Greenair GAV-M5Series
~INTERNATIONAL
VRF ALL DC INVERTER ,r c::~~AIR CONDITIONING SYSTEM ----
GreenairINTERNATIONAL
OverviewVRF Air Conditioner has a number of key technologies which improve performance and save energy.All DC GAV-M5 outdoor units achieve capacity of 72HP with the industry's top class energy efficiencyof cooling and heating. It supports an incredible piping length of 200m and a longer level differenceof 11Om,with overall system piping networkof 1OOOmmaking it perfect for big-sizedand high-risebuildingsfor wide application.
Ill111.•••111
• ~ ·· ,. :_- -· ·I 1!!!!::1- =: ;- I 1111!1~1; - ~ 111111•111,111·
•· GAV-M5 •. ~.:.__--:::.::== :iilll!I '·;::...:::: 1~~11: -=:;: 'I'~~·::::=..==;-==== Ii~~ = ;- =-== I"~"!::::-,...;.f I~'::._~ ;:·_:-= ,~ . - ;:-::::: I~~i.,
GAV-M5
Contents~03 Nomenclature& Line Up
~05 GAVFeatures
~13 Outdoor Units Lineup
~17 Indoor Units Lineup
~44 HeatRecoveryVentilator
~48 Control System &Accessories
GreenairINTERNATIONAL
Green Air NomenclatureOUTDOOR UNIT
Design Code (MS-CS)
Refrigerant typeR410A (Standard)
Reversible (omit for cool only)
D:DCFanMotorA:AC FanMotorOutdoor UnitR:380-415V, 50Hz, 3PH (Standard)Cooling capacity (X 100W)Inverter
INDOOR UNIT
Green Air
Design Code (MS-CS)
Refrigerant typeR410A (Standard)
Motor typeD: DC fan motor A: AC fan motor
Indoor Unit Structural CategoryCK4: Standard four way cassetteCKA: Compact four way cassetteCK1: One way cassetteCK2: Two way cassetteCC1: High static Pressure DuctCC2: Medium static Pressure DuctCC3: Low static Pressure DuctCF: Ceiling & floor typeWM: Wall mounted typeFS: Floor standingFA: Fresh Air
Cooling capacity (X 100W)
Inverter
Green Air
•
GAV-M5
Line Up Models WIDE APPLICATION RANGE
Large capacity for big sized building
8, 10HP 12, 14, 16HP 18HP 18,20,22,24,26,28,30,32HP
The outdoor units capacity ranges from 8HP up to 72HP in 2HP increment. Maximum 64 indoor units withcapacity up to 130% of total outdoor units can be connected in one refrigeration system.
- ,jl,,Jli"lll
II.I- 1111
·B f' ..I
·-··-
34,36, 38, 40, 42, 44, 46, 48HP 50,52,54,56,58,60,62,64HP
- - -I
"'~ · 1111
Iii-
11t-.·B
66, 68, 70, 72HP
= ~ .. GAVMo • ·§ ~ •~11: •• GAVMo • ": ~ ;: "" a•• GAV.~ • •;o ~ § "
~ ~·- .... _ .. --- .. ··- ..· .
" '~~~~
70
lS
64;g~
./_,,,.,..'6./
39~.. ~~
<C~
2Q~
/•"
More connectable indoor units. 6S
60
SS
The high number of connectable units issuitable for large buildingsand projects.
so
4S
40
3S
30
2S
20
10
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I00 0 N ~ ~ 00 0 N ~ ~ 00 0 N ~ ~ 00 0 N ~ ~ 00 0 N ~ ~ 00 0 N ~ ~ 00 0 N
rl rl rl rl rl N N N N N m m m m m ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
•
GreenairINTERNATIONAL
FeaturesHIGH EFFICIENCYGAV-M5with high efficiency DC compressors, DC motors and high efficient heat exchanger, achievethe world's Top Class energy efficiency. The cooling EER up to 4.29 and the heatingCOP up to 4.39
High EER/COP valuesEER COP
8HP lOHP
4.17 4.17 4.02 3.893.91
12HP 8HP 16HP 18HP16HP 18HP lOHP 12HP 14HP14HP
All DC inverter compressorsVRF Air Conditioner achieves the industry's top class energy efficiency of cooling EER and heating COP byutilizing the Brushless Reluctance DC compressor control, improved performance heat exchanger by innovativedesign and numerous high performance key parts. High efficiency DC inverter compressor reduces powerconsumption by 25%.8HP and 10HP models are equipped with one DC inverter compressor and 12, 14, 16, 18HP models areequippedwith two.DC inverter compressors enable the GAV-M5to offer a wide operation range from 20Hz to 200Hz andraise IPLV considerably.
New structure enhancesmid-frequencyperformanceSpecially designedscroll profile for R41OA
More compact,weight reduced by 50%
Advance!permanentmagnet DC motor improveslow frequency band performance
Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume.Wide operation range from 20Hz to 200Hz.
Compressor efficiency
~:Ic
Centralizingwinding '1:1GIGICl.
8I/). I
~fcGI·;:;
=wDistributingwinding 20 40 60
• New DC motor-centralizedwinding
• Common DC motor-distributingwinding
Rotor speed(s-1)80 100
•
GAV-M5
All DC fan motorsAccording to the running load and pressure, it controls the speed of DC fan to achieve the min. powerconsumption.
• Used across entire range ofmodels (from 8 to 72 HP).
•Efficiency improvement by upto 45% especially at low speed.
•Wide speed adjustment with18 steps vector control.
MOTOR SPEED (RPM)
Speedcontrol
~- - - - - - - _ _tii~h-- - - - - - -
------------------------------------- ~--------18 Step Vector Control ~
Low
High performance heat exchangerNew design Original design
Windage& air flowij 0.8
g 0.8
~j; OA
~i 0.2
ii!
~. Original ~esign- "".New design
Frost contrail•Hydrophilicfins + inner-threaded pipes
• The newly designedwindow fins enlarge the heat-exchangingarea , decreasethe air resistance,save more power andenhanceheatexchangeperformance.
• Hydrophilicfins and inner-threadedcopperpipesoptimizeheatexchangeefficiency.
Original design
- : Liquid
~:~Ill~~~111 1·Gas:· a11°c11111' • ~I (98:8°F)New design - 43•c
~-Liquid (109.4°F)
•1i1J:..-•I 1::;~)Gas:,----75°C I~.~-1•(167°F)
Gas:[ Gas Gas-Liquid --LiquidWJllB i':'~Im -·.~,.laM-Increased hot liquid rate in the condenser
Improved heat-exchangeefficiency
• Innovatively designed high efficiency heat exchanger, which can reach up to 12°Csubcooling degree, reduces thesystem resistance and improves reliability.
• When the outdoor temperature is 35°C, the refrigerant can be cooled down to 37.1°C, thus achieving highheat-exchangingefficiencywith only 2.1°C temperature difference.•
GreenairINTERNATIONAL
Fan grille
Optimized fan blade shape withImproved air outlet grille enhancesair volume which greatly improvesfan performance and decreasesnoise.Also, a higher external staticpressure has been achievedoptionally from 20 Pa to 40 Pa.(60Pa is available for 12HP)
Improved fan blade profileA new blade with sharp edges and a slight curve increasesthe airflow rate and lowers vibration and airflow resistance.
Wide operation range
: COOLING MOOE 52°C
IIIIII
HEATING MODE
-20 -10 0 10 20 30 40 50 60Outdoor temp. 0C(D.B.)
The GAV-M5 system operates stably at extreme temperatures ranging from minus 20°C to 52°C .
•
GAV-M5
Simple signal line connectionInstallation is easier as communication wiring can be shared by indoor & outdoor units. It's easy for theuser to retrofit the existing system with a centralized control by simply connecting to the outdoor units.
- • PQE & XYE: only one set of PQE communication wires canachieve communication among indoor units, outdoor units andthe network.
• Reversible communication, central controller can be connectedfrom indoor or outdoor as desired.
PIOIEI~ ~
~---------[flQ]!]
Auto addressing
• The outdoor unit can automatically assign the addresses to indoor units without any manual settings.
• Wireless controller can query and modify each indoor unit's address.
AutomaticallyIdentify
Compact design for effective use of spaceEasy to transport
Compact size and light weight design minimizes theinstallation footprint, reduces the installation floor load,and is easier for transportation. For some projects theunits can even be transported through the elevator orforklift, reduce access problem at the jobsite .
•
GreenairINTERNATIONAL
Long piping length
The solution supports an incredible piping length of 1,000m andlevel difference of 110m, making it perfect for large projects.
Pipinglength 175m
E~-
l!)~ ~
~-~
J:: ~--~°'c~ ~ 0
ro I -·:J
~;__~ti"'oc0:0:E:JE·x"'2
Totalpipe length'(Actual) 1000m
Actual lengthMaximumpiping(L)
Equivalent length 200m
Piping (The farthest IOUfrom the first Indoorunitbranch)equivalent length
40m/90m'
Outdoor unit up ?OmLevel differenceLevel
difference 110mbetweenIDU-ODU Outdoor unit down
Level difference between IDU-IDU 30m
*Total pipe length is equal to two times - pipe length plus - pipe length."Whenthe farthestpipe length is morethan 40m. It needsto meet the specificconditionaccording to the installation part of the technical manual.
• The first indoorunit branch
Extra high static pressure - Max. 60 Pa and air volume increased by 10%
The high-static pressure propeller and optimized fan guard can adapt to variousinstallation environments.GreenAir now offers up to 40 Pa* external static pressure units for customizedapplications (60 Pa is available for the 12HP model). A standard 0-20Pa functionis equipped by default.*You need to consult GreenAir if you require over 40Pa.
HIGHER RELIABILITYDuty cyclingIn one combination, any outdoor unit can run as the master outdoor unit to equalize the service life of allunits.
Master Slave 1 Slave 2--------- --------- ---------
12HP-18HP models with two compressors have an alternative duty cycle function .
•
GAV-M5
Back-up function
In a multiple system, when the master unit fails, any single unit can be set as the master unit, then theremaining units can keep on working. This can be set on PCB by DIP switches at site.
Master Slave1--~1 · =MMOti ~.
••If.... •. . ~11.•..•. - · 1111
.,1~1.~~"··(
Slave2
r I Iii!1
_ I Ill! ~ When the slave 1 failedand came into standbystate, the left modulecan still work .
ENHANCED COMFORTNight silent operation modeGreenAir Night Silent Mode feature which is easily set on the PCB allows the unit to be set to various timeoptions during Non Peak and Peak operation time optimizing the units noise output.Super silent operation mode can reduce sound level further up to minimum 45dB (A).Night silent operation will be activated X hours after the peak temperature during daytime, and it will go backto normal operation after Y hours.
-Model 1-+X: 6 hours,Y: 10 hours-Model 3-+X: 6 hours,Y: 12 hours
~ ~0:>,• Peak val.•..•
·c:; 100ctla.ctlo
-Model 2-+X: 8 hours,Y: 10 hours-Model 4-+X: 8 hours,Y: 8 hours
-g 500...J
al"C •Cl) noiseIll'sz
08:00 14:00 22:00 08:00
Notes:This function can be activated by setting at site. Temperature(load) curve shown in the graph is just an example .
•
GreenairINTERNATIONAL
Double EEV control technologyDouble EEV Control Technology in onesystem, each EEV part achieves 480 pulsesto adjust flow precisely. Ensures thetemperature-control precisely and steadilyto provide a comfortable environment.
High efficiency oil balance and oil return technology
• Oil balance pipes among modules andindividual oil balance by vector controlensure even oil distribution among themodules which keeps compressorsrunning normally.
• High efficiency centrifugal oil separator(separation efficiency up to 99%)oil seperates from discharge gas and gobackto compressors. ~I0-11-eve-n-pi-pe-I
•Auto oil return program monitors therunning time and status of the system,ensures reliable oil return.
Intelligent soft start technologyDC inverter compressor soft start function reduces strike to theelectric network. This kind of high-performance and low sound scrollcompressor operates at a faster rate when starting, reducing start-uptime. It also helps the unit to quickly achieve the room temperatureto the set level.
Quick warm-up & cool-down design
Starting current(%
600
500
400
300
200
100
- Directstart-Y-l::;.start- Start by inverter
Comparison of start by inverter and bytraditionalmettlods
Fluctuation of room temperature
123
• By utilizing the benefits of the inverter compressor, thesystem can reach full load quickly and shorten thewarm-up and cool-down times to provide an immediateand comfortable air solution.
• Less temperature fluctuation will create a better livingenvironment. Cooling operation • Inverter • Non-inverter
•
GAV-M5
Intelligent defrosting raises heat capacity
~.....-"""....~~=j :::::i:::::s:::~=! ':::-11.117-li!1.4741.4741.4741.47
..g,47-1111.47
Time(Min)
Test Drawing:Common Defrost Heating 50mln,dafrost 1Omln
RapIdlydefrosting
Time(Min)
EASIER INSTALLATION AND SERVICEEasy access
* Rotating Control box is available for 18HPmodelwhichwith G-shapeCondenser.
Newly designed rotating control box is so excellent that it canrotate in a wide angle. It is convenient for inspection and maintenance of the pipeline system and greatly reduces the time ofdismount the electric control box.
r:r.I r:r.I1:1:11:1:1
Reserved checking window onelectric control box for convenientspot checking and status enquiry.
Self-diagnosis function helps service engineerslocate faults quickly and easily.
Smooth 180° sine wave DC InverterAdaptingthe 180°SineWave Inverterto smoothmotor rotationgreatly improvesoperatingefficiencycomparedwith traditionalsawtoothwave.
,.. 11. ...-1-...- -•• --.. ~ '\.., ••• --- ""-Common Sawtooth Wave
r: ~, ~r ', "' , ...•...
