hc catalog. evaporators and condensers
TRANSCRIPT
-
8/18/2019 HC Catalog. Evaporators and Condensers
1/157
-
8/18/2019 HC Catalog. Evaporators and Condensers
2/157
HC HEAT - EXCHANGERS
CATALOGUE INDEX
Index
page 1 of 201-10-2009
PAGE PRODUCT DESCRIPTION
4 WELCOME TO HC
6 COILS CUSTOMER COILS
8 HCV-500-A AIR COOLED CONDENSER
12 HCV-630-A AIR COOLED CONDENSER
16 HCV-800-A AIR COOLED CONDENSER
21 HVV-500-A V SHAPED AIR COOLED CONDENSER
25 HVV-630-B V SHAPED AIR COOLED CONDENSER
28 HVV-800-B V SHAPED AIR COOLED CONDENSER
32 HAV-350-A REMOTE AIR COOLED CONDENSER
35 HAV-400-A REMOTE AIR COOLED CONDENSER
38 HAV-500-A REMOTE AIR COOLED CONDENSER
41 HCB-200-A AIR COOLED CONDENSER + BASE
44 HCB-250-B AIR COOLED CONDENSER + BASE
47 HCBC-300-A AIR COOLED CONDENSER + BASE
50 HCB-300-A AIR COOLED CONDENSER + BASE
53 HCB-350-A AIR COOLED CONDENSER + BASE
56 HCB-400-A AIR COOLED CONDENSER + BASE
59 HCB-500-B AIR COOLED CONDENSER + BASE
62 HCB-630-D AIR COOLED CONDENSER + BASE
65 HLR LIQUID RECEIVER
-
8/18/2019 HC Catalog. Evaporators and Condensers
3/157
CATALOGUE INDEX Indexpage 2 of 2
01-10-2009
PAGE PRODUCT DESCRIPTION
68RONDO - B UNIT COOLER
72 HWM-300 - A WALL MOUNTED COOLER
75 HDD 200 DUAL DISCHARGE UNIT COOLER
78 HDD 250 DUAL DISCHARGE UNIT COOLER
82 HDD 300 DUAL DISCHARGE UNIT COOLER
87 HDD 350 DUAL DISCHARGE UNIT COOLER
93 HDD 500 DUAL DISCHARGE UNIT COOLER
101 HCT-250 LOW SILHOUETTE UNIT COOLER
104 HCR 300 LOW SILHOUETTE UNIT COOLER
Note:
subject
to
change
without
notice
104 HCR-300 LOW SILHOUETTE UNIT COOLER
107 HDR-300 UNIT COOLER
110 HSR-300 UNIT COOLER
114 HSR-350 UNIT COOLER
117 HSR-50 UNIT COOLER
121 HRR-50
126 HPR-500 UNIT COOLER
131 HMR-630 UNIT COOLER
136 HDC-500 DRY-COOLER
139 HDC-63 DRY-COOLER
142 Appendix A UNIT COOLER CORRECTION FACTORS
146 Appendix B EC FAN WIRING- 500mm Fan
149 Appendix C EC FAN WIRING- 800mm Fan
153 Appendix D Catalogue Summery
Note:
subject
to
change
without
notice
-
8/18/2019 HC Catalog. Evaporators and Condensers
4/157
WELCOME TO HC HEAT-EXCHANGERS (Pty) Ltd
The Heating Centre group was founded in 1973 and rapidly built a reputation for superb
engineering and manufacture of airconditioning and refrigeration systems and components.
Quality and service was a key contribution to this success.
For a period from 1995 to 2001 the company was owned by a German concern, which traded asGüntner SA. After the Germans withdrew from South Africa the Company was re-purchased
and opened as HC Heat-Exchangers concentrating on customized coils, refrigeration unit
.
HC Heat-Exchangers has drawn from its rich engineering background to supply you, the
customer, with an unsurpassed product in terms of engineering, quality and service.
HC Heat-Exchangers credits its success to the committed people who make up this family.
The HC family is proud to introduce this catalogue and looks forward to a mutually beneficial
.
On behalf of HC Heat-Exchangers
Robert Kruger
Managing Director
Page 4
-
8/18/2019 HC Catalog. Evaporators and Condensers
5/157
Page 5
-
8/18/2019 HC Catalog. Evaporators and Condensers
6/157
HC HEAT - EXCHANGERS
CUSTOMER COILS
COILS
Page 1 of 2
01-10-2009
General Description
HC Heat-Exchangers manufacture a wide range of plate fin type coils for air conditioning,refrigeration and
industrial applications suitable for chilled water, hot water, steam, evaporator and condenser systems.Tubes are mechanicaly expanded into plate fins and after brazing all coils are leak tested to 3200 kPausing dry Nitrogen under water.Tube options are 9.53mm, 12 mm and 15.88 mm OD copper tube (planeor rifle bore) or 12 mm OD 304L stainless steel tubes. Fin options are aluminium, copper and coatedaluminium while casings are available in galvanised iron, aluminium stainless steel or copper.
Only the finest materials are used to give a top quality product with a long, trouble free service life.
Coil selections are computer generated to accomodate the many variables encountered.
Note:
subject
to
change
without
notice
3A 3B 3C 4A 4B 5A 5B
3A 3B 3C 4A 4B 5A 5B
*CW-3A *CW-3B *CW-3C **CW-4A *CW-4B *CW-5A *CW-5B
*HW-3A *HW-3B *HW-3C **HW-4A *HW-4B *HW-5A *HW-5B*ST-3A *ST-3B *ST-3C **ST-4A *ST-4B *ST-5A *ST-5B
*AC-3A *AC-3B *AC-3C **AC-4A *AC-4B *AC-5A *AC-5B
*DX-3A *DX-3B *DX-3C **DX-4A *DX-4B *DX-5A *DX-5B
- - - SFA-4A SFA-4B - -
* = plain copper, r ifle bore copper ** Plain copper, r ifle bore copper , 304 stainless steel
Tube Material Fin Material Casing MaterialP = Plain Copper Al = Aluminium Gi = Galvanised iron
R = Rifle bore copper Cu = Plain copper Al = stainless steel
S = 304 Stainless steel Ep = coated aluminium Cu = plain copper
Tube size 12mm
Evaporator [DX]
Flooded ammonia[FA
15.88mm9.53mm
Fin Pattern
Chilled water [CW]
Hot Water [HW]Steam [ST]
Condenser [AC]
Coil Type:
X XX - XX - XX x XXXX x X R x XX F x XX C
Tube Material
Coil Type
Fin pattern
No tubes high Finned length [mm]
Rows deep
Fins per inch
No of circuits
NOMENCLATURE
Note:
subject
to
change
without
notice
Page 6
-
8/18/2019 HC Catalog. Evaporators and Condensers
7/157
HC HEAT - EXCHANGERS
CUSTOMER COILS
COILS
Page 2 of 2
01-10-2009
DATA CW HW ST AC DX FA
Capacity kW X X X X X X
Air Flow m3/s X X X X X X
Air Inlet temp °C (DB & WB) X X X X X X
Air Outlet temp °C (DB & WB) X X X X X
Water Flow l/s X X
Water Inlet Temp °C X X
Water Outlet temp °C X X
Condensing Temp °C X
Evaporating temp °C X X
Refrigerant X X X
Steam Pressure kPa XSteam Temp °C X
Altitude m X X X X X X
Size H x L mm x mm X X X X X X
Data Required for Coil Selections
Typical Example
---------- CONDENSER CALCULATOR REPORT --------03/12/2009
RAC-3A - 23 x 2250 x 4R x 12.00F x 11.43C - Ri/Al
COIL DESIGNTubing 10.1 x 0.3 mmHeight 23.6 in.Length 2250 mm.Tube rows 4Fin spacing 12 fpiCircuits 11.43
BAROMETER Atmospheric pressure 101.36 kPa Altitude 0.00 m
AIREntering temperature 30/20.04 CLeaving temperature 41.22/23.27 CRH ON 40 %RH OFF 21.50 %Mass flow 5.814 kg/sVolume flow 5.023 m3/sFace velocity 3.725 m/s
Typical Print-out
Note:
subject
to
change
without
notice
Notes:For fluids other than water, ethylene glycolor propylene glycol the following wouldalso be required:
Density kg/m3
Heat capacity kJ/kgKConductivity kW.mKx1e6Viscosity mg/ms
Condensing THR: 66kW Air flow 5 m3/s Air on coil 30.0 /20.0 °CCondensing Temp 45 °CRefrigerant R22
Altitude: Sea levelSize (H x L) 600 x 3360 mm
Pressure drop 143.03 PaFan 3.00 x
EBM S4D 500REFRIGERANT (R22)Condensing temperature 45.00 CDesuperheating 0.00 KSubcooling 3.00 KMass flow 0.406 kg/sCharge 4.66 kg
Pressure drop 40.54 kPaDUTYTotal duty 66.849 kW
150150
50
40
40
F I N
150
150
MOUNTING HOLES Ø1 0.15 AT 150 CRS
AIR VENT
DRAIN
BENDSMAX OVER
LONGERIF 1500 mm O RCENTRE PLATE
FINNED
40 40
LEFT HAND
CONNECTION
CHILLED WATER IN
BSPM
AIR FLOW
BSPM
CHILLED WATER OUT
CHILLED WATER IN
BSPM
RIGHT HANDCONNECTION
Note:
subject
to
change
without
notice
Page 7
-
8/18/2019 HC Catalog. Evaporators and Condensers
8/157
HC HEAT - EXCHANGERS
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 500mm FANS
HCV - 500 - B
Page 1 of 431-10-2011
General Description
The HCV-501-B to -508-B range of Air Cooled Condensers comprises 32models covering duties from21.9kW to 233.4kW total heat rejection at 15K ITD. The range of low profile appearance units is ideal forroof-mounted applications. The low noise level modular fan arrangement is well suited to economical fancycling head pressure control. Each unit is factory wired to a terminal strip in a terminal box. The coilincorporates our floating coil construction, eliminating tube failure at the tube plates, with resultant refrigerantloss and thus ensures a long trouble-free service life.
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing•• EC modulating fans
General Description
The HCV-501-B to -508-B range of Air Cooled Condensers comprises 32models covering duties from21.9kW to 233.4kW total heat rejection at 15K ITD. The range of low profile appearance units is ideal forroof-mounted applications. The low noise level modular fan arrangement is well suited to economical fancycling head pressure control. Each unit is factory wired to a terminal strip in a terminal box. The coilincorporates our floating coil construction, eliminating tube failure at the tube plates, with resultant refrigerantloss and thus ensures a long trouble-free service life.
