heated hoses - nordic sensors industrial inc. · ontario: 61 division street guelph, ontario n1h...

1
ONTARIO: 61 DIVISION STREET GUELPH, ONTARIO N1H 1R3 905-730-5295 [email protected] QUÉBEC: 1350 RUE NATIONALE TERREBONNE, QUÉBEC J6W 6M1 1-888-667-3421 [email protected] HEATED HOSES NSI's high-pressure hose has a smooth bore PTFE core overbraided with stainless steel for improved strength; • Two layers of fiberglass/silicone bedding insulation; • Fiberglass reinforced nichrome heating element; • 1/2" of a thermal insulation made of meta-aramid felt or silicone foam; • Moisture barrier rated at 130°C protects felt insulation; • Standard abrasion protection: polyester braid. Optional: water resistant jacket or metal braid; • Hard plastic or heat-shrink end caps (depending on hose size); • Standard fitting: 37° JIC female swivel on both ends. Optional: Male NPT or other fitting types on request; • Maximum recommended working temperature: 400°F/204°C (continuous); • Maximum working pressure: 5000 psi (at 72°F), 3000 psi (at 400°F); • Custom lengths are available; • Standard temperature sensor: Thermocouple Type J. Optional: RTD, thermistor, thermocouple of other types; • Standard electrical termination: 6 ft. lead cable with ground wire (AWG 18) fiberglass overbraided. Custom terminations are available on request; • Power supply: 115V or 230V. Custom voltage rating may be ordered; • Standard power rating: 35W or 70W per linear foot. Custom ratings are available on request.

Upload: others

Post on 02-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEATED HOSES - Nordic Sensors Industrial Inc. · ontario: 61 division street guelph, ontario n1h 1r3 905-730-5295 kelly.mccann@nordicsensors.com quÉbec: 1350 rue nationale terrebonne,

ONTARIO:61 DIVISION STREETGUELPH, ONTARION1H [email protected]

QUÉBEC:1350 RUE NATIONALETERREBONNE, QUÉBECJ6W [email protected]

HEATED HOSES

• NSI's high-pressure hose has a smooth bore

PTFE core overbraided with stainless steel for

improved strength;

• Two layers of fiberglass/silicone bedding insulation;

• Fiberglass reinforced nichrome heating element;

• 1/2" of a thermal insulation made of meta-aramid felt or

silicone foam;

• Moisture barrier rated at 130°C protects felt insulation;

• Standard abrasion protection: polyester braid. Optional: water resistant

jacket or metal braid;

• Hard plastic or heat-shrink end caps (depending on hose size);

• Standard fitting: 37° JIC female swivel on both ends. Optional: Male NPT

or other fitting types on request;

• Maximum recommended working temperature: 400°F/204°C

(continuous);

• Maximum working pressure: 5000 psi (at 72°F), 3000 psi (at 400°F);

• Custom lengths are available;

• Standard temperature sensor: Thermocouple Type J.

Optional: RTD, thermistor, thermocouple of other types;

• Standard electrical termination: 6 ft. lead cable

with ground wire (AWG 18) fiberglass

overbraided. Custom terminations are

available on request;

• Power supply: 115V or 230V. Custom

voltage rating may be ordered;

• Standard power rating: 35W or 70W per

linear foot. Custom ratings are available

on request.