'" / ...•
'-.. ~
180°SineWaveDeinverter
•
GreenairINTERNATIONAL
Prime ModelsCapacity
HP 8 10 12 14 16 18
RangeKW 25.2 28.0 33.5 40.0 45.0 50.0
...I
J
~j"""' I"l]Appearance c:: - " ~ II~ ...•- - 11·
~B - l'JEl., -.-.. -
Combination Table
ALL DC INVERTERGAV Series - Outdoor Combinations
GREEN AIR MODEL GAV COOLING HEATINGMaximum#of
Total# of Total#ofOUTDOOR UNIT COMBINATION
SR.NO.Series
HPCAPACITY KW CAPACITY KW
connectableoutdoor units
indoor unitscompressors SHP lOHP 12HP 14HP 16HP 18 HP
1 GAV-2S2 DRS-MS 8 2S.2 27 13 1 1 12 GAV-280 DRS-MS 10 28 31.S 16 1 1 13 GAV-33S DRS-MS 12 33.S 37.S 20 2 1 14 GAV-400 DRS-MS 14 40 4S 23 2 1 1s GAV-4SO DRS-MS 16 4S so 26 2 1 16 GAV-SOODRS-MS 18 so S6 29 2 1 1
7 GAV-S60 DRS-MS 20 S6 63 33 2 2 28 GAV-61S DRS-MS 22 61.S 69 36 3 2 1 19 GAV-680 DRS-MS 24 68 76.S 39 3 2 1 110 GAV-730 DRS-MS 26 73 81.S 43 3 2 1 111 GAV-800 DRS-MS 28 80 90 46 4 2 212 GAV-8SO DRS-MS 30 8S 9S so 4 2 1 113 GAV-900 DRS-MS 32 90 100 S3 4 2 214 GAV-9SO DRS-MS 34 9S 106 S6 4 2 1 1lS GAV-1000 DRS-MS 36 100 112 S9 4 2 216 GAV-106S DRS-MS 38 106.S 119 63 s 3 1 1 117 GAV-1130 DRS-MS 40 113 126.S 64 s 3 1 1 118 GAV-1200 DRS-MS 42 120 13S 64 6 3 319 GAV-12SO DRS-MS 44 12S 140 64 6 3 2 120 GAV-1300 DRS-MS 46 130 14S 64 6 3 1 221 GAV-13SO DRS-MS 48 13S lSO 64 6 3 322 GAV-1400 DRS-MS so 140 1S6 64 6 3 2 123 GAV-14SO DRS-MS S2 14S 162 64 6 3 1 224 GAV-lSOO DRS-MS S4 lSO 168 64 6 3 32S GAV-1S80 DRS-MS S6 1S8 176.S 64 7 4 1 1 226 GAV-1630 DRS-MS S8 163 181.S 64 7 4 1 327 GAV-1700 DRS-MS 60 170 190 64 8 4 2 228 GAV-17SO DRS-MS 62 17S 19S 64 8 4 1 329 GAV-1800 DRS-MS 64 180 200 64 8 4 430 GAV-18SO DRS-MS 66 18S 206 64 8 4 3 131 GAV-1900 DRS-MS 68 190 212 64 8 4 2 232 GAV-19SO DRS-MS 70 19S 218 64 8 4 1 333 GAV-2000 DRS-MS 72 200 224 64 8 4 4
•
Dimensions
GAV-M5
I: I c:ll)-
l!)
co
960
Unit: mm
0
q:_
• Position illustration of screw bolts (Unit: mm)
736
960830
765
15x23 long U-shape hole
• t • t
' I I I I' • t • t
:· :.E:j~ . • t
'.) I I I I (
ioco
1250
iocor-;
Unit: mm
I)
...: ~
• Position illustration of screw bolts (Unit: mm)
•
736
1250
765
1120
15x23 long U-shape hole
GreenairINTERNATIONAL
Outdoor Unit
GAV - M5 Series -B r ..,
l~Ilj,fl -
J~'M> · [ni
Iii11·r
r' ..
Specifications
Model
Power source V-Ph-Hz---kWc,..,,(N~'"~Btu/h
Cooling Mode kcal/h
Power input kW
EER
kWc-•-'"'J Btu/h
Heating Mode kcal/h
Power input kW
COP --Total capacity %
Indoor unit connectable Max. quantity of indoor unitsSound pressure level dB(A)
Liquid line pipe
~
mm
Refrigerant piping diameter Gas pipe mm
Oil balance pipe mm
Type --Quantity
Airflow rate t m3ih
CFMFan Dimension(Dia. xl-l) mm
Vane Quantities of each blower
DC inverter Compressor
Motor output kW
ESP _l Pa
QuantityCapacity i wRefrigerant oil ml
mm
mm
The farthest Jlipe length m
Max. heightdiffernce m
J}'.!Je _JOriginal charge kg
kg
Net dimension(WxHxD)
Packing dimension(WxHxD)
Pipe connection
Refrigerant charge
Net/Gross weight
Notes:1.Nominal conditions
IndoorCoolingHeating
GAV - 252 DR 5 - M5
25.2
86,000
21_,_703
5.875
4.29
27
~100
~253
6.15
4.39
50-130
13
57
<1>12.7<1>25.4<1>6.4
Axial propeller
GAV - 280 DR 5 - M5
380-415/3/50
28
95,500
24_,_115
7.053
3.97
31.5
107,500
___E,_1297.554
4.17
50-130
16
57
<1>12.7<1>25.4<1>6.4
AxiaLprqpel ler
---112±2____M_11_700x202
30.75
0-20 (default)
GAV - 335 DR 5 - M5
33.5
114,300
28_,_852
8.793
3.81
37.5
128,000
__B,297
8.993
4.17
50-130
20
59
<1>15.9<1>31.8<1>6.4
Axial propeller
1+1
---1.M2Q__~560x189
3+4
0.56+0.38
0-20 (default)
--+----112R_____M_11_700x202
30.75
0-20(def~
~500
20-40 (can be customi~ 20-40 (can be customiz~20-60 (can becustomiz~
1 1 1+1
960x 1,615x 765
1,025x1,790x830
200 200
110 ± 110
R410A R410A10 10
212/227 212/227
27°C DB(80.6.:£.1...!9°C WB(66.2.:£.L 35°C DB(95°F)20°C DB(68°F2,_!_5°CWB(59°FL re DB(44.6°FL
Outdoor Pipe length7.5m7.5m
2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor.3.Due to continued product improvements, the above specifications may change without prior notice .
•
31,590+11,800
500+500
1,250x1,615x765
1_,_305x1_,_790x820
200
110
R410A
12
288/308
Level differenceOmOm
Outdoor Unit
GAV - M5 Series -·B
GAV-M5
·-··I. 1~111JI
IJ~11... 1••'~
Specifications
Model
Power source V-Ph-Hz--kW
Capacity (Nominal) Btu/h
Cooling Mode kcal/h
Power input kW
EER
kW
Capacity (Nominal) Btu/h
Heating Mode kcal/h
Power input kW
COP
Total capacity %Indoor unit connectable Max. quantity of indoor unitsSound pressure level dB(A)
Liquid line pipe mm- --- --
Refrigerant piping diameter Gas pipe mm
Oil balance pipe mm
TypeQuantity ---Airflow rate m3/h
CFMFan Dimension(Dia. xH) mm
Vane Quantities of each blowerMotor output kW
ESP Pa
QuantityDC inverter Compressor Capacity w---
Refrigerant oil ml--Net dimension(WxHxD) mm
Packing dimension(WxHxD) mm
Pipe connection The farthest pipe length m
Max. height differnce m
Refrigerant charge TypeOriginal charge kg
- --NeUGross weight kg
Notes:1.Nominal conditions
GAV - 400 DR 5 - M5
40
136,500
34,450
11.299
3.54
45
153,500
38,756
11.194
4.02
50-130
23
61
<1>15.9<1>31.8<1>6.4
Axial propeller
1+1
15_,_620
9,185560x189
3+4
0.56+0.38
0-20 (defaultL_
20-40 (can be customizedL
1+1
GAV - 450 DR 5 - M5
380-415/3/50
45
153,5
38_,_75
13.25
3.4
50
170,6
43 06~
12.7
3.91
50-13
26
62
<1>15.<1>31.<1>6.4
....8xlalp.r:o
1+1
~~560x1
3+4
0.56+0
0-20 (defa'd!!L_
)0
Le.L- _ ~- ,...._
r GAV - 500 DR 5 - M5
50
170,500
43_,_063
14.793
3.38
56
190,960
48 230
14.396
3.89
50-130
29
62
<1>19.1<!>31.8<1>6.4
....8xlalpLQpelle.L- _
1+1
~~
560x189
3+4
0.56+0.38
0-20 (defa'd!!L
20-40 (can be customiz~ 20-40 (can be customiz~
1+1 1+1
31,590+11_,_800 ±- 31,590+11,800 ± 31,590+11,800
500+500 500+500 500+5001,250x 1,615x7651,305x 1,790x820
200 l- 200
+200
110 110 110R410A R410A R410A
15 15 17
288/308 288/308 310/330
CoolingHeating
Indoor27'C DB(80.6'F~9'C WB(66.2'FL20'C DB(68'F), 15'C WB(59'F)
Outdoor35'C DB(95'FLre DB(44.6'F)
Pipe length7.5m7.5m
2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor.4.Due to continued product improvements, the above specifications may change without prior notice .
•
Level differenceOmOm
GreenairINTERNATIONAL
GAV-M5
Indoor Units LineupOne-way Cassette
Two-way Cassette
Compact Four-way Cassette
Four-way Cassette
Low Static Ducted Unit
Medium Static Ducted Unit
High Static Ducted Unit
Ceiling & Floor Type Unit
Wall-mounted Unit
Floor Standing Type
Fresh Air processing Unit
Heat Recovery Unit
•
GreenairINTERNATIONAL
ModelType 18 22 28
(capacity •100)
One-way GAV-XX-CK1-D5-M5 ~cassette
Two-way GAV - XX - CK2 - D5 - M5~ 0 0cassette ..-.
Compact four- GAV - XX - CKA- D5 - M5~ () ()way cassette
Four-way I GAV - XX - CK4 - D5 - M5 I ~
Iocassette I
I I ' 0 o oLow Static Pressure Duct GAV-XX-CC3-D5-M5
I GAV-XX-CC2-D5-M5 I n I e eMedium Static Pressure Duct
High StaticPressure Duct GAV-XX-CC1-D5-M5
Ceiling & Floor
IGAV - XX - CF - D5 - M5
I IType
~ - 0 0
I I IWall Mounted GAV - XX - WM - D5 - M5 o 0
()0Floor Standing GAV - XX - FS - D5 - M5
Fresh Airprocessing unit GAV - XX - FA- D5 - M5
11 types and more than 100 models are available to meet varied customer requirements .
•
GAV-M5
36 45 56 71 80 90 100 112 125 140 160 200 250 280 400 450 560
e e e0 0 0 0
0 ()
0 0 0 () 0 c 0 c0 o ()
e e e e e ec 0 e ()
0 0
0 e e
0 0 0
0 0 0 0 0 e 0 0 0
0 0 0
0 0 0
o 0 e0 0 0
0 0 () c 0
0 0
e e e
GreenairINTERNATIONAL
One Way Cassette
~- __..--/
Only 153mm thicknessCompact design, ultra slim body with a minimum thickness of153mm for model 18-36 especially suitable for narrow ceilings,such as in lobbies and small meeting rooms.
_I 1'53~ IUI~ mo
Standard built-in drain pump with 750mm pump head.
Auto Restart Fresh Air
Auto Addressing Cleanable Panel
Follow Me Anti-Cold Air Function
Super High Air FlowLED Display
Auto swing
Acetaldehyde'@' '',- .. -...,;\:·.~·---,-;-;,~
Auto swing mechanism guarantees evenairflow distribution and a better roomtemperature balance.
Single-flow design suitscorner installation
Cooling
Fresh air, improved air quality
Reserved fresh air intake port for high quality aircreates a comfortable and healthy environment.
Special enzyme sterilization and filtering technologiesfilter bacteria, smog, and pollen. Provide a clean,healthy and natural air supply.
••
Acetic acid Formal
GAV-M5
Model GAV-28-CK1-D5-M5I
GAV-36-CK1-D5-M5I
GAV-45-CK1-D5-M5I
GAV-56-CK1-D5-M5
Power supply 1-phase, 220-240V, 50Hz
kW 2.8 3.6 4.5 5.6
Cooling capacity kcal/h 2,400 3,100 3,800 4,800
Btu/h 9,500 12,200 15,300 19,100
kW 3.2 4.0 5.0 6.3
Heating capacity kcal/h 2,700 3,400 4,300 5,400
Btu/h 10,900 13,600 17,000 21,500
Cooling 41 41 80 85
Power input wHeating 41 41 80 85
Cooling 0.25 0.25 0.37 0.39Rated current A
Heating 0.25 0.25 0.37 0.39
m3/h 573/456/315 704/630/503 860/810/702Airflow rate(H/M/L)
CFM 337/268/185 414/370/296 506/476/413
Sound level dB(A) 39/37/34 40/38/34 41/39/35 42/40/36
Type R410A
RefrigerantControl method EXV
Net dim.(WxHxD) 1054x169x425 1147x200x640mm
Body Gross dim.(WxHxD) 1155x245x490 1380x265x775
Net/gross kg 13/16.5 31.5/37.2
Net dim.(WxHxD) 1180x36.5x465 1425x1 Ox755mm
Panel Gross dim.(WxHxD) 1232x107x517 1500x11Ox870
Net/gross kg 3.5/5.2 9/12
L(flare) mm <!>6.35 <!>6.35 <!>6.35 <!>9.53
PipingG(flare) <!>12.7 <!>12.7 <!>12.7 <!>15.9mm
connections
Drain piping mm OD<t>16 OD<t>16 OD<t>16 OD<t>16
Pump head mm 750 750 750 750
Standard Controller Wireless remote controller (RM05/BG(T)E-A/E)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27'CDB, 19'cwb,outdoor temp.:35'CDB, equivalent ref. Piping: 8m(horizontal)2. Nominal heating capacities are based on the following conditions: return air temp.: 20'CDB,outdoor temp.: 7'CDB, 6'CWB,equivalent ref. Piping: 8m(horizontal)3. Sound level is measured at 1m below the unit.
GreenairINTERNATIONAL
Two Way CassetteAuto Restart FreshAir
Auto Addressing CleanablePanel
Anti-ColdAir FunctionFollowMe
SuperHighAir FlowLEDDisplay
Quiet operation High airflow
Optimized airflow duct with low resistance greatly High airflow for high ceiling applicationguaran-reduces noise, down to 24 dB(A). tees comfort in large space. It makes every
person in the room get even distribution ofairflow and temperature.Stylish design and slim body
Thanks to the stylish appearanceand slim body, theunit suits any room's decor and ambience. At only300 mm high, the unit requires only a smallsuspended ceiling space. Installation has no heightlimitations, which makes overall design featuresmuchmore flexible.
- - - - - -~ 1--- - --r:~~~---------r--r=~-----~~~~~~~====?
Standardbuilt-indrainpumpwith 750mmpumphead(higherpumpheadcanbe customized).
Flat-typesuction grille design greatly simplifiesmaintenancework.
