Page 1: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

HeatingTechnical Data

ERGA04-08DVA

Page 2: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water
Page 3: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Heating • ERGA04-08DVA 1

• Outdoor Unit • ERGA04-08DVA

TABLE OF CONTENTSERGA04-08DVA

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

3 Combination table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

4 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Cooling Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Heating Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Certification Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

5 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

6 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

7 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

8 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

10 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

Page 4: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

1

2

1 Features

door Uni ting A04-08DVA kin Alth

Out Hea ERG Dai • Outdoor unit extracts heat from the outdoor air, even at -25°C

Guaranteed operation down

to -25°C

• Heating • ERGA04-08DVA

Page 5: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBH04D6V/ERGA04DVA EHBH08D6V/ERGA06DVA EHBH08D6V/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6.0 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98

Pdh kW 5.3 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.5 3.0

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79 85 87

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5.0 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 4.7 5.6 6.0

• Heating • ERGA04-08DVA 3

Page 6: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

4

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6.0 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.66

Pdh kW 5.5 6.1 7.5

PERd % 116 123 106

Tbiv °C -7 -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5.0 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5.2 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBH04D6V/ERGA04DVA EHBH08D6V/ERGA06DVA EHBH08D6V/ERGA08DVA

• Heating • ERGA04-08DVA

Page 7: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 6.0

Domestic hot water heating

Average climate ηwh (water heating efficiency) % -

Cold climate ηwh (water heating efficiency) % -

Warm climate ηwh (water heating efficiency) % -

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

COP 5.10 (1) / 3.65 (2) 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

Pump Nominal ESP unit Heating kPa 59.6 (1) / 58.6 (2) 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 12.3 (1) / 13.2 (2) 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBH04D6V/ERGA04DVA EHBH08D6V/ERGA06DVA EHBH08D6V/ERGA08DVA

• Heating • ERGA04-08DVA 5

Page 8: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

6

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBH08D9W/ERGA06DVA EHBH08D9W/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.25 3.27

Annual energy consumption

kWh 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.98

Pdh kW 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.16 3.18

Pdh kW 3.9 4.1

PERd % 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.49 4.54

Pdh kW 3.0

PERd % 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.43

Pdh kW 4.5

PERd % 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.5 3.0

Tbiv (bivalent temperature)

COPd 2.12 2.18

Pdh kW 6.1 6.4

PERd % 85 87

Tbiv °C -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 5,325 7,066

ηs (Seasonal space heating efficiency)

% 108 109

Prated at -22°C kW 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,858 1,983

ηs (Seasonal space heating efficiency)

% 158 159

Prated at 2°C kW 5.6 6.0

• Heating • ERGA04-08DVA

Page 9: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.47 4.56

Annual energy consumption

kWh 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.86 2.77

Pdh kW 6.0 7.0

PERd % 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.25 4.35

Pdh kW 3.9 4.2

PERd % 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.30 6.49

Pdh kW 3.2 3.3

PERd % 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.49 2.41

Pdh kW 6.0 6.9

PERd % 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 3.07 2.66

Pdh kW 6.1 7.5

PERd % 123 106

Tbiv °C -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,749 5,052

ηs (Seasonal space heating efficiency)

% 155 153

Prated at -22°C kW 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,276 1,437

ηs (Seasonal space heating efficiency)

% 248 257

Prated at 2°C kW 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBH08D9W/ERGA06DVA EHBH08D9W/ERGA08DVA

• Heating • ERGA04-08DVA 7

Page 10: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

8

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 9.0

Domestic hot water heating

Average climate ηwh (water heating efficiency) % -

Cold climate ηwh (water heating efficiency) % -

Warm climate ηwh (water heating efficiency) % -

Heating capacity Nom. kW 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

COP 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

Pump Nominal ESP unit Heating kPa 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBH08D9W/ERGA06DVA EHBH08D9W/ERGA08DVA

• Heating • ERGA04-08DVA

Page 11: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBX04D6V/ERGA04DVA EHBX08D6V/ERGA06DVA EHBX08D6V/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6.0 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98

Pdh kW 5.3 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.5 3.0

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79 85 87

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5.0 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 4.7 5.6 6.0

• Heating • ERGA04-08DVA 9

Page 12: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

10

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6.0 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.66

Pdh kW 5.5 6.1 7.5

PERd % 116 123 106

Tbiv °C -7 -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5.0 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5.2 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBX04D6V/ERGA04DVA EHBX08D6V/ERGA06DVA EHBX08D6V/ERGA08DVA

• Heating • ERGA04-08DVA

Page 13: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 6.0

Domestic hot water heating

Average climate ηwh (water heating efficiency) % -

Cold climate ηwh (water heating efficiency) % -

Warm climate ηwh (water heating efficiency) % -

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Cooling capacity Nom. kW 5.56 (1) / 4.37 (2) 5.96 (1) / 4.87 (2) 6.25 (1) / 5.35 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Cooling Nom. kW 0.940 (1) / 1.14 (2) 1.06 (1) / 1.33 (2) 1.16 (1) / 1.51 (2)

COP 5.10 (1) / 3.65 (2) 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

EER 5.94 (1) / 3.84 (2) 5.61 (1) / 3.67 (2) 5.40 (1) / 3.54 (2)

Pump Nominal ESP unit Cooling kPa 54.6 (1) / 59.4 (2) 52.6 (1) / 57.5 (2) 51.1 (1) / 55.5 (2)

Heating kPa 59.6 (1) / 58.6 (2) 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 15.9 (1) / 12.5 (2) 17.1 (1) / 14.0 (2) 17.9 (1) / 15.3 (2)

Heating Nom. l/min 12.3 (1) / 13.2 (2) 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBX04D6V/ERGA04DVA EHBX08D6V/ERGA06DVA EHBX08D6V/ERGA08DVA

• Heating • ERGA04-08DVA 11

Page 14: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

12

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBX08D9W/ERGA06DVA EHBX08D9W/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.25 3.27

Annual energy consumption

kWh 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.98

Pdh kW 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.16 3.18

Pdh kW 3.9 4.1

PERd % 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.49 4.54

Pdh kW 3.0

PERd % 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.43

Pdh kW 4.5

PERd % 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.5 3.0

Tbiv (bivalent temperature)

COPd 2.12 2.18

Pdh kW 6.1 6.4

PERd % 85 87

Tbiv °C -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 5,325 7,066

ηs (Seasonal space heating efficiency)

% 108 109

Prated at -22°C kW 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,858 1,983

ηs (Seasonal space heating efficiency)

% 158 159

Prated at 2°C kW 5.6 6.0

• Heating • ERGA04-08DVA

Page 15: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.47 4.56

Annual energy consumption

kWh 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.86 2.77

Pdh kW 6.0 7.0

PERd % 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.25 4.35

Pdh kW 3.9 4.2

PERd % 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.30 6.49

Pdh kW 3.2 3.3

PERd % 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.49 2.41

Pdh kW 6.0 6.9

PERd % 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 3.07 2.66

Pdh kW 6.1 7.5

PERd % 123 106

Tbiv °C -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,749 5,052

ηs (Seasonal space heating efficiency)

% 155 153

Prated at -22°C kW 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,276 1,437

ηs (Seasonal space heating efficiency)

% 248 257

Prated at 2°C kW 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBX08D9W/ERGA06DVA EHBX08D9W/ERGA08DVA

• Heating • ERGA04-08DVA 13

Page 16: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

14

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 9.0

Domestic hot water heating

Average climate ηwh (water heating efficiency) % -

Cold climate ηwh (water heating efficiency) % -

Warm climate ηwh (water heating efficiency) % -

Heating capacity Nom. kW 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Cooling capacity Nom. kW 5.96 (1) / 4.87 (2) 6.25 (1) / 5.35 (2)

Power input Heating Nom. kW 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Cooling Nom. kW 1.06 (1) / 1.33 (2) 1.16 (1) / 1.51 (2)

COP 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

EER 5.61 (1) / 3.67 (2) 5.40 (1) / 3.54 (2)

Pump Nominal ESP unit Cooling kPa 52.6 (1) / 57.5 (2) 51.1 (1) / 55.5 (2)

Heating kPa 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 17.1 (1) / 14.0 (2) 17.9 (1) / 15.3 (2)

Heating Nom. l/min 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHBX08D9W/ERGA06DVA EHBX08D9W/ERGA08DVA

• Heating • ERGA04-08DVA

Page 17: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S23DV/

ERGA04DVAEHVH08S23DV/

ERGA06DVAEHVH08S23DV/

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6.0 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98

Pdh kW 5.3 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.0 2.5 3.0

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79 85 87

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5.0 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 4.7 5.6 6.0

• Heating • ERGA04-08DVA 15

Page 18: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

16

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6.0 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 2.49 2.66

Pdh kW 5.5 6.0 7.5

PERd % 116 100 106

Tbiv °C -7 -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5.0 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5.2 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S23DV/

ERGA04DVAEHVH08S23DV/

ERGA06DVAEHVH08S23DV/

ERGA08DVA

• Heating • ERGA04-08DVA

Page 19: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Domestic hot water heating

General Declared load profile XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 1,252

ηwh (water heating efficiency) % 134

Qfuel (Daily fuel consumption) kWh 5.820

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 1,457

ηwh (water heating efficiency) % 115

Qelec (Daily electricity consumption) kWh 6.760

Warm climate AEC (Annual electricity consumption) kWh 1,033

ηwh (water heating efficiency) % 163

Qelec (Daily electricity consumption) kWh 4.810

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 3.01

COP 5.10 (1) / 3.65 (2) 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

Pump Nominal ESP unit Heating kPa 59.6 (1) / 58.6 (2) 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 12.3 (1) / 13.2 (2) 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S23DV/

ERGA04DVAEHVH08S23DV/

ERGA06DVAEHVH08S23DV/

ERGA08DVA

• Heating • ERGA04-08DVA 17

Page 20: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

18

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S23DVG/

ERGA04DVAEHVH08S23DVG/

ERGA06DVAEHVH08S23DVG/

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6.0 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98

Pdh kW 5.3 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.0 2.5 3.0

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79 85 87

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5.0 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 4.7 5.6 6.0

• Heating • ERGA04-08DVA

Page 21: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6.0 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 2.49 2.66

Pdh kW 5.5 6.0 7.5

PERd % 116 100 106

Tbiv °C -7 -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5.0 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5.2 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S23DVG/

ERGA04DVAEHVH08S23DVG/

ERGA06DVAEHVH08S23DVG/

ERGA08DVA

• Heating • ERGA04-08DVA 19

Page 22: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

20

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Domestic hot water heating

General Declared load profile XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 1,252

