harting profinet type a cable 4-wire cat. 5 pvc · 09 45 600 01x0 technical characteristics harting...
TRANSCRIPT
09 4
5 60
0 01
X0
09 45 600 013009 45 600 014009 45 600 010009 45 600 0110
HARTING PROFINET Type A Cable 4-wire Cat. 5 PVC
Advantages General
Identification Part number Drawing
• SuitableforPROFINETcablingCategory5/ClassDaccordingtoISO/IEC11801respectivelyEN50173-1andISO/IEC24702respectively EN 50 173-3
• Capableforfixinstallation
• Applicableforindustrialpremises
• RoHSconform,ULlisted,flameretardant
This data cable is suitable for PROFINET cabling according to type A in industrial premises and ar-eas. It is useable for fix installation. The core isfitted with 4 wires twisted to quad that allows the transmission of Fast Ethernet 10/100Mbit/s.
It is designed for fast assembling with the easy-stripping tool and can be assembled with all HARTING 4-pole RJ45 connectors.
PROFINET Type A Cable4-wire,Cat.5,PVC
PROFINET Type A Cable4-wire,Cat.5,PVC
20m ring 50 m ring 100 m ring 500 m reel
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
• Wire:SolidbarecopperAWG22/1• Insulation:PEØ1.5mm• Innersheath:Polyvinylchloride(PVC)• Overallscreen:Aluminatefoiloverlapped,tinned
copperwirebraid,braidcoverageabout90%• Outersheath:Polyvinylchloride(PVC),flame
retardantColorcode:wh,ye,bu,orColorofinnersheath:whiteColorofoutersheath:green,RAL6018Overalldiameter:6.3mm–6.7mm
09 4
5 60
0 01
X0 Technical Characteristics
HARTING PROFINET Type A Cable 4-wire Cat. 5 PVC
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
Performance Category5accordingtoEN50288-2-1:2003, IEC61156-5:2002
Mechanical Characteristics
Minimalbendingradius Repeatedbending:7,5xdiameter Singlebending:3xdiameter
Tensilestrength max.150N
Electrical Characteristics at 20 °C
Transfer impedance 10 MHz 10 mOhm/m
Conductorresistance max.115Ohm/km
Insulationresistance min.500MOhm*km
Velocity of propagation 5.3 ns/m
Characteristic impedance at 100 MHz 100 Ohm ± 5 Ohm
Test voltage (wire/wire/screenrms50Hz1min) 2000V
Chemical Characteristics
Flameretardant IEC60332-1-2
Freeofhazardoussubstances RoHS2002/95/EG
Limitedoilresistance
Sunlightresistant UL1581Sec.1200
Thermal Characteristics
Permissible temperature range
fixedoperation –40°Cto+75°C
flexibleoperation –20°Cto+60°C
Printing HARTINGINDUSTRIALETHERNETSTANDARDCABLECAT5PLUS*22AWG(SHIELDED)(UL)E333432VERI-FIEDCAT5ECMG75°CorPLTCorAWM21694600VFT4SUNRES*094560001000100"Metermarkierung"*"Jahr/Auftragsnummer""HARTING-LOGO"
Weight about 66kg/km
09 4
5 60
0 01
X0 Technical Characteristics
HARTING PROFINET Type A Cable 4-wire Cat. 5 PVC
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
*EN50288-2-1:2003
FrequencyMHz
AttenuationdB/100m
NEXTdB
typ. Cat 5 max* typ. Cat 5
min*
1 1.6 2.1 80 65.3
4 3.2 4.0 75 56.3
10 5.2 6.3 70 50.3
16 6.9 8.0 65 47.2
20 7.8 9.0 63 45.8
31.25 10.5 11.4 60 42.9
62.5 15 16.5 55 38.4
100 19.5 21.3 50 35.3
09 45 600 013209 45 600 014209 45 600 010209 45 600 0112
09 4
5 60
0 01
X2
HARTING PROFINET Type B Cable 4-wire Cat. 5 PVC
Advantages General
Identification Part number Drawing
• SuitableforPROFINETcablingCategory5/ClassDaccordingtoISO/IEC11801respectivelyEN50173-1andISO/IEC24702respectively EN 50 173-3
• Capableflexiblecords
• Applicableforindustrialpremises
• RoHSconform,ULlisted,flameretardant
This data cable is suitable for PROFINET cabling according to type B in industrial premises and ar-eas. It is useable for flexible cords. The core isfitted with 4 wires twisted to quad that allows the transmission of Fast Ethernet 10/100Mbit/s.