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• RAL-7032 Kiesel grey colour
• Baffled individual fan sections
• Vertical air discharge
• Single system operation
• 400/3/50 Hz fan motor
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing•• EC modulating fans
• Fan cycling head pressure control
• Horizontal air discharge
• Multiple system operation
• 230/1/50 Hz fan motor
No. of systems
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H C V – 501 – B 4R - 2S
Nomenclature
HC Heat-Exchangers
Air cooled condenser
V = Vertical air flowH = Horizontal air flow
Fan diameter -cm
-
8/18/2019 HC Catalog. Evaporators and Condensers
9/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 500mm FANS
HCV - 500 - B
Page 2 of 431-10-2011
501-2R 501-3R 501-4R 502-2R 502-3R 502-4R 503-2R 503-3R 503-4R 504-2R 504-3R 504-4R
1.5 1.8 2.0 2.9 3.5 3.9 4.3 5.3 5.8 5.7 7.1 7.8
14.6 18.0 19.8 28.9 35.5 39.0 43.3 53.2 58.4 57.4 70.9 77.8
16.0 19.8 21.8 31.8 39.0 42.8 47.6 58.5 64.2 63.1 78.0 85.6
17.5 21.6 23.8 34.6 42.6 46.7 52.0 63.8 70.0 68.9 85.1 93.4
19.0 23.4 25.8 37.5 46.1 50.6 56.3 69.2 75.9 74.6 92.2 101.1
20.4 25.2 27.7 40.4 49.6 54.5 60.6 74.5 81.7 80.3 99.3 108.9
21.9 27.0 29.7 43.3 53.2 58.4 64.9 79.8 87.5 86.1 106.4 116.7
23.3 28.8 31.7 46.2 56.7 62.3 69.3 85.1 93.4 91.8 113.5 124.5
24.8 30.6 33.7 49.1 60.3 66.2 73.6 90.4 99.2 97.6 120.6 132.326.2 32.4 35.7 52.0 63.8 70.1 77.9 95.7 105.0 103.3 127.7 140.0
27.7 34.2 37.6 54.8 67.4 74.0 82.3 101.1 110.9 109.0 134.8 147.8
29.2 36.0 39.6 57.7 70.9 77.9 86.6 106.4 116.7 114.8 141.9 155.6
No. of fans
Air quantity m3 /s 2.42 2.26 2.12 4.81 4.48 4.19 7.21 6.72 6.28 9.64 8.97 8.38
1 System Intlet OD inch 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8" 2 1/8"
1 System Outlet OD inch 5/8" 5/8" 5/8" 7/8" 7/8" 7/8" 7/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8"
2 System Inlet OD inch 7/8" 7/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8"
2 System Outlet OD inch 1/2" 1/2" 1/2" 5/8" 5/8" 5/8" 5/8" 7/8" 7/8" 7/8" 7/8" 7/8"
Coil face area m2
Inter. Coil vol. litres 4.06 6.09 8.12 9.84 14.76 19.68 11.53 17.29 23.05 15.56 22.82 30.43R22 1.17 1.71 2.25 2.22 3.29 4.34 3.34 4.94 6.56 4.66 6.58 8.74
R404A 1.3 1.90 2.5 2.47 3.66 4.83 3.72 5.5 7.31 5.34 7.34 9.75
R134a 1.11 1.61 2.12 2.09 3.09 4.08 3.14 4.64 6.17 4.2 6.19 8.22
R22 3.6 5.4 7.2 8.7 13.1 17.5 10.2 15.4 20.5 13.8 20.3 27.0
R404A 3.1 4.6 6.1 7.4 11.1 14.9 8.7 13.0 17.4 11.8 17.2 23.0
R134a 3.7 5.5 7.3 8.9 13.3 17.8 10.4 15.6 20.8 14.1 20.6 27.5
Technical & Physical Data
0.70 1.35 2.02
1 2 3
14
20
2.70
Pump - down capacity
kg @ 80%
1
ITD K
10
11
12
13
4
Model
Total Heat Rejection - kW
15
16
17
18
19
Refrigerant operating
charge kg
n
Cu fin 102 112 122 158 178 197 214 242 270 269 306 343
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Net mass kg
Altitude correction factors
Capacity Correction
Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
Example:
Required THR: 120 kWAmbient design condition: 36°CAltitude: 1800mCondensing temperature: 50 °CRefrigerant: R404A
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 50°C - 36°C = 14°C
Correction Factor R404A = 1.03Correction Factor 1800m = 0.88
Required capacity at catalogue conditions:
120 kW ÷ 1.03 ÷ 0.88 = 132.4kW THR required at14°C ITD, Refrigerant R22, Altitude 0m
At 14°C ITD the "HCV-505-4R" gives 136.4 kW
Select the "HCV-505-4R"
-
8/18/2019 HC Catalog. Evaporators and Condensers
10/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 500mm FANS
HCV - 500 - B
Page 3 of 431-10-2011
505-2R 505-3R 505-4R 506-2R 506-3R 506-4R 507-2R 507-3R 507-4R 508-2R 508-3R 508-4R
7.2 8.9 9.7 8.6 10.7 11.7 10.0 12.4 13.6 11.5 14.1 15.6
71.7 88.7 97.4 86.1 106.6 116.7 100.4 124.1 136.1 114.8 140.8 155.6
78.9 97.5 107.1 94.7 117.3 128.4 110.5 136.5 149.7 126.3 154.9 171.2
86.1 106.4 116.9 103.3 127.9 140.1 120.5 149.0 163.4 137.7 168.9 186.7
93.3 115.3 126.6 111.9 138.6 151.8 130.6 161.4 177.0 149.2 183.0 202.3
100.4 124.1 136.4 120.5 149.2 163.4 140.6 173.8 190.6 160.7 197.1 217.8
107.6 133.0 146.1 129.1 159.9 175.1 150.7 186.2 204.2 172.2 211.2 233.4
114.8 141.9 155.8 137.7 170.6 186.8 160.7 198.6 217.8 183.6 225.3 249.0
122.0 150.7 165.6 146.3 181.2 198.4 170.7 211.0 231.4 195.1 239.3 264.5129.1 159.6 175.3 155.0 191.9 210.1 180.8 223.4 245.0 206.6 253.4 280.1
136.3 168.5 185.1 163.6 202.5 221.8 190.8 235.9 258.7 218.1 267.5 295.6
143.5 177.3 194.8 172.2 213.2 233.5 200.9 248.3 272.3 229.6 281.6 311.2
No. of fans
Air quantity m3 /s 12.05 11.21 10.47 14.46 13.45 12.57 16.87 15.69 14.66 19.28 17.98 16.76
1 System Intlet OD inch 1 5/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8"
1 System Outlet OD inch 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 1/8" 1 1/8" 1 3/8" 1 1/8" 1 3/8" 1 3/8"
2 System Inlet OD inch 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8" 2 1/8"
2 System Outlet OD inch 7/8" 7/8" 7/8" 7/8" 7/8" 1 1/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8"
Coil face area m2
Inter. Coil vol. litres 19.33 28.35 37.80 23.09 33.88 45.17 26.86 39.41 52.54 30.62 45.93 59.91R22 5.82 8.23 10.85 6.99 9.88 13.12 8.15 11.52 15.3 9.31 13.86 17.49
R404A 6.67 9.18 12.09 8 11.01 14.63 9.34 12.84 17.06 10.6 15.70 19.7
R134a 5.52 7.74 10.12 6.72 9.29 12.34 7.84 10.83 14.38 8.84 13.1 16.45
R22 17.2 25.2 33.6 50.5 30.1 40.1 23.9 35.0 46.7 27.2 40.8 53.2
R404A 14.6 21.4 28.5 20.9 25.6 34.1 20.3 29.7 39.7 23.1 34.7 45.2
R134a 17.5 25.6 34.1 17.4 30.6 40.8 24.3 35.6 47.5 27.7 41.5 54.1
Technical & Physical Data
ITD K
1
10
17
18
11
12
13
14
15
16
Refrigerant operating
charge kg
Pump - down capacity
kg @ 80%
19
20
Model
Total Heat Rejection - kW
5 6
3.37 4.05
87
4.72 5.39
n
Cu fin 340 386 432 391 446 501 458 523 588 513 587 661
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Net mass kg
Altitude correction factors
Example:
Required THR: 120 kWAmbient design condition: 36°CAltitude: 1800mCondensing temperature: 50 °CRefrigerant: R404A
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 50°C - 36°C = 14°C
Correction Factor R404A = 1.03Correction Factor 1800m = 0.88
Required capacity at catalogue conditions:
120 kW ÷ 1.03 ÷ 0.88 = 132.4kW THR required at14°C ITD, Refrigerant R22, Altitude 0m
At 14°C ITD the "HCV-505-4R" gives 136.4 kW
Select the "HCV-505-4R"
Capacity Correction
Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
11/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 500mm FANS
HCV - 500 - B
Page 4 of 431-10-2011
Note:- Center leg on models 505 & larger- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410A _ applications
Fan:
AC 500mm diameter400/ 3/50 Hz.0.72 kW 1.41 A Each.
Coil:
- 3/8" Rifle bore copper tube- Aluminium fin- 12 fins per inch
Fan Wiring
Motor Diameter Voltage Frequency Speed Power Amperagemm V Hz rpm W A
3 Phase DELTA 500 400 50 1390 720 1.41 StandardEC 500 400 50 1440 1050 1.90 Optional1 Phase 500 230 50 1300 680 3.00 Optional
NATAL
P.O Box 30620
Mayville, 4058Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENG
P.O Box 147
Maraisburg, 1700Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIA
P.O Box 1301
WindhoekTel: (0926461) 261-647Fax: (0926461) 216-201
CAPE
P.O Box 36640
Chempet, 7442Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
L1 - BLACKL2 - BLUEL3 - BROWNTOP - PURPLETOP - PINKE - GREEN / YELLOWF1 - FAN MOTOR
L1 L2 L3 TOP
F1
ETOP
Note:- Center leg on models 505 & larger- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410A _ applications
Fan:
AC 500mm diameter400/ 3/50 Hz.0.72 kW 1.41 A Each.
Coil:
- 3/8" Rifle bore copper tube- Aluminium fin- 12 fins per inch
NOTE: SEE APPEDIX B FOR EC FAN WIRING
-
8/18/2019 HC Catalog. Evaporators and Condensers
12/157
HC HEAT - EXCHANGERS
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 630mm FANS
HCV - 630 - B
Page 1 of 415-07-2011
General Description
The HCV-631-B to -636-B range of Air Cooled Condensers comprises 18 models covering duties from48.4kW to 420.9 kW total heat rejection at 15K ITD. The range of low profile appearance units is ideal forroof-mounted applications. The low noise level modular fan arrangement is well suited to economical fancycling head pressure control. Each unit is factory wired to a terminal strip in a terminal box. The coilincorporates our floating coil construction, eliminating tube failure at the tube plates, with resultant refrigerantloss and thus ensures a long trouble-free service life.
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• -
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing
• Fan cycling head pressure control
General Description
The HCV-631-B to -636-B range of Air Cooled Condensers comprises 18 models covering duties from48.4kW to 420.9 kW total heat rejection at 15K ITD. The range of low profile appearance units is ideal forroof-mounted applications. The low noise level modular fan arrangement is well suited to economical fancycling head pressure control. Each unit is factory wired to a terminal strip in a terminal box. The coilincorporates our floating coil construction, eliminating tube failure at the tube plates, with resultant refrigerantloss and thus ensures a long trouble-free service life.
