heat pump & solar hybrid air...

16
Jiangsu Sunchi New Energy Co.,Ltd Add:Zhangnian Industrial Park,Huangtang Town, Danyang City,Jiangsu Province,China Tel:+86 511 86639068 Fax:+86 511 86622777-8078 Email:[email protected] Website:www.suntchenergy.com HEAT PUMP & SOLAR HYBRID AIR CONDITIONER HEAT PUMP & SOLAR HYBRID AIR CONDITIONER

Upload: vothuy

Post on 12-Mar-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Jiangsu Sunchi New Energy Co.,LtdAdd:Zhangnian Industrial Park,Huangtang Town, Danyang City,Jiangsu Province,ChinaTel:+86 511 86639068Fax:+86 511 86622777-8078Email:[email protected]:www.suntchenergy.com

HEAT PUMP &

SOLAR HYBRID

AIR CONDITIONER

HEAT PUMP &

SOLAR HYBRID

AIR CONDITIONER

Jiangsu Sunchi New Energy Co., Ltd. is a scientific and technological innovation-oriented enterprise which is specially engaged in researching, developing, manufacturing and marketing of solar air-conditioner, heat pump and solar water heater. For years, SUNCHI take the concept and objective of "quality first, service superior" and "sincere cooperation, green civilization". Meanwhile, SUNCHI execute ISO9001:2000 strictly and the products have passed many authorized attestations such as: ISO9001:2008, CE, 3C, TUV and SGS. SUNCHI is located in Danyang City Jiangsu Province with convenient transportation and covers an area of over 50,000㎡, and has over 300 employees with annual productivity of 180,000 sets. Take the quality as foundation and client's satisfaction as our aim, keep development and innovation ,work hard in the field of green, safe and energy saving solar energy, and build a brilliant future with you together.

SUNCHI GROUP

www.suntchenergy.com

01 02

CERTIFICATE PRODUCTION LINE

www.suntchenergy.com

03 04

EXHIBITION PROJECT

www.suntchenergy.com

05 06

COMMECIAL HEAT PUMP WATER HEATER

Model

Heating capacity

COP

Hot water yield (L/h)

Rated hot water temperature (℃)

Tiptop outlet water temp. (℃)

Inlet/outlet pipe size (mm)

Circulating water flow (m³/h)

Noise [dB(A)]

Power supply

Electric shock protection class

Waterproof grade

Rated input power (W)

Rated input current (A)

Maximum input power (W)

Maximum input current (A)

Operating ambient temperature (℃)

Unit size (mm)

Net weight (kg)

41,000

12

4.29

258

55

60

DN25

≥2.1

≤56

65,000

19

4.22

408

55

60

DN25

≥3.3

≤62

120,000

35

4.07

752

55

60

DN40

≥6.1

≤64

380-420V~/3PH/50Hz

I

IPX4

154,285

45

4.07

860

55

60

DN40

≥7.8

≤68

240,000

70

4.07

1500

55

60

DN50

≥12.1

≤68

358,200

105

4.06

2257

55

60

DN65

≥18.1

≤72

2800

4.7

3800

6.43

-10~45

680×680×860

100

Test Condition : Ambient temp.(DB/WB):20℃/15℃, Input/output water temp.:15℃/55℃.

4500

8.5

7000

11.7

-10~45

760×760×965

160

8600

14.8

15500

25

-10~45

1406×765×1050

295

11600

17.9

19900

28.7

-10~45

1406×765×1050

300

17200

34.6

24300

43.7

-10~45

2000×1100×1900

860

25800

39.2

36400

55.4

-10~45

2510×1030×2130

1300

Btu/h

kW

KFXRS-12Ⅱ KFXRS-19Ⅱ KFXRS-35Ⅱ KFXRS-45Ⅱ KFXRS-70Ⅱ KFXRS-105Ⅱ

The commercial series is designed for restaurant, school, factory etc. large hot water project. It normally equipped with bigger and more powerful compressors, larger heating capacity output to meet big heat consumption. ◆ Guarantee Safe: Complete isolation of water and electricity; LCD screen digital controller and full auto-matically; Automatic defrosting function included.

◆ High efficiency: Air exchanger (fins-coil) with hydrophilic coating, collecting the heat from the air and the electricity is only used to drive the compressor . Compared with the oil boiler can save over 70%.

