hanson buyer’s guide - prosense · hanson buyer’s guide march 2014. sales & support...
TRANSCRIPT
Hanson Buyer’s GuideMarch 2014
SaleS & Support
Corporate HeadquartersHanson Research Corporation9810 Variel AvenueChatsworth, CA 91311 USA
pHone 800.821.8165 or 818.882.7266Press 1 for Technical SupportPress 4 for Customer Support (Place & Track Orders)Press 5 for Sales Department (Request Quote or Literature)Press 6 for Service Department
Fax orders to 818.882.9470
online hansonresearch.comSales Support [email protected] Support [email protected] Support hansonresearch.com/tsrService Support (US) [email protected] Support (International) Contact your local Hanson representative
WarrantyHanson products are warranted for one full year, including parts and labor (except for glass and consumables). International dealer warranties may vary. A variety of HRCare service and preventive maintenance contracts are available to maintain peak operation of your Hanson equipment. Consult your Hanson representative for details.
Note: Minimum order $100.
Hanson Research is a certified ISO 9001:2008 corporation.
Table of Contents | 99-300-001 Rev. 3-14 | hansonresearch.com
table of ContentS
Sales & Support .................................................................Front Inside CoverVision® G2 Dissolution Test Instruments........................................................ 1
Vision® G2 Classic 6™ & Elite 8™ Dissolution Testers ...................................2Vision® G2 Classic 6™ & Elite 8™ Features ..................................................3Vision® G2 Classic 6™ & Elite 8™ Accessories .............................................4Vision® G2 Classic 6™ Dissolution Tester ....................................................5Vision® G2 Elite 8™ 1 L Dissolution Tester ...................................................7Vision® G2 Elite 8™ 2 L Dissolution Tester ...................................................9Vision® Dissolution Test Supplies & Accessories .......................................11Small Volume Dissolution Accessories .....................................................18Conversion & Upgrade Kits ......................................................................20Certificates & Service ...............................................................................20Design Qualification .................................................................................20 Tool Kits & Accessories ............................................................................21Vision® Spare Parts Kits ...........................................................................21 Q-Pak™ IQ/OQ/PQ Validation Guideline....................................................22
Vision® AutoPlus™ G2 Autosampling Systems ............................................ 23Vision® G2 AutoPlus™ Autosampler & AutoFill™ Collector .........................24Vision® G2 AutoPlus™ System Components .............................................25
Vision® AutoFilter Changer .......................................................................... 26Vision® AutoFilter™ Changer .....................................................................26
Dissolution Data Management Systems ..................................................... 27IDIS and ARGUS .....................................................................................27
On-Line HPLC Dissolution System ............................................................. 28SR8-Plus™ Dissolution Accessories ............................................................ 29Legacy AutoPlus™ Accessories .................................................................. 40Legacy Validation & Calibration Accessories ............................................... 42
Q-Pak™ IQ/OQ/PQ Validation Guideline....................................................42
Media-Mate Plus™ Automatic Prep System ................................................ 44Diffusion Cell Test Systems ......................................................................... 46
6-Cell Manual Test System.......................................................................46Vision® Microette™ Automated Test System ..............................................47Vision® Microette™ Single-Group vs. Multi-Group .....................................48Vertical Diffusion Cells ..............................................................................49
Physical Test Equipment ............................................................................. 53Flodex™ Powder Flowability Test Apparatus .............................................53Legacy QC-21™ Disintegration Test Supplies ...........................................53
HRCare™ .................................................................................................... 54Service & Validation Plans ........................................................................54ASTM Program ........................................................................................55Design Qualification .................................................................................55
Terms, Conditions, and Warranty ................................................................ 56Packaging Information ................................................................................ 57Trademarks ................................................................................................ 58Notices ....................................................................................................... 58Notes ......................................................................................................... 59About Hanson ....................................................................Back Inside Cover
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Testers1
Vision G2 Dissolution Testers
Vision G2 Dissolution
TestInstruments
Hanson Vision “G2” (second generation) dissolution instruments represent a significant upgrade from the original Vision testers introduced in 2008, as well as a brand new robust autosampling platform. Our new G2 operating platform combines rock-solid mechanics with a full-color touchscreen, intuitive instrument programming, up to 100 operating protocols, 21CFR11-compliant security, a convenient flash drive for instrument uploads and downloads, and 32-bit digital technology.
QUALITY | TECHNOLOGY | SCIENCEVision G2 dissolution test instruments are designed for the21st century, with state of the art electronics, mechanics and quality throughout. These systems are power-packed for the demands of today’s pharmaceutical scientist, from research, to formulations, to quality control and assurance. We’ve applied 60 years of innovation, expertise and know-how to the design and manufacture of these quality test systems.
THE ART OF DISSOLUTIONAt Hanson, we combine art with science and engineering. We apply elegant design and instrument ergonomics to the rigors and everyday challenges of scientific investigation, research and analysis. Every dissolution test operator requirement is evaluated and simplified for ease of use and fast results. Our test systems are designed for the dissolution laboratory with a tight schedule and a heavy workload.
OUR MISSION STATEMENTWe design and manufacture analytical test instrumentsfor the quality assurance of medicine, helping to promote better healthcare worldwide.
-Royal Hanson, Chairman
William A. Hanson, PhDHanson Research Founder & Dissolution Industry Pioneer
Royal Hanson
®
2 Vision Dissolution Testers | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Testers
Vision® G2 Dissolution Test Instruments
Vision G2 Dissolution Testersp/n Description
74-201-006 Vision G2 Classic 6 Dissolution Tester• 6-Vessel• Fixed Head• Low-cost & Compact
74-101-008 Vision G2 Elite 8 Dissolution Tester• 8-Vessel• Easi-Lift• Automation-ready
74-101-018 Vision G2 Elite 8 2 Liter High Stand Dissolution Tester• 8-Vessel• 2 Liter• Easi-Lift• Automation-ready
Vision G2 Classic 6 Vision G2 Elite 8
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Testers3
Vision G2 Dissolution Testers
Vision® G2 Classic 6™ & Elite 8™ Features
Fixed drive head
6 Precision drive spindles with spindle shafts
6-Position Easi-Lock™ vessel plate
Compact footprint (2 across & 3 deep)
Easi-Lift™ moveable drive head with multi-lock positions
8 Precision drive spindles with spindle shafts (use 6, 7, or 8)
8-Position Easi-Lock™ vessel plate (use 6, 7, or 8 vessels)
Standard footprint (4 across & 2 deep)
Automation-ready (with optional AutoMag™ & SuperMag™)
Precision control for speed 25-250 rpm, temperature 25-55 ºC
Elegant, ergonomic design with workhorse performance
Highest quality components and engineering
Minimal user adjustments for easy set up and go
Independent Vision® heater circulator system
Rugged molded waterbath with fast heat-up & low level drain
Digital temperature probe (1) for use in bath and vessels
Full color touchscreen with intuitive menus and programming
Up to 100 protocols (create, manage and save routines)
Upload & download programs with flash drive
Electronics and firmware include 32-bit digital technology
Print to both serial and network printers
Alarms for sampling, maintenance and calibration
ISO 9001 quality certified
21 CFR Part 11 security compliant
USP / FDA / ASTM / EP / JP compliant
CE / CSA / RoHS compliant, includes earth-friendly packing
Cla
ssic
6TM
(6-V
esse
l)
Elite
8TM
(8-V
esse
l)
Standard Features
Vision G2 Heater
Manual ProbeTouchscreen Display
Flash Drive
4 Vision Dissolution Testers | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Testers
Cla
ssic
6TM
(6-V
esse
l)
Elite
8TM
(8-V
esse
l)
Accessory Options
Easi-Lock™ USP 1 L precision vessels
Detachable USP paddles and baskets with spin-shafts
ASTM Certificate of Conformity included with USP accessories
Easi-Lock™ vessel covers
ADD™ (Auto-Dosage Delivery) vessel covers
Fixed vessel-mount sample probes with cartridge filters
Wide choice of sample filters (tip, cartridge, and in-line)
In-line filter block kit (for manual and automated sampling)
Serial printer with non-thermal paper
USP apparatus 5 paddle over disk
USP apparatus 6 rotating cylinder
Small volume vessels using “mini-paddle”
Immersion cell for semisolids (small volume)
Wide array of sinkers, holders for accessories, and more
Precision calibration tools
Hanson Q-Pak™ functional validation guideline (USP & ASTM)
HRCare™ IQ/OQ/PQ validation and support program
Media prep and deaeration with Hanson Media-Mate Plus™
2 Liter “high stand” for large volume testing
Easi-Lock™ USP 2 L precision vessels
AutoMag™ (for 1 L and 2 L autosampling)
SuperMag™ (switchable for 1 L and small volume autosampling)
Inert easy-change sample probes for AutoMag™ & SuperMag™
Digital Temperature Probes (DTPs) for each vessel(DTPs are ordered with AutoMag™ & SuperMag™)
Vision® G2 Classic 6™ & Elite 8™ Accessories
Basket, Shaft, Paddle
Sample Filter
Easi-Lock Vessel Small Volume assembly with Immersion Cell
SuperMag
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Testers5
Vision G2 Dissolution Testers
Vision® G2 Classic 6™ Dissolution Tester
Vision G2 Classic 6 Dissolution Tester
The Vision G2 Classic 6 is a compact, rugged workhorse ideal for manual testing. The Classic 6 is precision engineered for USP <711> Dissolution, and includes a unique award-winning footprint designed for saving space and ease of use. Features include a Vision heater system, molded waterbath, 6-position Easi-Lock vessel plate, fixed head with 6 precision drive spindles, and color touchscreen programming with up to 100 protocols.
Paddles, Baskets, and Holdersp/n Description
74-105-201 Spin-Paddle, USP, PVDF (serialized)
74-105-202 Spin-Paddle, USP, 316 SS (serialized)
74-105-251 Spin-Basket Shaft, USP, 316 SS (serialized)
74-105-252 Basket, USP, Precision, 40 Mesh, 316 SS (serialized)
74-105-240 Apparatus 6 Rotating Cylinder, USP (only) (serialized) (min. order 6)
74-105-241 Apparatus 6 Rotating Cylinder with Extension (serialized, requires spacer 74-105-243 1 per position) (min. order 6)
74-105-243 Spacer, Height, Apparatus 6 Rotating Cylinder (required with App 6 p/n 74-105-241; 1 per position)
74-104-280 Apparatus Tray, Stackable, Vision 1 L (see page 13 for description)
Choose Your Vision G2 Accessories
p/n Description
74-201-006 Classic 6 Dissolution Tester, Vision G2
Spin-Paddle
Spin Shaft
Spin-Basket Shaft and Basket
Vision G2 Classic 6 Dissolution Tester
6 Vision Dissolution Testers | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Testers
Probesp/n Description
74-104-201 Cannula, Manual Sampling, Adjustable, 1/8 in., PEEK (uses Tip Sample Filters or In-Line filters; for all Vision manual sampling except 2 L)Vessel-mount probes are also available for connection to autosampler. See page 15.
91-030-132 Syringe, Disposable, Luer Type 10 mL
91-450-062 Filters, In-Line, 5 micron (75/pk)
Vessels and Vessel Coversp/n Description
74-104-101 Vessel, Easi-Lock, USP, Precision, 1 L, Glass (serialized)
74-104-102 Vessel, Easi-Lock, USP, Precision, 1 L, Glass, Amber (special order - min. order 6, serialized)
74-104-151 Vessel Cover, Easi-Lock (for 1 or 2 L) (uses Black Plugs 74-107-006, 20/pk)
74-104-152 Vessel Cover, ADD (Auto-Dosage Delivery)
74-107-012 Vessel Cover, Easi-Lock CS, Vision G2
74-107-013 Vessel Cover, ADD CS (Auto-Dosage Delivery)
Q-Paks, Printers, and Accessories(See page 22 for description of Q-Paks)
p/n Description
74-108-005 Q-Pak IQ/OQ/PQ Validation Guideline, Vision USP
74-108-006 Q-Pak IQ/OQ Validation Guideline, Vision ASTM
74-104-060 Printer, Validation, 115 V (order one per instrument)
74-104-061 Printer, Validation, 230 V (order one per instrument)
47-200-703 Paper, Validation Printer (5/pk)
47-200-704 Ribbon, Validation Printer (2/pk)
74-107-005 Tool Kit, Height Set & Check, Vision (set tool for go/no go depth gauge) (order 1 per lab area)
Easi-Lock Vessels
Easi-Lock Vessel Cover ADD Vessel Cover
Manual Sampling Cannula
Easi-Lock CS Cover74-107-012
Easi-Lock ADD CS Cover74-107-013
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Testers7
Vision G2 Dissolution Testers
The Vision G2 Elite 8 is a modern successor to the popular Hanson SR8-Plus. The G2 Elite 8 is a versatile performance machine, built for automation and extended applications. Features include a Vision heater system, molded waterbath, 8-position Easi-Lock vessel plate, Easi-Lift head with 8 precision drive spindles, and color touchscreen programming with up to 100 protocols. Options include the AutoMag with sampling probes and digital temperature probes (DTPs).
p/n Description
74-101-008 Elite 8 Dissolution Tester, Vision G2, 1 L
Vision® G2 Elite 8™ 1 L Dissolution Tester
Vision G2 Elite 8 1 L Dissolution Tester
Paddles, Baskets, and Holdersp/n Description
74-105-201 Spin-Paddle, USP, PVDF (serialized)
74-105-202 Spin-Paddle, USP, 316 SS (serialized)
74-105-251 Spin-Basket Shaft, USP, 316 SS (serialized)
74-105-252 Basket, USP, Precision, 40 Mesh, 316 SS (serialized)
74-105-240 Apparatus 6 Rotating Cylinder (only), (serialized) (min. order 6)
74-105-241 Apparatus 6 Rotating Cylinder with Extension (serialized, requires spacer 74-105-243 1 per position) (min. order 6)
74-105-243 Spacer, Height, Apparatus 6 Rotating Cylinder (required with App 6 p/n 74-105-241; 1 per position)
74-104-280 Apparatus Tray, Stackable, Vision 1 L (see page 13 for description)
Choose Your Vision G2 Accessories
Vessels and Vessel Coversp/n Description
74-104-101 Vessel, Easi-Lock, USP, Precision, 1 L, Glass (serialized)
74-104-102 Vessel, Easi-Lock, USP, Precision, 1 L, Glass, Amber (Special Order—min. 6, serialized)
74-104-151 Vessel Cover, Easi-Lock (for 1 or 2 L) (uses Black Plugs 74-107-006, 20/pk) (compatible with AutoMag)
74-104-152 Vessel Cover, ADD (Auto-Dosage Delivery) (compatible with AutoMag)
74-107-012 Vessel Cover, Easi-Lock CS, Vision G2 (for 1 or 2 L) (compatible with AutoMag and SuperMag)
74-107-013 Vessel Cover, ADD CS (Auto-Dosage Delivery) (compatible with AutoMag and SuperMag)
Spin-Paddle
Spin Shaft
Easi-Lock Vessels
Spin-Basket Shaft and Basket
Vision G2 Elite 8 Dissolution Tester
8 Vision Dissolution Testers | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Testers
Harnesses (One harness is required for AutoMag with AutoProbes. Extra harnesses required for 3-bath system, return to vessel, and vessel-mount probes.)