It is designed for fast assembling with the easy-stripping tool and can be assembled with all HARTING 4-pole RJ45 connectors.
PROFINET Type B Cable4-wire,Cat.5,PVC
PROFINET Type B Cable4-wire,Cat.5,PVC
20 m ring 50 m ring 100 m ring 500 m reel
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
• Wire:StrandedtinnedcopperAWG22/7• Insulation::PEØ1.56mm(±0.03)• Innersheath:Polyvinylchloride(PVC)• Overallscreen:aluminatefoiloverlapped,tinned
copperwirebraid,braidcoverageabout85%• Outersheath:Polyvinylchloride(PVC),flame
retardantColorcode:wh,ye,bu,orColorofinnersheath:whiteColorofoutersheath:green,RAL6018Overalldiameter:6.3mm–6.7mm
09 4
5 60
0 01
X2
Technical Characteristics
HARTING PROFINET Type B Cable 4-wire Cat. 5 PVC
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
Performance Category5accordingtoEN50288-2-1:2003, IEC61156-5:2002
Mechanical Characteristics
Minimalbendingradius Repeatedbending:5xdiameter Singlebending:3xdiameter
Torsionalstrength ±180°on1m,30,000cycles
Electrical Characteristics at 20 °C
Transfer impedance 10 MHz 20 mOhm/m
Conductorresistance max.120Ohm/km
Insulationresistance min.500MOhm*km
Velocity of propagation 5.3 ns/m
Characteristicimpedanceat100MHz 100Ohm±5Ohm
Test voltage (wire/wire/screenrms50Hz1min) 2000V
Chemical Characteristics
Flameretardant UL1685(CSAFT4)
Freeofhazardoussubstances RoHS2002/95/EG
Sunlightresistant UL1581Sec.1200
Thermal Characteristics
Permissible temperature range
fixedoperation –40°Cto+70°C
flexibleoperation –20°Cto+60°C
Printing HARTINGINDUSTRIALETHERNETSTRANDEDCABLECAT5PLUS*22AWG(SHIELDED)(UL)E333432CMGorPLTCorAWM2169580°C600VFT4SUNRES*094560001020200"Metermarkierung"*"Jahr/Auftragsnummer"HARTING-LOGO"
Weight about 68kg/km
09 4
5 60
0 01
X2
Technical Characteristics
HARTING PROFINET Type B Cable 4-wire Cat. 5 PVC
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
*EN50288-2-1:2003
FrequencyMHz
AttenuatindB/100m
NEXTdB
typ. Cat 5 max* typ. Cat 5
min*
1 2.1 2.1 80 80
4 4 4 76 76
10 6.3 6.3 70 70
16 8 8 65 65
20 9 9 63 63
31.25 11.4 11.4 60 60
62.5 16.5 16.5 55 55
100 21.3 21.3 50 50
l
09 45 600 013509 45 600 014509 45 600 010509 45 600 0115
09 4
5 60
0 01
X5
HARTING PROFINET Type B Outdoor Cable 4-wire Cat. 5 PVC
Advantages General
Identification Part number Drawing
• SuitableforPROFINETcablingCategory5/ClassDaccordingtoISO/IEC11801respectivelyEN50173-1andISO/IEC24702respectively EN 50 173-3
• Capableforoutdoorinstallation
• Applicableforindustrialpremises
• RoHSconform,ULlisted,flameretardant
This data cable is suitable for PROFINET cabling according to type B in industrial premises and ar-eas. It is useable for flexible cords. The core is fitted with 4 wires twisted to quad that allows the transmission of Fast Ethernet 10/100 Mbit/s.
It is designed for fast assembling with the easy-stripping tool and can be assembled with all HARTING 4-pole RJ45 connectors.