◆ Greenness Environmental Protection: High efficiency compressor with R410A refrigerant guarantee fluoride-free emission; By using the clean energy air source and electricity, without environmental pollution as the oil, natural gas and other fossil fuels causing.

◆ All-weather Use: Normally running in windy, rainy and snowy , ensuring all day long hot water supply. Further more, the precise water temperature control system ensure a constant outlet water temperature .

◆ Durable: High quality compressor, four-way valve and other major parts from the world famous factories guarantee a longer lifespan than other kinds of water heater.

◆ Modular design available for compose to bigger system to meet any size of big heating capacity require-ments.

◆ General testing and operational test carried out for every unit before package in the factory.

www.suntchenergy.com

07 08

85℃ HIGH

TEMPERATURE

COMMERCIAL HEAT PUMP

Model

Heating capacity

Test Condition: Ambient temp.(DB/WB): 20℃/15℃, Input/output water temp: 15℃/55℃

Ambient temp.(High ) -(DB/WB): 20℃, Input/output water temp: 15℃/85℃

COP

Rated hot water temperature (℃)

Top outlet water temperature (℃)

Hot water yield (L/h)

Inlet/outlet pipe size (mm)

Circulating water flow (m³/h)

Noise [dB(A)]

Power supply

Electric shock protection class

Waterproof grade

Rated input power (W)

Rated input current (A)

Maximum input power (W)

Maximum input current (A)

Ambient temperature (℃)

Unit size (mm)

Net weight (kg)

Btu/h

kW

40,900

12

4.29

55

85

257

DN25

≥2.1

≤56

64,800

19

4.22

55

85

408

DN25

≥3.3

≤62

119,400

35

4.07

55

85

752

DN40

≥6.1

≤64

380-420V~/3PH/50Hz

I

IPX4

154,285

45

4.07

55

85

966

DN40

≥7.8

≤65

238,800

70

4.07

55

85

1500

DN50

≥12.1

≤68

358,200

105

4.06

55

85

2257

DN65

≥18.1

≤72

2800

4.7

3900

6.43

5~45

755×384×1240

100

4500

8.5

7200

11.7

5~45

760×760×965

160

8600

14.8

16500

25.2

5~45

1406×765×1050

293

11600

18.4

18500

29.5

5~45

1406×765×1050

300

17200

34.6

25500

43.7

5~45

2000×1100×1900

860

25800

39.2

36400

55.4

5~45

2510×1030×2130

1300

KFXRS-12Ⅱg KFXRS-19Ⅱg KFXRS-35Ⅱg KFXRS-45Ⅱg KFXRS-70Ⅱg KFXRS-105Ⅱg

The high temperature hot water heat pump for heating water temperature can reach up to 85 degrees, which greatly expanded the field of heat pump applications can be directly recycled from 20 to 55 low-grade waste heat resources, a system of 65 to 85 degree hot water for heating, saving a lot of primary energy, with very good energy-saving and environmental benefits.

Features:

◆ Equipped with high quality rotary compressor. ◆ LED indoor control panel with touching key. ◆ Can work with indoor thermostat. ◆ With auxiliary heater control output.◆ Can control circulation pump with anti-frozen function.◆ Auto-defrosting, reversible thermostatic expansion valve. ◆ Galvanized steel cabinet with powder painting in gray or white, strong and durable. ◆ With full protection functions including water flow, high/low pressure, phase order, over-current etc. ◆ Heating curve (Temperature compensation function) to adjust water temperature as per outdoor temperature. ◆ 85 degree hot water idea for hot oil storage project, beverage factory, breweries, restaurant kitchens sterilized, textile printing and dyeing industry etc.

www.suntchenergy.com

09 10

EVI COMMERCIAL HEAT PUMP This EVI heat pump is specially designed for chilly climate areas. Its core philosophy is to solve the users' house heating and hot water supply during the very cold climate. * Low-temperature Enhanced Vapour Injection compressor technology ( EVI ) guarantee a stable running even at -25℃.* Perfect protection design: anti-frost protection, high/ low pressure protection, water flow protection, high-temp protec-tion, etc., and automatic defrost function, assuring the system to run safely and efficiently even in hard conditions.* high quality and reliability: World-known brand components such as Japanese famous brand compressor, Emerson ALCO expansion valve, Siemens electric, etc.* Large heat exchanger extracting more heat energy from ambient air source--COP exceeds 4.0.* Running state display and error/fault self-checking.* Compact design, easy for installation.