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• RAL-7032 Kiesel grey colour
• Baffled individual fan sections
• Vertical air discharge
• Single system operation
• 400/3/50 Hz fan motor
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing
• Fan cycling head pressure control
• Horizontal air discharge
• Multiple system operation
H C V – 631 – B 4R - 2S
Nomenclature
HC Heat-Exchangers
Air cooled condenser
V = Vertical air flowH = Horizontal air flow
Fan diameter -cm
No. of systems
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
-
8/18/2019 HC Catalog. Evaporators and Condensers
13/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 630mm FANS
HCV - 630 - B
Page 2 of 415-07-2011
631-2R 631-3R 631-4R 632-2R 632-3R 632-4R 633-2R 633-3R 633-4R
3.2 4.1 4.7 6.5 8.2 9.4 9.7 12.4 14.0
32.3 41.0 46.5 64.8 82.4 93.5 97.2 123.6 140.3
35.5 45.2 51.2 71.3 90.6 102.9 106.9 136.0 154.3
38.7 49.3 55.9 77.8 98.9 112.2 116.6 148.3 168.3
41.9 53.4 60.5 84.2 107.1 121.6 126.4 160.7 182.3
45.2 57.5 65.2 90.7 115.4 130.9 136.1 173.0 196.4
48.4 61.6 69.8 97.2 123.6 140.3 145.8 185.4 210.4
51.6 65.7 74.5 103.7 131.8 149.7 155.5 197.8 224.4
54.9 69.8 79.1 110.1 140.1 159.0 165.2 210.1 238.558.1 73.9 83.8 116.6 148.3 168.4 175.0 222.5 252.5
61.3 78.0 88.4 123.1 156.6 177.7 184.7 234.8 266.5
64.5 82.1 93.1 129.6 164.8 187.1 194.4 247.2 280.5
No. of fans
Air quantity m3 /s 5.33 5.19 5.04 10.67 10.39 10.11 16.00 15.58 15.17
1 System Intlet OD inch 1 3/8" 1 3/8" 1 3/8" 1 5/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 5/8"
1 System Outlet OD inch 7/8" 7/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8"
2 System Inlet OD inch 1 3/8" 1 3/8" 1 3/8"
2 System Outlet OD inch 5/8" 7/8" 7/8"
Coil face area m2
Inter. Coil vol. litres 9.39 14.09 18.78 18.69 28.04 37.38 27.59 41.39 55.18R22 2.65 3.89 5.15 5.34 7.84 10.36 8.01 11.76 15.55
R404A 2.96 4.34 5.74 5.95 8.74 11.55 8.93 13.11 17.34
R134a 2.54 3.70 4.89 5.07 7.45 9.84 7.61 11.17 14.77
R22 8.3 12.5 16.7 16.6 24.9 33.2 24.5 36.8 49.0
R404A 7.1 10.6 14.2 14.3 21.4 28.5 20.8 31.2 41.7
R134a 8.5 12.7 17.0 16.9 25.3 33.8 24.9 37.4 49.8
15
16
17
18
19
20
Refrigerant operating
charge kg
Pump - down capacity
kg @ 80%
14
ITD K
10
11
12
13
Technical & Physical Data
Model
Total Heat Rejection - kW
1.51 3.05 4.57
1 2 3
1
n
Cu fin 202 233 264 345 407 469 498 590 682
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88Altitude correction factors
Net mass kg
Example:
Required THR: 115 kWAmbient design condition: 32°CAltitude: 1600mCondensing temperature: 45 °CRefrigerant: R507
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 45°C - 32°C = 13°C
Correction Factor R507 = 1.03Correction Factor 1600m = 0.9
Required capacity at catalogue conditions:
115 kW ÷ 1.03 ÷ 0.9 = 124 kW THR required at13°C ITD, Refrigerant R22, Altitude 0m
At 13°C ITD the "HCV-633-2R" gives 126.4 kW
Select the "HCV-633-2R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
14/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 630mm FANS
HCV - 630 - B
Page 3 of 415-07-2011
634-2R 634-3R 634-4R 635-2R 635-3R 635-4R 636-2R 636-3R 636-4R
13.0 16.5 18.7 16.2 20.6 23.4 19.4 24.7 28.1
129.6 164.8 187.1 162.0 206.1 233.8 194.4 247.3 280.6
142.6 181.3 205.8 178.2 226.7 257.2 213.8 272.0 308.7
155.5 197.8 224.5 194.4 247.3 280.6 233.3 296.7 336.7
168.5 214.2 243.2 210.6 267.9 303.9 252.7 321.4 364.8
181.4 230.7 261.9 226.8 288.5 327.3 272.2 346.2 392.8
194.4 247.2 280.6 243.0 309.1 350.7 291.6 370.9 420.9
207.4 263.7 299.3 259.2 329.7 374.1 311.0 395.6 449.0
220.3 280.2 318.0 275.4 350.3 397.5 330.5 420.4 477.0233.3 296.6 336.7 291.6 370.9 420.8 349.9 445.1 505.1
246.2 313.1 355.4 307.8 391.5 444.2 369.4 469.8 533.1
259.2 329.6 374.1 324.0 412.1 467.6 388.8 494.5 561.2
No. of fans
Air quantity m3 /s 21.34 20.78 20.22 26.68 25.98 25.28 32.02 31.18 30.34
1 System Intlet OD inch 2 1/8" 2 5/8" 2 5/8" 2 5/8" 2 5/8" 2 5/8" 2 5/8" 2 5/8" 2 5/8"
1 System Outlet OD inch 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 5/8" 1 5/8" 1 3/8" 1 5/8" 1 5/8"
2 System Inlet OD inch 1 5/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8"
2 System Outlet OD inch 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8"
Coil face area m2
Inter. Coil vol. lit res 36.49 54.74 72.98 45.39 68.09 90.78 54.30 81.45 108.60R22 10.68 15.68 20.73 13.35 19.60 25.92 16.01 23.52 31.10
R404A 11.91 17.48 23.11 14.89 21.85 28.90 17.85 26.22 34.92
R134a 10.15 14.90 19.69 12.68 18.62 24.62 15.21 22.34 29.44
R22 32.4 48.6 64.8 40.3 60.5 80.6 48.2 72.3 96.4
R404A 27.6 41.3 55.1 34.3 51.4 68.5 41.0 61.5 82.0
R134a 33.0 49.4 65.9 41.0 61.5 82.0 49.0 73.6 98.1
Total Heat Rejection - kW
Model
19
20
11
12
4 5
Technical & Physical Data
ITD K
1
10
Refrigerant operating
charge kg
Pump - down capacity
kg @ 80%
6
6.10 7.62 9.14
17
18
13
14
15
16
n
Cu fin 639 762 885 796 949 1102 936 1120 1304
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Net mass kg
Altitude correction factors
Example:
Required THR: 115 kWAmbient design condition: 32°CAltitude: 1600mCondensing temperature: 45 °CRefrigerant: R507
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 45°C - 32°C = 13°C
Correction Factor R507 = 1.03Correction Factor 1600m = 0.9
Required capacity at catalogue conditions:
115 kW ÷ 1.03 ÷ 0.9 = 124 kW THR required at13°C ITD, Refrigerant R22, Altitude 0m
At 13°C ITD the "HCV-633-2R" gives 126.4 kW
Select the "HCV-633-2R"
Capacity Correction
Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
15/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 630mm FANS
HCV - 630 - B
Page 4 of 415-07-2011
Note:- Centre leg on models 633 & larger- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410A _ applications
Fan:- AC 630mm diameter- 400/3/50 Hz.- 2.63 kW 4.78 A Each.
Coil:- 12mm Rifle bore copper tube- Aluminium fin- 12 fins per inch
Fan WiringMotor Diameter Voltage Frequency Speed Power Amperage
mm V Hz rpm W A
3 Phase DELTA
Standard3 Phase STAR OptionalEC Optional
NATALP.O Box 30620Mayville, 4058Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENGP.O Box 147Maraisburg, 1700Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIAP.O Box 1301WindhoekTel: (0926461) 261-647Fax: (0926461) 216-201
CAPEP.O Box 36640Chempet, 7442Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
L1 - BLACKL2 - BLUEL3 - BROWNTOP - PURPLETOP - PINKE - GREEN / YELLOWF1 - FAN MOTOR
L1 L2 L3 TOP
F1
ETOP
Note:- Centre leg on models 633 & larger- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410A _ applications
Fan:- AC 630mm diameter- 400/3/50 Hz.- 2.63 kW 4.78 A Each.
Coil:- 12mm Rifle bore copper tube- Aluminium fin- 12 fins per inch
-
8/18/2019 HC Catalog. Evaporators and Condensers
16/157
HC HEAT - EXCHANGERS
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 800mm FANS
HCV - 800 - B
Page 1 of 415-07-2011
General Description
The HCV-801-B to -806-B range of Air Cooled Condensers comprises 18 models covering duties from 62.1kW to 513.3 kW total heat rejection at 15K ITD. The range of low profi le appearance units is ideal for roof-mounted applications. The low noise level modular fan arrangement is well suited to economical fan cyclinghead pressure control. Each unit is factory wired to a terminal strip in a terminal box. The coil incorporatesour floating coil construction, eliminating tube failure at the tube plates, with resultant refrigerant loss andthus ensures a long trouble-free service life.
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• RAL-7032 Kiesel grey colour
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing
• Horizontal air discharge
General Description
The HCV-801-B to -806-B range of Air Cooled Condensers comprises 18 models covering duties from 62.1kW to 513.3 kW total heat rejection at 15K ITD. The range of low profi le appearance units is ideal for roof-mounted applications. The low noise level modular fan arrangement is well suited to economical fan cyclinghead pressure control. Each unit is factory wired to a terminal strip in a terminal box. The coil incorporatesour floating coil construction, eliminating tube failure at the tube plates, with resultant refrigerant loss andthus ensures a long trouble-free service life.
