• Pit Depth:- For speeds up to 150 fpm is 4’-0”.- For speeds between 151 to 200 fpm is 5’-0”.Pit required clearances as required by ASME A17.1/CSA B44 Safety Code.
• Clear Overhead:(based on the standard 8’- 0” cab height):- For speeds up to 150 fpm – 12’-6” is required.- For speeds between 151-200 fpm – 13’-0” is required.Overhead required clearances as required by ASME A17.1/CSA B44 Safety Code.
• Car Size:- All elevators comply with NEII and ADA space requirements for Wheelchair access.- 2100 lbs elevators must have Single Slide Handed doors to comply with NEII and ADArequirements for Wheelchairs access.- 3000 lbs and 3500 lbs elevators shown here comply with NEII and ADA requirementsAmbulance Stretcher access, unless equipped with Center Parting doors.
Notes:1. Adequate supports for main rails, as well as jack units and support posts arerequired at vertical intervals in the elevator hoistway. Normal vertical spacing for thesesupports is approximately 9’- 0”. As such, supports at floor levels only may not beadequate. Support locations are to be masonry or steel construction. If a block (CMU)hoistway is provided the block must be filled with mortar around the wall insert toprovide a rigid structure.2. A pit ladder is to be provided and installed by others, which is required inaccordance with ASME A17.1/CSA B44 Safety Code.3. Top of hoistway must be vented, in accordance with ASME A17.1/CSA B44 SafetyCode and local building code(s).4. An 110V AC power GFI outlet is required in the pit.5. The hoist beam required for installation of elevator must be removed (by others) ifminimum cab clearance is not available under the beam.
Machine Room1. An area of 6’- 0” x 7’- 0” x 8”- 0” high is usually adequate for a single car installation,with a 3’-0” wide door opening for access.2. Recommended location is adjacent to the hoistway at the bottom landing served.MachineRoom can be remotely located at any landing or above the hoistway – please consultthe factory.3. Machine room temperature (between 650 and 950 Fahrenheit) and humidity needsto be maintained in accordance with ASME A17.1/CSA B44 Safety Code to allow proper operation of the equipment.4. Machine room to be adequate lighted with an 110V AC power GFI outlet.
Date ____________ Date Required ____________ Ship Date Required ____________
Email: [email protected] w Website: www.elevatorequipment.com w Telephone: (888) 577-3326 w Fax: (888) 577-3116
Company _____________________________________________
Address _____________________________________________
City _______________________ .St. _____ Zip ________
Project Name _______________________ .St. _____ Zip ________
Contact _______________________________________________
Phone _______________ Ext. ______ Fax ________________
Cell Phone _______________________________________________
Email _______________________________________________
Group One - Roped HydraulicQuotation Request / Order Form
# of Cars _____ Dual Jacks Cantilever
Plans / Specs Fax Verbal
Passenger Seismic - Zone ____ Freight
Load Class A B C1 C2 C3
Code Requirements ASME 17.1 - ________ Year Local Code ________
Buy American Requirement
Car Type
Isolated Platform Limit Switches Isolation Coupling __________ qty Shut Off Valve __________ qty
Include Motor Control with Enclosure Y-Delta ATL Solid State
Tank Mounted Wall Mounted
Valve Return Filter Adjustable Load Weighing Switch
Low Pressure Switch N.O. N.O./N.C.