ηwh (water heating efficiency) % 134

Qfuel (Daily fuel consumption) kWh 5.820

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 1,457

ηwh (water heating efficiency) % 115

Qelec (Daily electricity consumption) kWh 6.760

Warm climate AEC (Annual electricity consumption) kWh 1,033

ηwh (water heating efficiency) % 163

Qelec (Daily electricity consumption) kWh 4.810

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 3.01

COP 5.10 (1) / 3.65 (2) 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

Pump Nominal ESP unit Heating kPa 59.6 (1) / 58.6 (2) 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 12.3 (1) / 13.2 (2) 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S23DVG/

ERGA04DVAEHVH08S23DVG/

ERGA06DVAEHVH08S23DVG/

ERGA08DVA

• Heating • ERGA04-08DVA

Page 23: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S18D6V/

ERGA04DVAEHVH04S23D6V/

ERGA04DVAEHVH08S18D6V/

ERGA06DVAEHVH08S23D6V/

ERGA06DVAEHVH08S18D6V/

ERGA08DVAEHVH08S23D6V/

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6.0 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98

Pdh kW 5.3 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.0 2.5 3.0

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79 85 87

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5.0 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 4.7 6.0 5.6 6.0

• Heating • ERGA04-08DVA 21

Page 24: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

22

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6.0 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.49 2.66

Pdh kW 5.5 6.1 6.0 7.5

PERd % 116 123 100 106

Tbiv °C -7 -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5.0 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5.2 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S18D6V/

ERGA04DVAEHVH04S23D6V/

ERGA04DVAEHVH08S18D6V/

ERGA06DVAEHVH08S23D6V/

ERGA06DVAEHVH08S18D6V/

ERGA08DVAEHVH08S23D6V/

ERGA08DVA

• Heating • ERGA04-08DVA

Page 25: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0 2,770.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 6.0

Domestic hot water heating

General Declared load profile L XL L XL L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 822 1,267 822 1,267 822 1,267

ηwh (water heating efficiency) % 125 133 125 133 125 133

Qfuel (Daily fuel consumption) kWh 3.870 5.900 3.870 5.900 3.870 5.900

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 951 1,475 951 1,475 951 1,475

ηwh (water heating efficiency) % 107 114 107 114 107 114

Qelec (Daily electricity consumption) kWh 4.480 3.860 4.480 6.860 4.480 6.860

Warm climate AEC (Annual electricity consumption) kWh 680 1,046 680 1,046 680 1,046

ηwh (water heating efficiency) % 151 161 151 161 151 161

Qelec (Daily electricity consumption) kWh 3.220 4.880 3.220 4.880 3.220 4.880

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 7.50 (1) / 7.80 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.63 (1) / 2.23 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01 2.48 3.01 2.48 3.01

COP 5.10 (1) / 3.65 (2) 4.60 (1) / 3.50 (2) 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

Pump Nominal ESP unit Heating kPa 59.6 (1) / 58.6 (2) 43.3 (1) / 41.2 (2) 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 12.3 (1) / 13.2 (2) 21.5 (1) / 22.4 (2) 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min 1h28min 1h40min 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S18D6V/

ERGA04DVAEHVH04S23D6V/

ERGA04DVAEHVH08S18D6V/

ERGA06DVAEHVH08S23D6V/

ERGA06DVAEHVH08S18D6V/

ERGA08DVAEHVH08S23D6V/

ERGA08DVA

• Heating • ERGA04-08DVA 23

Page 26: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

24

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S18D6VG

/ERGA04DVAEHVH04S23D6VG

/ERGA04DVAEHVH08S18D6VG

/ERGA06DVAEHVH08S23D6VG

/ERGA06DVAEHVH08S18D6VG

/ERGA08DVAEHVH08S23D6VG

/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6.0 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98

Pdh kW 5.3 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.0 2.5 3.0

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79 85 87

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5.0 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 4.7 6.0 5.6 6.0

• Heating • ERGA04-08DVA

Page 27: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6.0 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.49 2.66

Pdh kW 5.5 6.1 6.0 7.5

PERd % 116 123 100 106

Tbiv °C -7 -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5.0 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5.2 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S18D6VG

/ERGA04DVAEHVH04S23D6VG

/ERGA04DVAEHVH08S18D6VG

/ERGA06DVAEHVH08S23D6VG

/ERGA06DVAEHVH08S18D6VG

/ERGA08DVAEHVH08S23D6VG

/ERGA08DVA

• Heating • ERGA04-08DVA 25

Page 28: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

26

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0 2,770.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 6.0

Domestic hot water heating

General Declared load profile L XL L XL L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 822 1,267 822 1,267 822 1,267

ηwh (water heating efficiency) % 125 133 125 133 125 133

Qfuel (Daily fuel consumption) kWh 3.870 5.900 3.870 5.900 3.870 5.900

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 951 1,475 951 1,475 951 1,475

ηwh (water heating efficiency) % 107 114 107 114 107 114

Qelec (Daily electricity consumption) kWh 4.480 3.860 4.480 6.860 4.480 6.860

Warm climate AEC (Annual electricity consumption) kWh 680 1,046 680 1,046 680 1,046

ηwh (water heating efficiency) % 151 161 151 161 151 161

Qelec (Daily electricity consumption) kWh 3.220 4.880 3.220 4.880 3.220 4.880

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 7.50 (1) / 7.80 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.63 (1) / 2.23 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01 2.48 3.01 2.48 3.01

COP 5.10 (1) / 3.65 (2) 4.60 (1) / 3.50 (2) 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

Pump Nominal ESP unit Heating kPa 59.6 (1) / 58.6 (2) 43.3 (1) / 41.2 (2) 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 12.3 (1) / 13.2 (2) 21.5 (1) / 22.4 (2) 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min 1h28min 1h40min 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH04S18D6VG

/ERGA04DVAEHVH04S23D6VG

/ERGA04DVAEHVH08S18D6VG

/ERGA06DVAEHVH08S23D6VG

/ERGA06DVAEHVH08S18D6VG

/ERGA08DVAEHVH08S23D6VG

/ERGA08DVA

• Heating • ERGA04-08DVA

Page 29: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH08S18D9W/

ERGA06DVAEHVH08S23D9W/

ERGA06DVAEHVH08S18D9W/

ERGA08DVAEHVH08S23D9W/

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.25 3.27

Annual energy consumption

kWh 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.98

Pdh kW 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.16 3.18

Pdh kW 3.9 4.1

PERd % 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.49 4.54

Pdh kW 3.0

PERd % 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.43

Pdh kW 4.5

PERd % 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.5 3.0

Tbiv (bivalent temperature)

COPd 2.12 2.18

Pdh kW 6.1 6.4

PERd % 85 87

Tbiv °C -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 5,325 7,066

ηs (Seasonal space heating efficiency)

% 108 109

Prated at -22°C kW 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,858 1,983

ηs (Seasonal space heating efficiency)

% 158 159

Prated at 2°C kW 6.0 5.6 6.0

• Heating • ERGA04-08DVA 27

Page 30: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

28

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.47 4.56

Annual energy consumption

kWh 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.86 2.77

Pdh kW 6.0 7.0

PERd % 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.25 4.35

Pdh kW 3.9 4.2

PERd % 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.30 6.49

Pdh kW 3.2 3.3

PERd % 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.49 2.41

Pdh kW 6.0 6.9

PERd % 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 3.07 2.49 2.66

Pdh kW 6.1 6.0 7.5

PERd % 123 100 106

Tbiv °C -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,749 5,052

ηs (Seasonal space heating efficiency)

% 155 153

Prated at -22°C kW 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,276 1,437

ηs (Seasonal space heating efficiency)

% 248 257

Prated at 2°C kW 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH08S18D9W/

ERGA06DVAEHVH08S23D9W/

ERGA06DVAEHVH08S18D9W/

ERGA08DVAEHVH08S23D9W/

ERGA08DVA

• Heating • ERGA04-08DVA

Page 31: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,770.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 9.0

Domestic hot water heating

General Declared load profile L XL L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 822 1,267 822 1,267

ηwh (water heating efficiency) % 125 133 125 133

Qfuel (Daily fuel consumption) kWh 3.870 5.900 3.870 5.900

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 951 1,475 951 1,475

ηwh (water heating efficiency) % 107 114 107 114

Qelec (Daily electricity consumption) kWh 4.480 6.860 4.480 6.860

Warm climate AEC (Annual electricity consumption) kWh 680 1,046 680 1,046

ηwh (water heating efficiency) % 151 161 151 161

Qelec (Daily electricity consumption) kWh 3.220 4.880 3.220 4.880

Heating capacity Nom. kW 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01 2.48 3.01

COP 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

Pump Nominal ESP unit Heating kPa 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH08S18D9W/

ERGA06DVAEHVH08S23D9W/

ERGA06DVAEHVH08S18D9W/

ERGA08DVAEHVH08S23D9W/

ERGA08DVA

• Heating • ERGA04-08DVA 29

Page 32: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

30

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH08S18D9WG/

ERGA06DVAEHVH08S23D9WG /

ERGA06DVAEHVH08S18D9WG/

ERGA08DVAEHVH08S23D9WG /

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.25 3.27

Annual energy consumption

kWh 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.98

Pdh kW 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.16 3.18

Pdh kW 3.9 4.1

PERd % 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.49 4.54

Pdh kW 3.0

PERd % 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.43

Pdh kW 4.5

PERd % 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.5 3.0

Tbiv (bivalent temperature)

COPd 2.12 2.18

Pdh kW 6.1 6.4

PERd % 85 87

Tbiv °C -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 5,325 7,066

ηs (Seasonal space heating efficiency)

% 108 109

Prated at -22°C kW 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,858 1,983

ηs (Seasonal space heating efficiency)

% 158 159

Prated at 2°C kW 6.0 5.6 6.0

• Heating • ERGA04-08DVA

Page 33: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.47 4.56

Annual energy consumption

kWh 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.86 2.77

Pdh kW 6.0 7.0

PERd % 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.25 4.35

Pdh kW 3.9 4.2

PERd % 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.30 6.49

Pdh kW 3.2 3.3

PERd % 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.49 2.41

Pdh kW 6.0 6.9

PERd % 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 3.07 2.49 2.66

Pdh kW 6.1 6.0 7.5

PERd % 123 100 106

Tbiv °C -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,749 5,052

ηs (Seasonal space heating efficiency)

% 155 153

Prated at -22°C kW 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,276 1,437

ηs (Seasonal space heating efficiency)

% 248 257

Prated at 2°C kW 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH08S18D9WG/

ERGA06DVAEHVH08S23D9WG /

ERGA06DVAEHVH08S18D9WG/

ERGA08DVAEHVH08S23D9WG /

ERGA08DVA

• Heating • ERGA04-08DVA 31

Page 34: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

32

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,770.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 9.0

Domestic hot water heating

General Declared load profile L XL L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 822 1,267 822 1,267