PROFINETTypeBOutdoorcable4-wire,Cat.5,PVC
PROFINET Type B Outdoor Cable4-wire,Cat.5,PVC
20m ring 50 m ring 100 m ring 500 m reel
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
• Wire:StrandedtinnedcopperAWG22/7• Insulation::PEØ1.56mm(±0.03)• Innersheath:Polyvinylchloride(PVC)• Overallscreen:aluminatefoiloverlapped,tinned
copperwirebraid,braidcoverageabout85%• Outersheath:Polyvinylchloride(PVC),
flame retardantColorcode:wh,ye,bu,orColorofinnersheath:whiteColorofoutersheath:black,RAL9005Overalldiameter:6.3mm–6.7mm
09 4
5 60
0 01
X5
Technical Characteristics
HARTING PROFINET Type B Outdoor Cable 4-wire Cat. 5 PVC
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
Performance Category5accordingtoEN50288-2-1:2003, IEC61156-5:2002
Mechanical Characteristics
Minimalbendingradius Repeatedbending:5xdiameter Singlebending:3xdiameter
Torsionalstrength ±180°on1m,30,000cycles
Electrical Characteristics at 20 °C
Transferimpedance10MHz 20mOhm/m
Conductorresistance max.120Ohm/km
Insulationresistance min.500MOhm*km
Velocity of propagation 5.3 ns/m
Characteristicimpedanceat100MHz 100Ohm±5Ohm
Test voltage (wire/wire/screenrms50Hz1min) 2000V
Chemical Characteristics
Flameretardant UL1685(CSAFT4)
Freeofhazardoussubstances RoHS2002/95/EG
Sunlightresistant UL1581Sec.1200
Thermal Characteristics
Permissible temperature range
fixedoperation –40°Cto+70°C
flexibleoperation –20°Cto+60°C
Printing HARTINGINDUSTRIALETHERNETSTRANDEDCABLECAT5PLUS*UVprotected*22AWG(SHIELDED)(UL)E333432CMGorPLTCorAWM2169580°C600VFT4SUNRES*094560001020300"Metermarkierung"*"Jahr/Auftragsnummer""HARTING-LOGO"
Weight about 68kg/km
09 4
5 60
0 01
X5
Technical Characteristics
HARTING PROFINET Type B Outdoor Cable 4-wire Cat. 5 PVC
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
*EN50288-2-1:2003
FrequencyMHz
AttenuatindB/100m
NEXTdB
typ. Cat 5 max* typ. Cat 5
min*
1 2.1 2.1 80 80
4 4 4 76 76
10 6.3 6.3 70 70
16 8 8 65 65
20 9 9 63 63
31.25 11.4 11.4 60 60
62.5 16.5 16.5 55 55
100 21.3 21.3 50 50
09 45 600 013909 45 600 014909 45 600 010909 45 600 0119
09 4
5 60
0 01
X9
HARTING PROFINET Type B Cable 4-wire Cat. 5 PUR
Advantages General
Identification Part number Drawing
• SuitableforPROFINETcablingCategory5/ClassDaccordingtoISO/IEC11801respectivelyEN50173-1andISO/IEC24702respectively EN 50 173-3
• Capableforflexiblecords
• Applicableforindustrialpremises
• RoHSconform,flameretardant,halogenfree
ThisdatacableissuitableforPROFINETcablingaccording to type B in industrial premises and ar-eas. It is useable for flexible cords. The core isfittedwith4wirestwistedtoquadthatallowsthetransmissionofFastEthernet10/100Mbit/s.
It isdesigned for fastassemblingwith theeasy-stripping tool and can be assembled with allHARTING 4-pole RJ45 connectors.
PROFINET Type B Cable4-wire,Cat.5,PUR
PROFINET Type B Cable4-wire,Cat.5,PUR
20m ring 50 m ring 100 m ring 500 m reel
Alldatagivenareinlinewiththeactualstateofartandthereforenotbinding. HARTINGreservestherighttomodifydesignswithoutgivingtherelevantreasons.