Model

Heating capacity

COPRated hot water temperature (℃)Top outlet water temperature (℃)

Inlet/outlet pipe size (mm)Circulating water flow (m³/h)

Hot water yield (L/h)Noise [dB(A)]Power supply

Electric shock protection class Waterproof grade

Rated input power (W)Rated input current (A)

Maximum input power (W)Maximum input current (A)Ambient temperature (℃)

Unit size (mm)Net weight (kg)

40,90012

4.295560

DN25≥2.1257≤56

64,80019

4.225560

DN25≥3.3408≤62

380-420V~/3PH/50HzI

IPX4

119,40035

4.075560

DN40≥6.1752≤64

238,80070

4.075560

DN50≥12.11,500≤68

358,2001054.065560

DN65≥18.12,257

28004.7

39006.43

-25~45680*680*860

100

45008.5

720011.7

-25~45760*760*965

160

Test Condition: Ambient temp.(DB/WB): 20℃/15℃, Input/output water temp: 15℃/55℃Ambient temp.(Low ) -(DB/WB): -25℃, Input/output water temp: 15℃/55℃

860014.8

1650025.2

-25~451406*765*1050

293

2580039.2

3640055.4

-25~452510*1030*2130

1300

Btu/h

kW

KFXRS-12Ⅱd KFXRS-19Ⅱd KFXRS-35Ⅱd KFXRS-70Ⅱd KFXRS-105Ⅱd

1720034.6

2550043.7

-25~452000*1100*1900

860

www.suntchenergy.com

11 12

Model KFGRS-12Ⅱ KFGRS-19Ⅱ KFGRS-35Ⅱ KFGRS-45Ⅱ KFGRS-70Ⅱ KFGRS-105Ⅱ

Hot water capacity

Cooling capacity

Heating capacity

Test Condition: Cooling: Ambient temp.(DB/WB): 35℃/24℃, Water temp=(In/Out)12℃/7℃ Heating: Ambient temp.(DB/WB): 7℃/6℃, Hot Water temp=(In/Out)20℃/15℃

Hot water: Initial/Finial:15℃/55℃

kWBtu/hkW

Btu/hkW

Btu/h

1240,900

7.525500

8.127600258≥2.1

DN25≤56

1964,80012.5

4265013.2

45000408≥3.3

DN25≤62

35119,400

24.58350026.2

89300752≥6.1

DN40≤64

5560

380-420V~/3PH/50HzI

IPX4

45153,540

39133000

42143300

967≥7.8

DN40≤67

70238,800

51.2174600

55.61897001500≥12.1DN50≤68

105358,200

84286600

953241002257≥18.1DN65≤72

28004.7

38006.434.2924803.7733405.123.0226604.1237105.653.05

-10~45884×384×1360

107

45008.5

700011.74.2241506.3

55608.473.0140506.1556308.553.11

-10~45884×384×1360

175

860014.8

1550025

4.07776011.821079016.383.16848012.881179017.933.09

-10~451406×765×1050

314

1080016.4

1790027.24.17

1293019.652138032.483.01

1353020.562237033.883.11

-10~451406×765×1050

385

1720034.6

2430043.74.07

1679025.512334035.453.05

1853028.152576039.13

3 -10~45

2000×1100×1900885

2580039.2

3640055.44.06

3020045.894190064.522.78

3330050.324630070.332.85

-10~452510×1030×2130

1400

Hot water yield (L/h)Circulating water flow (m³/h)Inlet/outlet pipe size (mm)

Noise [dB(A)]Rated hot water temperature (℃)Top outlet water temperature (℃)

Power supplyElectric shock protection class

Waterproof grade Rated input power (W)Rated input current (A)

Maximum input power (W)Maximum input current (A)

COPRated input power (W)Rated input current (A)

Maximum input power (W)Maximum input current (A)

COPRated input power (W)Rated input current (A)

Maximum input power (W)Maximum input current (A)

COPOperating ambient temperature (℃)

Outdoor unit size (mm)Net weight (kg)

Hot Water

Cooling

Heating

The trinity heat pump system is mainly designed for providing hot water and heating or cooling function. Five running modes can be converted by the controller intelligently as follow:1. Single cooling; 2. Single heating; 3. Single hot water supplying; 4. Cooling & hot water supply; 5. Heating & hot water supplying.