Viscosity Switch Oil Heater Oil Cooler Air Water Power Unit Hand Pump Scavenger Pump
Single Piece Multi-Piece No. of Sections ______________ or Longest Section ______________
Cylinder Joint Type Threaded No Weld Threaded Slip Fit (Up to 16”) Butt Weld
Seamless Pipe Epoxy Paint __________ Coats
Use with Biodegradable Oil (Vegetable)
Submersible Belt Drive 80 Starts/Hr 120 Starts/Hr Custom (Specify) ______________________________________________________
Other OEM Control Valve ______________ Non-Constant Down Speed EECO Dampener Upgrade
Oil Line Size __________ in _ Grooved (Std) NPT Left Hand (Std) Right Hand Schedule 40 Schedule 80
Overhead _________ ft _________ inFloor Travel _________ ft _________ in
Pit Depth _________ ft _________ inCab Height _________ h
Number of Landings _________ qtyTotal Openings _________ qty
Front Openings _________ qty Left Center Right
Rear Openings _________ qty Left Center Right
Side Openings _________ qty Left Center Right
Hoistway Details
Jack Unit Options & AccessoriesPower Unit
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Special Requirements
Hoistway _________ w _________ hPlatform _________ w _________ d
Capacity __________ lbsCab Weight __________ lbs
Power Supply ____ V _____ Ph _____ HzCoil Voltage ____ V AC DC ___ Hz
Car Doors Speed Single Two Three
Entrance Size _______ w _______ h
Machine Room Adj. @ Lowest Level Machine Room Remote ______ ft Machine Room Location ______ Landing Shared Machine Room
as well as many other applications
Group one roped Hydraulic elevators
Date ____________ Date Required ____________ Ship Date Required ____________
Company _____________________________________________
Address _____________________________________________
City _______________________ .St. _____ Zip ________
Project Name _______________________ .St. _____ Zip ________
Contact _______________________________________________
Phone _______________ Ext. ______ Fax ________________
Cell Phone _______________________________________________
Email _______________________________________________
Group One - Roped HydraulicQuotation Request / Order Form
# of Cars _____ Dual Jacks CantileverCar Speed ______ fpm
Plans / Specs Fax Verbal
Passenger Seismic - Zone ____ Freight
Load Class A B C1 C2 C3
Code Requirements ASME 17.1 - ________ Year Local Code ________
Buy American RequirementCapacity __________ lbsCab Weight __________ lbs Cab Height _________ h
Car Type Isolated Platform Limit Switches __________ qty Ad. Isolation Coupling __________ qty Ad. Shut Off Valve __________ qty Prewired Junction Box Include Motor Control with Enclosure Y-Delta ATL Solid State
Tank Mounted Wall Mounted
Adjustable Load Weighing SwitchLow Pressure Switch
N.O. N.O./N.C.
Oil Cooler Air Water Scavenger Pump Use with Biodegradable Oil (Vegetable)
Single Piece Multi-Piece No. of Sections ______________ or Longest Section ______________
Cylinder Joint Type Threaded No Weld Threaded Slip Fit (Up to 16”) Butt Weld
Seamless Pipe Epoxy Paint __________ Coats
Overhead _________ ft _________ inFloor Travel _________ ft _________ in Pit Depth _________ ft _________ inNumber of Landings _________ qtyTotal Openings _________ qty
Car Doors Single Two Three
Entrance Size _______ w _______ h
Front Openings _________ qty Left Center Right
Rear Openings _________ qty Left Center Right
Side Openings _________ qty Left Center Right
Hoistway Details
Jack Unit Options & Accessories
Contact Sales forMore Information
Submersible Belt Drive 80 Starts/Hr 120 Starts/Hr Left Hand (Std) Right HandPower Supply ____ V _____ Ph _____ HzCoil Voltage ____ V AC DC ___ Hz Custom (Specify) _____________________________________________________
Other OEM Control Valve______________ Non-Constant Down Speed Valve Return Filter EECO Dampener Upgrade
Oil Line Size __________ in _ Grooved (Std) NPT Schedule 40 Schedule 80 Viscosity Switch Oil Heater Power Unit Hand Pump
Power Unit
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Special Requirements
Hoistway _________ w _________ hPlatform _________ w _________ d
Machine Room Adj. @ Lowest LevelMachine Room Remote ______ ftMachine Room Location ______ Landing Shared Machine Room (duplex)
Call: (888) 577-EECO (3326)Fax: (888) 577-3116
Email: [email protected]: www.elevatorequipment.com
• Roped Hydraulic ◦ Sheaves and Stabilizer ◦ Wire Rope and Shackles
Hydraulic JacksEECO manufactures jack units with precision equipment, skilled and experienced production personnel, and a knowledgeable engineering staff to comply with the exacting standards required to produce a quality product. Additional equipment included with jack units is described below per system type.
• Submersible or Belted (Horsepower Driven) ◦ Tank ◦ Pump ◦ Motor ◦ EECO UV-5ATC or UV-7BC Control Valve
▪ Low Pressure Switch (if required) ▪ 1/8” Pressure Gauge Fittings ▪ Down Speed Control
◦ Grooved Outlet (Threaded when required) ◦ Dampener or Muffler ◦ Thermal Switch ◦ Low Oil Switch ◦ Oil Level Liquid Gauge ◦ Magnet ◦ Optional Pre-wired Junction Box ◦ Optional Motor Control
Power Units EECO has manufactured hydraulic elevator equipment since 1946, and is one of the leading suppliers in the industry fVor hydraulic elevator power units. We can provide power units for any application, from small capacity residential to the largest freight elevators.