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• RAL-7032 Kiesel grey colour
• Baffled individual fan sections
• Vertical air discharge
• Single system operation
• EC 800mm Modulating fans
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing
• Horizontal air discharge
• Multiple system operation
• 400/3/50 Hz AC Fan motor
Nomenclature
HC Heat-Exchangers
Air cooled condenser
V = Vertical air flowH = Horizontal air flow
Fan diameter -cm
No. of systems
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H C V – 801 – B 4R - 2S
-
8/18/2019 HC Catalog. Evaporators and Condensers
17/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 800mm FANS
HCV - 800 - B
Page 2 of 415-07-2011
801-2R 801-3R 801-4R 802-2R 802-3R 802-4R 803-2R 803-3R 803-4R
4.1 5.2 5.8 8.1 10.2 11.4 12.2 15.3 17.1
41.4 51.7 57.8 81.3 101.5 114.1 122.0 152.7 171.1
45.5 56.9 63.6 89.5 111.7 125.5 134.2 168.0 188.2
49.7 62.0 69.4 97.6 121.8 136.9 146.4 183.3 205.3
53.8 67.2 75.2 105.7 132.0 148.3 158.6 198.6 222.4
58.0 72.4 81.0 113.9 142.1 159.7 170.8 213.8 239.5
62.1 77.5 86.8 122.0 152.3 171.1 183.0 229.1 256.6
66.2 82.7 92.6 130.1 162.5 182.5 195.2 244.4 273.7
70.4 87.9 98.3 138.3 172.6 193.9 207.4 259.6 290.874.5 93.0 104.1 146.4 182.8 205.3 219.6 274.9 307.9
78.6 98.2 109.9 154.5 192.9 216.7 231.8 290.2 325.0
82.8 103.4 115.7 162.7 203.1 228.1 244.0 305.5 342.1
No. of fans
Air quantity m3 /s 6.47 6.24 6.02 12.86 12.40 11.96 19.29 18.59 17.94
1 System Intlet OD inch 1 3/8" 1 5/8" 1 5/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 5/8" 2 5/8"
1 System Outlet OD inch 7/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8"
2 System Inlet OD inch 1 3/8" 1 5/8" 1 5/8"
2 System Outlet OD inch 7/8" 7/8" 7/8"
Coil face area m2
Inter. Coil vol. lit res 11.83 17.74 23.65 22.54 33.80 45.07 33.33 50.00 66.66R22 3.63 5.38 7.07 6.94 10.41 13.56 10.41 15.41 20.34
R404A 4.05 6.00 7.88 7.74 11.61 11.63 11.61 17.18 17.47
R134a 3.45 5.11 6.72 6.59 9.89 13.79 9.89 14.64 20.69
R22 10.5 15.8 21.0 20.0 30.0 40.0 29.6 44.4 59.2
R404A 9.0 13.5 18.0 17.2 25.8 34.3 25.4 38.1 50.8
R134a 10.7 16.0 21.4 20.4 30.5 40.7 30.1 45.2 60.2
Technical & Physical Data
Model
Total Heat Rejection - kW
1.51 3.05 4.57
1 2 3
1
14
ITD K
10
11
12
13
15
16
17
18
19
20
Refrigerant operating
charge kg
Pump - down capacity
kg @ 80%
n
Cu fin 260 302 344 456 537 618 659 781 903
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88Altitude correction factors
Net mass kg
Example:
Required THR: 320 kWAmbient design condition: 35°CAltitude: 1800mCondensing temperature: 50 °CRefrigerant: R22
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 50°C - 35°C = 15°C
Correction Factor R22 = 1Correction Factor 1800m = 0.88
Required capacity at catalogue conditions:
320 kW ÷ 1 ÷ 0.88 = 363 kW THR required at15°C ITD, Refrigerant R22, Altitude 0m
At 15°C ITD the "HCV-806-2R" gives 366.0 kWSelect the "HCV-806-2R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
18/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 800mm FANS
HCV - 800 - B
Page 3 of 415-07-2011
804-2R 804-3R 804-4R 805-2R 805-3R 805-4R 806-2R 806-3R 806-4R
16.3 20.3 22.8 20.3 25.4 28.5 24.4 30.5 34.2
162.7 203.1 228.1 203.3 253.9 285.1 244.0 305.5 342.2
178.9 223.4 250.9 223.7 279.3 313.6 268.4 336.0 376.4
195.2 243.7 273.8 244.0 304.6 342.2 292.8 366.6 410.6
211.5 264.0 296.6 264.3 330.0 370.7 317.2 397.1 444.9
227.7 284.3 319.4 284.7 355.4 399.2 341.6 427.7 479.1
244.0 304.6 342.2 305.0 380.8 427.7 366.0 458.2 513.3
260.3 324.9 365.0 325.3 406.2 456.2 390.4 488.7 547.5
276.5 345.2 387.8 345.7 431.6 484.7 414.8 519.3 581.7292.8 365.5 410.6 366.0 457.0 513.2 439.2 549.8 616.0
309.1 385.8 433.5 386.3 482.3 541.8 463.6 580.4 650.2
325.3 406.1 456.3 406.7 507.7 570.3 488.0 610.9 684.4
No. of fans
Air quantity m3 /s 25.72 24.79 23.92 32.14 30.99 29.90 38.57 37.19 35.88
1 System Intlet OD inch 2 5/8" 2 5/8" 2 5/8" 2 5/8" 3 1/8" 3 1/8" 3 1/8" 3 1/8" 3 1/8"
1 System Outlet OD inch 1 3/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8" 2 1/8" 1 5/8" 2 1/8" 2 1/8"
2 System Inlet OD inch 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 5/8" 2 5/8"
2 System Outlet OD inch 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8"
Coil face area m2
Inter. Coil vol. lit res 44.12 66.17 88.23 54.90 82.35 109.80 65.70 98.55 131.40R22 13.88 20.82 27.12 17.35 26.03 33.90 20.82 30.82 40.68
R404A 15.48 23.21 23.27 19.35 29.02 29.09 23.21 34.36 34.90
R134a 13.19 19.78 27.58 16.48 24.73 34.48 19.78 29.28 41.37
R22 29.4 44.1 58.8 48.8 73.1 97.5 58.4 87.5 116.7
R404A 25.2 37.8 50.4 41.8 62.7 83.7 50.1 75.1 100.1
R134a 29.9 44.8 59.8 49.6 74.4 99.2 59.4 89.0 118.7
17
18
13
14
15
16
Technical & Physical Data
ITD K
1
10
Refrigerant operating
charge kg
Pump - down capacity
kg @ 80%
6
6.10 7.62 9.14
Total Heat Rejection - kW
Model
19
20
11
12
4 5
n
Cu fin 850 1012 1174 1057 1259 1461 1247 1489 1731
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Net mass kg
Altitude correction factors
Example:
Required THR: 320 kWAmbient design condition: 35°CAltitude: 1800mCondensing temperature: 50 °CRefrigerant: R22
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 50°C - 35°C = 15°C
Correction Factor R22 = 1Correction Factor 1800m = 0.88
Required capacity at catalogue conditions:
320 kW ÷ 1 ÷ 0.88 = 363 kW THR required at15°C ITD, Refrigerant R22, Altitude 0m
At 15°C ITD the "HCV-806-2R" gives 366.0 kW
Select the "HCV-806-2R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
19/157
HCV RANGE OF AIR COOLED CONDENSERWITH FLOATING COILS AND 800mm FANS
HCV - 800 - B
Page 4 of 415-07-2011
Note:
- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410Aapplications
Fan:- EC 800mm diameter- 2.56 kW 3.9 A Each.
Coil:- 12mm Rifle bore copper tube- Aluminium fin- 12 fins per inch
Fan Wiring
Motor Diameter Voltage Frequency Speed Power Amperagemm V Hz rpm W A
EC Standard
3 Phase DELTA Optional
Note:
- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410Aapplications
Fan:- EC 800mm diameter- 2.56 kW 3.9 A Each.
Coil:- 12mm Rifle bore copper tube- Aluminium fin- 12 fins per inch
-
8/18/2019 HC Catalog. Evaporators and Condensers
20/157
HCV RANGE OF AIR COOLED CONDENSER
WITH FLOATING COILS AND 800mm FANS
HCV - 800 - A
Page 5 of 5
01-10-2009
Fan Wiring
Motor Diameter Voltage Frequency Speed Power Amperage
mm V Hz rpm W A
EC 800 400 50 1030 2200 3.7 Standard
3 Phase DELTA 800 400 50 896 2000 4.3 Optional
Note: EC Wiring diagram located in appendix C
Note:
subject
to
change
without
notice
NATALP.O Box 30620Mayville, 4058Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENGP.O Box 147Maraisburg, 1700Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIAP.O Box 1301WindhoekTel: (0926461) 261-647Fax: (0926461) 216-201
CAPEP.O Box 36640Chempet, 7442Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
Note:
subject
to
change
without
notice
Page 20
-
8/18/2019 HC Catalog. Evaporators and Condensers
21/157
HC HEAT - EXCHANGERS
V-SHAPED AIR COOLED CONDENSERWITH FLOATING COILS AND 500mm FANS
HVV - 500 - A
Page 1 of 401-10-2009
General Description
The HVV-502 to -5010 range of Air Cooled Condensers comprises 15 models covering duties from 43kWto 287.8kW total heat rejection at 15K ITD. The range of compact units is ideal for minimal footprintapplications.The low noise level modular fan arrangement is well suited to economical fan cycling head pressurecontrol. Each unit is factory wired to a terminal strip in a terminal box. The coil incorporates our floatingcoil construction, eliminating tube failure at the tube plates, with resultant refrigerant loss and thusensures a long and trouble-free service life.
