Page 1 of 3
HARDBERGER PARK LAND BRIDGE
(RFCSP# TCI-031218MT)
AMENDMENT #3
April 2, 2018
Amendment #3 comprises of clarifications to the RFCSP and specifications
Specifications Revisions:
1. 01 5000 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS: Revise ‘PART 1 –
GENERAL’ to read:
1.2 SUMMARY
C. Support facilities…
1. “Field offices and storage sheds.”
Revise ‘PART 2- PRODUCTS’ to read:
2.2 EQUIPMENT
G. “Temporary Offices: Provide prefabricated or mobile units or similar job-built construction
with lockable entrances, operable windows, and serviceable finishes. Provide heated and air-
conditioned units on foundations adequate for normal loading.”
Revise ‘PART 3- EXECUTION’ to read:
3.2 TEMPORARY UTILITY INSTALLATION
E. “General: Engage the appropriate local utility company to install temporary service or
connect to existing service. Where company provides only part of the service, provide the
remainder with matching, compatible materials and equipment. Comply with company
recommendations.
1. Arrange with company and existing users for a time when service can be interrupted, if
necessary, to make connections for temporary services.
2. Provide adequate capacity at each stage of construction. Prior to temporary utility
availability, provide trucked-in services.
3. Obtain easements to bring temporary utilities to the site where the Owner's easements
cannot be used for that purpose.
4. Use Charges: Cost or use charges for temporary facilities are not chargeable to the Owner
or Owner’s Representative. Neither the Owner nor Owner’s Representative will accept
cost or use charges as a basis of claims for Change Orders.
F. Water Service: Install water service and distribution piping of sizes and pressures adequate
for construction until permanent water service is in use.
I. CLARIFICATION TO RFCSP AND SPECIFICATIONS
Page 2 of 3
1. Sterilization: Sterilize temporary water piping prior to use.
G. Temporary Electric Power Service: Provide weatherproof, grounded electric power service
and distribution system of sufficient size, capacity, and power characteristics during
construction period. Include meters, transformers, overload-protected disconnects, automatic
ground-fault interrupters, and main distribution switch gear.
1. Install electric power service underground, except where overhead service must be used.
2. Power Distribution System: Install wiring overhead and rise vertically where least
exposed to damage. Where permitted, wiring circuits not exceeding 125 Volts, ac 20
Ampere rating, and lighting circuits may be nonmetallic sheathed cable where overhead
and exposed for surveillance.
H. Temporary Lighting: Provide temporary lighting.
1. Install and operate temporary lighting that will fulfill security and protection
requirements without operating the entire system. Provide temporary lighting that will
provide adequate illumination for construction operations and traffic conditions.
3.3 SUPPORT FACILITIES INSTALLATION
F. “Locate field offices, storage sheds, and other temporary construction and support facilities
for easy access.
1. Maintain support facilities until near Substantial Completion, or until directed by the
Owner’s Representative.
G. Provide incombustible construction for offices, shops, and sheds located within the
construction area or within 30 feet (9 m) of building lines. Comply with requirements of
NFPA 241.
H. Field Offices: Where deemed necessary, provide insulated, weather-tight temporary offices of
sufficient size to accommodate required Transportation and Capital Improvements office
personnel at the Project Site. Keep the office clean and orderly for use for small progress
meetings. Furnish and equip offices as follows:
1. Furnish with a desk and chairs, a 4-drawer file cabinet, plan table, plan rack, and a 6-shelf
bookcase.
2. Equip with a water cooler and private toilet complete with water closet, lavatory, and
medicine cabinet unit with a mirror.
3. Furnish with a meeting table and chairs to accommodate at least (14) meeting attendees.”
Plan Revisions: (Changes are clouded on the attached sheets)
1. L300, L301, and L302 - Anti-Graffiti Coating Notes at the top of the page. Revise Note 1, third
sentence to read: “CSL Silicones, Inc. Si-Coat 530 AG or equal.”
2. L300, Detail 2. Revise location of limestone wall signage. See attached sheet, LSD- 3-2.
3. L304, Detail 1. Remove the detail reference for Infiltration Swale, Detail 11/L400.
4. L306, Detail 3. Add junction box, painted. Add note for conduit to be painted. Revise dimensions of
light fixture and weathering steel light fixture enclosure, including steel angle. Add reference to
manufacturer’s recommendations at light fixture assembly and note to separate dissimilar metals.