p/n Description
60-200-706 Tubing Harness, PTFE, 3 ft, 6-Sample, 1/16 in., AutoPlus, AutoMag, SuperMag
60-200-708 Tubing Harness, PTFE, 3 ft, 8-Sample, 1/16 in., AutoPlus, AutoMag, SuperMag
Probesp/n Description
74-105-307 Auto-Probe, 1 L & Small Volume (SV), 1/8 in., PEEK (1) (uses Tip Sample Filters; requires AutoMag or SuperMag and Tubing Harness) (order 6 or 8)
74-104-201 Cannula, Manual Sampling, Adjustable, 1/8 in., PEEK (uses Tip Sample Filters or In-Line filters; for all Vision manual sampling except 2 L)
91-030-132 Syringe, Disposable, Luer Type 10 mL
74-104-204 Probe, Fixed Vessel-Mount Sample, Adjustable, 1/16 in., 316 SS (uses Cartridge Filters; App 5, 1 L, and CSV )
74-104-216 Probes, Sample, Fixed Vessel-Mount, 1/16 in. SS, set/6, Vision G2 (uses Sample Filters or In-Line Filters with Filter Kit 72-300-262; requires 3 ft Tubing Harness 60-200-706)
74-104-218 Probes, Sample, Fixed Vessel-Mount, 1/16 in. SS, set/8, Vision G2 (uses Sample Filters or In-Line Filters with Filter Kit 72-300-262; requires 3 ft Tubing Harness 60-200-708)
74-104-219 Probes, Digital Temperature (set/6) (factory installed) (includes circuit board, G2 AutoMag required)
74-104-210 Probes, Digital Temperature, for All Vision Mags (1)
74-107-706 Auto-Probes, Recirculating, with Tubing Harness, 1 L, PEEK, set/6, Vision G2, Factory Installed (return to vessel; cannot be used with DTPs)
74-107-708 Auto-Probes, Recirculating, with Tubing Harness, 1 L, PEEK, set/8, Vision G2, Factory Installed (return to vessel; cannot be used with DTPs)
74-107-716 Auto-Probes, Recirculating, with Tubing Harness, 1 L, PEEK, set/6, Vision G2, Field Installed (return to vessel; cannot be used with DTPs)
74-107-718 Auto-Probes, Recirculating, with Tubing Harness, 1 L, PEEK, set/8, Vision G2, Field Installed (return to vessel; cannot be used with DTPs)
Q-Paks, Printers, and Accessories(See page 22 for description of Q-Paks)
p/n Description
74-108-005 Q-Pak IQ/OQ/PQ Validation Guideline, Vision USP
74-108-006 Q-Pak IQ/OQ Validation Guideline, Vision ASTM
74-104-060 Printer, Validation, 115 V (order one per instrument)
74-104-061 Printer, Validation, 230 V (order one per instrument)
47-200-703 Paper, Validation Printer (5/pk)
47-200-704 Ribbon, Validation Printer (2/pk)
74-107-005 Tool Kit, Height Set & Check, Vision (set tool for go/no go depth gauge) (order 1 per lab area)
Choose Your Mag, Harness & Probes(Factory installed; includes probe fittings)
AutoMag
Magazines (for automated sampling) (Also available as a field-installed upgrade to existing Vision G2 Elite 8 systems)
p/n Description
74-107-010 AutoMag Assembly, 1 L (factory installed)
74-107-020 SuperMag Assembly, Small volume & 1 L (factory installed)
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Testers9
Vision G2 Dissolution Testers
The Vision Elite 8 is available in an expanded 2 L “High Stand” configuration. Large-volume 2 L testing is sometimes preferred for high-concentration drug formulations. The 2 L Elite 8 system with its deeper waterbath allows for dissolution testing with traditional 1 L vessels, as well as with larger-volume 2 L vessels. The AutoMag is also available in a 2 L configuration for automatic sampling and Digital Temperature Probes. The 2 L Elite 8 may be ordered direct from the factory; a 2 L Conversion Kit is also available for 1 L system field retrofits.
1 L and 2 L vessels, paddles, basket shafts, probes and other accessories are ordered separately.
p/n Description
74-101-018 Elite 8 Dissolution Tester, Vision G2, 2 L High Stand
74-107-025 Elite 8 “High Stand” 2 L Field Conversion Kit (Converts your Vision G2 Elite 8 1 L tester to a 2 L tester. Includes extended bath and frame extensions. 2 L AutoMag, vessels, extra long paddles and/or basket shafts and sampling probes must be ordered separately.)
Vision® G2 Elite 8™ 2 L Dissolution Tester
Vision G2 Elite 8 High Stand 2 L Dissolution Tester
Paddles, Baskets, and Holdersp/n Description
74-105-351 Spin-Paddle, USP, PVDF, 2 L (serialized)
74-105-361 Spin-Paddle, USP, 316 SS, 2 L (serialized)
74-105-371 Spin-Basket Shaft, USP, 316 SS, 2 L (serialized)
74-105-252 Basket, USP, Precision, 40 Mesh, 316 SS (serialized)
74-104-270 Apparatus Tray, Stackable, Vision 2 L, SR8-Plus (see page 13 for description)
Choose Your Vision G2 Accessories
Spin-Paddle
Spin Shaft
Spin-Basket Shaft and Basket
Vision G2 Elite 8 High Stand 2 L Dissolution Tester
10 Vision Dissolution Testers | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Testers
Q-Paks, Printers, and Accessories(See page 22 for description of Q-Paks)
p/n Description
74-108-005 Q-Pak IQ/OQ/PQ Validation Guideline, Vision USP
74-108-006 Q-Pak IQ/OQ Validation Guideline, Vision ASTM
74-104-060 Printer, Validation, 115 V (order one per instrument)
74-104-061 Printer, Validation, 230 V (order one per instrument)
47-200-703 Paper, Validation Printer (5/pk)
47-200-704 Ribbon, Validation Printer (2/pk)
74-107-005 Tool Kit, Height Set & Check, Vision (set tool for go/no go depth gauge) (order 1 per lab area)
Magazines (for automated sampling) (Also available as a field-installed upgrade to existing Vision G2 Elite 8 systems.)
p/n Description
74-107-040 AutoMag Assembly, 2 L (factory installed)
Harnesses (One harness is required for AutoMag with AutoProbes. Extra harnesses required for 3-bath system, recycle to vessel, and vessel-mount probes.)
p/n Description
60-200-706 Tubing Harness, PTFE, 3 ft, 6-Sample, 1/16 in., AutoPlus, AutoMag, SuperMag
60-200-708 Tubing Harness, PTFE, 3 ft, 8-Sample, 1/16 in., AutoPlus, AutoMag, SuperMag
Probesp/n Description
74-105-327 Auto-Probe, 2 L, 1/8 in., PEEK (1) (uses Tip Sample Filters; requires AutoMag & harness) (order 6 or 8)
74-105-360 Cannula, Manual Sampling, 2 L, 1/8 in., PEEK (uses Tip Sample Filters or In-Line filters; for G2 Elite 8 2 L only)
91-030-132 Syringe, Disposable, Luer Type 10 mL
74-104-204 Probe, Fixed Vessel-Mount Sample, 1/16 in., Adjustable, 316 SS, 2 L (uses Cartridge Filters; App 5, 1 L, and CSV )
74-105-370 Probe, Fixed Vessel-Mount Sample, 316 SS, 2 L (uses Cartridge Filters; requires 3 ft Tubing Harness 60-200-706/708)
74-104-219 Probes, Digital Temperature (set/6) (factory installed) (includes circuit board, G2 AutoMag required)
74-104-210 Probes, Digital Temperature, for All Vision Mags (1) (factory installed)
Note: Digital Temperature Probes are designed for 1 L vessels and a minimum media volume must be at or above 1500 mL in a 2 L vessel for these temperature probe to be adequately submerged. 2 L sampling probes are longer than the temperature probes and can sample solutions down to 1125 mL.
Choose Your Mag, Harness & Probes(Factory installed; includes probe fittings)
Vessels and Vessel Coversp/n Description
74-104-111 Vessel, Easi-Lock, USP, Precision, 2 L, Glass (serialized)
74-104-112 Vessel, Easi-Lock, USP, Precision, 2 L, Glass, Amber (Special Order—min. 6, serialized)
74-104-151 Vessel Cover, Easi-Lock (for 1 or 2 L) (uses Black Plugs 74-107-006, 20/pk) (compatible with AutoMag)
74-104-152 Vessel Cover, ADD (Auto-Dosage Delivery) (compatible with AutoMag)
74-107-012 Vessel Cover, Easi-Lock CS, Vision G2 (for 1 or 2 L) (compatible with AutoMag and SuperMag)
74-107-013 Vessel Cover, ADD CS (Auto-Dosage Delivery) (compatible with AutoMag and SuperMag)
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Test Supplies & Accessories11
Vision G2 Dissolution Accessories
Paddles p/n Description
74-105-201 Spin-Paddle, USP, PVDF, 1 L (serialized)
74-105-202 Spin-Paddle, USP, 316 SS, 1 L (serialized)
74-105-351 Spin-Paddle, USP, PVDF, 2 L (serialized) (for G2 Elite 8 2 L only)
74-105-361 Spin-Paddle, USP, 316 SS, 2 L (serialized) (for G2 Elite 8 2 L only)
74-105-203 * Mini Spin-Paddle, PTFE Coated, Small Volume (SV) (serialized)
74-105-204 * Mini Spin-Paddle, 316 SS, Small Volume (SV) (serialized)
74-105-290 * Mini Spin-Paddle, 316 SS, Chinese Small Volume (CSV)
Baskets p/n Description
74-105-251 Spin-Basket Shaft, USP, 316 SS, 1 L (serialized)
74-105-371 Spin-Basket Shaft, USP, 316 SS, 2 L (serialized)
74-105-252 Basket, USP, Precision, 40 Mesh, 316 SS (serialized)
74-105-221 * Mini Basket, 40 Mesh, 316 SS (serialized)
74-105-220 * Mini Spin-Basket Shaft, 316 SS, Small Volume (SV) (serialized) (requires 74-105-221)
65-700-048 Suppository Basket
74-105-240 * Apparatus 6 Rotating Cylinder (only), (serialized)
74-105-241 * Apparatus 6 Rotating Cylinder with Extension (serialized, requires spacer 74-105-243; 1 per position)
74-105-243 * Spacer, Height, Apparatus 6 Rotating Cylinder (required with App 6 p/n 74-105-241; 1 per position)
95-590-150 * Stationary Basket, 8 Mesh, 316 SS, for Felodipine tablets (see pg. 29) (requires Cover p/n 74-107-019)
74-107-019 * Stationary Basket CS Cover, Vision (required with Stationary Basket p/n 95-590-150)
Vision® Dissolution Test Supplies & Accessories
* Special Order—min. 6
* Special Order—min. 6
12 Vision Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Accessories
Vessels and Covers (See page 18 for Small Volume options)Hanson Precision USP vessels have been an industry standard for many years. These precision vessels, manufactured of quality borosilicate glass, meet or exceed USP <711> vessel dimensions and are an excellent choice for dissolution testing, including ASTM requirements. Vision “Easi-Lock” precision vessels include rugged CPVC tops for easy lock-in position in the vessel plate, and no more accidental chipping of glass vessel lids.
p/n Description
74-104-101 Vessel, Easi-Lock, USP, Precision, 1 L, Glass (serialized)
74-104-102 Vessel, Easi-Lock, USP, Precision, 1 L, Glass, Amber (Special Order—min. 6, serialized)
74-104-111 Vessel, Easi-Lock, USP, Precision, 2 L, Glass (serialized)
74-104-112 Vessel, Easi-Lock, USP, Precision, 2 L, Glass, Amber (Special Order—min. 6, serialized)
74-104-131 Vessel, Easi-Lock, Peak USP Precision, 1 L, Glass
74-104-132 Vessel, Easi-Lock, Peak USP Precision, 1 L, Glass, Amber
74-104-151 Vessel Cover, Easi-Lock (for 1 or 2 L) (uses Black Plugs 74-107-006, 20/pk) (compatible with AutoMag)
74-104-152 Vessel Cover, ADD (Auto-Dosage Delivery) (compatible with AutoMag)
74-107-012 Vessel Cover, Easi-Lock CS, Vision G2 only (for 1 or 2 L) (compatible with AutoMag and SuperMag)
74-107-013 Vessel Cover, ADD CS, Vision G2 only (Auto-Dosage Delivery) (compatible with AutoMag and SuperMag)
72-800-430 Vessel Hole Cover
Easi-Lock vessels come with individual serial numbers and a USP Certificate of Conformity (COC), and are available for Hanson Vision Classic 6 and Elite 8 dissolution testers. (See HRCare—ASTM Program for more COC information.)
Easi-Lock Vessel
Easi-Lock Cover74-104-151
ADD Cover for Vision74-104-152
ADD Cover for Vision74-104-152
Loading Chamber
Trigger
Easi-Lock 1 L Vessels
Easi-Lock CS Cover74-107-012
Easi-Lock ADD CS Cover74-107-013
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Test Supplies & Accessories13
Vision G2 Dissolution Accessories
Universal Vessel Carrier, 6 Position95-590-069
Universal Vessel Carrier, 8 Position95-590-070
Vessel CarriersMade of all non-corrosive rigid ABS plastic construction with sturdy non-skid rubber legs, these vessel carriers transport filled vessels to and from media prep stations and dissolution baths. Holds all brands of 1 liter and 2 liter dissolution vessels. Space-saving stackable design when empty. p/n Description
95-590-069 Universal Vessel Carrier, 6 Position
95-590-070 Universal Vessel Carrier, 8 Position
Vision Apparatus TraysMade from sturdy PVC, this compact tray is the safest and most convenient method of storing spin-paddles, spin-basket shafts and baskets. These stackable trays keep the shafts straight and protected while minimizing bench space. Apparatus Tray p/n 74-104-280 is designed to hold the Hanson Vision 1 L basket shafts, paddles, and baskets, and any competitor 9-inch basket shaft and/or 9.5-inch paddle. Apparatus Tray p/n 74-104-270 is designed to accommodate basket shafts, paddles, and baskets for Vision 2 L, SR8-Plus, and any 15-inch competitor basket shaft and/or paddle. The convenient numbering system also helps keep baskets and shafts organized by position number for ASTM compliance. Protect your investment by protecting the integrity of your apparatus!p/n Description
74-104-280 Apparatus Tray, Stackable, Vision 1 L
74-104-270 Apparatus Tray, Stackable, Vision 2 L, SR8-Plus
Printersp/n Description
74-104-060 Printer, Validation, Classic 6 & Elite 8,115 V (uses non-thermal paper rolls; 1 printer per bath required)
74-104-061 Printer, Validation, Classic 6 & Elite 8, 230 V (uses non-thermal paper rolls; 1 printer per bath required)
47-200-703 Paper, Validation Printer (5/pk)
47-200-704 Ribbon, Validation Printer (2/pk)
Validation Printer
Apparatus Tray (1 L) 74-104-280 Apparatus Tray (2 L) 74-104-270(shown stacked)
14 Vision Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Accessories
Factory Installed
p/n Description
74-107-010 AutoMag Assembly, 1 L (factory installed)
74-107-020 SuperMag Assembly, Chinese Small Volume, Small Volume, & 1 L (factory installed)
74-107-040 AutoMag Assembly, 2 L (factory installed)
Note: Harness and probes are factory installed on magazine only when ordered together.
Field Installed (probes and harnesses sold separately)
p/n Description
74-107-011 AutoMag Assembly, 1 L (field installed)
74-107-021 SuperMag Assembly, Chinese Small Volume, Small Volume, & 1 L (field installed)
74-107-041 AutoMag Assembly, 2 L (field installed)
Vision G2 AutoMag Vision G2 SuperMag (Accommodates 1 L, CSV, SV)
Magazines for Vision G2 Elite 8 (All mags include probe fittings)
The AutoMagTM and SuperMagTM both accommodate Auto-ProbesTM, for automatic sampling from each vessel with the Vision G2 AutoPlus, and Digital Temperature Probes for individual temperature readings in each vessel. Each mag requires a tubing harness.
See next page for Auto-Probes, Digital Temperature Probes (DTPs), and harnesses.
