harvest the sunshine - portal.segensolar.co.zak)(bk)(se)-60 265-285 4bb.pdfjam6(k)(bk)(se)...

4
www.jasolar.com JAM6(K)(BK)(SE)-60/265-285/4BB Harvest the Sunshine Premium Cells, Premium Modules Smart Module 100% Communication 20% More Energy

Upload: others

Post on 02-Mar-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Harvest the Sunshine - portal.segensolar.co.zaK)(BK)(SE)-60 265-285 4BB.pdfJAM6(K)(BK)(SE) Current-Voltage Curve (JAM6(K)(BK)(SE)-60-270/4BB) 0 1 2 3 4 5 6 7 8 9 1 0 0 10 20 30 40

www.jasolar.com

JAM6(K)(BK)(SE)-60/265-285/4BB

Harvest the SunshinePremium Cells, Premium Modules

Smart Module100% Communication20% More Energy

Page 2: Harvest the Sunshine - portal.segensolar.co.zaK)(BK)(SE)-60 265-285 4BB.pdfJAM6(K)(BK)(SE) Current-Voltage Curve (JAM6(K)(BK)(SE)-60-270/4BB) 0 1 2 3 4 5 6 7 8 9 1 0 0 10 20 30 40

JA 4BB design module reduce cell series resistance and stress

between cell interconnectors improves module reliability and module

conversion ef�ciency

5400Pa

BL

AC

K

-60/265-285/4BBJAM6(K)(BK)(SE)

www.jasolar.com

Product Warranty10-year product warranty25-year linear power warranty

JA Solar Holdings Co., Ltd.

1 5 10 15 20 25Year

Added Value From Warranty

100%97%

90%

80%

JA Solar Holdings Co.,Ltd is a world leading manufacturer of high-performance solar power products that convert sunlight into electricity for residential, commercial and utility-scale power generation. The company was founded in May 2005 and publicly listed on NASDAQ in February 2007. JA Solar has been the world's leading cell producer since 2010, and has firmly established itself as a tier 1 module supplier since 2012. Capitalizing on our strength in solar cell technology, we are committed to provide modules with unparalleled conversion efficiency, yield efficiency, and reliability to enable you to maximize your returns on PV projects. With its leading industry experience, continuous effort on R&D, customer-oriented service and sound financial status, JA Solar is your best choice of long-term trustworthy partner.

Partner Section

Additional Insurance Options

Add : NO.36, Jiang Chang San Road, Zhabei, Shanghai 200436, ChinaTel : +86 21 6095 5888 / +86 21 6095 5999Fax:+86 21 6095 5858 / +86 21 6095 5959Email : [email protected] [email protected]

PowerGuard®

SPECIALTY INSURANCE SERVICES

SOLARSOLARI N S U R A N C E & F I N A N C E

MONOCRYSTALLINE SILICON MODULE

Key Features

Automatic module shut-down Unique electrocution prevention and �re safety

Excellent mechanical load resistance: Certi�ed to withstand

high wind loads (2400Pa) and snow loads (5400Pa)

Flexible system design optimal site space utilization at reduced cost

Real-time alerts module-level web monitoring Increased uptime maintenance

Maximum energy gain ground mounted system: 2-5%,

commercial 2-10%, residential 2-25%

Reliable Quality

Comprehensive Certi�cates

IEC 61215, IEC 61730, MCS and CE

ISO 9001: 2008: Quality management systems

ISO 14001: 2004: Environmental management systems

BS OHSAS 18001: 2007: Occupational health and safety management systems

Environmental policy: The �rst solar company in China to complete Intertek's carbon footprint evaluation program and receive green leaf mark veri�cation for our products

Positive power tolerance: 0~+5W

100% EL double-inspection ensures modules are defects free

Potential Induced Degradation (PID) Resistant

Speci�cations subject to technical changes and tests. JA Solar reserves the right of �nal interpretation.

Page 3: Harvest the Sunshine - portal.segensolar.co.zaK)(BK)(SE)-60 265-285 4BB.pdfJAM6(K)(BK)(SE) Current-Voltage Curve (JAM6(K)(BK)(SE)-60-270/4BB) 0 1 2 3 4 5 6 7 8 9 1 0 0 10 20 30 40

Power Optimizer Inverter

Module embedded

Monitoring Portal

Monitoring Server

System Architecture

JA smart system components work together with any inverter to maximize energy harvest. JA smart modules can communicate by electrical line, allowing

users to monitor system performance in real time.

