ground floor tgds
TRANSCRIPT
BookableRoom 23
m²
BookableRoom 28
m²
Circulation30 m²
SpeechTherapy17 m²
ChildHealth 18
m²
BookableRoom 18
m²
BookableRoom 15
m²
CleanersStorage10 m²
Circulation44 m²
Stairs 16m²
SoundProof
Room 16m²
ChildHealth 22
m²
SpeechTherapy13 m²
WoundClinic 28
m²
Circulation27 m²
ExaminationRoom 13
m²
WoundClinic 18
m²
MedicalStore 10
m²
BookableRoom 19
m²
BookableRoom 17
m²
CommunityWelfare30 m²
Store 6m²
FamilyRoom 30
m²Reception& WaitingArea 78
m²
Restaurant89 m²
OTGARoom 51
m²
Care DocSuite 55
m² PhysioTreatment
93 m²
HSETreatmentRoom 55
m²
HSEOffice 14
m²Reception5 m²
Hall 12m²
HSEStore 11
m²
HSE DrRoom 28
m²
PrivateMedical
Suite 114m²
PrivateMedical
Suite 131m²
60 FD
30 FD
60 FD
60 FD
60 FD
60 FD
60 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD 30 FD
30 FD30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
30 FD
60 FD
MAIN ENTRANCE
FIRE EXIT
FIRE EXIT
FIRE EXIT
60 FD60 FD
The north staircase is accessible to all floors therefore thebasement area must be separated from the other floors in caseof fire, not to release smoke to other areasAmbulant disabled stairs have a riser of 175mm and a going of300mm, the width of the stairs is 1500mm, the headroom mustbe a minimum of 2400mm, handrails are present on each sideof the stairs at a height of 1000mmThere is a Refuge Space on the right side of the exitDoors to the exit are 60 Minute fire rated doors
Refuge spaceThere is a Bed Lift and aNominal Lift present at basementlevel, both of which should not beused in case of fire.
An additional lobby must beprovided in order to not let anysmoke to other floor levels incase of fire
Refuge Space
60 FD 60 Minute Fire Rated Doors
Refuge Space
Fire Rated Wall Construction
30 FD
30 FD
Hall 20m²
30 FD
Hall 17m²
Technical Guidance Document: Part B
According to TGD B Appendix A, Table A1; Structural frames,columns, beams, load bearing walls and floor structures shouldbe enclosed by 60 minute fire resistant plasterboard casing.
Means of escape in case of fireEscape RoutesEscape routes should be independent or otherwise comply withthe following:a) In directions of 45° and a minimum of 1000mm wide.b) Must be separated by fire resisting construction if less than45° apart.
Final ExitsAll exits are the same width or wider than the escape routesand give direct access to the open passage. The widths of finalexits should be adequate enough to support the expectedamount of users during a case of fire.Basement staircase should be separated from the rest of thebuilding encase of fire and smoke entering the rest of thebuilding up to second floor level.
Openings in Cavity BarriersDoors which have at least 15 minutes fire resistance refer toTGD B Appendix B, Table B1, item 8(a), the doors are fitted inaccordance with the provisions of TGD B Appendix BThe passage of pipes should meet the provisions with TGDsub-section 3.4Ducts which unless they are fire resisting are fitted withsuitably mounted automatic fire shutter where they passthrough the cavity barrier.
Fire Escape Travel DistancesLongest travel distance in more than one direction should be 45meters and in one direction 18metres.
Special precaution should be made for wallsof the corridor, staircases, storage rooms,aservices.In accordance to TGD Part B Document thefollowing should be included:60 Minute fire resistant doors for rooms withspecial precautions.60 Minute Fire rated walls (best practice wouldinclude Gyproc partitions).30 Minute fire resistant doors should beplaced in all the other rooms.
