F1 HIGH PRESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron construction filters, provide reliability in demanding industrial applications. Inline, manifold-mount, reverse-flow, bi-directional-flow configurations provide flexibility to accommodate any application. Duplex filters allow for uninterrupted operation during element change-out.

Upload: haphuc

Post on 06-Feb-2018

229 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F1

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

High Pressure Filters3000-6000 psiRobust carbon steel/ductile iron construction filters, provide reliability in demanding industrial applications. Inline, manifold-mount, reverse-flow, bi-directional-flow configurations provide flexibility to accommodate any application. Duplex filters allow for uninterrupted operation during element change-out.

Page 2: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F2

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Gearboxes

Industrial

Pulp & Paper

Offshore

Railways

CommercialMunicipal

Shipbuilding

PowerGeneration

Steel / HeavyIndustry

Features• Non-welded housing design reduces stress concentrations and

prevents fatigue failure.• Choice of NPT, BSPP, SAE straight thread O-ring boss, and SAE

4-bolt flange porting (sizes 60 - 1320) to allow easy installation with maximum flexibility.

• O-ring seals are used to provide positive, reliable sealing. Choice of O-ring materials (nitrile rubber, fluorocarbon elastomer, and ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.

• Screw-in bowl or lid (on 2-pc. bowls) mounted below the filter head requires minimal clearance to remove the element for replacement and contaminated fluid cannot be washed downstream when element is serviced.

• HYDAC Differential Pressure Indicators have no external dynamic seal. This results in a high system reliability due to magnetic actuation, thus eliminating a potential leak point.

• A poppet-type bypass valve located in the filter head provides positive sealing during normal operation and fast opening during cold starts and flow surges. (Optional non-bypass available)

• For special finishes and coatings – consult HYDAC for minimum quantities, availability and pricing.

• Fatigue pressure ratings equal maximum allowable working pressure rating.

DF SeriesInline Filters6090 psi • up to 200 gpm

A

B

Technical SpecificationsMounting Method 4 mounting holesPort Connection 30 60/110 160/240/280

330/660/1320

SAE-8, 1/2” NPT, 1/2” BSPPSAE-12, 3/4” NPT, 3/4” BSPP 3/4” SAE, Code 62SAE-20, 1 1/4” NPT, 1 1/4” BSPP 1 1/4” SAE, Code 62SAE-24, 1 1/2” NPT, 1 1/2” BSPP2” SAE Flange Code 62

Flow Direction Inlet: Side Outlet: SideConstruction Materials Head Bowl (30-660) Housing/Bowl (660-1320 - 2.0) Cap/Lid (660-1320 type)

Ductile ironSteelSteelSteel

Flow Capacity 30 60 110 160 240 280 330 660 1320

8 gpm (30 lpm)16 gpm (60 lpm)29 gpm (110 lpm)42 gpm (160 lpm)63 gpm (240 lpm)74 gpm (280 lpm)87 gpm (330 lpm)174 gpm (660 lpm)200 gpm (757 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue Pressure

6090 psi (420 bar)6090 psi (420 bar) @ 1 million cycles

Burst Pressure 3060/110160/240/280330/660/1320

15950 psi (1100 bar)17400 psi (1200 bar)17110 psi (1180 bar)15080 psi (1040 bar

Element Collapse Pressure RatingBH4HC, VON, W/HC

3045 psid (210 bar)290 psid (20 bar)

Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.Indicator Trip Pressure��∆P = 29 psid (2 bar) -10% (optional)��∆P = 72 psid (5 bar) -10% (standard)��∆P = 116 psid (8 bar) -10% (optional non bypass)

Bypass Valve Cracking Pressure��∆P = 43 psid (3 bar) +10% (optional)��∆P = 87 psid (6 bar) +10% (standard) Non Bypass Available

Page 3: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F3

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeDF ON 30 T B 5 D 1 . X / 12 - V B6 L24.

Filter Type DF = Inline filter

Element Media ON = Optimicron® BH/HC = Betamicron® (High Collapse) W/HC = Wire Mesh V = Metal Fiber

Size 30, 60, 110, 160, 240, 280, 330, 660, 1320

Pressure Range T = 420 bar

Size and Nominal Connection B = 1/2” Threaded (size 30 only) I = 3/4” SAE Code 62 Flange (sizes 60-140 only) C = 3/4” Threaded (sizes 60-140 only) J = 1 1/4” SAE Code 62 Flange (sizes 160-280 only) E = 1 1/4” Threaded (sizes 160-280 only) L = 2” SAE Code 62 Flange (sizes 330-1320 only) F = 1 1/2” Threaded (sizes 330-1320 only)

Filtration Rating (microns) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = BH/HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V

Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)

Type Number 1 = One piece bowl (sizes 30-660 only) 2 = Two piece bowl (sizes 660-1320 only) 3 = Upside down mount (two-piece bowl) - (sizes 330-1320)

Modification Number (latest version always supplied)

Port Configuration 0 = BSPP 3 = NPT ports – NPT ported filters will be SAE with adaptors in each port 12 = SAE straight thread O-ring boss ports 16 = SAE flange ports (sizes 60-1320 only)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Bypass Valve (omit) = Non-bypass B3 = Bypass (3 bar) B6 = Bypass (6 bar)

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids SO155H = Modification of BH4HC (High Collapse) Element For Phosphate Esters SO184 = G-1/2 Drain in Bowl Option For Sizes 60 - 280 (comes standard for sizes 330, 660, & 1320) W = “VD…” indicator modified with a brass piston for use with High water based emulsions/solutions (HFA) & (HFC)

or when using “V” elements L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100ºF (C and D indicators only) cRUus = Electrical Indicators with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Replacement Element Model Code0030 D 005 ON / V .

Size 0030, 0060, 0110, 0160, 0240, 0280, 0330, 0660, 1320

Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON 25, 74, 149 = W/HC 3, 5, 10, 20 = V

Element Media BH4HC, ON, W/HC, V

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) W = Modication of “V” elements for use with oil water

emulsions (HFA) and water polymer solutions (HFC) usually polyglycol

SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 5 D . X / V L24 .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 15 psid (1 bar) & 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch – SPDT D = Electric switch and LED light – SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicators with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with High water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 4: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F4

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 30

Weight (lbs.) 5.1

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 30

2.7369.3

1.5038

for element removalClearance required

[2.95]

Mounting Holes [0.24]

75

INLET

10-32UNF-2B IN. x 6 DP

OUTLET

1/2" Port4 Places

2.68 68

1.77 45

1.1830

Indicator Port G 1/2"

1/2" NPT optional w/ adapters3/4-16UNF-2B IN.2 Places

Optional G1/4"Drain Port

762.99

2.06

6 0.24

168

52.2

6.61

HEX 0.9424

Page 5: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F5

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 60 110 160 240 280 330

Weight (lbs.) 10 12 22.8 26.1 36 54.1

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 60-330

c1

c2

Flange2 Places

d5 x †2

G 1/2"Indicator Port

OUTLET INLET

Optional G 1/2"Drain Port

h2

HEX

d2

h1

0.24

6

requiredfor element

removal

Clearanceh4

d32 Places

b1

b3

b4

d1 b2

Mounting Holesd4 x †1

4 Places

Page 6: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F6

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size b1 b2 b3 b4 c1 c2 d1 d2d3

NOM d4* d5 h1 h2 h4 HEX †1 †260...C...

1.X(3.54)

90(2.8) 71

(2.2) 56

(1.26) 32 - - (3.39)

86(2.68)

683/4"

1/4-28UNF- 2B

M6x1.0

- (7.22) 183.5

(1.57) 40

(3.35) 85

(1.06) 27

(0.35) 9 -

60...I... 1.X

(3.50) 89

(2.8) 71

(2.2) 56

(1.26) 32

(2.00) 50.8

(0.94) 23.8

(3.39) 86

(2.68) 68

3/8-16UNC- 2B M10 X 1.5

(7.22) 183.5

(1.57) 40

(3.35) 85

(1.06) 27

(0.35) 9

(0.59) 15

110...C... 1.X

(3.54) 90

(2.8) 71

(2.2) 56

(1.26) 32 - - (3.39)

86(2.68)

683/4"

1/4-28UNF- 2B

M6x1.0

- (9.88) 251

(1.57) 40

(3.35) 85

(1.06) 27

(0.35) 9 -

110...I... 1.X

(3.50) 89

(2.8) 71

(2.2) 56

(1.26) 32

(2.00) 50.8

(0.94) 23.8

(3.39) 86

(2.68) 68

3/8-16UNC- 2B M10 X 1.5

(9.88) 251

(1.57) 40

(3.35) 85

(1.06) 27

(0.35) 9

(0.59) 15

160...E... 1.X

(4.92) 125

(3.74) 95

(3.35) 85

(1.38) 35 - - (4.69)

119(3.74)

951-

1/4"

3/8-24UNF- 2B

M10x1.5

- (9.57) 243

(1.85) 47

(4.13) 105

(1.26) 32

(0.55) 14 -

160...J... 1.X

(4.92) 125

(3.74) 95

(3.35) 85

(1.38) 35

(2.63) 66.7

(1.25) 31.8

(4.69) 119

(3.74) 95

1/2-13UNC- 2B

M14 X 2

(9.57) 243

(1.85) 47

(4.13) 105

(1.26) 32

(0.55) 14

(0.75) 19

240...E... 1.X

(4.92) 125

(3.74) 95

(3.35) 85

(1.38) 35 - - (4.69)

119(3.74)

951-

1/4"

3/8-24UNF- 2B

M10x1.5

- (11.91) 302.5

(1.85) 47

(4.13) 105

(1.26) 32

(0.55) 14 -

240...J... 1.X

(4.92) 125

(3.74) 95

(3.35) 85

(1.38) 35

(2.63) 66.7

(1.25) 31.8

(4.69) 119

(3.74) 95

1/2-13UNC- 2B

M14 X 2

(11.91) 302.5

(1.85) 47

(4.13) 105

(1.26) 32

(0.55) 14

(0.75) 19

280...E... 1.X

(4.92) 125

(3.74) 95

(3.35) 85

(1.38) 35 - - (4.69)

119(3.74)

951-

1/4"

3/8-24UNF- 2B

M10x1.5

- (19.06) 484

(1.85) 47

(4.13) 105

(1.26) 32

(0.55) 14 -

280...J... 1.X

(4.92) 125

(3.74) 95

(3.35) 85

(1.38) 35

(2.63) 66.7

(1.25) 31.8

(4.69) 119

(3.74) 95

1/2-13UNC- 2B

M14 X 2

(19.06) 484

(1.85) 47

(4.13) 105

(1.26) 32

(0.55) 14

(0.75) 19

330...F... 1.X

(6.30) 160

(5.24) 133

(4.53) 115

(2.36) 60 - - (6.42)

163(5.12) 130

2"1/2-

20UNF- 2B M12x1.75

- (12.16) 309

(2.05) 52

(4.53) 115

(1.42) 36

(0.67) 17 -

330...L... 1.X

(6.30) 160

(5.24) 133

(4.53) 115

(2.36) 60

(3.81) 96.8

(1.75) 44.5

(6.42) 163

(5.12) 130

3/4-10UNC- 2B M2O X 2.5

(12.16) 309

(2.05) 52

(4.53) 115

(1.42) 36

(0.67) 17

(0.98) 25

330...F... 2.X

(6.30) 160

(5.24) 133

(4.53) 115

(2.36) 60 - - (6.42)

163(5.12) 130

2"1/2-

20UNF- 2B M12x1.75

- (12.16) 309

(2.05) 52

(7.09) 180

(1.42) 36

(0.67) 17 -

330...L... 2.X

(6.30) 160

(5.24) 133

(4.53) 115

(2.36) 60

(3.81) 96.8

(1.75) 44.5

(6.42) 163

(5.12) 130

3/4-10UNC- 2B M2O X 2.5

(12.16) 309

(2.05) 52

(7.09) 180

(1.42) 36

(0.67) 17

(0.98) 25

*d4 - UN Threads for SAE (/12) & Flanged (/16) ports - M Threads for BSPP ports & Flanged metric ports

Dimensions DF 60-330 (cont’d)

Notes

Page 7: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F7

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size b1 b2 b3 b4 c1 c2 d1 d2d3

NOM d4* d5 h1 h2 h4 HEX †1 †2660...F...

1.X(6.3) 160

(5.24) 133

(4.53) 115

(2.36) 60 - - (6.42)

163(5.12) 130

1- 1/2" 1/2-

20UNF- 2B M12x1.75

- (18.93) 481

(2.05) 52

(4.53) 115

(1.42) 36

(0.67) 17 -

660...L... 1.X

(6.3) 160

(5.24) 133

(4.53) 115

(2.36) 60

(3.81) 96.8

(1.75) 44.5

(6.42) 163

(5.12) 130 2"

3/4-10UNC- 2B

M20x2.5

(18.93) 481

(2.05) 52

(4.53) 115

(1.42) 36

(0.67) 17

(0.98) 25

660...F... 2.X

(6.3) 160

(5.24) 133

(4.53) 115

(2.36) 60 - - (6.42)

163(5.12) 130

1- 1/2" 1/2-

20UNF- 2B M12x1.75

- (18.54) 471

(2.05) 52

(4.53) 115

(1.42) 36

(0.67) 17 -

660...L... 2.X

(6.3) 160

(5.24) 133

(4.53) 115

(2.36) 60

(3.81) 96.8

(1.75) 44.5

(6.42) 163

(5.12) 130 2"

3/4-10UNC- 2B

M20x2.5

(18.54) 471

(2.05) 52

(4.53) 115

(1.42) 36

(0.67) 17

(0.98) 25

1320...F... 2.X

(6.3) 160

(5.24) 133

(4.53) 115

(2.36) 60 - - (6.42)

163(5.12) 130

1- 1/2" 1/2-

20UNF- 2B M12x1.75

- (29.25) 743

(2.05) 52

(26.38) 670

(1.42) 36

(0.67) 17 -

1320...L... 2.X

(6.3) 160

(5.24) 133

(4.53) 115

(2.36) 60

(3.81) 96.8

(1.75) 44.5

(6.42) 163

(5.12) 130 2"

3/4-10UNC- 2B

M20x2.5

(29.25) 743

(2.05) 52

(26.38) 670

(1.42) 36

(0.67) 17

(0.98) 25

Size 660 1.0 660 2.0 1320 2.0

Weight (lbs.) 70 75.9 112.7

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 660-1320

d1

h4Clearance required for element removal

Portd5 x t2IndicatorG 1/2"

G 1/2"Drain Port

5.98

c2

152

c1

h1

4.41112

d2

Inlet

b4

b3 b2

b1

[Mounting Bolts]d4 x t1

4 Places

INLETOUTLET

INLET

G 1/2"Indicator Port

OUTLET

d2 h1

h2

0.24

6

HEX G 1/2" Drain Port

d32 Places

b1

660 1.0 Version 660-1320 2.0 VersionNote - See 1.X Version for mounting

Page 8: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F8

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 330 660 1320Weight (lbs.) 61.5 74.8 112.0

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 330/660/1320 3.0 Version

Threaded Port

1-7/8-12UN-2BSAE-24 Port

h1

2.0552

0.24

6

5.87149

HEX1.4236

3.8196.8

1.7544.5

SAE-1.26

32 FlangeCode 62 (2")

[1.06]HEX 27

[0.39]HEX 10Vent PortG1/2"

2.3660

4.53115

M12X22/27

deep0.4010.2

6.42163

5.20132

5.98152

HEX 8 Drain Port G3/8"

6.30160

INLETOUTLET

∆ P CloggingIndicator CavityG 1/2"

h4Clearance required forelement removal

Size h1 h4330...F..3.X [10.35]

263[3.15]

80330...L..3.X660...F..3.x [16.85]

428[9.84] 250660...L..3.x

1320...F..3.x [29.49] 749

[22.44] 5701320...L..3.x

Page 9: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F9

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

00

3

6

9

12

15

0

0.2

0.4

0.6

0.8

1.0

3 6 9 12

0 10 20 30 40

Q (gpm)

DF 30 Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

3

15

6

9

12

0

0.2

0.6

0.4

0.8

1.0

5 10 15 20 25 30

0 20 40 60 80 100

Q (gpm)

DF 60/110 Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

5

10

15

0

0.2

0.4

0.6

0.8

1.0

20 40 60 80 100

0 50 100 150 200 250 300 350

Q (gpm)

DF 160/240/280 Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

5

15

10

0

0.4

0.2

0.6

0.8

1.0

40 80 120 160 200

0 200100 300 400 500 600 700

Q (gpm)

DF 330/660/1320 Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Metal Fiber …D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0030 D XXX V 1.011 0.740 0.411 0.2000060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.1180160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012

Wire Mesh …D…W/HC ElementsSize 25, 50, 74, 100, 149, 200 µm

0030 D XXX W/HC 0.1660060 D XXX W/HC 0.0420110 D XXX W/HC 0.2300160 D XXX W/HC 0.0160240 D XXX W/HC 0.0100280 D XXX W/HC 0.0090330 D XXX W/HC 0.0080660 D XXX W/HC 0.0041320 D XXX W/HC 0.002

Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

0030 D XXX ON 4.27 3.507 2.376 1.251 0.768 0.620060 D XXX ON 2.936 1.427 1.004 0.664 0.537 0.3470110 D XXX ON 1.416 0.735 0.527 0.333 0.254 0.1640160 D XXX ON 1.015 0.604 0.423 0.225 0.204 0.1750240 D XXX ON 0.631 0.379 0.293 0.175 0.134 0.1150280 D XXX ON 0.304 0.185 0.15 0.082 0.075 0.0640330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015

Betamicron® ...D...BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0030 D XXX BH4HC 5.005 2.782 1.992 1.0430060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.3070160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022

All Element K Factors in psi / gpm.

