i-ACCURATE_GB_07-2011 High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kW

Upload: truongdung

Post on 07-Jun-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

i-A

CC

UR

AT

E_G

B_0

7-2

01

1

High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kW

2 l 3

Data Center energy consumption

Cooling IT load

Coming form 40 years experience in air conditioning and

process cooling, i-ACCURATE is the ultimate solution for

technical rooms and data centres cooling:

From Climaveneta’s experience i-ACCURATE high precision air conditioners, available both as direct expansion andfree-cooling versions are the most efficientand reliable solution on the market.

Precise temperature

and humidity control

Complex IT centres require to keep temperature and humidity

within very strict parameters. This is particularly difficult due to

extremely variable thermal loads, that require very high cooling

capacity at full load, in order to avoid to compromise the correct

operation of the IT machines when they are more necessary.

The massive use of the new inverter technology on HPAC units

for technical rooms, makes possible to keep ambient

temperature and humidity constant even with very strong loads

variations, preventing dangerous temperature variations, almost

unavoidable with traditional ON/OFF compressor driven units.

High efficiency at partial loads

Most energy consumed by modern data centres is due to ambient

cooling. In more and more cases the cost due to cooling are

higher than those caused by data exchange. In systems

characterized by H24 operations, also the slightest compromise

concerning efficiency has dramatic implications in the operating

costs of the whole data centre. Hence it is crucial that the air

conditioning system of the centre works effectively also at part

loads, which are the most frequent operating condition, in order to

reduce the overall operating cost. i-ACCURATE strong point is

exactly efficiency at part loads. Thanks to the adoption of inverter

DC brushless compressors up to 30kW and inverter AC for lager

capacities, these units can reduce by 50% consumptions at part

load, if compared to a traditional ON/OFF compressor. This is

made possible also thanks to the advantages of variable air flow

enabled by last generation EC fans.

Versatility

The many types of structures used as technical areas and the

need to optimize their dimensions, require flexible solutions,

that can adapt to any room, always granting perfect control

and highest efficiency.

This means complete flexibility, both as concerns capacities

(from 6 to 150 kW Inverter), as well as configuration and

system with 5 different cooling solutions, including

FREECOOLING with R410A.

4 l 5

-15%

-15%

-25%

-25%

-10%

-10%

Plug

-in

(AC)

EC (D

C)

EC-N

ewge

nera

tion

(DC)

Annual power consumption

Constant speed

In case of low Hz Operation

AC Inverter DC Inverter

100%

55%

30%

Max

70%

Max

70%

Efficiency, versatility and reliability. These are the strong points that make i-ACCURATE a point of reference in high precision air conditioning. Advantages that come from distinctive technological choices in every aspect of this units.

Inverter

technology

The inverter driven compressor, though the variable frequency, modulates the power capacity provided, hence enabling to optimize the performances at part load, increasing efficiency.Moreover a larger capacity can be reached at full load, thus ensuring that the required temperature will be reached in a shorter time. Afterwards temperature variations can be easily controlled with minimized energy consumption, because once the set is reached, the compressor works at part load, reducing energy consumption and effectively maintaining the desired conditions.

In this respect i-ACCURATE represents the ultimate solution in high precision air conditioning, with the most updated compressors, both DC inverter brushless, for units from 7 to 30 kW and Inverter AC for larger capacities. Both solutions allow to perfectly adapt the unit’s performance to the real requirements of the building even at part load, which represent more than 75% of the operating time of the system. This ensures an energy saving up to 50% higher than solutions based on traditional ON/OFF compressors.

NEW GENERATION

EC fans

The high efficiency EC fan reduces both noise levels as well as energy consumption, and assures a variable air flow at part loads, optimizing the operating costs of the unit.

Main features

Further noise level reduction 4-5 dB(A) Further absorbed power reduction by 15%

An advanced logic simultaneously manages fans and inverter compressors modulation, with savings at part loads up to 50%.

