Halo SmartLaboratory Air Filtration System
User manualSaferSimpler
Halo Smart
2
Contents
General ....................................................................................................................................3
Safety notices .................................................................................................................3
Product registration ...................................................................................................3
Description of the unit ...........................................................................................4
Installation ............................................................................................................................6
Connectivity principle ..............................................................................................8
Sensors sensitivity settings .............................................................................19
Replacing the filters and the Pre-filter...............................................20
Recommendations for storing
and using the filters ..................................................................................................21
User Manual
3
General DescriptionHalo safely captures chemicals of the ambient air before recirculating clean air back into the laboratory.Easily mounted into the ceiling, HALO is totally independent of the building ventilation system.Utilizing the power of Erlab’s advanced carbon filtration technology, Halo retains a broad range of noxious chemical vapors while simultaneously improving the air quality of the lab.The exclusive sensor technology continuously evaluates the laboratory air quality and can be set according to the laboratory pollution (please check Halo’s operating mode on page 17 and sensor settings on page 19 to determine the best use for your laboratory). When Halo senses contaminants, the soft LED lights will pulse to let you know that the air is being cleaned. The usage and the management of each unit is possible via an embedded webportal from a smartphone, tablet or computer.
Safety noticesThe effectiveness of this device is directly dependent upon correct use and monitoring. The equipment provided is not intended to be used in an explosive atmosphere.
Keep away from any risk of liquid splashes. Do not installed outside of the laboratory.
Sensor replacement: VOCs sensor: every 5 years (semiconductor sensor)Acids (A) and Formadehyde (F) sensors: every 2 years (electrochemical sensors)After the usage time, Erlab cannot guarantee its stability and performance.
Product registration Take full advantage of the device’s connectivity to enhance your safety
Get up to 10 years warranty on your connected Erlab unit
Register your product online: the registration of the product will automatically give you one extra year of warranty (in addition to the warranty mentioned in the Erlab’ general terms and conditions of sale).
Connect your unit: Once the device is connected to the Internet and configured to exchange usage data, the warranty is extended for up to 10 years. Warranty will be successively renewed at each filters replacement and/or or at the end of filter usage time.
In order to benefit from Erlab extension of warranty offer, the following conditions shall be respected:
Warranty applicability is subject to the respect of the Erlab’ general terms and conditions of sale and following requirements:
• The registration and/or the connection of the product shall be performed within the twelve months from the purchase date;• Filters replacement must be performed following recommendations or at the end of filter usage time ; The filter’s serial number, used as an identification key, validates this condition, regardless of your device’s supplier (and/or the replacement filter’s supplier for the following years);• The device’s replacement filters must be manufactured by Erlab, as must all other spare parts.
Consumables such as filters and saturation sensors are not covered under warranty.
Halo Smart
4
Description of the unit
892 mm35’’ 1/8
592 mm 23’’5/16
Network and power ports
4 Attachment points
Side view
260 mm10’’1/4
205 mm8’’1/16 108 mm
4’’1/4
98 mm 3’’15/16
Above view Below view
User Manual
5
Specifications
Processed air flow 220 m3/h
Operating modes 24/7, Night/Day, Alert
Fan monitoring Halo unit monitors the air flow and informs the user through light pulsation communication
Pre filtration Particulate prefilter
Sensors
VOC Chemplus Acids Formaldehyde
Semiconductor for VOCs Semiconductor of a wide array of pollutants
Electro-chemical sensor for acids
Electro-chemical sensor for Formaldehyde
Smart-light Simple communication by LED pulsation system
e-Guard Communication Remote control and monitoring App
Ethernet Port 1 x RJ45 (included)
Installation Hung via 4 eye bolts (included)
Weight 31 kg (including filter)
Voltage / frequency 80-240V 50/60hz
Amperage 0.5 A (220 V) - 1 A (110 V)
Energy consumption 50 W
Halo Smart
6
InstallationMinimum protective equipment
• One-piece overall + overshoes + bouffant cap• Gloves• Protective glasses
According to the local regulations
1Fix the unit into the hard or drop ceiling trought its 4 attachment points.