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Test Supplies & Accessories15
Vision G2 Dissolution Accessories
Probes, Cannulas, & Harnessesp/n Description
74-104-201 Cannula, Manual Sampling, Adjustable, 1/8 in., PEEK (uses Tip Sample Filters or In-Line filters; for all Vision manual sampling except 2 L)
74-105-360 Cannula, Manual Sampling, 2 L, 1/8 in., PEEK (uses Tip Sample Filters or In-Line filters; for G2 Elite 8 2 L only)
91-030-132 Syringe, Disposable, Luer Type 10 mL
74-104-202 Probe, Sample, Fixed Vessel-Mount, 500 mL, 1/16 in., 316 SS (uses Cartridge Filters; requires Tubing Harness 60-200-706/708)
74-104-203 Probe, Sample, Fixed Vessel-Mount, 900 mL, 1/16 in., 316 SS (uses Cartridge Filters; requires Tubing Harness 60-200-706/708)
74-104-204 Probe, Sample, Fixed Vessel-Mount, Adjustable, 1/16 in., 316 SS (uses Cartridge Filters; App 5, 1 L, and CSV ) (requires Tubing Harness 60-200-706/708)
74-104-205 Return Port Fitting (return to vessel) (requires 3 ft Tubing Harness 60-200-706/708)
74-104-211 Probe, Sample, Fixed Vessel-Mount, Adjustable, 1/16 in., 316 SS (uses Cartridge Filters; Small Volume only) (requires Tubing Harness)
74-104-216 Probes, Sample, Fixed Vessel-Mount, 1/16 in. SS, set/6, Vision G2 (uses In-Line Filters with Filter Kit 72-300-262; requires 3 ft Tubing Harness 60-200-706)
74-104-218 Probes, Sample, Fixed Vessel-Mount, 1/16 in. SS, set/8, Vision G2 (uses In-Line Filters with Filter Kit 72-300-262; requires 3 ft Tubing Harness 60-200-708)
74-105-370 Probe, Sample, Fixed Vessel-Mount, 316 SS, 2 L (uses Cartridge Filters; requires 3 ft. Tubing Harness 60-200-706/708)
74-105-307 Auto-Probe, 1 L, 1/8 in., PEEK, Vision G2 (uses Tip Sample Filters; requires AutoMag or SuperMag and Tubing Harness)
74-105-327 Auto-Probe, 2 L, 1/8 in., PEEK, Vision G2 (uses Tip Sample Filters; requires AutoMag or SuperMag and Tubing Harness)
74-104-219 Probe, Digital Temperature, (set/6) (includes circuit board; G2 Mag required)
74-104-210 Probe, Digital Temperature Probe, for all Vision Mags (1)
74-104-221 Probe, Digital Temperature, (set/6) (field installed) (ncludes circuit board; G2 Mag required)
74-107-706 Auto-Probes, Recirculating, with Tubing Harness, 1 L, PEEK, set/6, Vision G2, Factory Installed (return to vessel)
74-107-708 Auto-Probes, Recirculating, with Tubing Harness, 1 L, PEEK, set/8, Vision G2, Factory Installed (return to vessel)
74-107-716 Auto-Probes, Recirculating, with Tubing Harness, 1 L, PEEK, set/6, Vision G2, Field Installed (return to vessel)
74-107-718 Auto-Probes, Recirculating, with Tubing Harness, 1 L, PEEK, set/8, Vision G2, Field Installed (return to vessel)
Manual Sampling Cannula74-104-201
Harnesses (One harness is required for AutoMag with AutoProbes. Extra harnesses required for 3-bath system, recycle to vessel, and vessel-mount probes.)
p/n Description
60-200-706 Tubing Harness, PTFE, 3 ft, 6-Sample, 1/16 in., AutoPlus, AutoMag, SuperMag
60-200-708 Tubing Harness, PTFE, 3 ft, 8-Sample, 1/16 in., AutoPlus, AutoMag, SuperMag
Fixed Vessel-Mount Sample Probes (set/8)
74-104-218
Return Port Fitting
Fixed Vessel-Mount Sample Probe
(Adjustable shown)74-104-204
Cartridge Filter Chamber
16 Vision Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Accessories
Tip Sample Filters (for Auto-Probes; 100% Porous Polyethylene)
p/n Description
27-101-087 Filters, Sample, 1 micron, 1/8 in. (100/pk)
27-101-097 Filters, Sample, 1 micron, 1/8 in. (1,000/pk)
27-101-088 Filters, Sample, 4 micron, 1/8 in. (100/pk)
27-101-098 Filters, Sample, 4 micron, 1/8 in. (1,000/pk)
27-101-074 Filters, Sample, 10 micron, 1/8 in. (100/pk)
27-101-091 Filters, Sample, 10 micron, 1/8 in. (1,000/pk)
27-101-083 Filters, Sample, 10 micron, 1/16 in. (100/pk)
27-101-093 Filters, Sample, 10 micron, 1/16 in. (1,000/pk)
27-101-085 Filters, Sample, 35 micron, 1/8 in. (100/pk)
27-101-095 Filters, Sample, 35 micron, 1/8 in. (1,000/pk)
27-101-086 Filters, Sample, 35 micron, 1/16 in. (100/pk)
27-101-096 Filters, Sample, 35 micron, 1/16 in. (1,000/pk)
27-101-089 Filters, Sample, 45 micron, 1/8 in. (100/pk)
27-101-090 Filters, Sample, 45 micron, 1/16 in. (100/pk)
27-101-082 Filters, Sample, 70 micron, 1/8 in (100/pk)
27-101-092 Filters, Sample, 70 micron, 1/8 in (1,000/pk)
27-101-084 Filters, Sample, 70 micron, 1/16 in (100/pk)
27-101-094 Filters, Sample, 70 micron, 1/16 in (1,000/pk)
Tip Sample Filters, PVDF (for Auto-Probes)
p/n Description
27-101-101 Filters, Sample, 10 micron, 1/8 in., PVDF (100/pk)
27-101-102 Filters, Sample, 10 micron, 1/8 in., PVDF (1,000/pk)
Cartridge Filters (for Vision Fixed Vessel-Mount Probes; 100% Porous Polyethylene)
p/n Description
74-104-301 Cartridge Filters, 10 micron, Vision (100/pk)
74-104-302 Cartridge Filters, 10 micron, Vision (1,000/pk)
74-104-303 Cartridge Filters, 35 micron, Vision (100/pk)
74-104-304 Cartridge Filters, 35 micron, Vision (1,000/pk)
74-104-307 Cartridge Filters, 70 micron, Vision (100/pk)
74-104-308 Cartridge Filters, 70 micron, Vision (1,000/pk)
In-Line Filtersp/n Description
61-107-010 Filter Block Kit for In-Line Filters (uses In-Line Filters 91-450-062)
72-300-262 In-Line Filter Kit
91-450-062 Filters, In-Line, 5 micron (75/pk)
Filters
Sample Filter
In-Line Filter Kit72-300-262
In-Line Filter91-450-062 (not included
in kit)
Cartridge Filter
Filter Block Kit61-107-010
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Test Supplies & Accessories17
Vision G2 Dissolution Accessories
USP Apparatus 5 “Paddle Over Disk” (“Transdermal Sandwich”)The USP Apparatus 5 “Paddle Over Disk” (Transdermal Sandwich) is a convenient disk assembly recommended by the FDA for testing patch dosage forms in a standard dissolution test station. The App 5 Transdermal Sandwich consists of a glass watchglass (on which the patch is placed, delivery side up), a 17 mesh PVDF screen (to hold the patch), and PVDF clips to hold the disk assembly together. For use with standard USP 1 liter vessel and paddle. Accommodates patches up to 90 mm diameter. Used on all Hanson dissolution testers.
p/n Description
65-190-092 Transdermal Sandwich for Patch (App. 5) (for Vision, requires Spacer 74-105-244 - 1 per position)
65-190-093 Transdermal Sandwich for Patch (App. 5) (set/6) (for Vision, requires Spacer 74-105-244 - 1 per position)
74-105-244 Spacer, Height, for Apparatus 5, Vision (1 per position, required with 65-190-092/093) App. 5 Transdermal Sandwich
Sinkers (for all Hanson dissolution systems)
p/n Description
65-190-012 Sinkers (6/pk) (wt 1.3 g; 9.5 mm x 25 mm capacity)
65-190-013 Sinkers (12/pk) (wt 1.3 g; 9.5 mm x 25 mm capacity)
65-700-316 Wire, 316 SS (50 ft roll)
95-590-021 Sinker, Spiral Coated (0.90 in. x 0.37 in. capacity)
95-590-022 Sinker, Spiral Uncoated, 316 SS (0.90 in. x 0.37 in. capacity)
95-590-023 Sinker, Spiral Coated (1.02 in. x 0.38 in. capacity)
95-590-024 Sinker, Spiral Uncoated, 316 SS (1.02 x 0.38 in. capacity)
95-590-025 Sinker, 3 Prong
95-590-026 Sinker, Japanese Pharmacopoeia Cage
Sprial coated sinkers are coated with 100% inert epoxy.
Sinker65-190-012/013
Sprial Coated Sinker95-590-021
Spiral Uncoated Sinker95-590-024
3 Prong Sinker95-590-025
Japanese Pharmacopoeia Cage Sinker95-590-026
18 Vision Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Accessories
Small Volume Dissolution AccessoriesUsed for low concentration drug formulations and other special applications when small volume dissolution media is required. Provides everything you need to convert from the standard USP 1 liter vessel and paddle to small volume testing. The 150 mL round-bottom vessel is patterned after the standard USP 1 liter vessel. The 150 mL flat-bottom vessel is used with the Hanson Immersion Cell. The mini spin-paddle is patterned after the standard USP Apparatus 2 paddle. Consult Hanson for special mini-basket and other special requirements.
Vessel Cover
Easi-Lock Adapter Ring
Round-Bottom Vessel
Mini Spin-Paddle
Fixed Vessel-Mount Sample Probe
Small Volume—Round Bottom
* Special Order—min. 6
1. For Automated Elite 8 Sampling
p/n Description
74-107-020 SuperMag Assembly (factory istalled)
74-107-021 SuperMag Assembly (field istalled)
2. Choose your Small Volume Vessel
p/n Description
74-105-151 Vessel, Round Bottom, 150 mL, Glass (serialized)
74-105-161 * Vessel, Round Bottom, 150 mL, Glass, Amber (serialized)
74-105-152 Vessel, Flat Bottom, 150 mL, Glass (serialized)
74-105-162 * Vessel, Flat Bottom, 150 mL, Glass, Amber (serialized)
3. Choose your Paddle and/or Basket
p/n Description
74-105-203 Mini Spin-Paddle, PTFE Coated (serialized)
74-105-204 Mini Spin-Paddle, 316 SS (serialized)
74-105-221 * Mini Basket, 40 Mesh, 316 SS (serialized) (requires 74-105-220)
74-105-220 * Mini Spin-Basket Shaft, 316 SS (serialized)
4. Choose your Probe
p/n Description
74-104-201 Manual Sampling Cannula, Adjustable, 1/8 in., PEEK
91-030-132 Syringe, Disposable, Luer Type 10 mL
74-104-211 Fixed Vessel-Mount Sample Probe, Adjustable, 1/16 in., 316 SS (small volume only)
74-104-216 Probes, Sample, Fixed Vessel-Mount, 900 mL,1/16 in. SS, set/6, Vision G2 (uses Sample Filters or In-Line Filters; requires 3 ft Tubing Harness 60-200-706)
74-104-218 Probes, Sample, Fixed Vessel-Mount, 900 mL,1/16 in. SS, set/8, Vision G2 (uses Sample Filters or In-Line Filters; requires 3 ft Tubing Harness 60-200-708)
74-105-307 Auto-Probes, 1L, 1/8 in., PEEK, Vision G2 (requires AutoMag or SuperMag and Tubing Harness)
5. Add one each per position
p/n Description
74-104-163 Vessel Cover, CS (for small volume vessels)
74-104-155 Easi-Lock Adapter Ring (for small volume vessels)
74-104-205 Return Port Fitting (optional)Small Volume Adapter and Cover
Vessel Cover
Easi-Lock Adapter Ring
Round-Bottom Vessel
Mini Spin-Paddle
Manual Sampling Cannula
Small Volume—Round Bottom
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Test Supplies & Accessories19
Vision G2 Dissolution Accessories
Return Port Fitting (optional)
Vessel Cover
Easi-Lock Adapter RingFlat-Bottom Vessel Mini Spin-Paddle
Immersion Cell
Small Volume—Flat Bottom
Membrane Area
Dosage Area
Immersion Cell(cross section)
p/n Description
65-190-043 Immersion Cell, 15 mm (cell only)
65-190-051 Immersion Cell, 15 mm (1 cell w/ tools)
65-190-052 Immersion Cell, 15 mm (set/6 w/ tools)
The Hanson Immersion Cell is designed for use with the flat-bottom vessel to eliminate dead volume. The cell uses standard 25 mm filter disks, and its 3 mm deep dosage area provides for testing of infinite dose topical applications. Immersion Cells with convenient assembly tool and grip tool are available as a set; extra cells may be ordered separately. Designed for release-rate testing of ointments and other topical preparations in the convenience of standard dissolution test equipment. See USP <1724> for further information.
Immersion Cell (for flat-bottom small volume vessels; order one for each position)
The Hanson Chinese Small volume (CSV) dissolution system is based on the official method listed in the Chinese pharmacopeia. The CSV system includes a larger media vessel (250 mL typical) than the traditional small volume dissolution method (100-150 mL typical) commonly used in some special applications. The CSV adapts to Hanson Vision dissolution testers, and provides a mid-range volume for applications that require less media volume than standard 500 or 900 mL dissolution tests, but more than traditional small volume. Fixed vessel-mount probes or the SuperMag (Elite 8) are used. The CSV vessel has an inside diameter of 62 mm (+/- 3 mm) in conformance with the Chinese pharmacopeia, and it is available in both clear and amber glass.
p/n Description
74-104-173* Vessel Cover, CSV
74-104-175* Adapter Ring Assembly, CSV (required)
74-105-280* Vessel, Round Bottom, 250 mL, Clear Glass, CSV (serialized)
74-105-281* Vessel, Round Bottom, 250 mL, Amber Glass, CSV (serialized)
74-105-290* Mini Spin-Paddle, 316 SS, CSV (serialized)
Chinese Small Volume Assembly
Chinese Small Volume (CSV) Accessories (order one for each position)
* Special Order; min. 6 pcs.
20 Vision Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Accessories
Conversion & Upgrade KitsConvert your Vision G1 dissolution tester to a G2 compatible tester with our NEW Vision G2 Dissolution Conversion Kits. A Vision G2 Classic 6 or Elite 8 Conversion Kit will give you everything you need to upgrade your Vision G1 tester to full compatibility with our new Vision G2 Autosampler and AutoFill Collector, including G2 boards, display, power supply, firmware upgrade, upgrade parts, and flash drive accessory kit.
Conversion Kits and Options (Note: Only the G2 AutoMag or SuperMag is compatible with a G2 Upgrade of the Elite 8.)
p/n Description
74-107-016 Classic 6 Conversion Kit (Upgrades an original Classic 6 to a G2 Classic 6)
74-107-018 Elite 8 Conversion Kit (Upgrades an original Elite 8 to a G2 Elite 8)
74-107-025 Elite 8 “High Stand” 2 L Field Conversion Kit (Converts your Vision G2 Elite 8 1 L tester to a 2 L tester. Includes extended bath and frame extensions. 2 L AutoMag, vessels, extra long paddles and/or basket shafts and sampling probes must be ordered separately.)
74-107-035 AutoMag, 1 L to 2 L Conversion Kit (Converts your 1 L AutoMag to a 2 L AutoMag)
74-107-045 AutoMag to SuperMag Conversion Kit (Converts your Vision G2 1 L AutoMag to a SuperMag) (Gives you the versatility of both 1 L and Small Volume autosampling capability.)
74-104-220 DTP Conversion Kit (No Probes) (Upgrades Digital Temperature Probes on a G1 system for use on a G2 system. G2 AutoMag or SuperMag is required.)
74-103-041 Board, PC-Mag, for DTP (for service only; does not include probes) (Upgrades G1 to G2 DTP board.)
74-109-021 Firmware Upgrade, Vision G2 Tester (free firmware upgrade via email or Resource Center)
61-109-021 Firmware Upgrade, Vision G2 Autosampler (free firmware upgrade via email or Resource Center)
Certificates & Servicep/n Description
7-920 * Recalibration Service (for calibration tools)
7-909 * Individual Certificate of Conformity for USP Accessory (Special Order)
7-910 * Document Replacement Service for Certificate of Conformity (Special Order)
7-911 * Document Replacement Service for Blank IQ/OQ Protocols(Available to U.S. customers only with proof of related HRCare service purchase)
7-912 * Document Replacement Service for Blank PQ Protocols (Available to U.S. customers only with proof of related HRCare service purchase)
7-930 * Certificate of Analysis for USP Vessel
7-931 * Certificate of Analysis for USP Paddle
7-932 * Certificate of Analysis for USP Basket
7-933 * Certificate of Analysis for USP Basket Shaft
* No discounts apply to p/n 7-XXX. Please supply serial numbers at time of order, if applicable.
Certificates & Service
Hanson Research Corp. hereby certifies that this product was designed, evaluated, validated, inspected, and tested to approved specified quality requirements of Hanson Research Corp. in conformance with current USP <711>, EP (2.9.3), JP (6.10), and ASTM E2503-13 specifications.
The following standards regarding quality assurance requirements were used for this quality analysis:
1. ISO 9001:2008 clause 8.2.4 Monitoring and Measurement of Product
2. ANSI Z1.9 Sampling Procedures and Tables for Inspection by Variables
3. ANSI Z540-1 part 2 Quality Assurance Requirements for Measuring and Test Equipment
9810 Variel Avenue • Chatsworth, CA 91311 USA 800.821.8165 • 818.882.7266 • Fax 818.882.9470 74-108-111 Rev. 11-13
Product Name Easi-Lock Precision Vessel,
1 Liter, Glass, Clear Part Number 74-104-101
Serial Number(s):
1 5 9 2 6 10 3 7 11 4 8 12
Material ............................... Grey CPVC & Borosilicate Glass A. Vessel Height .................................................... 160210 mm B. Vessel Inside Diameter ........................................ 98–106 mm C. Hemispherical Bottom ........................................... 49–53 mm
December 16, 2013
Certificate of Conformity
Design Qualification DQs (Design Qualification documents) are available upon customer request for Hanson equipment. Please consult Hanson for details.