• Rail Guides◦ Speed Up To 149 fpm Slide Guides◦ Speed 150 – 200 fpm Roller Guides with
Polyurethane Wheels• Platform has two layers of (2) 1/2” plywood
subflooring with an undercoating of Fire Retardant Paint or sheet metal if required.
• Tie Rods• Car Cam• Toe Guard• Strike Plate• Optional Limit Switches• Isolated Platen Connection Plate• Safeties and Slack Rope Switch• Governor
◦ Tension weight◦ Wire Rope◦ Mounting Bracket
Sling and Platform In addition to the Group One package, EECO can design and manufacture a car sling or platform to any size for any requirement that you may have. From home elevators to commercial passenger elevators, up to the biggest freight elevators, EECO can handle the job.
• 15 lb/ft Guide Rails• Fishplate and Hardware (Seismic when required)• 12” wide Rail Brackets (9” wide for Telescopic
when Piston Followers are required)
Rail and Rail Brackets EECO provides the highest quality rail equipment, including seismic components when required.
• Black Pipe• Grooved Fittings (Threaded when required)• Pipe Stands• Shut Off Valve• Isolation Coupling• Pipe Rupture Valve (when required)
Oil Line Components EECO’s Group One system provides the basic components you need for your elevator installation.
EECO GrOup OnE COmpOnEntsEECO rOpEd CantilEvEr HOlElEssEECO rOpEd dual HOlElEss
• Roped Hydraulic ◦ Sheaves and Stabilizer ◦ Wire Rope and Shackles
Hydraulic JacksEECO manufactures jack units with precision equipment, skilled and experienced production personnel, and a knowledgeable engineering staff to comply with the exacting standards required to produce a quality product. Additional equipment included with jack units is described below per system type.
• Submersible or Belted (Horsepower Driven) ◦ Tank ◦ Pump ◦ Motor ◦ EECO UV-5ATC or UV-7BC Control Valve
▪ Low Pressure Switch (if required) ▪ 1/8” Pressure Gauge Fittings ▪ Down Speed Control
◦ Grooved Outlet (Threaded when required) ◦ Dampener or Muffler ◦ Thermal Switch ◦ Low Oil Switch ◦ Oil Level Liquid Gauge ◦ Magnet ◦ Optional Pre-wired Junction Box ◦ Optional Motor Control
Power Units EECO has manufactured hydraulic elevator equipment since 1946, and is one of the leading suppliers in the industry fVor hydraulic elevator power units. We can provide power units for any application, from small capacity residential to the largest freight elevators.
• Rail Guides◦ Speed Up To 149 fpm Slide Guides◦ Speed 150 – 200 fpm Roller Guides with
Polyurethane Wheels• Platform has two layers of (2) 1/2” plywood
subflooring with an undercoating of Fire Retardant Paint or sheet metal if required.
• Tie Rods• Car Cam• Toe Guard• Strike Plate• Optional Limit Switches• Isolated Platen Connection Plate• Safeties and Slack Rope Switch• Governor
◦ Tension weight◦ Wire Rope◦ Mounting Bracket
Sling and Platform In addition to the Group One package, EECO can design and manufacture a car sling or platform to any size for any requirement that you may have. From home elevators to commercial passenger elevators, up to the biggest freight elevators, EECO can handle the job.
• 15 lb/ft Guide Rails• Fishplate and Hardware (Seismic when required)• 12” wide Rail Brackets (9” wide for Telescopic
when Piston Followers are required)
Rail and Rail Brackets EECO provides the highest quality rail equipment, including seismic components when required.
• Black Pipe• Grooved Fittings (Threaded when required)• Pipe Stands• Shut Off Valve• Isolation Coupling• Pipe Rupture Valve (when required)
Oil Line Components EECO’s Group One system provides the basic components you need for your elevator installation.
EECO GrOup OnE COmpOnEntsEECO rOpEd CantilEvEr HOlElEssEECO rOpEd dual HOlElEss
• Roped Hydraulic ◦ Sheaves and Stabilizer ◦ Wire Rope and Shackles
Hydraulic JacksEECO manufactures jack units with precision equipment, skilled and experienced production personnel, and a knowledgeable engineering staff to comply with the exacting standards required to produce a quality product. Additional equipment included with jack units is described below per system type.