Page 10: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F10

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Gearboxes

Industrial

Pulp & Paper

Offshore

Railways

CommercialMunicipal

Shipbuilding

PowerGeneration

Steel / HeavyIndustry

Features• Available in T ported or L ported configurations• Handles high flows to 250 GPM (pricing competitive)• Available in bidirectional flow and single flow configurations• Two part bowl for ease of operation and element

change-out• Filter head made of ductile iron• Filter housing (bowl) and lid made of steel• Can mount head on top with bottom access (2.x) or head

on bottom with top access (3.x)• Single flow version (DF) can be supplied with bypass

(located in head assembly).• Bidirectional flow version (DFF) can only be supplied with

no-bypass.

DF/DFF 1500 SeriesInline Filters6090 psi • up to 250 gpm

INLET

OUTLET

BypassValve

FilterElement

Pop-upIndicator

DFF FILTERREVERSE FLOW

CIRCUIT

Technical SpecificationsMounting Method 4 Mounting holes

in the filter head - M-12 ThreadsPort Connection SAE-32 four bolt code 62 Flange

(DN 50) with metric bolt threads (M20 x 30mm deep) 2” SAE 32 straight thread O-Ring Boss / 2” BSPP thread

Flow Direction Side inlet and outlet - Indicator on top Side inlet and top outlet - Indicator on side

Construction Materials Head: Ductile Iron (GGG40)Filter housing (bowl) & lid: Steel

Flow Capacity 250 gpm (950 lpm)Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

6090 psi (420 bar)6090 psi (420 bar) @ 300,000 cyclesContact HYDAC

Element Collapse Pressure RatingON, W/HCBH4HC, V

290 psid (20 bar)3045 psid (210 bar)

Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)

Fluid CompatibilityCompatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected

Indicator Trip Pressure∆P = 29 psid (2 bar) -10%∆P = 72 psid (5 bar) -10%∆P = 116 psid (8 bar) -10% (non-bypass)

Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10%∆P = 87 psid (6 bar) +10%Non Bypass Available

Page 11: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F11

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Clogging Indicator Model CodeVD 5 B . X / V .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 15 psid (1 bar) & 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch – SPDT D = Electric switch and led light – SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicators with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with High water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Replacement Element Model Code 1500 D 010 BH4HC / V Size 1500

Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = BH4HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V

Element Media ON, BH4HC, W/HC, V Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) SO155H = (same as above) W = Modification of “V” elements for use with oil/water

emulsions (HFA) and water polymer (usually polyglycol) solutions (HFC)

SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Model CodeDF BH/HC 1500 T G 10 B 2 . X / 12 V .

Filter Type DF = Inline filter DFF = Inline filter - Reverse flow

Element Media ON = Optimicron® BH/HC = Betamicron® (High Collapse) (required on DFF) W/HC = Wire Mesh V = Metal Fiber

Size and Nominal Connection 1500 = 2” BSPP / SAE 32 Straight Thread / 2” SAE DN 50 Flange

Pressure T = 6090 psi / 420 bar

Type of Head (omit) = T Port L = L Port

Type of Connection G = 2” Threaded L = 2” Flanged SAE DN 50

Filtration Rating (microns) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = BH/HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V

Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)

Type Number 2 = Standard Mounting - Bottom Accessible (two-piece bowl) 3 = Upside Down Mounting w/o Drain Port in Head (two-piece bowl) - (cust. to supply low point drain external to filter)

Modification Number (latest version always supplied)

Port Configuration (omit) = 2” SAE DN 50 Flange Ports (metric bolt threads M20) 0 = 2” BSPP 12 = 2” SAE Straight Thread O-Ring Boss Ports

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Bypass Valve (omit) = Without Bypass (BH4HC or “V” High Collapse elements recommended)) B3 = 43 psid Bypass (optional)

No bypass on DFF 1500

B6 = 87 psid Bypass (standard)

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids SO155H = Modification of BH4HC (High Collapse) Element For Phosphate Esters W = “VD…” indicator modified with a brass piston for use with High water based emulsions/solutions

(HFA) & (HFC) or when using “V” elements L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100ºF (C and D indicators only) cRUus = Electrical Indicators with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Page 12: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F12

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size DF/DFF 1500 2.0 “L”

Weight (lbs.) 152.8

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF/DFF 1500 2.0 L Configuration

1766.93

0.24

6 0.9825

2.3660

Mounting Pattern

[27.56] 700Clearance required for element removal

OUTLET

SAE 6000PSIDN 50

INLET

Mounting Surface

122 4.80

6.93

3.8698

6.00

36 HEX

983.86

176

152.4

34.76883

M12x1.75x 22 DP

4.33110

2.1354

1.7544.5

3.81

96.8

5.28134

Drain PortG 1/2"

INLET

3.81 96.8

1.7544.5

M20x2.5x 30 DP

G 1/2"IndicatorPort

Page 13: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F13

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size DF/DFF 1500 3.0 “L”

Weight (lbs.) 152.6

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF/DFF 1500 3.0 L Configuration

6.93176

SAE 6000PSIDN 50

3.86

34.76883

152.4

6.93

6.00

98 3.86

176

HEX 36

98

4.80122

INLET

Vent PortG 1/2"

OUTLET

4.33110

2.1354

M12x1.75x 22 DP

0.9825

3.81 5.28 134

6 0.24

96.8

1.7544.5

OUTLET

Inlet

96.8

2.363.81 60

1.7544.5

M20x2.5x30 DP

G 1/2"Indicator Port

Page 14: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F14

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Dimensions DF/DFF 1500 2.0 T Configuration

6.93176

Drain PortG1/2"

INLET

44.51.75

3.8196.8

M20x2.5x 30 DP

x 22 DP

134 110

M12x1.75

2.13

1967.72

54

5.284.33

1.06 27

Hex1.0627

Threaded Version

2-1/2"-12UN-2B IN.SAE-32 Port2 Places

[27.56] 700

Mounting Pattern

Clearance requiredfor element removal

G 1/2"

INLET

Indicator Port

OUTLET

6

34.76

4.80

0.24

6.00152.4

36 HEX

2.36

883

60

122

6.93176

Size DF/DFF 1500 2.0 “T”

Weight (lbs.) 152.8

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Page 15: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F15

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Dimensions DF/DFF 1500 3.0 T Configuration

6.93176

2-1/2"-12UN-2B IN.SAE 32 Port2 Places

G 1/2" Indicator Port

34.29

152.4

124

6.00

871

4.88

60.24

HEX 36

700[27.56]

Clearance requiredfor element removal

Threaded Version

Mounting Pattern

134

5.28

196 7.72

x 23 DPM12x1.75

1104.33

2.1354

HEX1.0627

G1/2"Vent Plug

96.8

6.93

3.81

176

1.7544.5

M20x2.5x 30 DP

INLET OUTLET

Size DF/DFF 1500 3.0 “T”

Weight (lbs.) 152.6

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Page 16: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F16

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Flow in l/min

Flow in gpm

DF 1500

0 50 100 150 200 250

0 200 400 600 800

0

10

20

30

40

50

Forward

Reverse

0

1.0

0.5

1.5

2.0

2.5

3.0

3.5

Flow in l/min

Flow in gpm

DFF 1500

0

0.4

0.8

1.2

1.6

0 200 400 600 800 1000

0

5

10

15

20

25

0 50 100 150 200 250 300

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors

∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x Actual Viscosity (SUS) x Actual Specific Gravity

(From Tables Below) 141 SUS 0.86

Optimicron …D…ON (Pressure Elements)Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

1500 D XXX ON 0.09 0.053 0.038 0.026 0.02 0.015

Betamicron ...D…BH4HC (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

1500 D XXX BH4HC 0.077 0.044 0.033 0.027

Wire Mesh ...D…W/HC Elements Size ...D…W/HC Elements 25, 50, 74, 100, 149, 200 µm

1500 D XXX W/HC 0.020

Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

1500 D XXX V 0.016 0.011 0.011 0.005

All Element K Factors in psi / gpm.

Page 17: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F17

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Notes

Page 18: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F18

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Industrial

Railways

Features• DFFX Reverse Flow models filter fluid in the forward direction and

bypass the filter element when the flow direction is reversed.• O-ring seals are used to provide positive, reliable sealing. Choice

of O-ring materials provide compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.

• Screw-in bowl/lid mounted below the filter head requires minimal clearance to remove the element for replacement; contaminated fluid cannot be washed downstream when element is serviced.

• Clogging indicators have no external dynamic seal. This results in high reliability due to magnetic actuation which eliminates a leak point.

• A poppet-type bypass valve (optional) located in the filter head provides positive sealing during normal operation and fast opening during cold starts and flow surges.

DFFX SeriesReverse Flow Differential Pressure Optimized Filters6090 psi • up to 160 gpm

or

DFFX FILTERREVERSE FLOW

CIRCUIT

BY-PASSVALVES

(OPTIONAL)

∆P Indicator

Reverse Flow Valve

OUTLETINLET

Technical SpecificationsMounting Method 4 mounting holesPort ConnectionDFFX 330/660/1320 2” SAE Flange Code 62

Flow Direction Inlet: Side Outlet: Side or TopConstruction MaterialsHeadSingle piece bowl “1.X” BowlTwo piece bowl “2.X” Housing Lid/Cap

Ductile iron

Steel

SteelSteel

Flow Capacity330660/1320

80 gpm (303 lpm)100 gpm (379 lpm)/160 gpm (606 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

6090 psi (420 bar)Contact HYDAC OfficeContact HYDAC Office

Element Collapse Pressure RatingBH4HC, VON, W/HC

3045 psid (210 bar)290 psid (20 bar)

Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)

Fluid CompatibilityCompatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) -10% (optional)

Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)Non Bypass Available

Page 19: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F19

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeDFFX BN/HC 1320 T L L 3 BM 2 . X / 16 V .

Filter Type DFFX = Reverse Flow Bypass Filter

Element Media ON = Optimicron® BH/HC = Betamicron® (High Collapse) W/HC = Wire Mesh V = Metal Fiber

Size and Nominal Connection 330 = 2” Flange SAE Code 62 660 = 2” Flange SAE Code 62 1320 = 2” Flange SAE Code 62

Pressure Range T = 6000 psi (414 bar)

Head Design (omit) = T head L = L Head

Size and Nominal Configuration L = 2” SAE Code 62 Flange)

Filtration Rating (microns) 3, 5, 10, 20 = BH/HC 1, 3, 5, 10, 15, 20 = ON 25, 74, 149 = W/HC 3, 5, 10, 20 = V

Type of ∆P Clogging Indicator A, BM, C, D (others available upon request)

Type Number 1 = One piece bowl (sizes 330-660 only 2 = 2 Piece Bowl (size 660 - 1320) 3 = Upside-down Mounting (size 660 - 1320)

Modification Number (latest version always supplied)

Port Configuration 16 = SAE flange ports

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Bypass Valve (omit) = Non-bypass – Critical applications (high collapse element required) B3 = 43 psid (3 bar) (Optional) B6 = 87 psid (6 bar) (Standard setting for pressure filters)

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

or when using “V” elements L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100ºF (C and D indicators only) cRUus = Electrical Indicators with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Replacement Element Model Code1320 D 003 BH4HC / V .

Size 0330, 0660, 1320

Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = BH4HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V

Element Media BH4HC, ON, W/HC, V

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 8 BM . X / V .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) 8 = 116 psid (8 bar)Type of Indicator A = No indicator, plugged port BM = Pop-up indicator (manual reset) C = Electric switch – SPDT D = Electric switch and LED light – SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EP = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L48 = 48V L110 = 110V L220 = 220V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicators with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 20: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F20

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 330 TL1.0v 660 TL1.0vWeight (lbs.) 109.2 124.8

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFX 330 / 660 TL 1.X Version

0.24

6

3.15

5.13130.2

3.5490

HEX36

1.42

80

0.16

4

Vent PlugG 1/2"

OUTLET

174

75

3.2382

2.95

6.85

1.7745

2 PL'S

for element removal

G 1/2"

Code 62 Flange

Port

Drain Plug

115

[4.53]

Clearance required

INLET

2" SAE

G 1/2" CloggingIndicator

1.75±0.01

346.5

96.8±0.2

2.56

DFFX 330:

149

3.81±0.0182

5.87

3.23

3.94

100

44.5±0.2

2.24

65

57

[20.35]

13.64

DFFX 660: 517

[1.00]3/4"-10UNC-2Bx25.3 DP

7.28185

210

9.02

20

8.27

150

229

6.69

200.79

5.91 170

1/2"-20UNF-2Bx20 DP

0.79

[0.78]

0.16

4

Page 21: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F21

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 330 TLL1.0v 660 TLL1.0vWeight (lbs.) 109.2 124.8

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFX 330 / 660 TLL 1.X Version

required

Indicator

Port

removal

G1/2" Clogging

for element

[4.53]115Clearance

3.15 80

5.13130.2

HEX

DFFX 330: 346.5

1.4236

DFFX 660:

5.79

20.35517

129 5.08

147

[13.64]

7.28185

OUTLET

G1/2"Drain Plug

6.46

164

2.9575

823.23

0.24

6

2" SAECode 62 Flange 2 PL'SINLET

2.56

229

65

96.8±0.2

1.75±0.01

[1.00]

9.02

3/4"-10UNC-2Bx25.3 DP

3.81±0.01

44.5±0.2

3.2382

8.27

210

200.79

25

0.98

6.10155

[0.79]1/2"-20UNFx20 DP4 PL'S

Page 22: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F22

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 660 TL2.0_3.0v 1320 TL2.0_3.0vWeight (lbs.) 124.8 167.8

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFX 660 / 1320 TL 2.X & 3.X Version

CloggingG 1/2"

Indicator

Drain plug

port

G1/2"

2" SAE Code 62 Flange2 PL'SINLET

65

100

3.81±0.01

2.56

2.24

44.5±0.2

7.28

96.8±0.2

1.75±0.013.94

185

57

3.23

82

5.87149

[1.00]3/4"-10UNC-2Bx25.3 DP

DFFX 1320: 570 MIN

Vent plug

Drain plugG 1/2"

G1/2"

Clearance requiredfor element removal

[9.84]DFFX 660: 250 MIN [22.44]

5.98152

361.42

20.31DFFX 660:

HEX

DFFX 1320: 838 [32.99]

516

5.87149

AS 2.X VERSION

660-1320 3.XFILTER HEAD SAME

Clearance requiredfor element removal

DFFX 1320: 670 MIN

[13.78]DFFX 660: 350 MIN [26.38]

DFFX 1320: 831

1525.98

[32.72]

3.15

5.20132

20.04

HEX36

509

1.42

0.246

803.54

90

DFFX 660:

1124.41

0.16

4

210 8.27

0.79

0.79

20

5.91 6.69

[0.78]

170

1/2"-20UNF-2Bx20 DP

20

150

9.02229

Vent plugG1/2"

OUTLET

3.23

1.77174

82

6.85

45

2.9575

660 / 1320 2.X Version

Page 23: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F23

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 660 TLL2.0v 1320 TLL2.0vWeight (lbs.) 124.8 167.8

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFX 660 / 1320 TLL 2.X Version

for element removal

DFFX 1320: 670

G1/2" Clogging

Clearance required

PortIndicator

[13.78]DFFX 660: 350 [26.38]

112

509

4.41

20.04

1475.79

129

DFFX 660:

5.08

5.20

132

7.28185

1.42

[32.72]DFFX 1320: 831

HEX

5.98152

36

3.1580

2" SAECode 62 Flange2 PL'SINLET

1.75±0.01 3/4"-10UNC-2Bx25.3 DP44.5±0.2

65

9.02

2.56

3.81±0.01

229

96.8±0.2

[1.00]

3.2382

OUTLET

G1/2"Drain Plug

1646.46

75

6

2.95

0.24

3.2382

155

0.9825

8.27 210

6.10

0.7920

[0.79]1/2"-20UNFx20 DP4 PL'S

Page 24: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F24

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

DFFX 330 / 660 / 1320 TL Housing

Forward

Reverse

0

20

25

15

10

5

0.0

1.6

1.2

0.8

0.4

0 40 80 120 160 200

0 300200100 400 500 600 700

Flow in gpm

DFFX 330 / 660 / 1320 TLL Housing

Forward

Reverse

0

20

25

15

10

5

0.0

1.6

1.2

0.8

0.4

0 40 80 120 160 200

0 300200100 400 500 600 700

Flow in gpm

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Metal Fiber …D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012

Wire Mesh …D…W/HC ElementsSize 25, 50, 74, 100, 149, 200 µm

0330 D XXX W/HC 0.0080660 D XXX W/HC 0.0041320 D XXX W/HC 0.002

Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

0330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015

Betamicron ...D...BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022

All Element K Factors in psi / gpm.

Page 25: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F25

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Notes

Page 26: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F26

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Gearboxes

Industrial

Pulp & Paper

Offshore

Railways

CommercialMunicipal

Shipbuilding

PowerGeneration

Steel / HeavyIndustry

Features• Non-welded housing design reduces stress concentrations and

prevents fatigue failure.• Choice of SAE straight thread O-ring boss, and straight thread

BSPP (sizes 300 - 900) to allow easy installation without costly adapters.

• O-ring seals are used to provide positive, reliable sealing. We offer a choice of O-ring materials (Nitrile rubber or Fluorocarbon elastomer), to provide compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.

• Screw-in bowl mounted below the filter head requires minimal clearance to remove the element for replacement and contaminated fluid cannot be washed downstream when element is serviced.

