hampton university and jefferson lab virginia, usa
DESCRIPTION
JPOS09: Int. Workshop on Positrons at Jefferson Lab, March 25-27, 2009. OLYMPUS @ DESY A proposal to definitively determine the contribution of multiple photon exchange in elastic lepton-nucleon scattering. Michael Kohl. Hampton University and Jefferson Lab Virginia, USA. Overview. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/1.jpg)
OLYMPUS @ DESYA proposal to definitively determine the
contribution of multiple photon exchange in elastic lepton-nucleon scattering
Hampton University and Jefferson Lab Virginia, USA
Michael Kohl
JPOS09: Int. Workshop on Positrons at Jefferson Lab, March 25-27, 2009
![Page 2: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/2.jpg)
2
Overview
• Introduction• Motivation from previous data• Description of the proposed experiment• Summary
![Page 3: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/3.jpg)
3
Nucleon Elastic Form Factors … Fundamental quantities Defined in context of single-photon exchange
Describe internal structure of the nucleons Related to spatial distribution of charge and magnetism
Rigorous tests of nucleon models Determined by quark structure of the nucleon Ultimately calculable by Lattice-QCD Input to nuclear structure and
parity violation experiments
50 years of ever increasing activity
Tremendous progress in experiment and theory over last decade
New techniques / polarization experiments Unexpected results
![Page 4: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/4.jpg)
4
General definition of the nucleon form factor
Sachs Form Factors
In One-photon exchange approximation above form factors are observables of elastic electron-nucleon scattering
Nucleon Elastic Form Factors
![Page 5: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/5.jpg)
5
GM2
GE2
θ=180o θ=0o
Rosenbluth Separation
![Page 6: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/6.jpg)
6
GpE and Gp
M from Unpolarized Data
![Page 7: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/7.jpg)
7
GpE and Gp
M from Unpolarized Data
charge and magnetization density
Dipole form factor
within 5% for Q2 < 10 (GeV/c)2
![Page 8: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/8.jpg)
8
Double polarization in elastic/quasielastic ep or en scattering:Recoil polarization or (vector) polarized target
Polarized cross section
Double spin asymmetry = spin correlation
Asymmetry ratio (“Super ratio”)
independent of polarization or analyzing power
1,2H(e,e’p), 1,2H(e,e’p),
Nucleon Form Factors and Polarization
2H(e,e’n), 2H(e,e’n) , 3He(e,e’n),
![Page 9: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/9.jpg)
9
All Rosenbluth data from SLAC and Jlab in agreement
Dramatic discrepancy between Rosenbluth and recoil polarization technique
Multi-photon exchange considered best candidate
Jefferson Lab
Proton Form Factor Ratio
Dramatic discrepancy!
![Page 10: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/10.jpg)
10
Q2/(GeV/c)2
pG
p E/Gp M
0
0 2 4 6 8 10
1
Proton Form Factor RatioIachello 1973:
Drop of the ratio alreadysuggested by VMD
F. Iachello et al., PLB43 (1973) 191F. Iachello, nucl-th/0312074
A.V. Belitsky et al., PRL91 (2003) 092003G. Miller and M. Frank, PRC65 (2002) 065205S. Brodsky et al., PRD69 (2004) 076001Quark angular momentumHelicity non-conservation
![Page 11: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/11.jpg)
11
Two-Photon Exchange: A Lot of Theory
P.A.M. Guichon and M. Vanderhaeghen, PRL91 (2003) 142303: Formalism … TPE effect could be large
P.G. Blunden, W. Melnitchouk, and J.A. Tjon, PRC72 (2005) 034612, PRL91 (2003) 142304: Nucl. Theory … elastic ≈ half, Delta opposite
M.P. Rekalo and E. Tomasi-Gustafsson, EPJA22 (2004) 331: Importance of higher-order radiative effects
Y.C. Chen et al., PRL93 (2004) 122301: Partonic calculation, TPE large at high Q2
A.V. Afanasev and N.P. Merenkov, PRD70 (2004) 073002: Large logarithms in normal beam asymmetry