TRINITY HEAT PUMP SYSTEM

www.suntchenergy.com

13 14

ALL IN ONE HEAT PUMP

The system adopts microcomputer control which can heat hot water according to the water temperature and time at any time, no need special person and users can set and adjust water temperature from 30℃ to 60℃, the easy operation save you too much bill and labor. The COP is as high as 400% all year, the only electricity consumed are 1/4 of traditional electric heaters adopts water & electricity isolation which can avoid electric shock, end gas and pollution integrated design which can be ever easier installation, no refrig-erant leak during install. We use polyurethane foam as insulation material which is good insulation to keep hot water warm. The hot water can only drop about 3 degree within 48 hours.

Model

Water tank capacity

Btu/h

KW

150 L

8,500

2.5

3.6

55

60

Ø6.35/9.52

200 L

12,000

3.5

3.92

55

60

Ø6.35/9.52

250 L

12,000

3.5

3.92

55

60

Ø6.35/9.52

694

3.2

868

3.9

893

4.06

1116

5.1

R134A

220V/1PH/50Hz

I

IPX4

DN15

≤52

DN15

≤54

DN15

≤54

-10~45

893

4.06

1116

5.1

63

Ø570×1340

Test Condition: Ambient temp.(DB/WB):20°C/15°C, Input/output water temp.=15°C/55°C

75

Ø570×1630

89

Ø640×1750

Heat Pump - Main Engine Data

COP

Rated hot water temperature (°C)

Tiptop outlet water temperature (°C)

Inlet/Outlet hole size (mm)

Inlet/Outlet pipe size (mm)

Noise [dB(A)]

Refrigerant

Power supply

Electric shock protection grade

Waterproof grade

Rated input power (W)

Rated input current (A)

Maximum input power (W)

Maximum input current (A)

Operating ambient temperature (°C)

Unit net weight (kg)

Unit dimension (mm)

Heating capacity

KXRS-2.5IZ/MF KXRS-3.5IZ/MF KXRS-3.5IZA/MF

www.suntchenergy.com

15 16

The second generation domestic heat pump water heater is made of water tank, heat pump and heat pipe solar collec-tor which combines utility power with solar energy together to get higher efficiency and more energy-saving.

Model

kW

Btu/h

4.2

14,300

5.32

90

5.2

17,700

5.31

112

55

60

220-240V~/1PH/50Hz

33 41

≤54 ≤55

I

IP×4

800×300×840

860×310×870

50

880×340×890

940×350×920

≤56

7.3

24,900

5.29

157

790

3.6

910

4.2

150

∮470×1530

530×530×1530

38/34

28/88

580×580×1660

45/40

28/80

-10~45

Test Condition: Ambient temp. (DB/WB):20°C/15°C,(800W/㎡ Effective sunshine)

730×730×1580

53/48

18/48

980

4.5A

1120

5.1

260

∮520×1600

1380

6.3

1580

7.2

300

∮670×1520

0.7MPa

Stainless steel

COP

Hot water yield (L/h)

Rated hot water temperature (°C)

Tiptop outlet water temperature (°C)

Power supply

Outdoor unit N.W. (kg)

Outdoor unit size (mm)

Outdoor unit packing size (mm)

Noise [dB(A)]

Electric shock protection class

Waterproof grade

Rated input power (W)

Rated input current (A)

Maximum input power (W)

Maximum input current (A)

Water tank capacity (L)

Water tank dimension (mm)

Water tank pressure

Heat exchanger coil

Water tank packing size (mm)

Water tank G.W. /N.W.(kg)

Loading container (20’/40’HQ)

Operating ambient temperature (°C)

Heating capacity

KFRS-4.2 IS KFRS-5.2 IS KFRS-7 .3IS

SOLAR HEAT PUMP WATER HEATER

www.suntchenergy.com

17 18

Swimming Pool Heat Pump applies titanium coil exchanger and heat pump technology which can move

heat from the surroundings to the pool water. The use of R410A refrigerant makes the unit in perfect

performance and more environmentally-friendly. It’s widely used in house and villa swimming pools. With

the high COP, the unit can save for at least 3/4 electricity energy for your family each month.