EC fans

also in the remote condensers

The use of EC technology even on the remote condenser fan assures a further average reduction of noise levels by 10%, together with a strong reduction of energy consumption by 45% compared with traditional condensers with AC technology.

Intelligent

Control

i-ACCURATE, has an intelligent regulation, that allows the complete control of all the unit’s parameters in any condition.

i-ACCURATE control is completely open and can be set according to the specific needs of the customer, either on site or in advance when the unit is produced.

Electronic

thermostatic valve

The electronic valve is used in a very peculiar way in order to guarantee optimum operating conditions at the evaporator.

The INVERTER units come with electronic expansion valves as standard. These valves have a much wider modulation capacity; it stands out for its quality of control and for its capacity to quickly reach and maintain the operating stability of the unit and joined with INVERTER compressor technology allows a quick fluctuation-free regulation, and therefore a highly accurate adjustment to the swings of load and ambient conditions.

Types of cooling

Airflow configuration

OVERThe versions called OVER with air outflow from the top generally have the air intake at the front, rear or bottom of the unit, according to customer choice, and the outflow from the top is along ducts behind suspended ceilings or front delivery plenums.

UNDERThe versions called UNDER with air outflow under the floor have the air intake on the top of the unit taking air directly from the environment or through intake ducts or plenums.

OVER unit with front intake and delivery plenum

OVER unit with front intakeand top delivery

OVER unit with underfloor intakeand top delivery

UNDER unit with top intakeand front delivery plenum

UNDER unit with top intakeand undefloor delivery

OVER unit with rear intake and top delivery

6 l 7

i-AXO/i-AXU

DIRECT EXPANSION AIR COOLED, with INVERTER compressor

Refrigerant for heat transfer is used in these direct expansion units. The air in the room is therefore treated in the evaporating coil containing the refrigerant. The condensation heat is dispersed to a fresh air condenser that with speed control for condensing control, optimise the condensation pressure even in adverse temperature conditions.

Units provided per standard with EC inverter fans who represents today the best solution for energy saving.

i-AWO/i-AWU

DIRECT EXPANSION WATER COOLED, with INVERTER compressor

Refrigerant for heat transfer is used in these direct expansion units. The air in the room is therefore treated in the evaporating coil containing the refrigerant. The condensation heat is dispersed in an internal plate-type exchanger connected in turn to a water circuit. The water of condensation may come from a well, local water mains or closed circuits such as cooling towers or dry coolers.Units provided per standard with EC inverter fans who represents today the best solution for energy saving.

NB: for negative External T values antifreeze fluids must be used to protect the system

i-ATO/i-ATU Dual Fluid Inverter

These units are per standard provided with a dual cooling systems who never work simultaneously.A PRIMARY circuit, made by a chilled water circuit (CW) generally connected to an external chiller, plus a SECONDARY circuit in direct expansion (DX) water cooled, who is considered as BACK-UP.Such units are particulary indicated anywhere RELIABILITY, SAFETY and REDUNDANCY are required.

Units provided per standard with EC inverter fans who represents today the best solution for energy saving.

i-AFO/i-AFU Free Cooling Inverter

These units are per standard provided with a dual cooling systems who are often working simulateusly along the year.A PRIMARY direct expansion circuit (DX) plus a SECONDARY chilled water circuit (CW) generally connected to an external dry cooler who is considered as "support" to the primary one.Such units are particulary indicated anywhere EFFICIENCY & ENERGY SAVING are required.

Units provided per standard with EC inverter fans who represents today the best solution for energy saving.

i-ADO/i-ADU Dual Fluid Inverter

These units are per standard provided with a dual cooling systems who never work simultaneously.A PRIMARY circuit, made by a chilled water circuit (CW) generally connected to an external chiller, plus a SECONDARY circuit in direct expansion (DX) air cooled, who is considered as BACK-UP. Such units are particulary indicated anywhere RELIABILITY, SAFETY and REDUNDANCY are required.

Units provided per standard with EC inverter fans who represents today the best solution for energy saving.