GAV-M5
Model GAV-22-CK2-D5-M5 GAV-28-CK2-D5-M5 GAV-36-CK2-D5-M5 GAV-45-CK2-D5-M5 GAV-56-CK2-D5-M5GAV-71-CK2-D5-M5
Power supply 1-phase, 220-240V, 50Hz
kW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling capacity kcal/h 1,900 2,400 3,100 3,800 4,800 6,100
Btu/h 7,500 9,500 12,200 15,300 19,100 24,200
kW 2.6 3.2 4.0 5.0 6.3 8.0
Heating capacity kcal/h 2,200 2,700 3,400 4,300 5,400 6,800
Btu/h 8,900 10,900 13,600 17,000 21,500 27,300
Cooling 57 57 60 92 108 154
Power input wHeating 57 57 60 92 108 154
Cooling 0.35 0.45 0.45 0.55 0.55 0.75
Rated current AHeating 0.35 0.45 0.45 0.55 0.55 0.75
m3/h 654/530/410 654/530/410 725/591/458 850/670/550 980/800/670 1,20011,ooon10
Airflow rate(H/M/L)
CFM 385/3121241 385/3121241 427 /348/270 500/394/324 577 /4 71/394 706/589/453
Sound level dB(A) 33/29/24 36/32129 36/32129 39/35/30 39/35/30 44/40/34
Type R410A
RefrigerantControl method EXV
Net dim.(WxHxD) 1,172x300x592 1,172x300x592 1,172x300x592 1,172x300x592 1,172x300x592 1,172x300x592mm
Body Gross dim.(WxHxD) 1,355x400x675 1,355x400x675 1,355x400x675 1,355x400x675 1,355x400x675 1,355x400x675
Net/gross kg 34/42.5 34/42.5 34/42.5 36.5/45 36.5/45 36.5/45
Net dim.(WxHxD) 1,430x90x680 1,430x90x680 1,430x90x680 1,430x90x680 1,430x90x680 1,430x90x680mm
Panel Gross dim.(WxHxD) 1,525x130x765 1,525x130x765 1,525x130x765 1,525x130x765 1,525x130x765 1,525x130x765
Net/gross kg 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15
L(flare) mm Cl>6.35 Cl>6.35 Cl>6.35 Cl>6.35 Cl>9.53 Cl>9.53
Piping G(flare) Cl>12.7 Cl>12.7 Cl>12.7 Cl>12.7 Cl>15.9 Cl>15.9mmconnections
Drain piping mm ID Cl>25,OD Cl>32 ID <1>25,OD <1>32 ID <1>25,OD <1>32 ID <1>25,OD <1>32 ID <1>25,OD <1>32 ID <1>25,OD <1>32
Pump head mm 750 750 750 750 750 750
Standard Controller - Wireless remote controller (RM05/BG(T)-A)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB, 19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal)2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal)3. Sound level is measured at 1.4m below the unit.
~- __..--/
GreenairINTERNATIONAL
Compact Four Way Cassette
Auto Restart Fresh Air
Auto Addressing Cleanable Panel
Follow Me Anti-Cold Air Function
Built-in DrainPump LED Display
Super High Air Flow
Compact design, easy installation and maintenance
Quiet operation, gentle air supply
k-----i~Diffuser
!I' • 3-D spiralfan blade
Streamline plate ensures quiet operationAdvanced 3-D spiral fan design reduces airresistance and operation noise.
360°Airflow outlet360° air outlet provides strongair flow circulation to cool orheat every corner of a roomand evenly distributetemperature.
Extremely compact casing suits any room's decor andrequires little space for installation on a low ceiling. Dueto the compact body and light weight, all models can beinstalled without a hoist.
Four-way uniform airflow
Four air discharge ports provide strong aircirculation to cool or heat every corner of a room andevenly distribute temperature. High airflow mode canmaximize the conditioning effect in rooms that are over3m high.
Lift pump
Drain pump with a 500mm pumphead is fitted asstandard; maximum 600mm pumphead is available.
GAV-M5
Model GAV-22-CKA-D5-M5 GAV-28-CKA-D5-M5 GAV-36-CKA-D5-M5 GAV-45-CKA-D5-M5
Power supply 1-phase,220-240V,50Hz
kW 2.2 2.8 3.6 4.5
Cooling capacity kcal/h 1,900 2,400 3,100 3,800
Btu/h 7,500 9,500 12,200 15,300
kW 2.4 3.2 4.0 5.0
Heating capacity kcal/h 2,000 2,700 3,400 4,300
Btu/h 8,900 10,900 13,600 17,000
Cooling 51 52 58 58Power input w
Heating 43 44 50 51
Cooling 0.175 0.175 0.21 0.21Rated current A
Heating 0.175 0.175 0.21 0.21
m3/h 522/414/313 520/415/320 610/521/409 610/521/409Airflow rate(H/M/L)
CFM 307/244/184 306/200/188 359/306/241 359/306/241
Sound level dB(A) 35.8/33.4/23.4 35.8/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8
Type R410A
RefrigerantControl method EXV
Netdim.(WxHxD) 570x260x570 570x260x570 570x260x570 570x260x570mm
Body Grossdim.(WxHxD) 675x285x675 675x285x675 675x285x675 675x285x675
Net/gross kg 17.5/22 17.5/22 19/23.5 19/23.5
Netdim.(WxHxD) 647x50x647 647x50x647 647x50x647 647x50x647mm
Panel Grossdim.(WxHxD) 705x113x705 705x113x705 705x113x705 705x113x705
Net/gross kg 3/5 3/5 3/5 3/5
L(flare) mm <1>6.35 <1>6.35 <1>6.35 <1>6.35
Piping G(flare) <1>12.7 <1>12.7 <1>12.7 <1>12.7mmconnections
Drain piping mm ID <1>20ODC!>25 IDC!>20 ODC!>25 ID <1>20ODC!>25 IDC!>20 ODC!>25
Pumphead mm 500 500 500 500
StandardController - Wireless remote controller (RM05/BG(T)E-A)
Notes:
1. Nominal cooling capacitiesare basedon the following conditions: return air temp. : 27°CDB,19'CWB,outdoor temp.:35'CDB, equivalent ref. Piping:8m(horizontal)2. Nominal heatingcapacitiesare basedon the following conditions: return air temp : 20'CDB,outdoor temp.: ?'CDB, 6°CWB,equivalentref. Piping:8m(horizontal)3. Sound level is measuredat 1.4mbelowthe unit.
GreenairINTERNATIONAL
Four Way Cassette
Auto Restart Fresh Air
Auto Addressing Cleanable Panel
Follow Me Anti-Cold Air Function
Built-in Drain Pump LED Display
"----- ~
Quiet operation, gentle air supply• Streamline plate ensures quiet operation.• Advanced 3-D spiral fan design reduces airresistance and operation noise.
Easy troubleshootingBy adding digital tube on the display board, ErrorCodes can be displayed directly for troubleshooting.
360°Airflow outlet
360° air outlet providesstrong air circulation tocool or heat every corner of aroom and evenly distributetemperature.
Super High Air Flow
Four-stage fan speed
Four-way uniform air flowFour air discharge ports provide strong aircirculation to cool or heat every corner of a roomand evenly distribute temperature. High airflowmode can maximize the conditioning effect inrooms that are over 3m high.
Reserved multi-function ports
~
Toanotherroom o•• ~()Fresh Air Intake ====For ductconrecting / .c:/
High lift pumpDrain pump can take condenser water up to750mm, which simplifies installation of the drainpiping system.
Ultra-thin machine body (minimum height230mm) simplifies installation and maintenance.
GAV-M5
Model GAV-28-CK4-05-M5I
GAV-36-CK4-05-M5I
GAV-45-CK4-05-M5I
GAV-56-CK4-05-M5I
GAV-71-CK4-05-M5
Power supply 1-phase,220-240V,50Hz
kW 2.8 3.6 4.5 5.6 7.1Cooling capacity kcal/h 2,400 3,100 3,800 4,800 6,100
Btu/h 9,500 12,200 15,300 19,100 24,200
kW 3.2 4.0 5.0 6.3 8.0
Heating capacity kcal/h 2,700 3,400 4,300 5,400 6,800
Btu/h 10,900 13,600 17,000 21,500 27,300
Cooling 80 80 75 75 82Power input w
Heating 80 80 75 75 82
Cooling 0.4 0.4 0.4 0.4 0.5Rated current A
Heating 0.4 0.4 0.4 0.4 0.5
Airflow rate(H/M/L) m3/h 847/766/640 847/766/640 864/755/658 864/755/658 1,157/955/749
CFM 498/450/376 498/450/376 508/444/387 508/444/387 680/562/440Sound level dB(A) 42/38/35 42/38/35 42/38/35 42/38/35 45/42/39
Type R410ARefrigerant
Control method EXV
Net dim.(WxHxD) mm 840x230x840 840x230x840 840x230x840 840x230x840 840x230x840Body Grossdim.(WxHxO) 955X247X955 955X247X955 955X247X955 955X247X955 955X247X955
NeUgross kg 24/28 24/28 26/30 26/30 26/30Net dim.(WxHxD) 950x46x950 950x46x950 950x46x950 950x46x950 950x46x950mm
Panel Grossdim.(WxHxD) 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000NeUgross kg 6/8 6/8 6/8 6/8 6/8
L(flare) mm <1>6.35 <1>6.35 <1>6.35 <1>9.53 <1>9.53PipingG(flare) mm <1>12.7 <1>12.7 <1>12.7 <1>15.9 <1>15.9connectionsDrain piping mm 10<1>28.5 00<1>32 10<1>28.5 00<1>32 10<1>28.5 00<1>32 10<1>28.5 00<1>32 10<1>28.5 00<1>32
Drain pump pumphead mm 750 750 750 750 750
Standard Controller Wireless remotecontroller (R05/BG(T)E-A)
Model GAV-80-CK4-05-M5I
GAV-90-CK4-05-M5 I GAV-100-CK4-05-M5 I GAV-112-CK4-05-M5I
GAV-140-CK4-05-M5
Power supply 1-phase,220-240V,50Hz
kW 8.0 9.0 10.0 11.2 14.0Cooling capacity kcal/h 6,800 7,700 8,600 9,600 12,000
Btu/h 27,300 30,700 34,100 38,200 47,800
kW 9.0 10.0 11.0 12.5 15.0
Heating capacity kcal/h 7,700 8,600 9,400 10,700 12,900
Btu/h 30,700 34,100 37,500 42,600 51,200
Cooling 97 160 160 160 170Power input w
Heating 97 160 160 160 170
Cooling A 0.5 0.7 0.7 0.7 0.8Rated currentHeating 0.5 0.7 0.7 0.7 0.8
Airflow rate(H/M/L) m3/h 1,236/973/729 1,540/1,300/1,120 1,540/1,300/1,120 1,540/1,300/1,120 1,800/1,500/1,280
CFM 727/572/429 906/765/659 906/765/659 906/765/659 1059/883/753Sound level dB(A) 45/42/39 48/45/43 48/45/43 48/45/43 50/47/44
Type R410ARefrigerant
Control method EXV
Net dim.(WxHxD) mm 840x230x840 840x300x840 840x300x840 840x300x840 840x300x840
Body Grossdim.(WxHxD) 955X247X955 955X317X955 955X317X955 955X317X955 955X317X955NeUgross kg 26/30 32/37 32/37 32/37 32/37Net dim.(WxHxD) 950x46x950 950x46x950 950x46x950 950x46x950 950x46x950mm
Panel Grossdim.(WxHxD) 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000NeUgross kg 6/8 6/8 6/8 6/8 6/8
L(flara) mm <1>9.53 <1>9.53 <1>9.53 <1>9.53 <1>9.53PipingG(flare) mm <1>15.9 <1>15.9 <1>15.9 <1>15.9 <1>15.9connectionsDrain piping mm 10<1>28.5 00<1>32 10<1>28.5 00<1>32 10<1>28.5 00<1>32 10<1>28.5 00<1>32 10<1>28.5 00<1>32
Pump head mm 750 750 750 750 750Standard Controller Wireless remotecontroller (RM05/BG(T)E-A)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: Bm(horizontal)2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: ?°COB, 6°CWB,equivalent ref. Piping: Bm(horizontal)3. Sound level is measured at 1.4m below the unit.
GreenairINTERNATIONAL
Low Static Ducted Unit
[i!] Auto Restart
6 Auto Addressing Cleanable Panel
Fresh Air
D Follow Me It Anti-Cold Air Function
m Wired Controller R Super High Air Flow
"-........_ ~
Low sound level
Utilizes the cross blow fan,
provides a minimum noise
level of 21dB (A), an excellent
choice for hotels and other
sound-sensitive places.
V-shape evaporator-good for heat exchanging Convenient installationV-shape evaporator enhances heat exchanging efficiency
about 22%The EXV is fixed beside the indoor unit.
Compact design Options
Ceiling J CC::: ceiling
Uniform 21Ommin height, compact design for easyinstallation where space ceiling is limited,The whole body adopts fireproof plastic material,the minimum weight is 14kg.
A drain pump with 750mm pumphead is anoptional accessory.
GAV-M5
Model GAV-22-CC3-D5-M5 I GAV-28-CC3-D5-M5 I GAV-36-CC3-D5-M5 I GAV-45-CC3-D5-M5 I GAV-56-CC3-D5-M5 I GAV-71-CC3-D5-M5
PowerSupply 220-240V-1 Ph-50Hz
kW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling kcal/h 1,900 2,400 3,100 3,900 4,800 6,100
Btu/h 7,500 9,500 12,200 15,300 19,100 24,200Capacity
kW 2.6 3.2 4.0 5.0 6.3 8
Heating kcal/h 2,235 2,751 3,439 4,299 5,416 6,900
Btu/h 8,900 10,900 13,600 17,000 21,500 27,300
Input w 59 59 65 105 105 130Power (Cooling)
Rated Current A 0.31 0.31 0.36 0.36 0.36 0.5
Input w 59 59 65 105 105 130Power (Heating)
Rated Current A 0.31 0.31 0.36 0.36 0.36 0.5
m3/h 578/512/409 617/551/441 824/690/609 1060/973/811Indoorair flow (H/M/L)
CFM 340/301/241 363/324/260 485/406/358 624/571/477
ESP (external static pressure) Pa 10 10 10 10 10 10
Sound Pressure(Hi/Mid/Lo) dB(A) 35/27/24 35/27/24 38/32/28 39/32/29 39/32/29 41/33/30
Type R410ARefrigerant
ControlMethod EXV
Net dimension W><H><D mm 740x210x470 960x210x470 1180x210x470
Packing dimension W><H><D mm 91Ox230x51O 1130x230x51O 1350x230x51O
Net/GrossWeight kg 14/17.5 17.5/22 21/26.5
Liquid (Flare) mm <1>6.35 <1>6.35 <1>6-35 <1>9.53 <1>9-53 <1>9.53
Piping Connections Gas (Flare) mm <1>12.7 <1>12.7 <1>12.7 <1>15.9 <1>15.9 <1>15.9
Drain piping mm <1>25
Pumphead mm 750
Standard Controller Wireless remotecontroller (RM05/BG(T)E-A)
Notes:1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoortemp.:35°CDB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp : 20°CDB, outdoor temp.: ?°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured at 1.4m below the air outlet.