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision Dissolution Test Supplies & Accessories21
Vision G2 Dissolution Accessories
Vision Calibration Tools & Accessoriesp/n Description
65-233-203 Vibration Meter Kit
65-233-301 Digital Tachometer
65-233-402 Digital Thermometer
74-107-002 Digital Level Kit (self-calibrating)(required for Vision dissolution baths and all ASTM bath validation)
74-107-003 O-Ring Tool Kit (service only tool)
74-107-004 Validation Tool Kit (for Vision baths and ASTM validation)
74-107-005 Height Set & Check Kit (set tool for go/no go depth gauge)
74-301-002 Vision Heater Assembly, 115/230 V
91-902-020 Electro-Mechanical Tool Kit
Tool Kits & Accessories
1. Digital Height Gauge
2. Sweep Gauge
3. Height Check Tool
4. Height Set Tool
5. Bubble Level
6. Wobble Gauge
7. Wobble Bracket (non-Vision)
8. Wobble Bracket (Vision)
9. Indicator Bracket
10. Wobble Shaft
11. Sweep Shaft
12. Case (2)
Validation Tool Kit 74-107-004
Vision Testersp/n Description
74-107-000 2-Year Spare Parts Kit, Vision G2, Elite 8
74-207-000 2-Year Spare Parts Kit, Vision G2, Classic 6
Vision AutoPlusp/n Description
61-107-000 2-Year Spare Parts Kit, Vision AutoPlus
61-207-000 2-Year Spare Parts Kit, Vision AutoFill
Vision AutoFilterp/n Description
43-107-000 2-Year Spare Parts Kit, Vision AutoFilter Changer
Vision Spare Parts Kits
22 Vision Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 Dissolution Accessories
Q-Paks, Reference & Calibration Accessoriesp/n Description
74-108-005 Q-Pak IQ/OQ/PQ for Vision Dissolution Testers—USP
74-108-006 Q-Pak IQ/OQ for Vision Dissolution Testers—ASTM
91-951-007 USP Calibrator Tabs, Prednisone (30 tabs) (disintegrating)
91-951-017 USP Standard, Prednisone
91-030-000 Handbook of Dissolution Testing, 3rd EditionDissolution Handbook
91-030-000
Q-Pak™ IQ/OQ/PQ Validation GuidelineThe Hanson Q-Pak addresses manufacturers’ and USP/FDA recommendations for dissolution instrument IQ, OQ, and PQ (Installation, Operation, and Performance Qualifications). This unique guideline directs the user through instrument qualification and documentation of key elements of functional validation. Combined with our easy-to-use calibration tools, the Q-Pak can ensure optimum dissolution performance and maximum regulatory compliance. Q-Paks are ideal guidelines to help develop document system qualification for audit trail.
HRCare provides for U.S. Service and Validation Contracts. See HRCare—Service & Validation Plans for information.
―Functional Validation Guideline 74-108-005-E
Q-Pak for Vision—USP74-108-005
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision AutoPlus23
Vision G2 AutoPlus Autosampling Systems
Vision® G2 AutoPlus™ Autosampling SystemsVision G2 Dissolution Test Instruments are designed for seamless integration, intuitive programming and operation, flexibility to handle a wide range of applications, with maximum throughput and productivity. Design your lab system to handle everything from basic 1-bath routines to extensive multi-bath testing. Collect samples for off-line analysis in UV-Vis, HPLC, or UPLC™ detectors. Connect to a spectrophotometer multi-cell transport for on-line UV analysis.
3-Bath System: Maximizer
Sample3 Baths Detect Collect To Waste
or Retrieval
2-Bath with Media Replace: Maximizer
Detect Collect To Waste
or Retrieval
Sample2 Baths
Media Replace
1-Bath with Media Replace: Maximizer
Detect Collect To Waste
or Retrieval
Sample1 Bath
Media Replace
DetectSample1 Bath Collect To Waste
or Retrieval
Recycle to Vessel
1-Bath Basic System: DissoScan & Maximizer
Vision® G2 AutoPlus™/AutoFill™: DissoScan™ & Maximizer™ Configurations
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision AutoPlus25
Vision G2 AutoPlus Autosampling Systems
24 Vision AutoPlus | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision G2 AutoPlus Autosampling Systems
Vision® G2 AutoPlus™ Autosampler & AutoFill™ Collector
Vision G2 AutoPlus/AutoFill
Vision AutoPlus DissoScan & Maximizer Autosamplersp/n Description
61-101-006 Maximizer, 6-Sample, 115/230 V
61-101-008 Maximizer, 8-Sample, 115/230 V
61-101-016 DissoScan, 6-Sample, 115/230 V
61-101-018 DissoScan, 8-Sample, 115/230 V
Note: Vision G2 AutoPlus requires a Sampler Tray (p/n 61-105-045) if Vision G2 AutoFill is not used or positioned as recommended by the User Guide.
AutoFill Collectorp/n Description
61-201-001 AutoFill Collector, 115/230 V
The Vision G2 AutoPlus is an upgrade of the popular Hanson autosampler. The Vision G2 AutoPlus comes with a choice of 6 or 8 sampling channels, and DissoScan (1-bath) or Maximizer (multi-bath & multi-routine) configurations. Precision syringe pump mechanics, all-inert tubing and valves, and color touchscreen programming with up to 100 protocols are standard on each instrument.
The Vision AutoFill is a newly-engineered collector designed for seamless integration with the G2 AutoPlus. AutoFill accessories include choice of collection racks with 16 x 100 mm test tubes for UV-Vis, 12 x 32 mm vials for HPLC, and sample trays with 12 x 32 mm vials for UPLC.
AutoFill Collector
hansonresearch.com | 99-300-001 Rev. 3-14 | Vision AutoPlus25
Vision G2 AutoPlus Autosampling Systems
Printers, Q-Paks & Accessoriesp/n Description
60-200-706 * Tubing Harness, PTFE, 3 ft, 6 Sample, 1/16 in.
60-200-708 * Tubing Harness, PTFE, 3 ft, 8 Sample, 1/16 in.
61-105-045 Sampler Tray, Vision G2 AutoPlus (Tray required for Vision AutoPlus if AutoFill is not purchased or if AutoFill will not sit on top of AutoPlus as recommended.)
91-215-050 Ethernet Network Switch, 5-Port, 10/100 Mbps, 115/230 V (required for G2 AutoPlus multi-bath and network printer connection) (Requires LAN cable: p/n 91-211-035 [25 ft] or p/n 91-211-036 [7 ft].)
60-200-101 Printer, Validation, 115 V (order one per instrument)
60-200-102 Printer, Validation, 230 V (order one per instrument)
47-200-703 Paper, Validation Printer (5/pk)
47-200-704 Ribbon, Validation Printer (2/pk)
61-108-005 Q-Pak, IQ/OQ/PQ Validation Guidelines, Vision G2 AutoPlus
* One required for AutoMag with AutoProbes. Extra harnesses required for 3-bath system, recycle to vessel, and vessel mount probes.
Retrieval Reservoir and Filters The Vision G2 AutoPlus Retrieval Reservoir is an accessory add-on to the AutoFill collector that eliminates autosampling waste volume. The “retrieval” accessory returns rinse media back to the vessel after UV analysis and/or collection. Easy field retrofit.p/n Description
61-201-011 Retrieval Reservoir (for AutoFill only)
61-107-010 Filter Block Kit for In-Line Filters (uses In-Line Filters p/n 91-450-062; includes [1] 8-sample Tubing Harness)
91-450-062 Filters, In-Line, 5 micron (75/pk) (for Filter Block Kit p/n 61-107-010 or In-Line Filter Fitting Kit p/n 72-300-262)
Racks, Tubes, and Vialsp/n Description
61-201-052 Rack, Collector, for 16 mm x 100 mm Test Tubes
61-201-053 Rack, Collector, for 12 mm x 32 mm HPLC Vials
61-201-054 Rack, Collector, for 12 mm x 32 mm UPLC Vials (requires p/n 61-201-015 Upgrade Kit and 3 UPLC Vial Trays p/n 91-030-159; for use with Waters Acquity UPLC system)
61-201-057 Rack, Collector, for 13 x 100 mm Test Tubes (Special Order)
91-030-159 Vial Tray, 48 Well for 2 mL UPLC vials (requires 3 trays per p/n 61-201-054 UPLC Rack)
61-201-015 Upgrade Kit, AutoFill for UPLC Rack (required for p/n 61-201-054 UPLC Rack)
91-030-051 Test Tubes, 16 mm x 100 mm (250/pk)
27-800-633 Test Tubes, 13 mm x 100 mm (250/pk)
91-030-150 Vials w/ Pre-Cut Septum, HPLC, UPLC, 12 mm x 32 mL (100/pk)
61-107-003 Caps, Evaporation, 16 mm , Reusable (100/pk)
16 x 100 mm Test Tubes AutoFill Rack 12 x 32 mm HPLC Vials AutoFill Rack 12 x 32 mm UPLC Vials AutoFill Rack & Vial Tray (for Waters Acquity UPLC system)
26 AutoFilter Changer | 99-300-001 Rev. 3-14 | hansonresearch.com
Vision AutoFilter Changer
Vision® AutoFilter™ ChangerThe Vision AutoFilter is a filter changer that automatically introduces 25 mm syringe filters into the fluidic path of your dissolution samples. Designed as a seamless addition to Hanson’s Vision family of quality test equipment, the Vision AutoFilter brings a new approach to automated filter changing. It allows you to increase the life of your filters by allowing fluidic steps to take place with or without a filter.
The Vision AutoFilter automatically introduces filters into the fluidic path, removes them if desired, and returns them to position or discards them—all of which is completely programmable. The Vision AutoFilter not only saves you money on filters, but also saves you time by eliminating the need for you to manually disconnect and reconnect fluidic lines. You command whether the Vision AutoFilter operates without filters during sampling, or whether it filters from 6, 7, or 8 lines of samples.
Vision AutoFilter changer
Q-Paks & Accessoriesp/n Description
43-108-005 Q-Pak, IQ/OQ/PQ Validation Guidelines, Vision AutoFilter
43-107-000 2-Year Spare Parts Kit, Vision AutoFilter
The Vision AutoFilter works with a variety of filter brands, including both automation-compatible and non-automation-compatible filters. there are almost no limitations to the Vision AutoFilter—you decide what works best for your method. Patent pending.
The Vision AutoFilter Changer comes with everything needed to interface with Hanson Vision dissolution instruments and the Vision AutoPlus autosampling system. Filter Stack Tubes are included (both 18- and 25-filter capacity) to pre-stack syringe filters for automatic unattended operation during dissolution tests. Filters are sold separately.
p/n Description
43-101-008 Vision AutoFilter Changer
Vision AutoFilter FiltersThe Vision AutoFilter Changer is designed to accommodate many industry-standard 25 mm syringe filters, including:
• Hanson p/n 91-450-062 Filters, In-Line, 5 micron (75/pk) (see page 16)
• Millipore Millex™ Syringe Filter & Automation Compatible Filter
• Pall Acrodisc™ Syringe Filter & Automation Certified Filter
• VWR™ International Syringe Filters
Filters should be validated for suitable use and performance per customer SOP and protocol.
Vision AutoFilter Filters
hansonresearch.com | 99-300-001 Rev. 3-14 | Dissolution Data Management System27
Dissolution Data Management Systems
Dissolution Data Management Systems
IDIS Dissolution Software
IDIS dissolution data management software is an exceptionally capable program that has the ability to control every element of your dissolution station, from tester(s) to sampler to spectrophotometer. With its mix-and-match driver capability and excellent security and auditing features, IDIS can help your lab put a variety of components together to work in your dissolution laboratory, even offering flexibility in designing your 21 CFR 11-compliant reports. Features include a central relational database containing data from any number of networked IDIS workstations, remote LIMS export option, support for closed or open loop UV and HPLC systems, fluorescence and conductivity drivers, and a “queryable” audit trail. IDIS is also compatible with Hanson’s entire line of quality dissolution test instruments (both legacy and Vision).
Contact Info:
Email: mailto:[email protected]
Website: http://www.auto-labsystems.co.uk/
ARGUS Dissolution Software
ARGUS/Dissolution is a cutting-edge scientific software application for pharmaceutical dissolution testing. An all-in-one solution, this software covers the entire laboratory workflow from data acquisition, management, and processing to reporting of analytical results. Its innovative user interface ensures straightforward, secure and compliant operation. Developing methods or running analyses is as easy as working with office software. Features include intuitive wizards, multi-component drug analysis, advanced calibration algorithms, monitoring with USB cameras, profile comparison, relational database technology, and drivers for autosamplers, spectrophotometers, and multiple testers (including Hanson’s Vision family of quality dissolution test instruments, as well as legacy Hanson instruments).
Contact Info:
Email: mailto:[email protected]
Website: http://www.solvias.com/
28 On-Line HPLC System | 99-300-001 Rev. 3-14 | hansonresearch.com
On-Line HPLC System
on-line HplC DiSSolution SyStemHanson Research is pleased to support the On-Line HPLC Dissolution System from Waters Corporation. The Transfer Module, OEM manufactured exclusively for Waters, has been designed for direct interfacing with the Alliance HPLC system with Empower™ software. This complete dissolution test system package is being distributed and supported by Waters worldwide. Full specifications and pricing are available from your local Waters representative.
The Waters Alliance System for Dissolution offers on-line sampling, transfer, and HPLC analysis for 6- and 8-sample dissolution baths. In addition, the Empower dissolution software can provide fast, accurate data reduction and documentation of results. Both the system and the software comply with accepted USP protocols to facilitate meeting regulatory requirements.
Waters On-Line HPLC and Vision G2 Elite 8 Dissolution Tester(2 Tubing Harnesses required per tester)
Required Accessoryp/n Description
47-200-759 Cable, RS-232 Communication, 9 ft.
The Waters HPLC Dissolution System is fully functional with Hanson Vision G2 dissolution testers. Complete dissolution test protocols are provided with the Waters software, and communications with Vision G2 testers are built in for validation of critical dissolution test parameters. The Hanson Vision G2 testers are distributed and supported by Hanson Research worldwide. Please consult Hanson for further details and Vision firmware requirements.
hansonresearch.com | 99-300-001 Rev. 3-14 | SR8-Plus Dissolution Test Supplies & Accessories29
SR8-Plus Dissolution Test Supplies & Accessories
SR8-Plus™ Dissolution AccessoriesThe Hanson SR8-Plus dissolution tester has been discontinued (April 2012), although this product will still be supported for several years. The section that follows includes a wide range of common accessories and consumables for the SR8-Plus. Additional service parts and accesories may be available in our Price Guide.
SR8-Plus Dissolution Tester
Paddlesp/n Description
72-800-456 Paddle, USP, w/ 15 in. Shaft, PVDF
72-800-461 Paddle, USP, w/ 18 in. Shaft, PVDF, “Long”
72-800-457 Paddle, USP, w/ 21 in. Shaft, 2 L, PVDF, “Extra Long”
65-700-036 Paddle, USP, w/ 15 in. Shaft, 316 SS
65-700-037 Paddle, USP, w/ 21 in. Shaft, 2 L, 316 SS, “Extra Long”
72-800-460 Mini-Paddle, PTFE Coated (for 150 mL vessel)
All paddles in this section are serialized.