• HYDAC Differential Pressure Indicators have no external dynamic seal. This results in a high system reliability due to magnetic actuation, thus eliminating a potential leak point.

• A poppet-type bypass valve (optional) provides positive sealing during normal operation and fast opening during cold starts and flow surges.

• The HDF is available with a bypass valve. The HDFF is offered in non bypass only.

• Fatigue pressure ratings equal maximum allowable working pressure rating.

• Inlet/outlet ports in “L” configuration • No element valve-only available with HDF in “L” configuration.

HDF/HDFF SeriesInline Filters & Inline Filters With Reversible Flow4060 psi • up to 100 gpm

Technical SpecificationsMounting Method 4 mounting holesPort Connection 300, 450, 650, 900: 1” SAE-16 parallel straight thread or

1” BSPP or1 1/4” SAE-20 parallel straight thread or 1 1/4” BSPP or1 1/2” SAE-24 parallel straight thread or 1 1/2” BSPP

Flow Direction Inlet: Side Outlet: Top Construction Materials Head Bowl

Ductile ironSteel

Flow Capacity 300 450 650 900

30 gpm (114 lpm)60 gpm (227 lpm)90 gpm (340 lpm)100 gpm (378.5 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue Pressure

4060 psi (280 bar)4060 psi (280 bar) @ 1 million cycles6090 psi (420 bar) @ 250,000 cycles

Burst Pressure (Consult HYDAC)

Element Collapse Pressure RatingBH4HC ON

3045 psid (210 bar)290 psid (20 bar)

Fluid Temp. Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.Indicator Trip Pressure��∆P = 29 psid (2 bar) -10% (optional)��∆P = 72 psid (5 bar) -10% (standard)��∆P = 116 psid (8 bar) -10% (optional non bypass)

Bypass Valve Cracking Pressure��∆P = 43 psid (3 bar) +10% (optional-HDF only)��∆P = 87 psid (6 bar) +10% (standard) Non Bypass Available for HDF (HDFF available only with no bypass)

A

B

A

B

Page 27: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F27

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeHDF BH/HC 450 O L E 10 D 1 . X / 12 V .

Filter Type HDF or HDFF (HDFF on request)

Element Media ON = Optimicron® BH/HC = Betamicron® (High Collapse) Size 300, 450, 650, 900

Pressure Range O = 4060 psi (280 bar); 6090 psi (420 bar) at 250,000 cycles

Type of Connection L = Flow path in L-configuration (standard version)

Size and Nominal Connection D = 1” Threaded E = 1 1/4” Threaded F = 1 1/2” Threaded

Filtration Rating (microns) 3, 5, 10, 20 = BH/HC 1, 3, 5, 10, 15, 20 = ON

Type of ∆P Clogging Indicator A, BM, C, D, Y

Type Modification Number 1

Modification Number (latest version always supplied)

Port Configuration 0 = BSPP straight thread 12 = SAE parallel straight thread o-ring boss ports

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Bypass Valve (omit) = Non-bypass - critical applications (high collapse element required) B3 = 43 psid (3 bar) - optional B6 = 87 psid (6 bar - standard setting for pressure filters)

Supplementary Details L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) LED = 2 light-emitting diodes up to 24 Volt (only for clogging indicator type “D”) NEV = No Element valve (only for HDF filters in L-configuration) SO184 = pressure release drain screw (G-1/2”) SFREE = Element specially designed to minimize electrostatic charge generation W = “VD…” indicator modified with a brass piston for use with high water based

emulsions/solutions (HFA) & (HFC) or when using “V” elements

Replacement Element Model Code0450 D 010 BH4HC / V .

Size 0300, 0450, 0650, 0900

Type D

Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON

Element Media BH4HC, ON

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Supplementary Details W = (same as above) SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 8 D . X / V .

Indicator Prefix VD = differential pressure

indicator up to 420 bar operating pressure

Pressure setting 5 = standard 5 bar (for HDF filters) 8 = standard 8 bar (for HDFF filters) Others available upon request

Type of Indicator A = No indicator, plugged port BM = Pop-up indicator (manual reset) C = Electric switch – SPDT D = Electric switch and LED light – SPDT Y = Plastic blanking plug in indicator port

Modification Number (latest version always supplied)

Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Light Voltage (D type indicators only) L24 = 24V L110 = 110V

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 28: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F28

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 300 450 650 900

Weight (lbs.) 24.7 28.9 35.8 47.4

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions HDF/HDFF 300-900

d3 t1

d3

G 1/2"Indicator Port ∆ P Clogging

Drain Port (Optional)G 1/2" -(SO184)

h1

1.26

4.14

32

105.2

57

HEX

t1 INLET Port

OUTLETPort

632.48

88.95.16

131.1

2.8372

42.9

2

3.50

1.69

Mounting Holesd4 x t2

4 Places

HDF/HDFF h1

300 [9.680]246

450 [13.35]339

650 [18.11]460

900 [22.28]566

ød3 †1 ød4 †2

G1 [0.71]18

M10 X 1.5 [0.71]18G1-1/4 [0.79]

20

G1-1/2 [0.87]22

SAE-16 [0.75]19

3/8-24UNF-2B [0.55]14SAE-20 [0.75]

19

SAE-24 [0.75]19

Page 29: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F29

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

00

1

2

3

5

4

7

6

10

9

8

0

0.2

0.4

0.6

0.1

0.3

0.5

10 3020 50 6040 70 9080 100

0 50 100 150 200 250 300 350

Q (gpm)

HDF Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

5

10

30

15

20

25

0

0.5

1.0

1.5

2.0

10 20 4030 50 60 70 80 90 100

15050 1000 200 250 300 350

Q (gpm)

HDFF Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors

∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x Actual Viscosity (SUS) x Actual Specific Gravity

(From Tables Below) 141 SUS 0.86

Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

0300 D XXX ON 0.801 0.488 0.391 0.268 0.154 0.1430450 D XXX ON 0.401 0.244 0.193 0.131 0.077 0.0690650 D XXX ON 0.245 0.148 0.121 0.081 0.047 0.0440900 D XXX ON 0.185 0.115 0.092 0.06 0.036 0.035

Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0300 D XXX BH4HC 0.878 0.488 0.390 0.1810450 D XXX BH4HC 0.428 0.236 0.187 0.0880650 D XXX BH4HC 0.258 0.143 0.115 0.0550900 D XXX BH4HC 0.192 0.110 0.088 0.038

All Element K Factors in psi / gpm.

Page 30: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F30

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Industrial

Railways

Features• Non-welded housing design reduces stress concentrations and

prevents fatigue failure.• Inlet/Outlet port options include SAE straight thread O-ring boss,

BSPP and subplate mounting to allow easy installation without costly adapters.

• O-ring seals are used to provide positive, reliable sealing. A choice of O-ring materials (nitrile, fluorocarbon elastomer, ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.

• Screw-in bowl mounted below the filter head requires minimal clearance to remove the element for replacement and contaminated fluid cannot be washed downstream when element is serviced.

• Clogging indicators are actuated by differential pressure and have no external dynamic seal. High reliability is achieved and magnetic indicator actuation eliminates a potential leak point.

• A poppet type bypass valve is typically mounted in the filter head out of the flow path between the inlet and outlet port to provide positive sealing during normal operation and fast response during cold starts and flow surges.

• Fatigue pressure rating equals maximum allowable working pressure rating.

HF2P SeriesInline Filters4000 psi • up to 25 gpm

A

B

Technical SpecificationsMounting Method 2 mounting holesPort Connection SAE-12, 3/4” BSPP,

Manifold Mount – (0.689”)Flow Direction Inlet: Side Outlet: SideConstruction MaterialsHeadBowl

Ductile ironSteel

Flow Capacity4”8”

16 gpm (60 lpm)25 gpm (95 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

4000 psi (276 bar)4000 psi (276 bar) @ 1 million cycles14,680 psi (1012 bar)

Element Collapse Pressure RatingBH4HCBN

3045 psid (210 bar)290 psid (20 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) -10% (optional on bypass)

Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)Non Bypass Available

Page 31: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F31

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeHF2P BN 08 G 3 C 1 . 2 / 12 V - B6 - T100

Filter Type HF2P = Inline pressure filter

Element Media BN = Betamicron® (Low Collapse) BH = Betamicron® (High Collapse)

Element Length 04 = 4 inches 08 = 8 inches

Type of Connection G = Threaded In-Line P = Manifold Mount

Filtration Rating (microns) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BH

Type of Clogging Indicator A, B, BM, C, D, J, J4 (others available upon request)

Type Code 1

Modification Number (the latest version is always supplied)

Port Configuration (omit) = Manifold Filter 12 = SAE 12” straight thread O-ring boss 0 = BSPP straight thread G 3/4” (contact factory for minimum quantity & availability)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Bypass Valve (omit) = Non-bypass - Critical applications (high collapse element required) B3 = 43 psid (3 bar) - Optional B6 = 87 psid (6 bar) (standard)

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Thermal lockout on indicator at 100ºF (C, D, J, and J4 indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Replacement Element Model Code 1 . 07 . 08 D 03 BN / V Length (nominal inches) 04, 08Filtration Rating (micron) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BHElement Media BN, BHSeals (omit) = Nitrile rubber (NBR) (standard)

V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) SFREE = (same as above)

Clogging Indicator Model CodeVD 5 C . X / V .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) (Top mount only) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT J = Electric switch (Brad Harrison 5-pin mini connector) J4 = Electric switch - M12

(Brad Harrison 4-pin micro connector)

Modification NumberSupplementary Details Seals (omit) = Nitrile RUBBER (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 32: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F32

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 04 08

Weight (lbs.) 10.7 14.3

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

3.3986

HEX [0.95]

24

∆P Clogging Indicator Port G 1/2

2.0552

0.8421.4

Clearance requiredfor element removal

75

OUTLETINLET

[2.96]

Mounting Holes [0.27]

6.75Thru2 Places

79.4

4.02

3.86

3.00

3.13

76.2

98

1.00 25.4

[8.43]HF2P-04 214

[12.09]HF2P-08 307

102

0.24

6

Dimensions HF2P Inline Mounting

Page 33: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F33

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 04 08

Weight (lbs.) 10.7 14.3

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

∆P Cloggingindicator portG 1/2

96

HF2P-04 212 [8.34]

104 4.09

3.78

763.00

HF2P-08 305 [12.01]

1.0226

OUTLETINLET

HEX [0.95]

24

3.4186.5

31.81.25

17

0.63

15.9

0.28

0.689

8.6

7

0.67

(4 Places)

3.50 88.9

17.50.689

17.5

1.25 31.8

0.34

Mounting Holes

1.4637

Dimensions HF2P Subplate Mounting

Page 34: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F34

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

141210

8642

1.2

0.8

0.4

0.00 5 10 15 20 25

0 20 40 60 80 100

Q in gpm

Q in l/min

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Autospec HF2 Depth 1.07.08DXXBN (Low Collapse)Size 3 µm 6 µm 12 µm 25µm

1.07.04DXXBN 2.046 1.735 0.925 0.5311.07.08DXXBN 0.975 0.815 0.457 0.257

Autospec HF2 Depth 1.07.08DXXBH (High Collapse)Size 3 µm 6 µm 10 µm 17 µm

1.07.04DXXBH 2.400 1.690 1.027 0.5381.07.08DXXBH 1.165 0.820 0.499 0.262

All Element K Factors in psi / gpm.

Page 35: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F35

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Notes

Page 36: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F36

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Applications

Automotive Construction Industrial Railways

Steel / HeavyIndustry

Features• Non-welded housing design reduces stress concentrations and

prevents fatigue failure.• Inlet/Outlet port options include SAE straight thread O-ring boss,

BSPP and flange mounting to allow easy installation without costly adapters.

• O-ring seals are used to provide positive, reliable sealing. Choice of O-ring materials (nitrile rubber, fluorocarbon elastomer, ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.

• Screw-in bowl or lid (on 2 piece bowls), mounted below the filter head requires minimal clearance to remove the element for replacement, and contaminated fluid cannot be washed downstream when element is serviced.

• Clogging indicators are actuated by differential pressure and have no external dynamic seal. High reliability is achieved and magnetic indicator actuation eliminates a potential leak point.

• A poppet type bypass valve, located in filter head, mounted between the inlet and outlet port to provides positive sealing during normal operation and fast response during cold starts and flow surges, while additionally providing low operating ∆P.

• Fatigue pressure rating equals maximum allowable working pressure rating.

HF3P SeriesInline Filters6090 psi • up to 120 gpm Hydraulic Symbol

A

B

Technical SpecificationsMounting Method 4 mounting holesPort Connection SAE-16, SAE-24, 1” BSPP,

1 1/2” BSPP, 1 1/2” SAE Flange Code 61, 2” SAE Flange Code 62

Flow Direction Inlet: Side Outlet: SideConstruction MaterialsHeadBowlHousing (size 16)Cap (size 16)

Ductile ironSteelSteelDuctile iron

Flow Capacity4”8”13”16”

28 gpm (106 lpm)55 gpm (208 lpm)91 gpm (344 lpm)120 gpm (454 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

6090 psi (420 bar)6090 psi (420 bar) @ 1 million cycles 15,080 psi (1040 bar)

Element Collapse Pressure RatingBHBN

3045 psid (210 bar)290 psid (20 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) -10% (optional)

Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standardNon Bypass Available

Page 37: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F37

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeHF3P BN 08 G 3 B 1.2 / 12 V B7 .

Filter Type HF3P = In-Line pressure filter

Element Media BN = Betamicron® (Low Collapse) BH = Betamicron® (High Collapse)

Element Length 04 = 4 inches (non-standard) 13 = 13 inches 08 = 8 inches 16 = 16 inches (non-standard)

Type of Connection G = Threaded Inline F = Flanged Inline

Filtration Ratings (microns) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BH

Type of ∆P Clogging Indicator A, B, BM, C, D, J, J4

Type Modification Number 1.2 = 2” Flange code 62 or SAE 24” or G 1 1/2 2.1 = 1 1/2” Flange code 61 (this will lower MAWP to 3000 psi (206.8 bar)) 3.1 = 1” SAE 16 or G 1” Threaded (reduced port)

Port Configuration 0 = BSPP Threaded Ports G 1 1/2” or G 1” 12 = SAE straight thread O-ring boss SAE 24” or SAE 16” 16 = SAE flange ports - SAE 2”, code 62 (6000 psi) or 1 1/2” code 61

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Bypass Valve (omit) = without bypass (BH elements recommended) B3 = 3 bar/43 psid B6 = 6 bar/87 psid (standard)

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Thermal lockout on indicator at 100°F (C, D, J, and J4 indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Replacement Element Model Code 1 . 11 . 08 D 03 BN / V Length (nominal inches) 04, 08, 13, 16Filtration Rating (micron) 3, 6, 12, 25 = BN 3, 6, 10, 17 = BHElement Media BN, BHSeals (omit) = Nitrile rubber (NBR) (standard)

V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) SFREE = (same as above)

Clogging Indicator Model CodeVD 5 C . X / V .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT J = Electric switch (Brad Harrison 5-pin mini connector) J4 = Electric switch - M12 (Brad Harrison 4-pin micro connector)

Modification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Clogging Indicators section.)

Page 38: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F38

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 04 08 13 16

Weight (lbs.) 49.2 56.1 72.5 107.3

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions HF3P-04/08/13/16

6.42163

6.30160

c x d DP4 Places

b

a

6.42163

1/2"-20UNF x [0.67]

174 Places 60

2.36

5.23133

4.53115

Drain PortG 1/2"

[4.53] 115Clearance requiredfor element removal

[16.81] 427Clearance required forelementremoval

Flange

Drain PortG 1/2"

∆P Clogging IndicatorPort G 1/2"

56922.40

112

HF3P-16

HEX

1305.12

1.42

36

1525.98

4.41

6.30160

InletOutlet

∆P Clogging IndicatorPort G 1/2"

1.4236

2.05

0.2452

18.98

482.1 HF3P-13

6

[10.00] HF3P-04 254

[74.00]HF3P-08 349

HEX

5.12130

a b c d

1-1/2” Code 61

(1.406) 35.71

(2.750) 69.85

1/2-13UNC-2B (0.87) 22

2” Code 62

(1.750) 44.45

(3.812) 96.80

3/4-10UNC-2B (0.98) 25

HF3P-16

Page 39: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F39

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Autospec HF3 Depth 1.11.08DXXBN (Low Collapse)Size 3 µm 6 µm 12 µm 25 µm

1.11.04DXXBN 0.590 0.500 0.266 0.1531.11.08DXXBN 0.289 0.241 0.135 0.0761.11.13DXXBN 0.175 0.146 0.082 0.0461.11.16DXXBN 0.132 0.110 0.062 0.035

Autospec HF3 Depth 1.11.08DXXBH (High Collapse)Size 3 µm 6 µm 10 µm 17 µm

1.11.04DXXBH 0.937 0.660 0.401 0.2101.11.08DXXBH 0.460 0.321 0.195 0.1021.11.13DXXBH 0.274 0.193 0.117 0.6151.11.16DXXBH 0.206 0.145 0.089 0.046

All Element K Factors in psi / gpm.

Page 40: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F40

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Automotive Construction Industrial

Pulp & Paper Railways

PowerGeneration

Steel / HeavyIndustry

Features• Meets HF4 automotive standard• Non-welded housing design reduces stress concentrations and

prevents fatigue failure.• Inlet/Outlet port options include SAE straight thread O-ring boss,

SAE flange code 62 and code 61 (optional) BSPP and subplate mounting to allow easy installation without costly adapters.