• Submersible or Belted (Horsepower Driven) ◦ Tank ◦ Pump ◦ Motor ◦ EECO UV-5ATC or UV-7BC Control Valve
▪ Low Pressure Switch (if required) ▪ 1/8” Pressure Gauge Fittings ▪ Down Speed Control
◦ Grooved Outlet (Threaded when required) ◦ Dampener or Muffler ◦ Thermal Switch ◦ Low Oil Switch ◦ Oil Level Liquid Gauge ◦ Magnet ◦ Optional Pre-wired Junction Box ◦ Optional Motor Control
Power Units EECO has manufactured hydraulic elevator equipment since 1946, and is one of the leading suppliers in the industry fVor hydraulic elevator power units. We can provide power units for any application, from small capacity residential to the largest freight elevators.
• Rail Guides◦ Speed Up To 149 fpm Slide Guides◦ Speed 150 – 200 fpm Roller Guides with
Polyurethane Wheels• Platform has two layers of (2) 1/2” plywood
subflooring with an undercoating of Fire Retardant Paint or sheet metal if required.
• Tie Rods• Car Cam• Toe Guard• Strike Plate• Optional Limit Switches• Isolated Platen Connection Plate• Safeties and Slack Rope Switch• Governor
◦ Tension weight◦ Wire Rope◦ Mounting Bracket
Sling and Platform In addition to the Group One package, EECO can design and manufacture a car sling or platform to any size for any requirement that you may have. From home elevators to commercial passenger elevators, up to the biggest freight elevators, EECO can handle the job.
• 15 lb/ft Guide Rails• Fishplate and Hardware (Seismic when required)• 12” wide Rail Brackets (9” wide for Telescopic
when Piston Followers are required)
Rail and Rail Brackets EECO provides the highest quality rail equipment, including seismic components when required.
• Black Pipe• Grooved Fittings (Threaded when required)• Pipe Stands• Shut Off Valve• Isolation Coupling• Pipe Rupture Valve (when required)
Oil Line Components EECO’s Group One system provides the basic components you need for your elevator installation.
EECO GrOup OnE COmpOnEntsEECO rOpEd CantilEvEr HOlElEssEECO rOpEd dual HOlElEss
• Pit Depth:- For speeds up to 150 fpm is 4’-0”.- For speeds between 151 to 200 fpm is 5’-0”.Pit required clearances as required by ASME A17.1/CSA B44 Safety Code.
• Clear Overhead:(based on the standard 8’- 0” cab height):- For speeds up to 150 fpm – 12’-6” is required.- For speeds between 151-200 fpm – 13’-0” is required.Overhead required clearances as required by ASME A17.1/CSA B44 Safety Code.
• Car Size:- All elevators comply with NEII and ADA space requirements for Wheelchair access.- 2100 lbs elevators must have Single Slide Handed doors to comply with NEII and ADArequirements for Wheelchairs access.- 3000 lbs and 3500 lbs elevators shown here comply with NEII and ADA requirementsAmbulance Stretcher access, unless equipped with Center Parting doors.
Notes:1. Adequate supports for main rails, as well as jack units and support posts arerequired at vertical intervals in the elevator hoistway. Normal vertical spacing for thesesupports is approximately 9’- 0”. As such, supports at floor levels only may not beadequate. Support locations are to be masonry or steel construction. If a block (CMU)hoistway is provided the block must be filled with mortar around the wall insert toprovide a rigid structure.2. A pit ladder is to be provided and installed by others, which is required inaccordance with ASME A17.1/CSA B44 Safety Code.3. Top of hoistway must be vented, in accordance with ASME A17.1/CSA B44 SafetyCode and local building code(s).4. An 110V AC power GFI outlet is required in the pit.5. The hoist beam required for installation of elevator must be removed (by others) ifminimum cab clearance is not available under the beam.
Machine Room1. An area of 6’- 0” x 7’- 0” x 8”- 0” high is usually adequate for a single car installation,with a 3’-0” wide door opening for access.2. Recommended location is adjacent to the hoistway at the bottom landing served.MachineRoom can be remotely located at any landing or above the hoistway – please consultthe factory.3. Machine room temperature (between 650 and 950 Fahrenheit) and humidity needsto be maintained in accordance with ASME A17.1/CSA B44 Safety Code to allow proper operation of the equipment.4. Machine room to be adequate lighted with an 110V AC power GFI outlet.