15 in. 18 in. 21 in. 15 in. 21 in. Mini-Paddle
PVDF (Polyvinylidene Fluoride) 316 Stainless Steel PTFE Coated
Apparatus TrayMade from sturdy PVC, this compact tray is the safest and most convenient method of storing paddles, basket shafts and baskets. These stackable trays keep the shafts straight and protected while minimizing bench space. Designed to accommodate basket shafts, paddles, and baskets for Vision 2 L, SR8-Plus, and any 15-inch competitor basket shaft and/or paddle. The convenient numbering system also helps keep baskets and shafts organized by position number for ASTM compliance. Protect your investment by protecting the integrity of your apparatus!
p/n Description
74-104-270 Apparatus Tray, Stackable, Vision 2 L, SR8-PlusApparatus Tray 74-104-270
30 SR8-Plus Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
SR8-Plus Dissolution Test Supplies & Accessories
Baskets & Shaftsp/n Description
65-240-000 Basket Assembly, USP, w/ 15 in. Shaft (serialized)
65-240-400 Basket Assembly, USP, w/ 21 in. Shaft, 2 L (serialized)
74-105-252 Basket, USP, Precision, 40 Mesh (serialized)
65-220-010 Basket, 10 Mesh, 316 SS (Special Order—min order 6)
65-220-020 Basket, 20 Mesh, 316 SS (Special Order—min order 6)
65-700-048 Suppository Basket (not serialized)
65-237-000 Basket Shaft, USP, 15 in. (serialized)
65-260-000 Basket Shaft, USP, 21 in., 2 L (serialized)
65-590-011 USP Apparatus 6 Rotating Cylinder (max patch area = 5.5 in. x 2 in.)
65-590-013 USP Apparatus 6 with Extension (max patch area w/ extension = 5.5 in. x 5.69 in.)
95-590-150 Stationary Basket, 8 Mesh, 316 SS (Stationary Basket Vessel Cover p/n 95-590-151 sold separately)• Complies with USP Monograph for Felodipine Extended-Release Tablets• Helps with problems associated with floating, sticking, and swelling dosage forms• For convenient installation and removal of the basket and cover assembly, extra-long paddle
shafts recommended• Manual sampling only
95-590-151 Stationary Basket Vessel Cover
All baskets and shafts in this section are serialized unless otherwise indicated. Apparatus 6 Rotating Cylinder and extensions are serialized alike when ordered together.
15 in. 21 in. Basket Suppository 15 in. 21 in. Apparatus 6 & Extension Stationary Basket
Basket Assemblies only basket Shafts
hansonresearch.com | 99-300-001 Rev. 3-14 | SR8-Plus Dissolution Test Supplies & Accessories31
SR8-Plus Dissolution Test Supplies & Accessories
VesselsHanson Precision USP vessels have been an industry standard for many years. These precision vessels, manufactured of quality borosilicate glass, meet or exceed USP <711> vessel dimensions and are an excellent choice for dissolution testing. For labs requiring even tighter manufacturing tolerance and precision in vessel dimensions (such as that required by ASTM E2503-07), new Super Precision vessels are available. Hanson Super Precision vessels are manufactured with a unique proprietary method providing a “super” precision inside diameter and spherical radius.
Both Precision and Super Precision vessels come with individual serial numbers and a USP Certificate of Conformity (COC), and are available for Hanson SR8-Plus dissolution testers. (See HRCare—ASTM Program for more COC information.)p/n Description
72-600-510 Vessel, USP, Precision, 1 L, Glass
91-030-003 Vessel, USP, 1 L, Plastic (not serialized)
72-600-556 Vessel, USP, Precision, 1 L, Glass, Amber (Special Order—min order 6)
72-600-509 Vessel, USP, Precision, 2 L, Glass
72-600-580 Vessel, USP, Precision, 2 L, Glass, Amber (Special Order—min order 6)
72-600-573 Vessel, Round Bottom, 150 mL, Glass
72-600-583 Vessel, Round Bottom, 150 mL, Glass, Amber (Special Order—min order 6)
72-600-572 Vessel, Flat Bottom, 150 mL, Glass
95-590-047 Vessel, Peak, Glass, 1 L (includes Vessel Centering Ring p/n 73-101-515; Special Order—min order 6)
95-590-048 Vessel, Peak, Glass, 1 L , Amber (includes Vessel Centering Ring p/n 73-101-515; Special Order—min order 6)
73-101-515 Vessel Centering Ring (included with Peak Vessels; required for Super Precision Vessels if the Vessel Centering Brackets are not used; otherwise, use with 73-100-550)
73-100-550 Vessel Centering Ring, SR8-Plus (fits into base plate for 1 & 2 L Vessels)
All vessels have volumetric graduation marks and serial numbers except Plastic Vessel p/n 91-030-003.
The AccuCenter SystemThe “AccuCenter” system consists of a specially-designed bracket for the base plate that holds the Super Precision Vessel in place, and may be adjusted for precise vessel centering.
p/n Description
73-101-520 Vessel, USP, Super Precision, 1 L, Glass (requires Vessel Centering Bracket p/n 73-101-519)
73-101-521 Vessel, USP, Super Precision, 1 L, Glass, Amber (requires Vessel Centering Bracket p/n 73-101-519 ;Special Order—min order 6)
73-101-519 Vessel Centering Bracket, AccuCenter (for SR8-Plus with Super Precision Vessels [SPV] 73-101-520/521)
95-590-115 Vessel Centering Bracket, AccuCenter (for Distek dissolution testers with SPV 73-101-520/521)
95-590-119 Vessel Centering Bracket, AccuCenter (for Agilent VK7000 dissolution testers with SPV 73-101-520/521)
Round Bottom Round Bottom, Amber
Flat Bottom Clear Amber Clear Amber
150 mL Vessels 1 L Vessels 2 L Vessels
32 SR8-Plus Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
SR8-Plus Dissolution Test Supplies & Accessories
Vessel CarriersMade of all non-corrosive rigid ABS plastic construction with sturdy non-skid rubber legs, these vessel carriers transport filled vessels to and from media prep stations and dissolution baths. Holds all brands of 1 liter and 2 liter dissolution vessels. Space-saving stackable design when empty. p/n Description
95-590-069 Universal Vessel Carrier, 6 Position
95-590-070 Universal Vessel Carrier, 8 Position
SR8-Plus Vessel Coversp/n Description
73-100-430 ADD (Auto-Dosage Delivery) Vessel Cover for SR8-Plus (manual only)
65-233-170 Low-Evaporation Vessel Cover, Rotary
95-590-046 Low-Evaporation Vessel Cover, Hinged, Clear Acrylic
72-600-587 Slide-Open Vessel Cover (w/ 2 hole plugs)
72-800-430 Vessel Hole Cover
Low-Evaporation Vessel Cover, Hinged
95-590-046
Low-Evaporation Vessel Cover, Rotary65-233-170
ADD Cover for SR8-Plus73-100-430
Slide-Open Vessel Cover72-600-587
Universal Vessel Carrier, 6 Position95-590-069
Universal Vessel Carrier, 8 Position95-590-070
Apparatus TrayMade from sturdy PVC, this compact tray is the safest and most convenient method of storing paddles, basket shafts and baskets. These stackable trays keep the shafts straight and protected while minimizing bench space. Designed to accommodate basket shafts, paddles, and baskets for Vision 2 L, SR8-Plus, and any 15-inch competitor basket shaft and/or paddle. The convenient numbering system also helps keep baskets and shafts organized by position number for ASTM compliance. Protect your investment by protecting the integrity of your apparatus!
p/n Description
74-104-270 Apparatus Tray, Stackable, Vision 2 L, SR8-PlusApparatus Tray 74-104-270
hansonresearch.com | 99-300-001 Rev. 3-14 | SR8-Plus Dissolution Test Supplies & Accessories33
SR8-Plus Dissolution Test Supplies & Accessories
E-Probe Actuator Kits Hanson E-Probes provide electrically actuated sampling probes for Hanson SR8-Plus dissolution testers. E-Probes are mounted directly onto the SR8-Plus drive head (field retrofits available). E-Probe kits provide up/down electronic actuators for each vessel. Head Mount Probes are required for E-Probes and are ordered separately.p/n Description
73-105-106 E-Probe Actuator Kit, 1 L, 6 Sample
73-105-108 E-Probe Actuator Kit, 1 L, 8 Sample
73-105-116 E-Probe Actuator Kit, 2 L, 6 Sample
73-105-118 E-Probe Actuator Kit, 2 L, 8 Sample
Multi-Position E-Probe Option (for programmable height adjustments)The standard 1 liter E-Probe with 1 liter Sample Probe provides the ability to sample from 1000 mL to 500 mL with manual height adjustment. Retrofit your 1 liter E-Probe with a longer 9 in. Lead Screw and 2 liter Sample Probes, and this 1000 mL to 500 mL change is easily programmed on the SR8-Plus.p/n Description
91-220-037 Lead Screw, 9 in. (for E-Probes, Multi-Position Probe; requires 1 for each position)
Digital Temperature ProbesHanson Digital Temperature Probes (DTPs) are rugged and robust digital devices, intelligent in design, and virtually impervious to analog noise. Our exclusive “digital-sensor” technology ensures precision temperature resolution, reporting, and validation and provides extensive data on multiple vessel temperatures, including maximum/minimum/average statistical data. Each Hanson Digital Temperature Probe carries an individual and unique electronic signature, serial number, and calibration log ideal for USP/FDA/21 CFR Part 11 compliancy. Easy retrofit on all Hanson SR8-Plus dissolution testers, DTPs are normally attached to a sampling probe.p/n Description
73-108-100 Digital Temperature Probes (set/6) (factory installed)
73-108-105 Digital Temperature Probes (set/6) (field upgrade kit)
73-108-405 Digital Temperature Probe (1)
Digital Temperature Probes require SR8-Plus firmware ver. 3.10 or higher.
E-Probe Actuator Kit
Digital Temperature Probe (DTP)
Digital Temperature Probe Board
Digital Temperature Probe
34 SR8-Plus Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
SR8-Plus Dissolution Test Supplies & Accessories
Head Mount Sample Probes (for E-Probe Actuator Kits)
p/n Description
60-151-106 Sample Probe Kit, 1 L, 6 Sample, 1/8 in.
60-151-108 Sample Probe Kit, 1 L, 8 Sample, 1/8 in.
60-151-116 Sample Probe Kit, 2 L, 6 Sample, 1/8 in.
60-151-118 Sample Probe Kit, 2 L, 8 Sample, 1/8 in.
73-105-705 Head Kit (set/8) (use with Head Mount Sample Probes without E-Probe Actuators)
Sample Probe Kit• Uses 1/8 in. filters• Use with AutoPlus & E-Probes
Head Kit• Used to mount head mount
sample probes without E-Probe Actuators
If not using E-Probes, order Vessel-Mount Probes, Easi-Probes, or a Head Mount Sample Probe Kit with a Head Kit. Head Mount Easi-Probe Kits are used for manual sampling from the SR8-Plus. Vessel-Mount Probe Kits include vessel covers with stainless sample probes and return probes, tubing connectors, and a wash station (Tubing Harness not included). Order 1 set for each bath. Use of standard tip filters or 5 micron in-line filters are required for sample filtration into the AutoPlus.
Fixed Vessel-Mount Probes (includes covers; requires 3 ft Tubing Harness 600-200-706/708)
p/n Description
60-200-206 Fixed Vessel Sample Probe Kit, 1 L, 6 Sample, 1/16 in.
60-200-208 Fixed Vessel Sample Probe Kit, 1 L, 8 Sample, 1/16 in.
60-200-216 Fixed Vessel Sample Probe Kit, 1 L, 6 Sample, 1/8 in.
60-200-218 Fixed Vessel Sample Probe Kit, 1 L, 8 Sample, 1/8 in.
Easi-Probe Manual Sampling Probes (Head Mount for SR8-Plus only)
p/n Description
72-300-304 Easi-Probe Kit, 1 L, 6 Sample, 1/8 in. (manual sampling)
72-300-305 Easi-Probe Kit, 1 L, 8 Sample, 1/8 in. (manual sampling)
72-300-324 Easi-Probe Kit, 2 L, 6 Sample, 1/8 in. (manual sampling)
72-300-326 Easi-Probe Kit, 2 L, 8 Sample, 1/8 in. (manual sampling)
Fixed Vessel-Mount Sample Probe Kit• Uses 1/8 in. or 1/16 in. filters• Used with AutoPlus• May be used with In-Line Filters
Easi-Probe Kit• Uses 1/8 in. or In-Line Filters• For manual sampling(top)
(bottom)
hansonresearch.com | 99-300-001 Rev. 3-14 | SR8-Plus Dissolution Test Supplies & Accessories35
SR8-Plus Dissolution Test Supplies & Accessories
SR8-Plus Manual Cannula Kitp/n Description
72-300-232 Manual Sampling Cannula Kit (set/8) (includes probes and syringes for Slide-Open Vessel Covers)
316 Stainless Steel Cannulas (with inert Tefzel female luer)1/8 in. o.d. Low hold-up volume. Accommodates in-line filters and/or probe filters.p/n Description
95-590-001 Manual Sampling Cannula, 500 mL, 7.75 in., 316 SS
95-590-002 Manual Sampling Cannula, 900 mL, 4.75 in., 316 SS
95-590-003 Manual Sampling Cannula, Head Mount, 15 in., 316 SS
Sampling Cannulas
PEEK Cannulas (with inert Tefzel female luer) 1/8 in. o.d. PEEK and Tefzel are biocompatible, chemically inert, and non-corrosive. Accommodates in-line filters and/or sample filters. p/n Description
95-590-005 Manual Sampling Cannula, 900 mL, 4.75 in., PEEK
95-590-006 Manual Sampling Cannula, Head Mount, 15 in., PEEK
95-590-007 Stopper for 15 in. Cannula
91-030-132 Syringe, Disposable, Luer Type 10 mL
Fixed Vessel-Mount Sample Probe Kit• Uses 1/8 in. or 1/16 in. filters• Used with AutoPlus• May be used with In-Line Filters
36 SR8-Plus Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
SR8-Plus Dissolution Test Supplies & Accessories
Small Volume—Round Bottom
Tip Sample Filters (100% Porous Polyethylene)This material is 100% inert in all applications and meets all current FDA and USP guidelines. p/n Description
27-101-087 Sample Filters, 1 micron, 1/8 in. (100/pk) (not available 1/16 in.)
27-101-097 Sample Filters, 1 micron, 1/8 in. (1,000/pk) (not available 1/16 in.)
27-101-088 Sample Filters, 4 micron, 1/8 in. (100/pk) (not available 1/16 in.)
27-101-098 Sample Filters, 4 micron, 1/8 in. (1,000/pk) (not available 1/16 in.)
27-101-074 Sample Filters, 10 micron, 1/8 in. (100/pk)
27-101-091 Sample Filters, 10 micron, 1/8 in. (1,000/pk)
27-101-083 Sample Filters, 10 micron, 1/16 in. (100/pk)
27-101-093 Sample Filters, 10 micron, 1/16 in. (1,000/pk)
27-101-085 Sample Filters, 35 micron 1/8 in. (100/pk)
27-101-095 Sample Filters, 35 micron 1/8 in. (1,000/pk)
27-101-086 Sample Filters, 35 micron 1/16 in. (100/pk)
27-101-096 Sample Filters, 35 micron 1/16 in. (1,000/pk)
27-101-089 Sample Filters, 45 micron 1/8 in. (100/pk)
27-101-090 Sample Filters, 45 micron 1/16 in. (100/pk)
27-101-082 Sample Filters, 70 micron, 1/8 in. (100/pk)
27-101-092 Sample Filters, 70 micron, 1/8 in. (1,000/pk)
27-101-084 Sample Filters, 70 micron, 1/16 in. (100/pk)
27-101-094 Sample Filters, 70 micron, 1/16 in. (1,000/pk)
Tip Sample Filters, PVDF (High Purity Porous Polyvinylidene Fluoride)This new material offers lower protein-binding characterisitics to a larger variety of active drug substances. They are 100% inert in all applications and meet all current FDA and USP guidelines. p/n Description
27-101-101 Sample Filters, 10 micron, 1/8 in., PVDF (100/pk)
27-101-102 Sample Filters, 10 micron, 1/8 in., PVDF (1,000/pk)
In-Line Filtersp/n Description
91-450-062 In-Line Filters, 5 micron (75/pk)
72-300-262 In-Line Filter Fitting Kit (8/pk)
Sample Filter• 1, 4, 10, 35, and 70 micron• In packs of 100 or 1,000
In-Line Filter91-450-062
In-Line Filter Fitting Kit72-300-262
In-Line Filter (optional)
91-450-062
hansonresearch.com | 99-300-001 Rev. 3-14 | SR8-Plus Dissolution Test Supplies & Accessories37
SR8-Plus Dissolution Test Supplies & Accessories
SR8-Plus™ Small Volume Kits & Hanson Immersion CellHanson Small Volume accessories are used for low concentration drug formulations and other special applications when small volume dissolution media is required. The 150 mL round-bottom vessel is patterned after the standard USP 1 liter vessel; the flat-bottom vessel is used with the Hanson Immersion Cell. The mini-paddle is patterned after the USP Apparatus 2 paddle. Small Volume Kits for the SR8-Plus include mini-paddle, 150 mL vessel with special vessel cover (choice of round or flat-bottom vessel), and adapter for use on the SR8-Plus vessel plate. Extras may be ordered separately. Small Volume Probe Retrofit Kits (replaces the Sample Probe Kit) are ordered separately (1 per position).