Model

Heating capacitykW

Btu/h

12

40,900

19

64,800

35

119,400

45

153,540

380-420V~/3PH/50Hz

I

IPX4

-10~45

Test Condition: Ambient temp.(DB/WB): 20/15℃; Input/output water temp.: 15/28℃;

Ambient temp. : -7~43℃; Normal type is plastic shell, stainless steel plate for operation;

70

238,800

105

358,200

≥2.1

100

680×680×860

≥3.3

160

760×760×965

≥6.1

293

1406×765×1050

≥7.8

379

1406×765×1050

≥12.1

860

2000×1100×1900

≥18.1

1300

2510×1030×2130

793

DN32

≤56

28

35

2350

3.57

3300

5.01

5.11

1,256

DN32

≤62

28

35

3730

5.67

5800

8.81

5.09

2,314

DN50

≤64

28

35

6900

10.48

9500

14.43

5.07

2,980

DN50

≤66

28

35

8870

12.21

12210

18.55

5.07

4,629

DN65

≤68

28

35

13700

20.82

19300

29.32

5.11

6,944

DN80

≤72

28

35

20100

30.54

26400

40.11

5.22

Hot

Water

Operating ambient temp. (℃)

Circulating water flow (m³/h)

Net weight (kg)

Dimension of outdoor unit (mm)

Power supply

Electric shock protection class

Waterproof grade

Hot water yield (L/h)

Water connection (mm)

Noise [dB(A)]

Rated water temp. (℃)

Max. water temp. (℃)

Rated input power (W)

Rated input current (A)

Maximum input power (W)

Maximum input current (A)

COP

KFCRS-12II KFCRS-19II KFCRS-35II KFCRS-45II KFCRS-70II KFCRS-105II

SWIMMING POOL HEAT PUMP

www.suntchenergy.com

19 20

◆ High Efficiency: this water heater collects the heat from the air and the electricity is only used to drive the compressor to pump up the heat from the air. saving 60%~80% of operation expense compared with traditional hot water facilities.◆Durable: this water heater has high quality compressor, super-thick anti-corrupted steel plate body and other high quality accessories make its lifespan much longer than other kinds of water heaters.◆Greenness Environmental Protection: R410 refrigerant guarantee fluoride-free emission.◆Guarantee Safe: complete isolation of water and electricity; LCD screen digital controller and full auto-matically.◆Comfortable: excellent SUS 304 stainless steel inner tank pressurized water tank pressure reaches 0.6Mpa-0.9Mpa.◆Convenient: this water heater is easy to install in many places, such as the garage, balcony, kitchen etc.◆All-weather Use: it's not affected by the windy, rainy and snowy weather.◆Wide Range of Application: villa, apartment, high-floor residence, business restaurant, hotel and multi-floor living building in country and village.

HOME USE WATER CIRCLE HEAT PUMP

Model

Heating capacityBtu/h

kW

10,000

3

3.7

65

55

65

DN20

≤52

12,000

3.5

3..8

75

55

65

DN20

≤52

17,000

5

3.8

108

55

65

DN20

≤55

220-240V~/1PH/50Hz

I

IPX4

24,000

7

3.8

150

55

65

DN20

≤56

30,000

9

3.8

190

55

65

DN25

≤58

810

3.68

1050

4.78

-10~45

930×280×520

37

150 200 260 300 300

920

4.20

1200

5.50

-10~45

930×280×520

40

Pressure water tank with copper coil Data

Test Condition: Ambient temp.(DB/WB):20°C/15°C, Input/output water temp.=15°C/55°C

1310

5.95

1700

7.70

-10~45

930×280×520

47

1840

8.36

2390

10.88

-10~45

1000×300×620

58

2360

10.3

3100

13.5

-10~45

1000×300×620

65

COP

Hot water yield ( L/h)

Rated hot water temperature (°C)

Tiptop outlet water temperature (°C)

Inlet/outlet pipe size (mm)

Noise [dB(A)]

Power

Electric shock protection class

Waterproof grade

Rated input power (W)

Rated input current (A)

Maximum input power (W)

Maximum input current (A)

Operating ambient temp. (°C)

Unit dimension (mm)

Net Weight (kg)

Suggestion water tank capacity (L)

KXRS-3.0XA KXRS-3.5XA KXRS-5.0XA KXRS-7.0XA KXRS-9.0XA

www.suntchenergy.com

21 22

MODULAR AIR-COOLED SCROLL CHILLER

23

This modular air-cooled heat pump air conditioner does not use any combustion process or energy to generate heat. It only uses little electricity to transfer the energy from air to effect heating and cooling, which are suitable for villas, hotels, factories, schools, salons, leisure centers etc. Modular design available for compose to bigger system to meet any size of big heating or cooling capacity requirements.