ηwh (water heating efficiency) % 125 133 125 133

Qfuel (Daily fuel consumption) kWh 3.870 5.900 3.870 5.900

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 951 1,475 951 1,475

ηwh (water heating efficiency) % 107 114 107 114

Qelec (Daily electricity consumption) kWh 4.480 6.860 4.480 6.860

Warm climate AEC (Annual electricity consumption) kWh 680 1,046 680 1,046

ηwh (water heating efficiency) % 151 161 151 161

Qelec (Daily electricity consumption) kWh 3.220 4.880 3.220 4.880

Heating capacity Nom. kW 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01 2.48 3.01

COP 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

Pump Nominal ESP unit Heating kPa 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVH08S18D9WG/

ERGA06DVAEHVH08S23D9WG /

ERGA06DVAEHVH08S18D9WG/

ERGA08DVAEHVH08S23D9WG /

ERGA08DVA

• Heating • ERGA04-08DVA

Page 35: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHVX04S18D3V/ERGA04DVA EHVX04S23D3V/ERGA04DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26

Annual energy consumption

kWh 3,806

ηs (Seasonal space heating efficiency)

% 127

Prated at -10°C kW 6.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97

Pdh kW 5.3

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23

Pdh kW 3.3

PERd % 129

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40

Pdh kW 3.0

PERd % 176

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10

Pdh kW 3.3

PERd % 244

Tol (temperature operating limit)

COPd 1.37

Pdh kW 4.0

PERd % 55

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.0

Tbiv (bivalent temperature)

COPd 1.97

Pdh kW 5.3

PERd % 79

Tbiv °C -7

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468

ηs (Seasonal space heating efficiency)

% 107

Prated at -22°C kW 5.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660

ηs (Seasonal space heating efficiency)

% 148

Prated at 2°C kW 4.7

• Heating • ERGA04-08DVA 33

Page 36: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

34

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48

Annual energy consumption

kWh 2,766

ηs (Seasonal space heating efficiency)

% 176

Prated at -10°C kW 6.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90

Pdh kW 5.5

PERd % 116

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33

Pdh kW 3.3

PERd % 173

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19

Pdh kW 3.2

PERd % 248

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78

Pdh kW 3.3

PERd % 311

Tol (temperature operating limit)

COPd 2.56

Pdh kW 5.2

PERd % 102

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90

Pdh kW 5.5

PERd % 116

Tbiv °C -7

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230

ηs (Seasonal space heating efficiency)

% 150

Prated at -22°C kW 5.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139

ηs (Seasonal space heating efficiency)

% 241

Prated at 2°C kW 5.2

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHVX04S18D3V/ERGA04DVA EHVX04S23D3V/ERGA04DVA

• Heating • ERGA04-08DVA

Page 37: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 3.0

Domestic hot water heating

General Declared load profile L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 805 1,252

ηwh (water heating efficiency) % 127 134

Qfuel (Daily fuel consumption) kWh 3.780 5.820

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 932 1,457

ηwh (water heating efficiency) % 110 115

Qelec (Daily electricity consumption) kWh 4.370 6.760

Warm climate AEC (Annual electricity consumption) kWh 668 1,033

ηwh (water heating efficiency) % 154 163

Qelec (Daily electricity consumption) kWh 3.150 4.810

Heating capacity Nom. kW 4.30 (1) / 4.60 (2)

Cooling capacity Nom. kW 5.56 (1) / 4.37 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2)

Cooling Nom. kW 0.940 (1) / 1.14 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01

COP 5.10 (1) / 3.65 (2)

EER 5.94 (1) / 3.84 (2)

Pump Nominal ESP unit Cooling kPa 54.6 (1) / 59.4 (2)

Heating kPa 59.6 (1) / 58.6 (2)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 15.9 (1) / 12.5 (2)

Heating Nom. l/min 12.3 (1) / 13.2 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHVX04S18D3V/ERGA04DVA EHVX04S23D3V/ERGA04DVA

• Heating • ERGA04-08DVA 35

Page 38: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

36

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHVX04S18D3VG/ERGA04DVA EHVX04S23D3VG/ERGA04DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26

Annual energy consumption

kWh 3,806

ηs (Seasonal space heating efficiency)

% 127

Prated at -10°C kW 6.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97

Pdh kW 5.3

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23

Pdh kW 3.3

PERd % 129

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40

Pdh kW 3.0

PERd % 176

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10

Pdh kW 3.3

PERd % 244

Tol (temperature operating limit)

COPd 1.37

Pdh kW 4.0

PERd % 55

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.0

Tbiv (bivalent temperature)

COPd 1.97

Pdh kW 5.3

PERd % 79

Tbiv °C -7

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468

ηs (Seasonal space heating efficiency)

% 107

Prated at -22°C kW 5.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660

ηs (Seasonal space heating efficiency)

% 148

Prated at 2°C kW 4.7

• Heating • ERGA04-08DVA

Page 39: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48

Annual energy consumption

kWh 2,766

ηs (Seasonal space heating efficiency)

% 176

Prated at -10°C kW 6.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90

Pdh kW 5.5

PERd % 116

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33

Pdh kW 3.3

PERd % 173

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19

Pdh kW 3.2

PERd % 248

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78

Pdh kW 3.3

PERd % 311

Tol (temperature operating limit)

COPd 2.56

Pdh kW 5.2

PERd % 102

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90

Pdh kW 5.5

PERd % 116

Tbiv °C -7

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230

ηs (Seasonal space heating efficiency)

% 150

Prated at -22°C kW 5.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139

ηs (Seasonal space heating efficiency)

% 241

Prated at 2°C kW 5.2

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHVX04S18D3VG/ERGA04DVA EHVX04S23D3VG/ERGA04DVA

• Heating • ERGA04-08DVA 37

Page 40: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

38

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 3.0

Domestic hot water heating

General Declared load profile L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 805 1,252

ηwh (water heating efficiency) % 127 134

Qfuel (Daily fuel consumption) kWh 3.780 5.820

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 932 1,457

ηwh (water heating efficiency) % 110 115

Qelec (Daily electricity consumption) kWh 4.370 6.760

Warm climate AEC (Annual electricity consumption) kWh 668 1,033

ηwh (water heating efficiency) % 154 163

Qelec (Daily electricity consumption) kWh 3.150 4.810

Heating capacity Nom. kW 4.30 (1) / 4.60 (2)

Cooling capacity Nom. kW 5.56 (1) / 4.37 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2)

Cooling Nom. kW 0.940 (1) / 1.14 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01

COP 5.10 (1) / 3.65 (2)

EER 5.94 (1) / 3.84 (2)

Pump Nominal ESP unit Cooling kPa 54.6 (1) / 59.4 (2)

Heating kPa 59.6 (1) / 58.6 (2)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 15.9 (1) / 12.5 (2)

Heating Nom. l/min 12.3 (1) / 13.2 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power input EHVX04S18D3VG/ERGA04DVA EHVX04S23D3VG/ERGA04DVA

• Heating • ERGA04-08DVA

Page 41: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX04S18D6V

/ERGA04DVAEHVX04S23D6V

/ERGA04DVAEHVX08S18D6V

/ERGA06DVAEHVX08S23D6V

/ERGA06DVAEHVX08S18D6V

/ERGA08DVAEHVX08S23D6V

/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6.0 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98

Pdh kW 5.3 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.0 2.5 3.0

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79 85 87

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5.0 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 4.7 6.0 5.6 6.0

• Heating • ERGA04-08DVA 39

Page 42: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

40

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6.0 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.49 2.66

Pdh kW 5.5 6.1 6.0 7.5

PERd % 116 123 100 106

Tbiv °C -7 -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5.0 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5.2 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX04S18D6V

/ERGA04DVAEHVX04S23D6V

/ERGA04DVAEHVX08S18D6V

/ERGA06DVAEHVX08S23D6V

/ERGA06DVAEHVX08S18D6V

/ERGA08DVAEHVX08S23D6V

/ERGA08DVA

• Heating • ERGA04-08DVA

Page 43: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0 2,770.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 6.0

Domestic hot water heating

General Declared load profile L XL L XL L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 822 1,267 822 1,267 822 1,267

ηwh (water heating efficiency) % 125 133 125 133 125 133

Qfuel (Daily fuel consumption) kWh 3.870 5.900 3.870 5.900 3.870 5.900

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 951 1,475 951 1,475 951 1,475

ηwh (water heating efficiency) % 107 114 107 114 107 114

Qelec (Daily electricity consumption) kWh 4.480 6.760 4.480 6.860 4.480 6.860

Warm climate AEC (Annual electricity consumption) kWh 680 1,033 680 1,046 680 1,046

ηwh (water heating efficiency) % 151 163 151 161 151 161

Qelec (Daily electricity consumption) kWh 3.220 4.880 3.220 4.880 3.220 4.880

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Cooling capacity Nom. kW 5.56 (1) / 4.37 (2) 5.96 (1) / 4.87 (2) 6.25 (1) / 5.35 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Cooling Nom. kW 0.940 (1) / 1.14 (2) 1.06 (1) / 1.33 (2) 1.16 (1) / 1.51 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01 2.48 3.01 2.48 3.01

COP 5.10 (1) / 3.65 (2) 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

EER 5.94 (1) / 3.84 (2) 5.61 (1) / 3.67 (2) 5.40 (1) / 3.54 (2)

Pump Nominal ESP unit Cooling kPa 54.6 (1) / 59.4 (2) 52.6 (1) / 57.5 (2) 51.1 (1) / 55.5 (2)

Heating kPa 59.6 (1) / 58.6 (2) 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 15.9 (1) / 12.5 (2) 17.1 (1) / 14.0 (2) 17.9 (1) / 15.3 (2)

Heating Nom. l/min 12.3 (1) / 13.2 (2) 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min 1h28min 1h40min 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX04S18D6V

/ERGA04DVAEHVX04S23D6V

/ERGA04DVAEHVX08S18D6V

/ERGA06DVAEHVX08S23D6V

/ERGA06DVAEHVX08S18D6V

/ERGA08DVAEHVX08S23D6V

/ERGA08DVA

• Heating • ERGA04-08DVA 41

Page 44: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

42

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX04S18D6VG/

ERGA04DVAEHVX04S23D6VG/

ERGA04DVAEHVX08S18D6VG/

ERGA06DVAEHVX08S23D6VG/

ERGA06DVAEHVX08S18D6VG/

ERGA08DVAEHVX08S23D6VG/

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6.0 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98

Pdh kW 5.3 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.0 2.5 3.0

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79 85 87

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5.0 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 4.7 6.0 5.6 6.0

• Heating • ERGA04-08DVA

Page 45: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6.0 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.49 2.66

