higher order statistics in magnetoacoustic ndt nicolae cretu*, gelu m nita**, attila boer*, mihail...
TRANSCRIPT
![Page 1: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/1.jpg)
Higher order statistics in
magnetoacoustic NDT
Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop**Physics Department, Transilvania University, Eroilor nr. 29, Brasov, 500036, Romania**New Jersey Institute of Technology, Center for Solar Terrestrial ResearchCorresponding author: [email protected]
Transilvania University of Braşov - ROMANIA
CNDT 2009 Prague
![Page 2: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/2.jpg)
Introduction
The present work contains a study for the application of some methods from statistics in nondestructive evaluation and nondestructuve testing
The application of higher order statistics assumes that the most evaluation methods involve the computer and his great facility to compute large bloks of experimental data
Higher order statistics means statistics which implies higher order central moments and cumulants
By definition for a discrete set of data the central moment of order m is:
The work analyses especially the aplication of the statistical magnitude named Kurtosis to the magnetoacoustic phenomenon.
mn
i
mi xxxx
n)()(
1
1
![Page 3: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/3.jpg)
What´s the Kurtosis?
By definition
4)(4 xx
2)( xx
22 )(
4
K
Central moment of order 4
Standard deviation
•Is also used Excess of Kurtosis (EK) given by: EK=K-3
2 the Variance
![Page 4: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/4.jpg)
Kurtosis of a signal with uniform distribution in time
K=1.8 EK=-1.2
![Page 5: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/5.jpg)
Harmonic signal
K=1.5 EK=-
1.5
![Page 6: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/6.jpg)
Gaussian signal K=3, EK=0
![Page 7: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/7.jpg)
Spectral Kurtosis (SK)
Operates in the frequency domain Is a Kurtosis of the amplitudes of
the spectral components or of the power spectral components
Can be used to detect transient signals which appear during the evolution of the phenomenon Dynamic SK
![Page 8: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/8.jpg)
Dynamic SK
The data aquisition has a special formalism:-N spectra in time, each spectrum has a number m=1024 samples
at the aquisition frequency f.-the m=1024 samples in time are used by FFT to produce a
spectrum of m=1024 frequencies between the limits –f/2, +f/2-the Power Spectral Density (PSD) will contain m/2=512 components
in the frequency domain 0-f/2-for a number M=300…500 of subspectra we compute S1 and S2:
-for M subspectra we obtain an SK estimator given by:
M
m
kM
mmkPSmkPS
1
channelfrequency ;
1
2,2 ;,1
ondistributiGaussianwithsignalaforSK
S
SM
M
MSK
1
,11 1
2
![Page 9: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/9.jpg)
SK for detection of the transient signals
SK detection of three transient stationary signals
![Page 10: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/10.jpg)
Magnetoacoustic emission The magnetoacoustic effect is specific for elastic magnetic materials , precisely for
ferromagnetic materials, and refeers to the generation of elastic waves in such materials being magnetized in an alternating magnetic field. This effect is an indubitable proof of the existence of the magnetic domains and magnetic domain walls, which explain the magnetization processes in ferromagnets.
It is knew that during the magnetization process , following the magnetization curve of the ferromagnetic materials with the increasing of the external field, first occurs the growing of the magnetic domains, reversible rotation of the magnetization and at high levels of the field irreversible rotation of the magnetization.
At high magnetic fields, only irreversible rotation of the magnetization exists and in this case all domains in an ferromagnet must be oriented parallel with the external magnetic field. But, the existence of the anisotropy or of structural imperfections like defects, gives rise to destroy the local magnetic order and fix the domains in other orientation comparing with the orientation of the external field. So, by applying magnetic fields higher than the magnetic field corresponding to the saturation level, abrupt and discontinuous displacement of magnetic domain walls pinned by inclusions,voids, dislocations, grain boundaries etc, appear.
There are two important phenomena which appear : -Barkhausen noise (BN)-detected in the form of voltage pulses which are
induced in a coil placed near the surface of the material. -Magnetoacoustic Emission (MAE)- detected regularly by piezoelectric
transducers placed on the surface of the sample.
![Page 11: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/11.jpg)
Magnetoacoustic signal
acts like a nongaussian transient signal when the wall between the magnetic domains are pinned around the crystall imperfections or defects
![Page 12: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/12.jpg)
Experimental setup
![Page 13: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/13.jpg)
Sample placement
![Page 14: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/14.jpg)
TDK and SK for a carbon steel sample
![Page 15: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/15.jpg)
TDK and SK for Annealed Carbon Steel
![Page 16: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/16.jpg)
TDK and SK for Ni
![Page 17: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/17.jpg)
TDK and SK for a sample of Ni with artificial created defect
![Page 18: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/18.jpg)
Noise during the mesurements
![Page 19: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/19.jpg)
Conclusions
Estimation of some magnitudes from statistics can give information about the nature of the physical process in materials.
The estimation of dynamic K or SK can be used as an active method of control in NDT
For estimation of dynamic K or SK during the time, is better to use new generation of FPGA aquisition boards.
![Page 20: Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor](https://reader036.vdocuments.site/reader036/viewer/2022062515/56649d205503460f949f53ab/html5/thumbnails/20.jpg)
Thank you for attention!