hi-lume a-series driver overview forward phase control · pdf filehi-lume ® a-series...
TRANSCRIPT
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 1 08.07.2015
Hi-lume® A-Series Driver Overview Forward Phase Control
The Hi-lume® A-Series Driver is a high-performance LED driver that provides smooth, continuous 1% dimming for constant current LED modules.
Features• Continuous, flicker-free dimming from 100% to 1%.• Guaranteed compatibility with selected HomeWorks®,
GRAFIK Eye® QS, and GRAFIK SystemsTM dimmers. Please see the chart “Compatible Controls” at the end of this document or contact Lutron Asuka for details regarding compatible controls.
• 100% performance-tested at factory.• A rated lifetime of 50 000 hours @ tc = 65 °C.• PSE Certified.• RoHS Compliant.• Pulse width modulation (PWM) or constant current
reduction (CCR) dimming methods available. See Application Note #360 for details.
• For more information please go to: www.lutron.com/HilumeLED
Hi-lume® A-Series, case type K76 mm W × 25 mm H × 124 mm L
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 2 08.07.2015
Specifications
Performance• Dimming Range: 100% to 1%• Operating Voltage: 100 V~ at 50/60 Hz (Forward
Phase Control)• A rated lifetime of 50,000 hours @ tc = 149 °F (65 °C).
– For rated warranty, tc not to exceed the maximum rated temperatures. 1
• Patented thermal foldback protection.• LEDs turn on to any dimmed level without going to full
brightness.• Nonvolatile memory restores all driver settings after
power failure.• Power Factor: > 0.90 at 40 W• Total Harmonic Distortion (THD): < 20% at 40 W• Inrush Current: < 2 A• Inrush Current Limiting Circuitry: eliminates circuit
breaker tripping, switch arcing and relay failure.• Open circuit protected• Short circuit protected• Turn-on time: ≤ 1.5 seconds 2
• PWM Dimming Frequency: 550 Hz
Environmental• Sound Rating: Class A.• Relative Humidity: Maximum 90% non-condensing.• Minimum operating ambient temperature (ta) = 0 °C.
Standards• Meets IEEE C62.41 category A surge protection
standards up to and including 4 kV.• Manufacturing facilities employ ESD reduction
practices that comply with the requirements of ANSI/ESD S20.20.
• Lutron® Quality Systems registered to ISO 9001.2008.• H PSE certified.
Driver Wiring and Mounting• Driver is grounded by a mounting screw to the
grounded fixture or by terminal connection.• Terminal blocks on the driver accept one solid wire
per terminal from Ø 1.024 mm (18 AWG) to Ø 1.29 mm (16 AWG).
• Fixture must be grounded in accordance with local and national electrical codes.
• Do not use more than 1 wire per connector terminal. Connector terminals are not rated for daisy-chain wiring.
• Maximum driver-to-LED light engine wire length for Constant Current Drivers:
Wire Gauge ØMaximum Lead Length
200 mA to 700 mA 710 mA to 1.50 A1.024 mm (18 AWG) 9 m 4.5 m1.29 mm (16 AWG) 10.5 m 7.5 m1.63 mm (14 AWG) 15 m 12 m2.05 mm (12 AWG) 30 m 18 m
Note: For wire gauges larger than Ø 1.29 mm (16 AWG), use external connector for connection with driver
1 Installer is responsible for ensuring that the driver case temperature does not exceed the maximum rated temperature.2 Models available with turn-on time ≤ 1 second.