Page 3 of 3
Change power connection note to include typical fixture length. Remove note for DMX connection.
Add/Alt 8. See the attached sheet, LSD- 3-1.
5. L410, Detail 1: Show extent of light fixtures for Steel Wall Lighting in plan; indicate vertical conduit
locations. Add/Alt 8. See the attached sheet, L410.
6. L410, Detail 2: Add conduit and in-grade pull box for Steel Wall Lighting, Add/Alt 8. See the attached
sheet, L410.
7. L410, Detail 3: Add Steel Wall lighting enclosure at top of steel wall. Add detail reference to 3/L410.
Add painted conduit. Add/Alt 8. See the attached sheet, L410.
8. L410, Detail 4: Add Steel Wall lighting, enclosure, and conduit. Add/Alt 8. See the attached sheet,
L410.
9. L410, Detail 5: Revise steel angle connection from bolted to welding at steel wall. Show steel wall
stiffener and bracket in detail. See the attached sheet, L410.
10. L410, Detail 6: Revise note at intermediate bracket by travel restraint manufacturer. Revise channel
width and indicate channel length. Show steel wall stiffener and bracket in detail. See the attached
sheet, L410.
11. L411, Details 1 and 2. Add a typical note to read: “Refer to L300 and Details 1 and 2/L306 for steel
lighting cove at top of steel wall.”
12. L412, Details 1 and 2. Add a typical note to read: “Refer to L300 and Details 1 and 2/L306 for steel
lighting cove at top of steel wall.”
13. L450, Detail 7. Clarify that LED lights are centered in the body of letter. Add dimensions for the width
of the letter body, based on font. Add note for tamper-proof clip attachment. See the attached sheet,
LSD- 3-3.
14. L450, Reverse Channel Sign Letter Notes: Revise Note #3 to read: “Allow for a total of 25 letters
and/or characters at each of the (2) limestone wall signage locations….”
Revise Note #4 at add: “Power supply to fit in letter body. Extend module strand through conduit
from letter body with power supply to small characters, such as periods. Conceal conduit from
view.”
Revise Note #7 to add: “Approx. 4 watts/ft, subject to review through mockup.”
Add Note #10: “Contractor shall be responsible for obtaining any required sign permits and
paying any associated fees.”
15. E0003:
Item 1: Electrical lighting design on drawing now only incorporates in grade lighting
fixtures below bridge.
Item 2: All electrical lighting for Add Alternate #7 and #8 has been removed from the drawing. Delete
Keyed Notes 4 through 6.
16. New Sheet E0003A, Electrical Lighting Wall and Sign Plan:
Item 1: Electrical for backlit signage design is incorporated in the drawing, as Add Alternate #7.
Item 2: Electrical for Steel Wall lighting is incorporated in the drawing, as Add Alternate #8.
17. E0005:
Item 1: Electrical panel “H1” incorporates updated schedule indicating Add Alternate # 7 and # 8.
Item 2: Lighting fixture schedule incorporates updated fixture information for Add Alternates # 7 and
# 8.
Form 2 Unit Pricing Form:
Utilities and Irrigation Sections. Clarify that all Utilities, in ground Electrical conduit, in ground
Irrigation piping, and other Piping unit pricing shall include trenching, placement, and backfill, per unit
indicated.
No other items, dates, or deadlines for this RFCSP are changed.