• O-ring seals are used to provide positive, reliable sealing. A choice of O-ring materials (nitrile rubber or fluorocarbon elastomer) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.

• The element filter housing is permanently mounted above the filter head for easy top access and minimal clearance to remove elements for replacement.

• Clogging indicators are actuated by differential pressure and have no external dynamic seal. High reliability is achieved and magnetic indicator actuation eliminates a potential leak point.

• A poppet type bypass valve located in filter head base is mounted between the inlet and outlet port to provide positive sealing during normal operation and fast response during cold starts and flow surges.

• Fatigue pressure rating equals maximum allowable working pressure rating.

HF4P SeriesInline Filters5000 psi • up to 120 gpm

A

B

Technical SpecificationsMounting Method 4 mounting holesPort Connection SAE-24, 1 1/2” BSPP, 1 1/2” SAE

Flange Code 61, 1 1/2” SAE Flange Code 62, Manifold Mount

Flow Direction Inlet: Side Outlet: Side(opposite each other)

Construction MaterialsHead, CapHousing

Ductile ironSteel

Flow Capacity9”18”27”

50 gpm (189 lpm)100 gpm (378 lpm)120 gpm (454 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

5000 psi (345 bar)5000 psi (345 bar) @ 1 million cycles15,000 psi (1040 bar)

Element Collapse Pressure RatingBHBN

3045 psid (210 bar)145 psid (10 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) -10% (optional on non-bypass filters)

Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)Non Bypass Available

Page 41: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F41

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeHF4P BN 09 G 3 D 1 . 1 / 12 V B6 L115

Filter Type HF4P = Inline pressure filter

Element Media BH = Betamicon® (High Collapse) BN = Betamicron® (Low Collapse) W = Wire Mesh

Element Length 09 = 9 inches 18 = 18 inches 27 = 27 inches

Type of Connection P = Manifold Mount G = Threaded In-Line F = Flanged

Filtration Rating (microns) 3, 5, 10, 20 = BH, BN 25, 74, 149 = W

Type of Clogging Indicator A, BM, C, D, J, J4 (others available upon request)

Type Code 1

Modification Number (the latest version is always supplied)

Port Configuration (omit) = Manifold mount (use when “P” connection type is selected) 0 = 1 1/2” BSPP Straight Threads 12 = SAE-24 straight thread O-ring boss 16 = 1 1/2” SAE 4 bolt flange code 61 or 62

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Bypass Valve (omit) = Non-bypass – Critical applications (high collapse element required) B3 = 43 psid (3 bar) B6 = 87 psid (6 bar) Standard setting for pressure filters

Supplementary Details W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Thermal lockout on indicator at 100°F (C, D, J, and J4 indicators only) Code 61 = 4 Bolt Code 61 (changes MAWP from 5000 PSI to 3000 PSI) cRUus = Electrical Indicator with underwriter’s recognition

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Replacement Element Model Code5 . 03 . 09 D 03 BN / V

Length (nominal inches) 09, 18, 27Filtration Rating (micron) 3, 5, 10, 20 = BN, BH 25, 74, 149, = WElement Media BN, BH, WSeals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Clogging Indicator Model CodeVD 5 D . X / V .

Indicator Prefix VD = G 1/2 6000 psi

Trip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 15 psid (1 bar) & 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT J = Electric switch (Brad Harrison 5-pin mini connector) J4 = Electric switch - M12

(Brad Harrison 4-pin micro connector)

Modification Number

Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Light Voltage (D type indicators only) L24 = 24V L48 = 48V L110 = 110V L220 = 220V

Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F

Underwriters Approval (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicators with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 42: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F42

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 09 18 27

Weight (lbs.) 69.9 98.4 132.8

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

38.1

a

b

HF4P-09

[12.00]305

HF4P-18 [21.00]533

HF4P-27 [30.00]762

Clearance requiredfor element removal

c x d DPSAE Flange

INLET1-1/2" Nominal Port2 Places

HF4P-09[16.33]

415HF4P-18[25.62]

651HF4P-27[35.00]

889

0.8822.4

P Cloggingindicator portG 1/2"

Vent PlugSAE-4(7/16-20UNF)

1596.25

1.3835

2.7569.9

Drain PlugSAE 8(3/4"-16UNF)

133.45.25

5.75146

4.50

1275.00

114.3

14Mounting

holes Through4 Places

Dimensions HF4P Inline

Flange Details a b c d

Code 61

(1.406) 35.7

(2.750) 69.8

1/2-13UNC (1.06) 27

Code 62

(1.437) 36.50

(3.125) 79.38

5/8-11UNC (1.38) 35

Page 43: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F43

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 09 18 27

Weight (lbs.) 71.7 100.2 134.6

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Drain PlugSAE 8(3/4"-16UNF)

Vent PlugSAE 4(7/16"-20UNF)

15 159

22 0.88

0.586.25

1.3835

2.7569.9

OUTLET[1.25]

32

INLET[1.25]

32127 5.00

2.0050.8

Mounting

4 Places

14

0.56

2.2557.2

holes Through

114.3 4.50

0.8120.6

∆P CloggingIndicator PortG 1/2"

133.45.25

5.75146 HF4P-09

[12.00]305

HF4P-18 [21.00]533

HF4P-27 [30.00]762

Clearance requiredfor element removal

HF4P-09[16.30]

414HF4P-18[25.59]

650HF4P-27[34.98]

888

Dimensions HF4P Manifold

Page 44: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F44

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Autospec HF4 Wire Mesh 5.03.XXDXXWSize 25, 74, 149, µm

5.03.09DXXW 0.0075.03.18DXXW 0.0045.03.27DXXW 0.002

Autospec HF4 Depth 5.03.XXDXXBN (Low Collapse)Size 3 µm 5 µm 10 µm 20 µm

5.03.09DXXBN 0.168 0.141 0.079 0.0445.03.18DXXBN 0.080 0.067 0.038 0.0215.03.27DXXBN 0.052 0.043 0.024 0.014

Autospec HF4 Depth 5.03.XXDXXBH (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

5.03.09DXXBH 0.207 0.146 0.089 0.0475.03.18DXXBH 0.097 0.068 0.041 0.0225.03.27DXXBH 0.063 0.044 0.027 0.014

All Element K Factors in psi / gpm.

Page 45: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F45

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Notes

Page 46: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F46

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Gearboxes

Industrial CommercialMunicipal

Features• Because of their efficient design and construction, MFM filters

are considered a cost effective solution for new equipment, or as a replacement for filters already specified on existing equipment.

• The MFM filter is available in 4 sizes comprised of four different bowl and element lengths. The models 35, 55, 75, and 95, provide maximum flow rates of 10, 18, 20, and 25 GPM respectively.

• A quick-response bypass valve located in filter head protects against high differential pressures caused by cold startups, flow surges and pressure spikes.

• The high bypass pressure setting (100 psid) minimizes the possibility of contamination due to premature bypassing.

• Filter materials are compatible with all mineral, lubricating oils, and commonly used fire retardant fluids per ISO 2943.

• Fatigue pressure rating equals maximum allowable working pressure rating.

MFM SeriesInline Filters4060 PSI • up to 25 GPM

A

B

Technical SpecificationsMounting Method 4 mounting holes - filter headPort Connection SAE-12, 3/4” BSPPFlow Direction Inlet: Side

(opposite each other)Outlet: Side

Construction MaterialsHeadBowl

Ductile ironSteel

Flow Capacity35557595

10 gpm (35 lpm)18 gpm (68 lpm)20 gpm (76 lpm)25 gpm (95 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue Pressure

Burst Pressure

4060 psi (280 bar)4060 psi (280 bar) @ 1 million cycles4641 psi (320 bar) @ 100,000 cycles13,920 psi (960 bar)

Element Collapse Pressure RatingON 290 psid (20 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 72 psid (5 bar) -10%Bypass Valve Cracking Pressure∆P = 50.75 psid (3.5 bar) +10% (optional)∆P = 100 psid (7 bar) +10% (standard)

Page 47: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F47

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeMFM ON 35 O I 10 C 4 . 0 / V B7 .

Filter Type MFM = In-Line High Pressure Filter

Element Media ON = Optimicron® (Low Collapse)

Size 35 = 10 gpm 55 = 18 gpm 75 = 20 gpm 95 = 25 gpm

Operating Pressure O = 4000 psi (280 bar)

Type of Connection I = 3/4” Threaded SAE 12 (1-1/16-12UN-2B)) H = 3/4” Threaded G 3/4 (BSPP) (Other connections available on request)

Filtration Rating (microns) 1, 3, 5, 10, 15, 20 = ON

Type of Clogging Indicator A, B, BM, C, D (Others available upon request)

Type Number 4 = Indicator port on top of head - 4 mounting holes (standard) 3 = Indicator port on side of head - 3 mounting holes

Type Modification Number (latest version always supplied)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Bypass Valve B3.5 = 50.75 psid (3.5 bar) - Optional B7 = 101.5 psid (7 bar) - Standard

Supplementary Details W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) LED = 2 LEDs up to a voltage of 24 Volt T100 = Indicator Thermal Lockout, 100°F (C and D indicators only) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with underwriter’s recognition

Replacement Element Model Code 0035 D 010 ON / V Size 0035, 0055, 0075, 0095

Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON

Element Media ON = Optimicron®

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Supplementary Details SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 5 C . X / V .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard)

Type of Indicator A = no indicator, plugged port B = Pop-up indicator (auto reset)

- top mount only BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 48: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F48

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 35 55 75 95

Weight (lbs.) 8.2 9.3 10.4 11.3

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

3.5490

1.3835

Mounting Holes3/8-16 UNC-2B x 12 DP4 Places

2.17 55

1.5740

1.0125.7

∆ P Clogging Indicator PortG 1/2HEX 27

INLET

OUTLET

for Element RemovalClearance Required 74[2.91]

86

3.00

3.39

76.2

HEX 0.9424

Size 95 297

259

60.24

3.62

Size 75 [11.77]

92

10.20

[6.30]Size 35 160

[8.11]Size 55 206

3.5490

Dimensions MFM 4.X Version (Standard)

Page 49: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F49

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 35 55 75 95

Weight (lbs.) 8.2 9.3 10.4 11.3

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

1.3835

3.5490

74

Clearance Requiredfor Element Removal

[2.91]

10.20259

[11.77]Size 95 297

903.54

[6.30] Size 35 160

[8.11] Size 55 206

Size 75

3.6292

0.9424

76.2

HEX

3.00

3.3986

∆P Clogging Indicator Port G1/2HEX 27

INLETOUTLET

1.26

3/8-16UNC-2B

55°

3 Places

32

Mounting Holes

56 2.20

23.50.93

1.7745

Dimensions MFM 3.X Version

Page 50: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F50

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Q in gpm

0.0

5.0

10.0

15.0

20.0

25.0

0 3 5 8 11 13 16 18 21 24 260.00

0.34

0.69

1.03

1.38

1.720 10 20 30 40 50 60 70 80 90 100

Q in l/min

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Optimicron …D…ON (Pressure Elements)Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

0035 D XXX ON 2.755 1.169 0.938 0.752 0.549 0.4080055 D XXX ON 1.427 0.675 0.543 0.434 0.284 0.2110075 D XXX ON 0.916 0.461 0.37 0.296 0.183 0.1360095 D XXX ON 0.724 0.37 0.296 0.238 0.144 0.105

All Element K Factors in psi / gpm.

Page 51: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F51

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Notes

Page 52: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F52

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Gearboxes

Industrial CommercialMunicipal

PowerGeneration

Features• The HFM filter is available in two sizes comprised of two different

bowl and element lengths. The models 75 and 95 provide maximum flow rates of 29 and 37 GPM respectively.

• A quick-response by-pass valve located in the filter head, protects against high differential pressures caused by cold start-ups, flow surges and pressure spikes.

• The high bypass pressure setting (100 psid) minimizes the possibility of contamination due to premature bypassing.

• Filter materials are compatible with all mineral, lubricating oils, and commonly used fire retardant fluids per ISO 2943.

• Fatigue pressure rating equals maximum allowable working pressure rating.

• Wide variety of indicators available with standard setting of 72 psid (5 bar).

HFM SeriesInline Filters5800 psi • up to 37 gpm

A

B

Technical SpecificationsMounting Method 3 or 4 mounting holes - filter headPort Connection SAE 16, 1” BSPPFlow Direction Inlet: Side

(opposite each other)Outlet: Side

Construction MaterialsHeadBowl

Ductile ironSteel

Flow Capacity7595

29 gpm (110 lpm)37 gpm (140 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

5800 psi (400 bar)Contact HYDAC office13,920 psi (960 bar)

Element Collapse Pressure RatingON 290 psid (20 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications below 14˚F (-10˚C)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 72 psid (5 bar) -10% (standard)

Bypass Valve Cracking Pressure∆P = 101.5 psid (7 bar) +10% (standard)

Page 53: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F53

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model Code HFM ON 95 S K 10 A 1 . 0 / V B7 Filter Type HFM = In-Line High Pressure Filter

Element Media ON = Optimicron® (Low Collapse)

Size 75 = 29 gpm 95 = 37 gpm

Operating Pressure S = 5800 psi (400 bar)

Type of Connection J = 1” threaded (1” BSPP) K = 1” threaded (1 5/16” threaded-12UN)=SAE 16

Filtration Rating (microns) 1, 3, 5, 10, 15, 20 = ON

Type of Clogging Indicator A, B, BM, C, D (Others available upon request)

Type Number 1

Type Modification Number (latest version always supplied)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Bypass Valve B3.5 = 50.75 psid (3.5 bar) (optional) B7 = 101.5 psid (7 bar) (standard)

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) LED = 2 LEDs up to a voltage of 24 Volt T100 = Thermal lockout on indicator at 100°F (C and D indicators only) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with underwriter’s recognition

Replacement Element Model Code 0095 D 010 ON / V Size 0075, 0095

Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = BN4HC

Element Media ON = Optimicron®

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Supplementary Details SO263 = (same as above) SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 5 B . X / V .

Indicator Prefix VD = G 1/2 6000 psi

Trip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 15 psid (1 bar) & 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT

Modification Number

Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Light Voltage (D type indicators only) L24 = 24V L110 = 110V

Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F

Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 54: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F54

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 75 95

Weight (lbs.) 12.4 13.5

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions HFM 75/95

1.3835

3.8698

SAE mounting Pattern BSPP Mounting Pattern

75Clearance requiredfor element removal

[2.95]

∆P CloggingIndicator PortG 1/2HEX 27

4.21 107

HFM 95 311

10.67271HFM 75

[12.24]

0.24

6 Inlet

3.0076.2

HEX 0.9424

OUTLET

4 Places

[0.33]5/16-24UNF-2B x 8.5 DPMounting holes

INLET

1.1028

104 4.09

321.26

51

2.01

2.2056

OUTLET

4 Places

3 PlacesMounting holesM8 x 1.25 x 12 DP [0.47]

[0.43]M6 x 1.0 x 11 DPMounting Holes

INLET

2.20

56 56

2.20

190.75

32 1.26

0.35

9

Page 55: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F55

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Q in gpm

Q in l/min

0.0

1.4

2.9

4.3

5.8

7.2

8.7

10.1

0 5.3 10.6 15.8 21.1 26.4 31.7 37.00.0

0.1

0.2

0.3

0.4

0.5

0.6

0.70 20 40 60 80 100 120 140

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Optimicron …D…ON (Pressure Elements)Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

0075 D XXX ON 0.916 0.461 0.37 0.296 0.183 0.1360095 D XXX ON 0.724 0.37 0.296 0.238 0.144 0.105

All Element K Factors in psi / gpm.

Page 56: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F56

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Industrial

Railways PowerGeneration

Steel / HeavyIndustry

Features• The FMND filter consists of a ductile iron filter head with built-in

changeover valve and three different lengths of screw-in filter bowls.

• The FMND filter can be supplied with or without bypass valve, (located in head assembly) but includes vent and drain screws, and also a connection for a differential pressure clogging indicator.

• Pressure equalization requirement is achieved by raising the changeover lever prior to switching it to the relevant filter side.

• Fatigue pressure rating = maximum allowable working pressure rating.

• Germanischer Lloyd (GL) approved• This filter meets the requirements of DIN 24550 as follows:

- Filter size 0160 with G 1-1/4” port selection - Filter size 0250 with G 1-1/2” port selection - Filter size 0400 with SAE-DN 38 1-1/2” Flange Port Selection

FMND SeriesInline Duplex Filters3000 psi • up to 100 gpm

VA

OUTLET

INLET

Technical SpecificationsMounting Method 4 Mounting holesPort Connections Inlet / Outlet

1-1/4” Threaded – SAE 20, 1-1/4” BSPP1-1/2” Threaded – SAE 24, 1-1/2” BSPP1-1/2” Flange-SAE-DN 38

Flow Direction Inlet: Side Outlet: Opposite SideConstruction MaterialsHeadBowl

Ductile ironSteel

Flow Capacity160250400

42 gpm (160 lpm)66 gpm (250 lpm)100 gpm (400 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

3000 psi (207 bar)3000 psi (210 bar) @ 1 million cycles10,650 psi (735 bar)

Element Collapse Pressure RatingBH4HCBN4HC, W/HC

3045 psid (210 bar)290 psid (20 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid CompatibilityCompatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 36.25 psid (2.5 bar) -10% (optional) ∆P = 50.75 psid (3.5 bar) +10% (optional)∆P = 72 psid (5 bar) -10% (standard) ∆P = 116 psid (8 bar) -10% (optional) [Used with non-bypass]

Bypass Valve Cracking Pressure∆P = 102 psid (7 bar) +10%

Page 57: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F57

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeFMND BN/HC 250 L D F 10 C 1 . X / 12 - V - .