• Wire:StrandedtinnedcopperAWG22/7• Insulation::PEØ1.56mm(±0.03)• Innersheath:ThermoplasticCopolymer(FRNC)• Overallscreen:aluminatefoiloverlapped,tinned
copperwirebraid,braidcoverageabout85%• Outersheath:Polyurethane(PUR),flame
retardant,halogenfreeColorcode:wh,ye,bu,orColorofinnersheath:whiteColorofoutersheath:green,RAL6018Overalldiameter:6.3mm–6.7mm
09 4
5 60
0 01
X9
TechnicalCharacteristics
HARTING PROFINET Type B Cable 4-wire Cat. 5 PUR
Alldatagivenareinlinewiththeactualstateofartandthereforenotbinding. HARTINGreservestherighttomodifydesignswithoutgivingtherelevantreasons.
Performance Category5accordingtoEN50288-2-1:2003, IEC61156-5:2002
Mechanical Characteristics
Minimalbendingradius Repeatedbending:7xdiameter Singlebending:3xdiameter
Torsionalstrength ±180°on1m,30,000cycles
Electrical Characteristics at 20 °C
Transferimpedance10MHz 20mOhm/m
Conductorresistance max.120Ohm/km
Insulationresistance min.500MOhm*km
Velocity of propagation 5.3 ns/m
Characteristicimpedanceat100MHz 100Ohm±5Ohm
Test voltage (wire/wire/screenrms50Hz1min) 2000V
Chemical Characteristics
Flameretardant IEC60332-1-2
Freeofhazardoussubstances RoHS2002/95/EG
Thermal Characteristics
Permissible temperature range
fixedoperation –40°Cto+70°C
flexibleoperation –20°Cto+60°C
Printing HARTINGINDUSTRIALETHERNETSTRANDEDCABLECAT5PLUSPURFRNC*22AWG(SHIELDED)*094560001020400"sequentiallengthinmeters"*"year/in-ternalordernumber"HARTINGLOGO"
Weight about 62kg/km
09 4
5 60
0 01
X9
TechnicalCharacteristics
HARTING PROFINET Type B Cable 4-wire Cat. 5 PUR
Alldatagivenareinlinewiththeactualstateofartandthereforenotbinding. HARTINGreservestherighttomodifydesignswithoutgivingtherelevantreasons.
*EN50288-2-1:2003
FrequencyMHz
AttenuatindB/100m
NEXTdB
typ. Cat 5 max* typ. Cat 5
min*
1 2.1 2.1 80 80
4 4 4 76 76
10 6.3 6.3 70 70
16 8 8 65 65
20 9 9 63 63
31.25 11.4 11.4 60 60
62.5 16.5 16.5 55 55
100 21.3 21.3 50 50
l
09 45 600 013109 45 600 014109 45 600 010109 45 600 0111
09 4
5 60
0 01
X1
HARTING PROFINET Type C Cable 4-wire Cat. 5 PUR
Advantages General
Identification Part number Drawing
• SuitableforPROFINETcablingCategory5/ClassDaccordingtoISO/IEC11801respectivelyEN50173-1andISO/IEC24702respectively EN 50 173-3
• Capablefordrag-line
• Applicableforindustrialpremises
• RoHSconform,ULlisted,flameretardant,halogen free
This data cable is suitable for PROFINET cabling according to type C in industrial premises and ar-eas. It is useable for flexible cords especially for drag-chain. The core is fitted with 4 wires twisted to quad that allows the transmission of Fast Ether-net 10/100 Mbit/s.
It is designed for fast assembling with the easy-stripping tool and can be assembled with all HARTING 4-pole RJ45 connectors.