A.V. Afanasev, S.J. Brodsky, C.E. Carlson, Y.C. Chen, M. Vanderhaeghen, PRD72 (2005) 013008: high Q2, small effect on asym., larger on x-sec., TPE on R small
Y.C. Chen, C.W. Kao, S.N. Yang, PLB652 (2007) 269: Model-independent TPE large D. Borisyuk, A. Kobushkin, PRC74 (2006)065203; 78 (2008) 025208: TPE effect rather small! M. Kuhn, H. Weigel, EPJA38 (2008) 295: TPE in Skyrme Model D.Y. Chen et al., PRC78 (2008) 045208: TPE for timelike form factors M. Gorchtein, C.J. Horowitz, arXiv:0811.0614 [hep-ph]: gamma-Z box
Two-photon exchange theoretically suggestedInterference of one- and two-photon amplitudes
![Page 12: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/12.jpg)
12
TPE Predictions for e+/e- Ratio
Y.C. Chen, C.W. Kao, S.N. Yang PLB652 (2007) 269
Q2 = 1.75-5.0 (GeV/c)2
Q2 = 3.0 (GeV/c)2
D. Borisyuk, A. Kobushkin, PRC74 (2006)065203
P.G. Blunden, W. Melnitchouk, J.A. Tjon PRC72 (2005) 034612, PRL91 (2003) 142304
TPE effect large TPE effect small
TPE effect sizeable
TPE effect small
A.V. Afanasev, S.J. Brodsky,C.E. Carlson, Y.C. Chen, M. Vanderhaeghen, PRD72 (2005) 013008
![Page 13: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/13.jpg)
13
Precision comparison of positron-proton and electron-proton elastic scattering over a sizable ε range at Q2 ~ 2-3 (GeV/c)2
J. Arrington, PRC 69 (2004) 032201(R)
SLAC data
Θ=180o Θ=0o
At low ε : <Q2> ~ 0.01 to 0.8 (GeV/c)2
At high ε : <Q2> ~ 1-5 (GeV/c)2
Experiments to Verify 2 Exchange
![Page 14: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/14.jpg)
14
Two-photon exchange
Elastic electron-proton topositron-proton ratio (P. Blunden)
![Page 15: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/15.jpg)
15
Two-photon exchange
BLAST @ 2.0 GeVQ2 = 0.6–2.2 (GeV/c)2
Elastic electron-proton topositron-proton ratio (P. Blunden)
![Page 16: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/16.jpg)
16
Two-photon exchange
![Page 17: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/17.jpg)
17
OLYMPUS
pOsitron-proton and
eLectron-proton elastic scattering to test the
hYpothesis of
Multi-
Photon exchange
Using
DoriS
2008 – Full proposal2009/10 – Transfer of BLAST2011/12 – OLYMPUS Running
![Page 18: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/18.jpg)
18
Proposed Experiment
• Electrons/positrons (100mA) in multi-GeV storage ringDORIS at DESY, Hamburg, Germany
• Unpolarized internal hydrogen target (buffer system)3x1015 at/cm2 @ 100 mA → L = 2x1033 / (cm2s)
• Redundant monitoring of luminositypressure, temperature, flow, current measurementssmall-angle elastic scattering at high epsilon / low Q2
• Large acceptance detector for e-p in coincidenceBLAST detector from MIT-Bates available
• Measure ratio of positron-proton to electron-protonunpolarized elastic scattering to 1% stat.+sys.
![Page 19: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/19.jpg)
19
The BLAST Detector
Left-right symmetric
Large acceptance:0.1 < Q2/(GeV/c)2 < 0.820o < < 80o, -15o < < 15o
COILS Bmax = 3.8 kG
DRIFT CHAMBERSTracking, PID (charge)p/p=3%, = 0.5o
CERENKOV COUNTERSe/ separation
SCINTILLATORSTrigger, ToF, PID (/p)
NEUTRON COUNTERSNeutron tracking (ToF)
DRIFT CHAMBERS
CERENKOVCOUNTERS
SCINTILLATORS
NEUTRON COUNTERS
TARGETBEAM
BEAM
COILS
![Page 20: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/20.jpg)
20
The BLAST Detector
Bates
UNH
MIT
ASU
![Page 21: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/21.jpg)
21
Identification of Elastic Events
Charge +/-
Coplanarity
Kinematics
Timing
e’
p,d
BLAST1H(e,e’p)E=850 MeV
e- left, p+ right
e- right, p+ left
Advantages of magnetic field: suppression of background 2-3% momentum resolution
σθ = 0.5o and σφ = 0.5o
![Page 22: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/22.jpg)
22
Proton Form Factor Ratio pGpE/Gp
M*
*Ph.D. work of C. Crawford (MIT) and A. Sindile (UNH)
Impact of BLAST data combined with cross sections on separation of Gp
E and GpM
Errors factor ~2 smaller
Reduced correlation
Deviation from dipole at low Q2!