The Hanson Immersion Cell is designed for use with the flat-bottom vessel to eliminate dead volume. The cell uses standard 25 mm filter disks, and its 3 mm deep dosage area provides for testing of infinite dose topical applications. Immersion Cells and convenient assembly tool and grip tool are available in kits; extras may be ordered separately.
p/n Description
72-800-719 Small Volume Dissolution Kit, Round Bottom, 150 mL (1)
72-800-720 Small Volume Dissolution Kit, Round Bottom, 150 mL (set/6)
72-800-721 Small Volume Dissolution Kit, Flat Bottom, 150 mL (1)
72-800-722 Small Volume Dissolution Kit, Flat Bottom, 150 mL (set/6)
74-105-220 Spin-Basket Shaft, Mini (serialized) (Special Order—min. 6) (requires 74-105-221 and 74-205-049)
74-105-221 Basket, Mini, 40 Mesh, 316 SS (serialized) (Special Order—min. 6) (requires 74-105-220 and 74-205-049)
74-205-049 Spindle Shaft (serialized) (Special Order—min. 6) (requires 74-105-220 and 74-105-221)
72-800-714 Vessel Adapter Kit (1 per vessel)
65-190-043 Immersion Cell, 15 mm (cell only)
65-190-051 Immersion Cell, 15 mm (one cell w/ tools)
65-190-052 Immersion Cell, 15 mm (set/6 w/ tools)
72-300-259 Small Volume Probe Retrofit Kit (replaces probe in Sample Probe Kit; order 1 for each vessel)
Small Volume accessories for SR8-Plus and Vision are not interchangeable, except for Immersion Cells.
Round-Bottom Vessel
Mini-Paddle
Vessel Cover
Small Volume—Round Bottom
Flat-Bottom Vessel
Vessel Cover
Small Volume—Flat Bottom
Mini-Paddle
Immersion Cell
Membrane Area
Dosage Area
Immersion Cell(cross section)
38 SR8-Plus Dissolution Test Supplies & Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
SR8-Plus Dissolution Test Supplies & Accessories
Sinkers (for all Hanson dissolution systems)
p/n Description
65-190-012 Sinkers (6/pk) (wt 1.3 g; 9.5 mm x 25 mm capacity)
65-190-013 Sinkers (12/pk) (wt 1.3 g; 9.5 mm x 25 mm capacity)
65-700-316 Stainless Wire to Sink Capsules, 316 SS (50 ft roll)
95-590-021 Sinker, Spiral Coated (0.90 in. x 0.37 in. capacity)
95-590-022 Sinker, Spiral Uncoated, 316 SS (0.90 in. x 0.37 in. capacity)
95-590-023 Sinker, Spiral Coated (1.02 in. x 0.38 in. capacity)
95-590-024 Sinker, Spiral Uncoated (1.02 x 0.38 in. capacity)
95-590-025 Sinker, 3 Prong
95-590-026 Sinker, Japanese Pharmacopoeia Cage
Sprial Coated Sinkers are coated with 100% inert epoxy.
Sinker65-190-012/013
Sprial Coated Sinker95-590-021
Spiral Uncoated Sinker95-590-024
3 Prong Sinker95-590-025
Japanese Pharmacopoeia Cage Sinker95-590-026
Hanson Transdermal Sandwich (USP Apparatus 5 “Paddle Over Disk”)The Transdermal Sandwich is a convenient disk assembly recommended by the FDA for testing patch dosage forms in a standard dissolution test station for USP Apparatus 5 “Paddle Over Disk.” The Transdermal Sandwich consists of a glass watchglass (on which the patch is placed, delivery side up), a 17-mesh PVDF screen (to hold the patch), and PVDF clips to hold the disk assembly together. For use with standard USP 1 liter vessel and paddle. Accommodates patches up to 90 mm diameter. Used on all Hanson dissolution testers.p/n Description
65-190-092 Transdermal Sandwich for Patch
65-190-093 Transdermal Sandwich for Patch (set/6)
Transdermal Sandwich
hansonresearch.com | 99-300-001 Rev. 3-14 | SR8-Plus Dissolution Test Supplies & Accessories39
SR8-Plus Dissolution Test Supplies & Accessories
Accessoriesp/n Description
64-705-722 Air Stone, Soft-Flo, for SR8-Plus (10/pk)
65-233-706 Auto Pill Droppers, 6 Sample (requires E-Probes)
65-233-708 Auto Pill Droppers, 8 Sample (requires E-Probes)
72-800-501 Basket Height Adjustment Spacer, Serialized
72-800-502 Paddle Height Adjustment Spacer, Serialized
91-902-020 Electro-Mechanical Tool Kit
64-700-128 Analog Temperature Probe for SR6-ValiData and SR8-Plus
73-100-714 SR8-Plus 2-Year Spare Parts Kit, 115 V
73-100-715 SR8-Plus 2-Year Spare Parts Kit, 230 V
73-100-700 SR8-Plus Drive Spindle Retrofit Kit (single position)
73-100-719 SR8-Plus Firmware Upgrade Kit ver. 3.11 (compatible with Vision G2 AutoPlus)
64-710-410 Circulating Water Pump—Reverse Plug (since 1997)
64-710-411 Circulating Water Pump—Non-reverse Plug (1995–1996)
Basket & Paddle Spacers72-800-501/502
Air Stone64-705-722
Auto Pill Dropper65-233-706/708
Electro-Mechanical Tool Kit91-902-020
Circulating Water Pump
Volumetric Flasksp/n Description
95-590-041 Volumetric Flask, 500 mL, Class A/20 °C
95-590-042 Volumetric Flask, 900 mL, Class A/20 °C
95-590-043 Volumetric Flask, 1000 mL, Class A/20 °C
95-590-044 Volumetric Flask, 500 mL, Class A/37 °C
95-590-045 Volumetric Flask, 900 mL, Class A/37 °C
Volumetric Flask
hansonresearch.com | 99-300-001 Rev. 3-14 | Legacy AutoPlus Accessories41
Legacy AutoPlus Accessories
40 Legacy AutoPlus Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
Legacy AutoPlus Accessories
Legacy AutoPlus™ AccessoriesThe Hanson AutoPlus autosampler with MultiFill collector has been discontinued (April 2012), although this product will still be supported for several years. The section that follows includes a listing of common accessories and consumables for the legacy AutoPlus and MultiFill. Additional service parts may be available in our current Price Guide.
Legacy AutoPlus Maximizer
AutoPlus Accessoriesp/n Description
60-200-805 Q-Pak IQ/OQ/PQ for AutoPlus
60-200-851 Q-Pak IQ/OQ/PQ for Vision-Enabled AutoPlus
60-200-706 Teflon Tubing Harness, 6 Sample, 3 ft
60-200-708 Teflon Tubing Harness, 8 Sample, 3 ft
60-200-101 Validation Printer for Autosampler, 115 V
60-200-102 Validation Printer for Autosampler, 230 V
47-200-703 Printer Paper Rolls (5/pk)
47-200-704 Printer Ribbon (2/pk)
60-200-700 AutoPlus 2-Year Spare Parts Kit, 115/230 V
91-902-020 Electro-Mechanical Tool Kit
81-200-026 Hanson/Agilent Dissolution Systems Driver ver. 5.0 (on CD)
60-200-724 AutoPlus Firmware ver. 3.20 Upgrade Kit, SR8-Plus
60-200-725 AutoPlus Firmware ver. 4.0 Upgrade Kit, G1 Vision-Enabled AutoPlus (VEAP) (field installed)
Retrieval Reservoir Assembly60-200-022
AutoPlus Retrieval SystemThe AutoPlus Retrieval System is an accessory add-on to the AutoPlus Maximizer that eliminates autosampling waste volume. The “retrieval” accessory returns rinse media back to the vessel after UV analysis and/or collection. Easy field retrofit.p/n Description
60-200-022 Retrieval Reservoir Assembly and Bench Mount Base
PEEK Needle Optionp/n Description
60-200-496 PEEK Needle Kit (field retrofit; replaces stainless steel needles)
hansonresearch.com | 99-300-001 Rev. 3-14 | Legacy AutoPlus Accessories41
Legacy AutoPlus Accessories
AutoPlus MultiFill Collection Racks & AccessoriesMultiFill collector requires 1 collection rack and 1 pack of test tubes or vials to complete installation.p/n Description
91-030-053 Collection Rack for 16 mm x 100 mm Test Tubes
91-030-063 Collection Rack for 12 mm x 32 mm HPLC Vials (pre-cut septum vials required)
91-030-071 Collection Rack for 13 mm x 100 mm Test Tubes
91-030-074 Collection Rack for 1 mL Vials, 192 Position (for Waters WISP 96 carousel, 8 mm x 43 mm)
91-030-051 Test Tubes, 16 mm x 100 mm (250/pk)
27-800-714 Evaporation Caps for 16 mm Test Tubes (50/pk) (pre-cut caps)
91-030-150 HPLC Vials w/ Pre-Cut Septums, 12 mm x 32 mm (100/pk)
27-800-633 Test Tubes, 13 mm x 100 mm (250/pk)
42 Legacy Validation & Calibration Accessories | 99-300-001 Rev. 3-14 | hansonresearch.com
Legacy Validation & Calibration Accessories
legaCy ValiDation & Calibration aCCeSSorieS
Q-Pak™ IQ/OQ/PQ Validation GuidelineThe Hanson Q-Pak addresses manufacturers’ and USP/FDA recommendations for dissolution instrument IQ, OQ, and PQ (Installation, Operation, and Performance Qualifications). This unique guideline directs the user through instrument qualification and documentation of key elements of functional validation. Combined with our easy-to-use calibration tools, the Q-Pak can ensure optimum dissolution performance and maximum regulatory compliance. Q-Paks are ideal guidelines to help develop document system qualification for audit trail.
HRCare provides for U.S. Service and Validation Contracts. See HRCare—Service & Validation Plans for information.
Q-Pak IQ/OQ/PQ Validation Guidelinesp/n Description
73-100-805 Q-Pak IQ/OQ/PQ for SR8-Plus—USP
73-100-876 Q-Pak IQ/OQ for SR8-Plus—ASTM
60-200-805 Q-Pak IQ/OQ/PQ for AutoPlus
60-200-851 Q-Pak IQ/OQ/PQ for Vision-Enabled AutoPlus
58-001-805 Q-Pak IQ/OQ/PQ for MicroettePlus
Printersp/n Description
73-100-116 Validation Printer for SR8-Plus, 115/230 V
60-200-101 Validation Printer for Autosampler, 115 V (AutoPlus or MicroettePlus)
60-200-102 Validation Printer for Autosampler, 230 V (AutoPlus or MicroettePlus)
47-200-703 Printer Paper Rolls (5/pk)
47-200-704 Printer Ribbon (2/pk) Reference & Calibration Accessoriesp/n Description
91-030-000 Handbook of Dissolution Testing, 3rd Edition (by Royal Hanson & Vivian Gray)
91-951-007 USP Calibrator Tabs, Prednisone (30 tabs) (disintegrating)
91-951-017 USP Standard, Prednisone
65-233-000 Shaft Straightening Kit with Dial Indicator
64-700-128 Analog Temperature Probe for SR6-ValiData and SR8-Plus
10-101-601 Air Flow Meter (not certified, for reference only)
91-902-020 Electro-Mechanical Tool Kit
Handbook of Dissolution Testing91-030-000
Table of Contents
73-100-805-F. ©2010 Hanson Research Corp. Page i Usage limited to contractual agreement. Unauthorized duplication is a violation of federal law.
-Functional Validation Guideline 73-100-805-F
Licensed to: Company City/State, Country Serial Number: XXXX-XXXX Q-Pak IQ/OQ/PQ
hansonresearch.com | 99-300-001 Rev. 3-14 | Legacy Validation & Calibration Accessories43
Legacy Validation & Calibration Accessories
Certified Calibrated Tachometer
Digital Thermometer
Alignment Kit
Vibration Meter Kit
Certified Calibrated Digital Thermometer
Certified Vibration Meter KitTypically measures displacement, but may also be used to measure
acceleration and velocity
Tachometer
Certified Alignment KitIncludes Alignment Gauge, Shaft
Wobble Meter, Level, Depth Gauge, and Height Ball Gauge
SR8-Plus Calibration ToolsUsed by HRCare Specialists when performing service and validation on Hanson SR8-Plus dissolution testers and are recommended for in-house validation programs. For more information on these tools, please see SR8-Plus—Tools.p/n Description
65-233-101 Certified Alignment Kit
65-233-203 Certified Vibration Meter Kit
65-233-301 Certified Calibrated Tachometer
65-233-402 Certified Calibrated Digital Thermometer
Certificates & Servicep/n Description
7-920 * Recalibration Service (for items below)
7-909 * Individual Certificate of Conformity for USP Accessory (Special Order)
7-910 * Document Replacement Service for Certificate of Conformity (Special Order)
7-911 * Document Replacement Service for Blank IQ/OQ ProtocolsAvailable to U.S. customers only with proof of related HRCare service purchase
7-912 * Document Replacement Service for Blank PQ Protocols Available to U.S. customers only with proof of related HRCare service purchase
7-930 * Certificate of Analysis for USP Vessel
7-931 * Certificate of Analysis for USP Paddle
7-932 * Certificate of Analysis for USP Basket
7-933 * Certificate of Analysis for USP Basket Shaft
* No discounts apply to p/n 7-XXX. Please supply serial numbers at time of order if applicable.
44 Media-Mate Plus Automatic Prep System | 99-300-001 Rev. 3-14 | hansonresearch.com
Media-Mate Plus Automatic Prep System
Media-Mate Plusp/n Description
25-710-101 Media-Mate Plus, 10–40 L, 115 V
25-710-102 Media-Mate Plus, 10–40 L, 230 V
Media-Mate Plus Accessoriesp/n Description
91-902-045 Calibration Gauge Set (required for fine volume adjustment)
25-710-415 Single Vessel Filler
25-710-705 Calibration KitIncludes:
• 8-Position Universal Vessel Carrier• 8 Plastic Vessels, 1 L• Calibration Gauge Set
25-710-803 Q-Pak IQ/OQ/PQ for Media-Mate Plus
25-710-115 Tank, Heater, and Control, 115 V
25-710-116 Tank, Heater, and Control, 230 V
25-710-723 Filter Sediment Cartridge, Polypropylene, 5 micron (5/pk)
11-000-004 Media Filler Hose Extension with Filter (draws media from other source)
25-710-113 Dispense Bar for Sotax AT7
25-710-125 Temperature Control Only, 115 V
25-710-126 Temperature Control Only, 230 V
25-710-442 Low Volume Tank Assembly
25-710-130 Heater Assembly Only, 115 V
25-710-131 Heater Assembly Only, 230 V
25-710-701 Media-Mate Plus 2-Year Spare Parts Kit, 115/230 V
91-902-020 Electro-Mechanical Tool Kit
Media-Mate Plus(includes Tank, Heater, and Control)
Media-Mate Plus™ Automatic Prep SystemThe Hanson Media-Mate Plus delivers pre-heated, filtered, deaerated, volumetrically dispensed media to six or seven dissolution vessels in less than five minutes, and it has been updated (Oct 2012) to provide improved performance in deaeration (dissolved oxygen now below 6 ppm) and reduced unusable volume in the media tank (from 8 to 2 L). Built on a unique ergonomic cart, the Media-Mate Plus offers maximum portability for easy servicing of many dissolution test stations.
Interchangeable pre-heat tanks accommodate 10-40 L media and buffers with precision temperature control. Delivery volume is adjustable 250 to 1,000 mL in 50 mL increments. Media deaeration is below 95% saturation when delivered to dissolution vessels (deaeration is achieved using thin film treatment in a vacuum). The convenient dispense bar fills 3+3, 4+2 or 4+3 vessel layouts. A special dispense bar is available for the Sotax AT7 tester.
Performance upgrade kits are available for existing Media-Mate Plus units.
Tank, Heater, and Control
hansonresearch.com | 99-300-001 Rev. 3-14 | Media-Mate Plus Automatic Prep System45
Media-Mate Plus Automatic Prep System
Upgrade Kitsp/n Description
25-710-731 Low Volume Tank Upgrade Kit, Media-Mate Plus
25-710-733 Fill Tube Upgrade Kit, Media-Mate Plus
New operational panel provides easy-to-use controls. One simple button initiates complete media measurement/deaeration/dispense cycle. Fills the dissolution bath in less than 5 minutes.