PROFINET Type C Cable4-wire,Cat.5,PUR
PROFINET Type C Cable4-wire,Cat.5,PUR
20m ring 50 m ring 100 m ring 500 m reel
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
• Wire:StrandedtinnedcopperAWG22/7• Insulation::PEØ1.56mm(±0.03)• Innersheath:Thermoplasticcopolymer(FRNC)• Overallscreen:aluminatefoiloverlapped,tinned
copperwirebraid,braidcoverageabout85%• Outersheath:Polyurethane(PUR),
flame retardantColorcode:wh,ye,bu,orColorofinnersheath:whiteColorofoutersheath:green,RAL6018Overalldiameter:6.3mm–6.7mm
09 4
5 60
0 01
X1
Technical Characteristics
HARTING PROFINET Type C Cable 4-wire Cat. 5 PUR
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
Performance Category5accordingtoEN50288-2-1:2003, IEC61156-5:2002
Mechanical CharacteristicsMinimalbendingradius Repeatedbending:7xdiameter Singlebending:3xdiameterTensile strength max. 150 NTrailing strength 3 million bending cycles
bendingdiameter200mm at a speed of 4 m/s acceleration 4 m/s²
Torsionalstrength ±180°on1m,30,000cycles
Electrical Characteristics at 20 °C Transferimpedance10MHz 20mOhm/mConductorresistance max.120Ohm/kmInsulationresistance min.500MOhm*kmVelocity of propagation 5.3 ns/mCharacteristicimpedanceat100MHz 100Ohm±5OhmTest voltage (wire/wire/screenrms50Hz1min) 2000V
Chemical CharacteristicsFlameretardant IEC60332-1-2Freeofhazardoussubstances RoHS2002/95/EGOilresistance EN60811-2-1UV-resistant
Thermal CharacteristicsPermissible temperature range fixedoperation –40°Cto+70°C flexibleoperation –20°Cto+60°C
Printing HARTINGINDUSTRIALETHERNETTRAILINGCABLECAT5PLUS* E333432VERIFIED(UL)CAT5EPATCHCABLECMX75°CFRNC*2x2xAWG22/7*094560001010100"Metermarkierung"*"HARTING-LOGO"
Weight about 61kg/km
09 4
5 60
0 01
X1
Technical Characteristics
HARTING PROFINET Type C Cable 4-wire Cat. 5 PUR
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
*EN50288-2-1:2003
FrequencyMHz
AttenuatindB/100m
NEXTdB
typ. Cat 5 max* typ. Cat 5
min*
1 2.1 2.1 80 65.3
4 4 4 76 56.3
10 6.3 6.3 70 50.3
16 8 8 65 47.2
20 9 9 63 45.8
31.25 11.4 11.4 60 42.9
62.5 16.5 16.5 55 38.4
100 21.3 21.3 50 35.3
l
09 45 600 111009 45 600 112009 45 600 113009 45 600 1140
09 4
5 60
0 11
X0
HARTING PROFINET Type C Torsional Stress Cable 4-wire, Cat. 5, PUR
Advantages General
Identification Part number Drawing
• SuitableforPROFINETcablingCategory5/ ClassDaccordingtoISO/IEC11801respectivelyEN50173andISO/IEC24702respectively EN 50 173-3
• Applicableforindustrialpremises
• Applicablefortorsionalstress
• RoHSconform,ULrecognized, flame retardant, halogen free
This data cable is suitable for PROFINET cabling according to type C torsional stress in industrial premises and areas. It is usable for flexible cords especially e.g. for industrial robot application. The core is fitted with 4 wires twisted to quad that allows the transmission of Fast Ethernet 10/100Mbit/s.
Can be assembled with all HARTING 4-pole RJ45 connectors.
