beconfigured, for example via HiPath 3000/5000 Manager E:

    Stations/Workpoint ClientsSettings | Set up Station | Select Stations | Param | WorkpointClient

    HiPath 3000/5000Manager E

    TrunksSettings | Lines/Networking | Trunks

    HiPath 3000/5000Manager E

    RoutesSettings | Lines/Networking | Routes

    HiPath 3000/5000Manager E

    Class of Services

    Settings | Least Cost Routing | Class of ServicesHiPath 3000/5000

    Manager E

    Call numbersSettings | Set up Station

    HiPath 3000/5000Manager E

    LCRSettings | Least Cost Routing

    HiPath 3000/5000Manager E

    Customer-specific system programming HiPath 3000/5000Service Manual

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    19/32

    verbund.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 4-1 

    For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System

    4 HiPath 5000 RSM V4.0 Multi-Node IP System

    Overview

    HiPath 5000 RSM V4.0 Multi-Node System is a network of several IP-networked nodes (HiPath3000). It is centrally administrated via the HiPath 5000 RSM server, which also supports othercentral applications.

    LAN/IP

    HiPath 5000 RSMincl. Feature Server, HiPathManager E/C/I and applica-tions (with HiPath Xpres-sions, HiPath ProCenter,

    HiPath SimplyPhone, etc.)

    IP phones, e.g.optiPoint 400

    optiClient 130,optiClient Attendant

    HiPath 3000incl. HG1500

    HiPath Cordless integrated

    HiPath applications server,for example with HiPathXpressions, HiPath Pro-Center, HiPath Simply-Phone, etc. (only for Hi-Path 3000/5000 distributed

    architecture)

    UP0/E phones, e.g.

    optiPoint 500/600

    PSTN/ISDN

    Analog phones/faxes

    HiPath Wireless

    PSTN/ISDN

    UP0/E phones, e.g.optiPoint 500/600

    HiPath 3000incl. HG1500

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    20/32

    HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    4-2 HiPath 3000/5000 V4.0, Getting Started

     

    verbund.fm

    Important Information 

    4.1 Important Information

    This document contains brief installation and startup instructions for a HiPath 3000 networkwith a HiPath 5000 RSM server PC. It is intended for trained service personnel who want a

    brief overview of the chronological sequence of startup and configuration activities.

    The following points must be performed or clarified before a HiPath 3000/5000 network is in-stalled and started up. Cross references to the associated documentation provide further de-tails. If you have these instructions as an electronic document (Help), click the blue links andyou will be forwarded to the corresponding documentation.

     Subject Description Detailedinformation

    Safety notes Please read the relevant safety notes on installing, upgradingand startingHiPath 3000/5000 systems.

    HiPath 3000/5000Service Manual

    Deliverydocuments

    Compare items delivered with the units listed in the deliverydocuments. Were all ordered items delivered?

    -HiPath 3000/5000Service Manual

    Complete-ness/integri-ty

    Test unit integrity. Are there signs of transport damage? -

    Licensing Is all the necessary information (such as the MAC ID of thefirst HiPath HG 1500 and the MAC ID of the HiPath 3000 CB(Control Board) with the lowest node ID as well as the MACID of all other HiPath HG 1500 systems, customer number,contract number and packing slip number) available for thepost licensing of the features, IP workpoint clients, B chan-nels, TAPI licences ordered and the feature server? Is thereInternet access for licensing?Note:The evaluation time for the Feature Server expires after a pe-riod of five days. The relevant license must be entered withinthis time.

    Requirementsspecifications,Licensing docu-ment,

    HiPath 3000/5000Service Manual

    Licensing serverURL:http://cls.icn.sie-mens.de

    Require-ments speci-fications

    Are the requirements specifications agreed with the custom-er available and do they contain all the necessary data? Isthe data complete or is further information required?

    -

    Numberingplan

    Has a numbering plan been developed in line with customerrequirements?

    Refer if necessaryto the require-ments specifica-tions

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    21/32

    verbund.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 4-3 

    For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System

    Important Information 

    Installation

    site condi-tions

    Does the installation site meet all necessary requirements in

    terms of surroundings and power supply?

    HiPath 3000/5000

    Service Manual

    CustomerLAN

    Does the customer LAN meet the requirements for Voiceover IP? Has a network analysis been performed? Are the re-sults available?

    Requirementsspecifications,

    HiPath 3000/5000Service Manual

    Administra-tion

    The HiPath 3000 5000 Manager E and HiPath5000 3000 Manager I service tools are required for setting upand configuring the entire system. The software should beavailable on the technician’s service laptop or should be in-stalled on the HiPath 5000 RSM Feature Server for centraladministration. You can install both of these programs fromCD 1 via the master setup. V.24 or Ethernet interfaces areused for connecting to the HiPath 3000/5000 system.

    -

     Subject Description Detailedinformation

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    22/32

    HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    4-4 HiPath 3000/5000 V4.0, Getting Started

     

    verbund.fm

    Step by Step Startup 

    4.2 Step by Step Startup

    Perform the steps described below in chronological order to start up a HiPath 3000 withAllServe V4.0. Each subject has a cross reference to relevant documentation providing further

    details. If you have these instructions as an electronic document (Help), click the blue links andyou will be forwarded to the corresponding documentation.