Pdh kW 5.5 6.1 6.0 7.5

PERd % 116 123 100 106

Tbiv °C -7 -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 0.5 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5.0 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5.2 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX04S18D6VG/

ERGA04DVAEHVX04S23D6VG/

ERGA04DVAEHVX08S18D6VG/

ERGA06DVAEHVX08S23D6VG/

ERGA06DVAEHVX08S18D6VG/

ERGA08DVAEHVX08S23D6VG/

ERGA08DVA

• Heating • ERGA04-08DVA 43

Page 46: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

44

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280.0 2,770.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 6.0

Domestic hot water heating

General Declared load profile L XL L XL L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 822 1,267 822 1,267 822 1,267

ηwh (water heating efficiency) % 125 133 125 133 125 133

Qfuel (Daily fuel consumption) kWh 3.870 5.900 3.870 5.900 3.870 5.900

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 951 1,475 951 1,475 951 1,475

ηwh (water heating efficiency) % 107 114 107 114 107 114

Qelec (Daily electricity consumption) kWh 4.480 6.760 4.480 6.860 4.480 6.860

Warm climate AEC (Annual electricity consumption) kWh 680 1,033 680 1,046 680 1,046

ηwh (water heating efficiency) % 151 163 151 161 151 161

Qelec (Daily electricity consumption) kWh 3.220 4.880 3.220 4.880 3.220 4.880

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Cooling capacity Nom. kW 5.56 (1) / 4.37 (2) 5.96 (1) / 4.87 (2) 6.25 (1) / 5.35 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Cooling Nom. kW 0.940 (1) / 1.14 (2) 1.06 (1) / 1.33 (2) 1.16 (1) / 1.51 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01 2.48 3.01 2.48 3.01

COP 5.10 (1) / 3.65 (2) 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

EER 5.94 (1) / 3.84 (2) 5.61 (1) / 3.67 (2) 5.40 (1) / 3.54 (2)

Pump Nominal ESP unit Cooling kPa 54.6 (1) / 59.4 (2) 52.6 (1) / 57.5 (2) 51.1 (1) / 55.5 (2)

Heating kPa 59.6 (1) / 58.6 (2) 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 15.9 (1) / 12.5 (2) 17.1 (1) / 14.0 (2) 17.9 (1) / 15.3 (2)

Heating Nom. l/min 12.3 (1) / 13.2 (2) 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min 1h28min 1h40min 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX04S18D6VG/

ERGA04DVAEHVX04S23D6VG/

ERGA04DVAEHVX08S18D6VG/

ERGA06DVAEHVX08S23D6VG/

ERGA06DVAEHVX08S18D6VG/

ERGA08DVAEHVX08S23D6VG/

ERGA08DVA

• Heating • ERGA04-08DVA

Page 47: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX08S18D9W/

ERGA06DVAEHVX08S23D9W/

ERGA06DVAEHVX08S18D9W/

ERGA08DVAEHVX08S23D9W/

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.25 3.27

Annual energy consumption

kWh 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.98

Pdh kW 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.16 3.18

Pdh kW 3.9 4.1

PERd % 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.49 4.54

Pdh kW 3.0

PERd % 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.43

Pdh kW 4.5

PERd % 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.5 3.0

Tbiv (bivalent temperature)

COPd 2.12 2.18

Pdh kW 6.1 6.4

PERd % 85 87

Tbiv °C -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 5,325 7,066

ηs (Seasonal space heating efficiency)

% 108 109

Prated at -22°C kW 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,858 1,983

ηs (Seasonal space heating efficiency)

% 158 159

Prated at 2°C kW 6.0 5.6 6.0

• Heating • ERGA04-08DVA 45

Page 48: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

46

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.47 4.56

Annual energy consumption

kWh 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.86 2.77

Pdh kW 6.0 7.0

PERd % 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.25 4.35

Pdh kW 3.9 4.2

PERd % 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.30 6.49

Pdh kW 3.2 3.3

PERd % 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.49 2.41

Pdh kW 6.0 6.9

PERd % 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 3.07 2.49 2.66

Pdh kW 6.1 6.0 7.5

PERd % 123 100 106

Tbiv °C -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,749 5,052

ηs (Seasonal space heating efficiency)

% 155 153

Prated at -22°C kW 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,276 1,437

ηs (Seasonal space heating efficiency)

% 248 257

Prated at 2°C kW 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX08S18D9W/

ERGA06DVAEHVX08S23D9W/

ERGA06DVAEHVX08S18D9W/

ERGA08DVAEHVX08S23D9W/

ERGA08DVA

• Heating • ERGA04-08DVA

Page 49: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,770.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 9.0

Domestic hot water heating

General Declared load profile L XL L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 822 1,267 822 1,267

ηwh (water heating efficiency) % 125 133 125 133

Qfuel (Daily fuel consumption) kWh 3.870 5.900 3.870 5.900

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 951 1,475 951 1,475

ηwh (water heating efficiency) % 107 114 107 114

Qelec (Daily electricity consumption) kWh 4.480 6.860 4.480 6.860

Warm climate AEC (Annual electricity consumption) kWh 680 1,046 680 1,046

ηwh (water heating efficiency) % 151 161 151 161

Qelec (Daily electricity consumption) kWh 3.220 4.880 3.220 4.880

Heating capacity Nom. kW 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Cooling capacity Nom. kW 5.96 (1) / 4.87 (2) 6.25 (1) / 5.35 (2)

Power input Heating Nom. kW 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Cooling Nom. kW 1.06 (1) / 1.33 (2) 1.16 (1) / 1.51 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01 2.48 3.01

COP 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

EER 5.61 (1) / 3.67 (2) 5.40 (1) / 3.54 (2)

Pump Nominal ESP unit Cooling kPa 52.6 (1) / 57.5 (2) 51.1 (1) / 55.5 (2)

Heating kPa 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 17.1 (1) / 14.0 (2) 17.9 (1) / 15.3 (2)

Heating Nom. l/min 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX08S18D9W/

ERGA06DVAEHVX08S23D9W/

ERGA06DVAEHVX08S18D9W/

ERGA08DVAEHVX08S23D9W/

ERGA08DVA

• Heating • ERGA04-08DVA 47

Page 50: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

48

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX08S18D9WG/

ERGA06DVAEHVX08S23D9WG/

ERGA06DVAEHVX08S18D9WG/

ERGA08DVAEHVX08S23D9WG/

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.25 3.27

Annual energy consumption

kWh 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 7.0 7.5

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.98

Pdh kW 5.9

PERd % 79

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.16 3.18

Pdh kW 3.9 4.1

PERd % 126 127

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.49 4.54

Pdh kW 3.0

PERd % 180 182

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244 246

Tol (temperature operating limit)

COPd 1.43

Pdh kW 4.5

PERd % 57

TOL °C -10

WTOL °C 55

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 2.5 3.0

Tbiv (bivalent temperature)

COPd 2.12 2.18

Pdh kW 6.1 6.4

PERd % 85 87

Tbiv °C -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 5,325 7,066

ηs (Seasonal space heating efficiency)

% 108 109

Prated at -22°C kW 6.0 8.0

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,858 1,983

ηs (Seasonal space heating efficiency)

% 158 159

Prated at 2°C kW 6.0 5.6 6.0

• Heating • ERGA04-08DVA

Page 51: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.47 4.56

Annual energy consumption

kWh 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 7.0 8.0

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.86 2.77

Pdh kW 6.0 7.0

PERd % 114 111

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.25 4.35

Pdh kW 3.9 4.2

PERd % 170 174

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.30 6.49

Pdh kW 3.2 3.3

PERd % 252 260

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311 341

Tol (temperature operating limit)

COPd 2.49 2.41

Pdh kW 6.0 6.9

PERd % 100 96

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 3.07 2.49 2.66

Pdh kW 6.1 6.0 7.5

PERd % 123 100 106

Tbiv °C -6 -8

Rated heat output supplementary capacity

Psup (at Tdesign -10°C)

kW 1.0

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,749 5,052

ηs (Seasonal space heating efficiency)

% 155 153

Prated at -22°C kW 6.0 8.0

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,276 1,437

ηs (Seasonal space heating efficiency)

% 248 257

Prated at 2°C kW 6.0 7.0

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX08S18D9WG/

ERGA06DVAEHVX08S23D9WG/

ERGA06DVAEHVX08S18D9WG/

ERGA08DVAEHVX08S23D9WG/

ERGA08DVA

• Heating • ERGA04-08DVA 49

Page 52: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

50

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,770.0 2,520.0 2,770.0

Brine/water to water unit

Rated water/brine flow m³/h 0.0

Other Capacity control Inverter

Pck (Crankcase heater mode) kW 0.000

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Psup kW 9.0

Domestic hot water heating

General Declared load profile L XL L XL

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 822 1,267 822 1,267

ηwh (water heating efficiency) % 125 133 125 133

Qfuel (Daily fuel consumption) kWh 3.870 5.900 3.870 5.900

Water heating energy efficiency class A

Cold climate AEC (Annual electricity consumption) kWh 951 1,475 951 1,475

ηwh (water heating efficiency) % 107 114 107 114

Qelec (Daily electricity consumption) kWh 4.480 6.860 4.480 6.860

Warm climate AEC (Annual electricity consumption) kWh 680 1,046 680 1,046

ηwh (water heating efficiency) % 151 161 151 161

Qelec (Daily electricity consumption) kWh 3.220 4.880 3.220 4.880

Heating capacity Nom. kW 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2)

Cooling capacity Nom. kW 5.96 (1) / 4.87 (2) 6.25 (1) / 5.35 (2)

Power input Heating Nom. kW 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Cooling Nom. kW 1.06 (1) / 1.33 (2) 1.16 (1) / 1.51 (2)

Domestic hot water from 10°C to 50°C

Nom. kWh 2.48 3.01 2.48 3.01

COP 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)

EER 5.61 (1) / 3.67 (2) 5.40 (1) / 3.54 (2)

Pump Nominal ESP unit Cooling kPa 52.6 (1) / 57.5 (2) 51.1 (1) / 55.5 (2)

Heating kPa 52.4 (1) / 52.9 (2) 43.3 (1) / 41.2 (2)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 17.1 (1) / 14.0 (2) 17.9 (1) / 15.3 (2)

Heating Nom. l/min 17.2 (1) / 16.9 (2) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater No