ModelProduct use

Cooling capacitykW

Btu/h

kW

Btu/h

66

225256

72

245734

100

341297

110

375427 finned coil type

380-420V~/3PH/50Hz

I

IPX4

7℃

45℃

-10℃~45℃Test Condition: Cooling: Ambient temp.(DB):35℃; Heating: Ambient temp.(DB/WB): 7℃/6℃

3.27

2/CopelandR22/2×10kg

R410A/2×8kg11.4

DN50

3/CopelandR22/3×10kg

R410A/3×8kg17.2

DN50

3.14

840

2120×1050×2150

2320×1150×2300

≤68

21.522

38.438.8282950

50.53.07

34.235

61.162

44.545.580

80.62.92

920

2120×1050×2150

970×470×1480

≤72

Heat exchangerPower supplyNet weight(kg)

Product dimension (mm)Package size (mm)

Noise dB(A)Electric shock protection class

Waterproof grade

CoolingHeatingCooling HeatingCooling HeatingCooling Heating

COP data-CoolingCooling output water temp

COP data-HeatingHeating output water temp

Compressor QTY /brand

Refrigerant

Circulating water flow(m3/h)Water pipe diameter

Working for ambient temperature

R22/R410A

Heating capacity

Rated input power (kW)

Rated input current (A)

Max input power (kW)

Max input current (A)

Cooling/Heatin

LSQWH20/MD50CF/LSQWH20/MD50AF LSQWH30/MD50CF/LSQWH30/MD50AF

www.suntchenergy.com

24

Integral ground / water source heat pump is a kind of new water cooled air conditioner, which uses surface

soil or solar energy stored in water bodies as cold and heat sources and combines terminal equipments

(fan coil unit, floor heaters, capillary) into an environmental friendly, energy saving, multi-function air condi-

tion system. In winter, low quality heat energy in water is taken out to supply indoor heating and air condi-

tioning. In summer, the indoor heat is taken out and released into the water to achieve the purpose of air

conditioning. This unit is suitable for water loop, groundwater and ground loop, would not be affected by

outside climate and can operate round-the-clock. Normally, 1kw input power can obtain the cold & heat

4KW above. Energy-saving is over 70% comparing with conventional air conditioning systems.

INTEGRAL GROUND/

WATER SOURCE AIR CONDITIONER

www.suntchenergy.com

25 26

Model R-3.1ⅠCT3 R-3.6ⅠCT3 R-5.2ⅠCT3 R-6.2ⅠCT3 R-7.2ⅡCT3 R-9ⅡCT2 R-11ⅡCT2 R-13ⅡCT2 R-16ⅡCT2 R-18ⅡCT2

Cooling capacity

Kcal/Hr

Btu/h

kW

Kcal/Hr

Btu/h

kW

2666

10577

3.1

3268

12966

3.8

630

30

730

30

980

30

1450

30

1600

30

2100

50

2100

50

2200

80

3100

80

33000

80

3096

12283

3.6

3870

15354

4.5

4472

17742

5.2

5160

20472

6

5332

21154

6.2

5848

23202

6.8

6192

24566

7.2

7482

29684

8.7

7740

30708

9

9890

39238

11.5

9460

37532

11

10836

42991

12.6

11180

44356

13

13330

52886

15.5

13760

54592

16

16340

64828

19

15480

61416

18

17200

68240

20

m3/h

Pa

type

QTY

kW

kW

A

m3/h

kPa

0.86

0.93

4

0.7

10

0.8

1020*512*385

450×332

292×292

375×518

70 75 95 98 108 127 140 148 157

1" female screw3/4" female screw

1/2" female screw

Test Condition: Cooling: ambient temp.(DB/WB): 27/19℃; Input/output water temp.: 30/35℃;