* External static pressure is based on high speed indoor air flow.
•
GreenairINTERNATIONAL
Medium Static Ducted Unit
Cleanable Panel
Auto Restart Fresh Air
Follow Me Anti-Cold AirFunction
Built-in DrainPump Wired Controller
Auto Addressing
~- __..--/ Connectable To Duct Super High Air Flow
Compact size External static pressureFour speed fan motor (Super high speed is
optional)
Change the wiring connection from 'SH' to
'Hi' to change the ESP.Ceiling_l
Only 210mm (22-71 models) or 270mm (80 to112 models) or 300mm (140 model) in height.
Convenient installationThe EXV is fixed inside of the indoor unit.Standard filter is housed in an aluminum frame, which is removable from the bottom in the downward direction.Suction chamber is included as standard equipment.Fresh air hole, air inlet/outlet flange are standard for easy duct connection.A rear air inlet is standard and an inlet at the bottom is optional. Both use the same connectable duct.
Air intake from back Air intake from below drain pump as standard
~ceiling
Flexible control and easy maintenance
Standard wired remote controller KJR-12B.The electrical control box can be removed 1m away from the unit for easy maintenance access. Customers needto request this service in advance as it is done at Green air factory.Standard functional ports are included such as Remote On/Off Dry contact switch and Alarm signal output(220V).
•
GAV-M5
Model GAV-22-CC2-D5-M5 I GAV-28-CC2-D5-M5 I GAV-36-CC2-D5-M5 I GAV-45-CC2-D5-M5 I GAV-56-CC2-D5-M5
Power Supply 220-240V-1Ph-50Hz
kW 2.2 2.8 3.6 4.5 5.6
Cooling kcal/h 1,891 2,407 3,095 3,869 4,815
Btu/h 7,500 9,500 12,200 15,300 19,100Capacity
kW 2.6 3.2 4 5 6.3
Heating kcal/h 2,235 2,751 3,439 4,299 5,416
Btu/h 8,900 10,900 13,600 17,000 21,500
Input w 59 57 61 92 92Power (Cooling)
Rated Current A 0.28 0.28 0.28 0.5 0.5
Input w 59 57 61 92 92Power (Heating)
Rated Current A 0.28 0.28 0.28 0.5 0.5
m'lh 570/530/410/320 570/530/410/320 570/530/410/320 9581850/667/583 9581850/667 /583Indoor air flow (H/M/L)
CFM 335/312/241 /188 335/312/241/188 335/312/241/188 563/500/392/343 563/500/392/343
ESP (external static pressure) Pa 10(10-30) 10(10-30) 10(10-30) 10(10-30) 10(10-30)
Sound Pressure (Hi/Mid/Lo) dB(A) 36/35/32 37/35/32 39/38/36 41/38.9/36 41/38.9/36
Type R410ARefrigerant
Control Method EXV
Net dimension WxHxD mm 700x21 Ox450 700x21 Ox450 700x210x450 920X210X570 920X210X570
Packing dimension WxHxD mm 870x285x525 870x285x525 870x285x525 1,135X290X655 1,135X290X655
Net/Gross Weight kg 17.5120 17.5/20 17.5/20 27/32 27/32
Liquid (Flare) mm <1>6.35 <1>6.35 <1>6.35 <1>6.35 <1>9.53
Piping Connections Gas (Flare) mm <1>12.7 <1>12.7 <1>12.7 <1>12.7 <1>16
Drain piping mm 10<1>2500<1>32 10<1>2500<1>32 10<1>2500<1>32 10<1>2500<1>32 10<1>2500<1>32
Pump head mm 750
Standard Controller - Wired controller KJR-128(6 meters connection wire)
Model GAV-71-CC2-D5-M5 I GAV-80-CC2-D5-M5 I GAV-90-CC2-D5-M5 I GAV-112-CC2-D5-M5I GAV-140-CC2-D5-M5
Power Supply 220-240V-1 Ph-50Hz
kW 7.1 8 9 11.2 14.0
Cooling kcal/h 6,105 6,879 7,739 9,630 12,037
btu/h 24,200 27,300 30,700 38,200 47,800Capacity
kW 8 9 10 12.5 15.5
Heating kcal/h 6,879 7,739 8,598 10,748 13,327
Btu/h 27,300 30,700 34,100 42,600 52,900
Input w 125 198 200 313 274Power (Cooling)
Rated Current A 0.7 1 1 1.8 1.55
Input w 125 198 200 313 274Power (Heating)
Rated Current A 0.7 1 1 1.8 1.55
m'lh 1,207/1,050/905/821 1,400/1,226/1,0181861 1,400/1,230/1,019/859 1,75Ql1,752/1,552/1,389 1,789.11,918/1,53911,250Indoor air flow (H/M/L)
CFM 710/618/532/483 917/795/687/608 917/795/687/608 1,214/1,059/9211824 1,258/1, 118/967/827
ESP (external static pressure) Pa 10(10-30) 20(10-50) 20(10-50) 40(10-80) 40(10-100)
Sound Pressure (Hi/Mid/Lo) dB(A) 42/40/35 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0
Type R410ARefrigerant
Control Method EXV
Net dimension WxHxD mm 1140X21 OX635 1,140X270X710 1,140X270X710 1,140X270X710 1,200X300X800
Packing dimension WxHxD mm 1,135X290X655 1,355X350X795 1,355X350X795 1,355X350X795 1,385X375X920
NeUGross Weight kg 31.8135.8 38146.5 40/48 40/48 49/58
Liquid (Flare) mm <1>9.53 <1>9.53 <1>9.53 <1>9.53 <1>9.53
Piping Connections Gas (Flare) mm <1>15.9 <1>15.9 <1>15.9 <1>15.9 <1>15.9
Drain piping mm 10<1>2500<1>32 10<1>2500<1>32 10<1>2500<1>32 10<1>2500<1>32 10<1>2500<1>32
Pump head mm 750
Standard Controller - Wired controller KJR-128(6 meters connection wire)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: am (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: am (horizontal)
3. Sound level is measured at 1.4m below the air out-let.
* External static pressure is based on high speed indoor air flow.
* Specifications are subject to change without prior notice for product improvement.
GreenairINTERNATIONAL
High Static Ducted Unit
Auto Restart Fresh Air
Auto Addressing Cleanable Panel
Follow Me Anti-Cold Air Function
Wired Controller Connectable To Duct
Flexible duct designFour speed fan motor (super high speed as an option for models 70-160)External static pressure can be up to 196Pa (models 71to160) or 250Pa (models 200 to 560).
the longest distanceof air supply is 14m
Fresh air in take
420mm 450mm• I INDOORUNAirsupply Theheightofair Airreturn
supply is 6.sm INDOOR UNIT
The maximum distance for air supply is about 14m at height of 6.5m.With a 420mm (models 71to160) thick body, the minimum distance required above the ceiling is 450mm.
Greater flexibility with the four-speed fanExchange the wiring connections for 'MH' and 'Me' (models 71 to 160).
Convenient installationThe EXV is fixed inside the indoor unit (models 70-160), requires no extra connection.Standard filter is housed in an aluminum frame, which is removable from the bottom in the downward direction.Flange for air in/outlet duct connection is standard.
Flexible control and convenient for maintenanceWired remote controller KJR-108/KJR-128 is standard, and wireless remote controller ROSis optionalThe display board is connected to the E-box in factory, easier troubleshooting by LED display.Easy access filters both at the rear & bottomStandard functional port such as remote on/off dry contact.
Option Double-skin drainage pan
~~~-~mm
~ceilingDrainpumpwith750mmpumpheadis optional(models71to 160)
Double-skin drainage pan providesdouble protection forceilings (models 71 to 160 and models 400 to 560)
GAV-M5
Model GAV-71-CC1-D5-M5 I GAV-80-CC1-D5-M5 I GAV-90-CC1-D5-M5 I GAV-112-CC1-D5-M5I GAV-140-CC1-D5-M5I GAV-160-CC1-D5-M5
Power Supply 220-240V-1 Ph-50Hz
kW 7.1 8 9 11_2 14 16
Cooling kcal/h 6,105 6,879 7,739 9,630 12,037 13,757
Btu/h 24,200 27,300 30,700 38,200 47,800 54,600Capacity
kW 8 9 10 12_5 16 18
Heating kcal/h 6,879 7,739 8,598 10,748 13,757 15,477
Btu/h 27,300 30,700 34,100 42,600 54,600 61,400
Input w 263 263 423 524 627 832Power (Cooling)
Rated Current A 1.1 1.1 1_8 2.3 2.7 3.6
Input w 263 263 423 524 627 832Power (Heating)
Rated Current A 1.1 1.1 1_8 2.3 2.7 3.6
m3/h 1,510/1,399/1,236 1,500/1,396/1,221 1,936/1,721/1,511 2, 117/1,950/1,644 2,988/2,670/2,229 3,890/3,200/2,700Indoor air flow (H/M/L} CFM 889/823/727 88318221719 1,139/748/889 1,246/1, 1471968 1,758/1,572/1312 2,290/1,883/1,589
ESP (external static pressure) Pa 40(30-196) 40(30-196) 40(30-196) 50(30-196) 50(30-196) 50(30-196)
Sound Pressure (Hi/Mid/Lo) dB(A) 48146144 48/46/44.5 52/49/47 52/49/47 53150/48 54/52/50
Type R410ARefrigerant
EXVControl Method
Net dimension WxHxD mm 952•420•690 952•420•690 952•420•690 952•420•690 1,200•400•600 1,200•400•600
Packing dimension WxHxD mm 1,102•450•768 1,102•450•768 1,102•450•768 1,102•450•768 1,430•450•768 1,430•450•768
Net/Gross Weight kg 45/50 45/50 46.5/52.4 50.6/56 68/70 70/77_5
Liquid (Flare) mm <1>9.52 <1>9.53 <1>9.53 <1>9-53 <1>9.53 <1>9.53
Piping Connections Gas (Flare) mm <1>15.9 <1>15.9 <1>15.9 <1>15.9 <1>15.9 <1>15.9
Drain piping mm ID<l>250D<l>32 ID<l>250D<l>32 ID<l>25OD<l>32 ID<l>250D<l>32 ID<l>25OD<l>32 ID<l>250D<l>32
Pump head mm 750
Standard Controller Wired controller KJR-10B/DP(T}-E (6mwireis standard) Wired controller KJR-12B/DP(T)-E (6mwire is standard)
Model GAV-200-CC1-D5-M5 IGAV-250-CC1-D5-M5 I GAV-280-CC1-D5-M5I GAV-400-CC1-D5-M5 I GAV-450-CC1-D5-M5 I GAV-560-CC1-D5-M5
Power Supply 220-240V-1Ph-50Hz
kW 20 25 28 40 45 56
Cooling kcal/h 17,197 21,496 24,075 34,394 38,693 48,152
Btu/h 68,200 85,300 95,500 136,500 153,500 191,100capacity
kW 22.5 26 31.5 45 50 63
Heating kcal/h 19,346 22,355 27,084 38,693 42,993 54,171
Btu/h 76,800 88,700 107,500 153,500 170,600 214,960
Input w 1516 1516 1516 2700 2700 3400Power (Cooling)
Rated Current A 6.6 6.6 6.6 12.5 12.5 15.5
Input w 1516 1516 1516 2700 2700 3400Power (Heating)
Rated Current A 6.6 6.6 6.6 12.5 12.5 15.5
m3/h 4,268/3, 780/3,200 4,280/3,820/3,200 4,400/3, 708/3,200 7468/6047/4989 746816047/4989 9506/7897/6550Indoor air flow (H/M/L}
CFM 2,512/2,225/1,883 2,519/2,248/1,833 2,59012,182/1,883 4396/3559/2936 4396/3559/2936 5595/4648/3855
ESP (external static pressure) Pa 140(50-250) 140(50-250) 160(50-250) 196(50-250) 196(50-250) 196(50-250)
Sound Pressure (Hi/Mid/Lo) dB(A) 59/55/52 59/55/52 59/55/52 61/59/56 61/59/56 63160/57
Type R410ARefrigerant
EXVControl Method
Net dimension WxHxD mm 1356•470•763 1356•470•763 1356•4 70•763 1970*668*858.5 1970*668*858.5 1970*668*858.5
Packing dimension WxHxD mm 1,509•522•964 1,509•522•964 1,509•522•964 2095*800*964 2095*800*964 2095*800*964
Net/Gross Weight kg 115/129 115/129 115/129 2321245 232/245 2321245
Liquid (Flare) mm <1>9.53•2 <1>9.53•2 <1>9.53•2 <1>12.7*2 <1>12.7*2 <1>12.7*2
Piping Connections Gas (Flare) mm <1>15.9•2 <1>15.9•2 <1>15.9•2 <1>22.2x2 <1>22.2x2 <1>22.2x2
Drain piping mm ID<l>250D<l>32 ID<l>250D<l>32 ID<l>25OD<l>32 ID<l>250D<l>32 ID<l>25OD<l>32 ID<l>25OD<l>32
Pump head mm 750
Standard Controller Wired controller KJR-128/DP(T}-E (6m wire is standard)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27"CDB, 19"CWB, and outdoor temp.:35"CDB, equivalent ref. piping: am (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20"CDB, outdoor temp.: ?"COB, 6"CWB, and equivalent ref. Piping: am (horizontal)3. Sound level is measured at 1.4m below the air out-let.
* External static pressure is based on high speed indoor air flow.
* Specifications are subject t? i:h?_r-ge without prior notice for product improvement.
GreenairINTERNATIONAL
Ceiling & floor
Auto Restart FreshAir
Auto Addressing CleanablePanel
FollowMe Anti.ColdAir Function
LEDDlsplay~- --~ ~
Panel with LED displayThe front panel and display panel have different colors to choose from, white and brown for big panel, blue andbrown for small panel. Other colors are available if required.
Convenient installation• The unit even can be easily installed at the
corner of a narrow ceilings.• It is especially useful when central installation is
impossible due to features such as lights.
The unit can be installed either horizontally on theceiling or vertically against the wall.
Quiet and comfortable environment
Drop ceiling
Air Outlet
• The slim and sleek design starting at just 30kg enables quick, easy and neat installation.• Low noise operations; minimum 36 dB(A)
Auto swing and wide angle air flow
1.Auto horizontal and auto vertical swing functions for more even andcomfortable airflow.