C.B. Crawford et al., PRL 98 (2007) 052301
![Page 23: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/23.jpg)
23
Neutron Electric Form Factor GnE
*Ph.D. work of V. Ziskin (MIT) and E. Geis (ASU)
*
E. Geis, M.K., V. Ziskin et al., PRL 101 (2008) 042501
![Page 24: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/24.jpg)
Proposed Experiment
• Electrons/positrons (100mA) in multi-GeV storage ringDORIS at DESY, Hamburg, Germany
• Unpolarized internal hydrogen target (buffer system)3x1015 at/cm2 @ 100 mA → L = 2x1033 / (cm2s)
• Large acceptance detector for e-p in coincidenceBLAST detector from MIT-Bates available
• Measure ratio of positron-proton to electron-protonunpolarized elastic scattering to 1% stat.+sys.
• Redundant monitoring of luminosity(pressure, temperature, flow, current measurements)small-angle elastic scattering at high epsilon / low Q2
![Page 25: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/25.jpg)
Luminosity Monitors: Telescopes
Forward telescopes
2 tGEM telescopes, 3 tracking planes 3.9 msr, 10o, R=160 cm, dR=10 cm
10o
![Page 26: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/26.jpg)
Forward Elastic Luminosity Monitor
• Forward angle electron/positron telescopes or trackers with good angular and vertex resolution
• Coincidence with proton in BLAST
• High rate capability
GEM technology
MIT protoype:
Telescope of 3 Triple GEM prototypes (10 x 10 cm2) using TechEtch foils
F. Simon et al., Nucl. Instr. and Meth. A 598 (2009) 432
![Page 27: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/27.jpg)
Control of Systematics
i = e+ or e-j= pos/neg polarity
Geometric proton efficiency:
Ratio in singlepolarity j
Geometric lepton efficiency:
![Page 28: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/28.jpg)
Control of Systematics
• Change between electrons and positrons every other day• Change BLAST polarity every other day• Left-right symmetry
Super ratio:
Cycle of four states ijRepeat cycle many times
![Page 29: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/29.jpg)
1000 hours eachfor e+ and e-
Lumi=2x1033 cm-2s-1
Projected Results for OLYMPUS
500 hours eachfor e+ and e-
Lumi=2x1033 cm-2s-1
![Page 30: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/30.jpg)
30
Experiments to Verify 2 Exchange
Experiment proposals to verify hypothesis:
e+/e- ratio: CLAS/PR04-116 secondary e+/e- beam Novosibirsk/VEPP-3 storage ring / internal target BLAST@DORIS/DESY storage ring / internal target
SSA: PR05-15 (Hall A)-dependence: PR04-119 (polarized), PR05-017 (unpolarized)
VEPP3 CLAS
![Page 31: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/31.jpg)
31
Summary
• Significant effect theoretically predicted, size uncertain• Convinced from feasibility of proposed experiment (2006)• Contacted DESY, idea presented to PRC in May 2007• Submitted letter of intent in June 2007• Presented to DOE at MIT review in July 2007• Intern. collaboration (~50 scientists, 11 inst.), April 2008• Submitted full proposal on invitation by DESY (Sep 2008)Next steps:
Fund raising in the US and in Europe (2009)Transfer of BLAST detector (2009-2010)Construction of new components (2009-2011)Running in 2011 and 2012, before DORIS to shut down
![Page 32: Hampton University and Jefferson Lab Virginia, USA](https://reader036.vdocuments.site/reader036/viewer/2022062301/56815da4550346895dcbd1c4/html5/thumbnails/32.jpg)
32
Nucleon Elastic Form Factors …
“All that we know and most of what we believe [in nuclear physics][…] is based on electron scattering and one-photon exchange” (W. Turchinetz)
“The electromagnetic probe is well understood, hence …”(a common phrase in many articles)
The elastic form factors characterize the simplest processin nuclear physics, namely elastic scattering (straightforward, one should think)
If we don’t understand the form factors, we will not have understood anything (my take on the importance of OLYMPUS)
Science = Belief replaced by knowledge