Date ____________ Date Required ____________ Ship Date Required ____________
Email: [email protected] w Website: www.elevatorequipment.com w Telephone: (888) 577-3326 w Fax: (888) 577-3116
Company _____________________________________________
Address _____________________________________________
City _______________________ .St. _____ Zip ________
Project Name _______________________ .St. _____ Zip ________
Contact _______________________________________________
Phone _______________ Ext. ______ Fax ________________
Cell Phone _______________________________________________
Email _______________________________________________
Group One - Roped HydraulicQuotation Request / Order Form
# of Cars _____ Dual Jacks Cantilever
Plans / Specs Fax Verbal
Passenger Seismic - Zone ____ Freight
Load Class A B C1 C2 C3
Code Requirements ASME 17.1 - ________ Year Local Code ________
Buy American Requirement
Car Type
Isolated Platform Limit Switches Isolation Coupling __________ qty Shut Off Valve __________ qty
Include Motor Control with Enclosure Y-Delta ATL Solid State
Tank Mounted Wall Mounted
Valve Return Filter Adjustable Load Weighing Switch
Low Pressure Switch N.O. N.O./N.C.
Viscosity Switch Oil Heater Oil Cooler Air Water Power Unit Hand Pump Scavenger Pump
Single Piece Multi-Piece No. of Sections ______________ or Longest Section ______________
Cylinder Joint Type Threaded No Weld Threaded Slip Fit (Up to 16”) Butt Weld
Seamless Pipe Epoxy Paint __________ Coats
Use with Biodegradable Oil (Vegetable)
Submersible Belt Drive 80 Starts/Hr 120 Starts/Hr Custom (Specify) ______________________________________________________
Other OEM Control Valve ______________ Non-Constant Down Speed EECO Dampener Upgrade
Oil Line Size __________ in _ Grooved (Std) NPT Left Hand (Std) Right Hand Schedule 40 Schedule 80
Overhead _________ ft _________ inFloor Travel _________ ft _________ in
Pit Depth _________ ft _________ inCab Height _________ h
Number of Landings _________ qtyTotal Openings _________ qty
Front Openings _________ qty Left Center Right
Rear Openings _________ qty Left Center Right
Side Openings _________ qty Left Center Right
Hoistway Details
Jack Unit Options & AccessoriesPower Unit
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Special Requirements
Hoistway _________ w _________ hPlatform _________ w _________ d
Capacity __________ lbsCab Weight __________ lbs
Power Supply ____ V _____ Ph _____ HzCoil Voltage ____ V AC DC ___ Hz
Car Doors Speed Single Two Three
Entrance Size _______ w _______ h
Machine Room Adj. @ Lowest Level Machine Room Remote ______ ft Machine Room Location ______ Landing Shared Machine Room
as well as many other applications
Group one roped Hydraulic elevators
Date ____________ Date Required ____________ Ship Date Required ____________
Company _____________________________________________
Address _____________________________________________
City _______________________ .St. _____ Zip ________
Project Name _______________________ .St. _____ Zip ________
Contact _______________________________________________
Phone _______________ Ext. ______ Fax ________________
Cell Phone _______________________________________________
Email _______________________________________________
Group One - Roped HydraulicQuotation Request / Order Form
# of Cars _____ Dual Jacks CantileverCar Speed ______ fpm
Plans / Specs Fax Verbal
Passenger Seismic - Zone ____ Freight
Load Class A B C1 C2 C3
Code Requirements ASME 17.1 - ________ Year Local Code ________
Buy American RequirementCapacity __________ lbsCab Weight __________ lbs Cab Height _________ h
Car Type Isolated Platform Limit Switches __________ qty Ad. Isolation Coupling __________ qty Ad. Shut Off Valve __________ qty Prewired Junction Box
Include Motor Control with Enclosure Y-Delta ATL Solid State
Tank Mounted Wall Mounted
Adjustable Load Weighing SwitchLow Pressure Switch
N.O. N.O./N.C.