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• RAL-7032 Kiesel grey colour
• Baffled individual fan sections
• Vertical air discharge
• Dual system operation
• 400/3/50 Hz fan motor
• Optional Features
• Copper fin coil
• Coated Al fin coil
• 430 Stainless steel casing
• EC modulating fans
• 230/1/50 Hz fan motor
• Fan cycling head pressure control
• Wire mesh screen
Nomenclature
HC Heat-Exchangers
V Shaped condenser
V = Vertical air flow
Fan diameter -cm
No. of systems
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H V V – 502 – A 4R - 2S
-
8/18/2019 HC Catalog. Evaporators and Condensers
22/157
V-SHAPED AIR COOLED CONDENSERWITH FLOATING COILS AND 500mm FANS
HVV - 500 - A
Page 2 of 401-10-2009
502-2R 502-3R 502-4R 504-2R 504-3R 504-4R 506-2R 506-3R 506-4R
2.9 3.5 3.8 5.7 7.0 7.7 8.6 10.5 11.5
28.7 35.2 38.4 57.2 70.3 76.8 85.8 105.5 115.1
31.6 38.7 42.2 62.9 77.4 84.4 94.3 116.0 126.7
34.4 42.2 46.1 68.6 84.4 92.1 102.9 126.6 138.2
37.3 45.7 49.9 74.3 91.4 99.8 111.5 137.1 149.7
40.2 49.2 53.7 80.1 98.4 107.5 120.1 147.7 161.2
43.0 52.8 57.6 85.8 105.5 115.1 128.7 158.2 172.7
45.9 56.3 61.4 91.5 112.5 122.8 137.2 168.8 184.2
48.8 59.8 65.2 97.2 119.5 130.5 145.8 179.3 195.751.6 63.3 69.1 102.9 126.6 138.2 154.4 189.9 207.3
54.5 66.8 72.9 108.6 133.6 145.8 163.0 200.4 218.8
57.4 70.3 76.8 114.4 140.6 153.5 171.5 211.0 230.3
No. of fans
Air quantity m3 /s 4 .81 4.49 4.18 9.62 8.97 8.36 14.43 13.46 12.54
2 System Inlet OD inch 7/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8"
12
13
15
16
1718
19
20
1
ITD K
10
11
Technical & Physical Data
2 4 6
Model
Total Heat Rejection - kW
14
2 System Outlet OD inch 5/8" 5/8" 5/8" 3/4" 7/8" 7/8" 7/8" 7/8" 1 1/8"
Coil face area m2
Inter. Coil vol. litres 8.74 13.12 17.49 16.24 24.36 32.5 23.7 35.6 47.5
R22 2.34 3.48 4.62 4.76 6.98 9.24 7.14 10.46 13.86
R404A 2.7 4.05 5.4 5.4 8.1 10.8 8.08 12.12 16.16R134a 2.26 3.39 4.52 4.52 6.78 9.04 6.78 10.17 13.56
R22 7.77 11.65 15.54 14.43 21.64 28.85 21.08 31.63 42.2
R404A 6.6 9.9 13.20 12.26 18.39 24.51 17.91 26.87 35.8
R134a 7.9 11.85 15.8 14.67 22 29.3 21.4 32.16 42.9
Al fin 161 145 155 240 259 277 317 345 372
Cu fin 180 173 192 278 315 352 373 429 484
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Total pump - down
capacity kg @ 80%
Net mass kg
Altitude correction factors
Total refrigerant
operating charge kg
1.38 2.76 4.14
Example:
Required THR: 105 kWAmbient design condition: 34°CAltitude: 200mCondensing temperature: 50 °CRefrigerant: R407C
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 50°C - 34°C = 16°C
Correction Factor R407C = 0.87Correction Factor 200m = 0.99
Required capacity at catalogue conditions:
105 kW ÷ 0.87 ÷ 0.99 = 121.9 kW THR required at16°C ITD, Refrigerant R22, Altitude 0m
At 16°C ITD the "HVV-504-4R" gives 122.8 kWSelect the "HVV-504-4R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
23/157
V-SHAPED AIR COOLED CONDENSERWITH FLOATING COILS AND 500mm FANS
HVV - 500 - A
Page 3 of 401-10-2009
508-2R 508-3R 508-4R 5010-2R 5010-3R 5010-4R
11.4 14.1 15.4 14.3 17.6 19.2
114.4 140.7 153.5 142.9 175.8 191.9
125.8 154.7 168.9 157.2 193.4 211.1
137.2 168.8 184.2 171.5 211.0 230.3
148.7 182.8 199.6 185.8 228.5 249.5
160.1 196.9 214.9 200.1 246.1 268.7
171.5 211.0 230.3 214.4 263.7 287.9
183.0 225.0 245.6 228.7 281.3 307.0
194.4 239.1 261.0 243.0 298.9 326.2205.8 253.2 276.3 257.3 316.5 345.4
217.3 267.2 291.7 271.6 334.0 364.6
228.7 281.3 307.1 285.9 351.6 383.8
No. of fans
Air quantity m /s 19.24 17.94 16.72 24.05 22.43 20.9
2 System Inlet OD inch 1 3/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8"
15
16
12
1718
19
20
13
14
8 10
Technical & Physical Data
ITD K
1
10
Model
Total Heat Rejection - kW
11
2 System Outlet OD inch 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8"
Coil face area m
Inter. Coil vol. litres 31.2 46.8 62.5 38.7 58.1 77.5
R22 9.52 13.94 18.48 11.88 17.44 23.1
R404A 10.78 16.17 21.56 13.48 20.22 26.96R134a 9.04 13.56 18.08 11.32 16.98 22.64
R22 27.7 41.6 55.5 34.4 51.6 68.8
R404A 23.6 35.4 47.1 29.2 43.8 58.5
R134a 28.2 42.3 56.4 35.0 52.5 70.0
Al fin 412 448 484 504 548 593
Cu fin 486 560 633 597 688 780
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Total refrigerant
operating charge kg
Total pump - down
capacity kg @ 80%
Net mass kg
Altitude correction factors
5.52 6.90
Capacity Correction
Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
Example:
Required THR: 105 kWAmbient design condition: 34°CAltitude: 200mCondensing temperature: 50 °CRefrigerant: R407C
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 50°C - 34°C = 16°C
Correction Factor R407C = 0.87Correction Factor 200m = 0.99
Required capacity at catalogue conditions:
105 kW ÷ 0.87 ÷ 0.99 = 121.9 kW THR Required at16°C ITD, Refrigerant R22, Altitude 0m
At 16°C ITD the "HVV-504-4R" gives 122.8 kW
Select the "HVV-504-4R"
-
8/18/2019 HC Catalog. Evaporators and Condensers
24/157
V-SHAPED AIR COOLED CONDENSERWITH FLOATING COILS AND 500mm FANS
HVV - 500 - A
Page 4 of 401-10-2009
Note:
- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410A _ applications
1190
3140
1200
1500
3080
Fan Wiring
Motor Diameter Voltage Frequency Speed Power Amperagemm V Hz rpm W A
3 Phase DELTA 500 400 50 1325 820 1.59 StandardEC 500 400 50 1450 1004 1.9 Optional
1 Phase 500 230 50 1270 760 3.3 Optional
NATALP.O Box 30620
Mayville, 4058Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENGP.O Box 147
Maraisburg, 1700Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIAP.O Box 1301
WindhoekTel: (0926461) 261-647Fax: (0926461) 216-201
CAPEP.O Box 36640
Chempet, 7442Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
L1 - BLACKL2 - BLUEL3 - BROWNTOP - PURPLETOP - PINKE - GREEN / YELLOWF1 - FAN MOTOR
L1 L2 L3 TOP
F1
ETOP
an:
AC 500mm diameter400/3/50 Hz0.82 kW 1.59A
Coil:
- 3/8" Rifle bore copper tube- Aluminium fin- 12 fins per inch
HVV 502
HVV 504
HVV 506
HVV 508
HVV 5010
740
1340
1940
2540
3140
NOTE: EC Wiring diagram see Appendix B
-
8/18/2019 HC Catalog. Evaporators and Condensers
25/157
HC HEAT - EXCHANGERS
V-SHAPED AIR COOLED CONDENSER
WITH FLOATING COILS AND 630mm FANS
HVV - 630 - B
Page 1 of 3
01-10-2009
General Descript ion
The HVV-632 to -638 range of Air Cooled Condensers comprises 12 models covering duties from 97.2kW to 556.5 kW total heat rejection at 15K ITD. The range of compact units is ideal for minimal footprintapplications.The low noise level modular fan arrangement is well suited to economical fan cycling head pressurecontrol. Each unit is factory wired to a terminal strip in a terminal box. The coil incorporates our floatingcoil construction, eliminating tube failure at the tube plates, with resultant refrigerant loss and thusensures a long and trouble-free service life.
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• RAL-7032 Kiesel grey colour
• Baffled individual fan sections
• Vertical air discharge
• Dual system operation
• 400/3/50 Hz fan motor
• Optional Features
• Copper fin coils
• Coated Al fin coils
• 430 Stainless steel casing
• Fan cycling head pressure control
• Wire mesh screen
Nomenclature
HC Heat-Exchangers
V Shaped condenser
V = Vertical air flow
Fan diameter -cm
No. of systems
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H V V – 632 – A 4R - 2S
-
8/18/2019 HC Catalog. Evaporators and Condensers
26/157
V-SHAPED AIR COOLED CONDENSER
WITH FLOATING COILS AND 630mm FANS
HVV - 630 - B
Page 2 of 3
01-10-2009
632-2R 632-3R 632-4R 634-2R 634-3R 634-4R 636-2R 636-3R 636-4R 638-2R 638-3R 638-4R
6.5 8.2 9.3 13.0 16.4 18.6 19.4 24.6 27.8 25.9 32.8 37.1
64.8 81.9 92.7 129.7 163.8 185.5 194.5 245.7 278.3 259.3 327.7 371.0
71.3 90.1 102.0 142.6 180.2 204.1 213.9 270.3 306.1 285.2 360.4 408.1
77.8 98.3 111.3 155.6 196.6 222.6 233.4 294.9 333.9 311.1 393.2 445.2
84.3 106.5 120.6 168.6 212.9 241.2 252.8 319.5 361.7 337.0 426.0 482.3
90.7 114.7 129.8 181.5 229.3 259.7 272.3 344.0 389.6 363.0 458.7 519.4
97.2 122.9 139.1 194.5 245.7 278.3 291.7 368.6 417.4 388.9 491.5 556.5
103.7 131.1 148.4 207.5 262.1 296.9 311.1 393.2 445.2 414.8 524.3 593.6
110.2 139.3 157.6 220.4 278.5 315.4 330.6 417.7 473.1 440.8 557.0 630.7116.7 147.5 166.9 233.4 294.8 334.0 350.0 442.3 500.9 466.7 589.8 667.8
123.2 155.7 176.2 246.4 311.2 352.5 369.5 466.9 528.7 492.6 622.6 704.9
129.6 163.9 185.5 259.3 327.6 371.1 388.9 491.5 556.5 518.5 655.3 742.0
No. of fans
Air quantity m3/s 10.68 10.4 10.11 21.36 20.80 20.22 32.04 31.21 30.34 42.73 41.61 40.45
2 System Inlet OD inch 1 3/8" 1 3/8" 1 3/8" 1 5/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 5/8" 2 1/8" 2 5/8" 2 5/8"
15
16
17
18
19
20
14
Total Heat Rejection - kW
1
ITD K
10
11
12
13
Technical & Physical Data
Model
2 4 6 8
2 System Outlet OD inch 7/8" 7/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8"
Coil face area m2
Inter. Coil vol. litres 19.41 29.12 38.82 37.06 55.58 74.1 54.7 82.1 109.4 72.4 108.5 144.7
R22 5.54 8.24 10.8 11.1 16.5 21.6 16.6 24.7 32.52 22.16 32.96 43.36
R404A 6.32 9.38 12.3 12.6 18.7 24.6 16 28.14 36.95 25.28 37.52 49.28R134a 5.32 7.84 10.2 10.6 15.6 20.4 18.9 23.52 30.66 21.28 31.36 40.88
R22 17.2 25.9 34.5 32.9 49.4 65.8 48.6 72.9 97.2 64.3 96.4 128.5
R404A 14.7 22.0 29.3 28.0 42.0 55.9 41.3 61.9 82.6 54.6 81.9 109.2
R134a 17.5 26.3 35.1 33.5 50.2 66.9 49.4 74.1 98.8 65.4 98.0 130.7
Al fin 357 388 419 610 671 732 861 952 1042 1112 1232 1352
Cu fin 435 505 575 767 907 1047 1096 1304 1513 1425 1702 1979
Al t m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88 Altitude correction factors
Refrigerant operating
charge kg
Pump - down capacity
kg @ 80%
Net mass kg
3.05 6.10 9.14 12.19
Example:
Required THR: 450 kW
Ambient design condition: 30°C Altitude: 1800mCondensing temperature: 45 °CRefrigerant: R22
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 45°C - 30°C = 15°C
Correction Factor R22 = 1Correction Factor 1800m = 0.88
Required capacity at catalogue conditions:
450 kW ÷ 1 ÷ 0.88 = 511 kW THR required at
15°C ITD, Refrigerant R22, Altitude 0m
At 15°C ITD the "HVV-638-4R" gives 556.5 kWSelect the "HVV-638-4R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
27/157
V-SHAPED AIR COOLED CONDENSER
WITH FLOATING COILS AND 630mm FANS
HVV - 630 - B
Page 3 of 3
01-10-2009
Note:
- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410A
_ applications
2100
1650
145
4200
Fan Wiring
Motor Diameter Voltage Frequency Speed Power Amperage
mm V Hz rpm W A
3 Phase DELTA 630 400 50 1340 2530 5.2 Standard
3 Phase STAR 630 400 50 1050 1680 2.9 Optional
NATAL
P.O Box 30620Mayville, 4058
Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENG
P.O Box 147Maraisburg, 1700
Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIA
P.O Box 1301Windhoek
Tel: (0926461) 261-647Fax: (0926461) 216-
201
CAPEP.O Box 36640Chempet, 7442
Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
L1 - BLACKL2 - BLUEL3 - BROWNTOP - PURPLETOP - PINKE - GREEN / YELLOWF1 - FAN MOTOR
L1 L2 L3 TOP
F1
ETOP
Fan:
AC 630mm diameter 400/ 3 / 50 Hz.1.62 kW 5.2 A Each.