Filter Type FMND = Inline Duplex Filter

Element Media BH/HC = Betamicron® (High Collapse) BN/HC = Betamicron® (Low Collapse) W/HC = Wire Mesh

Size 160, 250, 400

Operating Pressure L = 3000 psi (210 bar)

Type of Changeover D = segment valve

Type and Size of Port E = 1-1/4” Threaded – SAE 20, 1-1/4” BSPP F = 1-1/2” Threaded – SAE 24, 1-1/2” BSPP K = 1-1/2” Flange-SAE-DN 38

Filtration Rating (micron) 3, 6, 10, 25 = BH/HC 3, 6, 10, 25 = BN/HC 25, 50, 100, 200 = W/HC

Type of ∆P Clogging Indicator A, B, BM, C, D (Others available upon request)

Type Code 1

Modification Number (the latest version is always supplied)

Port Configuration (omit) = SAE DN Flange 0 = BSPP Threaded 12 = SAE Straight Threaded Seals (omit) = Nitrile rubber (NBR) V = Fluorocarbon elastomer (FKM) (standard)

Bypass Valve (omit) = no bypass (optional) B3.5 = 50.75 psid (3.5 bar) (optional) B7 = 101.5 psid (7 bar) (standard)

Supplementary Details L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) RL = Flow Path reversed - Right inlet/Left outlet SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids SO155H = Modification of BH4HC (High Collapse) Element For Phosphate Esters cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Replacement Element Model Code0250 DN 010 BN4HC / V .

Size 0160, 0250, 0400

Type DN

Filtration Rating (micron) 3, 6, 10, 25 = BN4HC 25, 50, 100, 200 = W/HC

Element Media BN4HC, W/HC

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Supplementary Details SFREE = (same as above) SO263 = (same as above) SO155H = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVM 8 C . X / V .

Indicator Prefix VM = G 1/2 3000 psi

Trip Pressure 2 = 29 psid (2 bar) (optional) 5 = 72 psid (5 bar) 8 = 116 psid (8 bar)

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT

Modification Number

Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Light Voltage (D type indicators only) L24 = 24V L110 = 110V

Thermal Lockout (VM types C, D, J, and J4 only) T100 = Lockout below 100°F

Underwriters Recognition (VM types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

(For additional details and options, see Section G - Clogging Indicators.)

Page 58: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F58

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 160 250 400

Weight (lbs.) 52.7 59.8 71.0

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

DimensionsFMND 160/250/400

1305.12

4.17106

FMND 160:11.95303.5

FMND 250:[15.49]393.5

FMND 400:[21.39]543.5

11.02280 LDK[11.10]282 LDE/LDF

1.9750

4.13105

TELTUOTELNI

2.4462

4.9

124.5

4.49114

8.27210

See chart4 Places

2.0552

0.9825

2.2657.5

2.6868

7.58192.5

Dirty sideVent portSW5G 1/8"

Dirty sideVent portSW5G 1/8"

∆P CloggingindicatorPortG 1/2"

Dirty side drain portdrain plug (included)SW8G 3/8"2 Places

[1.26]32HEX

-LDE1 5/8"-12UN-2BSAE-20OR-LDF1 7/8"-12UN-2BSAE-24OR-LDK1 1/2" SAE DN 38FlangeINLET AND OUTLET

2.7569.9

1.4135.7

M12 X 1.75 X 0.75

19 DP4 Places

[3.35]85

Clearance requiredfor element removal

FlangeLDK Version

Model Mounting HoleFMND160-400LDE M12X1.75 x 19mm DeepFMND160-400LDE/12 3/8-24UNF x 14mm DeepFMND160-400LDF M12X1.75 x 19mm DeepFMND160-400LDF/12 3/8-24UNF x 14mm DeepFMND160-400LDK M12X1.75 x 19mm Deep

Before changing the element, relieve pressure in the filter housing.

Page 59: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F59

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Betamicron ...DN…BN/HC Elements (Low Collapse)Size 3µm 6 µm 10 µm 25 µm

0160 DN XXX BN4HC 0.434 0.280 0.187 0.1430250 DN XXX BN4HC 0.280 0.176 0.115 0.0990400 DN XXX BN4HC 0.176 0.110 0.071 0.055

Wire Mesh ...DN…W/HC ElementsSize 25 µm 50 µm 100 µm 200 µm

0160 DN XXX W/HC 0.009 0.009 0.009 0.0090250 DN XXX W/HC 0.006 0.006 0.006 0.0060400 DN XXX W/HC 0.004 0.004 0.004 0.004

Betamicron ...DN…BH/HC Elements (High Collapse)Size 3 µm 6 µm 10 µm 25 µm

0160 DN XXX BH4HC 0.439 0.280 0.209 0.1370250 DN XXX BH4HC 0.296 0.187 0.154 0.1040400 DN XXX BH4HC 0.187 0.115 0.093 0.060

All Element K Factors in psi / gpm.

FMND 160/250/400 LDK

FMND 160/250/400 LDF

1-7/8"-12UN-2BSAE-24 Port

OUTLET & INLET

FMND 160/250/400 LDK

INLET & OUTLETDN38 3000 PSI Flange SAE (1 1/2" Flanged)

[2.75]69.9

[1.41]35.7

[0.75]M12X1.75X19 DP

FMND 160/250/400 LDE

1-5/8"-12UN-2BSAE-20 PortINLET & OUTLET

Page 60: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F60

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Automotive Industrial Pulp & Paper

Railways

PowerGeneration

Steel / HeavyIndustry

Features• The DFDK Filters have a filter head of ductile iron and a screw-in

bowl of cold-formed steel.• The filter housings are designed to withstand pressure surges as

well as high static pressure loads.• The screw-in bowl or lid, allows the filter element to be easily

removed for replacement or cleaning.• A visual (pop-up), electrical, electrical/visual (lamp), or other

electronic differential types of clogging indicators are available to suit each application.

• DFDK filters are available only with high collapse pressure elements since no bypass is provided.

• DFDK sizes 330 and above can be ordered with a T Ball Valve which can operate in mid position with both elements fully open and online in parallel.

DFDK SeriesInline Duplex Filters4568 psi • up to 90 gpm

A

B

A

B

Technical SpecificationsMounting Method 4 mounting holesPort Connection60/110160/240/280330/660/1320

SAE-12SAE-242” SAE-DN 50 Flange

Flow Direction 60 - 280 330 - 1320InletOutlet

TopSide

TopBack

Construction MaterialsHeadBowlHousing (1320)Lid/Cap (1320)

Ductile ironSteelSteelDuctile iron

Flow Capacity60/110160/240/280330/660/1320

13 gpm (50 lpm)35 gpm (132 lpm)90 gpm (340 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

4568 psi (315 bar)Contact HYDAC Office> 18,270 psi (1260 bar)

Element Collapse Pressure RatingBH4HC, V 3045 psid (210 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 116 psid (8 bar) -10% (standard)Non-bypass Only

DFDK…QL “L” Ball Valve

DFDK…QT “T” Ball Valve (sizes 330 or larger)

Page 61: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F61

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeDFDK BH/HC 60 Q L C 3 A 1 . 2 - .

Filter Type DFDK = Duplex Pressure Filter with Ball Valve Selector

Element Media BH/HC = Betamicron® (High Collapse) V = Metal Fiber

Size 60, 110, 160, 240, 280, 330, 660, 1320 (larger sizes available - contact HYDAC)

Pressure Range K = 2320 psi (160 bar) (sizes 1320 with type code 3 only - larger sizes upon request) Q = 4568 psi (315 bar) (sizes 30 - 1320 with type code 1 or 2 only)

Valve L = ball change-over valve in “L” configuration (standard) T = ball change-over valve in “T” configuration

(full simultaneous flow through both sides - sizes 330 and larger)

Connection B = 1/2” SAE 8 (size 30 only) L = 2” SAE DN 50 (sizes 330 - 1320 only) C = 3/4” SAE 12 (sizes 60/110 only) M = 2 1/2” SAE DN 65 (sizes 1320 only) - 3.0 only F = 1 1/2” SAE 24 (sizes 160 - 280 only)

Filtration Rating (micron) 3, 5, 10, 20 = BH/HC 3, 5, 10, 20 = V

Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)

Type Code 1 = One Piece Bowl (sizes 60 - 660 only) 2 = Two Piece Bowl (size 660 to 1320 only) 3 = Upside down mounting - Element top access (size 1320 only - larger sizes upon request)

Modification Number (latest version always supplied)

Port Configuration omit = 2” SAE DN 50 Flange Ports (sizes 330-1320 only) 12 = SAE Straight thread O-ring Boss Ports (sizes 60-280 only)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene (EPR)

Supplementary Details L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids T100 = Thermal lockout on indicator at 100°F (C, D, J, and J4 indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Replacement Element Model Code0060 D 003 BH4HC / V

Size 0060, 0110, 0160, 0240, 0280, 0330, 0660, 1320

Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 3, 5, 10, 20 = V

Element Media BH4HC, V

Seals (omit) = Nitrile rubber (NBR) (standard)

V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) SFREE = (same as above)

W = Modification of “V” elements for use with oil water emulsions (HFA) and water polymer solutions (HFC)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 8 B . X / .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 8 = 116 psid (8 bar)Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 62: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F62

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 60 110 160 240 280

Weight (lbs.) 33.1 37.5 72.8 79.4 99.3

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFDK 60 / 110 / 160 / 240 / 280

220.3

h7 MAX

b13

h8Clearance Requiredfor Element Removal

d4 x t1

G 1/2" Drain

h1

b1

h3

b12 SQ1

b14

h9 b5

b2

h6

b6

h2

h5

0.24

6

HEX 1

HEX 2drain

OUTLETd2

b7

d3

h4

INLETd1

∆P CloggingIndicator PortG 1/2"

b4

b9

b11

b8

b10 Vent Plug G1/8Clean Side

Vent Plug G1/8Dirty Side

Page 63: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F63

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

DFDK 60 110 160 240 280

b1 [5.43] 138 [5.43] 138 [7.48] 190 [7.48] 190 [7.48] 190

b2 [6.69] 170 [6.69] 170 [8.27] 210 [8.27] 210 [8.27] 210

b4 [3.62] 92 [3.62] 92 [5.04] 128 [5.04] 128 [5.04] 128

b5 [1.77] 45 [1.77] 45 [2.07] 52.5 [2.07] 52.5 [2.07] 52.5

b6 [4.78] 121.5 [4.78] 121.5 [6.20] 157.5 [6.20] 157.5 [6.20] 157.5

b7 [2.13] 54 [2.13] 54 [2.97] 75.5 [2.97] 75.5 [2.97] 75.5

b8 [1.02] 26 [1.02] 26 [1.40] 35.5 [1.40] 35.5 [1.40] 35.5

b9 [3.43] 87 [3.43] 87 [4.13] 105 [4.13] 105 [4.13] 105

b10 [1.91] 48.5 [1.91] 48.5 [2.07] 52.5 [2.07] 52.5 [2.07] 52.5

b11 [2.13] 54 [2.13] 54 [2.97] 75.5 [2.97] 75.5 [2.97] 75.5

b12 [0.63] 16 [0.63] 16 [0.39] 10 [0.39] 10 [0.39] 10

b13 (≈) [5.91] 150 [5.91] 150 [7.60] 193 [7.60] 193 [7.60] 193

b14 (≈) [7.13] 181 [7.13] 181 [8.70] 221 [8.70] 221 [8.70] 221

d1*1-1/16-12UN-2B

SAE-121-7/8-12UN-2B

SAE-24d2*

d3 [2.69] 68.2 [2.69] 68.2 [3.75] 95.2 [3.75] 95.2 [3.75] 95.2

d4 1/4-28UNF-2B 3/8-24UNF-2B

h1 [3.07] 78 [3.07] 78 [3.78] 96 [3.78] 96 [3.78] 96

h2 [4.61] 117 [4.61] 117 [6.38] 162 [6.38] 162 [6.38] 162

h3 [0.77] 19.5 [0.77] 19.5 [1.30] 33 [1.30] 33 [1.30] 33

h4 [2.54] 64.5 [2.54] 64.5 [4.17] 106 [4.17] 106 [4.17] 106

h5 [2.99] 76 [2.99] 76 [3.94] 100 [3.94] 100 [3.94] 100

h6 [8.07] 205 [10.89] 276.5 [11.20] 284.5 [13.60] 345.5 [20.69] 525.5

h7 (≈) [8.07] 205 [8.07] 205 [9.65] 245 [9.65] 245 [9.65] 245

h8 [2.95] 75 [2.95] 75 [3.35] 85 [3.35] 85 [3.35] 85

h9 [0.20] 5 [0.20] 5 [0.20] 5 [0.20] 5 [0.20] 5

t1 [0.28] 7 [0.28] 7 [0.43] 11 [0.43] 11 [0.43] 11

HEX1 [1.06] 27 [1.06] 27 [1.26] 32 [1.26] 32 [1.26] 32

HEX2 [0.39] 10 [0.39] 10 [0.39] 10 [0.39] 10 [0.39] 10

SQ1 [0.47] 12 [0.47] 12 [0.55] 14 [0.55] 14 [0.55] 14

Dimensions shown are [inches] millimeters for general information and overall envelope size only.

Page 64: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F64

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 330 660

Weight (lbs.) 213.9 249

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFDK 330 / 660…1.2

1.7544.5

3.8196.8

3/4-10UNC-2B x[0.98] Min. 25 Full Thread4 PL's

8.98228

Approx.

0.6215.7

10.63270

Approx.

INLET / OUTLET Flange

5.13

1525.98

130.2

3.2783

[3.74] 95Clearance required for element removal

PressureEqualizationValve

150

175

325

60.52.38

5.91

12.8

6.89

0.6215.7

Approx.

Indexing plungerfor locking the lever (optional)

Lifting holes [0.67] 1/2-20UNF-2B x 17 DP

INLETSAE 2"(DN50)6000 PSI

∆P Clogging

Clean SideVent Plug G1/8

Dirty SideVent Plug G1/8

indicator portG1/2"

Vent PlugG1/8"

80.31

2007.87

0.24

6

Drain PortG 1/2"

Mountingring size660 only

5.39137

3.8698

OUTLETSAE 2" (DN50) 6000 PSI

295 4.69119 51

209 8.23

823.23

0.59

1295.08 0.79

20

HEX

11.61

1706.69

0.671/2-20UNF-2B X 17 DP

4 PLS

1.42

36

9.65245

SIZE 330[14.51]368.5

SIZE 660[21.18]

538

Page 65: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F65

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 660 1320

Weight (lbs.) 262.5 335.1

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFDK 660 / 1320…2.2

8.98228

Approx.

0.6215.7

10.63270

Approx.

1.7544.5

3.8196.8

3/4-10UNC-2B x[0.98] Min. 25 Full Thread

5.2

SIZE 660[20.91]

531SIZE 1320

[33.58]853

SIZE 660[13.78]

350SIZE 1320

[26.38]670

4.41112

132

1525.98

3.2783

Pressureequalizationvalve

5.39137

3.8698

OUTLETSAE 2" (DN50) 6000 PSI

7.87200

0.24

6

INLET / OUTLET Flange

Drain portG 1/2"

Lifting Holes [0.67]

1/2-20UNF-2B x 17 DP

1505.91

325

6.89

175

12.8

2.38

60.5

0.6215.7

Approx.

INLETSAE 2" (DN50) 6000 PSI

Vent plugG1/8"

Indexingplunger for locking lever(Optional)

∆P CloggingIndicator Port G 1/2"

6.69170

2098.23

0.795.08

1.42 HEX

4 PLS1/2-20UNF-2B X 17 DP

0.67

295

3.23

82

11.61

1194.69

36

20

15 0.59

129

9.65245

Clean SideVent Plug G1/8

Dirty SideVent Plug G1/8

Page 66: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F66

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

00

5

10

15

20

25

30

35

0

0.5

1.0

1.5

2.0

10 20 30

0 20 40 60 80 100

Q (gpm)

DFDK 60 / 110 Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

10

20

30

40

50

0

1.5

1.0

0.5

2.0

2.5

3.0

10 20 30 40 50

0 30 60 90 120 150 180

Q (gpm)

DFDK 160 / 240 / 280 Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

5

10

15

25

20

30

0

0.5

1.0

1.5

2.0

4020 60 80 100 120 140 160

0 100 200 300 400 500 600

Q (gpm)

DFDK 330 / 660 / 1320 QLL Housing “L” Ball Valve

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

5

35

30

25

10

15

20

0

0.50

1.5

1.0

2.0

50 100 150 200 250

0 200 300100 400 500 600 700 800 900

Q (gpm)

DFDK 330 / 660 / 1320 QTL Housing “T” Ball Valve

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Page 67: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F67

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.1180160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012

Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.3070160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022

All Element K Factors in psi / gpm.

Notes

Page 68: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F68

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Automotive Industrial Pulp & Paper

Shipbuilding

PowerGeneration

Steel / HeavyIndustry

Features• The HFDK4P pressure duplex filter meets HF4 automotive

specification element requirements.• The HFDK4P filters have a filter head and lid of ductile iron

and a cold formed steel housing to meet high fatigue pressure requirements.

• The filter housings are designed to withstand pressure surges as well as high static pressure loads.

• The screw-in lids allow top access for the filter element to be easily removed for replacement.

• Visual (pop-up), electrical, electrical/visual (lamp), or electronic differential type clogging indicators are available.

• HFDK4P filters are available only with high collapse pressure elements with no bypass provided.