-60/265-285/4BBJAM6(K)(BK)(SE)

Vdc

Vdc

Adc

Adc

Vdc

10

1

5-60

5-Voc of module

15

EN50548 (TUV-SUD), UL3730 (TUV-Rheinland & CSA)

VDE-AR-E 2100-712:2013-05

IEC62109-1 (class II safey, TUV-SUD), UL1741 (TUV-Rheinland & CSA)

Maximum Output Current when connected to Non-SolarEdge Inverter

Output in Standby mode with SolarEdge inverter or with SMI and Non-SolarEdge inverter

(when disconnected from inverter or inverter off)

Output Voltages and Currents

Operating Output Voltage when connected to SolarEdge Inverter

Operating Output Voltage when connected to Non-SolarEdge Inverter

Maximum Output Current when connected to SolarEdge Inverter

PV Junction Box

Standard Compliance

Fire Safety

PV Junction Box Safety

265 270 275 280 285Module Power

String Lengths (computed automatically by SolarEdge Site Designer)

1ph

3ph

3ph-MV

3ph-MV

1ph 19 19 18 18

3ph 42

48 46 45 44

19

47

41 40 40 39

According to inverter design rulesString size with Non-SolarEdge

MINIMUM string size

with SolarEdge inverter

MAXIMUM string size

with SolarEdge inverter

8

16

18

Page 4: Harvest the Sunshine - portal.segensolar.co.zaK)(BK)(SE)-60 265-285 4BB.pdfJAM6(K)(BK)(SE) Current-Voltage Curve (JAM6(K)(BK)(SE)-60-270/4BB) 0 1 2 3 4 5 6 7 8 9 1 0 0 10 20 30 40

JAM6(K)(BK)(SE)

Current-Voltage Curve (JAM6(K)(BK)(SE)-60-270/4BB)

01

23

45

67

89

10

0 10 20 30 40

65℃ 45℃25℃5℃

Current-Voltage Curve (JAM6(K)(BK)(SE)-60-270/4BB)

1000W/m2

01

23

45

67

89

10

0 10 20 30 40

200W/m2

600W/m2

400W/m2

800W/m2

Power-Voltage Curve (JAM6(K)(BK)(SE)-60-270/4BB)

05

01

00

15

02

00

25

03

00

0 10 20 30 40

1000W/m2

800W/m2

600W/m2

400W/m2

200W/m2

Mono 156.75×156.75

19.0±0.5

1650×991×40

6

60 (6×10)

Solar edge smart J-Box

MC4

26 Per Pallet

-40℃~+85℃

15A

5400Pa (112 Ib/ft2)2400Pa (50 Ib/ft2)

45±2℃

Class A

-60/265-285/4BB

JAM6(K)(BK)(SE) -60-265/4BB

JAM6(K)(BK)(SE) -60-270/4BB

JAM6(K)(BK)(SE) -60-275/4BB

JAM6(K)(BK)(SE) -60-280/4BB

JAM6(K)(BK)(SE) -60-285/4BB

JAM6(K)(BK)(SE) -60-265/4BB

JAM6(K)(BK)(SE) -60-270/4BB

JAM6(K)(BK)(SE) -60-275/4BB

JAM6(K)(BK)(SE) -60-280/4BB

JAM6(K)(BK)(SE) -60-285/4BB

JA Solar 09.2015

DC 1000V (IEC)

NOCT

-0~+5W

+0.059%/℃

-0.330%/℃

-0.410%/℃

265

38.23

30.42

9.17

8.71

16.21

270

38.39

30.68

9.29

8.80

16.51

275

38.52

30.80

9.38

8.93

16.82

280

38.65

30.97

9.49

9.04

17.12

285

38.78

31.15

9.58

9.15

17.43

204.68

35.77

28.71

7.48

7.13

208.34

35.97

28.90

7.56

7.21

193.72

34.94

28.03

7.28

6.91

197.37

35.20

28.32

7.35

6.97

201.03

35.50

28.51

7.41

7.05

Engineering Drawings

Junction Box

Label

Draining Holes8 places

Mounting holes8 places

Grounding holes2 places

MECHANICAL PARAMETERS

Cell (mm)

Weight (kg)

Dimensions (L×W×H) (mm)

Cable Cross Section Size (mm2)

No. of Cells and Connections

Junction Box

Connector

Packaging Con�guration

WORKING CONDITIONS

Maximum System Voltage

Operating Temperature

Maximum Series Fuse

Maximum Static Load, Front (e.g., snow and wind)Maximum Static Load, Back (e.g., wind)

NOCT

Application Class

ELECTRICAL PARAMETERS

TYPE

Rated Maximum Power at STC (W)

Open Circuit Voltage (Voc/V)

Maximum Power Voltage (Vmp/V)

Short Circuit Current (Isc/A)

Maximum Power Current (Imp/A)

Module Ef�ciency [%]

Power Tolerance (W)

Temperature Coef�cient of Isc (αIsc)

Temperature Coef�cient of Voc (βVoc)

Temperature Coef�cient of Pmax (γPmp)

STC Irradiance 1000W/m2, Cell Temperature 25℃, Air Mass 1.5

Max Power at STC (Pmax) [W]

Open Circuit Voltage (Voc) [V]

Max Power Voltage (Vmp) [V]

Short Circuit Current (Isc) [A]

Max Power Current (Imp) [A]

TYPE

Condition Under Normal Operating Cell Temperature, Irradiance of 800 W/m2 , spectrum AM 1.5, ambient temperature 20℃, wind speed 1 m/s

Electrical data in this catalog do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types.

I-V CURVE

Voltage (V)

Cur

rent

(A)

Voltage (V)

Pow

er (W

)

Voltage (V)

Cur

rent

(A)