2.Three air flow speeds: low, medium and high; double air guides.3.Adopt electronic expansion valve, ensure precise flow control, lowermodulation noise when EXV operating.
4.Smoother airflow and less turbulence due to the multi-blade fan andthe air guide design.
GAV-M5
Model GAV-36-CF-D5-M5 I GAV-45-CF-D5-M5 I GAV-56-CF-D5-M5 I GAV-71-CF-D5-M5 I GAV-80-CF-D5-M5
Power supply 1-phase, 220-240V, 50Hz
kW 3.6 4.5 5.6 7.1 8
Cooling capacity kcal/h 3,100 3,800 4,800 6,100 6,800
Btu/h 12,200 15,300 19,100 24,200 27,300
kW 4 5 6.3 8 9
Heating capacity kcal/h 3,400 4300 5,400 6,800 7,700
Btu/h 13,600 17,000 21,500 27,300 30,700
Cooling 49 120 122 125 130Power input w
Heating 49 120 122 125 130
Cooling 0.55 0.55 0.55 0.57 0.6Rated current A
Heating 0.55 0.55 0.55 0.57 0.6
m3/h 650/570/500 800/600/500 800/600/500 800/600/500 1,200/900/700Airflow rate(H/M/L)
CFM 383/335/294 471/353/294 471/353/294 471/353/294 706/530/412
Sound level dB(A) 40/38/36 43/41/38 43/41/38 43/41/38 45/43/40
Type R410ARefrigerant
EXVControl method
Net dimension(WxHxD) mm 990x660x206 990x660x206 990x660x206 990x660x206 1,280x660x206
Packing dimension(WxHxD) mm 1,089x744x296 1,089x744x296 1,089x744x296 1,089x744x296 1,379x744x296
Net weight kg 26 28 28 28 34.5
Gross weight kg 32 34 34 34 41L(flare) mm <1>6.35 <1>6.35 <1>9.53 <1>9.53 <1>9.53
PipingG(flare) mm <1>12.7 <1>12.7 <1>15.9 <1>15.9 <1>15.9
connectionsDrain piping mm OD<l>16 OD<l>16 OD<l>16 OD<l>16 OD<l>16
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)
Model GAV-90-CF-D5-M5I
GAV-112-CF-D5-M5 I GAV-140-CF-D5-M5 I GAV-160-CF-D5-M5
Power supply 1-phase, 220-240V, 50Hz
kW 9 11.2 14 16
Cooling capacity kcal/h 7,700 9,600 12,000 13,757
Btu/h 30,700 38,200 47,800 54,600
kW 10 12.5 15.5 18
Heating capacity kcal/h 8,600 11,000 13,000 15,477
Btu/h 34,100 42,600 52,900 61,400
Coolinq 130 182 182 300Power input w
Heating 130 182 182 300
Cooling 0.6 0.83 0.83 1.41Rated current A
Heating 0.6 0.83 0.83 1.41
m3/h 1,200/900/700 1,980/1,860/1,730 1,980/1,860/1, 730 1,980/1,860/1, 730Airflow rate(H/M/L)
706/530/412 1,165/1,095/1,018 1,165/1,095/1,018 1,165/1,095/1,018CFM
Sound level dB(A\ 45/43/40 47/45/42 47/45/42 47/45/42
Type R410ARefrigerant EXVControl method
Net dimension(WxHxD) mm 1,280x660x206 1,670x680x244 1,670x680x244 1,670x680x285
Packing dimension(WxHxD) mm 1,379x744x296 1,764x760x329 1,764x760x329 1,775x760x372
Net weight kg 34.5 54 54 57.5
Gross weight kg 41 59 59 63.5
L(flare) mm <1>9.53 <1>9.53 <1>9.53 <1>9.53Piping
G(flare) <1>15.9 <1>15.9 <1>15.9 <1>15.9mmconnections
Drain piping mm OD<l>16 OD<l>16 OD<l>16 OD<l>16
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)
Notes:
1. Nominal cooling capacities are based on the following conditions: re'b.Jrnair temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: Bm (horizontal)2. Nominal heating capacities are based on the following conditions: return air temp.: 20"CDB, outdoor temp.: 7"CDB, 6°CWB, and equivalent ref. Piping: Sm (horizontal)3. Floor standing :Sound level is measured 1m from air-ouUet in horizontal distance, 1m above the floor in vertical distance.
Ceiling mounted: Sound level is measured 1m from air-outlet in horizontal distance, 1m from air-outlet in vertical distance.* Specifications are subject to change without prior notice for product improvement.
GreenairINTERNATIONAL
Wall mounted
- -LED Display
Auto Restart
Auto Addressing
Cleanable Panel
Anti-Cold Air Function
Follow Me
'-...... /- --Panel with LED displayThe front panel and display panel have different colors to choose from,white and brown for big panel, blueand brown for small panel.
Convenient installation• Multi-refrigerant outlet pipe method: left\right\rear, more
flexible for installation.• The EXV is built-in the indoor unit, compact size, Longer
the connection pipe;gas pipe: 468mm; liquid pipe:550mm, more flexible for installation
• Adopts new type fixing plate, is easy to install and stable.
Auto swing louverSwing Louver
The Auto that the. ensures
:~;~~~~:tion corresponds to••ode selected. CDthe m 't-
1 @I\ @_..... Step '\ ©
.••• Swing '4.••...•....
Easy maintenanceThe front panel can be removed for easymaintenance access.
Optimal comfort through better flow control and quiet operationsThe mechanical expansion valve offers 2,000-stageelement positions to ensure precise flow control and lessmodulation noise when the EXV is operating for a quiet andcomfortable environment. Three air flow speeds: low,medium and high; double air guides. Smoother airflow andless turbulence is ensured by the multi-blade fan and theair guide design.
•
GAV-M5
Model GAV-22-WM-D5-M5 I GAV-28-WM-D5-M5 I GAV-36-WM-D5-M5 I GAV-45-WM-D5-M5 I GAV-56-WM-D5-M5
Power supply 1-phase, 220-240V, 50Hz
kW 2.2 2.8 3.6 4.5 5.6Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Btu/h 7,500 9,500 12,300 15,400 19,100
kW 2.4 3.2 4 5 6.3Heating capacity kcal/h 2,200 2,700 3,400 4,300 5,400
Btu/h 8,900 10,900 13,600 17,000 21,500
Cooling 28 28 28 45 45Power input w
Heating 28 28 28 45 45
Cooling 0.14 0.14 0.14 0.2 0.2Rated current A
Heating 0.14 0.14 0.14 0.2 0.2
m3/h 525/480/430 525/480/430 525/480/430 860/755/630 925/860/755Airflow rate(H/M/L)
CFM 309/283/253 309/283/253 309/283/253 506/444/371 544/506/444
Sound level dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34
Type R410ARefrigerant
EXVControl method
Net dlmenslonfvvxl-l=D] mm 915x290x210 915x290x210 915x290x210 1,070x315x210 1,070x315x210
Packing dimension(WxHxD) mm 1,020x385x300 1,020x385x300 1,020x385x300 1,165x395x285 1,165x395x285
Netweight kg 12 12 12 16 16
Gross weight kg 16 16 16 19 19
L(flare) mm <1>6.35 <1>6.35 <1>6.35 <1>6.35 <1>9.53Piping
G(flare) <1>12.7 <1>12.7 <1>12.7 <1>12.7 <1>15.9mmconnections
Drain piping mm 00<1>16.5 00<1>16.5 00<1>16.5 00<1>16.5 00<1>16.5
Standard Controller Wireless remote controller (RM05/BG(T)E-A)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: Bm {horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp: ?°COB, 6°CWB, and equivalent ref. Piping: Bm {horizontal)
3. Sound level is measured 1m below the air outlet horizontally and vertically.
* Specifications are subject to change without prior notice for product improvement.
Model GAV-71-WM-D5-M5I
GAV-80-WM-D5-M5I
GAV-90-WM-D5-M5
Power supply 1-phase, 220-240V, 50Hz
kW 7.1 8 9Cooling capacity kcal/h 6,100 6,800 7,700
Btu/h 24,200 27,300 30,700
kW 8 9 10Heating capacity kcal/h 6,800 7,700 8,600
Btu/h 27,300 30,700 34,100
Cooling 79 95 95Power input w
Heating 79 95 95
Cooling 0.33 0.39 0.39Rated current A
Heating 0.33 0.39 0.39
m'/h 1,190/880/680 1,320/840/640 1,320/840/640Airflow rate(H/M/L)
CFM 700/518/400 776/494/376 776/494/376
Sound level dB(A) 45/42139 47/43/41 47/43/41
Type R410ARefrigerant
EXVControl method
Net dimension(WxHxD) mm 1,250x325x230 1,250x325x230 1,250x325x230
Packing dimension(WxHxD) mm 1,345x335x430 1,345x335x430 1,345x335x430
Net weight kg 19.9 19.9 19.9
Gross weight kg 25 25 25
L(flare) mm <1>9.53 <1>9.53 <1>9.53Piping
G(flare) <1>15.9 <1>15.9mm <1>15.9connections
Drain piping mm 00<1>16.5 00<1>16.5 00<1>16.5
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: Sm (horizontal)2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: Sm (horizontal)
3. Sound level is measured 1m below the air outlet horizontally and vertically.* Specifications are subject to change without prior notice for product improvement.
GreenairINTERNATIONAL
Floor standing
- LED Dlsplay
Auto Restart Cleanable Panel
Auto Addressing Anti-Cold Air Function
Follow Me
'~ ,,,..,/- --
Easy installationFloor standing types can be hung on the wall or installed on the floor. The floor type unit can make cleaningand maintenance much easier. Running the piping from the rear allows the unit to be hung on walls. Cleaningunder the unit, where dust tends to accumulate, is considerably easier.
Easy maintenanceFilter is provided as a standard accessory. It can be removed and cleaned easily thanks to Green airsophisticated design and the product's removable blades.
The streamlined appearance harmonizes the unit with a given room's interior decor. All metal parts are madeof commercial grade galvanized steel for maximum protection against corrosion.
Optional panel styles
Concealed floor standing type The body is concealed in the skirting board to improve aesthetics.The body is just 212mm deep, and can be installed at the room'sperimeter. Special installation methods eliminate noise in the roomarea.
F3seriesconcealedtype Air intake from front(F4 series) Air intake from below(F5 series)
GAV-M5
Model GAV-22-FS-D5-M5 IGAV-28-FS-D5-M5 IGAV-36-FS-D5-M51 GAV-45-FS-D5-M5 IGAV-56-FS-D5-M5 IGAV-71-FS-D5-M5 IGAV-80-FS-D5-M5
Power supply 1-phase, 220-240V, 50Hz
kW 2.2 2.8 3.6 4.5 5.6 7.1 8
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800 6,100 6,900
Btu/h 7,500 9,500 12,200 15,300 19,100 242,00 27,300
kW 2.4 3.2 4 5 6.3 8 9
Heating capacity kcal/h 2,100 2,700 3,400 4,300 5,400 6,900 7,700
Btu/h 8,200 10,900 13,600 17,000 21,500 27,300 30,700
Cooling 40 46 40 49 88 130 130Power input w
Heating 40 46 35 49 88 130 130
Cooling 0.19 0.2 0.19 0.22 0.38 0.57 0.57Rated current A
Heating 0.19 0.2 0.15 0.22 0.38 0.57 0.57
m3/h 530/456/400 569/485/421 624/522/375 660/542/440 1,150/970/830 1,380/1, 100/870 1,332/1,212/1,023Airflow rate(H/M/L)
CFM 312/268/235 335/285/248 367/307/221 388/319/259 677/571/489 812/647/512 784/713/602
F3B 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33Soundlevel(Hi/Mid/Lo) F4 dB (A) 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33
F5 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33
Type R410ARefrigerant
Control method EXV
F3B 840x212x545 840x212x545 1,036x212x545 1,036x212x545 1,336x212x545 1,336x212x545 1,336x212x545Net dimension F4 mm 1,000x220x625 1,000x220x625 1,200x220x625 1,200x220x625 1,500x220x625 1,500x220x625 1,500x220x625(WxHxD)
F5 1,000x220x625 1,000x220x625 1,200x220x625 1,200x220x625 1,500x220x625 1,500x220x625 1,500x220x625
F3B 925x305x639 925x305x639 1,125x305x639 1,125x305x639 1,425x305x639 1,425x305x639 1,425x305x639Packingdimension F4 mm 1,089x312x722 1,089x312x722 1,289x312x722 1,289x312x722 1,589x312x722 1,589x312x722 1,589x312x722(WxHxD)
F5 1,182x312x722 1,182x312x722 1,382x312x722 1,382x312x722 1,682x312x722 1,682x312x722 1,682x312x722
F3B 26/29.5 26/29.5 29.5/34 29.5/34 36/40 36/40 36/40Net/Grossweight F4 kg 30/35 30/35 37/43 37/43 44/50 44/50 44/50
F5 30/38 30/38 37/46 37/46 44/53 44/53 44/53
L(flare) mm <1>6.35 <1>6.35 <1>6.35 <1>6.35 <1>9.53 <1>9.53 <1>9.53Piping
G(flare) mm <1>12.7 <1>12.7 <1>12.7 <1>12.7 <1>15,9 <1>15.9 <1>15,9connectionsDrain piping mm 00<1>16 00<1>16 00<1>16 00<1>16 00<1>16 00<1>16 00<1>16
Standard Controller Wireless remote controller (RM05/BG(T)E-A)
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp .. 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: Sm (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp .. 20°CDB, outdoor temp .. ?°COB, 6°CWB, and equivalent ref. Piping: Sm (horizontal)
3. Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance.* Specifications are subject to change without prior notice for product improvement.
•
GreenairINTERNATIONAL
Fresh Air Processing unit
"-.. --- /- -~Healthy and comfortable
Fresh air is important, provides a healthy and comfortable living environment.
100% Fresh air processing unitthe longest distanceof air supply is 14m Both fresh air filtration and heating/cooling can be
achieved in a single system.Indoor units and fresh air processing unit can beconnected to the same refrigerant system, increaseddesign flexibility and greatly reduced total system costs.
Fresh air in take
INDOOR UNI
Air supply Air returnThe height of airsupply is 6.5m
High external static pressureExternalstatic pressure can be up to 220Pa(models 125to 140)and 260Pa(models 200 to 280) for more flexible ductapplications. The maximum distance of air supply is about 14mand the maximum height of air supply is about 6.5m.