Heating: ambient temp.(DB/WB): 20/15℃; Input water temp: 20℃

163

1168*586*436

521×381

342×342

425×603

1270*635*487

572×432

430×430

476×648

1475*840*538

675×482

456×456

527×758

0.98

1.1

4.6

0.82

20

1.1

1.35

1.45

6.4

1.1

14

1.2

1.6

1.6

7.45

1.3

13

1.3

1.6

1.61

3.4

1.55

22

1.4

2.4

2.41

5.2

1.85

23

1.6

2.62

2.8

5.5

2.3

28

1.8

2.9

3.2

7.5

2.69

42

2.4

3.75

3.95

9.8

3.46

55

2.5

4.25

4.6

11

3.74

70

2.6

Heating capacity

Power supply 220V/1Ph/50Hz

rotor

1

380V/3Ph/50Hz

scroll

Circulating air

Static pressure

cooling

heating

L*W*H

L*W

L*W

L*W

mm

mm

mm

mm

kg

inch

inch

Rated current

water flow

water pressure drop

Refrigerant

Dimension

Air inlet size

Air outlet size

filter mesh size

Net weight

Inlet water pipe size

Drainpipe size

Rated powerinput

(R410A) kg

Compressor

The system driven by electricity and together with solar energy as an auxiliary power. The two kinds of energy work complementally in accordance with principles of fluid dynamics. It combines the absorption working system to compression system by using environmental-friendly media in cooling and heating on the basic of traditional.

SOLAR HYBRID AIR CONDITIONER

◆ Wall Mounted Type

Model No. KFR-26GW-TYN KFR-32GW-TYN KFR-35GW-TYN KFR-52GW-TYN KFR-72GW-TYNPower Supply 220-240VAC, 1PH, 50Hz/60Hz

Capacity

Noise

Cooling Btu/hW

Btu/hW

dB(A)dB(A) m³/h

m²W/W

Btu/h/w

90002600

100002900≤40≤50450

10~163.6412.6

110003200

120003500≤42≤50520

15~223.67

12.62

120003500

130003800≤42≤50550

17~243.75

12.86

180005200

195005700≤45≤55880

23~243.88

13.43

240007200

270007900≤50≤58

120030~503.85

12.83

IndoorOutdoor

Cooling Heating Cooling Heating

Max. power inputMax. current

Vacuum TubeSolar collector

diameter*length*pcs(L*W*T)

¢60mm*500mm*3/

Dimensions

/550*1000*90(mm)

WWWWWA

NetPackage

NetPackagePackage

Indoor UnitOutdoor Unit

Solar Collector

Net/GrossNet/GrossNet/Gross

kgkgkg

9/1136/39

11/1342/45

/

11/1344/47

16/1837/39

20/22/3

21/2343/47

mmmmmmmmmm

875*253*182945*343*272780*260*840853*333*880

/Weight

980*280*2201050*370*280825*310*545898*383*585

565*1015*130

7147363.613.728934.51

8728824.4

4.4510905.5

9339384.714.7411675.89

134013646.776.8916358.26

187019049.459.61226011.41

Air CirculationSuitable Area

EER

Rated PowerInput

Rated Current

Indoor Unit

Outdoor Unit

Solar collector

Power Consumption

Heating

Above parameters got under the rated working state : Effective sunshine : 800W/㎡

Cooling:outdoor unit dry bulb temperature 35℃/ wet bulb temperature 24℃, indoor unit dry bulb temperature 27℃/ wet bulb temperature 19℃

Heating:outdoor unit dry bulb temperature 7℃/ wet bulb temperature 6℃, indoor unit dry bulb temperature 20 ℃/ wet bulb temperature 15 ℃

Parameters may change due to ours company product improvement, please refer to product's nameplate .

www.suntchenergy.com

27 28

◆ Cassette Type

Model No. KFR-52DW-TYN KFR-72DW-TYN KFR-100DW-TYN KFR-120DW-TYN KFR-140DW-TYN

Power Supply 220-240V AC, 1PH, 50/60Hz

Performance

Power Consumption

Capacity

Noise Indoor

Outdoor

Air Circulation

Suitable Area

EER

Rated Power Input

Rated Current

Max. power input

Max. current

Solar collector

Indoor UnitNet

Package

Net

Package

Package

Indoor Unit

Outdoor Unit

Solar Collector

Net/Gross

Net/Gross

Net/Gross

kg

kg

kg

27/29.5

37/39

27/29.5

43/47

37/40

55/58

20/22

37/40

72/75

45/48

74/77

mm

mm

mm

mm

mm

950×950×350

1050×1050×410

825×310×545

898×383×585

950×950×390

1050×1050×460

930×310×830

973×383×880Outdoor Unit

Solar collector

(L*W*T) 550×1000×90(mm)