Coil:
- 12mm Rifle bore copper tube- Aluminium fin- 12 fins per inch
HVV 632
HVV 634
HVV 636
HVV 638
1200
2200
3200
4200
-
8/18/2019 HC Catalog. Evaporators and Condensers
28/157
HC HEAT - EXCHANGERS
V-SHAPED AIR COOLED CONDENSER
WITH FLOATING COILS AND 800mm FANS
HVV - 800 - B
Page 1 of 4
01-10-2009
General Description
The HVV-802 to -808 range of Air Cooled Condensers comprises 12 models covering duties from 121kW to676 kW total heat rejection at 15K ITD. The range of compact units is ideal for minimal footprintapplications.The low noise level modular fan arrangement is well suited to economical fan cycling head pressurecontrol. Each unit is factory wired to a terminal strip in a terminal box. The coil incorporates our floating coilconstruction, eliminating tube failure at the tube plates, with resultant refrigerant loss and thus ensures along and trouble-free service life.
Note:
subject
to
change
without
notice
• Standard Features
• Rifle bore copper tubes
• Aluminium fins
• Galvanised steel casing
• Epoxy powder coated finish
• RAL-7032 Kiesel grey colour
• Baffled individual fan sections
• Vertical air discharge
• Dual system operation
• EC modulating fan
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing
• 400/3/50 Hz Fan motor
• Wire mesh screen
Nomenclature
HC Heat-Exchangers
V Shaped condenser
V = Vertical air flow
Fan diameter -cm
No. of systems
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H V V – 802 – A 4R - 2S
Note:
subject
to
change
without
notice
Page 28
-
8/18/2019 HC Catalog. Evaporators and Condensers
29/157
V-SHAPED AIR COOLED CONDENSER
WITH FLOATING COILS AND 800mm FANS
HVV - 800 - B
Page 2 of 4
01-10-2009
802-2R 802-3R 802-4R 804-2R 804-3R 804-4R 806-2R 806-3R 806-4R 808-2R 808-3R 808-4R8.1 10.1 11.3 16.2 20.2 22.6 24.4 30.3 33.8 32.5 40.4 45.1
81.1 101.1 112.7 162.3 202.1 225.5 243.5 303.2 338.3 324.7 404.3 451.0
89.2 111.2 124.0 178.6 222.3 248.1 267.9 333.5 372.1 357.2 444.7 496.1
97.4 121.3 135.3 194.8 242.6 270.6 292.2 363.8 405.9 389.7 485.1 541.2
105.5 131.4 146.6 211.0 262.8 293.2 316.6 394.2 439.7 422.2 525.5 586.3
113.6 141.5 157.8 227.3 283.0 315.7 340.9 424.5 473.6 454.6 566.0 631.4
121.7 151.6 169.1 243.5 303.2 338.3 365.3 454.8 507.4 487.1 606.4 676.5
129.8 161.7 180.4 259.7 323.4 360.9 389.7 485.1 541.2 519.6 646.8 721.6
137.9 171.8 191.6 276.0 343.6 383.4 414.0 515.4 575.1 552.0 687.3 766.7
146.0 181.9 202.9 292.2 363.8 406.0 438.4 545.8 608.9 584.5 727.7 811.8
154.2 192.0 214.2 308.4 384.1 428.5 462.7 576.1 642.7 617.0 768.1 856.9
162.3 202.1 225.5 324.7 404.3 451.1 487.1 606.4 676.5 649.5 808.5 902.0
No. of fans
Air quantity m3/s 12.88 12.4 11.9 25.7 24.80 23.90 38.70 37.2 35.9 51.5 49.58 47.8
2 System Inlet OD inch 1 3/8" 1 5/8" 1 5/8" 2 1/8" 2 1/8" 2 1/8" 2 1/8" 2 5/8" 2 5/8" 2 5/8" 2 5/8" 2 5/8"
2 System Outlet OD inch 7/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8" 1 3/8" 1 5/8" 1 5/8"
Technical & Physical Data
Model
2 4 6 8
14
Total Heat Rejection - kW
1
ITD K
10
11
12
13
15
16
17
18
19
20
Note:
subject
to
change
without
notice
Coil face area m2
Inter. Coil vol. litres 25.41 38.1 50.80 48.70 73.1 97.4 72.0 108.0 144.0 95.3 142.9 190.6
R22 7.3 10.7 14.3 14.5 21.5 28.6 21.8 32.2 42.9 29.0 43.0 57.2
R404A 8.3 12.3 16.3 16.6 24.6 32.5 24.8 37.0 48.8 33.1 49.3 65.0
R134a 7.0 10.2 13.6 14.0 20.4 27.2 20.9 30.7 40.7 27.9 40.9 54.3
R22 22.6 33.8 45.1 43.3 64.9 86.5 64.0 95.9 127.9 84.6 126.9 169.3
R404A 19.2 28.8 38.3 36.8 55.2 73.5 54.3 81.5 108.7 71.9 107.9 143.9
R134a 23.0 34.4 45.9 44.0 66.0 88.0 65.0 97.6 130.1 86.1 129.1 172.2
Al fin 525 565 606 897 978 1058 1269 1388 1507 1640 1799 1957
Cu fin 628 720 812 1106 1290 1474 1580 1855 2126 2054 2420 2785
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
4.02 8.04 12.07 16.09
Altitude correction factors
Refrigerant operating
charge kg
Pump - down capacitykg @ 80%
Net mass kg
Example:
Required THR: 400 kW Ambient design condition: 30°C Altitude: 1800m
Condensing temperature: 45 °CRefrigerant: R22
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 45°C - 30°C = 15°C
Correction Factor R22 = 1Correction Factor 1800m = 0.88
Required capacity at catalogue conditions:
400 kW ÷ 1 ÷ 0.88 = 454.5 kW THR required at15°C ITD, Refrigerant R22, Altitude 0m
At 15°C ITD the "HVV-806-3R" gives 454.8 kWSelect the "HVV-806-3R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
Note:
subject
to
change
without
notice
Page 29
-
8/18/2019 HC Catalog. Evaporators and Condensers
30/157
V-SHAPED AIR COOLED CONDENSER
WITH FLOATING COILS AND 800mm FANS
HVV - 800 - B
Page 3 of 4
01-10-2009
1953
272
2225
4540
Note:
subject
to
change
without
notice
Note:
- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410A
_ applications
Fan:
EC 800mm diameter 400/3/50 Hz2.2kW x 3.7A Each
Coil:
- 12mm Rifle bore copper tube- Aluminium fin- 12 fins per inch
HVV 802
HVV 804
HVV 806
HVV 808
1240
2340
3440
4540
Note:
subject
to
change
without
notice
Page 30
-
8/18/2019 HC Catalog. Evaporators and Condensers
31/157
V-SHAPED AIR COOLED CONDENSER
WITH FLOATING COILS AND 800mm FANS
HVV - 800 - B
Page 4 of 4
01-10-2009
Fan Wiring
Motor Diameter Voltage Frequency Speed Power Amperage
mm V Hz rpm W A
EC 800 400 50 1030 2200 3.7 Standard
3 Phase DELTA 800 400 50 895 2000 4.3 Optional
Note: EC Wiring diagram located in appendix C
Note:
subject
to
change
without
notice
NATALP.O Box 30620Mayville, 4058Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENGP.O Box 147Maraisburg, 1700Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIAP.O Box 1301WindhoekTel: (0926461) 261-647Fax: (0926461) 216-201
CAPEP.O Box 36640Chempet, 7442Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
Note:
subject
to
change
without
notice
Page 31
-
8/18/2019 HC Catalog. Evaporators and Condensers
32/157
HC HEAT - EXCHANGERS
HAV REMOTE AIR COOLED CONDENSERWITH 350mm FANS
HAV-350-APage 1 of 3
01-10-2009
General Description
The new HAV-351 to 353 range of Remote Air Cooled Condensers comprises 9 models covering dutiesfrom 6.5 kW to 25.2 kW total heat rejection at 15K ITD. The low noise level modular fan arrangement iswell suited to economical fan cycling head pressure control while high efficiency rifle bore tube enhancesperformance. Each unit is factory wired to a terminal strip in a terminal box. The coil incorporates ourfloating coil construction, eliminating tube failure at the tube plates, with resultant refrigerant loss, andensures a long trouble-free service life.