2
Ceiling
Air outlets must be outside the hard or drop ceiling
User Manual
7
3 4
5Connect the power supply and the RJ45 socket to your network
1 2
4
It is recommended to install a switch between the electrical cable and the electrical outlet
3
Halo Smart
8
Connectivity principleEcosystem designed for simpler use and safer protection
Embeddedservice
Embeddedservice
Embeddedservice
Embeddedservice
Fume hood
Internet network and/or local areanetwork (LAN - for eGuard PC only)
Database
Monitoringthe product
Monitoring &controllingthe product
eGuard app
Mobile
PC
Ethernet-TCP-IP
Storage cabinet Air purifiers Air quality sensors
eGuard app - Options for connection
RJ45
Access WebServiceDefault IP address:
192.168.0.200If the network settingsare changed, copy thenew IP address here:
- Embedded service
Flash the QR code to access usage datas of
the device.
RJ45
RJ45RJ45 Ethernet
Routeur
or/and
QRcode
RJ45 (Data)
USB(Power 5V)
- Mobile or computer app
User Manual
9
3 OptionsEmbedded
serviceMobileApp
PCApp
Conditionsof use
Direct connection on PC with data cable (RJ45)
Web connection(via 3G/4G)
Web and/or local connection
Hardware requirements 1 PC + 1 cable 1 Apple or Android Smartphone
1 PC connected to Internet or local network
Parameters Monitoring + Controlling Monitoring Monitoring + Controlling
Data access One unit Multiple units Multiple units
Historical data access
Historical data download
Alerts, Notifications
Multiple units monitoring
Multiple user accounts
Automatized status report (except if local connection)
Download
available on www.erlab.com
Halo Smart
10
eGuard App – Embedded software
To monitor the parameters and modify the settings of the unit
In order to connect:
• Use a computer equipped with a Ethernet port (to plug the RJ45 cable)• WIFI of the computer must be switched off• Web browser (Internet Explorer, Edge, Chrome, Mozilla Firefox, Safari, …) must be installed on the computer
Note : RJ45 cable used to plug the unit to the computer is provided.
1 Direct connection on computer
If the network settings arechanged, copy the new IP address here:
_____________________
IP : 192.168.0.200Default IP address
RJ45
2 Open your web browser, type the following IP address 192.168.0.200 into the address bar and validate
OK
You are connected to the embedded softwareYou enter the « Status » page and you can have access to the « Settings » using the following credentials:Login : erlab / Password : smart
Please go to page 15
Page is not accessible
Computer network parameters are not allowing the access to the embedded software
Apply the following procedure
• Take RJ45 cable (black) already connected on the unit and rolled at the back of the control panel.
User Manual
11
Page is not accessible
1 Modify computer network parameters
Right click
Left click
Network parameters
Halo Smart
12
2 Access to the Network and sharing center
Left click
3 Access to the network connection
Right click
Left click to access properties
N.B : This confirms your WIFI is disconnected!
User Manual
13
4 Enter compatible network parameters as indicated below
Left click
Left click
Halo Smart
14
Write down your existing parameters before changing them in order to be able to set your initial parameters after the operation!
Enter the following parameters:
Validate
5 Open your web browser again, type again the following IP address 192.168.0.200 and validate
• OK : You are connected to the embedded software You enter the « Status » page and you can have access to the « Settings » using the following credentials: Login: erlab / Password : smart
User Manual
15
Administrator interface
Status page details
1 Choose active interface page
2 Device ID: Model
3 Device ID: serial number, MAC address, device status
4 Activates smart light to identify the unit location
5 Air quality gauge: indicates the air quality level (green: good air quality/Red: polluted air)
6 Indicates fan status
7 ON/OFF: Turn ON/OFF fan
8 Unit usage time since since its first usage
9 Air quality and sensor lifetime alarms
10 Volume setting
11 Embedded service version
12 Choose language
1
2
3 4
5
8
6
9 10
11 12
7
Halo Smart
16
Access to the settings with the following login credentials:
User name: erlab Password: smart
1
2
3
4
7
5
6
User Manual
17
Settings details
1 Device time and date settings
2
Device network settingsMode: Selected IP protocolHostname: Device name on networkIP: IP address of the deviceMASK: network maskGW: Network gateway
3
Activate/Deactivate the exchange of informationThis allows the transmission of information from the device to the eGuard server for:- remote monitoring via eGuard App (mobile &PC)- receiving usage reports
4
Halo operation modes
Mode : 24/7Halo is running 24/7
Mode : Min Max detection This mode defines a min. and max. fan powerDuring normal operation, the fan speed is defined by the value entered into the Min. setting. The Halo reaches its maximum fan speed if the sensor detects a pollution in the ambient air (the treshold value of the sensor has been reached).