Fire exits should beclearly distinguishabe
Psychology17 m²
Lobby 5m²
FIRE EXIT
Pharmacy96 m²
38 Meters
Longest Travel Distance is: 38 MetersOTGA Room to East Staircase
A two way entrance system is provided for theentrance of the basement 6000mm wide, 3000mmwide for each carThe slope of the entrance must be of 1 in 10
30 FD
BookableRoom 23
m²
BookableRoom 28
m²
Circulation30 m²
SpeechTherapy17 m²
ChildHealth 18
m²
BookableRoom 18
m²
BookableRoom 15
m²
CleanersStorage10 m²
Circulation44 m²
Stairs 16m²
SoundProof
Room 16m²
ChildHealth 22
m²
SpeechTherapy13 m²
WoundClinic 28
m²
Circulation27 m²
ExaminationRoom 13
m²
WoundClinic 18
m²
MedicalStore 10
m²
BookableRoom 19
m²
BookableRoom 17
m²
CommunityWelfare30 m²
Store 6m²
FamilyRoom 30
m²
Reception& WaitingArea 78
m²
Restaurant89 m²
OTGARoom 51
m²
Care DocSuite 55
m² PhysioTreatment
93 m²
HSETreatmentRoom 55
m²
HSEOffice 14
m²Reception5 m²
Hall 12m²
HSEStore 11
m²
HSE DrRoom 28
m²
PrivateMedical
Suite 114m²
PrivateMedical
Suite 131m²
EXIT
EXIT
MAIN ENTRANCE
EXIT
EXIT
A clear unobstructed width of 1800mm should be consistanthtroughout the corridorA minimum clear unobstructed headroom should be 2400mmCorridor doors must be consistant with the corridor widthOther entrance doors are a minimum of 1000mm wide inaccordance with the TGD M documentThe radiators must be concealed in an inward opening of thewalls so they do not impede onto the circulation widths.
With a nett floor area per floor of greater than 200 m2 lift car dimensions shouldbe 2000 mm wide x 1400 mm deep. The larger lift car will facilitate most types ofwheelchairs; scooters and buggies, along with several other passengers;The controls in the lift car should be positioned at a height of not less than 900mm, not more than 1200 mm above the car floor and at least 500 mm from anyreturn wall. The call buttons at each landing should not be less than 900 mm andnot more than 1100 mm above the landing. Controls should not be located incorners and should be at least 500 mm from any wall or projecting surface.
The north staircase is accessible to all floors therefore thebasement area must be separated from the other floors in caseof fire, not to release smoke to other areasAmbulant disabled stairs have a riser of 175mm and a going of300mm, the width of the stairs is 1500mm, the headroom mustbe a minimum of 2400mm, handrails are present on each sideof the stairs at a height of 1000mmThere is a Refuge Space on the right side of the exit
Technical Guidance Document: Part B
Entrance areaThe width of the lobby should be wide enough to accommodate a wheelchair user of aminimum 1800mm x 1800mm turning circle. Edges of doors must be at least 300mm away fromthe wall to the door frame.Corridors and PassagewaysA minimum unobstructed width of 2000mm should be maintained throughout corridors andelements such as radiators and columns should not obstruct this width.A minimum clear unobstructed headroom should be 2100mm.Corridors must be adequately lit. Stair passageways should achieve an illuminace of 100 Luxper each floor.Vision PanelsVision panels supplied at corridors and stairs must comply with Table A4 Appendix A, TGDPart B. Vision panels will be fitted with sub-dividing and double swing doors within theproposed building and the size of the panel will be no less than 0.1m2 and the bottom panelwill be located not less than 900mm or more than 1500mm above floor level.Final ExitsAll exits are the same width or wider than the escape routes and give direct access to the openpassage. The widths of final exits should be adequate enough to support the expected amountof users during a case of fire.Basement staircase should be separated from the rest of the building encase of fire andsmoke entering the rest of the building up to second floor level.Sanitary FacilitiesWhere WC cubicles are provided there should be at least one ambulant disabled cubicle asper TGD Part M 1.4.6.1 and 1.4.6.2.In accordance to TGD M 1.1 to 1.3 Approach, access and circulation routes; accessiblesanitary facilities should be located in conveniently accessible parts of the building.Sanitary facilities should be clearly identified.In accordance to TGD M document part 1.3.3.2 door level handle ironmongery should beconstructed such as people with disabilities would be able to open them with a closed fist.Refreshment FacilitiesAccording to TGD Part M 1.3 all users should be able to access all parts of the building.Therefore all floor surfaces should be even and accessible.A wheelchair turning circle