hardware engineering data sheet - primacoustic

4
ENGINEERING DATA SHEET Primacoustic is a division of Radial Engineering Ltd. • 1588 Kebet Way Port Coquitlam, BC V3C 5M5 • Tel: 604-942-1001 Fax: 604-942-1010 www.primacoustic.com • [email protected] • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice. Push-On Impaler: Surface Impaler: Surface Impalers™ are designed to provide the installer with a simple, quick, and effective method of mounting Broadway™ glass wool panels onto walls without causing serious surface defacement. Primacoustic Surface Impalers allow the installer to simply pull the panel down onto the Impaler clip quickly and efficiently, while allowing for some levelling adjustability after the panel is installed. The Surface Impaler features four sharp darts that penetrate the panel and secure it in place. To ensure panels do not get dislodged after installation, applying a dab of construction adhesive to the center of the Impaler during the mounting process adds a level of security and reduces opportunity for tampering. Impalers are installed using typical sheetrock anchors and screws. SURFACE IMPALER ORDER NUMBER Push-On: F101-1003-00 Surface: F101-1000-00 MATERIAL 20 gauge galvanized steel DIMENSIONS 3” (76mm) x 4” (102mm) ATTACHMENT POINTS 2 (Use appropriate fastener for wall surface) MAX LOAD LIMIT 12 lbs. (5.4 kg.) Dependant on wall fastener NUMBER PER BOX 24 per box SPECIFICATIONS: 3” (77mm) 4” (102mm) Push-on Impalers™ are designed to provide the installer with a simple, quick and effective method of mounting Broadway™ glass wool panels onto walls without causing serious surface defacement. Primacoustic Push-On Impalers allow the installer to push the Broadway panel straight onto the Impaler clip, making it easier to align panels in clusters or side by side with accuracy. The Push-On Impaler features a series of sharp protruding darts that penetrate the panel and secure it in place. To ensure panels do not get dislodged after installation, applying a dab of construction adhesive to the center of the Impaler during the mounting process adds a level of security and reduces opportunity for tampering. Impalers are installed using typical sheetrock anchors and screws. PUSH-ON IMPALER 3” (77mm) 4” (102mm) Order No. Description HEIGHT WIDTH DEPTH No. of Impalers Needed* F121-1212-xx Scatter Blocks 12” (305mm) 12” (305mm) 1” (25mm) 1 F102-2424-xx Control Cubes 24” (610mm) 24” (610mm) 2” (51mm) 2 F122-2424-xx Control Cubes 24” (610mm) 24” (610mm) 2” (51mm) 2 F121-1248-xx Control Columns 12” (305mm) 48” (1219mm) 1” (25mm) 2 F122-1248-xx Control Columns 12” (305mm) 48” (1219mm) 2” (51mm) 2 F123-1248-xx Control Columns 12” (305mm) 48” (1219mm) 3” (76mm) 2 F121-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 1” (25mm) 4 F102-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 2” (51mm) 4 F122-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 2” (51mm) 4 F103-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 5 F123-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 5 F103-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 5 F123-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 5 RECOMMENDED MINIMUM NUMBER OF IMPALERS PER PANEL:* *Primacoustic recommends a certain number of impalers per panel as the minimum required for safe installation based on panel depth and weight. For additional security, you may wish to increase these numbers per panel and also combine with construction adhesive. 12” x 12” 24” x 24” 12” x 48” 24” x 48” 4” (102mm) 4” (102mm) Flush mount impaler clips should be located approximately 4 inches (102mm) or more from the panel edges.

Upload: others

Post on 07-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

ENGINEERING DATA SHEET

P r i m a c o u s t i c i s a d i v i s i o n o f R a d i a l E n g i n e e r i n g L t d . • 1 5 8 8 K e b e t Wa y P o r t C o q u i t l a m , B C V 3 C 5 M 5 • Te l : 6 0 4 - 9 4 2 - 1 0 0 1 F a x : 6 0 4 - 9 4 2 - 1 0 1 0www.primacoustic.com • [email protected] • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice.

Push-On Impaler:

Surface Impaler:

Surface Impalers™ are designed to provide the installer with a simple, quick, and effective method of mounting Broadway™ glass wool panels onto walls without causing serious surface defacement. Primacoustic Surface Impalers allow the installer to simply pull the panel down onto the Impaler clip quickly and efficiently, while allowing for some levelling adjustability after the panel is installed.

The Surface Impaler features four sharp darts that penetrate the panel and secure it in place. To ensure panels do not get dislodged after installation, applying a dab of construction adhesive to the center of the Impaler during the mounting process adds a level of security and reduces opportunity for tampering. Impalers are installed using typical sheetrock anchors and screws.

suRFAce iMPAleR

ORDER NUMBER Push-On: F101-1003-00 Surface: F101-1000-00

MATERIAL 20 gauge galvanized steel

DIMENSIONS 3” (76mm) x 4” (102mm)

ATTACHMENT POINTS 2 (Use appropriate fastener for wall surface)

MAX LOAD LIMIT 12 lbs. (5.4 kg.) Dependant on wall fastener

NUMBER PER BOX 24 per box

SPECIFICATIONS:

3” (77mm)

4” (102mm

)

Push-on Impalers™ are designed to provide the installer with a simple, quick and effective method of mounting Broadway™ glass wool panels onto walls without causing serious surface defacement. Primacoustic Push-On Impalers allow the installer to push the Broadway panel straight onto the Impaler clip, making it easier to align panels in clusters or side by side with accuracy.