    Status Activity/description Detailedinformation

    1. Installing the hardware

    Mounting/installing the HiPath 3000 (nodes) HiPath 3000/5000Service Manual

    Mounting and installing the HiPath 5000 Feature Server, clientPCs and - if necessary - switches and routers

    HiPath 3000/5000Service Manual

    Mounting, installing and cabling of workpoint clients on a system-specific basis

    HiPath 3000/5000Service Manual

    Connecting components to the customer LAN HG 1500 Adminis-tration Manual

    Status:The HiPath 3000 nodes, server and workpoint clients are locatedat their installation sites and are physically connected to the cus-tomer network.

    -

    2. Installing additional HiPath 3000 modules

    The system must be disconnected from the power source (in thecase of HiPath 35x0 and HiPath 5000 33x0) before new modulesare added.

    HiPath 3000/5000Service Manual

    Check the available ports (master/slave) for each slot (HDLC). HiPath 3000/5000Service Manual

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    23/32

    verbund.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 4-5 

    For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System

    Step by Step Startup 

    3. Starting up HiPath 3000

    Connect the system to the power source. HiPath 3000/5000Service Manual

    Perform country initialization, if necessary. HiPath 3000/5000Service Manual

    Enter the system call number. HiPath 3000/5000Service Manual

    Perform a quick check. HiPath 3000/5000Service Manual

    Status:The HiPath 3000 have been started and are recognizing the work-point clients.

    -

    4. HiPath 5000 RSM Feature Server installation

    Install all marketed components using master setup. HiPath 3000/5000Service Manual

    Note:During installation, perform only basic configuration for the re-spective components when prompted. Once installation is com-

    plete, the user, TAPI lines, clients and B channels should also beconfigured.

    Install the HiPath3000/5000 Manager E and the HiPath 3000Manager I via the master setup.

    HiPath 3000/5000Service Manual

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    24/32

    HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    4-6 HiPath 3000/5000 V4.0, Getting Started

     

    verbund.fm

    Step by Step Startup 

    5. Assigning an IP address (for the HG1500 module and HiPath 3000 systems)

    Note:Before assigning an IP address, use PING to ensure that this ad-dress has not already been assigned.

    -

    System integration in a LAN:Perform initial configuration (assign the IP address of the LANnetwork interface) of all available HG 1500 modules via SLIP ac-cess (serial interface) with HiPath 3000 Manager I.It is also possible to do the initial configuration using ARP over IP.

    HG 1500 Adminis-tration Manual

    For more information refer to the HG1500 CDB via the menuFile | Transfer customer database to PC .

    Assign an IP address and a subnet mask (IP network mask) un-der Settings | Network Interface | Network Interface | LAN

    Restore the CDB via the menuFile | Transfer customer database to LAN card.

    Load every available HiPath 3000 node CDB one after the otherusing HiPath 3000/5000 Manager E.File | Transfer | Communication | System PC

    HiPath 3000/5000Manager E

    Activate the HIP forwarding function via HiPath 3000/5000 Man-ager E and then assign the IP address to the system.Settings | Network | Basic Settings | IP Access

    HiPath 3000/5000Manager E

    Save the CDB.File | Save

    HiPath 3000/5000Manager E

    Restore the data to the system.File | Transfer | Communication | PC System

    HiPath 3000/5000Manager E

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    25/32

    verbund.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 4-7 

    For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System

    Step by Step Startup 

    6. Configuring Feature Server functionality (preparing HiPath 3000 nodes for the net-work)

    Load every available HiPath 3000 node CDB one after the otherusing HiPath 3000/5000 Manager E.File | Transfer | Communication | System PC

    HiPath 3000/5000Manager E

    Activate the HiPath 5000 RSM functionality(enter the unique node ID and server IP address for HiPath 3000).Settings | Network | HiPath 5000 RSM Parameters

    HiPath 3000/5000Manager E

    Configure the IP stations and lines via

    System Status | System-wide | Cards | Software Expansion |Module Configuration | HXGM Configuration:“SystemClients” for optiPoint IP and optiClient“So-Stations” for H.323 clients and VCAPI stations

    HiPath 3000/5000

    Manager E

    Note:If you are setting up IP lines, use Settings | Network | HiPath5000 Parameters to allow access to the HG1500 by the HiPath5000 server.

    HiPath 3000/5000Manager E

    Save the CDB.File | Save

    HiPath 3000/5000Manager E

    Restore the data to the system.File | Transfer | Communication | PC System

    HiPath 3000/5000Manager E

    Status:All HiPath 3000 systems can now be administered via the networkand the IP stations and trunks can be set up.

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    26/32

    HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    4-8 HiPath 3000/5000 V4.0, Getting Started

     

    verbund.fm

    Step by Step Startup 

    7. Merging of HiPath 3000 (nodes)

    Load the default data from the HiPath 5000 RSM Server.