All-round flexibility seen as a service offered for any type of system.i-ACCURATE comes with capacities from 6 to 150 kW in the direct expansion version with air cooling (i-AXO / i-AXU) and water cooling(i-AWO / i-AWU) and capacities from 11 to 130 kW in version dual fluid(i-ADO / i-ADU and i-ATO / i-ATU) and free cooling (i-AFO / i-AFU).

Note

(1) Indoor conditions :24°C-50% Condensing temp.45°C - ESP 20Pa

(2) Measured at 1,5 m height, 2 m in front of the unit in free field

i-ACCURATE range unit with R410A &

inverter driven scroll compressor from

6 to 150 kW, air cooled.

COOLING

r HFCR-410A

SCROLL

ACCURATE INVERTER i-AX

Frame

Power supply V/Ph/Hz

Refrigerant

n° Circuits/Compressors

PERFORMANCES

High Speed

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

EER

Low speed

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

Booster (not continuative functioning)

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

VENTILATION

Nominal air flow volume m3/h

N° EC Fans

Fan absorbed power kW

Sound pressure level (2) dB(A)

HUMIDIFIER

Capacity kg/h

Absorbed power kW

ELECTRICAL HEATERS

Steps

Absorbed power kW

DIMENSIONS

L mm

P mm

H mm

8 l 9

18 29 50 70 90 130 150

F2 F3 F4 F5 F6 F7 F7

400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50

R410A R410A R410A R410A R410A R410A R410A

1/1 1/1 1/1 2/2 2/2 2/3 2/3

16,60 28,07 53,14 68,40 84,68 133,9 149,8

16,60 28,07 50,30 67,30 84,68 115,3 123,2

1,00 1,00 0,95 0,98 1,00 0,86 0,82

4,09 7,14 13,92 16,47 21,03 32,05 36,2

3,65 3,24 3,12 3,25 3,12 3,44 3,48

6,27 10,62 23,68 22,06 22,70 23,1 23,1

6,27 10,62 23,68 22,06 22,70 23,1 23,1

1,00 1,00 1,00 1,00 1,00 1 1

1,24 1,96 4,85 4,82 4,83 5,08 5,08

20,42 34,77 56,52 85,31 93,47 - -

18,44 31,10 51,30 74,60 89,77 - -

0,90 0,89 0,91 0,87 0,96 - -

5,66 8,00 15,24 22,49 24,49 - -

4900 8000 13500 19000 25000 30000 30000

2 1 2 3 3 3 3

0,47 1,51 3,13 4,57 6,1 6,9 6,9

53 60 64 67 67 69 69

5 5 5 8 8 15 15

3,75 3,75 3,75 6 6 11,25 11,25

3 3 3 3 3 3 3

8 9 15 18 18 24 24

1000 1000 1550 2100 2650 2650 2650

500 790 790 790 790 890 890

1980 1980 1980 1980 1980 2195 2195

Note

(1) Indoor conditions :24°C-50% Water 30- 35°C - ESP 20Pa (2) Measured at 1,5 m height, 2 m in front of the unit in free field

i-ACCURATE range unit with R410A

& inverter driven scroll compressor

from 6 to 150 kW, water cooled.

COOLING

r HFCR-410A

SCROLL

Note

(1) Indoor conditions : 24°C-50%, Condensing temp. 45°C - ESP 20Pa (2) Indoor conditions : 24°C-50%, Water 7-12°C - ESP 20Pa(5) Measured at 1,5 m height in front of the unit in free field

i-ACCURATE INVERTER i-AD

Frame Power supply V/Ph/HzRefrigerant

n° Circuits/CompressorsPERFOMANCES High speed Total cooling capacity (1) kWSensible cooling capacity (1) kWSHR (1)Total compressors absorbed power kWEER Low speed Total cooling capacity (1) kWSensible cooling capacity (1) kWSHR (1)Total compressors absorbed power kWBooster (not continuative functioning) Total cooling capacity (1) kWSensible cooling capacity (1) kWSHR (1)Total compressors absorbed power kWPERFOMANCES CW