Nomenclature
HC Heat-Exchangers
Air cooled condenser
V=Vertical H=Horizontal
Fan diameter -cm
No. of systems
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H A V – 351 - A - 4R - 1S
• Standard Features
• Rifle bore copper tubes
• Aluminium fin
• Galvanized steel casing
• Floating coil construction
• Vertical or Horizontal air discharge
• CPO-5012 Hammer black color
• 230/1/50 Hz fan motor
• Optional Features
• Copper fin
• Coated Al fins
• 430 Stainless steel casing
• Legs
•400/3/50 Hz fan motor
HAH HAV
-
8/18/2019 HC Catalog. Evaporators and Condensers
33/157
HAV REMOTE AIR COOLED CONDENSERWITH 350mm FANS
HAV-350-APage 2 of 3
01-10-2009
351-2R 351-3R 351-4R 352-2R 352-3R 352-4R 353-2R 353-3R 353-4R
0.4 0.5 0.6 0.9 1.0 1.1 1.3 1.6 1.7
4.3 5.2 5.6 8.7 10.5 11.2 13.1 15.7 16.8
4.8 5.7 6.2 9.6 11.5 12.3 14.4 17.2 18.5
5.2 6.2 6.7 10.5 12.6 13.4 15.7 18.8 20.1
5.6 6.8 7.3 11.3 13.6 14.5 17.0 20.3 21.8
6.1 7.3 7.9 12.2 14.7 15.7 18.3 21.9 23.5
6.5 7.8 8.4 13.1 15.7 16.8 19.6 23.5 25.2
6.9 8.3 9.0 14.0 16.7 17.9 20.9 25.0 26.9
7.4 8.8 9.5 14.8 17.8 19.0 22.2 26.6 28.57.8 9.4 10.1 15.7 18.8 20.1 23.6 28.2 30.2
8.2 9.9 10.7 16.6 19.9 21.3 24.9 29.7 31.9
8.7 10.4 11.2 17.4 20.9 22.4 26.2 31.3 33.6
No. of fans
Air quantity m3 /s 0.708 0.645 0.594 1.42 1.29 1.19 2.123 1.94 1.781
1 System Inlet OD inch 5/8" 5/8" 5/8" 3/4" 3/4" 7/8" 7/8" 7/8" 7/8"
32
Technical & Physical Data
1
14
ITD K
10
11
12
13
Model
Total Heat Rejection - kW
15
16
17
18
19
20
1
1 System Outlet OD inch 1/2" 1/2" 1/2" 1/2" 5/8" 5/8" 5/8" 5/8" 5/8"
Coil face area m2
Inter. Coil vol. liters 1.50 2.25 3.00 2.80 4.19 5.59 4.09 6.14 8.19
R22 0.40 0.59 0.76 0.78 1.15 1.55 1.18 1.75 2.32
R404A 0.44 0.67 0.88 0.90 1.33 1.76 1.35 2.00 2.64R134a 0.39 0.55 0.72 0.75 1.11 1.45 1.13 1.67 2.17
R22 1.33 2.00 2.67 2.49 3.72 4.97 3.63 5.46 7.28
R404A 1.13 1.69 2.26 2.11 3.16 4.21 3.08 4.63 6.17
R134a 1.36 2.03 2.71 2.53 3.79 5.05 3.70 5.55 7.40
Net mass kg Al fin 22 23 25 41 44 51 59 64 73
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Refrigeration Densities @ 44°C
kg/m3
kg/l
R12 1238.1 1.2381
R22 1110.6 1.1106
R134a 1129.5 1.1295
R404A 941.6 0.9416
R507 940.5 0.9405
0.23 0.690.46
Density
Condenser refrigerant
operating charge kg
Total Pump - down
capacity kg @ 80%
Altitude correction factors
Example:
Required THR: 19 kWAmbient design condition: 30°CAltitude: 200m
Condensing temperature: 45°CRefrigerant: R134a
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 45°C - 30°C = 15 °C
Correction Factor R134a= 0.98Correction Factor 200m = 0.99
Required capacity at catalogue conditions:
19 kW ÷ 0.98 ÷ 0.99 = 19.58 kW THR required at15°C ITD, Refrigerant R22, Altitude 0m
At 15°C ITD the "HAV-353-2R" gives 19.6 kWSelect the "HAV-353-2R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
34/157
HAV REMOTE AIR COOLED CONDENSERWITH 350mm FANS
HAV-350-APage 3 of 3
01-10-2009
30 30
30
300
13060
1690
430
500
1000
1500
HAV 351
HAV 352
HAV 353
Fan WiringMotor
AC
AC
Standard
rpm
W
Optional
Amperage
mm
V
Hz
A
Diameter Voltage Frequency Speed Power
NATALP.O Box 30620Mayville, 4058
Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENGP.O Box 147Maraisburg, 1700
Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIAP.O Box 1301Windhoek
Tel: (0926461) 261-647Fax: (0926461) 216-201
CAPEP.O Box 36640Chempet, 7442
Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
30
517457
Note:
- Dimensions in mm- Dimensions ± 2 mm- Refer to manufacturer for R410A _ applications
L1 N E
F1
L - BLUEN - BROWNE - GREEN / YELLOWF1 - FAN MOTOR
Note:
Fan:AC 350mm diameter0.132 kW 0.58 A Each.
Coil:- 3/8" Rife bore copper tube- Aluminium fin- 12 fins per inch
-
8/18/2019 HC Catalog. Evaporators and Condensers
35/157
HC HEAT - EXCHANGERS
HAV REMOTE AIR COOLED CONDENSER
WITH 400mm FANS
HAV-400-A
Page 1 of 3
01-10-2009
General Description
The new HAV-401 to 403 range of Remote Air Cooled Condensers comprises 9 models covering duties from9.5 kW to 37.2 kW total heat rejection at 15K ITD. The low noise level modular fan arrangement is well suitedto economical fan cycling head pressure control while high efficiency rifle bore tube enhances performance.Each unit is factory wired to a terminal strip in a terminal box. The coil incorporates our floating coilconstruction, eliminating tube failure at the tube plates, with resultant refrigerant loss, and ensures a longtrouble-free service life.
Note:
subject
to
change
without
notice
Nomenclature
HC Heat-Exchangers
Air cooled condenser
V=Vertical H=Horizontal
Fan diameter -cm
No. of systems
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H A V – 401 - A - 4R - 1S
• Standard Features
• Rifle bore copper tubes
• Aluminium fin
• Galvanized steel casing
• Floating coil construction
• Vertical or Horizontal air discharge
• CPO-5012 Hammer black color
• 400/3/50 Hz fan motor
• Optional Features
• Copper fin
• Coated Al fins
• 430 Stainless steel casing
• Legs
•400/3/50 Hz fan motor
HAH HAV
Note:
subject
to
change
without
notice
Page 35
-
8/18/2019 HC Catalog. Evaporators and Condensers
36/157
HAV REMOTE AIR COOLED CONDENSER
WITH 400mm FANS
HAV-400-A
Page 2 of 3
01-10-2009
401-2R 401-3R 401-4R 402-2R 402-3R 402-4R 403-2R 403-3R 403-4R0.6 0.8 0.8 1.3 1.5 1.7 1.9 2.3 2.5
6.3 7.6 8.3 12.6 15.3 16.5 19.0 22.9 24.8
7.0 8.4 9.1 13.9 16.8 18.2 20.9 25.2 27.3
7.6 9.2 9.9 15.1 18.3 19.9 22.8 27.5 29.8
8.3 9.9 10.8 16.4 19.9 21.5 24.7 29.8 32.3
8.9 10.7 11.6 17.7 21.4 23.2 26.6 32.1 34.7
9.5 11.5 12.4 18.9 22.9 24.8 28.5 34.4 37.2
10.2 12.2 13.2 20.2 24.4 26.5 30.4 36.7 39.7
10.8 13.0 14.1 21.4 26.0 28.1 32.3 39.0 42.2
11.4 13.7 14.9 22.7 27.5 29.8 34.2 41.2 44.7
12.1 14.5 15.7 24.0 29.0 31.4 36.1 43.5 47.2
12.7 15.3 16.6 25.2 30.5 33.1 38.0 45.8 49.6
No. of fans
Air quantity m3/s 0.979 0.916 0.858 1.96 1.83 1.72 2.936 2.75 2.575
1 System Inlet OD inch 5/8" 5/8" 3/4" 3/4" 7/8" 7/8" 7/8" 1 1/8" 1 1/8"
1 System Outlet OD inch 1/2" 1/2" 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4"
Model
Total Heat Rejection - kW
15
16
17
18
19
20
1
Technical & Physical Data
1
14
ITD K
10
11
12
13
32
Note:
subject
to
change
without
notice
Coil face area m2
Inter. Coil vol. liters 2.52 3.63 4.84 4.49 6.74 8.99 6.57 9.85 13.14
R22 0.62 0.93 1.23 1.27 1.86 2.47 1.87 2.79 3.70
R404A 0.71 1.06 1.41 1.43 2.13 2.80 2.15 3.20 4.20
R134a 0.60 0.89 1.14 1.19 1.77 2.33 1.79 2.66 3.50
R22 2.24 3.23 4.30 3.99 5.99 7.99 5.84 8.75 11.67
R404A 1.90 2.73 3.65 3.38 5.08 6.77 4.95 7.42 9.90
R134a 2.28 3.28 4.37 4.06 6.09 8.12 5.94 8.90 11.87
Net mass kg Al fin 29 32 34 56 61 71 80 87 103
Al t m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Refrigeration Densities @ 44°C
kg/m3
kg/l
R12 1238.1 1.2381
R22 1110.6 1.1106
R134a 1129.5 1.1295
R404A 941.6 0.9416
R507 940.5 0.9405
Altitude correction factors
Condenser refrigerant
operating charge kg
Total Pump - downcapacity kg @ 80%
0.37 1.100.73
Density
Example:
Required THR: 22 kW Ambient design condition: 30°C Altitude: 200mCondensing temperature: 45°CRefrigerant: R134a
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 45°C - 30°C = 15 °C
Correction Factor R134a= 0.98Correction Factor 200m = 0.99
Required capacity at catalogue conditions:
22 kW ÷ 0.98 ÷ 0.99 = 22.67 kW THR required at15°C ITD, Refrigerant R22, Altitude 0m
At 15°C ITD the "HAV-402-3R" gives 22.9 kWSelect the "HAV-402-3R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03
R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
Note:
subject
to
change
without
notice
Page 36
-
8/18/2019 HC Catalog. Evaporators and Condensers
37/157
HAV REMOTE AIR COOLED CONDENSER
WITH 400mm FANS
HAV-400-A
Page 3 of 3
01-10-2009
30 30
300
60130
1990
430
INOUT
670600
1800
HAV 401
HAV 402
HAV 403
1200
Note:
subject
to
change
without
notice
Fan WiringMotor
AC
AC
Diameter Voltage Frequency Speed Power Amperage
mm
400
V
400
Hz
50
A
0.76 Standard
rpm
1450
W
135
Optional400 230 50 1430 160 0.73
NATALP.O Box 30620Mayville, 4058Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENGP.O Box 147Maraisburg, 1700Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIAP.O Box 1301WindhoekTel: (0926461) 261-647Fax: (0926461) 216-201
CAPEP.O Box 36640Chempet, 7442Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
Note:
- Dimensions in mm
- Dimensions ± 2 mm- Refer to manufacturer for R410A _ applications
Note:
Fan: AC 400mm diameter 0.135 kW 0.76 A Each.