565×1015×130

Dimensions

Weight

Cooling

Heating

Cooling

Heating

W

W

W

W

W

A

1340

1364

6.77

6.89

1635

8.26

1870

1904

9.45

9.61

2282

11.52

2584

2686

13.05

13.56

3049

15.40

3038

3294

15.34

16.64

3585

18.11

3618

3837

18.27

19.38

4196

21.19

Btu/h

W

Btu/h

W

dB(A)

dB(A)

m³/h

W/W

Btu/h/w

18000

5200

19000

5700

≤46

≤56

850

23-34

3.88

13.43

24000

7200

27000

7900

≤51

≤58

1200

30-50

3.85

12.83

34000

10000

38000

11200

≤51

≤58

1700

42-67

3.87

13.16

41000

12000

47000

14000

≤53

≤60

1800

50-80

3.95

13.50

48000

14000

55000

16000

≤53

≤60

1900

58-93

3.87

13.27

Cooling

Heating

Above parameters got under the rated working state : Effective sunshine : 800W/㎡

Cooling : outdoor unit dry bulb temperature 35 ℃ / wet bulb temperature 24 ℃, indoor unit dry bulb temperature 27 ℃ / wet bulb temperature 19 ℃

Heating: outdoor unit dry bulb temperature 7 ℃ / wet bulb temperature 6 ℃, indoor unit dry bulb temperature 20 ℃ / wet bulb temperature 15 ℃

Parameters may change due to ours company product improvement, please refer to product's nameplate .

Model No. KFR-52LW-TYN KFR-72LW-TYN KFR-100LW-TYN KFR-120LW-TYN KFR-140LW-TYN

Power Supply 220-240V AC, 1PH, 50/60Hz

Performance

Power Consumption

Capacity

Noise Indoor

Outdoor

Air Circulation

Suitable Area

EER

Rated Power Input

Rated Current

Max. power input

Max. current

Solar collector

Indoor UnitNet

Package

Net

Package

Package

Indoor Unit

Outdoor Unit

Solar Collector

Net/Gross

Net/Gross

Net/Gross

kg

kg

kg

35/37

37/39

43/47

43/47

44/47

55/58

20/22

51/53

72/75

53/57

74/77

mm

mm

mm

mm

mm

1675×491×248

1775×621×308

825×310×545

898×383×585

1750×500×268

1850×630×320

930×310×830

973×383×880Outdoor Unit

Solar collector

(L*W*T) 550×1000×90(mm)

565×1015×130

Dimensions

Weight

Cooling

Heating

Cooling

Heating

W

W

W

W

W

A

1340

1364

6.77

6.89

1635

8.26

1870

1904

9.45

9.61

2282

11.52

2584

2686

13.05

13.56

3049

15.40

3038

3294

15.34

16.64

3585

18.11

3618

3837

18.27

19.38

4196

21.19

Btu/h

W

Btu/h

W

dB(A)

dB(A)

m³/h

W/W

Btu/h/w

18000

5200

19000

5700

≤46

≤56

850

23-34

3.88

13.43

24000

7200

27000

7900

≤51

≤58

1200

30-50

3.85

12.83

34000

10000

38000

11200

≤51

≤58

1700

42-67

3.87

13.16

41000

12000

47000

14000

≤53

≤60

1800

50-80

3.95

13.50

48000

14000

55000

16000

≤53

≤60

1900

58-93

3.87

13.27

Cooling

Heating

Above parameters got under the rated working state : Effective sunshine : 800W/㎡

Cooling : outdoor unit dry bulb temperature 35 ℃ / wet bulb temperature 24 ℃, indoor unit dry bulb temperature 27 ℃ / wet bulb temperature 19 ℃

Heating: outdoor unit dry bulb temperature 7 ℃ / wet bulb temperature 6 ℃, indoor unit dry bulb temperature 20 ℃ / wet bulb temperature 15 ℃

Parameters may change due to ours company product improvement, please refer to product's nameplate .

www.suntchenergy.com

29 30

◆ Floor Standing Type