Total cooling capacity (2) kWSensible cooling capacity (2) kWSHR (1)Water flow (2) l/hPressure drop kPaVENTILATION

Nominal ai flow volume m3/hN° EC Fans Fan absorbed power kWSound pressure level (5) dB(A)

HUMIDIFIER

Capacity kg/h

Absorbed power kWELECTRICAL HEATERS

Steps Absorbed power kWDIMENSIONS L mmP mmH mm

Close control unit dual fluid, air cooled direct expansion.

i-ACCURATE range unit with R410A & inverter driven

scroll compressor from 11 to 130 kW, air cooled dual fluid.

COOLING

r HFCR-410A

SCROLL

i-ACCURATE INVERTER i-AW

Frame

Power supply V/Ph/Hz

Refrigerant

n° Circuits/Compressors

PERFORMANCES

High Speed

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

EER

Low speed

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

Booster (not continuative functioning)

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

PLATES CONDENSER

N°Water flow l/h

Pressure drop kPa

VENTILATION

Nominal air flow volume m3/h

N° EC Fans

Fan absorbed power kW

Sound pressure level (2) dB(A)

HUMIDIFIER

Capacity kg/h

Absorbed power kW

ELECTRICAL HEATERS

Steps

Absorbed power kW

DIMENSIONS

L mm

P mm

H mm

10 l 11

18 29 50 70 90 130 150

F2 F3 F4 F5 F6 F7 F7

400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50

R410A R410A R410A R410A R410A R410A R410A

1/1 1/1 1/1 2/2 2/2 2/3 2/3

17,4 29,3 55 72,3 91,5 140,6 156,8

17 28,6 50,8 69,5 89,8 118,1 126,4

0,98 0,98 0,92 0,96 0,98 0,84 0,81

3,68 6,38 13 14,5 19,6 29,1 33,04

4,19 3,71 3,41 3,79 3,56 3,91 3,93

7,27 12,3 25,7 23,6 25,4 25,7 25,7

7,27 12,3 25,7 23,6 25,4 25,7 25,7

1 1 1 1 1 1 1

0,96 1,43 3,83 3,99 3,92 3,94 3,94

21,69 35,3 58,07 88,03 100,09 - -

18,96 31,1 52,00 75,9 93,1 - -

0,87 0,88 0,90 0,86 0,93 - -

4,97 7,83 14,46 21,00 23,64 - -

1 2 2 1 1 1 1

3590 6090 11620 14790 18970 28740 32640

6 23 54 26 36 27 39

4900 8000 13500 19000 25000 30000 30000

2 1 2 3 3 3 3

0,47 1,51 3,13 4,57 6,1 6,9 6,9

53 60 64 67 67 69 69

5 5 5 8 8 15 15

3,75 3,75 3,75 6 6 11,25 11,25

3 3 3 3 3 3 3

8 9 15 18 18 24 24

1000 1000 1550 2100 2650 2650 2650

500 790 790 790 790 890 890

1980 1980 1980 1980 1980 2195 2195

29 50 70 90 130

F3 F4 F5 F6 F7 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A 1/1 1/1 2/2 2/2 2/3 27,5 51,5 67,4 89,6 122,6 27,5 49,5 66,6 85,1 107,9 1 0,96 0,99 0,95 0,88 6,83 14,1 16,8 21,8 31,7 3,19 2,89 3,04 3,20 3,18 11,3 21,3 19,4 21 22,4 11,3 21,3 18,2 21 22,4 1 1 0,94 1 1 2,05 4,9 4,88 4,95 5,07 32,54 54,47 76,6 99,1 - 30,15 50,78 70,6 89,4 - 0,93 0,93 0,92 0,90 - 9,21 14,41 20,2 25,4 - 29,5 51,4 67,6 91 125,7 27,6 47,5 64,5 85 98,5 0,94 0,92 0,95 0,93 0,78 5060 8820 11600 15610 21620 48 56 61 58 68 8000 13500 19000 24000 28000 1 2 3 3 3 1,78 3,69 5,38 6,24 6,9 60 64 67 67 69 5 5 8 8 15 3,75 3,75 6 6 11,25 3 3 3 3 3 9 15 18 18 24 1000 1550 2100 2650 2650 790 790 790 790 890 1980 1980 1980 1980 2195