Innovative air supply technology for excellent room temperature control
Layout Example:
Outdoor Units
Indoor UnitIndoor Unit
Outdoor Air processing unit
Air-conditioning Fresh air supply
•
GAV-M5
Model GAV-125-FA-D5-M5 I GAV-140-FA-D5-M5 I GAV-200-FA-D5-M5 I GAV-250-FA-D5-M5 I GAV-280-FA-D5-M5
Power Supply 1-phase, 220-240V, 50Hz
kW 12.5 14 20 25 28
Cooling kcal/h 10,766 12,057 17,225 21,531 24,115
Btu/h 42,600 47,800 68,200 85,300 95,500Capacity
kW 18 20 2210.5 12Heating kcal/h 9,043 10,335 15,502 17,225 18,947
Btu/h 35,800 41,000 61,400 68,200 75,000
Input w 461 461 1063 1,063 1063Power (Cooling)
Rated Current A 2.3 2.3 5.3 5.3 5.3
Input w 461 461 1063 1,063 1,063Power (Heating)
Rated Current A 2.3 2.3 5.3 5.3 5.3
m3/h 1,700/1,350/1,050 1,700/1,350/1,050 3,150/2,650/2,300 3,300/2,850/2,500 3,300/2,850/2,500Air flow (H/M/L)CFM 1,000/795/618 1,000/795/618 1,854/1,560/1,354 1,942/1,677/1,471 1,942/1,677/1,471
ESP (external static pressure) Pa 50(30-220) 50(30-220) 140(50-260) 140(50-260) 140(50-260)
Sound Pressure (Hi/Mid/Lo) dB(A) 54/52/50 54/52/50 54/53/51 55/54/52 55/54/52
Type R410ARefrigerant
EXVControl Method
Net dimension WxHxD mm 1,200x400x600 1,200x400x600 1,425x500x928 1,425x500x928 1,425x500x928
Packing dimension WxH><D mm 1,436x450x768 1,436x450x768 1,509x550x990 1,509x550x990 1,509x550x990
Net/Gross Weight kg 69.5/76 69.5/76 115/125 115/125 115/125
Liquid (Flare) mm <1>9.53 <1>9.53 <1>9.53 <1>9.53 <1>9.53Piping Connections Gas (Flare) mm <1>15.9 <1>15.9 <1>15.9 <1>15.9 <1>15.9
Drain piping mm OD<l>25 OD<l>25 OD<l>32 OD<l>32 OD<l>32
Pump head mm 750 - - -
Standard Controller - Wired controller KJR-128/DP(T)-E (Sm wire is standard)
Notes:
1 . Nominal cooling capacities are based on the following conditions: outdoor air temp.: 33°C DB, 24°C WB, equivalent ref. piping: Sm (horizontal)2. Nominal heating capacities are based on the following conditions: outdoor air temp.: 0°CDB, -1°CWB, equivalent ref. Piping: Sm (horizontal)
3. Sound level is measured 1.4mfrom the air out-let.external static pressure are based on high speed indoor air flow.
Specifications are subject to change without prior notice for product improvement.Connection Conditions:
The following restrictions must be observed in order to maintain the indoor units connected to the same system.
When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units.
When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units.Outdoor-air processing units can be used without indoor units.
GAV-M5
Heat Recovery Ventllator
~in
GreenairINTERNATIONAL
HRVHeat recovery ventilator
Model Names
SA(Supply airto room)
Compact design, flexible installation and easy maintenance
Larger air supply rateenhanced heat exchange efficiencyenhanced energy saving property
HRV-200HRV-300HRV-400
HRV-500HRV-800HRV-1000
The heat recovery ventilator (HRV} can reclaimheat energy lost through ventilation and reducethe room temperature fluctuation caused byventilation process. By utilizing the mostadvancedtechnologyand techniqueGreenair HRVhas extremely good performance.The heatexchanged core is made of special paperprocessedwith chemical treatment, which couldrealize better temperature and humidity control ofthe room environment. Temperature exchangeefficiency is above 65% and enthalpy exchangeefficiency between 50-65%.
HRV-1500 HRV-2000
RA(Returm airfrom room)
Low noiseOA(Fresh air fromoutdoors)
Sound proof material is used to guarantee quiet operation.
With a min. height of only 264mm and 23kg weight, theunit provides best convenience and possibility forinstallation in limited spaces.
GAV-M5
Multi-modes for different situationsHeat exchange modeWhen air flow formed by the fans goes through the heat Heatexchangemodeexchangedcore in crossway, due to temperaturedifferencebetweentwo channelsof the core, thermal transmissionhappens EA
naturally.In summerdays, high temperatureoutdoor air gets cooled byindoorexhaust air; in winter, low temperatureoutdoor air gets OA
heatedby indoorexhaust air. So the energy contained in exhaustair can be reclaimedand energy efficiencygets improved.
RA
SA
Bypass modeRAIn mild climate areas or seasons,when temperatureand humidity EA
level differencebetween indoorand outdoor is small, the unitworks as conventionalventilation fan. Both supply fan andexhaust fan works at the same speed (Hi/mid/low/auto). OA SA
Air supply mode
Exhaust air mode Auto mode
It is one kind of bypassmodewith air supply fan speed higher than exhaust fan speed. It canbe used in mild climate areawhere large amount fresh air is needed.
It is also one kind of bypassmodewith exhaust fan speedhigher than air supply fan speed. It can be used in mildclimate areawhere large amountexhaust air needsto beexpelled.
The controllerchooses heat exchangemodeorbypass mode according to the temperaturedifference between outdoor and indoortemperature.Both the two fans work at low speed.
Flexible controlInterlockingcontrolwith other indoor units by controller is possible.
Centralized control '
GreenairINTERNATIONAL
SpecificationsModel
Power Supply
Temp. Exchange Efficiency(%) [50Hz]
Enthalpy
Exchange
Efficiency (%)
[50Hz]
Sound Level
For Cooling
For Heating
Heat
Exchange
Mode
Bypass
Mode
Dimensions(WxDxH)
Machine Weight
Casing
Heat Exchange System
Heat Exchange Element Material
I Fan
High
Medium
Low
High
Medium
Low
High
Medium
Low
High
Medium
Low
GAV-HRV-200-M5 GAV-HRV-300-M5
V/ph/Hz
65
65
70
50
50
55
55
55
60
30
29
23
31
30
25
944x722x270
26
%65
65
70
50
50
55
55
55
60
27
26
20
28
27
22
866x655x264
23
--1---% 1---
1---
1---
dB(A) 1---
-+-mm
kg
Type
Airflow Rate
[50Hz]
ESP (Pa) [50Hz]
Duct diameter
Operation ambient condition
Model
Power Supply
Temp. Exchange Efficiency (%) [50Hz]
Enthalpy
Exchange
Efficiency (%)
[50Hz]
Sound Level
For Cooling
For Heating
Heat
Exchange
Mode
Bypass
Mode
Dimensions(WxDxH)
Machine Weight
Casing
Heat Exchange System
Heat Exchange Element Material
Fan
Airflow Rate
[50Hz]
ESP (Pa) [50Hz]
Motor Output
High
Medium
Low
High
Medium
Low
Motor Output
High
Medium
Low
High
Medium
Low
High
Medium
Low
High
Medium
Low
-+---
GAV-HRV-400-M5 GAV-HRV-500-M5
220-240/1/50
65
65
70
50
50
55
60
60
65
32
31
25
33
32
27
944x927x270
31
65
65
70
50
50
55
60
60
65
35
34
28
36
35
30
10,38X1,026X270
41
-+- --+--
Galvanized steel plate
Air to air cross flow total heat (Sensible heat + latent heat) exchange
Speciajly processed nonflammable paper
Centrifugal fan
300
2. Sound level is measured at 1.4m below the center of the body in an anechoic chamber ..3. Airflow rate can transmit between low mode and high mode4. Temperature Exchange Efficiency is the mean value between cooling and heating5. Efficiency is measured under the following conditions:• Cooling Condition: Air Exhaust Temp. 27°C DB,19.5'CWB., Fresh Air Temp. 35'C DB,28'CWB• Heating Condition: Air Exhaust Temp. 21'C DB,13'CWB., Fresh Air Temp. 5'C DB,2'CWB
+ 200
200
150
75
58
35
20
144
'-7'C-43'C (DB), 80%RH or less
300
225
75
60
40
40
144
m3/h +-+--+
Pa -+--
400 500
500
375
80
68
45
120
194
w<l>/mm
GAV-HRV-800-M5 GAV-HRV-1000-M5
V/ph/Hz 220-240/1/50
400
300
80
65
43
80
144
%65
65
70
50
50
55
60
60
65
39
38
32
40
39
34
1,286x 1,006x388-+-
62
65
65
70
50
50
55
60
60
65
40
39
33
41
40
35
1,286x1 ,256x388
79
1---
GAV-HRV-1500-M5 GAV-HRV-2000-M5
1---
1---
380/3/50
%1---
1---
65 65
1---
1---
dB(A)1---
-+- mm
kg
50 50
60 60
51 53
52 54
I
1,600x 1,270x540
163
1,650x1 ,470x540
182-- Galvanized steel plate
Air to air cross flow total heat (Sensible heat + latent heat) exchange
Specially processed nonflammable paper
+-+--
Centrifugal fan
1,000
1,000
Type
High
Medium
Low
High
Medium
Low
800
800
600
100
82
54
360
242
m3/h +
1,500
I
450
346x326
750
100
85
58
360
2,000
I
160
I170
+--+--
Pa+
w<l>/mm
450
242 346x326
'-7'C-43'C (DB), 80%RH or lessDuct diameter
Operation ambient conditionNote:1. For the units model of HRV (200-1000), there are 3-6peed adjustable air volume (Hi, Med, Low), but for the units model of HRV (1500-2000), there are only t-speed which cannot be adjusted.
•
GreenairINTERNATIONAL
Control SystemsNetwork Control
Router
/Remote Service Centre
Greenaitli1!lllD
User's MonitoringSystem
Connectable tovarious sized Gateway
,;::·:.·,,·:·
IMGSoftware M-INTERFACEGateway
;~,--:-..,."f";,--.--'MD-LonGW64LonworksBMS
MD-CCM08
BACnetBMS .....:._
Web monitoringsystem
ModbusBMS Modbusgateway
•
Centralized Control
Indoor Centralized Controller(Touch-style Key)
-1 EEi0
CCM30
Weekly ScheduleCentralized Controller
-MD-CCM09
Indoor CentralizedController
MD-CCM03
Outdoor CentralizedController
MD-CCM02
Note:Thewires in the diagramshow the signal flows only,while not representthe actual connectingways.
GAV-M5
Individual control
Wired controllerKJR-1OB [ •1KJR-128KJR-90AKJR-298KJR-86CKJR-120A
*..:.;; •t <!><lllllrl"rl G ~""
Remote controllerRM02RM05R05R06R51R71
II
Accessories
Card-key Interface11111
I·~. ~·I MD-NIMOS L~
MD-NIM05
I
~Card-key
Remote Alarm Controller
''
- "•••KJR-328
Outdoor units
•
GreenairINTERNATIONAL
Com arison of ControllersItem Remote Wired Controller Centralized
Model name RM05/RM02 R51/R71 R05/R06 KJR-108 KJR-90A KJR-298 CCM30 MD-CCMCB KJR-908/KJR-120A /KJR-86C /KJR-128 /MD-CCMCB /KJRF-180A
MAX. controllable IOU removable 1 1 1 64 64/16 16
On/Off • ~ • ""u c ~ ~ ~
Operation mode setting • • • • • c c c •Fan speed setting 0 • • • 0 c c c -Room temp. setting • • • • • c c;: c -Vertical swing u - ti - - - - - -Horizontal swing t' t• ti ti t,/- t) t: t,/- -
A/C control Air direction t/- -/ • - - - - - -
functionEconomic mode • • I- • - -I - - -Group setting - - - - - - c c •Key lock • /- • • - c c ~ -
Mode lock - - - - - - • I- -Remote signal receiving - - - - - I- - - -
26'C shortcut setting -/ - - - -/ /- - - -
8acklighl ~ - • -I -I e • c •Current lime ti- - • .., /- - - c -
Display RC prohibition - - - - - - t: t: -Address - - - - - - c I!"! -
Error code - - - -/ - - • /- -Period - - - - - - - Week -
On/Off per day - - - - - - - 4 -Timer
On/Off per week - - - - - - - 28 -On/Off timer 0 • • • I- c c;: ~ -FOLLOW ME -I - - - - c - - -Emergent stop - - - - - - c;: /- -Emergent start - - - - - - • I- -Address setting • - - - - e - - -
Control c8MS access - - - - - - - -Control via internet - - - - - - ~ - -Air filter cleaning reminding - - - -/t - t/- U/- - -
1O'C heat function - - - -/ - - - - -
O : Available controller functions
- : Not available controller functions
ID
GAV-M5
Wireless Remote Controller
I I- ""'' F • ~
(' f. -- . ('"- (":
g (iil
~r6rR71
-:;i~
-· -'-'"R51
~~
ROG
~"='
ROSRM05RM02
Functions
Portable deviceThe wireless remote controller is a portable controldevice that enables users to control the A/Canywhere within a distance of 11m.
Background light
Simplified user interfaceUsers can synchronize the air conditioners' parameters with the display panel on the wireless remotecontroller to precisely control a room's environment.
~( ON/OFF )Transmittingdispla
(Running mod0 C4:
(Economicoperatio~l8·>----~ ~~~-@( Fan speed)
The background light allows users to operate thedevice in a dark room. The device lights up when abutton is pressed, and turns off when a givenoperation is completed.
Built-in timer
HEATMode COOLMode
• IIDIaEconomic Addressingoperation setting
The built-in daily timer offers the convenience ofautomatically starting and stopping the system at settimes.
Setting addresses
ON
0 3 6 9 12 15 18 21 TimeThe indoor unit is set to work in automode from 8:00 to 20:00
SpecificationsModel I RM02 RM05 R05 l R06
1 IDimensions (HxWxD)(mm) 15Qx6Qx15 15Qx65x2Q 15Qx65x2Q 1QQx55x2Q
Power(V) 1.5V(LR03/AAA)x2
Besides the machine's auto addressing function,users can set the indoor unit's address onthe wireless remote controller.
R51 R71
14Qx6Qx15 1 125x42x27
GreenairINTERNATIONAL
Wired Controller11111
KJR-10B KJR-12B
*•...:; .o.t 0··-••~Ill G ~~-:,~; 'll'i "lil/OK
KJR-29B
Functions
Follow me
With the FOLLOW ME function, the wired controllercan detect the air temperature at the user's altitudeinstead of ceiling or floor. This helps makingthe room environment comfortable and thetemperature accurate.