Mode : Detection value only The ventilation is unactive.The fan automatically turns on its maximum if the sensor reaches its treshold value defined in the settings
Mode : Day / NightThis operating mode sets the fan to run during: Day (8am - 8pm) or night (8pm - 8am)
Minimum Setpoint: Min. fan speed of the Min Max Detection operating modeMaximum Setpoint: Max. fan speed for the Min. Max Detection and the Unique Detection operating modes Unique Setpoint: fan speedt of the 24/7 operating modeDay Setpoint: fan speed of the Day for the Day/Night operating modeNight Setpoint: fan speed of the Night for the Day/Night operating mode
5
Air Quality Sensor
Sensor type indication (VOCs: volatile organic compounds/ A: Acids / F: Formaldehyde)
Sensor sensitivity settings:VOCs sensor (5 settings): High sensitivity, Medium/High Sensitivity, Medium Sensitivity, Medium/Low Sensitivity,Low SensitivityA and F sensors (3 settings): High sensitivity, Medium Sensitivity, Low Sensitivity
Sensor replacementEnter replacement sensor date, display the next sensor replacement date
6 Current replacement date: last filter replacement dateNext replacement date: indicates the nest replacement date
7 Confirm settings key (please validate each setting)
Halo Smart
18
1
2
Log page details
1 Displays the device’s event log2 Used for downloading the log in .csv format
User Manual
19
Sensors sensitivity settings Settings recommended by Erlab
Halo Smart – VOC version
Chemical products PEL/TWA 8H (ppm)
PEL/STEL (ppm)
High sensitivity
(ppm)
Medium high sensitivity
(ppm)
Medium sensitivity
(ppm)
Low Medium sensitivity
(ppm)
Low sensitivity
(ppm)
Ammonia 10 20 10 15 25
Hexane 20 1 2 5 15 20
Xylene 50 100 0 0.3 0.5 1.5 2
Acetonitrile 40 30 40
Toluene 20 100 0 0.5 0.7 2 3
Isopropanol 400 1 1.5 2 3 5
Acetone 500 1000 1 3 5 6.5 8
Methanol 200 1000 1 2 5 10 15
Ethanol 1000 5000 1 2 5 10 15
Diethyl ether 100 200 1 2 5 8 10
Halo Smart – Acids version
Chemical products PEL/TWA 8H (ppm)
PEL/STEL (ppm)
High sensitivity (ppm)
Mediumsensitivity
(ppm)
Low sensitivity(ppm)
Hydrochloric acid 5 ppm 0.5 ppm 1 ppm 2 ppm
Nitric acid 1 ppm 1 ppm
Hydrobromic acid 2 ppm 0.5 ppm 1 ppm
N.B: Halo Smart is not adapted to sense hydrofluoric acid
Halo Smart – Formaldehyde version
Chemical products PEL/TWA 8H (ppm)
PEL/STEL (ppm)
High sensitivity (ppm)
Mediumsensitivity
(ppm)
Low sensitivity(ppm)
Formaldehyde 0.5 ppm 1 ppm 0.1 ppm 0.5 ppm 1 ppm
Halo Smart
20
Replacing the filters and the Pre-filter
Pre-filter replacement
1 2
3 4
5 6
1 2
* US model does not have thumb screws
26.5 lbs
* US model does not have thumb screws
New filter
New pre-filter
!Filter12 Kg
Replacing the carbon filter
User Manual
21
Recommendations for storing and using the filtersNew filter shelf life and storage conditions:New activated carbon molecular filters must be stored flat in their original packaging at a temperature of between +10°C / 50°F and +50°C / 120° F and a humidity level < 85% RH.