PROFINET Type C Torsional Cable 4-wire, Cat. 5, PUR
PROFINET Type C Torsional Cable 4-wire, Cat. 5, PUR
20 m ring 50 m ring 100 m reel 500 m reel
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
• Wire:StrandedtinnedcopperAWG22/19
• Foamed:PEØ1.52mm(±0.03)
• PlasticTape,overlapped
• Overallscreen:tinnedcopperwirebraid, braidcoverageabout85%
• Outersheath:Polyurethane(PUR), flame retardant
Colorcode:wh,ye,bu,or
Colorofoutersheath:green,RAL6018
Overalldiameter:6.3mm–6.7mm
09 4
5 60
0 11
X0
Technical Characteristics
HARTING PROFINET Type C Torsional Stress Cable 4-wire, Cat. 5, PUR
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
Performance Category5accordingtoEN50288-2-2:2003, IEC61156-6:2002
Mechanical Characteristics
Minimalbendingradius Singlebending:5xdiameter max. 150 N
Torsionalstrength ±180°on1m,1Mil.cycles
Electrical Characteristics at 20 °C
Conductorresistance max.120Ohm/km
Insulationresistance min.500MOhm*km
Velocityofpropagation 4.7ns/m
Characteristicimpedanceat100MHz 100Ohm±15Ohm
Test voltage (wire/wire/screenrms50Hz1min) 700V
Chemical Characteristics
Halogen free
Flame retardant IEC 60 332-1-2 UL-Style21161(80°C)
Thermal Characteristics
Permissibletemperaturerange –40°Cto+80°C
Printing HARTINGINDUSTRIALETHERNETTORSIONALSTRESSCABLECAT5PLUS*22AWG*E333435 AWMSTYLE2116180°C*094560001010300„sequentiallengthinmeters“*„year/internalordernumber“„HARTINGLOGO“
Weight about 54kg/km
09 4
5 60
0 11
X0
Technical Characteristics, Transmission performance
HARTING PROFINET Type C Torsional Stress Cable 4-wire, Cat. 5, PUR
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
l
09 45 600 031009 45 600 033009 45 600 034009 45 600 030009 45 600 0320
09 4
5 60
0 03
X0
HARTING PROFINET Hybrid Cable 4-wire + 4 x 1.5 Cat. 5 FRNC
Advantages General
Identification Part number Drawing
• SuitableforPROFINETcablingCategory5/ClassDaccordingtoISO/IEC11801respectivelyEN50173-1andISO/IEC24702respectively EN 50 173-3
• Capableforflexiblecords
• Applicableforindustrialpremises
• RoHSconform,ULrecognized,flame retardant FRNC
This data cable is suitable for PROFINET Hybrid cabling according to type B in industrial premises and areas. It is useable for flexible cords and in-stallation also. The core is fitted with 4 data wires twisted to star quad that allows the transmission of Fast Ethernet 10/100 Mbit/s and 4 power wires each of 1.5 mm² cross section.
It is designed for fast assembling in benefit for the customer. The PROFINET Hybrid cable is best ca-pable for termination with Han® 3 A RJ45 Hybrid connector set.
PROFINET Hybrid Cable 4-wire+4x1.5,Cat.5,FRNC
PROFINET Hybrid Cable4-wire+4x1.5,Cat.5,FRNC
10 m ring 20 m ring 50 m ring 100 m reel 500 m reel
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
Quad• Wire:StrandedtinnedcopperAWG22/7• Insulation:PEØ1.55mm• Color:wh,ye,bu,og• Screen:Aluminatefoiloverlapped,tinned
copperwirebraid,braidcoverageabout85%
Power• Wire:Strandedbarecopper4x1.5mm²
84x0.15mm(AWG16)• Insulation:FRNCØ2.4mm• Color:bk,numberprinted
Core• Plastictapeoverlapped• Outersheath:ThermoplasticCopolymer
(FRNC),flameretardant
Colorofoutersheath:green,RAL6018Overalldiameter:9.7mm–10.3mm
09 4
5 60
0 03
X0
Technical Characteristics
HARTING PROFINET Hybrid Cable 4-wire + 4 x 1.5 Cat. 5 FRNC
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
Performance Category5accordingtoEN50288-2-1:2003, IEC61156-5:2002
Mechanical CharacteristicsMinimalbendingradius Repeatedbending:10xdiameter Singlebending:5xdiameterTensile strength max. 200 N
Electrical Characteristics at 20 °C QuadTransferimpedanceat1MHz 50mOhm/mTransferimpedanceat10-100MHz 10mOhm/mConductorresistance max.120Ohm/kmInsulationresistance min.500MOhmxkmVelocity of propagation 5.3 ns/mCharacteristicimpedanceat100MHz 100Ohm±5OhmTest voltage (wire/wire/screenrms50Hz1min) 1500VOperating voltage 150 V
PowerConductorresistance max.14Ohm/kmInsulationresistance min.20MOhm*kmTest voltage (wire/wire/screenrms50Hz1min) 1500VOperating voltage 150 V
Chemical CharacteristicsFlame retardant IEC 60 332-1-2Freeofhazardoussubstances RoHS2002/95/EGHalogenfree EN60811-2-1
Thermal CharacteristicsPermissible temperature range fixedoperation –20°Cto+80°C flexibleoperation –20°Cto+80°C
Printing HARTINGPROFINETHYBRIDCABLECAT5FRNC* 4xAWG22/7+4x1.5(SHIELDED)E333435 AWM21282*09456000300200“internallotnumber”“sequentiallengthinmeters”
Weight about 154kg/km
09 4
5 60
0 03
X0
Technical Characteristics
HARTING PROFINET Hybrid Cable 4-wire + 4 x 1.5 Cat. 5 FRNC
All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons.
