Performance Data & Specifications
Grease Pumps - Each Pump (V01 10,000psi W.P.)• Minimum Output Pressure 500psi (34.5Bar)• Maximum Output Pressure 12,000psi (827Bar)• Maximum Flow Rate 0.5lpm @ 10,000psi• Grease Capacity (usable) 450 litres• Max. Combined Grease Flow 1.5lpm @10,000psi
Grease Pumps - Each Pump (V02 15,000psi W.P.)• Minimum Output Pressure 500psi (34.5Bar)• Maximum Output Pressure 18,000psi (1241Bar)• Maximum Flow Rate 0.5lpm @ 15,000psi• Grease Capacity (usable) 450 litres• Max. Combined Grease Flow 2lpm @15,000psi
Hydraulic Pump - Pressure Compensated Axial Piston Pump• Max Pressure 3,300psi (228bar)• Displacement 45cc/rev• Hydraulic Tank Capacity 170 litres
Electrical Drive Motor 1 11kW 380-690V• Automatic multi voltage and automatic phase
correction.
Variant V01/V02:Upper Stuffing Box• Maximum Pressure 3,000psi (207Bar)
Lower Stuffing Box• Maximum Pressure 3,000psi (207Bar)
Tool Catcher• Maximum Pressure 3,000psi (207Bar)
Line Wiper• Maximum Pressure (pneumatic) 100psi (7Bar)
Power / External Supply
Air Supply• Minimum pressure 80psi (5.5Bar)• Maximum pressure 100psi (7Bar)• Volume requirements 30cfm
Electrical:• 380V-690V 50-60Hz three phase• 32A minimum supply connection• 220-240V 50-60Hz single phase• Automated multi voltage and phase correction
Design Standards
The grease injection unit will be designed using the following standards:• Machinery Directive 2006/42/EC. CE Marked• ATEX 95 (94/9/EC)• NORSOK D-002 System Requirements Well
Intervention Equipment• NORSOK Z-015 Temporary Equipment• DNV 2.7-1:2006 Offshore Containers.
BS EN12079:2006 Offshore Containers and Associated Lifting Sets.
Certification
• CE marked, ATEX Approved for use in a Category 2 (Zone 1) hazardous area
• Independently certified to DNV 2.7-1• NORSOK Approved
Performance Data & Specifications (cont.)
Sound Level• Maximum Operating Sound Level (outside of unit) 80dB(A)
Options
Variant V02:• 15,000 psi variant L-6901027709V02
Variant V03:• 10,000 psi variant L-6901027709V03Hydraulic Line Wiper• Maximum Pressure 3,000psi (207Bar)No Lower Suffing Box
Environmental Conditions
• Design Temperature range -20oC to +40oC, the hydraulic oil and grease grades must be chosen to suit the local environmental conditions.
• Weather resistant container with stainless steel construction.
This unit is a semi automated primary well control system for use in ATEX Zone 1 hazardous environments and in compliance with NORSOK regulations.
The unit features three grease intensifier pumps, control of the tool catcher, upper and lower stuffing box and line wiper.
Grease Injection Skid, NORSOK10,000 psi Well Pressure
Dimensions & Weights
PART NUMBER L-6901027709V01(L) 244 cm, 96 in (W) 175 cm, 69 in (H) 194 cm, 76 in (Maximum Gross Weight) 5,000 kg, 11,023 lbs
Primary hydraulic power is provided by an electrically driven pump.
Four modes of operation are provided, automatic grease injection based on wellpressure (patented NOV Elmar feature), remote automated grease pump control from a control room, automated grease pump control from a graphical interface on the unit and a fully manual operation panel.
The unit is mountedwithin a weather proofcontainer certified inaccordance withDNV 2.7-1 and BSEN12079. All controls,reels and tanks aremounted inside thecontainer behindsecure lockable doors.
Loading module into protective container
15,000 psi variant L-6901027709V02
N E S S I E
© 2014 National Oilwell Varco www.nov.com/Elmar
Elmar Product Line