high voltage training breaker - alfamarine.com

5
HIGH VOLTAGE TRAINING BREAKER TRANSAS ERS 5000 TECHSIM

Upload: others

Post on 03-Apr-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

HigH voltage training breaker

Transas Ers 5000 TEchsim

Transas is a world leader in the manufacture of Engine room simulators used for marine engineering and electrical training. Due to an increase in the number of high voltage ships, the training programme for marine Electrical Engineers has made high voltage training mandatory. a practical element of training has been introduced requiring safety training using real equipment. This does not necessarily have to be live equipment.

To meet this new training requirement, Transas has developed a real hardware high voltage generator breaker cabinet in conjunction with power technology specialist aBB.

equipment suppliedThe breaker is compatible with the existing Transas Techsim simulators with high / medium voltage systems.

high voltage distribution systems can be used in several ship types: ■ DE cruise ship ■ steam Turbine LnG carrier ■ DE LnG Tanker.

Connection to existing simulator The breakers are supplied by the following manufacturers: aBB, hyundai, siemens and mitsubishi. The breakers are fitted with ‘earthing’ arrangements and safety interlocks. Transas offers interconnection between the Techsim simulator and any of the above high voltage breakers.

training objeCtives ■ realistic hands-on training in high voltage switchboard operations

■ Understanding safety as a personal responsibility ■ Electricity and work planning ■ identification of hazards ■ Emergency procedures and contacts / location of emergency gear

■ Knowledge of circuits / power feeds / emergency shutdown and isolation devices

■ Familiarisation with company protocols ■ isolation of breakers in ships’ electrical systems ■ Use of high voltage test equipment ■ Use of high voltage Personal Protective Equipment (PPE)

■ Definition and identification of circuit condition / energised work conditions

■ Practical assessment of personnel and assignment of work / qualification of a worker.

Designed to meet the training requirements set out in section a-iii / 1, a-iii / 2, a-iii / 6 & B-iii / 2 of the sTcW code 2010 (manila amendments).

Existing msB Touch screens

real aBB Breaker

2 3

hiG

h V

OLTa

GE T

rain

inG

BrEa

KEr

Tran

sas

Ers

5000

TEc

hsi

mh

iGh VOLTaGE Train

inG BrEaKEr

Transas Ers 5000 TEch

sim

simulator interfaceThe lower part of the breaker comprises a real breaker operated by the simulator electrical system mathematical model. The upper panel contains the instruments and controls for a typical high voltage generator. The controls and instruments are connected to the simulator model via a digital analogue interface.

To simulate LcD type Power management system controllers, a precisely developed small touch screen display simulates the controller functionality.

The simulator is connected to the breaker using a Wago cOTs automation interface which may also be used for automation training.

test equipmentFor safety reasons high voltages are not used within the training breaker. The presence of high voltages is simulated using low powered radio signals. an adjusted high voltage probe signals the presence of voltage on the bus bars using a specially adapted test probe.

personal protective equipment (ppe)high voltage PPE is supplied as a part of the training breakers equipment.

The bus ties and generator breakers are installed in the main switchboard and are normally ‘front loading’ Vacuum circuit Breakers. The electrical systems are of common design and operate at the following voltages:

■ Up to 6600 V ■ 3 phase ■ 60 hz ■ Generators 3350 to 4000 kW

a complete safe removal and replacement procedure may be conducted for training and assessment. This includes both the mechanical and electrical isolation of the generator system prior to the start of work. all tools, test equipment and personal protective equipment required to carry out the operation are supplied with the breaker. This includes a breaker cart.

transas/abb training breaker

cut away side Panels

with internal lighting for

demonstrations

simulated Generator instrumentation

Breaker automation and Protection LcD Touch screen

Full set of mechanical and Electrical Breaker interlocks

4 5

hiG

h V

OLTa

GE T

rain

inG

BrEa

KEr

Tran

sas

Ers

5000

TEc

hsi

mh

iGh VOLTaGE Train

inG BrEaKEr

Transas Ers 5000 TEch

sim

training proCess training appliCationsbreaker

■ Breaker construction ■ ‘Earthing’ arrengements ■ Breaker safety interlocks ■ isolation testing ■ Breaker removal ■ insulation Testing ■ Breaker replacement ■ setting to work

simulator ■ marine high voltage system instruction ■ Electrical isolation planning ■ Prime mover (generator) mechanical isolation ■ Power management system

Large touch screen mimic for instruction and demonstration

real aBB Breaker

student operator station

instructor station

Large touch screen mimic of mcD

6 7

hiG

h V

OLTa

GE T

rain

inG

BrEa

KEr

Tran

sas

Ers

5000

TEc

hsi

mh

iGh VOLTaGE Train

inG BrEaKEr

Transas Ers 5000 TEch

sim

copyright © 2016 Transas marine Limited. all rights reservedref. no. 90008002

ameriCasTransas americas inc. . . . . . . . . . . . . . . . . . . . . +1425 486 2100 [email protected] Latin america . . . . . . . . . . . . . . . . . . . +54 11 4790 8569 [email protected] Brasil . . . . . . . . . . . . . . . . . . . . . . . . +55 21 2172 5216 [email protected]

asiaTransas marine Limited india . . . . . . . . . . . . . . . . +91 22 2876 3900 [email protected] marine Pacific Pte Ltd. (singapore) . . . . . . . . +65 627 10 200 [email protected] china. . . . . . . . . . . . . . . . . . . . . . . . . +86 21 3329 6750 [email protected]

europeTransas marine Gmbh (Germany) . . . . . . . . . . . . . . +49 40 890 6660 [email protected] scandinavia (sweden). . . . . . . . . . . . . . . . +46 31 769 56 00 [email protected] Denmark. . . . . . . . . . . . . . . . . . . . . . . + 45 3253 8000 [email protected] marine (UK) Ltd.. . . . . . . . . . . . . . . . . . . +44 2392 674 000 [email protected] Benelux (the netherlands) . . . . . . . . . . . . . +31 10 4285599 [email protected] hellas Ltd. (Greece). . . . . . . . . . . . . . . . . +30 210 899 5164 [email protected] Black sea (Turkey) . . . . . . . . . . . . . . . . . +90 216 337 0852 [email protected] Ukraine Ltd. . . . . . . . . . . . . . . . . . . . . . +380 512 507116 [email protected] marine Poland. . . . . . . . . . . . . . . . . . . . +48 58 774 7283 [email protected] Baltic sia (Latvia) . . . . . . . . . . . . . . . . . . +371 6 716 2100 [email protected]

middle east and afriCaTransas middle East Dmc Est.. . . . . . . . . . . . . . . . +97 14 357 3625 [email protected]

mediterraneanTransas mediterranean sas (France) . . . . . . . . . . . . +33 4 89 86 4100 [email protected] mediterranean sas – italian branch. . . . . . . . +39 010 3200 576 [email protected]

russia and CisTransas navigator (russia) . . . . . . . . . . . . . . . . . +7 812 325 31 31 [email protected]

general [email protected]

otHer CountriesFind your local distributor at www.transas.com/distributors