Note

(1) Indoor conditions: 24°C-50%, Water 30-35°C - ESP 20Pa(2) Water IN 10°C water flow as DX mode - ESP 20Pa(5) Measured at 1,5 m height in front of the unit in free field

i-ACCURATE INVERTER i-AF

Frame

Refrigerant

PERFOMANCES

Total cooling capacity (1) kW

SHR (1)

EER

Total cooling capacity (1) kW

SHR (1)

Booster (not continuative functioning)

Sensible cooling capacity (1) kW

Total compressors absorbed power kW

Quantity

Pressure drop DX functioning kPa

Total cooling capacity (2) kW

SHR (1)

VENTILATION

N° EC Fans

Sound pressure level (5) dB(A)

Capacity kg/h

ELECTRICAL HEATERS

Absorbed power kW

L mm

H mm

Close control unit dual fluid, air cooled direct

expansion. i-ACCURATE range unit with

R410A & inverter driven scroll compressor

from 11 to 130 kW, free cooling source.

COOLING

r HFC

SCROLL

Close control unit dual fluid, air cooled direct expansion

i-ACCURATE range unit with R410A & inverter driven scroll

compressor from 11 to 130 kW, water cooled, dual fluid.

Note

(1) Indoor conditions: 24°C-50%, Water 30-35°C - ESP 20Pa (2) Indoor conditions: 24°C-50%, Water 7-12°C - ESP 20Pa (5) Measured at 1,5 m height in front of the unit in free field

i-ACCURATE INVERTER i-AT

FramePower supply V/Ph/HzRefrigerantn° Circuits/CompressorsPERFOMANCES

High speed

Total cooling capacity (1) kWSensible cooling capacity (1) kWSHR (1)Total compressors absorbed power kWEERLow speed

Total cooling capacity (1) kWSensible cooling capacity (1) kWSHR (1)Total compressors absorbed power kWBooster (not continuative functioning) Total cooling capacity (1) kWSensible cooling capacity (1) kWSHR (1)Total compressors absorbed power kWWATER CONDENSER PLATE QuantityCondensing water flow (1) l/hPressure drop DX functioning kPaPERFOMANCES CW

Total cooling capacity (2) kWSensible cooling capacity (2) kWSHR (1)Water flow (2) l/hPressure drop kPaVENTILATION

Nominal air flow volume m3/hN° EC FansFan absorbed power kW Sound pressure level (5) dB(A)HUMIDIFIER

Capacity kg/hAbsorbed power kWELECTRICAL HEATERS

StepsAbsorbed power kWDIMENSIONS

L mmP mmH mm

COOLING

r HFCR-410A

SCROLL

12 l 13

29 50 70 90 130

F3 F4 F5 F6 F7 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A 1/1 1/1 2/2 2/2 2/3 28,6 53,5 71,4 92,9 128,6 28,4 50,3 68,5 86,2 110,4 0,99 0,94 0,96 0,93 0,86 6,15 13,1 14,7 20,2 28,6 3,61 3,19 3,56 3,51 3,62 12,4 23,2 21,2 22,9 24,5 12,4 23,2 18,9 21,7 24,5 1 1 0,89 0,95 1 1,49 3,79 3,82 3,88 3,91 33,3 56,26 80,3 102,2 - 30,47 51,42 72,0 90,2 - 0,92 0,91 0,90 0,88 - 8,72 14,4 18,3 23,9 - 1 1 2 1 1 6010 11520 15500 20360 27050 35 51 36 64 74 24,3 43,5 57,7 78,1 104,5 24,3 43,5 57,7 78,1 94,1 1 1 1 1 0,90 65 91 101 94 132 8000 13500 19000 24000 28000 1 2 3 3 3 1,78 3,69 5,38 6,24 6,9 60 64 67 67 67 5 5 8 8 15 3,75 3,75 6 6 11,25 3 3 3 3 3 9 15 18 18 24 1000 1550 2100 2650 2650 790 790 790 790 890 1980 1980 1980 1980 2195