END OF AMENDMENT 3
SD
SD
±100' ±83'±83'
2/L412 1/L412
R1500'-0"
R420'-0"
R420'-0"
R420'-0"
R420'-0"
R1500'-0"
5L410
5L410
32' NOM. LIGHTINGADD/ALT 8
32' NOM. LIGHTINGADD/ALT 8(2) 32' NOM. LIGHTING
ADD/ALT 8
32' NOM. LIGHTING
ADD/ALT 8
32' NOM. LIGHTINGADD/ALT 8
(2) 32' NOM. LIGHTINGADD/ALT 8
SD
SD
±100' ±83'±83'
1L306
2L306
1/L411 2/L411
2L410
1/L306
2/L3061L306
2L306
2L410
R420'-0"
R420'-0"
R1500'-0"
R1500'-0"
R420'-0"
R420'-0"
R1500'-0"
5L410 5
L410
32' NOM. LIGHTINGADD/ALT 8 32' NOM. LIGHTINGADD/ALT 8
(2) 32' NOM. LIGHTINGADD/ALT 8
32' NOM. LIGHTINGADD/ALT 8
32' NOM. LIGHTING
ADD/ALT 8
(2) 32' NOM. LIGHTINGADD/ALT 8
KS
DW
AS SHOWN
Steel WallDetails
L410
Sheet Title
Scale:
Issue Date
Project Number:
Drawn By
Checked By
Revisions
Sheet Number
Sheet of
2425 Broadway, Suite 105San Antonio, Texas 78215
p. 210.828.1155f. 210.828.1399
01.30.2018
1620
Sa
n A
nto
nio
, TX
PH
IL H
AR
DB
ER
GE
R P
AR
KLA
ND
BR
IDG
E
100
% C
ON
STRU
CTIO
N D
OC
UMEN
T SET
STEPHEN STIMSON ASSOCIATES
288 NORFOLK STREET CAMBRIDGE MA 02139
T 617 876 8960 F 617 876 8906
2 MOUNTAIN ROAD PRINCETON MA 01541
T 978 464 5200
WWW.STEPHENSTIMSON.COM
LANDSCAPE ARCHITECTS
HISTE C
CTTE
SA
ET
STA
IRE
G
2
OF
6 2
ETX
R
LDRE
CAANDS EP A
JAM
ESW. GRAY, JR.
Bid Set 03.02.2018
1" 6'-0"6'-0"
PANELPANEL
SCALE: 1"= 1'-0"
PLAN: STEEL WALL DETAIL
2
REF.
STRU
CTU
RAL
REF.
STRU
CTU
RAL
3/L402
4/L4
10
5L410
SCALE: 1"= 10'-0"
PLAN: STEEL WALLS A AND B
1
F.G.
6'-0" TYP.
REF.
PANE
L DET
AILS
, 8' M
IN.
4"
REF. STRUCTURAL
1"2"
REF. STRUCTURAL
SCALE: 1/2"= 1'-0"
PARK ELEVATION: STEEL WALL
3
REF.
STRU
CTU
RAL
1"
2/L410 OPP. HAND
5L410
4"
3/L3
06
NORTH
REF. STRUCTURAL
SCALE: 1/2"= 1'-0"
SECTION: STEEL WALL PANEL
4
4"±
REF.
STRU
CTU
RAL
REF.
STRU
CTU
RAL
5L410
SCALE: 2"= 1'-0"
DETAIL: TRAVEL RESTRAINT INTER.
6
3 1/
2"2
1/8"
4"
5 5/
8"
3" +/-
SCALE: 2"= 1'-0"
DETAIL: TRAVEL RESTRAINT END
5
5"
4"
3 1/2" 6"
5"
3"
3 Addendum 3 03.30.2018
3
3
3
3
3
3
3
3
3
3
3
3
1" M
IN.
4"
2 3/4"
2" +/-
SCALE: 6"= 1'-0"
DETAIL: STEEL WALL LIGHTING
3
RIALTO STUDIO, INC., 2425 Broadway Suite 105, San Antonio, Texas 78215, 210-828-1155 Fax 210-828-1399
Drawing No.
Scale
Title
DateRSI, Inc. Project No.
Project
Sheet Reference
Phil Hardberger Park Land Bridge
1620 March 30, 2018
Detail: Steel Wall Lighting
as notedLSD-3.1
L306
3
8L422
EXTENT OF COATING
3L306
TW 891.5
1-2L412
8L422
EXTENT OF COATING
8L450
SCALE: 1"= 10'-0"
WEST ELEVATION
2
3
RIALTO STUDIO, INC., 2425 Broadway Suite 105, San Antonio, Texas 78215, 210-828-1155 Fax 210-828-1399
Drawing No.
Scale
Title
DateRSI, Inc. Project No.
Project
Sheet Reference
Phil Hardberger Park Land Bridge
1620 March 30, 2018
West Elevation
as notedLSD-3.2
L300
3
RIALTO STUDIO, INC., 2425 Broadway Suite 105, San Antonio, Texas 78215, 210-828-1155 Fax 210-828-1399
Drawing No.
Scale
Title
DateRSI, Inc. Project No.
Project
Sheet Reference
Phil Hardberger Park Land Bridge
1620 March 30, 2018
Detail- Sign Lighting
3" = 1'-0"LSD-3.3
7/L450
EQ.EQ.
SCALE: 3"= 1'-0"
DETAIL: SIGN LIGHTING
7
3"
1'-6"
2 1/2" - 3" PER FONT
3
3
3