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 3 08.07.2015
How to Build a Model Number: Hi-lume® A-Series
Case Style:S = Studded N = Non-Studded
Driver Output:C = Constant current driver with pulse width modulation (PWM) dimmingA = Constant current driver with constant current reduction (CCR) dimming
Current Level (for Constant Current):020 = 0.20 A; 021 = 0.21 A … 100 = 1.00 A … 150 = 1.50 A
Example: LTEA3D11KN-JA100For further assistance selecting your model number, contact Lutron Asuka at 03.5575.8411 (phone), 0120.083.417 (freephone), or [email protected]
LED Driver Output Range (see the following pages for more detail):Constant CurrentG = 0.20 A – 0.70 A 8 V – 20 VH = 0.20 A – 0.70 A 15 V – 38 VI = 0.71 A – 1.05 A 8 V – 20 VJ = 0.71 A – 1.05 A 15 V – 38 VK = 1.06 A – 1.50 A 8 V – 20 VL = 1.06 A – 1.50 A 15 V – 38 V
LTEA3D11K — – — — ———
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 4 08.07.2015
“G” Output Range, Current Driver Models
Driver Type Output Dimming Method Output Voltage Output Current Output Power Standards RecognitionConstant Current Driver (Class 2)
Pulse Width Modulation (PWM) 8 – 20 V 0.20 – 0.70 A 2 – 14 W HConstant Current Reduction (CCR)
Typical Performance Specifications:
Parameter Value Test ConditionsInput Current 186 mA ta = 25 °C,
0.70 A 14 W load, Max. Light Output, K enclosure 100 V~ without a control
Power Factor 0.99THD < 20% for loads greater than 10 WDriver Efficiency 76%
Effi
cien
cy (%
)
80
75
70
65
60
55
50
45
40
Driver Efficiency vs. Output Power at 100 V~
2 4 6 8 10 12 14Output Power (W)
0.20 A
0.35 A
0.50 A
0.70 A
Out
put V
olta
ge (V
)
60
50
40
30
20
10
0
Output Voltage vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
G
Out
put P
ower
(W)
40
35
30
25
20
15
10
5
0
Output Power vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
G
20 V Max.
8 V Min.
0.2
32
3
1.50.2
38
8
1.5
Current Driver Operation Range:
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 5 08.07.2015
“H” Output Range, Current Driver Models
Driver Type Output Dimming Method Output Voltage Output Current Output Power Standards RecognitionConstant Current Driver (Class 2)
Pulse Width Modulation (PWM) 15 – 38 V PWM0.20 – 0.70 A 3 – 26 W HConstant Current Reduction (CCR) 15 – 38 V-
Typical Performance Specifications:
Parameter Value Test ConditionsInput Current 325 mA ta = 25 °C,
0.70 A 26 W load, Max. Light Output, K enclosure 100 V~ without a control
Power Factor 0.99THD < 20% for loads greater than 10 WDriver Efficiency 80%
Effi
cien
cy (%
)
85
80
75
70
65
60
55
50
Driver Efficiency vs. Output Power at 100 V~
0 5 10 15 20 25 30Output Power (W)
0.20 A
0.45 A0.70 A
Out
put V
olta
ge (V
)
60
50
40
30
20
10
0
Output Voltage vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
H
Out
put P
ower
(W)
40
35
30
25
20
15
10
5
0
Output Power vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
H
38 V Max.
15 V Min.
0.2
32
3
1.50.2
38
8
1.5
Current Driver Operation Range:
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 6 08.07.2015
“I” Output Range, Current Driver Models
Driver Type Output Dimming Method Output Voltage Output Current Output Power Standards RecognitionConstant Current Driver (Class 2)
Pulse Width Modulation (PWM) 8 – 20 V 0.71 – 1.05 A 6 – 21 W HConstant Current Reduction (CCR)
Typical Performance Specifications:
Parameter Value Test ConditionsInput Current 268 mA ta = 25 °C,
1.05 A 21 W load, Max. Light Output, K enclosure 100 V~ without a control
Power Factor 0.99THD < 20% for loads greater than 10 WDriver Efficiency 78%
Effi
cien
cy (%
)
80
75
70
65
60
55
50
45
40
Driver Efficiency vs. Output Power at 100 V~
0 9 12 15 18 21 Output Power (W)
0.71 A1.05 A
Out
put V
olta
ge (V
)
60
50
40
30
20
10
0
Output Voltage vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
I
Out
put P
ower
(W)
40
35
30
25
20
15
10
5
0
Output Power vs. Output Current
0 0.35 0.71 1.05 1.4 1.75 2.1Output Current (A)