Oil Cooler Air Water Scavenger Pump Use with Biodegradable Oil (Vegetable)
Single Piece Multi-Piece No. of Sections ______________ or Longest Section ______________
Cylinder Joint Type Threaded No Weld Threaded Slip Fit (Up to 16”) Butt Weld
Seamless Pipe Epoxy Paint __________ Coats
Overhead _________ ft _________ inFloor Travel _________ ft _________ in Pit Depth _________ ft _________ inNumber of Landings _________ qtyTotal Openings _________ qty
Car Doors Single Two Three
Entrance Size _______ w _______ h
Front Openings _________ qty Left Center Right
Rear Openings _________ qty Left Center Right
Side Openings _________ qty Left Center Right
Hoistway Details
Jack Unit Options & Accessories
Contact Sales forMore Information
Submersible Belt Drive 80 Starts/Hr 120 Starts/Hr Left Hand (Std) Right HandPower Supply ____ V _____ Ph _____ HzCoil Voltage ____ V AC DC ___ Hz Custom (Specify) _____________________________________________________
Other OEM Control Valve______________ Non-Constant Down Speed Valve Return Filter EECO Dampener Upgrade
Oil Line Size __________ in _ Grooved (Std) NPT Schedule 40 Schedule 80 Viscosity Switch Oil Heater Power Unit Hand Pump
Power Unit
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Special Requirements
Hoistway _________ w _________ hPlatform _________ w _________ d
Machine Room Adj. @ Lowest LevelMachine Room Remote ______ ftMachine Room Location ______ Landing Shared Machine Room (duplex)
Call: (888) 577-EECO (3326)Fax: (888) 577-3116
Email: [email protected]: www.elevatorequipment.com
Date ____________ Date Required ____________ Ship Date Required ____________
Company _____________________________________________
Address _____________________________________________
City _______________________ .St. _____ Zip ________
Project Name _______________________ .St. _____ Zip ________
Contact _______________________________________________
Phone _______________ Ext. ______ Fax ________________
Cell Phone _______________________________________________
Email _______________________________________________
Group One - Roped HydraulicQuotation Request / Order Form
# of Cars _____ Dual Jacks CantileverCar Speed ______ fpm
Plans / Specs Fax Verbal
Passenger Seismic - Zone ____ Freight
Load Class A B C1 C2 C3
Code Requirements ASME 17.1 - ________ Year Local Code ________
Buy American RequirementCapacity __________ lbsCab Weight __________ lbs Cab Height _________ h
Car Type Isolated Platform Limit Switches __________ qty Ad. Isolation Coupling __________ qty Ad. Shut Off Valve __________ qty Prewired Junction Box
Include Motor Control with Enclosure Y-Delta ATL Solid State
Tank Mounted Wall Mounted
Adjustable Load Weighing SwitchLow Pressure Switch
N.O. N.O./N.C.
Oil Cooler Air Water Scavenger Pump Use with Biodegradable Oil (Vegetable)
Single Piece Multi-Piece No. of Sections ______________ or Longest Section ______________
Cylinder Joint Type Threaded No Weld Threaded Slip Fit (Up to 16”) Butt Weld
Seamless Pipe Epoxy Paint __________ Coats
Overhead _________ ft _________ inFloor Travel _________ ft _________ in
Pit Depth _________ ft _________ inNumber of Landings _________ qty
Total Openings _________ qty
Car Doors Single Two Three
Entrance Size _______ w _______ h
Front Openings _________ qty Left Center Right
Rear Openings _________ qty Left Center Right
Side Openings _________ qty Left Center Right
Hoistway Details
Jack Unit Options & Accessories
Contact Sales forMore Information
Submersible Belt Drive 80 Starts/Hr 120 Starts/Hr Left Hand (Std) Right HandPower Supply ____ V _____ Ph _____ HzCoil Voltage ____ V AC DC ___ Hz Custom (Specify) _____________________________________________________
Other OEM Control Valve ______________ Non-Constant Down Speed Valve Return Filter EECO Dampener Upgrade
Oil Line Size __________ in _ Grooved (Std) NPT Schedule 40 Schedule 80 Viscosity Switch Oil Heater Power Unit Hand Pump
Power Unit
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Special Requirements
Hoistway _________ w _________ dPlatform _________ w _________ d
Machine Room Adj. @ Lowest Level Machine Room Remote ______ ft Machine Room Location ______ Landing Shared Machine Room (duplex)
Call: (888) 577-EECO (3326)Fax: (888) 577-3116
Email: [email protected]: www.elevatorequipment.com
1/5/16FS-019