HFDK4P SeriesInline Duplex Filters4568 psi • up to 90 gpm

A

B

Technical SpecificationsMounting Method 4 mounting holesPort Connection 2” SAE Flange Code 62Flow Direction Inlet: Bottom Outlet: Left SideConstruction MaterialsHead, LidHousing

Ductile ironSteel

Flow Capacity9”18”27”

50 gpm (189 lpm)75 gpm (284 lpm)90 gpm (340 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

4568 psi (315 bar)4500 psi (315 bar)Contact HYDAC Office

Element Collapse Pressure RatingBH 3045 psid (210 bar)

Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)

Fluid CompatibilityCompatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 116 psid (8 bar) -10% (standard)∆P = 72 psid (5 bar) -10% (optional)

Page 69: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F69

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model Code HFDK4P BH 27 F 5 C 1 . 2 / 16 A5 V Filter Type HFDK4P = Inline duplex pressure filter

Element Media BH = Betamicon® (High Collapse)

Element Length 09 = 9 inches 18 = 18 inches 27 = 27 inches

Type of Connection F = Flanged

Filtration Rating (micron) 3, 5, 10, 20 = BH

Type of Clogging Indicator A, B/BM, C, D

Type Code 1

Modification Number (the latest version is always supplied)

Port Configuration 16 = 2” SAE 4 bolt flange (code 62)

Indicator Trip Pressure (omit) = 116 psid (8 Bar) (standard) A5 = 72 psid (5 Bar)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Supplementary Details SO155H = Modification of BH elements for phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100ºF (C and D indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Replacement Element Model Code 5 . 03 . 27 D 05 BH /-V Length (nominal inches) 09, 18, 27Filtration Rating (micron) 3, 5, 10, 20 = BHElement Media BHSeals (omit) = Nitrile rubber (NBR) (standard)

V = Fluorocarbon elastomer (FKM) Supplementary Details SFREE = (same as above)

Clogging Indicator Model CodeVD 8 C . X / V .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 5 = 72 psid (5 bar) (optional) 8 = 116 psid (8 bar) (standard)

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and led light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) V = Fluorocarbon elastomer (FKM) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 70: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F70

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 09 18 27

Weight (lbs.) 233.7 270.5 306.4

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

1.7544.5

3.8196.8 SAE Flange

2" SAE CODE 62

3/4"-10UNC-2Bx 25DP

10.65270.5

(7/16-20 UNF)SAE-4Vent Plug

Drain Plug Dirty sideSAE-8(3/4-16UNF)

178

3.27

45

0.88 22.4

1.77

18 696.1

457.8

27 934.6

[27.41]

[36.79]

18.02

83

7.01

5.25

12.80325

133.4

HFDK4P-09

0.6115.6

163

6.42

1.5740

1195.08129

82 3.23

4.69

1.0025.4HEX

PressureEqualizationValve

5.39 137

8.23 209

4.02102

OUTLET

1/2"-20UNF-2B x 17DPINLET

1756.89

5.85

11.61295

6.69170

148.5

0.5915

148.5 5.85

7.87200

[12.00]HFDK4P-09 305 [21.00] 18 533 [30.00] 27 762Clearance requiredfor element removal

DimensionsHFDK4P 09, 18, 27…1.2

Page 71: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F71

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

00

2

4

12

10

8

6

14

18

16

20

0

0.2

0.4

0.6

0.8

1.0

1.2

10 20 4030 6050 8070 90

0 50 150100 200 250 300

Q (gpm)

HFDK4P Housing

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K FactorsP Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Autospec HF4 Depth 5.03.XXDXXBH (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

5.03.09DXXBH 0.207 0.146 0.089 0.0475.03.18DXXBH 0.097 0.068 0.041 0.0225.03.27DXXBH 0.063 0.044 0.027 0.014

All Element K Factors in psi / gpm.

Page 72: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F72

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Industrial

Railways

Features• DFFH Reverse bypass Flow models filter fluid in the forward

direction and bypass the filter element when the flow direction is reversed.

• DFFHM Bi-Directional model provides fluid filtering in both directions. There are separate filter elements for each direction.

• Inlet/outlet port options include SAE 4-bolt flange code 62, or SAE ports (DFFHM flange only) to allow easy installation without costly adapters.

• O-ring seals are used to provide positive, reliable sealing. A choice of O-ring materials (nitrile rubber, Fluorocarbon elastomer, and ethylene propylene rubber) provides compatibility with petroleum oils, synthetic fluids, water-glycols, oil/water emulsions, and high water based fluids.

• Screw-in bowl or lid, mounted below the filter head requires minimal clearance to remove the element for replacement; contaminated fluid cannot be washed downstream when element is serviced.

• Clogging indicators have no external dynamic seal. This results in high reliability due to magnetic actuation which eliminates a leak point.

• A poppet-type bypass valve, located in filter head, (optional) provides positive sealing during normal operation and fast opening during cold starts and flow surges.

DFFH & DFFHM SeriesReverse Flow Bypass & Bi-Directional Filters6090 psi • up to 100 gpm

DFFH FILTERREVERSE FLOW

CIRCUIT

DFFHM FILTERBI-DIRECTIONAL

CIRCUIT

BY-PASSVALVES

(OPTIONAL)

Technical SpecificationsMounting Method DFFH: 4 mounting holes

DFFHM: 8 mounting holesPort ConnectionDFFH 160/240/280DFFH 330/660/1320DFFHM 160/240/280DFFHM 330/660/1320

SAE-20, 1 1/4” SAE Flange Code 62SAE-24, 2” SAE Flange Code 621 1/4” SAE Flange Code 622” SAE Flange Code 62

Flow Direction Inlet: Side Outlet: SideConstruction MaterialsHeadSingle piece bowl “1.X” BowlTwo piece bowl “2.X” Housing Lid/Cap

Ductile iron

Steel

SteelSteel

Flow Capacity160240280330660/1320

42 gpm (160 lpm)63 gpm (240 lpm)74 gpm (280 lpm)87 gpm (330 lpm)100 gpm (378.5 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

6090 psi (420 bar)6000 psi (420 bar)Contact HYDAC Office

Element Collapse Pressure RatingBH4HC, VON, W/HC

3045 psid (210 bar)290 psid (20 bar)

Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)∆P = 116 psid (8 bar) (non-bypass appplication)

Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)

Page 73: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F73

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Clogging Indicator Model CodeVD 5 B . X / .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Model CodeDFFH BH/HC 160 G 3 B 1 . 0 / 12 .

Filter Type DFFH = Reverse Flow bypass Filter DFFHM = Bi-Directional Filter

Element Media ON = Optimicron® (Low Collapse) BH/HC = Betamicron® (High Collapse) W/HC = Wire Mesh V = Metal Fiber

Size and Nominal Connection DFFH DFFHM 160 = 1 1/4” SAE Port or Flange 160 = 1 1/4” Flange (only) 240 = 1 1/4” SAE Port or Flange 240 = 1 1/4” Flange (only) 280 = 1 1/4” SAE Port or Flange 280 = 1 1/4” Flange (only) 330 = 1 1/2” SAE Port or 2” Flange 330 = 2” Flange (only) 660 = 1 1/2” SAE Port or 2” Flange 660 = 2” Flange (only) 1320 = 1 1/2” SAE Port or 2” Flange 1320 = 2” Flange (only)

Type of Connection G = Threaded (not available for DFFHM) F = Flange

Filtration Rating (micron) 3, 5, 10, 20 = BH/HC, BN/HC 3, 5, 10, 20 = V 1, 3, 5, 10, 15, 20 = ON 25, 74, 149 = W/HC

Type of ∆P Clogging Indicator A, B, BM, C, D (Others available upon request)

Type Number 1 2 = 2 Piece Bowl (size 660/1320 only)

Modification Number (latest version is always supplied)

Port Configuration 12 = SAE Straight Thread O-Ring Boss Ports (available on DFFH only) 16 = SAE Flange Ports

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene rubber (EPR)

Bypass Valve (omit) = Non-bypass - Critical applications (high collapse element required) B3 = 43 psid (3 bar) - Optional B6 = 87 psid (6 bar) - Standard setting for pressure filters

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluid SO184 = G-1/2” Drain in Bowl Option For Sizes 160 - 280 (standard for sizes 330 & 660) W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100°F (C and D indicators only) cRUus = Electrical Indicator with underwriter’s recognition SFREE = Element specially designed to minimize electrostatic charge generation

Replacement Element Model Code 0160 D 003 BH4HC / Size 0160, 0240, 0280, 0330, 0660, 1320

Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = V 25, 74, 149 = W/HC

Element Media BH4HC, ON, V, W/HC

Seals (omit) = Nitrile rubber (NBR) (standard)

V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Page 74: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F74

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size - DFFH 160 240 280

Weight (lbs.) 25.6 29.2 39.6

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFH 160 / 240 / 280

4.57116

(Optional)

SAE 20 Flange code62 (1-1/4")

Drain PortG 1/2"

SAE 20 Thread or

[1.00]1/2"-13UNC-2B x 25.4 DP4 Places

66.72.63

1.2531.8

∆P Clogging Indicator PortG 1/2"

DFFH 240 12.05306

0.24

3.75

95.2

1.85

47.1

6

[19.17]DFFH 280 487

[9.68]DFFH 160 246

HEX 1.2632

4 Places

INLET

Mounting Holes [0.55]3/8-24UNF-2B x 14

OUTLET

3.3585

35 1.38

142.9

98.63.88

5.63

0.5614.2

for Element Removal

85Clearance required

[3.35]

Page 75: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F75

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

6.26159

∆P CloggingIndicator PortG 1/2"

0.24

[13.19]

6

130.2

177.4 6.98

19.88DFFH 330 335

DFFH 660

2.39

505

60.7

5.13HEX

1.4236

Two Piece Bowl

Clearance required

SAE Ported Version

for element removal

for element removal

DFFH 660 & 1320 2.X

95[3.74]

Clearance required

OUTLET

Flow)(FilteredINLET

[0.67]1/2-20UNF-2B IN. x 17 DP

6.3 160

4.53

115138

60 2.36

5.43

0.7118

Drain PortG 1/2"

1-7/8-12UNCSAE-24 PORT

G 1/2"Drain Port

Or SAE 32 flange code 62 (2")

SAE 24 Thread

[0.95]3/4-10UNC-2B x 24 DP4 Places

DFFH 1320 820 [32.28]

5.98

44.5

19.57497

2.3960.7

1124.41

1.75

DFFH 660

1325.2

152

3.8196.8

DFFH 1320 670 [26.38]

13.78350DFFH 660

0.24

6

Size - DFFH 330 660 1320

Weight (lbs.) 61.3 78.7 127

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFH 330 / 660 / 1320

Page 76: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F76

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size - DFFHM 160 240 280

Weight (lbs.) 59.1 66.3 77

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFHM 160 / 240 / 280

0.24

6

DFFHM 160 F 9.68

246 [12.05]DFFHM 240 F 306 [19.17] DFFHM 280 F 487

3.7595.2

16.73425

1.8547

HEX 1.2632

Drain PortG 1/2"(Optional)

5.63

142.9

3.3585

1.6742.5

5.47139

1.3835

11.1282

Mounting holes

3/8-24UNF-2B x0.5514

8 Places

0.6918

0.5614.2

0.5614.2

4.57116

∆ P Clogging Indicator PortG 1/2"2 Places

A3Flange bolt holes(4 Places)

A2

A1

[3.35]85Clearance requiredfor element removal

Size A1 A2 A3DFFHM 160/240/280 66.7±0.3 31.8±0.3 1/2-13UNC-2B x [1.00] 25.4 DP

Page 77: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F77

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size - DFFHM 330 660

Weight (lbs.) 139.4 175.5

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFHM 330 / 660

13.07332

6.77172

6.3160

2.3660

4.53115

2.2657.5

Mounting Holes

1/2-20UNF-2B x0.6717 DP

4 Places

0.7118

1.1830

6.26159

∆P CloggingIndicator Port G 1/2"2 Places

Inlet

0.24

6

DFFHM 300 [13.19]335

[19.88]DFFHM 660 505

2.3960.7

5.13130.2

HEX 1.4236

19.37492

A3Flange bolt holes(4 Places)

A2

A1

Drain PortG 1/2"

[3.74]95Clearance requiredfor element removal

Size A1 A2 A3DFFHM 160/240/280 66.7±0.3 31.8±0.3 1/2-13UNC-2B x [1.00] 25.4 DP

Page 78: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F78

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size - DFFHM 1320

Weight (lbs.) 271.2

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFFHM 1320

3/4-10UNC-2B x 0.9424 DP

1.9750

3.8196.8

1.7544.5

Flange Detail

6.26159

332 13.07

57.5

4.53

160 172

115

1.18

30

602.36

6.77 2.26

6.30

19.37492

6

5.98

60.7

819.4

2.39

132

152

32.26

5.20

[0.24]

4.41112

Drain PortG 1/2"

Indicator PortG 1/2"

HEX 1.4236

[26.38]670

Clearance Requiredfor Element Removal

Page 79: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F79

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

0.0

20.0

15.0

10.0

5.0

0 15 30 45 60 75 90Flow in gpm

DFFH 330/660/1320 Reverse Flow

0.0

20.0

15.0

10.0

5.0

0 20 40 60 80 100Flow in gpm

DFFH 330/660/1320 Forward FlowDFFH 160/240/280 Forward Flow

0 806040200

40

30

20

10

Flow in gpm

DFFH 160/240/280 Reverse Flow

0 806040200

40

30

20

10

Flow in gpm

DFFHM 330/660/1320 Forward & Reverse Flow

Flow in gpm0 150100500

50

40

30

20

10

DFFHM 160/240/280 Forward & Reverse Flow

Flow in gpm0

150

100

50

0 80604020

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

0160 D XXX ON 1.015 0.604 0.423 0.225 0.204 0.1750240 D XXX ON 0.631 0.379 0.293 0.175 0.134 0.1150280 D XXX ON 0.304 0.185 0.15 0.082 0.075 0.0640330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015

Betamicron ...D…BH4HC (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022

Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012

Wire Mesh ...D…W/HC Elements Size 25, 50, 74, 100, 149, 200 µm

0160 D XXX W/HC 0.0160240 D XXX W/HC 0.0100280 D XXX W/HC 0.0090330 D XXX W/HC 0.0080660 D XXX W/HC 0.0041320 D XXX W/HC 0.002

All Element K Factors in psi / gpm.

Page 80: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F80

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Industrial Railways Steel / HeavyIndustry

Features• The DF...QE Filters have a filter head of ductile iron and a

screw-in bowl of cold-formed steel for high fatigue strength.• The filter housings are designed to withstand pressure surges

as well as high static pressure loads.• The screw-in bowl or lid/cap allows the filter element to be easily

removed for replacement or cleaning.• Visual (pop-up), electrical, electrical/visual (lamp), or electronic

differential type clogging indicators can be installed.• DF...QE filters are available with or without a bypass valve

located in filter head, so either high or low collapse pressure elements may be used.

• Fatigue pressure rating equals maximum allowable working pressure rating.

DF...QE SeriesManifold Mount Filters4568 psi • up to 110 gpm

A

B

Technical SpecificationsMounting Method 4 mounting holes (manifold mount)

Port Connection Diameters3060/110160/240/280330/660/1320

0.551” (14mm)0.787” (20mm)1.260” (32mm)1.181” (30mm)

Flow Direction Inlet: Side Outlet: SideConstruction MaterialsHeadSingle piece bowl “1.X” BowlTwo piece bowl “2.X” Housing Lid/Cap

Ductile iron

Steel

SteelSteel

Flow Capacity30601101602402803306601320

8 gpm (30 lpm)16 gpm (60 lpm)29 gpm (110 lpm)42 gpm (160 lpm)63 gpm (240 lpm)74 gpm (280 lpm)87 gpm (330 lpm)100 gpm (378.5 lpm)110 gpm (416.4 lpm)

Housing Pressure Rating QE MHEMax. Allowable Working PressureFatigue Pressure

Burst Pressure

4568 psi (315 bar)4568 psi (315 bar) @ 1 mil. cyclesContact HYDAC

3625 psi (250 bar)3625 psi (250 bar) @ 100 mil. cycles

Element Collapse Pressure RatingBH4HC, VON, W/HC

3045 psid (210 bar)290 psid (20 bar)

Fluid Temperature Range 14ºF to 212ºF (-10ºC to 100ºC)Consult HYDAC for applications operating below 14°F (-10°C)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 29 psid (2 bar) -10% (optional)∆P = 72 psid (5 bar) -10% (standard)

Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional)∆P = 87 psid (6 bar) +10% (standard)

Page 81: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F81

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeDF BH/HC 30 Q E 3 B 1 . X / .