I
20 V Max.
8 V Min.
0.2
32
3
1.50.2
38
8
1.5
Current Driver Operation Range:
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 7 08.07.2015
“J” Output Range, Current Driver Models
Driver Type Output Dimming Method Output Voltage Output Current Output Power Standards RecognitionConstant Current Driver (Class 2)
Pulse Width Modulation (PWM) 15 – 38 V PWM0.71 – 1.05 A 11 – 32 W HConstant Current Reduction (CCR) 15 – 38 V-
Typical Performance Specifications:
Parameter Value Test ConditionsInput Current 400 mA ta = 25 °C,
1.05 A 32 W load, Max. Light Output, K enclosure 100 V~ without a control
Power Factor 0.99THD < 20%Driver Efficiency 80%
Effi
cien
cy (%
)
90
85
80
75
70
65
60
Driver Efficiency vs. Output Power at 100 V~
10 15 20 25 30 35 Output Power (W)
0.71 A 0.90 A
1.05 A
Out
put V
olta
ge (V
)
60
50
40
30
20
10
0
Output Voltage vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
J
Out
put P
ower
(W)
40
35
30
25
20
15
10
5
0
Output Power vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
J
38 V Max.
15 V Min.
32 V Max.
0.2
32
3
1.50.2
38
8
1.5
Current Driver Operation Range:
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 8 08.07.2015
“K” Output Range, Current Driver Models
Driver Type Output Dimming Method Output Voltage Output Current Output Power Standards RecognitionConstant Current Driver (Class 2)
Pulse Width Modulation (PWM) 8 – 20 V 1.06 – 1.50 A 9 – 30 W HConstant Current Reduction (CCR)
Typical Performance Specifications:
Parameter Value Test ConditionsInput Current 392 mA ta = 25 °C,
1.50 A 30 W load, Max. Light Output, K enclosure 100 V~ without a control
Power Factor 0.99THD < 20% for loads greater than 10 WDriver Efficiency 77%
Effi
cien
cy (%
)
80
75
70
65
60
55
50
45
40
Driver Efficiency vs. Output Power at 100 V~
0 11 13 15 17 19 21 23 25 27 29 Output Power (W)
1.06 A 1.20 A1.50 A
Out
put V
olta
ge (V
)
60
50
40
30
20
10
0
Output Voltage vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
K
Out
put P
ower
(W)
40
35
30
25
20
15
10
5
0
Output Power vs. Output Current
0 0.35 0.71 1.05 1.4 1.75 2.1Output Current (A)
K
20 V Max.
8 V Min.
0.2
32
3
1.50.2
38
8
1.5
Current Driver Operation Range:
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 9 08.07.2015
“L” Output Range, Current Driver Models
Driver Type Output Dimming Method Output Voltage Output Current Output Power Standards RecognitionConstant Current Driver (Class 2)
Pulse Width Modulation (PWM) 15 – 38 V PWM1.06 – 1.50 A 16 – 32 W HConstant Current Reduction (CCR) 15 – 38 V-
Typical Performance Specifications:
Parameter Value Test ConditionsInput Current 420 mA ta = 25 °C,
1.50 A 32 W load, Max. Light Output, K enclosure 100 V~ without a control
Power Factor 0.99THD < 20%Driver Efficiency 75%
Effi
cien
cy (%
)
90
85
80
75
70
65
60
Driver Efficiency vs. Output Power at 100 V~
15 17 19 21 23 25 27 29 31 33Output Power (W)
1.06 A1.20 A 1.50 A
Out
put V
olta
ge (V
)
60
50
40
30
20
10
0
Output Voltage vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 2.1Output Current (A)
L Out
put P
ower
(W)
40
35
30
25
20
15
10
5
0
Output Power vs. Output Current
0 0.35 0.7 1.05 1.4 1.75 Output Current (A)
L
15 V Min.
32 V Max.
0.2
32
3
1.50.2
38
8
1.5
Current Driver Operation Range:
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 10 08.07.2015
K Case: Case Dimensions
K Case: Connector Location Dimensions
A 107 mmB 25 mmC 76 mmD 124 mmE 117 mm (mounting center)
F 36 mmG 51 mmH* 28 mmI* 51 mmJ* 41 mm
K* 8.3 mmL 16.5 mmM 19 mmN 44 mmO 34 mm
* Applies to studded K case only.