The Push-On Impaler features a series of sharp protruding darts that penetrate the panel and secure it in place. To ensure panels do not get dislodged after installation, applying a dab of construction adhesive to the center of the Impaler during the mounting process adds a level of security and reduces opportunity for tampering. Impalers are installed using typical sheetrock anchors and screws.

PusH-On iMPAleR 3” (77mm)

4” (102mm

)

Order No. Description HEIGHT WIDTH DEPTH No. of

Impalers Needed*

F121-1212-xx Scatter Blocks 12” (305mm) 12” (305mm) 1” (25mm) 1F102-2424-xx Control Cubes 24” (610mm) 24” (610mm) 2” (51mm) 2F122-2424-xx Control Cubes 24” (610mm) 24” (610mm) 2” (51mm) 2F121-1248-xx Control Columns 12” (305mm) 48” (1219mm) 1” (25mm) 2F122-1248-xx Control Columns 12” (305mm) 48” (1219mm) 2” (51mm) 2F123-1248-xx Control Columns 12” (305mm) 48” (1219mm) 3” (76mm) 2F121-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 1” (25mm) 4F102-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 2” (51mm) 4F122-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 2” (51mm) 4F103-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 5F123-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 5F103-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 5F123-2448-xx Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 5

RECOMMENDED MINIMUM NUMBER OF IMPALERS PER PANEL:*

*Primacoustic recommends a certain number of impalers per panel as the minimum required for safe installation based on panel depth and weight. For additional security, you may wish to increase these numbers per panel and also combine with construction adhesive.

12” x 12” 24” x 24” 12” x 48” 24” x 48”

4” (102mm)

4” (102mm

) Flush mount impaler clips should be located approximately 4 inches (102mm) or more from the panel edges.

ENGINEERING DATA SHEET

P r i m a c o u s t i c i s a d i v i s i o n o f R a d i a l E n g i n e e r i n g L t d . • 1 5 8 8 K e b e t Wa y P o r t C o q u i t l a m , B C V 3 C 5 M 5 • Te l : 6 0 4 - 9 4 2 - 1 0 0 1 F a x : 6 0 4 - 9 4 2 - 1 0 1 0www.primacoustic.com • [email protected] • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice.

5” (127mm

)

3” (77mm)

2” (51mm)

3.5” (89mm)Offset Impalers™ provide the installer with a simple, quick and effective

method of mounting Broadway™ glass wool acoustic panels onto wall surfaces while creating an air cavity behind the panel to increase bass absorption.

The Offset Impaler features a U-shaped design that holds the panel from the wall surface by 3.5” making it easy to align with typical 2” x 4” studs. The panel is held in place using a series of sharp protruding darts that penetrate the panel to secure it during installation.

To ensure panels do not get dislodged after installation, applying a dab of construction adhesive to the impaler darts during the mounting process adds a level of security and reduces opportunity for tampering. Impalers are installed using typical sheetrock anchors and screws and therefore, will not cause serious surface defacement to the wall.

OFFset iMPAleR

Three inch Broadway panels with and without a 3.5” air space.

100H

z

125H

z

160H

z

200H

z

250H

z

315H

z

400H

z

500H

z

630H

z

800H

z

1kH

z

1.25

kHz

1.6k

Hz

2kH

z

2.5k

Hz

3.15

kHz

4kH

z

5kH

z

50H

z

150H

z

200H

z

250H

z

300H

z

350H

z

400H

z

450H

z

500H

z

550H

z

600H

z

700H

z

800H

z

900H

z

1.0k

Hz

2.0k

Hz

3.0k

Hz

4.0k

Hz

1.3

1.2

1.1

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

1.3

1.2

1.1

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

FREQUENCY (Hz) FREQUENCY (Hz)

SOU

ND

AB

SOR

PTIO

N C

OEF

FIC

IEN

T

SOU

ND

AB

SOR

PTIO

N C

OEF

FIC

IEN

T

3” Panel

3” Panelwith 3.5” offset

Two inch Broadway panels with Corner Impaler

Corner Impalers™ are designed to provide the installer with a simple, quick and effective method of mounting Broadway™ glass wool acoustic panels into corners to create bass traps. The Corner Impaler features a 45º angle design that positions a panel across a typical 90° corner without causing serious defacement of the wall surface.