New volume change adjustments provide quick and easy volume settings from 250 mL to 1,000 mL in 50 mL increments. Fill 6 or 7 vessels in Hanson, Agilent, VanKel, Distek, Erweka or other dissolution testers.
46 Diffusion Cell Test Systems | 99-300-001 Rev. 3-14 | hansonresearch.com
Diffusion Cell Test Systems
DiffuSion Cell teSt SyStemS
6-Cell Manual Test SystemA start-up vertical diffusion cell test system for manual use and sampling. This expanded package includes a 6-cell drive system with stainless stand, 6 vertical diffusion cells (see choices below), convenient manual sampling syringe, jacketed media replace beaker, and supply kit. The circulating waterbath must be ordered separately. The start-up manual test system is adaptable for later addition of the new Vision Microette autosampler. Please specify voltage when ordering. See USP <1724> for further information.
6-Cell Manual Test System (58-6M) - Including Cells
58-6M System with: p/n with Clear Cells p/n with Amber Cells
4 mL Cells, “Small” 58-001-401 58-001-411
7 mL Cells, “Standard” (FDA-recommended for topicals)
58-001-402 58-001-412
12 mL Cells, “Large” 58-001-403 58-001-413
Circulating Waterbath System & Accessoriesp/n Description
58-001-430 Programmable Circulating Waterbath, 115 V (recommended)
58-001-431 Programmable Circulating Waterbath, 230 V (recommended)
58-001-721 Start-up Tool Kit, 115 V (recommended)Includes vacuum pump, service vessel assembly, and applicator
58-001-722 Start-up Tool Kit, 230 V (recommended) Includes vacuum pump, service vessel assembly, and applicator
91-030-138 Applicator/Mixer, Polyethylene
91-030-155 Manual Sampling Syringe
91-030-150 HPLC Vials w/ Pre-Cut Septums, 12 mm x 32 mm (100/pk) (recommended)
58-001-716 Check Valves (100/pk) (recommended)
58-001-815 Q-Pak IQ/OQ/PQ for Manual Diffusion Cell System (recommended)
91-030-062 Membrane for Cells, 25 mm dia x 0.45 micron (100/pk) (recommended)
Please specify choice of Vertical Diffusion Cells when ordering:
6-Cell Manual Test System(pictured with recommended circulating bath option; manual sampling syringe not shown)
hansonresearch.com | 99-300-001 Rev. 3-14 | Diffusion Cell Test Systems47
Diffusion Cell Test Systems
Vision® Microette™ Automated Test SystemThe Vision Microette (2014) is a modern update of the popular Hanson MicroettePlus (introduced in 2001), including all the feature and performance characteristics of its predecessor, and more. The system provides precise automatic sampling from topical Vertical Diffusion Cells and collection into HPLC or UPLC vials for sample analysis. For reference, see USFDA Guideline SUPAC-SS, and USP <1724> Semisolid Drug Products – Performance Tests.
The Vision Microette system automates sampling from groups of 6 Vertical Diffusion Cells for extensive unattended tests, and handles surfactants, saline, and hydroalcoholic receptor solutions. The Microette is an ideal research and quality control tool for the study of topical and transdermal drug delivery formulations, as well as ophthalmics, cosmetics, skin care products, and pesticides.
The Vision Microette now includes two models: a versatile “multi-group” system handling up to 3 sets of Vertical Diffusion Cells (VDCs), and a lower cost “single-group” system automating 1 set of VDCs. Both models incorporate Hanson “AutoPlus” technology, and include a precision 6-channel syringe pump, PEEK valves and inert sample tubing, user-friendly programming with touchscreen graphical display, up to 100 test protocols, ComSwitch for system communications, automatic media replace at time of sampling, jacketed media replace beaker, cell volume evaluation kit, and supply kit. AutoFill Collector, Vertical Diffusion Cells, and Cell Drive systems must be ordered with each system; Circulating Waterbath and other accessories are available as options. US Patents, CE, CSA and RoHS compliant.
Vision Microette Autosampler
Vision Microette Autosamplerp/n Description
59-101-002 Vision Microette Autosampler, Multi-Group
59-101-003 Vision Microette Autosampler, Single-Group
AutoFill Collectorp/n Description
61-201-001 AutoFill Collector, 115/230 V
61-201-053 Rack, Collector, for 12 mm x 32 mm HPLC Vials
61-201-054 Rack, Collector, for 12 mm x 32 mm UPLC Vials (For Waters Acquity UPLC System; requires Upgrade Kit 61-201-015 and 3 UPLC Vial Trays 91-030-159)
61-201-015 Upgrade Kit, AutoFill for UPLC Rack (required for p/n 61-201-054 UPLC Rack)
91-030-159 Vial Tray, 48 Well for 2 mL UPLC Vials (requires 3 trays per p/n 61-201-054 UPLC Rack)
91-030-150 Vials w/ Pre-Cut Septums, HPLC/UPLC, 12 mm x 32 mm (100/pk) AutoFill Collector
Cell Drive System (required with system)Includes precision electronic 2mag (formerly Variomag) 6-Cell Drive System with control and stainless stand.p/n Description
58-001-420 6-Cell Drive System for Vision Microette (1 per group)
Circulating Waterbath System (recommended with system)
p/n Description
58-001-430 Programmable Circulating Waterbath, 115 V (for up to 3 groups)
58-001-431 Programmable Circulating Waterbath, 230 V (for up to 3 groups)
48 Diffusion Cell Test Systems | 99-300-001 Rev. 3-14 | hansonresearch.com
Diffusion Cell Test Systems
Vision Microette Single-Group vs. Multi-Group The Vision Microette now includes two models: a versatile “multi-group” system handling up to 3 sets of Vertical Diffusion Cells, and a lower cost “single-group” system automating 1 set of VDCs. The Vision Microette Multi-Group autosampler can be expanded to handle up to 3 groups of cell experiments for a total of 18 cells (6 cells per group). To expand the system, each group requres an additional 6-cell drive, cells, and AutoFill.
Vision Microette Multi-Group Expansion Kitp/n Description
58-001-720 Multi-Group Expansion Kit (order 1 per additional 6-cell group)
Vision Microette Automated Test System—Single-Group Setup—automates sampling from 1 group of 6 diffusion cells.
Vision Microette Multi-Group Setup—18 Cells—automates sampling from 3 groups of 6 diffusion cells (18 total).
Vision Microette Multi-Group Setup—12 Cells—automates sampling from 2 groups of 6 diffusion cells (12 total).
hansonresearch.com | 99-300-001 Rev. 3-14 | Diffusion Cell Test Systems49
Diffusion Cell Test Systems
Vertical Diffusion Cells (required with system)Precision vertical diffusion cells designed for ease of use and accuracy. Complete cell assemblies include receptor chamber and clamp, dosage wafer (300 mg “infinite dose”), sampling and media replace ports, outside jacket for temperature control, and Helix stirrer. Each cell includes an individual serial number; volumes listed are nominal value. Ordering 1 extra cell with each group of 6 is strongly recommended. Please consult Hanson for special cell requirements. See USP <1724> for further information.
Vertical Diffusion Cellsp/n Description
58-001-451 Vertical Diffusion Cell, 9 mm Orifice, 4 mL vol, “Small”
58-001-455 Vertical Diffusion Cell, 15 mm Orifice, 7 mL vol, “Standard” (recommended by FDA for topicals)
58-001-459 Vertical Diffusion Cell, 15 mm Orifice, 12 mL vol, “Large”
58-001-452 Vertical Diffusion Cell, 9 mm Orifice, 4 mL vol, Amber, “Small”
58-001-456 Vertical Diffusion Cell, 15 mm Orifice, 7 mL vol, Amber, “Standard” (recommended by FDA for topicals)
58-001-460 Vertical Diffusion Cell, 15 mm Orifice, 12 mL vol, Amber, “Large”
For Cell Type
Description 4 mL 7 mL 12 mL
Complete Clear Cell with Std Top, Clamp, and Helix
58-001-451 58-001-455 58-001-459
Complete Amber Cell with Std Top, Clamp, and Helix
58-001-452 58-001-456 58-001-460
Clear Vertical Diffusion Cell 58-001-453 58-001-457 58-001-461
Amber Vertical Diffusion Cell 58-001-454 58-001-458 58-001-462
Clamp Assembly 58-001-450 58-001-450 58-001-450
Helix Kit 58-001-467 58-001-467 58-001-468
For Cell Type
DIM 4 mL 7 mL 12 mL
A Ø38 mm Ø38 mm Ø38 mm
B Ø9 mm Ø15 mm Ø15 mm
C Ø9 mm Ø9 mm Ø15 mm
D Ø30 mm Ø30 mm Ø30 mm
E 61 mm 61 mm 61 mm
Clamp Assembly
A
B
DC
E
Vertical Diffusion Cell
Helix
50 Diffusion Cell Test Systems | 99-300-001 Rev. 3-14 | hansonresearch.com
Diffusion Cell Test Systems
Standard Cell Tops (included with cell)This top style is included with the complete cell assembly. It is occluded to minimize back diffusion during the sampling process. It is suggested to use this top style when testing more viscose materials, such as creams, gels, and ointments. Other dosage wafers available.
For Cell Type
Description 4 mL 7 mL 12 mL
Cell Ring 58-001-507 58-001-507 58-001-507
Glass Disk 58-001-506 58-001-506 58-001-506
Dosage Wafer 501-001-518 58-001-521 58-001-521
For Cell Type
DIM 4 mL 7 mL 12 mL
A Ø38 mm Ø38 mm Ø38 mm
B Ø9 mm Ø15 mm Ø15 mm
C 4 mm 4 mm 4 mm
D 1.5 mm 1.5 mm 1.5 mm
Open Cell Tops with Caps (sold separately, cell not included)This Open Cell Top style is easily adaptable to the Vertical Diffusion Cell. It is typically used for less viscose donor material. The cap can be removed between sampling time points to add or remove material.p/n Description
58-001-530 Open Cell Top w/ Cap, 9 mm, Glass (2 mL capacity)
58-001-548 Open Cell Top w/ Cap, 9 mm, Glass, Amber (2 mL capacity)
58-001-531 Open Cell Top w/ Cap, 15 mm, Glass (6 mL capacity)
58-001-549 Open Cell Top w/ Cap, 15 mm, Glass, Amber (6 mL capacity)
For Cell Type
Description 4 mL 7 mL 12 mL
Threaded Cell Top 58-001-530 58-001-531 58-001-531
Amber Threaded Cell Top 58-001-548 58-001-549 58-001-549
For Cell Type
DIM 4 mL 7 mL 12 mL
A Ø38 mm Ø38 mm Ø38 mm
B Ø9 mm Ø15 mm Ø15 mm
C Ø9 mm Ø18 mm Ø18 mm
D Ø12 mm Ø22 mm Ø22 mm
E 6 mm 6 mm 6 mm
F 30 mm 30 mm 30 mm
Seal
Cap
15 mm Threaded Cell Top
Membrane
Vertical Diffusion Cell(not included)
D
C
BA
F
E
Thre
aded
Cell
Top
Cell Ring
Glass Disk
Dosage Wafer
Membrane
Vertical Diffusion Cell
Stan
dard
Cell
Top
A
BD
C
hansonresearch.com | 99-300-001 Rev. 3-14 | Diffusion Cell Test Systems51
Diffusion Cell Test Systems
Cell Accessories & Spare Partsp/n Description
58-001-450 Clamp Assembly
58-001-453 Vertical Diffusion Cell, 4 mL, Clear (cell only)
58-001-454 Vertical Diffusion Cell, 4 mL, Amber (cell only)
58-001-457 Vertical Diffusion Cell, 7 mL, Clear (cell only)
58-001-458 Vertical Diffusion Cell, 7 mL, Amber (cell only)
58-001-461 Vertical Diffusion Cell, 12 mL, Clear (cell only)
58-001-462 Vertical Diffusion Cell, 12 mL, Amber (cell only)
58-001-467 Helix Cell Kit, 9 mm (for 4 mL & 7 mL cell)
58-001-468 Helix Cell Kit, 15 mm (for 12 mL cell)
58-001-506 Glass Cell Disk
58-001-507 Cell Ring
58-001-518 Dosage Wafer, 9 mm (for 4 mL cell)
58-001-521 Dosage Wafer, 15 mm (for 7 mL & 12 mL cells)
58-001-556 Dosage Wafer, Double Thick, 9 mm x 3.0 mm (for 4 mL cell)
58-001-551 Dosage Wafer, Double Thick, 15 mm x 3.0 mm (for 7 mL & 12 mL cells)
58-001-529 PVC Cell Top w/ ¼-28 Port (fits both 9 mm & 15 mm cells)
Printersp/n Description
60-200-101 Validation Printer for Autosampler, 115 V (recommended)
60-200-102 Validation Printer for Autosampler, 230 V (recommended)
47-200-703 Printer Paper Rolls (5/pk) (recommended)
47-200-704 Printer Ribbon (2/pk) (recommended)
Accessories & Spare Partsp/n Description
58-001-721 Start-up Tool Kit, 115 V (recommended) Includes vacuum pump, service vessel assembly, and applicator
58-001-722 Start-up Tool Kit, 230 V (recommended)Includes vacuum pump, service vessel assembly, and applicator
58-001-815 Q-Pak IQ/OQ/PQ for Manual Diffusion Cell System
59-108-005 Q-Pak IQ/OQ/PQ for Vision Microette (recommended)
91-030-062 Membranes, 25 mm diam, 0.45 micron (100/pk) (recommended)
91-030-138 Applicator/Mixer, Polyethylene
91-902-020 Electro-Mechanical Tool Kit
59-107-011 Needle Cleaning Adapter Kit, 6/pk, Vision Microette and MicroettePlus (recommended spare)
59-107-012 Cell Cleaning Adapter Kit, Vision Microette and MicroettePlus (recommended spare)
Validation Printer
Vertical Diffusion Cell
52 Diffusion Cell Test Systems | 99-300-001 Rev. 3-14 | hansonresearch.com
Diffusion Cell Test Systems
Fiber Optic Diffusion Cell
F/O Probe (sold separately)
Cell 15 mm
Helix Kit
Nail Holder Diffusion Cell Top
Cell not included
Nail
Patch Support Top
Special Application Cells & Cell Tops (Special Order)
p/n Description
58-001-471 Diffusion Cell Top—Finger/Toenail Holder, 10 mm, PEEK (cell not included; min order 6)
58-001-472 Fiber Optic Diffusion Cell, 15 mm (F/O probe not included, min order 6)
58-001-473 Fiber Optic Diffusion Cell, 15 mm, Amber (F/O probe not included, min order 6)
58-001-707 Iontophoresis Cell Top Kit, 9 mm (set/6) (for 4 mL cell; cell not included)
58-001-708 Iontophoresis Cell Top Kit, 15 mm (set/6) (for 7 mL & 12 mL cell; cell not included)
58-001-571 Patch Support (replaces Glass Cell Disk and Wafer to allow for air circulation at top of patch)
Iontophoresis Cell Top Diagram
hansonresearch.com | 99-300-001 Rev. 3-14 | Physical Test Equipment53
Physical Test Equipment
Flodex™ Powder Flowability Test ApparatusThe Flodex Test Apparatus is ideal for determining the intrinsic flowability of powders. Recommended for quality control of powders used in pharmaceutical production and other industrial processes. The Flodex instrument includes 1 complete set of 19 index flow disks. U.S. Patent. CE Approved.
Flodexp/n Description
21-101-050 Flodex Test Apparatus—Complete
21-101-055 Index Flow Disks Flodex Test Apparatus
QC-21 2-Basket Test System
pHySiCal teSt equipment
Legacy QC-21™ Disintegration Test SuppliesThe Hanson legacy QC-21 Disintegration Test System has been discontinued (September 2011), although this product will still be supported for several years. The section that follows includes a listing of common accessories for the legacy QC-21 unit. Additional service parts and accessories may be available in our current Price Guide.