P 19 mmQ 8 mmR* 7 mm
A
C
ED
J*
B
F
G
H*
I*
PO
N
Q
K*
K*
L
M
Q
R*
L
8 – 32 Threaded Studs*
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 11 08.07.2015
K Case: Side Entry Connector Location Dimensions (Non-Studded)
S
U
V
T
S 35 mmT 16 mmU 22 mmV 39 mm
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 12 08.07.2015
Wiring Diagram for Forward Phase Control
1 Fixture and driver case must be grounded. 2 For maximum driver–to–LED light engine wire length, see chart in Driver Wiring and Mounting section.
Note: Colors shown correspond to terminal blocks on driver.
To Forward Phase Dimming Control
Dimmed Hot (Black)
Ground1 (Green)
Ground1Neutral (White) –V2 (Black)
Hi-lume® A-Series
+V2 (Red)
LED light engine
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 13 08.07.2015
Compatible Controls
• Guaranteed performance specifications with the controls listed in the chart below.• For assistance selecting controls, contact Lutron Asuka at 03.6866.8444 (phone), 0120.083.417 (freephone), or
Product Part Number Fixtures per Control (100 V~ only)
Measured Light Output Range
HomeWorks® 500 W dimmer HWD-5ND-JA 1 – 8 100% – 1%GRAFIK Eye® QS1 QSGR-3PJA
QSGR-4PJAQSGR-6PJA
2 – 10 (per output) 26 total per unit
100% – 1%
GRAFIK Eye® 30002 GRX-3102-x-JA-xxGRX-3103-x-JA-xxGRX-3104-x-JA-xxGRX-3106-x-JA-xxGRX-3502-x-JA-xxGRX-3503-x-JA-xxGRX-3504-x-JA-xxGRX-3506-x-JA-xx
2 – 10 (per output) 26 total per unit
100% – 1%
RPM-4U Module3 (LCP Combo, GRAFIK SystemsTM)
LP-RPM-4U-120 2 – 26 (per output) 26 total per module
100% – 1%
RPM-4A Module3 (LCP Combo, GRAFIK SystemsTM)
LP-RPM-4A-120 1 – 13 (per output) 26 total per module
100% – 1%
GRAFIK SystemsTM Dimming Panels3 GP-4-2L-JAJDPxx-xxxxx
1 – 26 (per output) 100% – 1%
1 Set load type to “Fluorescent Module”2 Set load type to “GRX-FDBI or GRX-TVI”3 Set load type to “ 2-1”
Hi-lumeTM A-Series LTE – Japan
® SPECIF ICAT ION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LED Dimming Driver Architectural Dimming
369677e 14 08.07.2015
Electricians and Contractors
Driver LeadsMaximum driver-to-LED light engine wire length for Constant Current Drivers:
Wire Gauge ØMaximum Lead Length
200 mA to 700 mA 710 mA to 1.50 A1.024 mm (18 AWG) 9 m 4.5 m1.29 mm (16 AWG) 10.5 m 7.5 m1.63 mm (14 AWG) 15 m 12 m2.05 mm (12 AWG) 30 m 18 m
Note: For wire gauges larger than Ø 1.29 mm (16 AWG), use external connector for connection with driver
Wiring and Grounding• Driver must be grounded.• Drivers must be installed per national and local
electrical codes.
LED Light Engine ReplacementThe LED light engine can be changed while the driver is installed and powered.
Maximum Driver Operating TemperatureFor 50,000 hour lifetime, driver case temperature (tc)must not exceed 65 °C.
Facilities Managers
SERVICE
WarrantyFor warranty information, please contact Lutron Asuka.
Replacement PartsWhen ordering Lutron® replacement parts please provide the full model number. Contact Lutron Asuka if you have any questions.
Further InformationFor further information, please visit us at http://www.lutron.jp.You may contact Lutron Asuka at: 03.6866.8444 (phone), 0120.083.417 (freephone) or [email protected]