29 50 70 90 130

F3 F4 F5 F6 F7 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A 1/1 1/1 2/2 2/2 2/3 28,6 53,5 71,4 92,9 128,6 28,4 50,3 68,5 86,2 110,4 0,99 0,94 0,96 0,92 0,86 6,15 13,1 14,7 20,2 28,6 3,61 3,19 3,56 3,51 3,62 12,4 23,2 21,2 22,9 24,5 12,4 23,2 18,9 21,7 24,5 1 1 0,89 0,94 1 1,49 3,79 3,82 3,88 3,91 33,3 56,26 80,3 102,2 - 30,47 51,42 72,0 90,2 - 0,92 0,91 0,90 0,88 - 8,72 14,4 18,3 23,9 - 1 1 2 1 1 6010 11520 15500 20360 27050 22 30 27 38 28 29,5 51,4 67,6 91 125,7 27,6 47,5 64,5 85 98,5 0,93 0,92 0,95 0,93 0,78 5060 8820 11600 15610 21620 48 56 61 58 68 8000 13500 19000 24000 28000 1 2 3 3 3 1,78 3,69 5,38 6,24 6,9 60 64 67 67 69 5 5 8 8 15 3,75 3,75 6 6 11,25 3 3 3 3 3 9 15 18 18 24 1000 1550 2100 2650 2650 790 790 790 790 890 1980 1980 1980 1980 2195

14 l 15

All around the world, in the most important data centres, and in all projects where efficiency, quality and reliability are a must, i-ACCURATE high precision air conditioners are the best guarantee

IBM Mompellier Head officesOver 24 units Accurate in different installations, over

400kW total capacity, provided by:

DX aircooled units, Accurate AXU 50, Accurate AXU 88,

Accurate AXU 40, Accurate AXU 55, Accurate AXO 7,

Accurate AXO 10

Lattelkom Largest Telecommunications

and IT network in LatviaOver Accurate 24 units in different installations,

over 400kW total capacity, provided by: DX aircooled units,

Accurate AXU 50, Accurate AXU 88, Accurate AXU 40, Accurate

AXU 55, Accurate AXO 7, Accurate AXO 10

SuvidhaIndia

Dual Fluid units, 8 Accurate ADU60BE,

4 Accurate ADU 30 BE

Túneles M-30Spain

DX aircooled units,

Accurate DXU 20 / 10

Eads - CasaSpain

DX aircooled units,

Accurate DXO 18

Telefonica CileChile

Over 20 DX aircooled units

among which, Accurate AXO 55,

Accurate AXU 60, Accurate AXO 20,

Accurate AXO 07, Accurate AXU 50

AlphabankRomania

8 Dual fluid units, Accurate ATO 77BE,

Accurate ATO 60BE

GazpromRussia

DX aircooled units,

Accurate DLU 077BE,

Accurate DLU 039ME

Buygues TelecomFrance

DX aircooled units,

Accurate ACU 25 EC,

Accurate ACU 70 EC, Accurate ACU 70 EC,

Accurate ACU 90 EC, Accurate ADU 20,

Accurate ADU 77

Caffemacherreihe

Nr. 16 OfficesHamburg - Germany

DX watercooled units,

Accurate AFU 50

Verwaltung der AOK

DeutschlandBerlin - Germany

DX watercooled units,

Accurate AWU 26

HispasatSpain

DX aircooled units,

Accurate DXU 39 / 29 / 20 / 18

Sir Francis BaconBritish Philosopher (1561 - 1626)