Coil:- 3/8" Rife bore copper tube- Aluminium fin- 12 fins per inch
Note:
subject
to
change
without
notice
Page 37
-
8/18/2019 HC Catalog. Evaporators and Condensers
38/157
-
8/18/2019 HC Catalog. Evaporators and Condensers
39/157
REMOTE AIR COOLED CONDENSERWITH 500mm FANS
HAV-500-APage 2 of 3
01-10-2009
501-2R 501-3R 501-4R 502-2R 502-3R 502-4R 503-2R 503-3R 503-4R
1.3 1.6 1.8 2.7 3.3 3.5 4.0 4.9 5.3
13.4 16.3 17.7 26.8 32.6 35.4 40.1 48.9 53.1
14.8 17.9 19.5 29.4 35.9 38.9 44.1 53.8 58.4
16.1 19.6 21.2 32.1 39.1 42.5 48.1 58.7 63.7
17.5 21.2 23.0 34.8 42.4 46.0 52.2 63.6 69.0
18.8 22.8 24.8 37.5 45.6 49.5 56.2 68.5 74.3
20.1 24.4 26.5 40.1 48.9 53.1 60.2 73.3 79.6
21.5 26.1 28.3 42.8 52.2 56.6 64.2 78.2 84.9
22.8 27.7 30.1 45.5 55.4 60.1 68.2 83.1 90.224.2 29.3 31.8 48.2 58.7 63.7 72.2 88.0 95.5
25.5 31.0 33.6 50.8 61.9 67.2 76.2 92.9 100.8
26.9 32.6 35.4 53.5 65.2 70.8 80.2 97.8 106.1
No. of fans
Air quantity m3 /s 2.319 2.126 2.261 4.64 4.25 3.91 6.956 6.38 5.86
1 System Intlet OD inch 3/4" 7/8" 7/8" 7/8" 1 1/8" 1 1/8" 1 1/8" 1 3/8" 1 3/8"
Model
Total Heat Rejection - kW
15
16
17
18
19
20
1
Technical & Physical Data
1
14
ITD K
10
11
12
13
32
1 System Outlet OD inch 5/8" 5/8" 5/8" 5/8" 3/4" 7/8" 7/8" 1 1/8" 1 1/8"
Coil face area m2
Inter. Coil vol. litres 3.71 5.56 7.42 7.08 10.62 14.16 10.45 15.68 20.90
R22 1.01 1.51 2.01 2.06 3.03 4.02 3.09 4.54 6.03
R404A 0.71 1.06 1.41 1.43 2.13 2.80 2.15 3.20 4.20R134a 0.99 1.46 1.92 1.98 2.91 3.78 2.96 4.36 5.67
R22 3.30 4.94 6.59 6.29 9.44 12.58 9.28 13.93 18.57
R404A 1.17 1.74 2.30 2.33 3.48 4.60 3.50 5.22 6.89
R134a 3.35 5.02 6.70 6.40 9.60 12.79 9.44 14.17 18.89
Net mass kg Al fin 47 51 55 92 100 117 133 145 170
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Refrigeration Densities @ 44°C
kg/m3
kg/L
R12 1238.1 1.2381
R22 1110.6 1.1106
R134a 1129.5 1.1295
R404A 941.6 0.9416
R507 940.5 0.9405
Altitude correction factors
Condensor refrigerant
operating charge kg
Total Pump - down
capacity kg @ 80%
0.59 1.781.19
Density
Example:
Required THR: 38 kWAmbient design condition: 30°CAltitude: 200m
Condensing temperature: 45°CRefrigerant: R134a
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 45°C - 30°C = 15 °C
Correction Factor R134a= 0.98Correction Factor 200m = 0.99
Required capacity at catalogue conditions:
38 kW ÷ 0.98 ÷ 0.99 = 39.16 kW THR required at15°C ITD, Refrigerant R22, Altitude 0m
At 15°C ITD the "HAV-502-2R" gives 40.1 kWSelect the "HAV-502-2R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
-
8/18/2019 HC Catalog. Evaporators and Condensers
40/157
REMOTE AIR COOLED CONDENSERWITH 500mm FANS
HAV-500-APage 3 of 3
01-10-2009
30 30
300
60
130
2530
430
IN OUT
822780
2340
HAV 501
HAV 502
HAV 503
1560
Fan WiringMotor
AC
AC
Diameter Voltage Frequency Speed Power Amperage
mm
500
V
400
Hz
50
A
1.65 Standard
rpm
1330
W
830
Optional500 230 50 1270 760 3.3
NATALP.O Box 30620Mayville, 4058
Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENGP.O Box 147Maraisburg, 1700
Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIAP.O Box 1301Windhoek
Tel: (0926461) 261-647Fax: (0926461) 216-201
CAPEP.O Box 36640Chempet, 7442
Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
Note:
- Dimensions in mm- Dimansions ± 2 mm- Refer to manufacturer for R410A _ applications
Note:
Fan:AC 500mm diameter0.82 kW 1.59 A Each.
Coil:- 3/8" Rife bore copper tube- Aluminium fin- 12 fins per inch
L1 - BLACKL2 - BLUEL3 - BROWNTOP - PURPLETOP - PINKE - GREEN / YELLOWF1 - FAN MOTOR
L1 L2 L3 TOP
F1
ETOP
-
8/18/2019 HC Catalog. Evaporators and Condensers
41/157
HC HEAT - EXCHANGERS
HCB AIR COOLED CONDENSER BASE
WITH RECEIVER AND 200mm FANS
HCB-200-A
Page 1 of 3
01-10-2009
General Description
The HCB-201-2R to HCB-201-4R comprises 3 models covering duties from 0.92kW to 1.14kW total heatrejection at 15K ITD. Features include our strengthened header connections and high efficiency rifle boretube.
The rugged design of the base allows for easy handling and ready fitment of compressors, HP/LP bracketsetc.
Note:
subject
to
change
without
notice
• Standard Features
• Rifle bore copper tubes
• Aluminium fin
• Galvanized steel casing
• 230/1/50 Hz fan motor
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing
Nomenclature
HC Heat-Exchangers
Air cooled condenser
Base
Fan diameter -cm
Fins per inch (12F)
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H C B – 201 - A - 4R - 12F
Note:
subject
to
change
without
notice
Page 41
-
8/18/2019 HC Catalog. Evaporators and Condensers
42/157
HCB AIR COOLED CONDENSER BASE
WITH RECEIVER AND 200mm FANS
HCB-200-A
Page 2 of 3
01-10-2009
No. of fans
Air quantity m3/s
1 System Inlet OD inch
1 System Outlet OD inch
15
16
17
18
19
20 1.22
1
1.21
Technical & Physical Data
1
14
ITD K
10
11
12
13
0.73
Total Heat Rejection - kW
0.79
201-4R201-3R201-2R0.06
0.61
0.67
0.85
0.92
0.98
1.04
1.10
1.16
0.07
0.71
0.79
0.86
0.93
1.00
0.76
0.84
0.91
0.99
1.06
1.14
1.22
1.29
1.37
1.45
1.52
Model
1.29
1.36
1.43
0.08
1.07
1.14
3/8"
3/8"
0.08
3/8"
3/8"
0.08
3/8"
3/8"
0.09
Note:
subject
to
change
without
notice
Coil face area m2
Inter. Coil vol. liters
Inter. Receiver vol. liters
R22
R404A
R134a
R22
R404A
R134a
Net mass kg Al fin
Alt m 0 200 400 600 800 1000 1200 1400 1600 1800
Factor 1.00 0.99 0.97 0.96 0.95 0.93 0.92 0.91 0.90 0.88
Refrigeration Densities @ 44°C
kg/m3
kg/l
R12 1238.1 1.2381
R22 1110.6 1.1106
R134a 1129.5 1.1295
R404A 941.6 0.9416
R507 940.5 0.9405
Altitude correction factors
Density
Condenser refrigerant
operating charge kg
Total Pump - down
capacity kg @ 80%
0.14
0.15
1.05
1.26
0.72
0.86
1.04
0.88
6.77
0.67
0.50
0.19
0.20
0.170.12
0.84
0.45
0.50
8.00
0.06
1.06
7.56
0.89
0.50
0.25
0.27
0.22
1.23
Example:
Required THR: 0.75kW Ambient design condition: 33°C Altitude: 200mCondensing temperature: 45°C
Refrigerant: R134a
ITD (Initial Temperature Difference)ITD = Condensing Temperature - Ambient TemperatureITD = 45°C - 33°C = 12 °C
Correction Factor R134a= 0.98Correction Factor 200m = 0.99
Required capacity at catalogue conditions:
0.75 kW ÷ 0.98 ÷ 0.99 = 0.77 kW THR required at12°C ITD, Refrigerant R22, Altitude 0 m
At 12°C ITD the "HCB-201-3R" gives 0.86 kWSelect the "HCB-201-3R"
Capacity Correction Factors:
R134a: multiply kW by 0.98R22: multiply kW by 1.00R507: multiply kW by 1.03
R404A: multiply kW by 1.03R407C: multiply kW by 0.87R410A: multiply kW by 1.09
Note:
subject
to
change
without
notice
Page 42
-
8/18/2019 HC Catalog. Evaporators and Condensers
43/157
HCB AIR COOLED CONDENSER BASE
WITH RECEIVER AND 200mm FANS
HCB-200-A
Page 3 of 3
01-10-2009
A [mm]
201-2R 201-3R 201-4R
85 110 130
Note:
- Dimensions in mm
275 A
380
235
2 0
Note:
subject
to
change
without
notice
Fan WiringMotor
AC
Diameter Voltage Frequency Speed Power Amperage
mm
200
V
230
Hz
50
A
0.2 Standard
rpm
1300
W
31
NATALP.O Box 30620Mayville, 4058Tel: (+27 31) 202-7829Fax: (+27 31) 202-7849
GAUTENGP.O Box 147Maraisburg, 1700Tel: (+27 11) 674-1237Fax: (+27 11) 674-1268
NAMIBIAP.O Box 1301WindhoekTel: (0926461) 261-647Fax: (0926461) 216-201
CAPEP.O Box 36640Chempet, 7442Tel: (+27 21) 551-7873Fax: (+27 21) 551-1751
- Dimensions ± 2 mm- Refer to manufacturer for R410A _ applications
Fan:200mm diameter 0.31 kW 0.2 A Each.
Coil:- 3/8" Rifle bore copper tube- Aluminium fin- 12 fins per inch
L1 N E
F1
L - BLUEN - BROWNE - GREEN / YELLOWF1 - FAN MOTOR
330
95
Note:
subject
to
change
without
notice
Page 43
-
8/18/2019 HC Catalog. Evaporators and Condensers
44/157
HC HEAT - EXCHANGERS
HCB AIR COOLED CONDENSER BASE
WITH RECEIVER AND 250mm FANS
HCB-250-B
Page 1 of 3
01-10-2009
General Description
The HCB-251-B-2R to HCB-252-B-4R comprises 6 models covering duties from 1.6 kW to 4.1 kW total heatrejection at 15K ITD. Features include our strengthened header connections and high efficiency rifle boretube.
The rugged design of the base allows for easy handling and ready fitment of compressors, HP/LP bracketsetc.
Note:
subject
to
change
without
notice
Nomenclature
HC Heat-Exchangers
Air cooled condenser
Base
Fan diameter -cm
Fins per inch (12F)
No. of coil rows (2, 3 or 4 row)
Vintage
No. of fans
H C B – 251 - B - 4R - 12F
• Standard Features
• Rifle bore copper tubes
• Aluminium fin
• Galvanized steel casing and base
• Epoxy powder coated finish
• RAL 5005 Signal blue color
• 230/1/50 Hz fan motor
• Optional Features
• Copper fins
• Coated Al fins
• 430 Stainless steel casing
Note:
subject
to
change
without
notice
Page 44
-
8/18/2019 HC Catalog. Evaporators and Condensers
45/157
HCB AIR COOLED CONDENSER BASE
WITH RECEIVER AND 250mm FANS
HCB-250-B
Page 2 of 3
01-10-2009
No. of fans
Air quantity m3/s
1 System Inlet OD inch
1 System Outlet OD inch
Model
Total Heat Rejection - kW
3/8"
3/8"
0.15
3/8"
3/8"
0.14
3/8"
3/8"
0.18
2.53
2.67
2.28
2.41
2.53
1.90
2.03
1.60
1.73
1.87
2.13
2.27
2.40
2.00
0.13
1.27
1.39
1.52
1.65
1.77
0.13
1.33
1.47
1.49
1.60
1.71
1.81
1.92
2.03
1.39
251-4R251-3R251-2R0.11
1.07
1.17
Technical & Physical Data
1
14
ITD K
10
11
12
13
1.28
252-2R
15
16
17
18
19
20 2.13
1
2.15
252-3R 252-4R0.23 0.27 0.27
2.33 2.67 2.73
2.57 2.93 3.01
2.80 3.20 3.28