Low-temperature heat pump No

Supplementary heater integrated Yes

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 42

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

Heat up time from 10°C to 50°C hr 1h28min 1h40min 1h28min 1h40min

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHVX08S18D9WG/

ERGA06DVAEHVX08S23D9WG/

ERGA06DVAEHVX08S18D9WG/

ERGA08DVAEHVX08S23D9WG/

ERGA08DVA

• Heating • ERGA04-08DVA

Page 53: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSX04P30DA/ERGA04DVA

EHSX04P50DA/ERGA04DVA

EHSX08P30DA/ERGA06DVA

EHSX08P50DA/ERGA06DVA

EHSX08P30DA/ERGA08DVA

EHSX08P50DA/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6 7 8

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98 198.00

Pdh kW 5.3 5.9

PERd % 79.0

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129.0 126.0 127.0

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176.0 180.0 182.0

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244.0 246.0

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55.0 57.0

TOL °C -10

WTOL °C 55

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79.0 85.0 87.0

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5 6 8

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 5 6

• Heating • ERGA04-08DVA 51

Page 54: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

52

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6 7 8

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116.0 114.0 111.0

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173.0 170.0 174.0

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248.0 252.0 260.0

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311.0 341.0

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102.0 100.0 96.0

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.66

Pdh kW 5.5 6.1 7.5

PERd % 116.0 123.0 106.0

Tbiv °C -7 -6 -8

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5 6 8

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437

ηs (Seasonal space heating efficiency)

% 241 248 257

Prated at 2°C kW 5 6 7

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280 27,770 2,770

Other Capacity control Inverter

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Type of energy input Electrical

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSX04P30DA/ERGA04DVA

EHSX04P50DA/ERGA04DVA

EHSX08P30DA/ERGA06DVA

EHSX08P50DA/ERGA06DVA

EHSX08P30DA/ERGA08DVA

EHSX08P50DA/ERGA08DVA

• Heating • ERGA04-08DVA

Page 55: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Domestic hot water heating

General Declared load profile L XL L XL L XL

Heat up time from 10°C to 50°C min 91 177 91 177 91 177

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 951 1,584 951 1,584 951 1,584

ηwh (water heating efficiency) % 108 106 108 106 108 106

Qelec (Daily electricity consumption) kWh 4,500 7,426 4,500 7,426 4,500 7,426

Water heating energy efficiency class - A - A -

Cold climate AEC (Annual electricity consumption) kWh 1,366 2,260 1,366 2,260 1,366 2,260

ηwh (water heating efficiency) % 75

Qelec (Daily electricity consumption) kWh 6.454 10.520 6.454 10.520 6.454 10.520

Warm climate AEC (Annual electricity consumption) kWh 940 1,436 940 1,436 940 1,436

ηwh (water heating efficiency) % 109 117 109 117 109 117

Qelec (Daily electricity consumption) kWh 4.513 6.766 4.513 6.766 4.513 6.766

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 5.90 (2) / 6.00 (1) 7.50 (1) / 7.80 (2)

Cooling capacity Nom. kW 5.56 (1) / 4.37 (2) 4.87 (2) / 5.96 (1) 5.35 (2) / 6.25 (1)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Cooling Nom. kW 0.940 (1) / 1.14 (2) 1.06 (1) / 1.33 (2) 1.16 (1) / 1.51 (2)

COP 5.10 (1) / 3.65 (2) 3.50 (2) / 4.85 (1) 3.50 (2) / 4.60 (1)

EER 5.94 (1) / 3.84 (2) 3.67 (2) / 5.61 (1) 3.54 (2) / 5.40 (1)

Pump Type Grundfos UPM3K 25-75 CHBL

-

Nominal ESP unit Cooling kPa 60.5 (1) / 65.8 (2) 57.6 (1) / 63.9 (2) 55.5 (1) / 61.7 (2)

Heating kPa 66.0 (1) / 65.0 (2) 57.4 (1) / 58.1 (2) 38.7 (2) / 42.7 (1)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 15.9 (1) / 12.5 (2) 14.0 (2) / 17.1 (1) 15.3 (2) / 17.9 (1)

Heating Nom. l/min 12.3 (1) / 13.2 (2) 16.9 (2) / 17.2 (1) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater Yes

Low-temperature heat pump No

Supplementary heater integrated No

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 39

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSX04P30DA/ERGA04DVA

EHSX04P50DA/ERGA04DVA

EHSX08P30DA/ERGA06DVA

EHSX08P50DA/ERGA06DVA

EHSX08P30DA/ERGA08DVA

EHSX08P50DA/ERGA08DVA

• Heating • ERGA04-08DVA 53

Page 56: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

54

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSXB04P30DA/ERGA04DVA

EHSXB04P50DA/ERGA04DVA

EHSXB08P30DA/ERGA06DVA

EHSXB08P50DA/ERGA06DVA

EHSXB08P30DA/ERGA08DVA

EHSXB08P50DA/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6 7 8

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98 198.00

Pdh kW 5.3 5.9

PERd % 79.0

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129.0 126.0 127.0

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176.0 180.0 182.0

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244.0 246.0

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0

55.0

4.5

PERd % 57.0

TOL °C -10

WTOL °C 55

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79.0 85.0 87.0

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5 6 8

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 5 6

• Heating • ERGA04-08DVA

Page 57: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6 7 8

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116.0 114.0 111.0

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173.0 170.0 174.0

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248.0 252.0 260.0

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311.0 341.0

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102.0 100.0 96.0

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.66

Pdh kW 5.5 6.1 7.5

PERd % 116.0 123.0 106.0

Tbiv °C -7 -6 -8

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5 6 8

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437 -

ηs (Seasonal space heating efficiency)

% 241 248 257 -

Prated at 2°C kW 5 6 7 -

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280 27,770 2,770

Other Capacity control Inverter

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Type of energy input Electrical

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSXB04P30DA/ERGA04DVA

EHSXB04P50DA/ERGA04DVA

EHSXB08P30DA/ERGA06DVA

EHSXB08P50DA/ERGA06DVA

EHSXB08P30DA/ERGA08DVA

EHSXB08P50DA/ERGA08DVA

• Heating • ERGA04-08DVA 55

Page 58: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

56

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Domestic hot water heating

General Declared load profile L XL L XL L XL

Heat up time from 10°C to 50°C min 91 158 91 158 91 158

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 951 1,541 951 1,541 951 1,541

ηwh (water heating efficiency) % 108 109 108 109 108 109

Qelec (Daily electricity consumption) kWh 4,500 7,251 4,500 7,251 4,500 7,251

Water heating energy efficiency class A - A - A -

Cold climate AEC (Annual electricity consumption) kWh 1,366 1,852 1,366 1,852 1,366 1,852

ηwh (water heating efficiency) % 75 90 75 90 75 90

Qelec (Daily electricity consumption) kWh 6.454 8.665 6.454 8.665 6.454 8.665

Warm climate AEC (Annual electricity consumption) kWh 940 1,343 940 1,343 940 1,343

ηwh (water heating efficiency) % 109 125 109 125 109 125

Qelec (Daily electricity consumption) kWh 4.513 6.346 4.513 6.346 4.513 6.346

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 5.90 (2) / 6.00 (1) 7.50 (1) / 7.80 (2)

Cooling capacity Nom. kW 5.56 (1) / 4.37 (2) 4.87 (2) / 5.96 (1) 5.35 (2) / 6.25 (1)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

Cooling Nom. kW 0.940 (1) / 1.14 (2) 1.06 (1) / 1.33 (2) 1.16 (1) / 1.51 (2)

COP 5.10 (1) / 3.65 (2) 3.50 (2) / 4.85 (1) 3.50 (2) / 4.60 (1)

EER 5.94 (1) / 3.84 (2) 3.67 (2) / 5.61 (1) 3.54 (2) / 5.40 (1)

Pump Type Grundfos UPM3K 25-75 CHBL

-

Nominal ESP unit Cooling kPa 60.5 (1) / 65.8 (2) 57.6 (1) / 63.9 (2) 55.5 (1) / 61.7 (2)

Heating kPa 66.0 (1) / 65.0 (2) 57.4 (1) / 58.1 (2) 38.7 (2) / 42.7 (1)

Water side Heat exchanger

Water flow rate Cooling Nom. l/min 15.9 (1) / 12.5 (2) 14.0 (2) / 17.1 (1) 15.3 (2) / 17.9 (1)

Heating Nom. l/min 12.3 (1) / 13.2 (2) 16.9 (2) / 17.2 (1) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater Yes

Low-temperature heat pump No

Supplementary heater integrated No

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 39

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSXB04P30DA/ERGA04DVA

EHSXB04P50DA/ERGA04DVA

EHSXB08P30DA/ERGA06DVA

EHSXB08P50DA/ERGA06DVA

EHSXB08P30DA/ERGA08DVA

EHSXB08P50DA/ERGA08DVA

• Heating • ERGA04-08DVA

Page 59: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSH04P30DA/

ERGA04DVAEHSH08P30DA/

ERGA06DVAEHSH08P50DA/

ERGA06DVAEHSH08P30DA/

ERGA08DVAEHSH08P50DA/

ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6 7 8

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98 198.00

Pdh kW 5.3 5.9

PERd % 79.0

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129.0 126.0 127.0

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176.0 180.0 182.0

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244.0 246.0

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55.0 57.0

TOL °C -10

WTOL °C 55

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79.0 85.0 87.0

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5 6 8

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 5 6

• Heating • ERGA04-08DVA 57

Page 60: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

58

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6 7 8

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116.0 114.0 111.0

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173.0 170.0 174.0

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248.0 252.0 260.0

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311.0 341.0

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102.0 100.0 96.0

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.66

Pdh kW 5.5 6.1 7.5

PERd % 116.0 123.0 106.0

Tbiv °C -7 -6 -8

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5 6 8

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437 -

ηs (Seasonal space heating efficiency)

% 241 248 257 -

Prated at 2°C kW 5 6 7 -

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280 27,770 2,770

Other Capacity control Inverter

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Type of energy input Electrical

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSH04P30DA/

ERGA04DVAEHSH08P30DA/

ERGA06DVAEHSH08P50DA/

ERGA06DVAEHSH08P30DA/

ERGA08DVAEHSH08P50DA/

ERGA08DVA

• Heating • ERGA04-08DVA

Page 61: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Domestic hot water heating

General Declared load profile L L XL L XL

Heat up time from 10°C to 50°C min 91 177 91 177 177

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 951 1,584 951 1,584

ηwh (water heating efficiency) % 108 106 108 106

Qelec (Daily electricity consumption) kWh 4,500 7,426 4,500 7,426

Water heating energy efficiency class -

Cold climate AEC (Annual electricity consumption) kWh 1,366 1,366 2,260 1,366 2,260

ηwh (water heating efficiency) % 75

Qelec (Daily electricity consumption) kWh 6.454 6.454 10.520 6.454 10.520

Warm climate AEC (Annual electricity consumption) kWh 940 940 1,436 940 1,436

ηwh (water heating efficiency) % 109 109 117 109 117

Qelec (Daily electricity consumption) kWh 4.513 4.513 6.766 4.513 6.766

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 5.90 (2) / 6.00 (1) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