FOLLOW ME Button /
*The follow me function is available for KJR-12B/KJR-29B model.
Remote signalreceiving function
Rem_otesignal KJR-29B provides a signalreceiving-------,receiver for wireless remote
Air filter cleaning controller. The signal is thenreminding icon
sent to the indoor unit.$-O:·-!: •t•....••~~8t C9-.J-;.;: ·~ 26°C shortcut setting26°C operation
shortcut keyKJR-29B(Touch-sytle key)
The optimum temperature forbalancing energy-saving andcomfort is 26 °c.
Easy connectionThe wired controller conveniently connects to theindoor unit's display panel via a connecting wire.
Air filter cleaningreminding
The air filter cleaning reminderfunction provided by KJR-1OB/KJR-29B/KJR-120A reminds users viathe wired controller when the filterof an indoor unit needs cleaning.
Locking wired controllerThe locking function can be used toprevent other people from using thecontroller.
KJR-108Wired controller
ODisplaypanel
Indoor main board
SpecificationsModel
--+--108 128 298
Dimensions (HxWxD)(mm) 12ox12ox15 12ox12ox15 12ox12ox20----
Power (V) DC5V
•
GAV-M5
Wired Controllernm
KJR-90A KJR-86C KJR-120A
Functions
Features•Basic functions are the same as KJR-108• Small and easy to install• Suitable for all types of indoor units• Can be stored in a mounting cabinet
Built-in timerThe built-in daily timer offers the convenience ofautomatically starting and stopping the system at set times.
KJR-90A
Mode-buttonhiddencontroller: Pressthe temperature buttons
".._" and "T" simultaneously for 3 seconds to select theoperation mode: COOL and HEAT. The design is suitable forhotels,hospitals, schools and other similar types of buildings
Mode Setting
26°C Shortcut setting
Selecting mode
KJR-86C
10°C heat function li!li
GAV-M5 controller: Under 10 °C heatoperating mode,whenthe room temperature is lower than 10°C, the wired controllercan open the heat mode automatically. When the roomtemperature is higherthan 15°C, then itwill stop heating.Thisis designed to ensure a comfortable and consistentenvironment.
10°Cheat function
KJR-120A
SpecificationsModel 90A 86C 120A
Dimensions (HxWxD)(mm) 9Qx86x13 86x86x18 12ox12ox15
Power01) DC5V
ID
GreenairINTERNATIONAL
Centralized Controller
COOL ModeII
With the PC orgateway communication
Indoor Centralized Controller
MD-CCM03 CCM30
Swing
HEAT Mode Wireless RemoteController LockKey Lock
Fan Mode Cooling Lock Heating Lock
FunctionsCentralized controlThe centralized controller is a multifunctionaldevice that can control up to 64 indoor units withina maximum connection length of 1,200m.The device connects to the master outdoor units ofGreen Air newly designed products to simplify andcentralize the wiring configuration. The twoconnection modes are as follows:
• - Ill Ill Ill----- ~-...• ,---\ ----"\- I .t I. '~~••••- --v-----\i---...,r---,-:,Q ~· '~~
Indoor unit working status displayThe centralized controller displays indoor units'working status and error codes so users can easilyidentify faults via checking the error codes table inthe user's manual before contacting a serviceengineer.
Error code orprotection code
Connectingstatus matrix
.!;!, WI' l1b I l!.1<2/Jllll<r GROUP QUERYlRUN SET •88 ~=L~~~~A~~FFP~~~~~TiB#MODE&• 11 12 13 04 15 OSE 00 • 11 11 12 13 1' 15 HiI~
- •II•11111111•11• 11111111•IIi!!~~'"'•II•11111111•11• 11111111•IROOM.TEMP SET.TEMP ,,..•II•11111111•11• 11111111•IBB~.::~~i~BB~.eJ?;oDD '" • 111•1111111111•11••1111111111•11•
~ lli!i liJ. f:IJii OPR.UNSUCCESS
Access to network monitoring
Three lock modesCentralized controller provides a superior way tomanage the indoor units. Users are able to maketheir own choice from locking the wireless controller,locking the running mode or lock the centralizedcontroller's keyboard as desired.
Air filter cleaning reminding functionThe air filter cleaning reminder function is onlyavailable on the touch-key central controller CCM30.The "FL" icon indicates that the air filter in a givenindoor unit needs cleaning.
Air filter cleaningreminding icon
CCM30
The centralized controller can bridge up to 64 indoor units on the network monitoring and building
SpecificationsModel I 179x119x74
MD-CCM03
Dimensions (ww•o)(mm)
Power (V)
CCM30
180x122x78
198-242V(50/60Hz)
•
GAV-M5
Centralized ControllerWeekly Schedule CentralizedControllerMD-CCM09
Auto Mode COOL Mode HEAT Mode Fan Mode
IJDRY Mode Sending query order Swing
11Key Lock
IICooling Lock Heating Lock WirelessRemoteWiththePCorgateway
ControllerLock communication
FunctionsWeekly scheduleMD-CCM09 can include up to 64 indoor units in theweekly schedule. Users can set up to 4 periods perday, and select the desired running mode and roomtemperature. The operating object can be a singleindoor unit or all the indoor units.
Three lock modesCentralized controller MD-CCM09 provides asuperior way to manage the indoor units. Users areable to make their own choice from locking thewireless controller, locking the running mode or lockthe MD-CCM09's keyboard as they wish.
Indoor unit working status display
Single/unified control modeThe control object can be either a single unit or allunits, which vastly simplifies the control process.Operation signal feedback ensures that all units areworking in the correct mode.
. ...
.......··...~ ...:
·····················'• '• .tJ; ·P
········ ········ 112~/············ =-
Connectingstatus matrix
MD-CCM09 displays indoor units' working status anderror codes so users can easily identify faults viachecking the error codes table in the user's manualbefore contacting a service engineer.
Error code orprotection code
88 #GROUPALL ERROR BB# MOOE€"'*1 " ., .... "" 06 17·•••• 11 " 12 1l ,. 15 1a:;1INLINE ON OFF PROTECT ~~ell :
ROOM.TEMP SET.TEMP w-
BB !: era <9~;.:8.' [JI; ,..ll.;'" '"Hr ON .., T2B '.t::I Hr '1J'o000
SpecificationsModel
Dimensions (H'W'D)(mm)
Power (V)
MD-CCM09
179x119x74
198-242V(50/60Hz)
GreenairINTERNATIONAL
Centralized Controller
Wired ControllerKJRF-180ANewly designed centralized controller controls up to 16indoor units and 1 heat pump water heater in addition.
Auto Mode COOL Mode DRY Mode HEAT Mode
FAN Mode Heat Water Lock
Functions
MultiQle machine controlKJRF-180A is a multi-functional device that cancontrol indoor air conditioners, heat pump waterheater, and fresh air units to realize the operation.
KJRF-180A
Stylish designKJRF-180A's stylish design suits high-endenvironments. The key lock function is used toprevent operational mistakes.
Single/unified controlKJRF-180A provides an easy way to controlindoor units and water heater. Users can quicklyselect the water heater or the fresh air units toadjust their running modes.
KJRF-180A
Easy installationKJRF-180A offers two different appearances tomostly suit the installation. Both of them are easy tooperate.
SpecificationsModel
Dimensions (WW.D)(mm)
Power (V)
KJRF-180A
180x122x69
220V(50/60Hz)
•
GAV-M5
Centralized Controller
Unified On/Off ControllerKJR-908Unified controller designed with graceful appearance and explicit panel.
A1e A2e •3e .•..•e•18 •28 838 B4flc18 c28 c38 c•e018 02(1 03(f o•8
~
Functions
Unified controlKJR-908 offers on/off and heating/coolingfunctionality for indoor units based on presettemperatures to ensure easy management. 11+11.. ~
·-· ~
Centralized controlKJR-908 can be used to centrally control up to 16 indoor units.
A18 A28 .ue M8B18 82. 83. Mfjtc18 c:i:8 c38 c•8D18 02. D38 04.
~
(§ill)I \
Light indicatorThe LEDs on KJR-908 indicate the indoor units' running status for easy fault detection. The lights switch offautomatically to save energy once a given operation is complete. The indicators are as follows:
Light Blue Red Flash
Single On/Off key
Unified On/Off key
Cooling/Fan ---L_ Heating IOU Error
L EEPROM Error
Easy installationKJR-908 can be easily mounted on the built-in cabinet:
SpecificationsModel KJR-908
Dimensions (H'W'D)(mm) 9Qx86x8
Power(V) DC5V
GreenairINTERNATIONAL
Central Control Software
IMG( Intelligent Manager of GreenAir)Monitoring System
FunctionsIntelligent Manager of Green air designed specifically to control VRF systems, is based on a centralized format anddedicated to the complete control and monitoring of all the system's functions. It can be used as a flexiblemulti-purpose system and applied to a variety of needs, according to the scale, purpose and control method ofeach building.
I •Up to 4 M-interfaces, 64 refrigerant systems,1,024 indoor units, and 256 outdoor units can becontrolled by one PC.
• WebAccess
• User friendly operation
• Centralized building monitoring and control
• Lock control (individual controllers)
\ • Set temperature limit
\• Proportional power distribution• Annual schedule control
• Low-load operation indicator
• Generate operational history reports(daily, weekly, monthly)
• Fault display & Warning message
• Filter replacement reminder
• Emergency stop and Alarm signal output
Network Control Application
'!IK'!f =! WebAccea•
ll!ilil!illll
Login interlace
tn+ !!-YI:~;~~~~;!!-~~I-·=-'==-===·=- -
• Can run on Window 7 32 bit andWindow XP 32 bit.
• Can monitor and control A/C anytime,anywhere by PC, phone, pad andnotebook computer.
• Support WEB access: IE, Firefox, Safariand Chrome.
• Enables remote access through DSL,VPNs and so on.
IMM software
GAV-M5
Various Managements
···-- •• ";Q '::Simple Operation and ManagementClick & Operate, a user-friendly interface allows even non-experts to performthe building management system easily.
Data Management
===: l!!!!!il!l@!l!I-!·--·•llilal!!I!!
Operational information of individual indoor units are monitored, allowing fordistribution of power consumption at outdoor units.Stores operation data on multiple systems and displays it in graphical format forvisual management.Uses IMG software to generate tenant reports and help building owners bill forenergy use.
Electricity Charge DistributionProvides information on proportional electrical power distribution to optimizeelectricity consumption management.
Uses software to calculate electric power proportional distribution, output and save electricity consumption data for each indoor unit (orgroup) which is connected to the intelligent manager.Applies the patented Green air Calculation Method to calculate consumption rates according to capacity demand which is based on variousparameters: setting temperature, room temperature, running mode, rated HP, public areas, unused rooms, and night time use; outputsthis information on a charge calculation sheet to evenly divide power consumption charges among tenants.
Hightlights
Web Access functionWith the web access function, a PC, laptop computeror a smart phone can be used as a remote controller.
Energy Saving ManagementBased on a predetermined schedule, the IntelligentManager executes capacity control and intermittentoperations on all air conditioning units to maintain ahigh comfort index.
Schedule ControlAutomatically performs facility start/stop control,switches the operating mode, sets temperatures andenables/disables the remote control according to thepresent time schedule. 4 sections and 20 actions perday for each single unit or group.
Warning MessageThe system can receive error messages from airconditioning units in more than one buildings orstructures via public phone lines.*Requires the Green air "SMS Modem" to sendautomatic warning messages to designated phonenumbers.
•I•mTrVisual NavigationClicking the jump button will display a list of allavailable screens. Clicking the back button will returnto the previous screen.
Data BackupThe M-interface will automatically back up data on theinstalled SD card (2GB) in case system failure occurs,such as: power failure or system dam. IMM softwarealso stores the previous 3 months' operational data onthe HOD.
Multiple LauguagesProvides eight language settings:
English
Russian
Simple Chinese
French Italian
German Spanish
Traditional Chinese
Electricity Charge DistributionElectricity charges can be easily divided when billingusers for air conditioning power charges; for example,for tenants in a commercial building, offices in a rentedbuilding, or rooms in a hotel.
GreenairINTERNATIONAL
AccessoriesBACnet® BMS GatewayMD-CCM08
Contains 4 groups of RS-485 communication ports and is able toconnect up to 256 indoor units or 128 outdoor units to the BMS.Be free to connect to the BMS or not.
Network example
Outdoor units
CCM02
Outdoor units
CCM03
RS485
BACnel/IP protocol
CCM03 Indoorunits
Monitoringsystem
BMS
Monitoring units onlineMD-CCM08 allows users to track units' operational status and change their running parameters on InternetExplorer for maximum control convenience
Wide compatibilityCCM08 has a wonderful adaptability to the BMS
Company BMS software Brand
1 SIMENS APOGEE~
2 TRANE Tracer Summit ~.ALCnlON'3 Honeywell Alerton
4 Schneider Andover
5 Johnson METASYS M~ SYS.
m
GAV-M5
AccessoriesModbus BMSGatewaySupports Modbus protocol networksBridges the Greenair central A/C system and the BMSEstablishes a Modbus network comprising up to 1,024 indoor units and 64outdoor unitsTransfers data in RTU modeProvides a wide voltage range: 12-48V DC
Network exampleIndoor Units
~. ~ ~ (Max.64) ~~-~-~ --------~/-- -- -- --
~Ill~ ~ (Max.64) ~~-~~- ~~~ --------~/ -- -- . -
llliDCCM03Modb:-i:-Gateway m
CCM02Modbus Master
CCM03-----r--Modbus \ C!!!-Gateway m
CCM02
( Max.16J
Outdoor Units
(Max.64) ~
--------~a~
One Modbus gateway can bridge one refrigerant system with a PC or the Modbus master.
Config A/C System via Web DimensionsOnce the Modbus network is set, users canconveniently configure their A/C network systemover the Internet using different TCP/IP browsers.
The Modbus Gateway is designed with a small size.It is equipped with an installation track for easy on-siteinstallation.
Login successfully
Usemame r~reena1r
Password r••••••
100
FrontSide
0000
0
:gm46
InstallationTrack
GreenairINTERNATIONAL
AccessoriesLonGW64® BMS GatewayMD-LonGW64The new Lonworks gateway has been complied with LonMark standard.It can connect up to 64 indoor units to the BMS.It realizes non-polarity communication and application can also bedownload online.
Network example
MD-LonGW64 ~=========:
I }
I II I
BMS system_;:----..!-----: RS485 II II II IIL------, r----\V/---,,/r-----..,
~ ~-·'RS485 II ---\;---, ,-----..,
~~ -0
SpecificationsModel
177-265VAC(50Hz/60Hz)
MD-LonGW64
Dimensions(H*W*D)(mm) 31.9X25.1X6.1
Power(V)
Hotel Card Key Interface ModuleMD-NIM05Cooperate with the wired controller to automate control.Eliminates the need for high voltage power, making the device safe andsteady.Includes a build-in auto-restart function.