*EN50288-2-1:2003
FrequencyMHz
AttenuationdB/100 m
NEXTdB
PS NEXTdB
EL FEXTdB
PS EL FEXTdB
Return LossdB
typ. Cat 5 max* typ. Cat 5
min* typ. Cat 5 min* typ. Cat 5
min* typ. Cat 5 min* typ. Cat 5
min*
1 2.1 2.1 65.3 65.3 62.3 62.3 63.8 63.8 60.8 60.8 - -
4 4 4 56.3 56.3 53.3 53.3 51.8 51.8 48.8 48.8 23.0 23
10 6.3 6.3 50.3 50.3 47.3 47.3 43.8 43.8 40.8 40.8 25 25
16 8 8 47.2 47.2 44.2 44.2 39.7 39.7 36.7 36.7 25 25
20 9 9 45.8 45.8 42.8 42.8 37.8 37.8 34.8 34.8 25 25
31.25 11.4 11.4 42.9 42.9 39.9 39.9 33.9 33.9 30.9 30.9 23.6 23.6
62.5 16.5 16.5 38.4 38.4 35.4 35.4 27.9 27.9 24.9 24.9 21.5 21.5
100 21.3 21.3 35.3 35.3 32.3 32.3 23.8 23.8 20.8 20.8 20.1 20.1
l
09 45 600 033209 45 600 034209 45 600 0302
09 4
5 60
0 03
X2
HARTING Hybrid Cable 8-wire + 4 x 1.5 Cat. 6 PUR
Advantages General
Identification Part number Drawing
• SuitableforcablingCategory6/ClassEaccordingtoISO/IEC11801respectively EN50173-1andISO/IEC24702respectivelyEN50173-3
• ValidforGigabitEthernet1000Base-T acc.toIEEE802.3
• Capableforindustrialcommunicationscablingfortheoutdoor
• VeryrobustandhighflexiblePURjacket
• Halogen-freeandOilretardant
• GoodEMCcharacteristics
This data cable is suitable for Hybrid cabling inindustrialpremisesaswellasoutdoorareas.
The four twisted pairs PIMF construction isdesigned for Gigabit Ethernet and gives goodEMCcapabilities.
Thecablecomeswithfourpowerwireswhicheachofthemhasa1.5mm²crosssection.Polyurethaneis used for the cable sheath which protects thecableagainstingressandimpact.
HARTING offers field assembling Han® 3 A RJ45 Hybrid connectors with reliable IDC terminationtechnology.
The connectors are designed for fast and easyassemblingwithoutanyspecialtooling.
Hybrid Cable 8-wire + 4 x 1.5 Cat. 6 PUR
Hybrid Cable 8-wire + 4 x 1.5, Cat. 6, PUR
20 m ring 50 m ring 100 m reel
otherlengthonrequest
Alldatagivenareinlinewiththeactualstateofartandthereforenotbinding. HARTINGreservestherighttomodifydesignswithoutgivingtherelevantreasons.