COP 5.10 (1) / 3.65 (2) 3.50 (2) / 4.85 (1) 3.50 (2) / 4.60 (1)

Pump Type Grundfos UPM3K 25-75

CHBL

-

Nominal ESP unit Heating kPa 66.0 (1) / 65.0 (2) 57.4 (1) / 58.1 (2) 38.7 (2) / 42.7 (1)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 12.3 (1) / 13.2 (2) 16.9 (2) / 17.2 (1) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater Yes

Low-temperature heat pump No

Supplementary heater integrated No

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 39

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSH04P30DA/

ERGA04DVAEHSH08P30DA/

ERGA06DVAEHSH08P50DA/

ERGA06DVAEHSH08P30DA/

ERGA08DVAEHSH08P50DA/

ERGA08DVA

• Heating • ERGA04-08DVA 59

Page 62: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

60

2 Specifications

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSHB04P30DA

/ERGA04DVAEHSHB08P30DA

/ERGA06DVAEHSHB08P50DA

/ERGA06DVAEHSHB08P30DA

/ERGA08DVAEHSHB08P50DA

/ERGA08DVA

Space heating Average climate water outlet 55°C

General SCOP 3.26 3.25 3.27

Annual energy consumption

kWh 3,806 4,456 4,731

ηs (Seasonal space heating efficiency)

% 127 128

Prated at -10°C kW 6 7 8

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

Cdh (Degradation heating) 1.0

COPd 1.97 1.98 198.00

Pdh kW 5.3 5.9

PERd % 79.0

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 3.23 3.16 3.18

Pdh kW 3.3 3.9 4.1

PERd % 129.0 126.0 127.0

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 4.40 4.49 4.54

Pdh kW 3.0

PERd % 176.0 180.0 182.0

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 6.10 6.16

Pdh kW 3.3 3.7

PERd % 244.0 246.0

Tol (temperature operating limit)

COPd 1.37 1.43

Pdh kW 4.0 4.5

PERd % 55.0 57.0

TOL °C -10

WTOL °C 55

Tbiv (bivalent temperature)

COPd 1.97 2.12 2.18

Pdh kW 5.3 6.1 6.4

PERd % 79.0 85.0 87.0

Tbiv °C -7 -6

Cold climate water outlet 55°C

General Annual energy consumption

kWh 4,468 5,325 7,066

ηs (Seasonal space heating efficiency)

% 107 108 109

Prated at -22°C kW 5 6 8

Warm climate water outlet 55°C

General Annual energy consumption

kWh 1,660 1,858 1,983

ηs (Seasonal space heating efficiency)

% 148 158 159

Prated at 2°C kW 5 6

• Heating • ERGA04-08DVA

Page 63: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Space heating Average climate water outlet 35°C

General SCOP 4.48 4.47 4.56

Annual energy consumption

kWh 2,766 3,233 3,625

ηs (Seasonal space heating efficiency)

% 176 179

Prated at -10°C kW 6 7 8

Seasonal space heating eff. class

A++

A Condition (-7°CDB/-8°CWB)

COPd 2.90 2.86 2.77

Pdh kW 5.5 6.0 7.0

PERd % 116.0 114.0 111.0

B Condition (2°CDB/1°CWB)

Cdh (Degradation heating) 1.0

COPd 4.33 4.25 4.35

Pdh kW 3.3 3.9 4.2

PERd % 173.0 170.0 174.0

C Condition (7°CDB/6°CWB)

Cdh (Degradation heating) 1.0

COPd 6.19 6.30 6.49

Pdh kW 3.2 3.3

PERd % 248.0 252.0 260.0

D Condition (12°CDB/11°CWB)

Cdh (Degradation heating) 1.0

COPd 7.78 8.52

Pdh kW 3.3 3.9

PERd % 311.0 341.0

Tol (temperature operating limit)

COPd 2.56 2.49 2.41

Pdh kW 5.2 6.0 6.9

PERd % 102.0 100.0 96.0

TOL °C -10

WTOL °C 35

Tbiv (bivalent temperature)

COPd 2.90 3.07 2.66

Pdh kW 5.5 6.1 7.5

PERd % 116.0 123.0 106.0

Tbiv °C -7 -6 -8

Cold climate water outlet 35°C

General Annual energy consumption

kWh 3,230 3,749 5,052

ηs (Seasonal space heating efficiency)

% 150 155 153

Prated at -22°C kW 5 6 8

Qhe Annual energy consumption (GCV)

Gj -

Warm climate water outlet 35°C

General Annual energy consumption

kWh 1,139 1,276 1,437 -

ηs (Seasonal space heating efficiency)

% 241 248 257 -

Prated at 2°C kW 5 6 7 -

Space heating general Air to water unit Rated airflow (outdoor) m³/h 2,280 27,770 2,770

Other Capacity control Inverter

Poff (Off mode) kW 0.010

Psb (Standby mode) kW 0.010

Pto (Thermostat off) kW 0.010

Integrated supplementary heater

Type of energy input Electrical

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSHB04P30DA

/ERGA04DVAEHSHB08P30DA

/ERGA06DVAEHSHB08P50DA

/ERGA06DVAEHSHB08P30DA

/ERGA08DVAEHSHB08P50DA

/ERGA08DVA

• Heating • ERGA04-08DVA 61

Page 64: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

2

62

2 Specifications

Notes

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

Domestic hot water heating

General Declared load profile L XL L XL

Heat up time from 10°C to 50°C min 91 158 91 158 158

Function to fix water heating during off peak hours

Yes

Average climate AEC (Annual electricity consumption) kWh 951 1,541 951 1,541

ηwh (water heating efficiency) % 108 109 108 109

Qelec (Daily electricity consumption) kWh 4,500 7,251 4,500 7,251

Water heating energy efficiency class - A - A -

Cold climate AEC (Annual electricity consumption) kWh 1,366 1,852 1,366 1,852

ηwh (water heating efficiency) % 75 90 75 90

Qelec (Daily electricity consumption) kWh 6.454 8.665 6.454 8.665

Warm climate AEC (Annual electricity consumption) kWh 940 1,343 940 1,343

ηwh (water heating efficiency) % 109 125 109 125

Qelec (Daily electricity consumption) kWh 4.513 6.346 4.513 6.346

Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 5.90 (2) / 6.00 (1) 7.50 (1) / 7.80 (2)

Power input Heating Nom. kW 0.850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)

COP 5.10 (1) / 3.65 (2) 3.50 (2) / 4.85 (1) 3.50 (2) / 4.60 (1)

Pump Type Grundfos UPM3K 25-75

CHBL

-

Nominal ESP unit Heating kPa 66.0 (1) / 65.0 (2) 57.4 (1) / 58.1 (2) 38.7 (2) / 42.7 (1)

Water side Heat exchanger

Water flow rate Heating Nom. l/min 12.3 (1) / 13.2 (2) 16.9 (2) / 17.2 (1) 21.5 (1) / 22.4 (2)

General Supplier/Manufacturer details

Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

Name or trademark Daikin Europe N.V.

Product description Air-to-water heat pump Yes

Brine-to-water heat pump No

Heat pump combination heater Yes

Low-temperature heat pump No

Supplementary heater integrated No

Water-to-water heat pump No

LW(A) Sound power level (according to EN14825)

Indoor dB(A) 39

LW(A) Sound power level (according to EN14825)

Outdoor dB(A) 58 60 62

Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825

CONNECTABLE INDOOR UNITS

2-1 Capacity and Power inputEHSHB04P30DA

/ERGA04DVAEHSHB08P30DA

/ERGA06DVAEHSHB08P50DA

/ERGA06DVAEHSHB08P30DA

/ERGA08DVAEHSHB08P50DA

/ERGA08DVA

• Heating • ERGA04-08DVA

Page 65: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

2

• Outdoor Unit • ERGA04-08DVA

2 Specifications

Notes

(1) Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

2-2 Technical Specifications ERGA04DVA ERGA06DVA ERGA08DVA

Dimensions Unit HeightxWidthxDepth mm 740x884x388

Weight Unit kg 58.5

Compressor Quantity 1

Type Hermetically sealed swing compressor

Operation range Cooling Min.~Max. °CDB 10~43

Domestic hot water Min.~Max. °CDB -25~35

Refrigerant Type R-32

GWP 675.0

Charge TCO2eq -

kg 1.50

Control Expansion valve

Sound power level Heating Nom. dBA 58 (1) 60 (1) 62 (1)

Cooling Nom. dBA 61 (1) 62 (1)

Sound pressure level Heating Nom. dBA 44 (1) 47 (1) 49 (1)

Cooling Nom. dBA 48 (1) 49 (1) 50 (1)

2-3 Electrical Specifications ERGA04DVA ERGA06DVA ERGA08DVA

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1N~/50/230

Current Recommended fuses A 16

• Heating • ERGA04-08DVA 63

Page 66: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

3

64

3 Combination table3 - 1 Combination Table

ERGA04-08DV

Kit availability for outdoor units*RGA04DAV3* *RGA06DAV3* *RGA08DAV3*

EKDP008D Drain pan kit o o oEKDPH008CA Drain pan heater o o oEKFT008D Feet kit o o oEKLN08A1 Low noise kit o o o

NOTES

1. When installing ·EKHDP008D· units in heavy snowfall areas, also install option kit ·EKDPH008CA·.

3D111531C

• Heating • ERGA04-08DVA

Page 67: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

4

• Outdoor Unit • ERGA04-08DVA

4 Capacity tables4 - 1 Cooling Capacity Tables

��������� ��� ���� ������ ���� ������ ���� ������ ���� ������ ���� ������ ���� ������

� ���� ���� ���� ���� ���� ���� ��� ���� ��� ���� ���� ������ ���� ��� ��� ��� ���� ���� ���� ���� ��� ���� ��� ������ �� ���� �� ���� ���� ���� ��� ���� ���� ���� �� ������ ��� ���� ��� ���� ��� ���� ��� ���� ��� ��� ��� ������ ��� ��� ��� ���� �� ���� ���� ��� ���� ���� ��� ������ �� ���� ���� ��� ��� ���� �� ���� ���� ���� ���� ����� ��� ���� ��� ���� �� ���� ���� ��� �� ��� ���� ����� ���� ���� ��� ���� ��� ���� �� ���� ���� ��� �� ����� ��� ���� ���� ��� �� ���� ��� ���� ��� ��� ���� ����� ��� ��� ��� ���� ���� ���� ��� ���� ���� ��� ���� ����� ��� ���� ���� �� ��� ���� ���� ���� ���� ��� ���� ����� ����� ���� ���� ���� ���� ���� ���� ���� ��� ��� ���� ���� ��� ��� ���� ���� ��� ��� �� ���� ���� ���� ���� ������ ��� �� ���� ���� ���� ���� ��� ���� ���� ���� ��� ������ ���� ���� ���� ��� ���� ���� �� ��� ��� ���� ��� ������ ���� ��� ��� ��� ���� ���� ���� ��� ��� ��� ���� ������ ��� ��� ����� ���� ��� ��� ���� ���� ��� ��� ���� ������ ���� ��� ���� ���� ����� ��� ��� ���� �� ��� ���� ���

�������

� ��������������������������������������������������� ���!������!�������"#������$% %��������������������������������������������������� ���!������!�������"#������&' &�(���������� ��)�������������������!������!����!�������� �������!�����)������������������*������!�������"#������$+," +��-����(������-���������������������./ 0+, +��-����(��������!�� ���������������./ 01��2 3�2����������������*�4%�5)������6�7���8

��� ���

���������������

�������������!������� ���!��!�"#���������!�-���!������)����!�(�����������91�7��:�/ $ ��������-���� ���������2�������������!�2���(�/ ����-����(����������������$

%��������������� �������������!������� ���!��!�"#���������!�-���!�����)����!�(�����������91�7��:�/ $

&�(��������&�(���������� ��)�������������������!������!����!�������� �������!�����)������������������*������!�������"#������$

�� ��1)�������������!��)����(�������������-���!�����;����!�� ��������;$1)�������������!��)����(���������������������������������$

�������������� ���!���"#

�� �� �� �� $� $�

%&'(

�$%

%&'(

�)%

%&'(

��%

����������

• Heating • ERGA04-08DVA 65

Page 68: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

4

66

4 Capacity tables4 - 2 Heating Capacity Tables

������������ *���� ������ *���� ������ *���� ������ *���� ������ *���� ������ *���� ������

+�� ��� ��� ��� �� �� � ���� ��� ���� ����+�� �� ���� ��� �� �� ��� ��� ��� � ���� � ����+� ���� ��� ���� ��� ���� ��� ��� ��� ���� �� ��� ����+� ��� ���� ���� ���� ��� ���� ���� ��� ���� �� �� ���� ���� ���� ���� ��� ��� ���� ���� ��� ���� ���� ��� ���� �� ���� ��� ���� ���� ��� ��� ���� ���� ��� ��� ����� ���� ���� ���� ���� ���� ��� ��� ���� ���� ���� ���� ������ ���� ��� ���� ���� ���� ���� ���� ���� ���� ��� ���� ������ ���� ���� ��� ���� ��� ��� ���� ���� ��� ���� ��� ���+�� ���� ��� ��� ���� ���� ��� ���� ��� ���� ���+�� ���� ��� ��� ��� ��� ��� ���� ��� ���� �� ���� ���+� ��� ���� ��� ���� ��� ��� �� ��� ���� ��� ���� ���+� ��� ���� ��� ���� ��� ���� ��� ���� ���� ���� ��� ��� ��� ��� ��� ���� �� ���� ��� ���� ���� ��� ��� ���� ���� ���� ���� �� ���� ���� ���� ���� ���� ��� ��� ������ ���� ��� ���� ���� ��� ���� ��� ��� �� ���� ��� ����� ��� ���� ���� ��� ��� ��� ��� ���� ��� ���� ���� ������ ���� ���� ��� ���� ��� ���� ���� ���� ���� �� ��� ����+�� ��� ��� ���� ���� ���� ���� ��� ���� ��� ����+�� ���� ���� ���� ���� ��� ��� ���� ���� ���� ���� ��� ����+� ��� �� ��� ���� ��� ��� ��� ���� ��� ���� ���� ���+� ���� ���� ��� ��� �� ���� ��� ���� ���� �� ���� ����� ��� ���� ��� ���� ��� ��� ��� ���� ���� ���� ��� ���� �� ���� ��� ��� ��� ���� ��� ��� ���� ���� ��� ����� �� ��� ��� ���� ��� ���� ��� ���� ��� ���� ���� ����� ��� ��� ���� ��� ���� ���� ���� ��� ��� ���� ���� ������ ���� ���� ���� �� ���� ���� ���� ���� �� ���� ���� ����

������������ *���� ������ *���� ������ *���� ������ *���� ������ *���� ������ *���� ������

+�� ��� ��� ��� �� �� ��� ��� ���� �� ����+�� ���� ��� �� �� ���� �� ���� ��� ��� ����+� ���� ��� �� ���� ���� ��� ���� ��� ���� ��� ��� ���+� ��� ��� ���� ��� ���� ��� ��� ��� ���� ��� ��� ���� ��� ���� ���� �� ���� ��� ��� ���� ��� ��� ���� ���� �� ���� ��� ���� ���� ��� ��� ���� ���� ��� ��� ����� ���� ���� ���� ���� ���� ��� ��� ���� ���� ���� ���� ������ ���� ��� ���� ���� ���� ���� ���� ���� ���� ��� ���� ������ ���� ���� ��� ���� ��� ��� ���� ���� ��� ���� ��� ���+�� ��� ���� ��� ���� ���� ��� ��� ��� ���� ���+�� ��� ���� �� ��� ��� ���� �� ��� ��� ��+� ���� ���� ��� ��� �� �� �� ���� ��� �� ���� ��+� ��� ���� ���� ���� ���� �� �� ��� ��� ���� �� ���� ���� ���� ���� ���� �� ��� ���� ��� ��� ���� �� ���� ���� ���� ���� �� ���� ���� ���� ���� ���� ��� ��� ������ ���� ���� ���� ���� ���� ���� ��� ��� �� ���� ��� ����� ���� ��� ��� ��� ��� ��� ��� ���� ��� ���� ���� ������ ���� ���� ��� ���� ��� ���� ���� ���� ���� �� ��� ����+�� ���� ���� ��� ���� ��� ���� ��� ��� ��� ���+�� ���� ���� ���� ��� ��� ���� ���� ���� ��� ���+� ���� ���� ���� ���� ��� ��� ���� ���� ���� ��� ���� ��+� ��� ���� �� ���� ��� ���� ���� ���� ��� ���� ���� ����� ��� ���� �� ���� ��� ��� �� ���� ��� ���� �� ���� �� ���� ��� ��� ��� ���� ��� ��� ���� ���� ��� ����� �� ��� ��� ���� ��� ���� ��� ���� ��� ���� ���� ����� ��� ��� ���� ��� ���� ���� ���� ��� ��� ���� ���� ������ ���� ���� ���� �� ���� ���� ���� ���� �� ���� ���� ����

������� � ��������������������������������������������������� ���!������!�������"#������$% %��������������������������������������������������� ���!������!�������"#������&' &�(���������� ��)�������������������!������!����!�������� �������!�����)������������������*������!�������"#������$+," +��-����(������-���������������������./ 0+, +��-����(��������!�� ���������������./ 01��2 3�2����������������*�4%�5)������6�7���8

��� ��� ���������������

�������������!������� ���!��!�"#���������!�-���!������)����!�(�����������91�7��:�/ $ ��������-���� ���������2�������������!�2���(�/ ����-����(����������������$

%��������������� �������������!������� ���!��!�"#���������!�-���!�����)����!�(�����������91�7��:�/ $

&�(��������&�(���������� ��)�������������������!������!����!�������� �������!�����)������������������*������!�������"#������$

�� ��1)�������������!��)����(�������������-���!�����;����!�� ��������;$1)�������������!��)����(���������������������������������$

%&'(

��%

%&'(

��%

%&'(

�)%

%&'(

�)%

%&'(

�$%

%&'(

�$%

����

��������,-�"�� ���!���"#�+���"- .�"-/�0���-

��������,-�"�� ���!���"#�+�!-���0���-1

�� �� $� $� �� ��

�� �� $� $�

����������

• Heating • ERGA04-08DVA

Page 69: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

4

• Outdoor Unit • ERGA04-08DVA

4 Capacity tables4 - 3 Certification Programs

����������

�������� �������� �������� �������� �������� ������������ �� ��� �� ��� �� ��� �� ��� ���� �� ��� �� ��� �� ��� �� ������� ���� ���� ���� ���� ���� ���� ���� ���� ���� ���� �������� � � ��� ���! ��� ���! � ! �� ! ���� � � ��� ���! ��� ���! � ! �� ! �� � � ��� ���� ���� ���� ��� ���� �� � � ��� ���� ���� ���� ��� ����!�� � � ��� ���� ���� � � ���� ��� !�� � � ��� ���� ���� � � ���� ���" �"� � � ���� ��� ���� !�#� ���� !� � " �"� � � ���� ��� ���� !�#� ���� !� � �� �� �� ���� ��� ��#� ��� ��� ��� �� �� �� ���� ��� ��#� ��� ��� ���!�� �� �� ��!� !��� ���� !��� ���� !� � !�� �� �� ��!� !��� ���� !��� ���� !� �" �"� �� �� ��� !��� ���� !�� ���� !�!� " �"� �� �� ��� !��� ���� !�� ���! !�!� �� � �� ��#� !��� ���� !� � ��� !� � �� � �� ��#� !��� ���� !� � ��� !� �" �"� � �� ��!� ���� ���� ���� ���� �� � " �"� � �� ��!� ���� ��#� ���� ���� �� �

��������� ��������� ������������� � �� �� � �� � �� ����� ���� ���� ���� ���� ����� ! �� ���� ��#� ��#� ���� ��!� ����� �! ��� ��� ��� �� ��� ���

$%��&'(�� �)�*+,-./�0�/+*%.�)�(12)3.�//&23+,-.*&. 4.������� �&&'+,-./�0�/+*%�.�)�(12)3.�//&23+,-.*&. 4.�����5���� � �&)66+/+),*.&6.�)26&2��,/)� ,)2-%.)66+/+),/%.2�*+&.�//&23+,-.*&. 4.�����5 �� ,*)2+,-.7�*)2./&,3),()2.*)�0)2�*12).������� �)�8+,-.7�*)2./&,3),(&2.*)�0)2�*12).���� � ,*)2+,-.7�*)2.)8�0&2�*&2.*)�0)2�*12).������ �)�8+,-.7�*)2.)8�0&2�*&2.*)�0)2�*12).�������� ���+),*.*)�0)2�*12).���.�9��9�

��*)3.3�*�.6&2./)2*+6+/�*+&,.02&-2���)(.".:)�*+,-.�&3) ��*)3.3�*�.6&2./)2*+6+/�*+&,.02&-2���)(.".:)�*+,-.�&3)

��*)3.3�*�.6&2./)2*+6+/�*+&,.02&-2���)(."./&&'+,-.�&3)