of 1800mm x 1800mm should be operable throughout.There should be accessible seating provided and self-serving area worktops should be nomore than 850mm high with a clear knee recess beneath of at least 700mm above floor level.StairsA clear width of 1200mm should be provided between up stands, enclosing walls and strings.The landing should be level and have an unobstructed area of 1500mm in width in ambulantdisabled stairs and a 1200mm wide unobstructed width elsewhere. The rise of flight betweeneach flight landing should not exceed 1800mm in height.All step nosings should incorporate a visually contrasting material on the thread.In accordance to TGD Part M section 1.1.3.6 a minimum unobstructed 1000mm heighthandrails on each flight of stairs should be consistent throughout all the stairs.The illuminance at each thread level should be at least 100 Lux.Sizes and tolerances of handrails should comply with BS 585: Part 1, workmanship should bein accordance to BS 1186: Part 2, and adhesives should comply with EN 204 type D3 or eitherD4.Aids to CommunicationAll outlets, switches, and controls that require precise hand movements should be locatedbetween 750mm and 1200mm above floor level.Pull chords for emergency alarm systems should be located as close as possible to the walland provide two red 50mm diameter bangles; one set at 100mm and other at 900mm abovefloor level.Socket outlets should be located consistently in relation to entrance doors with a minimum350mm away from door corners. Light switches for public use should be easily manoeuvrablewith large push pads within a height range from 900mm to 1200mm above floor level.Mains switches should be clearly indicated and should show if on or off according to TGD PartM section 1.6.4SignageSignage should be clearly indicated, especially for visually impaired. International symbols forentrances, exits, sanitary and other facilities should be used.In accordance to BS 9300: 2009 Visual signs should be designed with consideration to height,layout, font size and type, use of symbols and visual contrast with the background. Braillesignage should be located at 900mm to 1200mm above floor level.
Psychology17 m²
Pharmacy96 m²
Hall 17m²
Hall 20m²
Cubicles:The width of the cubicle should bebetween 800 mm and 900 mm andthe minimum length should be 1400 mm.Disabled WC:The width of the disabled wc should be 2500mm and lengthof 2500mmShould have a 1800mm x 1800mm wheelchair turningspace.Alarm pull chordVertical grab rail 480mm to 680mm highThe fixing height of horizontal rails to be the same as dropdown rails.All in accordance to TGD Part M Section 1.4 Diagram 16
Refuge space forambulant disabledusers
Exits and entrances should be clearlyidentifiable by using international signage
Main entrance should be clearlyidentified and stand out from therest of the buildingThere is a 1500mm footpath at themain entrance and all other exits inorder to connect to main footpaths.
EXIT
Restaurant fascilities should be accessible for allusersFloor surfaces should be even and accessible andslip resistantA wheelchair turning circle of 1800mm x 1800mmAccessible seating provided and self-serving areaworktops should be no more than 850mm high witha clear knee recess beneath of at least 700mmabove floor level.
A two way entrance system isprovided for the entrance of thebasement 6000mm wide,3000mm wide for each carThe slope of the entrance mustbe of 1 in 10
Nominal stairs runfrom the basementthroughout all thestoreys of thebuilding
Lobby 15m²
Stairs 21m²
Circulation
Refuge Space
1800mm x 1800mmWheelchair Turning Circle
All floor surfaces must beslip resistant and haveedge trims as indicated inthe drawings
PVC CONCAVE EDGE TRIM
The MTrim Concave Edge Trim can be used tocover uneven edges between wall and wallinternal corners. When used in conjunctionwith silicone the concave edge trim seals thesurface, provided there is no movementexperienced. The silicone is placed on theinside of the trim between the tile and trim andbetween the underside of the concave trim andthe surface that it rests on.
Must be used in conjunction to all floors.
Sealant
Edge Trim Strip
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology CarlowBSc. in Architectural Technology
Year 3 2015-2016
As indicated
25/0
4/2
016 0
3:4
2:0
5
Ground Floor Building Regulations
3
Primary Care Center
April 2016
Rasmante Sedleckaite
Dan O'Sullivan/ Noel Dunne/Mark Duffy
A109
1 : 200
Ground Floor Level TGD B1
1 : 200
Ground Floor Level TGD M2
1 : 5
Floor Edge trim3
1 : 1
Edge trim4