If these conditions are adhered to, the maximum time a filter can be stored before use depends on the type of carbon used:
- AS type carbon molecular filter 2 years from the date of delivery- BE+ type carbon molecular filter 2 years from the date of delivery- BE type carbon molecular filter 1 year from the date of delivery- F type carbon molecular filter 1 year from the date of delivery- K type carbon molecular filter 1 year from the date of delivery
If the maximum shelf life is reached, we recommend to not install filters.
Predicted service life of a filter once put into use:The service life of a molecular filter depends on lab air quality as well as the conditions of the environment in which it is used. We recommend replacing the filter annually (if used 24/7).
Failing that and/or in the absence of information regarding device usage: ERLAB is unable to provide any guidance as to the predicted service life of the filter(s). In such cases, we strongly recommend:• That the molecular filters are replaced at least every 12 months and that a regular filter saturation checking protocol is put in place (please contact us for individual advice on this subject)
1 Erlab R&D Laboratory The engineers and chemists in our state-of-the-art R&D laboratory understand molecular filtration. We are committed to
designing products that are safe and of the highest quality, strive to improve our products, and continuously develop new products that provide greater protection in the laboratory.
2 Strict Safety Standards We hold ourselves to the highest standard and adhere to the strict AFNOR NF X 15-211: 2009 filtration safety standard
as endorsed by ANSI Z9.5-2012.
3 A Published Chemical Listing It all begins here. Without this listing, we are not compliant with AFNOR NFX 15-211. Our in-house laboratory tests, as well
as independent testing to verify the retention capacity of over 700 chemicals for our filters.
4 Independent Testing Erlab filters have been independently tested multiple times at various concentrations guaranteeing that our safety
solutions all adhere to the strict performance criteria of the AFNOR NF X 15-211:2009 standard assuring that the emission concentration at the filter exhaust will always be lower than 1% of the TLV.
5 Application Questionnaire (Valiquest) Our laboratory specialists will recommend the appropriate filtration fume hood, type of filter, and personalized advice.
6 Certificate of Validation for the chemicals used in the hood A certified PhD chemist issues a Certificate of Validation with a list of the chemicals approved for use in the hood.
7 Our Safety Program We back up our products 100%. This program includes your specialized chemical evaluation, validation of your hood
upon installation, and a filtration safety specialist at your service to ensure that your hood is operating to its full potential.
We provide safety, we protect your healthErlab invented the ductless fume hood in 1968. With more than 45 years of experience in the field of chemical filtration and protection of laboratory personnel; we know the formula for safety. With Erlab, you will never have to wonder or worry if our products are safe. We build each one of the following 7 ingredients into our products, and without all of them, your health and safety will be compromised.
France +33 (0) 2 32 09 55 80 │ [email protected]
Germany 0800 330 47 31│ [email protected]
China +86 (0) 512 5781 4085 │ [email protected]
Italy +39 (0) 2 89 00 771 │ [email protected]
Malaysia +60 (0) 7 3 555 724 │ [email protected]
Spain +34 93 673 24 74 │ [email protected]
North America+1 800-964-4434 │ [email protected]
United Kingdom +44 (0) 1722 341 940 │[email protected]
www.erlab.com
About Erlab
Le laboratoire de Recherche et Développement Erlab
Hal
o_V
04_2
017_
10 -
Erl
ab F
ranc
e - T
echn
ical
dat
a ar
e no
t co
ntra
ctua
l. Er
lab®
DFS
SA
S re
serv
es t
he r
ight
to
mod
ify t
he p
rese
nt d
ocum
ent
with
out
prio
r no
tice.
Erlab’s state of the art Research & Development Laboratory relying exclusively on filtration