� ���� �

• Heating • ERGA04-08DVA 67

Page 70: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

5

68

5 Dimensional drawings5 - 1 Dimensional Drawings

���

��� ���

��

���������������� ����

���

�����

����������

�������������

���������������������������������

��������� ��

���������� ��

�������� ��

��������� ������� ��

������������������� ���������

�!���������"�"�

#�������"�"�

$�"������� %�����������&��������������

��

��

��

��

��

��

��

��

��

��

��

��

�������������� �����������������

������ � ������������� ��������

������� �������� ��������� ������������

���

������

���

���

������

���

���

���

���

���

���

��

���

��

��

�� ��������

��

��

�'�( �)*����� ����

���� ���

• Heating • ERGA04-08DVA

Page 71: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

6

• Outdoor Unit • ERGA04-08DVA

6 Centre of gravity6 - 1 Centre of Gravity

���

��� ���

��������

����� ����

• Heating • ERGA04-08DVA 69

Page 72: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

7

70

7 Piping diagrams7 - 1 Piping Diagrams

M

����

���������� �������������

�������

�����

����� �����

���������������

��� ��� ���������������

����

���������

���������

��������������

��������������������� �����

�������

�������

����������

�� �����������������

�������������

����������������

�������!����� ��������������

"#��$������

% �������

&'()&���

&'()&���

&'()&���

&'()&���

&*+('&��� &*+('&���

&*+('&���

���������

&"()&���

&"()&���

&,("&���

&,("&���

&,("&���

&,("&��� &'()&���

&'()&��� �������$��-��&.&

&"()&���

�������

�������������� �

&*/(0&��� &0(/&���

&*+('&���

% �������

&*/(0&���

��� ����

�������$��-��&+&

�������$��-��&*&

%���� �����

��������1

��������

����� ����

• Heating • ERGA04-08DVA

Page 73: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

8

• Outdoor Unit • ERGA04-08DVA

8 Wiring diagrams8 - 1 Wiring Diagrams - Single Phase

NOTES

When operating, do not short-circuit protection device(s) S1PH.Refer to the combination table and the option manual for how to connect the wiring to

3. Colours: BLK: Black, RED: Red, BLU: Blue, WHT: White, GRN: Green, YLW: Yellow.

LEGEND

Part n° DescriptionAL* ConnectorC* CapacitorDB*DC* ConnectorDP* ConnectorE* ConnectorF1U Fuse T 6,3 A 250 VFU1, FU2 Fuse T 3,15 A 250 VFU3 Fuse T 30 A 250 VH* ConnectorIPM* Intelligent power moduleL ConnectorLED 1~5 Indication lampLED A Pilot lampL* ReactorM1C Compressor motorM1F Fan motorMR* Magnetic relayN ConnectorPCB1 Printed circuit board (main)PCB2 Printed circuit board (service)PS Switching power supplyQ1L Thermal protectorQ1DI # Earth leakage circuit breakerQ* Insulated gate bipolar transistor

(IGBT)R1T Thermistor (air)R2T Thermistor (heat exchanger)R3T Thermistor (discharge)RTH2 ResistorS ConnectorS1PH High pressure switchS20~S02 ConnectorSA1 Surge arrestorSHMSW* SwitchU, V, W ConnectorV3, V4, V401 VaristorX*A ConnectorX*M Terminal stripY1E Electronic expansion valveY1S Solenoid valve (4-way valve)Z*CZ*F

# : Field supply* Optional

: Connection: Main terminal: Earth wiring: Field supply

: Option: Switch box: PCB

: Wiring depending on

model : Protective earth

: Field wire

INDOOR

Connection diagram

OUTDOOR

• Heating • ERGA04-08DVA 71

Page 74: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

9

72

9 Sound data9 - 1 Sound Pressure Spectrum - Cooling

���� ��

�������

������� ������� �������

4&*)(�5 ��*�.+(.8�'+3.�*.62)).6+)'3./&,3+*+&,5

;)�(12)3.+,.�.()�+"�,)/:&+/./:���)2!5 ��*�.+(.8�'+3.�*.,&�+,�'.&0)2�*+&,./&,3+*+&,55 39�.<.�"7)+-:*)3.(&1,3.02)((12).')8)'.=�.(/�').�//&23+,-.*&.> �?5�5 �)6)2),/).�/&1(*+/.02)((12).�.39.<.!�.@���5 >6.*:).(&1,3.+(.�)�(12)3.1,3)2.�/*1�'.+,(*�''�*+&,./&,3+*+&,(�.*:).�)�(12)3.8�'1).7+''.�)

:+-:)2.31).*&.),8+2&,�),*�'.,&+().�,3.(&1,3.2)6')/*+&,(5

;)�(12+,-.'&/�*+&,.=3+(/:�2-).(+3)?

NR0 NR5 NR10 NR15NR20

NR25

NR30

NR35NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

10

20

30

40

50

60

70

10

15

20

25

30

35

40

45

50

55

60

65

70

63 125 250 500 1000 2000 4000 8000 dBA

NR0 NR5 NR10 NR15NR20

NR25

NR30

NR35NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

10

20

30

40

50

60

70

10

15

20

25

30

35

40

45

50

55

60

65

70

63 125 250 500 1000 2000 4000 8000 dBA

NR0 NR5 NR10 NR15NR20

NR25

NR30

NR35

NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

10

20

30

40

50

60

70

10

15

20

25

30

35

40

45

50

55

60

65

70

63 125 250 500 1000 2000 4000 8000 dBA

�/*�8).��,3./),*2).62)A1),/%.��B��/*�8).��,3./),*2).62)A1),/%.��B��/*�8).��,3./),*2).62)A1),/%.��B�

$&1,

3.02)((12).')8)'.�39

$&1,

3.02)((12).')8)'.�39

$&1,

3.02)((12).')8)'.�39

3,28Ft(1m)

4,92Ft

(1,5m)

� ������

• Heating • ERGA04-08DVA

Page 75: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

3

9

• Outdoor Unit • ERGA04-08DVA

9 Sound data9 - 2 Sound Pressure Spectrum - Heating

����� �����������

������� ������� �������

4&*)(�5 ��*�.+(.8�'+3.�*.62)).6+)'3./&,3+*+&,5

;)�(12)3.+,.�.()�+"�,)/:&+/./:���)2!5 ��*�.+(.8�'+3.�*.,&�+,�'.&0)2�*+&,./&,3+*+&,55 39�.<.�"7)+-:*)3.(&1,3.02)((12).')8)'.=�.(/�').�//&23+,-.*&.> �?5�5 �)6)2),/).�/&1(*+/.02)((12).�.39.<.!�.@���5 >6.*:).(&1,3.+(.�)�(12)3.1,3)2.�/*1�'.+,(*�''�*+&,./&,3+*+&,(�.*:).�)�(12)3.8�'1).7+''.�).

:+-:)2.31).*&.),8+2&,�),*�'.,&+().�,3.(&1,3.2)6')/*+&,(5

;)�(12+,-.'&/�*+&,.=3+(/:�2-).(+3)?

NR0 NR5 NR10 NR15NR20

NR25

NR30

NR35NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

10

20

30

40

50

60

70

10

15

20

25

30

35

40

45

50

55

60

65

70

63 125 250 500 1000 2000 4000 8000 dBA

NR0 NR5 NR10 NR15NR20

NR25

NR30

NR35NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

10

20

30

40

50

60

70

10

15

20

25

30

35

40

45

50

55

60

65

70

63 125 250 500 1000 2000 4000 8000 dBA

NR0 NR5 NR10 NR15NR20

NR25

NR30

NR35

NR40

NR45

NR50

NR55

NR60

NR65

NR70

NR75

10

20

30

40

50

60

70

10

15

20

25

30

35

40

45

50

55

60

65

70

63 125 250 500 1000 2000 4000 8000 dBA

�/*�8).��,3./),*2).62)A1),/%.��B��/*�8).��,3./),*2).62)A1),/%.��B��/*�8).��,3./),*2).62)A1),/%.��B�

$&1,

3.02)((12).')8)'.�39

$&1,

3.02)((12).')8)'.�39

$&1,

3.02)((12).')8)'.�39

3,28Ft(1m)

4,92Ft

(1,5m)

� �������

• Heating • ERGA04-08DVA 73

Page 76: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

• Outdoor Unit • ERGA04-08DVA

10

74

10 Operation range10 - 1 Operation Range

���

��

��

����

��

����

��

��

��

��

��

��

��

�� ��

��

����������������������

������������������������������������

�������������������������������������������������������������

������������������������������������������������

���!���������

������

������������������ ��������������������������������������

������

"������������������������

�������������� ������������������������������������������������������������������������������������������

�������

���

�����

���

������������� ��

������������

������������� ��

������������

���������������� ������

���������������� ������

����������������������������� ��������������������������������� ���

��

� ��

�� ��

�������������� ������������������������� ����� ��!"����#��� ������������� ����������������� ���$

��� � ����������� �%���������� ����� ����&��������'������� � ��������� ('������ �������(��������)�����&���������������������� �����

*��+�,� ����(���������� � �-�.���� ���/�)��0���%��)��1��� 2��3����� ��4��� ���5�� �'��6��& '��7 �(� ��7���� �� ��*�� '��8�� ���0�� �� ��9�%� ��9��( 2� ��9������:

����

���������

��

�� ����

��

���������������� ������

������������� ��

������������

������

����

������������� ������������ ������������ ����������� ��� ������

� �������������������������������� ���� �����������������

������������� �������

��

����������� ���� �������� ��������

! ������������ ���� ����� ���"���� ������������������� "������������

(*)

(*)

#������ ����� �$������������ ������ "���� ��� ������������ ������

�����������%� ����������������� ���������������& ����������������

�"����� ��� ��������������'()*+,������� ��� ������ ����� ����� ������

����������� ����������������� �

��

�"����� ��� ��������������'�-).+,������ ��� ������������ �

��� ����������������������� ����� ������ �����

, ����� �� "������#�/0����������!�/01����� ������

�� �� �� �� ��

(1)(2)

���1�/01����� ������� ���

���������

• Heating • ERGA04-08DVA

Page 77: Heating Technical Data ERGA04-08DVA - selizobrazevanja · 2020. 4. 23. · % 150 155 153 Prated at -22°C kW 5.0 6.0 8.0 Qhe Annual energy consumption (GCV) Gj - Warm climate water

Daikin Europe N.V. Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR OostendeDaikin Europe N.V. participates in the Eurovent CertifiedPerformance programme for Liquid Chilling Packagesand Hydronic Heat Pumps, Fan Coil Units and VariableRefrigerant Flow systems. Check ongoing validity of cer-tificate: www.eurovent-certification.com

EEDEN18 03/18

The present leaflet is drawn up by way of information only and does not constitute an offer bindingupon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of itsknowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fit-ness for particular purpose of its content and the products and services presented therein. Specifica-tions are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arising from or related to the use and/or inter-pretation of this leaflet. All content is copyrighted by Daikin Europe N.V.