,.,•.......• •..
Installation example Electrical wiring
~~ IKJR-108 I__ KJR-108 EC'>_•-r ·;--= -. -· I-•~ ---- MD-NIMOS -- MD-NIM05rt=-J I
Card key
Wiredcontrolleris necessaryin thiscard-keysystem.
~CLc.-T-~Card key u-'~ .,MD-NIM05
AC contactor
SpecificationsModel MD-NIM05
Dimensions(H*W*D)(mm) 86x72.8x15.5
PowerM DC5V
GAV-M5
Accessories3-Phase ProtectorHWUA/DPB71 CM48Detect the power condition and make the corresponding protecting action.Protect the compressor from being damaged.Automatically distinguish the abnormal power supply conditions and automaticallyrecover.
HWUA DPB71CM48
Excellent reliability
The protector protects the entire system from power supply problems, and auto restart after recovery.
Specifications
With over/under voltage function Without over/under voltage functionModel
HWUA DPA53CM23 HWUA DPB71CM48 DPA51CM44
Power supply (V-N-Hz) 220-480V-3N 50/60Hz 208-480V-3 N 50/60Hz 220-480V-3N 50/60Hz 380-480V-3N 50/60Hz 208-480V-3N 50/60Hz
Temp. range( "C) -zoc-sn50Hz: -20 C -60 C -2o·c-so·c -zo'c-so'c 50Hz: -20 'c-so 'cBOHz: -2o·c-so 'c BOHz: -zoc-so'o
Rated operational power(VA) 2.9VA 7VA 2.9VA 13VA 13VAOver voltage 12% 12% 18% 18%
Under voltage -12% -12% -12% -12% IPhase imbalance 8% I 8% 8%
Dimensions(WxHxD)(mm) 90x69x35 81x67.2x17.5 90x69x35 81x67x35 81x67.2x17.5
-Digital Power MeterDTS634/DTS636
Calculates power consumption.Does not need adjustment after long-term use.Corresponds one outdoor unit to one digital power meter.
Low power consumption Indications and installation
The digital power meter consumesminimal energy.Voltage circuit: less than2W/10VACurrent circuit: less than 2.SVA
16mmlangcrack The digital power meter is testedafter manufacturing so it can beimmediately deployed andused on-site. The LED indicatorsand installation schematic are
ol shown in the figure on the left.
Specifications
Dimensions (H*W*D)(mm)
DTS634/DTS636Model
23Qx145x72
PowerM 200V-500V(50/60Hz)
ID
GreenairINTERNATIONAL
AccessoriesOutdoor Centralized ControllerMD-CCM02 r 11;11
HEATlock COOLlock Withtheoutdoor With the PCorunitscommunication gatewaycommunication
ForcedCooling Low Middle High
FunctionsODU parameters displayMD-CCM02 enables users to easily check outdoor units' running status, including frequency, temperature,current, pressure, protection codes and error codes.
r ~~~~~~-~--~--~--~----~--~--~--~--~--~--~--~--~--~--~I ~ D rn=il QUERY SET 88#M.odule88#0u.tdoorunitlI • E:::J IQ_JJ Onlme ON Onlme ON :
MODE t:;;;-.,,,. ~ -=-•~ OFF Power(kWh) Freq(Hz) Indoor unit~""• "W ',,,, F~':1-:eayTemp'C Current(A) Digital Valve
f Fan 1 COMP 1 234 ST2 Error -088888.,.j~111 VALVE 1 2 a 4 5 6 1 a Protect-D •
Graph2 LCDScreen
Access to network monitoring~ ~
\
Model
198-242V(50/60Hz)
MD-CCM02
Dimensions(HxWxD)(mm) 12ox12ox15
Power(V)
GAV-M5
AccessoriesRemote Alarm ControllerKJR-328 I il,
.•Functions
Simple design
KJR-32B is specially designed for engineering applications. It does not display the ODU's working parameters,but it can connect to the alarm device when ODU is working abnormally, the RUN light will flash.
• Specifications
Dimensions (H*W"D)(mm)
KJR-328Model
150x85x70
Power(V) 198-242V(50/60Hz)
Indoor Unit Group ControllerKJR-150A I il
.•FunctionsSimple designKJR-150A is specially designed for GAV-M5indoor units. A group controller can connect up to 16 GAV-M5 indoorunits through X1 Y1 E, but it cannot directly connect to the central controller. If you need to use a central controller or a PC, you can connect to the XYE from an outdoor unit. A group controller can control a group of indoorunits simultaneously, and query the running status of each unit in the group via the display panel.System wiring diagram
M5+0utdoorUnlt
T'..........
KJR-150A ~2# GAV-M5indoor unil(1#) GAV-M5 indoor unit (2#) GAV-M5indoor unit (3#) ,.~-"··,...I POWER
-· Ii }" c; ~J "" 0 IZIIIIcq91 cq91 cq:r1 cq91 cq91 ----V-1 I NOTE..........
KJR-150A The Maximum NumberN#
GAV-MSindoor unit(1#) GAV-MSindoor unit (2#) GAV-MSindoor unit (3#} GAV-MSindoor unit N# (N:S:16) of Indoor units is 64.
-•·Jr Q ;,J "" 0cq91 cq91~ ~
cq91
Specifications
Dimensions (H*W"D)(mm)
KJR-328Model
150x85x70
Power(V) 198-242V(50/60Hz)
GreenairINTERNATIONAL
Accessories11111
HRVWired ControllerKJR-278
FunctionsHRV controller Built-in timerKJR-278 is individually designed for HRV-HeatRecovery Ventilator. The HRV can work in thefollowing modes: exhaust, air supply, bypass, heatexchange, and auto.
Built-in daily timer offers the convenience ofautomatically starting and stopping the HRV atthe set times.
AUTO->HEAT EXCHANGE->EXHAUST->8YPASS->AIR SUPPLY
Setup screen exampleSet to wednesday: 8:00 to 20:00
ON ~OFF>
0 3 6 9 12 15 18 21 Time
• SpecificationsModel
198-242V(50/60Hz)
KJR-278
Dimensions(HxWxD)(mm) 120x120x15
Power(V)
Mode Locking ControllerKJR-318
Functions
Running mode lockingKJR-31B can lock the running mode of theindoor units to avoid mis-operations and mode [COOconflicts.
Multiple device controlKJR-31B can lock the running mode of up to 64 indoor units.
~ (Max.64)___ ./ \~ =.J
v• SpecificationsModel
198-242V(50/60Hz)
KJR-318
Dimensions (H'W.D)(mm) 120x120x15
Power(V)
GAV-M5
AccessoriesControl BoxCE-AHUKZ-01/CE-AHUKZ-02GAV-M5 functions inside.Matches the new outdoor units.
IntroductionCE-AHUKZ-01/CE-AHUKZ-02 is an independent control box that can connect a AHU to GAV-M5 system torealize centralized control with GAV-M5 system. Control box wiring is as follows:
Centralized Controller
-- - - -.llj" --------
1~ •
..1~1-B F. I I
I I Wired Controller
••··-- -II••••'•'•'•!::::::::::::::::=~------- '4'®§l1'1J!4j
• Specifications
Dimensions(HxWxD)(mm) 485x395x205
Model CE-AHUKZ-01/CE-AHUKZ-02
Power(V) 198V-220V(50/60Hz)
GreenAir Outdoor Unit DiagnosisSoftware MCAC-DIAG/EDisplays the outdoor units' real-time running conditions.Automatically outputs running status charts.
:· ••••.• +"""""°""""""'"""'""'-
Wiring diagramThe diagnostic software applies to K1, K2,E of the outdoor units. The correspondingwiring diagram is shown in the figure on theright.
I K1,K2,EI
F ..
• Recommended config
HOD
WIN XP SP4/WIN 7Operating system
CPU Pentium 4 2G or above
30G free space
Interface port RS-232 terminal
GreenairINTERNATIONAL
GreenairCommercialAir Conditioning
ProjectContains project information such as project name,country, location, and detailed climate data to ensurethe optimum system is selected.
A/C selectionThere are15 types and100 models of indoor unitsand all kinds of different power of outdoor unitsto choose from.
Controller selectionProvides a selection of controllers for indoor units andoutdoor units, including wireless and remote controllers for indoor units.
Selection softwareTo meet consultants' and distributors' requirements,Green air has developed a new program for designingGAV-M5 systems. The software provides quick andconvenient selectable options for users, supportsmultiple languages, and greatly improves the selectionprocess.
Load calculationProvides two calculation methods: (1)Directly putthe room load, or; (2) Detailed parameters, includingroom area, estimated cooling/heating load index,heating capacity and cooling capacity.
Piping drawingDisplays the detailed layout of an A/C system andthe parameters for piping and branch distributors.
Report outputOutputs a comprehensive selection report as aWord or PDF document.
Calculate And Selection Result
AccessoriesGAV-M5
Model Feature
Branch joint of indoor unit I - I FQZHN-Q1C I 255x5Qx9Q/Q.48 I A*<16.6kW
Two-pipe refrigerant system -s--r -~- I I I For two outdoor unitsFQZHW-Q2N1C 455x55x 185/1.4
connectionrBranch joint for R41QA
outdoor unit I -r-= :;): I I I For three outdoor unitsFQZHW-Q3N1C 465x85x265/2.7(For two-pipe refrigerant r- ,,. connectionsystem)
-~- -~--~-r-:cm- r-s-..J-s-- For four outdoor unitsFQZHW-Q4N1C 465x115x255/4r r r connection
FQZHN-Q1C 255x5Qx9Q/Q.48 A*<16.6kW
-FQZHN-Q2C 28Qx5Qx95/Q.6 16.6SA*<33kW
Branch joint for R41QA 19 I x@i!J 3 -g
FQZHN-Q3C 31Qx7Qx125/Q.87 33kWSA*<66kWindoor unit
~FQZHN-Q4C 35Qx7Qx17Q/1.3 66kWSA*<92kW
-FQZHN-Q5C 365x 11Qx2Q5/1.6 92kWSA*
SBH-Q1For high static pressure duct type
Drain pump kit I ~ ljl~ I SBH-Q3indoor unit (Option)
SBH-Q4
Three-pipe refrigerant system
Branch joint of outdoor
unit
(For Three-pipe refrigerant
system)
Branch Joint of indoor side
(between MS box and
Outdoor unit. For
Three-pipe refrigerant
system)
A*:The total capacity of indoor units following this branch joint
Model namePacking Size (mm)/ DescriptionGross Weight (kg)
FQZHW-Q2S 465x65x 195/1.5 Connect the refrigerant
flow of different outdoor
FQZHW-Q3S 465x85x265/3.5 units
FQZHN-Q1S I 435x9Qx13Q/1.Q A*<16.6kW
FQZHN-Q2S I 435x9Qx 13Q/1.2 16.6SA*<33kW
FQZHN-Q3S I 58Qx8Qx155/2.1 33kWSA*<66kW
FQZHN-Q4S I 58Qx13Qx165/3.Q 66kWSA*<92kW
•
-n -n -n -n ~ Q0 0 0 0 ci, r-N N N N 0 &; _o·I I I I ~ c;z z z z O" Ill c:6 6 6 6 l ill in~... cc re en o c:(/) (/) (/) CD CD
"C c;·-;:;· o;·CD -I ,,....._,-.A I In·~A I
10:6.4
I
~ I~ lo j~[~0B="-}r ~~ r¥J~~ I~ 1· I~~~ fl
W: '2 I~I :;: ~ ~0 "' .•.
~ N"'dl:... 0
- ~- = cc
----+--
r-'.c·cc:"'c:CD
enc"s~Gl~"'c:CD
I<D"
-u
~roGl~"'c:CD
~- (/)c, c;
~- ~0 0s· ::J- "'Illin
~
c:;gro ~ w
~ ~
rtlilqu;cc~ - IC?
181~~ ~
~~~ l~l~gij'~1~~~q ~~lq 0:::I~;: ~ ()1 cc
Gl 0~ ~-in :T-· Illg- caQ: ro3.
0~
[fryo ~I": o ..co ~
fl~,,,,.
0<O
;aCD-h...,-·ccCD...,Q)::::J,-+0-·en,-+...,-·cc,-+0...,en
C)i:::»cu--·-1111\
GAV-M5
Outdoor branch drawingFQZHW-04N1CFQZHW-03N1C
I 00:31.8 10:31.8
FQZHW-02N1C
IOutdoorbranch I
00:31.8
10:31.8IO~:J I 00:31.8
01~
5)r:-I~ 00:31.8 Q1
I ILl.V"'t.;:>
z
I~
I~~ I 00:31.8
0
5
3
I~
CD:Jo§I
Q1ITT ~
c
Q':.'Cil
I
5r I~ 00:31.8
Gas side
lr"\.")J::A
S)l::"Q5~
Q1bfl ~II~ 00:31.8
Q1ITT ~00:34.9
I~
I~ 00:31.8I 10:25.4I10:34.9
Liquidside
Oil balancepipe
00:15.9IO;?J 10:15.9
Y110:15.9---110:12.7
10:15.9---110:12.7
00:15.9
10:15.9 10:15.9
00:25.4
~~
10:22.2
~~,r::::::i ~ Y8
~
Y110:15.9---110:12.7
Y1
Y1I~10:12.7
00:15.9
P(2pcs)
10:15.9---110:12.7
00:19.1
10:15.9
10:12.700:15.9
00:22.2
l~I0:~:1
p
-n0NI
-n
z0
6
N
ct
I
-n
o
z0
6
N
_..I
-n
o
z0
6
N
cc
I
-n I~o
z0
z
6
N III"'
N
3
o
zttl
~o
10:34.9L_J 10:34.9 I
I~ A I
10:44.5 I B=cu
I I
.2
I
g --·00:28.6 I I
8.6
Im\o
10:28.6
ill"'
1n..'"l'"l'"l
c:"a·5·u;
I I I 1~~.,0.0 I I I00:34.9 I I I 00:28.6
I -10:413 I I I 10:34.9 I 10:28.6
10:38.1 10:31.8
10:15.9 10:12.7 '
f10:6.4
10:9.510:9.5 H 10:6.4
10:12.7)(10:12.7) A
10:9.5 I 10:6.400:15.9 2.7
00:15.91 I 00:12.710:12.7 I 10:9.5
10:15.9
00:12.7
10:9.5
r-.g·c:(J)c:"'-0~
GAV-M5101-HM15