Disintegration Test Accessories & Spare Partsp/n Description
65-320-001 USP Standard Disintegration Basket Assembly (App. A)
65-303-011 Veterinary Bolus Disintegration Basket Assembly (App. B)
39-400-810 IQ/OQ—Qualification Protocol for QC-21
91-030-036 Beaker, 1 L
65-170-001 Plastic Disks for Standard Basket (set/6) (App. A)
65-303-023 Plastic Disks for Veterinary Basket (set/3) (App. B)
65-169-001 Glass Tubes for Standard Basket (set/6) (App. A)
65-303-022 Glass Tubes for Veterinary Basket (set/3) (App. B)
65-320-010 Top Plate (assembly w/ 10 mesh screen) (Special Order)
39-400-805 QC-21 2-Year Spare Parts Kit, 115 V
39-400-807 QC-21 2-Year Spare Parts Kit, 230 V
91-902-020 Electro-Mechanical Tool Kit
54 HRCare | 99-300-001 Rev. 3-14 | hansonresearch.com
HRCare
HrCare™
Service & Validation PlansAt Hanson, we care about quality! We build our equipment to last ten years and longer, and we want our customers to earn return after return on their investment. Hanson HRCare support programs maintain your dissolution test systems in tiptop shape for years of service, performance, and laboratory throughput.
HRCare service, maintenance, installation, and validation programs are designed to bring you the confidence of “audit-proof” dissolution lab validation. We support every maintenance, calibration, and validation protocol with ISO 9001:2008 quality documentation. HRCare programs are available to all U.S. customers. Similar programs are available in select countries worldwide—please consult Hanson for details.
HRCare service technicians are factory trained and updated on the latest product technology, software/firmware, and regulatory developments.
hansonresearch.com | 99-300-001 Rev. 3-14 | HRCare55
HRCare
ASTM ProgramHanson HRCare provides ASTM E2503-13 mechanical qualification, in addition to comprehensive IQ/OQ/PQ, service, and extended warranty programs. HRCare ASTM mechanical qualification is available for Hanson SR8-Plus and Vision dissolution testers, including older units already installed and in use. A suitable PM program is recommended for all older equipment. The Hanson HRCare team is factory-trained and certified on all aspects of instrument qualification, service, and preventive maintenance.
Hanson ASTM Certificates of Conformity (COCs) are available for USP accessories (vessels, paddles, baskets, and shafts), detailing all relevant ASTM dimensions and tolerances. These quality accessories, with corresponding COCs, are required for ASTM. Certificates of Analysis (COAs), recording actual dimensional measurements, are available for USP accessories on special order (please note that a COA is not required for ASTM when a COC is available). A convenient “pre-scan” to evaluate previously installed equipment is available prior to full ASTM mechanical qualification.
Design Qualification DQs (Design Qualification documents) are available upon customer request for Hanson equipment. Please consult Hanson for details.
HRCare Service Technicians
Hanson Research Corp. hereby certifies that this product was designed, evaluated, validated, inspected, and tested to approved specified quality requirements of Hanson Research Corp. in conformance with current USP <711>, EP (2.9.3), JP (6.10), and ASTM E2503-07 specifications.
The following standards regarding quality assurance requirements were used for this quality analysis:
1. ISO 9001:2008 clause 8.2.4 Monitoring and Measurement of Product
2. ANSI Z1.9 Sampling Procedures and Tables for Inspection by Variables
3. ANSI Z540-1 part 2 Quality Assurance Requirements for Measuring and Test Equipment
9810 Variel Avenue • Chatsworth, CA 91311 USA 800.821.8165 • 818.882.7266 • Fax 818.882.9470 74-108-132 Rev. 9-12
Product Name Precision Basket, 40 Mesh, 316 SS Part Number 74-105-252
Serial Number(s):
1 5 9 2 6 10 3 7 11 4 8 12
Material ........................................... 316 Stainless Steel A. Overall Height ......................................... 37.0 ± 3.0 mm B. Open Screen Height ............................... 27.0 ± 1.0 mm C. Flange Outside Diameter ........................... 25 ± 3.0 mm D. Screen Outside Diameter ....................... 22.2 ± 1.0 mm E. Top Flange Inside Diameter ................... 20.2 ± 1.0 mm F. Bottom Screen Diameter......................... 20.2 ± 1.0 mm G. Wire Diameter ......................................... 0.250.31 mm H. Wire Opening .......................................... 0.360.44 mm I. Runout ..................................................... TIR < 1.0 mm
November 20, 2012
Basket COC
ASTM Certificate of Conformity (COC) and Certificate of Analysis (COA)Hanson USP accessories (vessels, paddles, baskets, and shafts) are available with ASTM Certificates of Conformity (COCs) at time of order. COCs for individual accessories are available on special order. “Range” COCs are available on the Hanson Web site. ASTM Certificates of Analysis (COAs), recording actual dimensional measurements, are available by Special Order (minimum order 6).
p/n Description
7-909 * Individual Certificate of Conformity (COC) for USP Accessory (Special Order)
7-910 * Document Replacement Service for Certificate of Conformity (COC) (Special Order)
7-930 * Certificate of Analysis (COA) for USP Vessel
7-931 * Certificate of Analysis (COA) for USP Paddle
7-932 * Certificate of Analysis (COA) for USP Basket
7-933 * Certificate of Analysis (COA) for USP Basket Shaft
* No discounts apply to p/n 7-XXX. Please supply serial numbers at time of order, if applicable.
56 Terms, Conditions, and Warranty | 99-300-001 Rev. 3-14 | hansonresearch.com
termS, ConDitionS, anD Warranty
PAYMENT TERMS:All banking charges are for buyer’s account. Those charges should be accounted for prior to payment so that Hanson receives the full amount shown on invoice. Banking charges for letters or credit are buyer’s responsibility.Domestic: Prepayment or Net 30 days for established accounts subject to approved credit limit (unless otherwise specified on quotation). Prepayment for new accounts, until credit is granted.International: Prepayment or confirmed irrevocable Letter of Credit, payable at sight in U.S. dollars (unless otherwise specified on quotation). Hanson Research Corporation’s (HRC’s) banking information will be provided at time of order confirmation. Any other payment arrangements may only be made with approval by CEO or CFO. Payment terms may not be changed after order confirmation is accepted without approval by CEO or CFO.
Payments may be made via wire transfer, credit card or check.• For wire transfers, HRC’s banking information is available upon request.• For credit cards, HRC accepts Visa, MasterCard, or American Express. Please provide the account number, expiration date, security code
and complete cardholder name as shown on card account. Cardholder’s billing address must also be provided.• For checks, make all checks payable to: Hanson Research Corporation, 9810 Variel Avenue, Chatsworth, CA 91311, payable in U.S. dollars
only.
SHIPMENT TERMS: Domestic: Orders will be invoiced as “Prepay and Add” shipments via an HRC contracted carrier, unless otherwise specified on purchase order.International: Orders will be shipped on an Ex-Works, Chatsworth, CA-Freight Collect basis, unless otherwise agreed upon. All shipping terms & carrier selection will be confirmed by a written HRC confirmation, based on an accepted purchase order. When carrier is not specified on purchase order or prior to shipment, HRC reserves the right to use a contracted carrier. Any shipments paid for as CAD must be shipped via HRC contracted carrier with buyer responsible for all charges. SHIPMENTS: HRC assumes no responsibility for delay or damage of goods after delivery to carrier for all Ex-Works and Collect shipments. For “Prepay and Add” or CIF shipments, all damage claims must be reported within 5 calendar days of receipt to both HRC and the carrier. All damage claims not reported within the 5 calendar day period will not be reviewed or accepted. HRC will render all possible assistance in securing satisfactory adjustment for claims accepted by carrier.
DELIVERY: The estimated delivery date quoted is our best approximation of order shipment. HRC assumes no liability for loss, general damages, or special or consequential damages due to delays.
CANCELLATIONS & RETURNED GOODS: Cancellations and return of goods are accepted only at the sole discretion of HRC. In the event that buyer cancels delivery of any product purchased hereby prior to the date of shipment, buyer agrees to pay HRC, in addition to any costs and expenses incurred by us in connection with this order, a 10% (ten percent) cancellation charge. After shipment, buyer agrees to obtain written authorization from HRC for any return. If return of goods is authorized, buyer agrees to pay HRC, in addition to any costs and expenses incurred by us in connection with this order, all transportation charges and a restocking charge not to exceed 25% (twenty-five percent.) The return of custom or special items will not be permitted.
GENERAL WARRANTY: HRC products are warranted for one full year including parts and labor. Service contracts and Preventive Maintenance contracts are available for post-warranty support. International dealer warranties may vary. HRC makes no warranty, expressed or implied, for glassware, consumables, or products not manufactured by HRC, as evidenced by nameplate on the item or other designation. HRC will give responsible assistance to buyer in obtaining from the respective manufacturer whatever adjustment is reasonable in light of manufacturer’s own warranty. HRC shall be released from any and all obligations under any warranty, either expressed or implied, if the product covered is repaired or modified by other than its own personnel, or made without written authorization from HRC. There are no other warranties, expressed or implied, and HRC shall not be liable under any circumstances for consequential damages.
FORCE MAJEURE: The parties to this agreement shall not be held liable in damages or have the right to terminate this agreement for failure or delay in the performance of any of its terms as a result of conditions beyond their control, such as--but not limited to--war, strikes, fires, floods, acts of God, governmental restrictions, power failures, or damage or destruction of any network facilities or servers.
APPLICABLE LAW: This agreement is made and entered into in the State of California, U.S.A., and shall be governed by its laws.
ENTIRE TERMS, CONDITIONS & WARRANTY: These terms, conditions and warranty constitute the entire terms, conditions and warranty as to their subject matter and supersede all prior and contemporaneous oral and written agreements.
HRC / Effective March 1, 2011
hansonresearch.com | 99-300-001 Rev. 3-14 | Packaging Information57
Notes:
• lb x .4536 = kilograms• cm x .3937 = inches• EIN # 95-2386931• Sched. B. # for Systems: 9027.80.3500• Sched. B. # for Accessories: 9027.90.8950
• Harmonized Tariff #: 9027-80-8030
• Courier shipment rates are based on volume, NOT weight.• U.S. Post Office will not accept packages larger than 79 in. total (length x girth).• Damage Claims must be made within 5 days of receipt of goods. Claims made after 5th day will not be accepted unless
carrier agrees to claim.• Order Cancellation Fee: 10% of order.• Restocking Fee: Up to 25% on returned goods.• No returns accepted on custom or special orders.
paCkaging information
System PiecesWeight
(lb)Weight
(kg)Box/Pallet
Dimensions (in.)Box/Pallet
Dimensions (cm)
Vision Classic 6 1 150 68 41 x 37 x 39 104 x 94 x 99
Vision Elite 8 1 215 98 41 x 37 x 44 104 x 94 x 112
Vision G2 AutoPlus & AutoFill 1 165 75 49 x 41 x 30 125 x 104 x 76
Vision AutoFilter Changer 1 100 46 41 x 37 x 24 104 x 96 x 61
Vision Microette & AutoFill 1 230 105 49 x 41 x 46 125 x 104 x 117
Manual Diffusion Cell System 1 53 25 24 x 20 x 33 61 x 51 x 84
Media-Mate Plus 1 210 95 41 x 37 x 59 104 x 94 x 150
Flodex 1 11 5 24 x 10 x 10 61 x 25 x 25
Alignment Kit 1 8 4 15 x 12 x 10 38 x 31 x 25
Validation Tool Kit 1 12 6 18 x 16 x 12 46 x 41 x 31
Certified Vibration Meter Kit 1 8 4 15 x 12 x 10 38 x 31 x 25
Vessels, 1 L, Glass, SR8-Plus (6 pc.) 1 8 4 18 x 16 x 12 46 x 41 x 31
Vessels, Easi-Lock, 1 L, Glass, Vision (6 pc.)
1 10 5 18 x 16 x 12 46 x 41 x 31
Printer 1 8 4 18 x 16 x 12 46 x 41 x 31
Extra Tank, Heater and Controlfor Media-Mate Plus
1 30 14 26 x 20 x 36 66 x 51 x 91
Refurbished Units PiecesWeight
(lb)Weight
(kg)Box/Pallet
Dimensions (in.)Box/Pallet
Dimensions (cm)
SR8-Plus 2 260 119
Box #1 70 32 26 x 21 x 37 66 x 53 x 94
Box #2 190 87 41 x 49 x 48 104 x 125 x 122
Legacy AutoPlus & MultiFill 1 165 75 41 x 49 x 48 104 x 125 x 122
58 Trademarks & Notices | 99-300-001 Rev. 3-14 | hansonresearch.com
traDemarkS
HANSON TRADEMARKS HEREIN
Vision® is a registered trademark of Hanson Research Corp.
The following are trademarks of Hanson Research Corp.:
Technology for Humanity, Quality • Technology • Science, Classic 6, Elite 8, AutoMag, SuperMag, Easi-Lock, ADD, HRCare, AutoPlus, Maximizer, DissoScan, Easy-Icon, Auto-Archive, SR8-Plus, Q-Pak, Easi-Lift, Soft-Flo, E-Probe, Easi-Probe, Auto-Probe, Transdermal Sandwich, Media-Mate Plus, QC-21, Flodex, MicroettePlus, Helix, AutoFill, AutoFilter, Microette
OTHER TRADEMARKS HEREIN
ChemStation is a trademark of Agilent Technologies, Inc.
Empower, Alliance, and UPLC are registered trademarks of Waters Corporation.
MultiFill is a trademark of SOTAX.
Kynar is a registered trademark of Arkema, Inc.
Teflon and Tefzel are registered trademarks of E. I. du Pont de Nemours and Company.
notiCeS
The products and services in this Buyer’s Guide are periodically updated, and Hanson reserves the right to make additions or refinements at any time.
Some images may not be to scale, and some colors may vary from actual products.
Materials: Hanson uses the highest quality materials and components in its design and manufacture of laboratory instruments. Critical wetted surfaces are typically borosilicate glass, quality 316 stainless steel, Teflon (or equivalent PTFE), Kynar (or equivalent PVDF), Tefzel (or equivalent ETFE), and/or PEEK. See instrument User Guides or visit our website (www.hansonresearch.com) for complete specifications.
Special Orders are not stock items. Lead time varies. Minimum order quantities apply. No refunds, returns or exchanges.
hansonresearch.com | 99-300-001 Rev. 3-14 | Notes59
noteS
about HanSon
Our Logo, Our SpiritHanson Research has over 60 years of experience in the dissolution industry with humble beginnings as a small, family company. Although we continue to reinvent ourselves, our products, and our company, we still carry with us the importance of family and embrace this belief with our employees, partners, and customers.
The sweeping “Hanson curve” of our logo, first used in our instrument design in the 1990s, embodies the spirit and vision of Hanson. It reflects the profile of a dissolution vessel as well as the curve of the globe, both of which are fundamental aspects of our international company. It also represents the road to the future, the trail of a rocket blazing into space, and a sailboat journeying across the oceans. Honoring our traditions, we continue to use orange as our company color to celebrate our founder Bill Hanson, whose favorite color was orange. Our accompanying tag line “Quality • Technology • Science” asserts our corporate commitment to the pharmaceutical, life sciences, and healthcare industries worldwide.
This is the history of our logo and the essence of our spirit. This is Hanson Vision.
Technology for HumanityHanson Vision products are not only designed and manufactured with the highest standards of quality and technology, but they are also earth-friendly. All Vision equipment is RoHS (Reduction of Hazardous Substances) and WEEE (Waste Electrical and Electronic Equipment) compliant. We have diligently designed out heavy metals that are harmful to the environment and are introducing new biodegradable and recyclable packaging. At our design and manufacturing site in California, we have converted over 50% of our waste to recycle programs and continuously improve this effort. We use paper with recycled content and soy-based ink for our printed materials and are moving towards a paperless office. We at Hanson consider ourselves citizens of the planet and are committed to creating clean Technology for Humanity.
Made in CaliforniaHanson Research is headquartered in Southern California, USA, home of a growing technology, research, and biotech sector. Our outdoor California lifestyle, epitomized by “sun and surf,” is reflected in our user-friendly, elegant, and ergonomic industrial design, as well as our cutting-edge technology and digital communications. Although we dress casually at the office, we are well-suited and committed to improving the quality assurance of medicine and healthcare worldwide.
Around the WorldHanson Research equipment is running in manufacturing laboratories, universities, regulatory
agencies, and testing facilities around the world. With over 55 international sales and service representatives, Hanson is truly an international company. We continue to expand our network of service and support to even the most remote locations. To see a current list of our worldwide locations, please visit hansonresearch.com.
Hanson Research Corporation9810 Variel AvenueChatsworth, CA 91311 USA800.821.8165818.882.7266818.882.9470 faxhansonresearch.com
©2014 Hanson Research Corp. ● CA, USA ● 800.821.8165 ● 818.882.7266 ● 818.882.9470 fax ● hansonresearch.com ● 99-300-001 Rev. 3-14