Filter Type DF

Element Media ON = Optimicron® (Low Collapse) BH/HC = Betamicron® (High Collapse) V = Metal Fiber W/HC = Wire Mesh

Size 30, 60, 110, 160, 240, 280, 330, 660, 1320

Operating Pressure Q = 4500 psi (300 bar) MH = 3625 psi (250 bar) (high dynamic @ 100 million cycles)

Type of Connection E = Manifold Block Mounting - Side of Filter Head - 4 mounting holes

Filtration Rating (microns) 3, 5, 10, 20 = BH/HC 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = V 25, 74, 149 = W/HC

Type of ∆P Clogging Indicator A, B, BM, C, D (Others available upon request)

Type Number 1 = Filters with one piece bowls (sizes 30-660) 2 = Filters with two piece bowls (sizes 660-1320)

Modification Number (the latest version is always supplied)

Seals (omit = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Bypass Valve (omit) = Without Bypass (BH4HC or V elements recommended) B3 = 43 psid Bypass (optional) B6 = 87 psid Bypass (standard)

Supplementary Details SO263 = Modification of ON, BH/HC & W/HC elements for Skydrol or HYJET phosphate ester fluids SO184 = G-1/2 Drain in Bowl Option For Sizes 30 - 280 (standard for sizes 330 - 1320) W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100°F (C and D indicators only) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with underwriter’s recognition

Replacement Element Model Code 0030 D 003 BH4HC / Size

0030, 0060, 0110, 0160, 0240, 0280, 0330, 0660, 1320

Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = V 25, 74, 149 = W/HC

Element Media BH4HC, ON, V, W/HC

Seals (omit) = Nitrile rubber (NBR) (standard)

V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 5 B . X / .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 82: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F82

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 30 60 110 160 240 280

Weight (lbs.) 6.4 11.5 13.5 21.2 25.6 35.1

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 30 – 280 QE 1.X

[4.57]

DF 30 QE[2.64]

67

DF 60/110 QE[3.31]

84

DF 160/240/280 QE

116

[4.37]

DF 160/240/280 QE

DF 30 QE[3.15]

80

DF 60/110 QE

110

[2.83]

DF 160/240/280 QE

DF 30 QE[2.44]

57

DF 60/110 QE

72

111

DF 30 QE[3.66]

93

DF 60/110 QE[4.37]

DF 160/240/280 QE

HEX

6.22

DF30 QE

DF60/110

158

DF160/240/280

DF30 QE

DF60/110QE

DF160/240/280 QE

Indicator PortG 1/2"

Clearance required

48

[3.75]

DF 30 QE

85

79 [3.11]

DF 280 QE

[2.17]

[1.38]DF60/110 QE

28[1.10]

Mounting Pattern

DF 160 QE

55DF 160/240/280 QE

[1.26]DF 160/240/280 QE

[1.50]

75 [3.35]DF 160/240/280

35DF 160/240/280 QE

[1.77]

for element removal

45DF60/110 QE

[1.06]DF60/110 QE 27

95.2

38

[1.89]

68.2524

343[13.50]

DF 240 QE283

[2.05]

60

[20.62]

[11.14]

DF 30/60/110 [2.95]

32

DF 30 QE

52

[2.36]

DF 30 QE[7.72]196

DF 60 QE[8.62]219

DF 110 QE[11.34]

288

[0.94]DF30 QE 24

[2.05]52.2[2.68]

(Optional SO184)

OUTLET

Drain PortG 1/2" DF60-280G 1/4" DF30

INLET

5.51140

22

DF 160/240/280 QE[0.866]

[0.709]18

DF 30 QE[0.512]

13DF 60/110 QE

DF 30 QE DF 60/110 QE [0.551] [0.79] 14 20 DF 160/240/280 QE [1.26] 32

3.7495

Page 83: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F83

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 330 660

Weight (lbs.) 50.5 75.2

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 330 – 660 QE 1.X

DF 330 QE 14.06

357

DF 660 QE [20.70] 526

0.16

4

HEX 1.4236

[4.53]115Clearance requiredfor element removal

5.12130

1546.06

3.1379.5

G 1/2" (Standard)Drain Port

2.0552

95

2.28

3.74

1405.51

58

0.9123

Indicator PortG 1/2"

OUTLET

INLET

Page 84: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F84

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 660 1320

Weight (lbs.) 50.5 75.2

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 660 – 1320 QE 2.X

HEX1.4236

Indicator PortG 1/2"

∆ P Clogging

Drain PortG 1/2"

3.13

5.2

79.5

132

6.16

156.5

for elemental removalClearance required650 DF1320 QE

[13.82]351 DF 660 QE

[25.59]

40.16

2.2858

[20.31]

2.0595

DF 1320 QE

5.98

32.99

DF 660 QE 516

4.41

152

112

1405.51

838

3.74

52

6.06154

Page 85: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F85

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

DF...QE 30

0.4

0 0.0

24

18

12

6

0.8

1.2

1.60

0

10 20 30 40 50 60

161284

Q in l/min

Q in gpm Q in gpm

DF...QE 60/110Q in l/min

0

3

6

9

0.2

0.4

0.60 10 20 30 40 50 60 70

0 3 6 9 12 15 18

DF...QE 330/660/1320Q in l/min

0.40

27

18

9 0.8

1.2

1.4

1.60

0 44 66 88 110 13222

100 200 300 400 500

DF...QE 160/240/280Q in l/min

0.1

0.2

0.3

0.4

0.50 40 80 120 160

0 186 12 30 3624 420

7.5

5.0

2.5

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Wire Mesh ...D…W/HC Elements (Low Collapse)Size 25, 50, 74, 100, 149, 200 µm

0030 D XXX W/HC 0.1660060 D XXX W/HC 0.0420110 D XXX W/HC 0.2300160 D XXX W/HC 0.0160240 D XXX W/HC 0.0100280 D XXX W/HC 0.0090330 D XXX W/HC 0.0080660 D XXX W/HC 0.004

1320 D XXX W/HC 0.002

Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0030 D XXX BH4HC 5.005 2.782 1.992 1.0430060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.3070160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022

Metal Fiber ...D…V Elements (High Collapse)

Size 3 µm 5 µm 10 µm 20 µm0030 D XXX V 1.011 0.740 0.411 0.2000060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.1180160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012

Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

0030 D XXX ON 4.27 3.507 2.376 1.251 0.768 0.620060 D XXX ON 2.936 1.427 1.004 0.664 0.537 0.3470110 D XXX ON 1.416 0.735 0.527 0.333 0.254 0.1640160 D XXX ON 1.015 0.604 0.423 0.225 0.204 0.1750240 D XXX ON 0.631 0.379 0.293 0.175 0.134 0.1150280 D XXX ON 0.304 0.185 0.15 0.082 0.075 0.0640330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015

All Element K Factors in psi / gpm.

Page 86: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F86

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Construction Industrial

Railways

PowerGeneration

Steel / HeavyIndustry

Features• The filter housings are designed to withstand pressure surges as

well as high static pressure loads.• The screw-in bowl or lid/cap allows the filter element to be easily

removed for replacement or cleaning.• A visual (pop-up), electrical, electrical/visual (lamp), or electronic

differential type clogging indicator can be installed.• DFP filters are available with or without a bypass valve (located in

filter head) so either high or low collapse pressure elements may be used.

• Multiple indicator port locations (DFP330/660/1320 only) also allow two different types of indicators to be installed into the filter. Indicators of the same type, but with different trip pressures can also be installed. (both ports machined and plugged)

• Fatigue pressure rating equals maximum allowable working pressure rating.

DFP SeriesManifold Mount Filters4568 psi • up to 125 gpm

A

B

Technical SpecificationsMounting Method 60 - 280 330 - 1320

(manifold mount)4 mounting holes6 mounting holes

Port Connection Diameter60/110160/240/280330/660/1320

0.689” (17.5mm)0.843” (21.4mm)1.181” (30mm)

Flow Direction Inlet: Top Outlet: Top Construction Materials Head Bowl Housing (660-1320) Cap/Lid (660-1320)

Ductile ironSteelSteelLow Carbon Steel

Flow Capacity 60 110 160 240 280 330 660 1320

16 gpm (60 lpm)29 gpm (110 lpm)42 gpm (160 lpm)63 gpm (240 lpm)74 gpm (280 lpm)87 gpm (330 lpm)174 gpm (660 lpm)180 gpm (680 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue Pressure

4568 psi (315 bar)4568 psi (315 bar) @ 1 milllion cycles

Burst Pressure 60/110160/240/280330/660/1320

15,805 psi (1090 bar)>18,000 psi (1240 bar)15,660 psi (1080 bar)

Element Collapse Pressure RatingBH4HC, VON, W/HC

3045 psid (210 bar)290 psid (17 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.Indicator Trip Pressure ∆P = 29 psid (2 bar) -10% (optional) ∆P = 72 psid (5 bar) -10% (standard)

Bypass Valve Cracking Pressure∆P = 43 psid (3 bar) +10% (optional))∆P = 87 psid (6 bar) +10% (standard)

Page 87: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F87

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeDFP BH/HC 60 Q B 3 B 1 . X / V .

Filter Type DFP = Manifold mount filter

Element Media ON = Optimicron® (Low Collapse) BH/HC = Betamicron® (High Collapse) W/HC = Wire Mesh V = Metal Fiber

Size and Nominal Port Dimension 60 = 3/4” 280 = 1” 110 = 3/4” 330 = 1 1/4” 160 = 1” 660 = 1 1/4” 240 = 1” 1320 = 1 1/4”

Operating Pressure Q = 4500 psi (315 bar)

Port Size B = 0.69 (sizes 60 - 110) C = 0.84 (sizes 160 - 280) D = 1.18 (sizes 330 - 1320)

Filtration Rating (microns) 3, 5, 10, 20 = BH/HC 3, 5, 10, 20 = V 25, 74, 149 = W/HC 1, 3, 5, 10, 15, 20 = ON

Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)

Type Number 1 = Single piece bowl (sizes 60 - 660) 2 = Two piece bowl (size 330, 660 & 1320 only)

Modification Number (the latest version is always supplied)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Bypass Valve (omit) = Without Bypass (BH4HC or V elements recommended) B3 = 43 psid Bypass (optional) B6 = 87 psid Bypass (standard)

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids SO184 = G-1/2 Drain in Bowl Option For Sizes 60 - 280 (standard for sizes 330, 660, & 1320) W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) T100 = Indicator Thermal Lockout, 100°F (C and D indicators only) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with underwriter’s recognition

Replacement Element Model Code 0060 D 003 BH4HC / V Size 0060, 0110, 0160, 0240, 0280, 0330, 0660, 1320

Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 25, 74, 149 = W/HC 3, 5, 10, 20 = V 1, 3, 5, 10, 15, 20 = ON

Element Media BH4HC, ON, V, W/HC

Seals (omit) = Nitrile rubber (NBR) (standard)

V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above) SFREE = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 5 B . X / V .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 2 = 29 psid (2 bar) (option) 5 = 72 psid (5 bar) (standard) Optional 116 psid (8 bar) available upon request

Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only L24 = 24V L110 = 110V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with underwriter’s recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 88: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F88

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 60 110 160 240 280

Weight (lbs.) 11.3 13.3 20.1 23 32.5

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFP 60 – 280…1.X

60/110 160/240/260 [4.09] [4.53] 104 115

DFP 60/110 [2.95] 75DFP 160/240/280 [3.35] 85Clearance requiredfor element removal

HEX

P Clogging Indicator PortG 1/2"

G 1/2"Drain PlugOptional (SO184)

68.2

DFP 280 444

DFP 160 203

DFP [17.48] 3.75

95.2

10.35263DFP 240

[7.99]

160/240/280

[6.30]DFP 60 160 [9.06]DFP 110 230

DFP [2.68] 60/110

0.24

6

[1.06] DFP60/110 27

DFP 160/240/280 1.26

32

OUTLET

INLET

b14

b9

b10

Mounting Holesd4 THRU

4 Places

b13

b3 b5

b6

b7

b11

b15

b4

b12

b8

D5 x T1/T2Mounting Holes4 Places

60 / 110 160 / 240 / 280

B3 [3.15] 80

[4.33] 110

B4 [3.50] 89

[3.54] 90

B5 [1.25] 31.8

[3.39] 86

B6 – [2.40] 61

B7 – [2.24] 57

B8 [1.24] 31.6

[1.50] 38

B9 – [0.55] 14

B10 [0.30] 7.5

[0.49] 12.5

B11 [2.20] 55.9

[2.26] 57.5

B12 – [0.35] 9

B13 [0.95] 24.1

[0.47] 12

B14 – [1.04] 26.5

B15 – [0.41] 10.5

ø d4 [0.33] 8.5

[0.35] 9

ø d5 - 7/16-14UNC-2B

t1 - [0.51] 13

Inlet [0.639] 17.5

0.843” 21.4

Outlet [0.689] 17.5

[0.843] 21.4

Page 89: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F89

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 330 660

Weight (lbs.) 46.3 64

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFP 330/660…1.X

0.7519

96.8 3.81

48.4 1.91

21.40.84

301.18

50.7

1.18

2.00

306 Places

HolesMounting

11.50.45

84.1

3.31

42.11.66

16.70.66

Pin Hole)(Locating

60.24

6.61168

element

INLET

OUTLET

required for

removal

[3.74]95

Clearance

∆ P Clogging Indicator PortsG 1/2" 2 Places(Both Machined)

G 1/2"Drain Plug

20.24514

1586.22

[13.54]DFP 330 344

DFP 660

5.13130.2

HEX 1.4236

Page 90: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F90

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 660 1320

Weight (lbs.) 64 103.9

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DFP 660 & 1320…2.X

HEX 1.4236

G 1/2"Drain Plug

5.20132

∆ P Clogging Indicator Ports G 1/2"2 Places(Both Machined)

DFP 1320 32.48

152

6.22

DFP 660 503

5.98

825

158

[19.80]

4.41112

OUTLET

INLET

[13.78]DFP 660 350

[26.38] DFP 1320 670

Clearancerequired

for elementremoval

6 Places

0.45

Mounting Holes0.66

1.1896.8

3.81

190.75

50.72.0021.4

0.84

48.41.91

42.1

1.66

11.51.18

3.31

30

84.1

30

16.7

6.61168

Page 91: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F91

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

30

20

10

0 5 10 15 20 25 30Q in gpm

DFP 60/110 Housing

60

40

20

DFP 160/240/280 Housing

Q in gpm0 10 20 30 40 50 60 0 50 100 150 200

30

20

10

DFP 330/660/1320 Housing

Q in gpm

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Wire Mesh ...D…W/HC Elements (Low Collapse)Size 25, 50, 74, 100, 149, 200 µm

0060 D XXX W/HC 0.0420110 D XXX W/HC 0.2300160 D XXX W/HC 0.0160240 D XXX W/HC 0.0100280 D XXX W/HC 0.0090330 D XXX W/HC 0.0080660 D XXX W/HC 0.0041320 D XXX W/HC 0.002

Optimicron …D…ON ElementsSize 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm

0060 D XXX ON 2.936 1.427 1.004 0.664 0.537 0.3470110 D XXX ON 1.416 0.735 0.527 0.333 0.254 0.1640160 D XXX ON 1.015 0.604 0.423 0.225 0.204 0.1750240 D XXX ON 0.631 0.379 0.293 0.175 0.134 0.1150280 D XXX ON 0.304 0.185 0.15 0.082 0.075 0.0640330 D XXX ON 0.452 0.23 0.185 0.135 0.085 0.0670660 D XXX ON 0.207 0.106 0.086 0.051 0.039 0.0311320 D XXX ON 0.102 0.053 0.042 0.025 0.019 0.015

Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.3070160 D XXX BH4HC 0.922 0.571 0.324 0.2410240 D XXX BH4HC 0.582 0.373 0.214 0.1590280 D XXX BH4HC 0.313 0.187 0.099 0.0880330 D XXX BH4HC 0.423 0.247 0.154 0.1100660 D XXX BH4HC 0.181 0.104 0.055 0.0491320 D XXX BH4HC 0.088 0.055 0.033 0.022

Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.1180160 D XXX V 0.251 0.177 0.123 0.0790240 D XXX V 0.169 0.137 0.093 0.0620280 D XXX V 0.126 0.093 0.064 0.0410330 D XXX V 0.121 0.097 0.065 0.0430660 D XXX V 0.063 0.050 0.034 0.0211320 D XXX V 0.032 0.026 0.018 0.012

All Element K Factors in psi / gpm.

Page 92: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F92

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction Industrial

Railways PowerGeneration

Steel / HeavyIndustry

Features• A visual (pop-up), electrical, electrical/visual (lamp) differential

type clogging indicator can be installed.• The DFZ filter can be ordered with the bowl on the left or the

right side for easy element changeout.• The DFZ filter is available in two mounting patterns to fit

different hydraulic manifolds: ANSI/B93.7M-D03 / Cetop R35 (was B93.7-D01) DF 30 Z ANSI/B93.7M-D05 / Cetop R35 (was V93.7-D02)* DF 60 Z or DF 110 Z *includes fifth port for optional tank connection

• Filter does not contain a bypass valve. Only available with non bypass, high collapse elements required.

DFZ SeriesModular Stacking Filters4568 psi • up to 10 gpm

INLETT A B TP

OUTLET

INLETT A BP

OUTLET

Technical SpecificationsMounting Method 4 mounting holes (manifold mount)

Port Connection30 ø.25”60/110 ø.44”

ANSI DO3/A6 DIN 24340 / Cetop R35ANSI DO5/A10 DIN 24340 / Cetop R35

Flow Direction Inlet: Side Outlet: Side Construction MaterialsHead, Bowl Steel

Flow Capacity30 6 gpm (23 lpm)60/110 10 gpm (38 lpm)

Housing Pressure RatingMax. Allowable Working Pressure 4568 psi (315 bar)Fatigue Pressure 30

60/110

4568 psi (315 bar) @ 250,000 cycles4568 psi (315 bar) @ 1 million cycles

Burst Pressure > 18,270 psi (1260 bar)Element Collapse Pressure RatingBH4HC, V 3045 psid (210 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Indicator Trip Pressure∆P = 116 psid (8 bar) -10% (standard)

Page 93: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F93

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model Code DFZ BH/HC 60 Q C 10 B 1 . 0 / - 1 - Filter Type DFZ = Pressure Filter

Element Media BH/HC = Betamicron® (High Collapse) V = Metal Fiber

Size & Connection 30 = D03 manifold pattern 60 = D05 manifold pattern 110 = D05 manifold pattern

Operating Pressure Q = 4500 psi (315 bar) (all sizes)

Type / Port Size B = 4 ports / A 6 DIN 24340/Cetop R 35 H (DFZ 30 only) .25” dia. C = 5 ports / A 10 DIN 24340/Cetop R 35 H (DFZ 60 & 110 only) .44” dia.