Data wires• Wire:Strandedtinnedcopper
AWG28/7• Insulation:foamedPEØ0.98mm• Wires:TwistedPairacc.TIA/EIA568• Shielding:F/FTP,tinnedcopperwirebraid
coverage about 60 %
Power wires• Wire:Strandedbarecopper4x1.5mm²
84x0.15mm(AWG16)• Insulation:FRNCØ2.4mm• Color:bk,numberprinted
Core• Plastictapeoverlapped• Outersheath:Polyurethane,flameretardant
andhalogenfree
Colorofoutersheath:black,RAL9004Overalldiameter:10.0mm–10.6mm
09 4
5 60
0 03
X2
TechnicalCharacteristics
HARTING Hybrid Cable 8-wire + 4 x 1.5 Cat. 6 PUR
Alldatagivenareinlinewiththeactualstateofartandthereforenotbinding. HARTINGreservestherighttomodifydesignswithoutgivingtherelevantreasons.
Performance Category6accordingtoEN50288-5-2,IEC61156-5 Note:Standardizedupto60m.Forlengthaboveattenuationismax.10%higher.
Mechanical CharacteristicsMinimalbendingradius Repeatedbending:10xdiameter Singlebending:5xdiameterTensilestrength max.200N
Electrical Characteristics at 20 °C Data wiresConductorresistance 385Ohm/kmInsulationresistance 1.5TOhmxkmVelocityofpropagation 4.6ns/mCharacteristicimpedanceat100MHz 105Ohm±5OhmTest voltage (wire/wire/screenrms50Hz1min) 700VOperatingvoltage 100V
PowerConductorresistance max.14Ohm/kmInsulationresistance min.20MOhm*kmTest voltage (wire/wire/screenrms50Hz1min) 1500VOperatingvoltage 150V
Chemical CharacteristicsFlameretardant ULstyle21523(80°C/30V)Freeofhazardoussubstances RoHS2002/95/EGHalogen freeOilresistant EN60811-2-1UVresistant
Thermal CharacteristicsPermissibletemperaturerange fixedoperation –20°Cto+80°C flexibleoperation –20°Cto+80°C
Printing HARTINGHYBRIDEthernetOUTDOORCABLECAT6PUR4x2xAWG28/7+4x1.5094560007000000*E333435
AWM2152380°C30V*"sequentiallengthinmeters""internallotnumber""HARTING-Logo"
Weight about 135kg/km
09 4
5 60
0 03
X2
TechnicalCharacteristics
HARTING Hybrid Cable 8-wire + 4 x 1.5 Cat. 6 PUR
Alldatagivenareinlinewiththeactualstateofartandthereforenotbinding. HARTINGreservestherighttomodifydesignswithoutgivingtherelevantreasons.
FrequencyMHz
AttenuationdB/100 m
NEXTdB
PS NEXTdB
EL FEXTdB
PS EL FEXTdB
Return LossdB
typ. Cat 6 max* typ. Cat 6
min* typ. Cat 6 min* typ. Cat 6
min* typ. Cat 6 min* typ. Cat 6
min*
1 3 3.1 75 66 75 64 80 66 80 64 24 20
4 5.6 5.8 80 65.3 80 63.3 80 58 80 55 27 23
10 8.7 9.0 95 59.3 90 57.3 75 50 70 47 29 25
16 11 11.4 95 56.2 90 54.2 70 45.9 68 43 29 25
20 12.2 12.8 91 54.8 88 52.8 68 44 65 41 29 25
31,25 15.3 16.1 88 51.9 86 49.9 62 40.1 62 37.1 30 23.6
62,5 22 23.2 83 47.4 78 45.3 45 34.1 45 31.1 30 21.53
100 28.3 29.9 77 44.3 75 42.3 38 30 40 27 30 20.1
155 36 38.0 72 41.4 70 39.4 38 26.2 38 23.2 26 18.8
200 41.5 43.7 68 39.8 67 37.8 37 24 37 21 23 18
250 47.1 49.5 65 38.3 65 36.3 35 22 35 19 22 17.32
*EN50288-2-1:2003
Identification Partnumber
HARTINGTools
TheRJIndustrialStrippingToolisreadytoremoveinsulationfromcablesforfastmountingwithdiametersfrom2.5to8mmquickandeasy. Itallows to removecablesheathandshieldingbraidinone.
HARTINGRJIndustrial®StrippingToolStrippingtoolforEthernetcablesincludingbladecassette 09458000000
Sparebladecassette 09458000001