    Then select the appropriate server under File | HiPath 5000 RSM| Transfer | HiPath 5000 RSM Server via the Search button.Then click Server - Manager.

    Add new nodes (read out the CDB data of the respective nodes;repeat this process for each of the available nodes beginning withthe node that has the shortest node ID).

    File | HiPath 5000 RSM | New | HiPath 3000

    HiPath 3000/5000Manager E

    Transfer the central database CDB by selectingFile | HiPath 5000 RSM | Transfer | HiPath 5000 RSM Server |Add Node

    HiPath 3000/5000Manager E

    If the HG1500 is not recognized by the Feature Server, reset allmodules selected as gateways via HiPath 3000 Manager I (or al-ternatively reset the system).

    HG 1500 Adminis-tration Manual

    Note:To add further nodes, perform the step described above.

    -

    Status:All nodes can now be centrally administered via the HiPath 3000/ 5000 Manager E (Load via Server button).

    HiPath 3000/5000Manager E

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    27/32

    verbund.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started 4-9 

    For internal distribution only HiPath 5000 RSM V4.0 Multi-Node IP System

    Step by Step Startup 

    8. Licensing

    To license the Feature Server, transfer the LIC file generated onthe licensing server (http://cls.icn.siemens.de) to the CDB directo-ry.Check the path name to the LIC file in the vsrv.ini.

    Licensing can be performed either immediately or within five daysof startup. The MAC ID of the CB (control board) of theHiPath 3000 system with the lowest node ID is required for li-censing.

    HiPath 3000/5000Service Manual

    The MAC ID of the first HG1500 in the HiPath 3000 with the low-est node ID is required for licensing TAPI lines (TAPI 170).Enter the license key as explained in the TAPI 170 online help.

    The HG1500 MAD ID is required for licensing HG 1500 IP clients(such as optiPoints) and B channels. Release the B channels andIP clients with the HiPath 3000 Manager I under Service Li-censed B Channels and Licensed Clients and transfer the CDB.Now read out the CDB again, increase the number of B channelsin use and copy back the CDB.

    IP clients (optiClients) are licensed during installation.

    HiPath TAPI 120 is licensed during installation.

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    28/32

    HiPath 5000 RSM V4.0 Multi-Node IP System For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    4-10 HiPath 3000/5000 V4.0, Getting Started

     

    verbund.fm

    Step by Step Startup 

    9. Further configuration

    The following important parameters must then beconfigured, for example via HiPath 3000 5000 Manager E:

    Stations/Workpoint ClientsSettings | Set up Station | Select Stations | Param | WorkpointClient

    HiPath 3000/5000Manager E

    TrunksSettings | Lines/networking | Trunks

    HiPath 3000/5000Manager E

    RoutesSettings | Lines/Networking | Routes HiPath 3000/5000Manager E

    Class of ServicesSettings | Least Cost Routing | Class of Services

    HiPath 3000/5000Manager E

    Call numbersSettings | Set up Station

    HiPath 3000/5000Manager E

    LCRSettings | Least Cost Routing

    HiPath 3000/5000Manager E

    customer-specific system programming HiPath 3000/5000Service Manual

    Status Activity/description Detailedinformation

    =checked

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    29/32

    GetstartedSIX.fm

    A31003-H3540-C100-3-76D1, 03-2004

    HiPath 3000/5000 V4.0, Getting Started Z-1 

    For internal distribution only Index

    Index Z

    HHiPath 3000 Networked IP System

    Assigning IP addresses 3-5Configuring IP clients 3-6Delivery documents 3-2Installing additional modules 3-4Installing the hardware 3-4Licensing 3-2Requirements specifications 3-2Safety notes 3-2

    Startup 3-4HiPath 3000 Standalone IP System

    Assigning IP addresses 2-5Configuring IP functionality 2-6Delivery documents 2-2Installation 2-4Installing the hardware 2-4Licensing 2-2Numbering plan 2-2Requirements specifications 2-2

    Safety notes 2-2Startup 2-4HiPath 5000 RSM Multi-Node System

    Installing additional HiPath 3000 modules4-4

    Installing the hardware 4-4HiPath 5000 RSM Multinode System

    Assigning IP addresses 4-6Configuring the Feature Server 4-7Delivery documents 4-2Installation 4-5

    Licensing 4-2, 4-9Merging nodes 4-8Numbering plan 4-2Requirements specifications 4-2Safety notes 4-2Startup 4-5

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    30/32

    Index For internal distribution only

     A31003-H3540-C100-3-76D1, 03-2004

    Z-2 HiPath 3000/5000 V4.0, Getting Started

     

    GetstartedSIX.fm

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    31/32

  • 8/20/2019 HiPath 3000 5000 V4.0 Getting Started

    32/32

     Siemens AG 2004 • Information and Communication

    The information provided in this document contains merely gener-

    al descriptions or characteristics of performance which in case of

    actual use do not always apply as described or which may change

    as a result of further development of the products.

    An obligation to provide the respective characteristics shall only ex-

    ist if expressly agreed in the terms of contract.

    www.siemens.com/hipath