Filtration Rating (micron) 3, 5, 10, 20 = BH/HC 3, 5, 10, 20 = V

Type of ∆P Clogging Indicator A, B, BM, C, D (others available upon request)

Type Number 1

Modification Number (latest version is always supplied)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Bowl Location (omit) = Right Side (standard) 1 = Left Side

Supplementary Details SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) SFREE = Element specially designed to minimize electrostatic charge generation cRUus = Electrical Indicator with Underwriter’s Recognition

Replacement Element Model Code 0060 D 010 BH4HC / Size 0030, 0060, 0110

Filtration Rating (micron) 3, 5, 10, 20 = BH4HC 3, 5, 10, 20 = V

Element Media BH4HC, V

Seals (omit) = Nitrile rubber (NBR) (standard)

V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)

Supplementary Details SO263 = (same as above)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Clogging Indicator Model CodeVD 8 B . X / .

Indicator Prefix VD = G 1/2 6000 psiTrip Pressure 8 = 116 psid (8 bar)Type of Indicator B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and led light - SPDTModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L48 = 48V L110 = 110V L220 = 220V Thermal Lockout (VM, VD types C, D, J, and J4 only) T100 = Lockout below 100°F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cRUus = Electrical Indicator with Underwriter’s Recognition

W = “VD…” indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC)

(For additional details and options, see Section G - Clogging Indicators.)

Page 94: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F94

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 30

Weight (lbs.) 5.3

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 30 Z

B

P

A

B

A

A

P

T

P

B

T

T

311.22

1.0927.8

32.5

0.236

10.30.2095.3

4 Places

26.6

40.5

1.05

19 0.75

16.30.641.59

0.41

1.28

THRU

0.030.8

Indicator PortG 1/2"

0.4812.2

1.8948

0.37.6

1.0627

for element removal

[1.77] 45Clearance required

INLET Face

2208.66

0.24

6

1.8146

(Left Hand Version) - (optional)

D03 Pattern

(Right Hand Version) - (optional)

Page 95: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F95

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Size 60 110

Weight (lbs.) 13.1 15

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Dimensions DF 60 / 110 Z

P

TT

A B

P

TT

A B

P

BA

TT

[9.88]DF 110 Z

[12.63]321

DF 60 Z

251

HEX 1.0627

D05 Pattern

21.40.84

1.28 32.5

16.7 0.66

0.133.2

542.13

200.79

2

50.8

37.31.47

0.25

6.3

271.06

461.81

0.4712

Indicator PortG 1/2"

5 Places

0.6215.7

0.410.2

D05 Pattern

[3.15]80Clearance requiredfor element removal

0.26

6

68.2

Mounting through6.6Holes (4 Places)

702.76

0.24

2.69

Indicator PortG 1/2"

P

TT

A B

P

TT

A B

P

BA

TT

[9.88]DF 110 Z

[12.63]321

DF 60 Z

251

HEX 1.0627

D05 Pattern

21.40.84

1.28 32.5

16.7 0.66

0.133.2

542.13

200.79

2

50.8

37.31.47

0.25

6.3

271.06

461.81

0.4712

Indicator PortG 1/2"

5 Places

0.6215.7

0.410.2

D05 Pattern

[3.15]80Clearance requiredfor element removal

0.26

6

68.2

Mounting through6.6Holes (4 Places)

702.76

0.24

2.69

Indicator PortG 1/2"(Left Hand Side Version) - (optional)

D05 Pattern

(Right Hand Side Version) - (standard)

Page 96: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F96

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

60

50

40

30

20

10

Q in gpm

DFZ 30 Housing DFZ 60 / 110 Housing

6543210 7 20151050

80

60

40

20

Q in gpm

Sizing InformationTotal pressure loss through the filter is as follows:

Assembly ∆P = Housing ∆P + Element ∆P

Housing Curve:

Pressure loss through housing is as follows:

Housing ∆P = Housing Curve ∆P x Actual Specific Gravity

0.86

Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)

Element K Factors∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x

Actual Viscosity (SUS) x Actual Specific Gravity (From Tables Below) 141 SUS 0.86

Metal Fiber ...D…V Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0030 D XXX V 1.011 0.740 0.411 0.2000060 D XXX V 0.877 0.511 0.296 0.1830110 D XXX V 0.452 0.304 0.182 0.118

Betamicron ...D…BH4HC Elements (High Collapse)Size 3 µm 5 µm 10 µm 20 µm

0030 D XXX BH4HC 5.005 2.782 1.992 1.0430060 D XXX BH4HC 3.216 1.789 0.993 0.6700110 D XXX BH4HC 1.394 0.818 0.489 0.307

All Element K Factors in psi / gpm.

Page 97: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F97

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Notes

Page 98: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F98

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Construction Industrial

Railways

CommercialMunicipal

Features• Made of aluminum for light weight and low cost.• Made to dispose of when fully clogged.• Low price - market competitive.

CF SeriesManifold Cartridge Filters3000 psi • up to 25 gpm

A

B

CFxx20 CFxx45

Technical SpecificationsPort Connections CF20

CF45SAE-16 Modified CavitySAE-20 Cavity (VC20-S3)

Direction of Flow Outside to Inside flowMaterials of Construction AluminumFlow CapacityCF20

CF45

5 GPM (15 micron - fiberglass media)2.5 GPM recommended design flow max. - for high efficiency media12 GPM (25, 149 micron - wire screen media)12 GPM (15 micron - fiberglass media)6 GPM recommended design flow max. - for high efficiency media25 GPM (25, 149 micron - wire screen media)

Housing Pressure RatingMax. Allowable Working Pressure:Proof Pressure:

3000 psi (207 bar)4500 psi (310 bar)

Element Performance RatingMM, W 290 psid (20 bar)

Fluid Temperature Range -22°F to 250°F (-30°C to 121°C)Consult HYDAC for applications operating below -22ºF (-30ºC)

Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Page 99: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F99

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeCF W 20 G 25 W 1 . 0 / 12 .

Filter Type CF = Manifold Cartridge Filter

Element Media MM = Mobilemicron® W = Wire Mesh

Size 20, 45

Type of Connection G = Threaded

Filtration Rating (micron) 25, 149 = W 15 = MM

Type of Indicator W = No Indicator Available

Type Number 1 = Standard Configuration

Modification Number (latest version always supplied)

Port Configuration 12 = SAE-16 Modified Cavity (CF 20) 12 = SAE-20 Cavity (VC20-S3) (CF 45)

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

1.0

0.8

0.5

0.3

0.0

1.3

0 3 6 9 12 15

18.0

15.0

12.0

9.0

6.0

3.0

0.0

21.0

0 1 2 3 4

CFMM20G15W1.0/12Q in l/min

Q in gpm

1.0

0.8

0.5

0.3

0.0

1.3

0 10 20 30 40 50 60

18.0

15.0

12.0

9.0

6.0

3.0

0.0

21.0

0 3 6 9 12 15 18

CFW20G25/149W1.0/12Q in l/min

Q in gpm

1.0

0.8

0.5

0.3

0.0

1.3

0 5 10 15 20 25 30 35 40 45 50 55

18.0

15.0

12.0

9.0

6.0

3.0

0.0

21.0

0 3 6 9 12 15

CFMM45G15W1.0/12Q in l/min

Q in gpm

1.0

0.8

0.5

0.3

0.0

1.3

0 10 20 30 40 50 60 70 80 90 130120110100

18.0

15.0

12.0

9.0

6.0

3.0

0.0

21.0

0 5 10 15 20 25 30 35

CFW45G25/149W1.0/12Q in l/min

ΔP

in b

arΔ

P in

bar

ΔP

in b

ar

ΔP

in p

sid

ΔP

in p

sid

ΔP

in p

sid

ΔP

in p

sid

ΔP

in b

ar

Q in gpm

Pressure Drop Curves

Page 100: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F100

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Dimensions CFxx20

Size 20

Weight (lbs.) 0.5

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

572.24

of the Fitting

2.6066

Min Depth

35.5+ 0.10

1.398+-0.0040.000

15°

1.50" HEX

INLET

2.63

25.4

67

1.00

1-5/16-12UN-2A IN.

3.1680.2

Ra1

.6

A

A

0.05

Ra1.6

A

0.1

OUTLET

Ra1

.6

0.05A

Z

19

1-5/16-12UN-2B IN.

49Spot Face

From 30 to 41

R0.20.008

1.93

0.79 MIN20 MIN

68.5

25.5±0.1

0.8

19

2.70

1.003±0.002

0.03

Pilot Drill

0.75

0.75

[1.18] [1.64]

20°

DETAIL ZSCALE 1.5 : 1

Ra1

.6

0.008R0.2

0.13+-0.0120.000

3.3+ 0.30

45°±5°

Page 101: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F101

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Dimensions CFxx45

Size 45

Weight (lbs.) 0.5

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

66 2.598

1.713±0.00443.5±0.1

15°±1°

A

A

INLET

Z

0.1

OUTLET

0.05

Ra1

.6

A

Ra1.6

0.1A

X

2.283

1.313

SAE-20 PORT

MAX

1.187

3.059

0.79 MIN20 MIN

33.35

1 5/8"-12UN-2B IN.

2.293

58

77.7

0.031

+

0.8

0+0.000

-0.002

0.051

30.15

SPOTFACE58

1.0025.4

SCALE 1.5 : 1DETAIL Z

Ra1

.6

0.3 +

45°

0

0.134+-0.0120.000

3.4

0.008R0.2

SCALE 4 : 1DETAIL X

Ra1

.6

20°

0.008R0.2

2.0051 HEX

3.52

76.23.00

89.4

33.3

1.311

1-5/8"-12UN-2A IN.

From [1.497]

38 to

[1.969]50

Page 102: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F102

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction

Features• Simple cost effective method of component protection with

minimal space requirements, eliminating design restraints.• Fits into a standard manifold Cavity No. C16-2 Port.• CP Circuit Protector Filters provide backup protection when

upstream pressure filters go into bypass or if element damage occurs.

• Two (2) different element options: 10 micron, and 141 micron allow filter to be tailored to individual application needs.

• Suitable for petroleum based fluids.• Flow Path - inside to outside.

CP-C16 SeriesCircuit Protector Manifold Cartridge Filters3000 psi • up to 12 gpm

A

B

Technical SpecificationsMounting Method C16-2 Cavity (SAE-16 Threaded Port)Flow Direction Inlet: Bottom Outlet: SideConstruction Materials SteelFlow Capacity 12 gpm (45 lpm)Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

3000 psi (210 bar)Contact HYDAC OfficeContact HYDAC Office

Element Collapse Pressure RatingW/HC 250 psid (17 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all petroleum oils rated for use with Nitrile rubber (NBR) seals.

Page 103: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F103

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeCP-C16 W 40 G 10 W 1 . 0 / 12 .

Filter Type CP-C16 = Circuit Protector (Common Cavity No. C16-2)

Element Media W = Wire Mesh

Size 40 Inline Port G = 1” Male Thread 1 5/16-12UN-2A (SAE-16)

Filtration Rating (micron) 10 = 10 micron 141 = 141 micron

Bypass Indicator W = No indicator Port

Type Number 1 = Standard Configuration

Modification Number

Port Configuration 12

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

00

10

20

30

40

50

6010 µm

141 µm

4 8 12

Q in gpm

Pressure Drop Curves

Based on testing conducted with 150 SUS fluid at 105˚F.

Page 104: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F104

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Dimensions CP-C16

1.126+-0.0020.000

28.6+0.050

0.5313.5

1.844 MIN46.84 MIN

1.3434

0.7519

0.13 MAX3.2 MAX

0.14±0.0083.5±0.2

1.9349

1.4±0.00235.55±0.05

1-5/16-12UN-2B IN.

20°

1.2231

0.03R0.75

0.5313.5

0.9724.6

15°

[0.06]R1.5

1.6

0.002 A

0.05 A

[ ]

0.004 A

0.1 A

[ ]

0.008 A

0.2 A

[ ]

A

1.1228.52

2.2958.3

0.4912.5

1-5/16-12UN-2A IN.

1.538.1 HEX

Size 40

Weight (lbs.) 0.75

Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.

Installation Torque:200 lb – ft into Steel Block

155 lb – ft into Aluminum Block

Page 105: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F105

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Notes

Page 106: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F106

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Hydraulic Symbol

Applications

Agricultural Automotive Construction

Features• Simple cost effective way to provide component protection with

minimal space required eliminating design restraints.• Fits into a standard manifold SAE O-ring Port.• CP Circuit Protector Filters provide backup protection when

upstream pressure filters go into bypass or if element damage occurs.

• CP-SAE provides operations protection through supply of a bypass to assure flow to critical components if filter becomes clogged.

• Increased range of product use through three (3) different sizes available, 15 at 4 gpm, 40 at 12 gpm, and size 120 at 30 gpm.

• Suitable for petroleum based fluids.• Flow Path - inside to outside.

CP-SAE SeriesCircuit Protector Manifold Cartridge Filters6090 psi • up to 30 gpm

B

A

Technical SpecificationsMounting MethodCP-SAE-15CP-SAE-40CP-SAE-120

SAE-10 Port (5/8”)SAE-16 Port (1”)SAE-24 Port (1 1/2”)

Flow Direction Inlet: Bottom Outlet: SideConstruction MaterialsCP-SAE-15CP-SAE-40CP-SAE-120

Carbon steel Carbon steel Stainless steel

Flow CapacityCP-SAE-15CP-SAE-40CP-SAE-120

4 gpm (15 lpm)12 gpm (45 lpm)30 gpm (113 lpm)

Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure

6090 psi (420 bar)Contact HYDAC OfficeContact HYDAC Office

Element Collapse Pressure RatingW 100 psid (6.9 bar)

Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility Compatible with all petroleum oils rated for use with Nitrile rubber (NBR) seals.

Bypass Valve Cracking Pressure∆P = 50 psid (3.4 bar) +10% (standard)

Replacement ElementsPart Number Description Flow Rate

02069397 0015 D 010 W 0015 - 4 gpm02069398 0040 D 010 W 0040 - 12 gpm02069399 0120 D 010 W 0120 - 30 gpm

Page 107: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F107

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model CodeCP-SAE W 15 G 10 W 1 . 0 / 12 B3.5 .

Filter Type CP-SAE = Circuit Protector (SAE O-ring Port)

Element Media W = Wire Mesh

Size 15 = 4 gpm 40 = 12 gpm 120 = 30 gpm

Inline Port G = Male Threaded

Filtration Rating (micron) 10 = 10 micron 75 = 75 micron 149 = 149 micron

Bypass Indicator W = No indicator Port

Type Number 1 = Standard Configuration

Modification Number

Port Configuration 12 Bypass Valve B3.5 = 50 psi

Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)

Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability

Pressure Drop CurvesBased on testing conducted with 150 SUS fluid at 105˚F.

00

10

20

30

40

50

0

75/141 µm

0.68

2.06

3.44

10 µm

2 4 6 8 10

0 7.57 20.8 33.1

Q (gpm)

CP-SAE 15

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

10

50

20

30

40

0

75/141 µm

0.68

10 µm

2.06

3.44

5 10 15 20

0 18.9 37.8 56.7 75.6

Q (gpm)

CP-SAE 40

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

00

10

20

30

40

50

0

0.68

2.06

75/141 µm

10 µm

3.44

10 20 30 40

0 37.8 75.6 113.4 151.2

Q (gpm)

CP-SAE 120

ΔP

in p

si

ΔP

in b

ar

Q (l/min)

15 = 5/8” SAE 10 Port-Threaded40 = 1” SAE 16 Port-Threaded120 = 1 1/2” SAE 24 Port-Threaded

Page 108: High Pressure Filters - HYDAC Technology · PDF fileF1 HIGH RESSURE FILTERS PN#02081318 / 03.16 / FIL1505-1696 High Pressure Filters 3000-6000 psi Robust carbon steel/ductile iron

F108

HIGH PRESSURE FILTERS

PN#02081318 / 03.16 / FIL1505-1696

Model A B C D E SAE O-Ring Port F G H J

TorqueAlu. Steel

CP-SAE 15 1.00/25.4 0.41/10.4 1.75/44.5 0.74/18.8 -10 (7/8-14) 2.41/61.2 1.12/28.4 min 1.87/47.5 max 0.266/6.8 0.781/19.8 min

0.814/20.7 max65

ft-lb85

ft-lb

CP-SAE 40 1.5/38.1 0.5/12.7 2.50/63.5 1.00/25.4 -16 (1 5/16-12) 3.34/84.8 1.49/37.8 min 2.53/64.3 max 0.531/13.5 1.140/29.0 min

1.1875/30.1 max150 ft-lb

200 ft-lb

CP-SAE 120 2.13/54.1 0.65/16.5 4.00/101.6 1.50/38.1 -24 (1 7/8-12) 5.01/127.3 1.92/48.8 min 3.81/96.8 max 0.875/22.2 1.750/44.5 min

1.803/45.8 max230 ft-lb

305 ft-lb

Dimensions CP-SAE

G

F

H

H

J0.030 Max Radius0.076Or Chamfer

Manifold FilterCavity Configuration

F

B

A

A

A

C

DOUTLET PORT

FilterElement (10 MicronWire Cloth Standard)

50 P.S.I.D.Bypass Valve(Initial Cracking)

BypassValve Assembly

INLET PORT

Size 15, 40, 120

Weight (lbs.) 1.5