The panel is held in place using a series of sharp protruding darts that penetrate the panel to secure it during installation. To ensure panels do not get dislodged after installation, a dab of construction adhesive may be applied to the impaler darts during the mounting process adding a higher level of security and reducing opportunity for tampering. Impalers are installed using typical sheetrock anchors and screws.

cORneR iMPAleR 3” (77mm)

5” (126mm

)

3” (77mm)

Order No. Description HEIGHT WIDTH DEPTH No. of

Impalers Needed

F102-2448-XX Broadband Panels 24” (610mm) 48” (1219mm) 2” (51mm) 4F122-2448-XX Broadband Panels 24” (610mm) 48” (1219mm) 2” (51mm) 4F103-2448-XX Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 4F123-2448-XX Broadband Panels 24” (610mm) 48” (1219mm) 3” (76mm) 4

RECOMMENDED NUMBER OF IMPALERS PER PANEL:

ORDER NUMBER Corner: F101-1001-00 Offset: F101-1002-00

MATERIAL 20 gauge galvanized steel

DIMENSIONS3” (76mm) x 5” (127mm) Corner = 45° angle for 90° corners.Offset = 3.5” (89mm) from wall surface

ATTACHMENT POINTS 4 (Use appropriate fastener for wall surface)

MAX LOAD LIMIT 12 lbs. (5.4 kg.) Dependant on wall fastener

NUMBER PER BOX 8 pieces

SPECIFICATIONS:

ENGINEERING DATA SHEET

P r i m a c o u s t i c i s a d i v i s i o n o f R a d i a l E n g i n e e r i n g L t d . • 1 5 8 8 K e b e t Wa y P o r t C o q u i t l a m , B C V 3 C 5 M 5 • Te l : 6 0 4 - 9 4 2 - 1 0 0 1 F a x : 6 0 4 - 9 4 2 - 1 0 1 0www.primacoustic.com • [email protected] • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice.

sliPnOt

cORKscReW

HeliX

Designed to suspend Primacoustic clouds and baffles, the SlipNot™ is a unique 76” (193cm) suspension cable system that combines aircraft steel rope with a cam-style releasable hook for easy height adjustment at one end and a simple eye-sling at the other. One merely attaches the sling to a suspension point and clips the hook onto the Primacoustic cloud or baffle using either the Corkscrew or Helix panel mounting screws.

Designed to create a vertical baffle using any Broadway or Paintables panel, the Corkscrew™ is a tensioned steel screw that twists into the edge of a panel for placement overhead. Combining the Corkscrew with the SlipNot enables the panel to be quickly adjusted to achieve a uniform height.

The Helix™ is a solid zinc die-cast device that integrates an eye hole and a wide screw that create a reliable and sturdy anchor for hanging any Primacoustic panel as an acoustic cloud using the adjustable SlipNot™ suspension system shown below.

ORDER NUMBER F101-1011-00

MATERIAL Steel

MAX LOAD LIMITS 45 lbs. (20.4 kg.) per anchor

NUMBER PER BOX 12 pieces

CABLE LENGHT 76” (193cm)

ORDER NUMBER F101-1004-00

MATERIAL Steel

MAX LOAD LIMITS 45 lbs. (20.4 kg.) per anchor

NUMBER PER BOX 12 pieces

ORDER NUMBER F101-1006-00

MATERIAL Plastic

MAX LOAD LIMITS 45 lbs. (20.4 kg.) per anchor

NUMBER PER BOX 12 pieces

SPECIFICATIONS:

SPECIFICATIONS:

SPECIFICATIONS:

ENGINEERING DATA SHEET

P r i m a c o u s t i c i s a d i v i s i o n o f R a d i a l E n g i n e e r i n g L t d . • 1 5 8 8 K e b e t Wa y P o r t C o q u i t l a m , B C V 3 C 5 M 5 • Te l : 6 0 4 - 9 4 2 - 1 0 0 1 F a x : 6 0 4 - 9 4 2 - 1 0 1 0www.primacoustic.com • [email protected] • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice.

2” Wall Mounted

2” Urethane Wall Mounted

2” Cloud Anchor Ceiling Mounted

clOuD AncHOR

snAP-On AncHOR

Suspending Broadway panels has never been easier or faster. Simply twist Cloud Anchors into the back of any 2” (5cm) or 3” (7.5cm) Broadway panel for a strong and secure installation.

The integrated eye-screw allows overhead suspension by tie-wire or chain. The Cloud Anchor is perfect for hanging Broadway acoustic panels in restaurants, call centers, boardrooms, schools and offices.

The Snap-On Anchor locks the panel onto any flat surface for installations where panels need to be mounted securely. Simply twist the anchor into the panel using the included tool and attach the corresponding locking pins to the wall or ceiling. The panel clicks and locks onto these pins, providing safe overhead/ceiling mounting and secure wall mounting in high traffic areas.

ORDER NUMBER F101-1007-00

MATERIAL Plastic and steel

MAX LOAD LIMITS 45 lbs. (20.4 kg.) per anchor

NUMBER PER BOX 12 pieces

ORDER NUMBER F101-1009-00

MATERIAL Plastic

MAX LOAD LIMITS 45 lbs. (20.4 kg.) per anchor

NUMBER PER BOX 50 pieces, tool, marking plugs

SPECIFICATIONS:

SPECIFICATIONS:

SOU

ND

AB

SOR

PTIO

N C

OEF

FIC

IEN

T

FREQUENCY (HZ)

Rotofast™

Rotofast™